Loading...
IPACHTE#-,/-s' a~-78~ Harnett County Department of Public Health Improvement Permit 2 6 6 0 7 A building permit cannot be issued with only an Ir rovement Permit p PROPERTY LOCATION: , a<~ ~'a~s ca ~~~f• ISSUED TO 'syjx SUBDIVISION LOT # NEW 1 REPAIR 0 .~~EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: fn fy,L Proposed Wastewater System Type: rA ~Fr l } :c„Icq '%r A k-A , /c. Projected Daily flow: -;4 Y0 GPD Number of bedrooms: 0?1 Number of Occupants: z! max Basement ❑Yes ❑ No Pump Required: ❑Yes ❑ No [Aa be required based on final location and elevations of facilities Type of Water Supply: ❑ Community V Public ❑ Well Distance from well feet Permit valid for: Z Five years Permit conditions: ❑ No expiration Authorized State Agent:: 4 a ~6'ttJ Date: SEE ATTACHED SITE SKETCH The issuance of this permit by a Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: PROPERTY LOCATION: SUBDIVISION LOT # Facility Type: fit V F-1 New F-1 Expansion El Repair Basement? ❑ Yes 101o Basement Fixtures? ❑ Yes ❑ No C Type of Wastewater System** 4- J~' / f ~ C~, 41 J,L I-, /c (Initial) Wastewater Flow: oZ GPD (See note below, if applicable fZ 0,,:.t q fllul J-+ .,Ad Lv ~ U ~r f sale (Repair) Installation Requirements/Conditions Number of trenches Septic Tank Size /COO gallons Exact length of each trench 0 feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of- _ inches (Trench bottoms shall be level to +/-1/4" in all directions) Pump Requirements: ft. TDH vs. GPM Trench Spacing: feet on Center Soil Cover: C inches (Maximum soil cover shall not exceed 36" above the trench bottom) Aggregate Depth: inches below pipe inches above pipe inches total **If applicable: I understand the ,r s stem typ e speciped is different from the type Specified on the application. l accept the specifications of this permit. Owner/Legal Representative Signature: Date: This Construction Authorization is subiect to revocation if the site clan, slat, or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownershin of the site. This Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH +u Futhoed State Agent: r Date: G /f o t, a1~ Construction Authorization Expiration Date: 4 f/'J 14 s®C. WATER LINES (INCLUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. HTE# 1/- s-- kk"7 0 Permit # cZ k,4, k 0-7 Harnett County Department of Public Health Site Sketch Department of Environment, Health and Natural Resources Sheet: Divisica of EiMronmental Health • On-Site Wastewater Section Property ID: Lot SOMME EVALUATION File for ON-SITE WASTEWATERSVSTEM Code: Owner. Appticaat: Address: Date Evaluated: G Proposal Facility: Design Flow (.1949): Property Size: Location of Site: prorty~~. Water 8uppi l~C ❑ Individual ❑ Well ❑ Spring Evaluattoa Mct2lod: - ,9luger Boring ❑ pit Type of Wastewater: Sewage ❑ Industrial Process Mixed; P R O F. SOIL MORPHOL00Y 1 .1940 .1941 PROFIM FACTORI L Lambespr Hanzan .1941 9 PosiHad Depth .1941 .1941 Soil .t§43 A slope % (is) st uctmW Calwateace Web aw $cu Toxlurt MinanW Color IN. ❑ Other .1956 .1914 t' emi 94pre Re* Cloak CIA= Haas. ALl.MR S em Rap"tr system Other Factors (.1946) Site CIMOcadon (.1948)Pf Evaluated By:6 ~ - ? Othess prexnt:, 1JI-P l !-41 f 3 ITr NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WATER PROTECTION SECTION INNOVATIVE WASTEWATER SYSTEM APPROVAL INNOVATIVE WASTEWATER SYSTEM NO: IWWS-2010-1 Issued To: Dave Lentz Infiltrator Systems, Inc. PO Box 768 Old Saybrook, CT 06475 800-221-4436; Fax: 860-577-7001 www. infi ltratorsystems. com For: Infiltrator Quick4 Plus Standard Low Profile (LP) Chamber Approval Dates: May 21, 2010 In accordance with 15A NCAC 18A.1969, an application by Infiltrator Systems, Inc. of Old Saybrook, CT for approval of modifications to its previously approved chamber (gravel-less) nitrification trench system, and the conditions of approval thereof, has been reviewed. Infiltrator has demonstrated that the modified system, the Infiltrator Quick 4 Plus Standard LP model with a minimum of six inches of cover, will perform in a manner equal or superior to the system as previously approved by Innovative wastewater system approval No. IWWS-93-2-R11 and its successors. The Quick 4 Plus Standard LP model with a minimum of six inches of cover is therefore hereby approved with innovative status subject the conditions contained herein. 1. Permitting Prior to the installation of the approved Infiltrator chamber nitrification trench system at a site for which application is being made for an Improvement Permit or Construction Authorization or at a site for which an Improvement Permit or Construction Authorization has been previously issued for a system described in 15A NCAC 18A .1955, .1956, or .1957, the owner or authorized agent shall notify the local health department. The local health department shall issue an Improvement Permit or Construction Authorization or amend the previously issued Improvement Permit or Construction Authorization allowing for the use of the proposed innovative system upon a finding that all provisions of this approval and all other applicable rules shall be met. Use of the proposed innovative system and any conditions shall be described in the construction authorization or amended construction authorization, as applicable. Such information shall also be described on the operation permit to be issued upon the acceptable completion of the system installation. IWWS-2010-1 May 17, 2010 Page 2 of 6 II. System Description A. Minimum pretreatment by septic tank as required in 15A NCAC 18A .1952. B. The Quick4 Plus Standard LP unit consists of polypropylene arch-shaped injection molded chamber. The connected overall length of a Quick4 Plus Standard LP chamber is 4 feet. The chamber sidewall slope is approximately 20 degrees toward the chamber center or away from the trench sidewall. Twenty-five Quick4 Plus Standard LP chambers are approximately equal to 100 feet. Table I Infiltrator Chamber Dimensions Model Length Height Bottom Average Open Slotted Invert' Overall (in) Width Bottom Sidewall Height (ft) (in) Width (in) Height (in) (in) Quick4 Plus Standard LP 4 8.0 33.5 29.3 6.3 3.3 and (polypropylene) 9.0 Invert Height is for a 4-inch diameter Schedule 40 PVC Pipe C. Each chamber unit shall be permanently marked as follows: Quick4 Plus Standard LP. D. Each chamber unit is designed to mechanically interlock with the downstream chamber forming a complete nitrification trench that consists of an inlet plate or cap with a splash plate located below the inlet on the trench bottom and a solid end plate or cap to be located at the distal end of any chamber nitrification line. E. In addition to conventional use as an end cap, the Quick4 Plus All-in-One 8 Endcap and the Quick4 Plus Periscope pipe appurtenances can also be used as an accessory with the Quick4 Plus Standard LP chamber to decrease the turning radius of a chamber line, as a drop-box in serial distribution, and for mid-line distribution pipe entry and exit. The Quick4 Plus All-in-One 8 Endcap can be used in all applications where the Quick4 Plus Standard LP chamber may be utilized. III. Siting Criteria The Quick4 Plus Standard LP Infiltrator nitrification trench assemblies may be utilized on any site that one can use rock aggregate and pipe which meet the following criteria: A. Sites which are classified as Suitable or Provisionally Suitable for a conventional nitrification field system in accordance with 15A NCAC 18A .1948(a) or (b). IWWS-2010-1 May 17, 2010 Page 3 of 6 B. Sites which have been reclassified as Provisionally Suitable in accordance with 15A NCAC 18A .1 956(l), (2), (4), (5), and (6). C. Sites which meet the criteria for new or existing fill in accordance with 15A NCAC 18A .1957(b). The provisions of Rule .1957(b) are applicable whenever any portion of the chamber in an Infiltrator System extends into fill material. This reference to "fill material" applies to the site fill and not the backfill placed between the trench and the chamber sidewall. D. The required vertical separation shall be measured from the bottom edge of the chamber. E. Trench bottom depth shall not exceed 36 inches. IV. Infiltrator Chamber System Sizing A. The maximum long-term acceptance rate (LTAR) shall be as follows: Table II Textural Group LTAR (gpd/sq.ft.) Natural Soil Sa rolite Soil/Group I Sands 0.8- 1.0 0.6-0.8 (Sands) Loamy Sand 0.5-0.7 Soil Group II Sandy Loam 0 6 0 8 0.4-0.6 (Coarse Loams) Loam . - . 0.2-0.4 S il G III Silt Loam 0.1-0.3 o roup (Fine Loams) Other Fine 0.3-0.6 N.A. Loams Soil Group IV Clays 0.1-0.4 N.A. B. The LTAR shall be based on the most hydraulically limiting naturally occurring soil horizon within three feet of the ground surface or to a depth of one foot below trench bottom, whichever is deeper. C. To determine the total trench bottom area (ft) required the design daily sewage flow shall be divided by the applicable long-term acceptance rate shown in Table II above. D. Reductions in total trench bottom area shall not be granted for low profile chambers. E. The minimum area (without reduction) for a bed system shall be determined as required in 15A NCAC 18A .1955(d) except that the chambers shall be placed in rows next to each other. F. The available space requirements of Rule.] 945 shall be met, and this approved innovative system may be designated as the required replacement system. IWWS-2010-1 May 17, 2010 Page 4 of 6 V. Design and Installation Criteria A. The Infiltrator chamber system used in nitrification trenches shall be installed according to the minimum and maximum dimensions in Table IV. Table IV Infiltrator Installation Requirements (Depths Measured from Finished Grade) Maximum Minimum Maximum Minimum Minimum Model Trench Trench Trench Trench Soil Width Depth Depth Spacing Cover (in) (in) (in) (ft.o.c) (in) Quick4 Plus Standard LP 36 14 36 9 6 (polypropylene) B. The inlet to the Infiltrator chamber shall be in the uppermost portion of the specially prepared inlet panel ("end cap"). For dosed systems receiving effluent from a pump or siphon, manufacturer's installation procedures shall be followed, including provisions to dissipate inflow rate so as to minimize soil scouring and modifications that enable the presence and effectiveness of these provisions to be field-verified. C. The Quick4 Plus All-in-One 8 Endcap may be used as an accessory with the Quick4 Plus Standard LP chamber to decrease the turning radius of a chamber line, as a drop-box in serial distribution, and for mid-line distribution pipe entry and exit. The number of chambers in the chamber rows extending in opposite directions from the Quick4 Plus All-in-One 8 Endcap do not need to be equal. D. Backfill shall be placed between the trench and chamber sidewall to a minimum compacted (carefully walked in) height that is equal to the top of the chamber louvers. Chamber systems can be installed utilizing native soil backfill (Group I, 11, III, or IV). Backfill shall be free of trash or debris. The area adjacent to louvers shall be free of large (8"or greater) clods that do not break apart during the walk in procedure. The latest version of the manufacturer's installation procedure shall be followed. E. The Quick4 Plus Standard LP chamber model may be installed with a minimum compacted cover of 6 inches when the following conditions are met: 1. The person installing or constructing the system is certified (documented) by Infiltrator Systems, Inc. as specially trained and qualified to install the Quick4 Plus Standard LP chamber units with a minimum soil cover of 6 inches; 2. The person installing the Quick4 Plus Standard LP chamber system shall produce certification documentation upon the request by the State or local health department. 3. When installing the Quick4 Plus Standard LP chambers the installer shall carefully follow the manufacturer's installation guideline for shallow placement. 4. In Group I soils, with only 6 inches of cover, tracked equipment shall be used during Backfill as specified by the manufacturer's installation procedures. IWWS-2010-1 May 17, 2010 Page 5 of 6 Vehicular traffic or construction equipment may traverse the chamber system only during system installation. The load must be bridged over the trench so as not to disturb the chambers. The load may be bridged with a minimum of six inches of compacted soil cover over shallow chamber models and a minimum of 12 inches of compacted soil cover over other Infiltrator chamber models. F. Individual chamber trenches shall be constructed with ± t/2 inch of trench levelness from side-to- side and shall follow the contour of the ground surface elevation (uniform depth). Trenches shall be constructed with continuous interlocking chambers, without any dams, stepdowns or other water stops, with a plus or minus 1-inch tolerance of trench levelness for any linear contoured segment. G. Infiltrator systems installed on a sloping site may use distribution devices or stepdowns as described in 15A NCAC 18A .19550) and (1) when it is necessary to change level nitrification line segments from upper to lower elevations. For the Quick4 Plus Standard LP chamber, the Quick4 Plus All-In-One 8 Endcap and Quick4 Plus Periscope pipe appurtenances may be used as a stepdown by making the cross-over out of one of its pre-marked 3.3- or 9.0-inch-high ports. From the end cap, effluent is conveyed through a solid pipe segment installed on a positive downhill grade down to the next lower trench in series. For the Quick4 Plus Standard LP chamber, the pre- marked port on the top of the Quick4 Plus All-In-One 8 Endcap may be used to receive effluent from an upper trench by a cross-over pipe. Infiltrator's MultiPort Invert Adapter may also be used to change elevation between nitrification lines for the Quick4 model chambers. Stepdown installation details shall be in accordance with Infiltrator Systems North Carolina Design and Installation Manual. H. After installation of chambers in trench or bed configuration, a filter fabric barrier shall be installed to cover the chambers (except Quick4 models) if chambers are installed in uncompacted, fine or very fine uniform sand and at least one of the following conditions are present. 1. Installations are left uncovered and subject to a major rain event. 2. Systems are subject to not being sodded (or stabilized) in a timely manner after final cover-up has occurred. 3. The drainfield is not protected from surface drainage. The filter fabric shall be non-woven, weight 0.35 oz./s.y. to 1 oz./s.y., have apparent opening size (AOS) 20-30 U.S. Sieve (ASTM D-4571), or alternate with equal or better performance characteristics. An alternate fabric shall be approved in writing by the manufacturer on a case-by- case basis. 1. Manufacturer's installation instructions for the applicable Infiltrator system used in septic tank systems shall be followed except as required herein or 15A NCAC 18A .1900 et.seq. J. All Infiltrator chamber systems shall be installed by a contractor or installer appropriately certified in writing by the manufacturer. K. The Quick4 Plus Standard LP chamber system shall be installed only with the Infiltrator Quick4 Plus All-in-One 8 Endcap or Quick4 Plus 8 Endcap options at the ends of each chamber row. IWWS-2010-1 May 17, 2010 Page 6 of 6 VI. Operation, Maintenance and Monitoring Requirements The Infiltrator chamber system shall have a minimum classification as a Type III g system (other non- conventional trench systems) in accordance with Table V(a) of 15A NCAC 18A .1961(b). VII.Repair Systems The provisions of 15A NCAC 18A .1961(1) shall apply to the use of Infiltrator chamber systems for repairs to existing malfunctioning septic tank systems. Approved by: Date: Soil Scientist List Thomas J. Boyce POBox81 Pittsboro, NC 27312 919-868-8135 NC Licensed Soil Scientist #1241 NC Registered Sanitarian #1353 Hal Owen Hal Owen & Associates, Inc. P O Box 400 266 Old Coats Road Lillington, NC 27546 910-893-8743 Fax 910-893-3594 halowen(kintrstar.net NC Licensed Soil Scientist #1102 Michael D. Eaker Southern Soil & Environmental Assoc., Inc. P O Box 9321 Fayetteville, NC 28311 910-822-4540 or 919-567-3017 Fax 910-822-4540 meaker38510a aol.com NC Licensed Soil Scientist #1030 Neal C. Floyd Neal C. Floyd & Assoc., Inc. 7908 Audubon Drive Raleigh, NC 27615 919-422-6745 Fax 919-676-8395 NC Licensed Soil Scientist #1039 John R. Davis, Jr. LSS Soil Horizons, Inc. P O Box 1063 Youngsville, NC 27596 919-818-5087 mb 919-554-2363 fax soilhorizons (&gmail. com Karl Shaffer, L.S.S. 685 Sanford Road Pittsboro, NC 27312 919-542-5803 office 919-244-1984 cell kshafferAmindsgring.com