IPAC (2)HTE# c=s-~~~~o Harnett County Department of Public Health Improvement Permit 2 6 3 5 6 A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: NA y)! 55 ISSUED T0: ~,.aV!s7N "C-6 SUBDIVISION Laot7-y \ugjtNN~Tow LOT # j NEW,, REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: w<iG~I,("e~EU.ows~,QN1~h Proposed Wastewater System Type: 9yycy430 `2S%, ~6OUC1C\ON ~.I Nlwt%\coL-9 Projected Daily Flow: 110 50 GPD Number of bedrooms: - Number of Occupants: 350 max Basement ❑Yes No Pump Required:-'es ❑ No ❑ May be required based on final location and elevations of facilities Type of Water Supply: ❑ Community 'K Public ❑ Well Distance from well - l)n feet Permit valid for. Five years Permit conditions: ❑ No expiration Authorized State Agent:: 'tom ry~ 9M5 Date: \1\ 3 ] 1 a SEE ATTACHED SITE SKETCH The issuance of this permit by the Health Department in no way guarantees the issuan other permits. The permit holder is r ponsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: NQ-A6- Mso,\A ~y, Lu lrAS- n1 rA t~T2 PROPERTY LOCATION: NG~~tiJ Y 55 SUBDIVISION L-Acv'-C-uc a,%Nv~r Q LOT # 1 Facility Type: CrsytLt-,1CNo~~+owsHsP \lo,>~ New ❑ Expansion ❑ Repair Basement? ❑ Yes No Basement Fixtures? ❑ Yes No Type of Wastewater System** ~ucnPTo/Q 4nvc,~~ora w~ fRAN~~aL~ (Initial) Wastewater Flow: t050 GPD (See note below, if applicable _ Pu M4? % 0 COK 146T-4 f r-4 (Repair) see ~~ac F~ Q L6 s 6t.s V'vcL On-A\ N Installation Requirements/Conditions Number of trenches y\v~ AN0 MAN\cc,i-O Septic Tank Size 1'00 gallons Exact length of each trench feet Trench Spacing: Feet on Center Pump Tank Size ~~04 gallons Trenches shall be installed on contour at a Soil Cover. inches Maximum Trench Depth of inches (Maximum soil cover shall not exceed (Trench bottoms shall be level to +/-1/4" 36" above the trench bottom) in all directions) Pump Requirements: ft. TDH vs. GPM inches below pipe Aggregate Depth: inches above pipe Conditions: I-) \S PrCl1re'% C ~p,sg~ O~.r p, QQ49e50\L- 'VIidM aQp1-~CPVI'S Sofa inches total S- ,Er-,s~ pOw L~N~ ls`~a eciusgc~ P~aouf.,b "thy D"'P 14 ~,ELD WATER LINES (IN(LUDING IRRIGATION) MUST BE ]OFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. *If applicable: / understand the system type specified is dih`erent from the type specified on the app/ication. / accept the specilcations of this permlx Owner/legal Representative Signature: Date: This Construction Authorization is subject to revocation if the site plan, plat or the intended use changes. The Construction Authorization shall not he transferred when there is a rhnnoe in nwnor<hin of rho afo Thil Construction Authorization is subject to comphts,e A~ovision%<the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. V SEE ATTACHED SITE SKETCH Authorized State Agent: Z0\5 Date: 0 Authorization Expiration Date: 1~ H--AL OWEN & ASSOCIATES, INC. SOIL & ENVIRONMENTAL SCIENTISTS P.O. Box 400,266 Old Coats Road Lillington, NC 27546-0400 Phone (910) 893-8743 / Fax (910) 893-3594 www1mlowensoil.eom 30 September, 2010 Mr. James Peterkin Nehemiah Building Ministries P. O. Box 1269 Lillington, NC 27546 Reference: Septic System Design Nehemiah Building Ministries Church on Hwy. 55 near Coats Dear Mr. Peterkin, A site investigation has been conducted for the above referenced property to design an initial septic system for the proposed 350-seat church. The design daily flow is 1050 gallons per day (3 gallons/day/seat). This report represents my professional opinion but does not guarantee or represent permit approval for any lot by the local Health Department. The permit you receive from the Health Department may contain some modifications or amendments to our submitted design. Please carefully review your permit and adhere to all prescribed requirements. The initial septic system is proposed as 660 feet of