Loading...
IPACHTE# 1 ~-:D- -;n 0NA Harnett County Department of Public Health Improvement Permit 26593 A building permit cannot be issued with only an Improvement Permit r PROPERTY LOCATION: Mc,~ pt~C.pst_t>sy ISSUED TO: W~Ie~tN c4 NA ;r% ct,VC.~ tits SUBDIVISION ,Y,mr-cv 1l iL LOT # I_ NEW; K REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: 5 G ® C "ll $ .x I ) Proposed Wastewater System Type: QS nt,cnltlrl S Em Projected Daily Flow: 3~n GPD Number of bedrooms: 3 Number of Occupants: max Basement ❑Yes "19 No Pump Required: ❑Yes 'No ❑ May be required based on final location and elevations of facilities Type of Water Suppl • ❑ Community X Public ❑ Well Distance from well ~ o O feet Permit valid for: Five years Permit conditions: ❑ No expiration Authorized State Agent:: ' The issuance of this permit by the Health Department in no way guarantees the issuance site is subject to revocation if the site plan, plat, or the intended use changes. The Impri the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit. Date: 011 ) SEE ATTACHED SITE SKETCH s. The permit holder is r sponsible for checking with appropriate governing bodies in meeting their requirements. This shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: CoNs-~c~vC,N o N PROPERTY LOCATION: Inc o v G~ ~4 SUBDIVISION CJv cc,-N LOT # facility Type: S'FQ ~~~'New ❑ Expansion ❑ Repair Basement? ❑ Yes A No Basement Fixtures? ❑ Yes "XNo Type of Wastewater System** QS-/0 S„- -V Lr ~ ® N SJ (Initial) Wastewater Flow: GPD (See note below, if applicable ~11 ZOUGA \ 0 N S J'5Tt-rn (Repair) Installation Requirements/Conditions Number of trenches 3 Septic Tank Size 1 O o gallons Pump Tank Size gallons Pump Requirements: ft. TDH vs. Conditions: Exact length of each trench 5 a Trenches shall be installed on contour at a Maximum Trench Depth of. alt-30 (Trench bottoms shall be level to +/-1/4" in all directions) GPM feet Trench Spacing: ! Feet on Center Soil Cover: ~a inches inches (Maximum soil cover shall not exceed 36" above the trench bottom) Aggregate Depth: WATER LINES (INCLUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. inches below pipe inches above pipe inches total *If applicable: /understand the system type specified is different from the type speciped on the application. / accept the specifications of this permit. Owner/Legal Representative Signature: Date: This Construction Authorization is subject to rev 'f the site plan, plat, or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This Construction Authorization is s ompliance with rov ' he La d Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State Agent: S Date: X-2 1 1\ Authorization Expiration Date: a..t1 Department of Environment, Health and Natural Resources Division of Environmental Health On-Site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Applicant: Address: Date Evaluated: Proposed Facility: ®E"c Ny Design Flow (.1949): X60 Location of Site: Property Recorded: Water Supply: ublic❑ Individual ❑ Well Evaluation Method,'BAu er Boring ❑ Pit ❑ Cut Type of Wastewater: Sewage ❑ Industrial Process Sheet: Property ID: Lot File Code: Property Size: ❑ Spring ❑ Other ❑ Mixed P R O F I 1940 OIL MORPHOLOGY .1941 THER PROFILE FACTORS L E # Landscape Position/ Slope % Horizon Depth (In.) .1941 Structure/ Texture .1941 Consistence Mineralogy .1942 Soil Wetness/ Color 1943 Soil Depth (IN.) .1956 Sapro Class .1944 Restr Horiz Profile Class & LTAR Description Initial Systerry' Rep r System Other Factors (.1946): Site Classification (.1948): Available Space (.1945) Evaluated By:a System Ty e(s) °lo ys b Others Present: +5T^ Site LTAR