Loading...
IPAC RHTE# ~ Z66 Harnett County Department of Public Health Improvement Permit 26413 A building permit cannot be issued with only an Improvement Permit _ PROPERTY LOCATION 6/'/3/ AZ .fell 1--6 ISSUED TQ/d ¢J~csz/d SUBDIVISION _°,/b• r~ff~'r LOT # Z NEW L~ " REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: Proposed Wastewater System Type: 2-5011 Projected Daily Flow: GPD Number of bedrooms: Number of Occupants: max Basement ❑Yes No / Pump Required: ❑Yes No ❑ M5Ae required based on final location and elevations of facilities / Type of Water Supply: ❑ Community 21 Public ❑ Well Distance from well feet Permit valid for: 2 ,Five years Permit conditions: ❑ No expiration Authorized State A k - -I- / ' M .497t.7 Date: 2-11-11 SEE ATTACHED SITE SKETCH The issuance of this permit b he ealth Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation i e site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED T0: ~sslrl PROPERTY LOCATION`~z~ C~v~s SUBDIVISION LOT # Facility Type: ' l/New Expansion ❑ Repair Basement? ❑ Yes No Basement Fixtures? ❑ Yes EZ No Type of Wastewater System" 25% ~C P l (Initial) Wastewater Flow: 3~,c.) GPD (See note below, if applicable 2 5-4 6 Installation Requirements/Conditions Number o (trenches Septic Tank Size aft gallons Exact length of each trench /ZO feet Trench Spacing: Feet on Center Pump Tank Size gallons Trenches shall be installed on contour at a Soil Cover: inches Maximum Trench Depth of. Q C4 inches (Maximum soil cover shall not exceed (Trench bottoms shall be level to +/-1/4" 36" above the trench bottom) in all directions) Pump Requirements: ft. TDH vs. GPM Conditions: 4 inches below pipe Aggregate Depth: 7- inches above pipe / Z inches total WATER LINES (INCLUDING IRRIGATION) MUST BE ]OFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. **If applicable: /understand the system type specified is different from the type specified on the application. / accept the specifications of this permit. Owner/Legal Representative Signature: Date: This Construction Authorization is subject to revocation if the site plan, plat, or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State A Date: 7-1-7-11 L~l Construction Authorization Expiration Date: 2-1 -7 i 4o HTE# Z(- Z 1 , Permit # ®2 6 Li r 3 Harnett County Department of 11ablic Health Site Sketch f PROPERTY LOCATON:a 1.34,4r,- - %d7//M~-~ Z-) ISSUED TO: 7; 05 5- SUBDIVISION /f~s35cf i LOT # _ Authorized State t: d Date: Z- W did L"4- Department of Environment, Health and Natural Resources Sheet: Division of Environmental Health Property ID: On-Site Wastewater Section Lot SOILISTTE EVALUATION File €1: for ON-SITE WASTEWATER SYSTEM Code: Owner. Applicant: Address: Date Evaluated Proposed Facility: Design Flaw (.1949): Ptoperty Size: Location of Site: Property Recorded: Watet Supple; ❑ Public ❑ Individual ❑ Well ❑ Spring ❑ Other Evaluation Method: ❑ Auger Boring ❑ Pit Cut Type of Wastewater. ❑ Sewage ❑ Industrial Process Mixed P R O F SOIL MORPHOLOGY OTHER 1 L .1940 L d .1941 PROFtLB FACTOA3 E A .m mp Pori" Slope, % ~ Harizw Depth (In,) .1941 .h st W .1941 .1941 soil .1043 .1916 mmo ui u Texwe soil Condd=" Wet"Md Mineraio Color SOH Sapro QY e* Reatr A" C1 CIA" l L 0-zK , Clap Hail. A LTAA Ttl -t{ ,J~ r- rs S G' - yL G-ci Lai 16" 15C-If e 3®. Eksa pdoa Initial Repair Syetew Other Factors (.1946k Availabb Span , 1949 s step Site Ctassi$cadon (,1948X 9 d4= Typo(s) Evehwted B)r Site LTAR Others Prexnt: