Loading...
INSPECTIONS PREPARED 6/22/10, 13:59:55 INSPECTION TICKET PAGE 63 Harnett County INSPECTOR: IVR DATE 6/23/10 ADDRESS . : 90405 *UNASSIGNED SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 0.3- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8X41 -8 3BDR 2.5BATH SDF WITH CRAWL FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6-2_, - 3-1 C fW -111A_ COMMENTS AND NOTES PREPARED 6/30/10, 14:20:48 INSPECTION TICKET PAGE 44 Harnett County INSPECTOR: IVR DATE 7/01/10 ADDRESS . : 90405 *UNASSIGNED SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8X41.8 3HDR 2.5BATH SDF WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP B103 01 7/01/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7-t - Z5 Ap -MK B113 01 7/01/10 TI R *BLDG WATER /DAMP PROOFING VRU #: 001948600 7-1 - ____ _? COMMENTS AND NOTES 6.` I� 0 9 `9eoo vC Oit(( y PREPARED 7/08/10, 14:48:51 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 7/09/10 ADDRESS . : 90405 *UNASSIGNED SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8X41.8 3BDR 2.5BATH SDF WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING? - SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP B103 01 7/01/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7/01/10 AP T /S: 07/01/2010 12:13 PM. MREARIC B113 01 7/01/10 MR R *BLDG _WATER/DAMP PROOFING VRU #: 001948600 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC A814 01 7/08/10 TI ADDRESS CONFIRMATION VRU #: 001950518 3105 02 7/09/10 TI R *OPEN FLOOR VRU #: 001951425 T` b.f-1- B105 01 7/09/10 TI R *OPEN FLOOR VRU #: 001951417 7/08/10 CA T /S: 07/08/2010 02:48 PM NTART COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 07 -09 -10 PERMIT # 10- 50024639 ADDRESS: vic Keith VIOLATIONS: 1. Install double joists under all parallel walls Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 7/12/10, 14:13:06 INSPECTION TICKET PAGE 47 Harnett County INSPECTOR: IVR DATE 7/13/10 ADDRESS . : 90405 *UNASSIGNED SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4M1. STRUCTURE: 000 000 31.8X41.8 3BDR 2.SBATH SDF WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE SFD SEPTIC - EXISTING - SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP B103 01 7/01/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC B113 01 7/01/10 MR R *BLDG WATER /DAMP PROOFING VRU #: 001948600 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC A814 01 7/08/10 TI ADDRESS CONFIRMATION VRU #: 001950518 B105 02 7/09/10 R *OPEN FLOOR VRU #: 001951425 7/09/10 ' T /S: 07/09/2010 12:30 PM MREARIC install double joists under parallel walls B105 01 7/09/10 TI R *OPEN FLOOR VRU #: 001951417 7/08/10 CA T /S: 07/08/2010 02:48 PM NTART 3105 03 7/13/10 TI R *OPEN FLOOR VRU #: 001952852 ? - fl - sd 4P N COMMENTS AND NOTES PREPARED 8/09/10, 14:00:48 INSPECTION TICKET PAGE 39 Harnett County INSPECTOR: IVR DATE 8 /10 /10 "`'ADDRESS" . : 227 VIC KEITH RD SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8X41.8 3BDR 2.5BATH SDF WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP B103 01 7/01/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC B113 01 7/01/10 MR R *BLDG WATER /DAMP PROOFING VRU #: 001948600 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC A814 01 7/08/10 FE ADDRESS CONFIRMATION VRU #: 001950518 7/14/10 AP T /S: 07/14/2010 02:04 PM FBURGESS 227 VIC KEITH RD SANFORD, NC 27332 LOT 3 8105 02 7/09/10 MR R *OPEN FLOOR VRU #: 001951425 7/09/10 DA T /S: 07/09/2010 12:30 PM MREARIC install double joists under parallel walls B105 01 7/09/10 TI R *OPEN FLOOR VRU #: 001951417 7/08/10 CA T /S: 07/08/2010 02:48 PM NTART B105 03 7/13/10 MR R *OPEN FLOOR VRU #: 001952852 7/13/10 AP T /S: 07/13/2010 01:35 PM MREARIC R425 01 8 /10 /10 'T2 FOUR TRADE ROUGH IN VRU #: 001966563 COMMENTS AND NOTES PREPARED 8/11/10, 14:04:26 INSPECTION TICKET PAGE 34 Harnett County INSPECTOR: IVR DATE 8/12/10 ADDRESS . : 227 VIC KEITH RD SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8E41.8 3BDR 2.5BATH SDF WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP B103 01 7/01/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC 8113 01 7/01/10 MR R *BLDG WATER /DAMP PROOFING VRU #: 001948600 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC A814 01 7/08/10 FB ADDRESS CONFIRMATION VRU #: 001950518 7/14/10 AP T /S: 07/14/2010 02:04 PM FBURGESS 227 VIC KEITH RD SANFORD, NC 27332 LOT 3 8105 02 7/09/10 MR R *OPEN FLOOR VRU #: 001951425 7/09/10 DA T /S: 07/09/2010 12:30 PM MREARIC install double joists under parallel walls B105 01 7/09/10 TI R *OPEN FLOOR VRU #: 001951417 7/08/10 CA T /S: 07/08/2010 02:48 PM NTART 8105 03 7/13/10 MR R *OPEN FLOOR VRU #: 001952852 7/13/10 AP T /S: 07/13/2010 01:35 PM MREARIC R425 01 8/10/10 FOUR TRADE ROUGH IN VRU #: 001966563 8/10/10 1. No test on plumbing 2. No mid story guides on plumbing lines 2 inch and smaller 3. toilet flanges shall be corrosion resistant 4. No insulation baffles 5. Cannot use aluminium flashing against cement. $50 re- inspection fee T /S: 08/10/2010 10:50 AM KSLATTUM T /S: 08/10/2010 10:55 AM KSLATTUM R425 02 /12/10 TI FOUR'TRADE ROUGH IN VRU #: 001968122 c� OP 's COMMENTS AND NOTES EPA E D . ^PREPARED `8%13/10, 14:04:02 INSPECTION TICKET PAGE 26 Harnett County INSPECTOR: IVR DATE 8/16/10 ADDRESS . : 227 VIC KEITH RD SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8X41.8 3BDR 2.5BATH SDF WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP B103 01 7/01/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC B113 01 7/01/10 MR R *BLDG WATER /DAMP PROOFING VRU #: 001948600 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC A814 01 7/08/10 - F13.ftwaxo ADDRESS CONFIRMATION - •VRUf #: 001950518 7/14/10 AP T /S: 07/14/2010 02:04 PM FBURGESS 227 VIC KEITH RD SANFORD, NC 27332 LOT 3 8105 02 7/09/10 MR R *OPEN FLOOR VRU #: 001951425 7/09/10 DA T /S: 07/09/2010 12:30 PM MREARIC install double joists under parallel walls B105 01 7/09/10 TI R *OPEN FLOOR VRU #: 001951417 7/08/10 CA T /S: 07/08/2010 02:48 PM NTART B105 03 7/13/10 MR R *OPEN FLOOR VRU #: 001952852 7/13/10 AP T /S: 07/13/2010 01:35 PM MREARIC R425 01 8 /10 /10 KS FOUR TRADE ROUGH IN VRU #: 001966563 8 /10 /10 DP 1. No test on plumbing 2. No mid story guides on plumbing lines 2 inch and smaller 3. toilet flanges shall be corrosion resistant 4. No insulation baffles 5. Cannot use aluminium flashing against cement. $50 re- inspection fee T /S: 08/10/2010 10:50 AM KSLATTUM T /S: 08/10/2010 10:55 AM KSLATTUM R425 02 8/12/10 FOUR TRADE ROUGH IN VRU #: 001968122 8/12/10 DP 1. Still missing mid story guides for plumbing drains /vents $50.00 re- inspection fee. Okay to side and insulate. T /S: 08/12/2010 12:06 PM DETAYLOR I129 01 $ 8 8 /16/10 ( T � - I .p �� R *INSULATION INSPECTION VRU #: 001969351 R125 01 8/16 10 ' TI ONE TRADE ROUGH IN VRU #: 001969344 8/12/10 CA This a reinspection on plumbing T /S: 08/12/2010 03:58 PM NTART R425 03 J/ TI_ �y FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001969369 C ^ T /S: 08/12/2010 03:57 PM NTART COMMENTS AND NOTES Harnett County INSPECTOR: IVR DATE 10/27/10 r. - s ADDRESS . : 227 VIC KEITH RD SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8X41.8 3BDR 2.5BATH SDP WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SPED REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP 2103 01 7/01/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC 8113 01 7/01/10 MR R *BLDG WATER /DAMP PROOFING VRU #: 001948600 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC A814 01 7/08/10 FB ADDRESS CONFIRMATION VRU #: 001950518 7/14/10 AP T /S: 07/14/2010 02:04 PM FBURGESS 227 VIC KEITH RD SANFORD, NC 27332 LOT 3 8105 02 7/09/10 MR R *OPEN FLOOR VRU #: 001951425 7/09/10 DA T /S: 07/09/2010 12:30 PM MREARIC install double joists under parallel walls B105 01 7/09/10 TI R *OPEN FLOOR VRU #: 001951417 7/08/10 CA T /S: 07/08/2010 02:48 PM NTART B105 03 7/13/10 MR R *OPEN FLOOR VRU #: 001952852 7/13/10 AP T /S: 07/13/2010 01:35 PM MREARIC R425 01 8/10/10 KS FOUR TRADE ROUGH IN VRU #: 001966563 8/10/10 DP 1. No test on plumbing 2. No mid story guides on plumbing lines 2 inch and smaller 3. toilet flanges shall be corrosion resistant 4. No insulation baffles 5. Cannot use aluminium flashing against cement. $50 re- inspection fee T /S: 08/10/2010 10:50 AM KSLATTUM T /S: 08/10/2010 10:55 AM KSLATTUM R425 02 8/12/10 DT FOUR TRADE ROUGH IN VRU #: 001968122 8/12/10 DP 1. Still missing mid story guides for plumbing drains /vents $50.00 re- inspection fee. Okay to side and insulate. T /S: 08/12/2010 12:06 PM DETAYLOR I129 01 8/16/10 DT R *INSULATION INSPECTION VRU #: 001969351 8/16/10 AP R125 01 8/16/10 TI ONE TRADE ROUGH IN VRU #: 001969344 8/12/10 CA This a reinspection on plumbing T /S: 08/12/2010 03:58 PM NTART R425 03 8/16/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001969369 8/16/10 AP T /S: 08/12/2010 03:57 PM NTART R429 01 10/27/10 TI FOUR TRADE FINAL VRU #: 001998707 plc% CONTINUED ONTO NEXT PAGE HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910 -893 -7525 DATE: 10 -27 -10 PERMIT # 10- 5004639 ADDRESS: 227 Vik Keith Rd. CORRECTIONS NEEDED: 1. The panel must have 36' of clearance out from panel and a minimum of 30' from either side of sideways clearance. 2. The drain vent is not finished above the master bath. 3. The blow -off line from the water heater cannot run uphill, (no trap allowed) 4. The dryer vent must have 12' of clearance to ground or a well installed 5. Caulk around all toilets at floor line 6. Re- inspection Fee $50 Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 10/28/10, 14:09:00 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 10/29/10 ADDRESS . : VIC KEITH RD SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 06/17/2010 10:50 AM VBROWN - - -- 27W, LEFT ON BUFFAOL LAKES RD, LEFT ON VIC KEITH RD, LOT ON LEFT 1/8 TO 1 /4MI. STRUCTURE: 000 000 31.8X41.8 3BDR 2.5BATH SDF WITH CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 6/23/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001944826 6/23/10 AP B103 01 7/01/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001948593 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC B113 01 7/01/10 MR R *BLDG WATER /DAMP PROOFING VRU #: 001948600 7/01/10 AP T /S: 07/01/2010 12:13 PM MREARIC A814 01 7/08/10 FB ADDRESS CONFIRMATION VRU #: 001950518 7/14/10 AP T /S: 07/14/2010 02:04 PM FBURGESS y/227 VIC KEITH RD SANFORD, NC 27332 LOT 3 B105 02 7/09/10 MR R *OPEN FLOOR VRU #: 001951425 7/09/10 DA T /S: 07/09/2010 12:30 PM MREARIC install double joists under parallel walls B105 01 7/09/10 TI R *OPEN FLOOR VRU #: 001951417 7/08/10 CA T /S: 07/08/2010 02:48 PM NTART 8105 03 7/13/10 MR R *OPEN FLOOR VRU #: 001952852 7/13/10 AP T /S: 07/13/2010 01:35 PM MREARIC R425 01 8/10/10 KS FOUR TRADE ROUGH IN VRU #: 001966563 8/10/10 DP 1. No test on plumbing 2. No mid story guides on plumbing lines 2 inch and smaller 3. toilet flanges shall be corrosion resistant 4. No insulation baffles 5. Cannot use aluminium flashing against cement. $50 re- inspection fee T /S: 08/10/2010 10:50 AM KSLATTUM T /S: 08/10/2010 10:55 AM KSLATTUM R425 02 8/12/10 DT FOUR TRADE ROUGH IN VRU #: 001968122 8/12/10 DP 1. Still missing mid story guides for plumbing drains /vents $50.00 re- inspection fee. Okay to side and insulate. T /S: 08/12/2010 12:06 PM DETAYLOR I129 01 8/16/10 DT R *INSULATION INSPECTION VRU #: 001969351 8/16/10 AP R125 01 8/16/10 TI ONE TRADE ROUGH IN VRU #: 001969344 8/12/10 CA This a reinspection on plumbing T /S: 08/12/2010 03:58 PM NTART R425 03 8/16/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001969369 8/16/10 AP T /S: 08/12/2010 03:57 PM NTART R429 01 10/27/10 MR FOUR TRADE FINAL VRU #: 001998707 CONTINUED ONTO NEXT PAGE PREPARED 10/28/10, 14:09:00 INSPECTION TICKET PAGE 19 Harnett : Cbunl�y INSPECTOR: IVR DATE 10/29/10 ADDRESS . :227 VIC KEITH RD SUBDIV: CONTRACTOR : CUSTOM CONTRACTING CORP PHONE : (919) 775 -1497 OWNER . . : WILLIAMS CATHY M PHONE : PARCEL . . : 03- 9587 -01- -0346- -38- APPL NUMBER: 10- 50024639 CP NEW RESIDENTIAL (SFD)" ". REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 10/27/10 0 T /S: 10/27/2010 12:14 PM MREARIC 1. panel does not have 36" of clearance in front or 30" from either side 2. drain vent ois not finished inattic over master bath blow -off line on water heater cannot be trapped dryer vent outlet must have 12' to grade or well -5_ caulk around all toilets at floor T /S: 10/28/2010 08:49 AM NTART R429 02 10/29/10 TI , ., � � FOUR TRADE FINAL VRU #: 001999986 ( p -I' to �3' COMMENTS AND NOTES B arr +..' `r.-n T- - j! r 'M1stT,t-fre+r 'v v ' tFA?r -.,., .. .y ' ;: {. •r-=. : 3 l 1: :' , , / - . , , , - , , , - , 4 . „ i .. 44 - .. .m„ . ,t , : . 01 . 1. i. . . ia. . 4 10„ . ,ia. Ars:, reh , A , ,,a.. _., , 44 St&St 4 4,,,„ ,4, County of Harnett -'" Building Inspections Department Planning Services , Certificate of ompliance:_s Occupancy: >c.., Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Hamett • County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: 1 Use Classification: R- 3 Permit Numbers Name: r:A 1 14y Lob /A r: 1,4,5 Building: /n • SaO 2. 19 0 Electrical: 1 , t F.y Address: 2 2 7 l// C ee i+Li Insulation: 0 / P 4 lumbing: ( 1 Mechanical: MFG Home: ,,, Date: / G.. 29 .. / a Building Official:° y /> C Rea „,t.� %1 c M ”. ' 77 v T1+.70 71