FM REVIEW Harnett � ,, a rekThYtAACOUNTY ' *N ,`j Emergency Samosa Dapertnant tuORTR .CAROLINA. . ;.:. , ��I T'1 www.harmet•org Plan Review, Inspection and Permit Fees Application Number 08- 50021262 $150.00 ❑ Explosive Mat. (90 Days) $ 75.00 ❑ Explosive Mat. (72 Hrs) $ 25.00 ❑ Fireworks Public Display $ 35.00 ® Final Inspection $ 35.00 +2.00 per device n Fire Alarm Testing $ 35.00 + 2.00 per nozzle 1 1 Fixed Fire Suppression $ 25.00 ❑ Insecticide Fog /Fumigation $ 50.00 ❑ Pipe Test/UST /AGST $ 50.00 ® Plans up to 5000 ft $100.00 ❑ Plans 5001 ft to 10,000 ft $150.00 ❑ Plans 10,001 ft to 25,000 ft $250.00 n Plans 25,001 ft and over $ 35.00 + 2.00 per Head ❑ Sprinkler Certification Test $ 35.00 n Standpipe Testing $ 25.00 n Special Assembly $ 25.00 n Temporary Kiosks /Displays $ 25.00 n Tents, Canopies, Air Supported $ 50.00 n Tank Installation (charge for each tank) $ 50.00 n Tank Removal (charge for each tank) $ 85.00 Total n/a Total device/heads Michael L. Marti / 12/15/10 Code Enforceme • fficial Date Harnett "'� C O U t d T Y i f (r ) Eminency NORM CAROLINA 1' � •. wxn..hs+mn.ag December 15, 2010 Kasdy A Dawoud 1924 Quail Ridge Road 27609 Raleigh, NC King Tut 6242 US 401 South Bunnlevel, NC 28323 Application Number 08- 50021262 Mr. Dawoud, Thank you for submitting the plans for the store /grill. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other tire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 906.1 Fire Extinguishers o Fire extinguishers shall be placed in the clubhouse in such a manner so that placement of the extinguishers does not exceed a 50 foot travel distance. o The fire extinguishers provided shall have a minimum rating of 2A 5B:C and shall not be installed higher than 5 feet above the finished floor o A Class K extinguisher shall also be placed in the kitchen. • 505.1 Physical Address o The physical address of the building shall be posted in a conspicuous place so that it can be seen on approach from the road, access road, and /or parking lot. o The numbers used to make up the physical address shall be at least 5 inches in height. Harnett .!'.1,•:.,,.:*int4COUN TY '�' Emapawy Sartins Dapertment NORTH CAROLINA ir Air • 903 Sprinkler System. • A construction permit will be issued to the installer once detailed plans are supplied to the Fire Marshal's Office for review. o No construction may begin before a sprinkler system permit is given. This includes the lead in fire line for the riser. • 907.1.1 Duct Detectors. o The duct detectors (without the presence of a fire alarm system) shall activate a visible and an audible signal in an approved location. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identified as air duct detector trouble. o Access shall be provided to each detector for periodic inspection, maintenance, and testing. • 912.2 Location of Fire Hydrants o With respect to hydrants, driveways, buildings and landscaping, fire department connections shall be so located that fire apparatus and hose connected to supply the system will not obstruct access to the buildings for other fire apparatus. The location of fire department connections shall be approved. o All portions of the building shall be within 400' of a fire hydrant. Installation of a hydrant must accommodate the above requirement. • Fire Department Access o The fire department access shall extend to within 150 feet of all portions of the facility. o The fire department access road shall be of an unobstructed width of not less than 20 feet and shall have an unobstructed vertical clearance of not less the 13 feet 6 inches. o Fire Department Access must be provided at all times for the Fire Department Connections supplying the sprinkler system. • Fixed Fire Suppression o Plans shall be submitted for the fixed fire suppression system installed in the Type 1 hood in the deli. After reviewing the plans, the fire marshal's office will issue a permit for construction to begin on the hood system. • Fuel Dispensing o Plans shall be submitted for the fuel tanks, fuel piping, and fixed fire suppression system installed on the property. After reviewing the plans, the fire marshal's office will issue a permit for construction to begin on the hood system. n Harnett t A r31 U CA A N !T S NA - � F M Y �/V ) Emergency Services Dena Meant wrrrfiarnatt.mg • 506.1 Knox Box o A secure key box shall be installed on the new building that houses all keys to all the doors within the building in which the fire department would need access to in the event of an emergency. o A Knox Box will need to be installed on ALL buildings within the complex (7 buildings total). o Knox Box ID stickers shall be placed on all exterior doors in which entry to the building may be gained. o The box shall be mounted not to exceed 48 — 60 inches in height. o The basic model for the buildings should be at least a selection from the 3200 Series listed on the order form. Thank you again for submitting the plans for the store /grill. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office Again, thank you and we look forward to working with you during the construction period! Sincerely, Mic�Martin Deputy Fire Marshal