unequal length 25% reduction status (1;Z Flow or chamber) drains utilizing a long term application rate of 0.4 gal/day/ft2. A pressure-manifold will be needed to distribute effluent to the six proposed drainIhm (see attached Design Specifications). The drainlines should be installed off contour with trench depths ranging from 18 to 26 inches below surface. The first line should start at 22.8 inches and shallow to 18 inches below surface. The second line should start at 24.5 inches and shallow to 18 inches below surface. The third line should start at 22.1 inches and shallow to 18 inches. The fourth line should start at 23.3 inches, will shallow to 18 in the middle, then deepen to 19 inches below surface at the end. The fifth line should start at 24.8 inches, will shallow to 18 inches in the middle, then deepen to 22 inches below surface. The sixth line should start at 18 inches, deepen to 24.2 inches, then shallow to 20.4 inches below surface. The septic tank should be sized to held at lust 1728 gallons of effluent 'T`he pump tank should have at least 1152 gallons capacity. So it is likely that an 1800 gallon septic tank and 1201 gallon pump tank will be used for this project. An additional 334 feet of drainline space is available in the same vicinity as the initial system. This area is not adequate to provide a full repair area but could be beneficial as partial repair area in the future. However, adequate space to more than 100% repair the initial system should it fail is available on the rear half of the property, across the creek (see map). Soil Science Investigations + Wetland Delineations, Permitting, and Consulting HAL OWEN & ASSOCIATES, INC. Potential septic systems drainlines have been demonstrated with various colored pin flags that are located on the lot. It is important that you do not disturb the septic system area It is recommended that a staked line or protective face be placed around the system to eliminate any potential damage to the soil or the layout of the system. This report and the attached septic system design information will need to be submitted to the County Health Department for review and the permitting process. I appreciate the opportunity to provide this service and hope to be allowed to assist you again in the future. If you have any questions or need additional information, please contact me at your convenience. Sincerely, *ee-04- Hal Owen Licensed Soil Scientist " lac AM* Soil Science Investigations • Wetland Deliretions, Permitting, and Consulting Oliver Tolksdorf From: halowen [halowen@earthlink.net] Sent: Thursday, October 28, 2010 9:14 AM To: Oliver Tolksdorf Subject: Nehemiah Ministries Attachments: _1028090903_001.pdf The underground electric line will be routed around the septic system. The attached septic system design has been modified to reflect this change. Hal Owen & Associates, Inc. PO Box 400, Ullington NC 27546 Phone: (910) 893-8743 Fax: 893-3594 www.halowensoil.com Nehamiah Building Ministries Onsite Wastewater Design Specifications # Bedrooms: 350-seat church Daily Flow (gpd): 1050 Initial System Repair System Pressure ManMd 6:6 6f3 ft 25%a redaetton drainfines' = - y„ dF K..r. 2C 1'1K - tn~lle-d off ontodr"'at 9 8 t0 26 ihches L:T Q4 gai~day/off Y y Y ` Lines flaoaed at site nn COF rtontarc Initial/ Repair Line # Color Drainline Length (ft) Field Line Length (ft) Relative Elevation (feet) (1) (2) (3) (4) (5) :fiat:`: 1 Y 99x57" 99_,1,7 = 99.17_ A-JnibaV: 2 815 ` 86' 99.,49 = 9910 99;03 =98:55 Inidal,~ 3 W 85 94 99-3-7 9&.68 98:99 . _..98.83= Cni 4 Y 110 114 ' 9913 98:82;;: ;19 -9 98`89: ° .`.Ittihal_-' 5 R : 140 . 145> -98.95 98.38 ;98:4,. "_98:9K 98.62 IniSat" 6 B : 180 195 9&23. 98:23_ 88:32._ -„:98.75' 98.43 7 Y ' 84 96:22 ;_"9 <99 95:98 8 R 110 95:39 9 B 93186 ; 93:95 93.95 Pump Tank: Benchmark concrete ad outside door 100 Jcwler I ~c~. = t--F. t' <IG{ ak Nehamiah Building Ministries Pressure Manifold Requirements idihrs aaw. Concrete arstw 6xoao~d sudstss lisquired 4' inspection scltHO P 31 sob" comma" >M 1 4~ saandaid bax °Oed pipa, baivaives .a • - 21" rn. ..w aabd vadi gbe d . 3w . tP'evelpd -h4)1= d"kq4v to RR 1 'j rr- depend an when il is located an theIotacar>junctknwith ;~4.rt a thslocatisnofthataoln and d>aiafiau concide, rani tid bax Clean" in vdv r gets vane bca in valve box % { ~Wddqpw sar~oid anchor 12* - dse® ttoeuoionbetivalves -hpp- hole pipe for tape P-W head pronwq is vat" bax pipe hum 17r rabbet a[ to $m lot to WL 3se dams a. deainFnas shaetfornuiebarofiaps. cleenoct inpelf box ge" vdra in Val" t= taps & pipe & Wart enduvel sd**M Pipe to drain pit. - Tip # 1 -2 3 4 5 6 F 4' SCH 40 PVC Mangold Size 1/rsc h 80 112"sa 40 10sch 40 3~ 80 3/4'sch 40 I%ch 80 flow (flPM) &48 7.11 7.11 10.10 1250 16.80 Une#(te q L1 (WM L2 (891tJ L3 L4 (110ft) L5 1401q L6 (180(01 Nwared By Hal Owen and Assoc s. by- PO Box 400. LiMngton. NC 27546 Ph (910) SM47431 F x 893-3584 8/2112010 Nehamiah Building Ministries Pressure Manifold Design Criteria AWjc Mail'ug Address: Ffef>emiah &dkWg Ades Phone it PIN: Permitll:: HTE# 08-5-1 SC S/D: Larry Tuditlgton Low: 1 Site Address: NC Hwy 55 # seats: 360-seat church Daly Flow. 1050 Sins (3 9aliseat) Septic Tank: 1728 gals Pump Tank: *MCD gallons LTAR: 0.4 WdW Effective (trench) LTAR: 0.53 gpd/sgft Absorption Area: 1969 sgft Linear Length: 656 ft TRENCHES Length (ft): see tap chart Depth (in): Stone Depth (in}: na SUPPLY LINE Length (ft)::: - 20'- Diameter: 2" sch 40 pvc MANIFOLD Length (ft): 4.5 Diameter. 4" sch 80 pvc Elevation: 100.57 # Taps. -6 Tap Configuration: bit. spacing, 1 sib of manifold Tap Chart LTAR * 5% 0.58 Lire Color Elevation Length(ft) Schedule per tap gpd Area gpdW 1 : Y 99.57 60,": 112"sch 80 5.48. 97.36 180 0.541 2 B 99.49 112"sch 40 7.11- _ 126.32 255 0.495 3-. w 99.17 85 117sch 40 7.11- 126.32 255 0.495 4: Y 99.13 110:' 3t4"sch 80 10.10 179.44 330 0.544 5. R 98.95 - ° 140: 314%ch 40 12:50 222.08 420 0.529 8 B 98.23 180::: 1"sch 80 16.80- 298.48 540 0.553 Total Drainline: 660 Calculations: Dose Volume: 301.69 Dose Pump Run Time (unit): Drawdown: 302 gall Pump Tank Elevation (ft): Friction Head: 5.61 Elevation Head: 7.77 Total Flow 59.10 Sq. Fool= 1980.00 gallons, with Pipe Volume at % 70 3.10 Daly Pump Run Time (min): 17.77 Dns divided by a3 gal/ itch = t3.1 inches 99.8 Pump Elevation (ft): 92.8 liam _ VVMWm Formula (use supply rune Wngth+70' for OWnp in pwV toliq Design Head: 2 Total Head: 15.38 feet Pump to Deliver: 59.10 gpm a 15.38 It stead NEMA 4X Simplex Control Panel with elapsed time meter, cycle counter, a udib4e and visible alarm, hand-off-automatic (hoa) switch, and pump out separate circuits is required. A septic filter is required. Floats to be determined by type of pump tank used. Pcssile Pumps Include: Goulds; Hydromatic: SPD Solt ~ WP) Zoeller. Pmpamd By. Hal Owen and Assodaias, Im PO Box 400, LW ngton. NC 27546 Ph (910) W-87431 Fx SW3594 W21/2010 Performance [11111 WhokmCde Products Page: 6130-1 Data Secdora Performance Data Dahxk April 2002 RPM: 3450 [discharge: 3" So ids: 3/4" Supersedes: January 2001 18--- 60 12 40 a 6 20 t- SPD100H 0L 01 1 1 1 1 I 1 1 1 I 1 1 1 1 1 Cwdy-Ul G.P.Q. 0 20 40 0 80 100 120 140 1 i DIWOOMW 0 2 4 4 120 8 140 &D 3.►& 1s.44 The curves rated maxknm perforrrance characteristics w W000*Q fWj load (Nameplate) horsepo%w AN pumps have a service factor of 12. Operation is reconwriended in the bounded area with operational point within the crave IhAt. Perform ve curves are based on actual tests with dear water at 70° F. and 1280 feet site elevation. Condnbns of service: GPM: MH: I HYDROMATIC" SPD100H SPD50H v a v a T v6' 96S _ f m oey~ 100 R/W N.C. VjWf 55 o _ n oI~ p oQV o10