IPACHTE# 1 0 SS-7
Harnett County Department of Public Health
Improvement Permit 2 6 2 9 2
A building permit cannon be issued with only an Improvement Perm
\ ROPERTY LOCATION: >rqV -.V- Q
ISSUED T0: _ ~L p,v f 5 d N t om 6 5 - SUBDIVISION 6&1 M&Z7V1 LPCE LOT # a
NEW> gREPAIR ❑ (PANSION ❑ Site Improvements required prior to Construction Authorization Issuance:
f.
Type of Structure: F p 5-6 coo
Proposed Wastewater System Type: F r Sys ~E N-1
Projected Daily Flow: L-N C:) GPD
Number of bedrooms: L-'s Number of Occupants: max
Basement ❑Yes 'KNo
Pump Required:`- Les ❑ No ❑ May be required based on final location and elevations of facilities
Type of Water Supply: ❑ Community X Public ❑ Well Distance from well 0 fe0 feet
Permit conditions:
Permit valid for.
Five years
❑ No expiration
Authorized State Agent:: Date: VO 16 SEE ATTACHED SITE SKETCH
The issuance of this permit by the Health Department in no way guarantees ~fm
f othe
r permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This
site is subject to revocation if the site plan, plat, or the intended use changes. ent Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of
the laws and Rules for Sewage Treatment and Disposal and to conditions of this permit..
Construction Authorization
(Required for Building Permit)
The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance
with the attached system layout
ISSUED TO: K~~+ ~~w~o:r ~artES PROPERTY LOCATION: ~EMEfl CQ-tE`:`-flcz._
SUBDIVISION 921 C--,, 'S QL-P, LOT #
Facility Type: S~ r.,Q / New ❑ Expansion ❑ Repair
Basement? El Yes No Basement Fixtures? F-1 Yes 'X No
Type of Wastewater System** S ~5 C 6 M (Initial) Wastewater Flow- GPD
(See note below, if applicable
~r ~
S-t 51 & n (Repair)
Installation Requirements/Conditions
Number of trenches
Septic Tank Size ► cs c>O gallons
Exact length of each trench feet
Pump Tank Size 0 gallons
Trenches shall be installed on contour at a
rj E E a p~ Lie\ G9
Maximum Trench Depth of: inches
,,5(irench bottoms shall be level to +/-1/4"
in all directions)
Pump Requirements: ft. TDH vs.
GPM
Trench Spacing: Feet on Center
Soil Cover. inches
(Maximum soil cover shall not exceed
36" above the trench bottom)
C Aggregate Depth:
p
onditionsri ~s ~t~,c~• ~ ~ 5 SL,p O N ~ \ SOP 05P~L, G s~-S
~,eet-crr.~:~ Sd~L C ,aaS~zr.a,~
WATER LINES (INCLUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA.
NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA.
inches below pipe
inches above pipe
inches total
**If applicable: /understand the system type specified is different from the type specified on the app/ication. / accept the rpecifcationr of this permit
Owner/Legal Representative Signature: Date:
This Construction Authorization is subject to r n if the site plan, plat, or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This
Construction Authorizaton is s 'ect to complianc nth t ons a Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH
Authorized State Agent: eC. Date: to S 1
Co on Authorization Expiration Date: t 0 S` ) S
SHEGI '~c»5
I~Ij,'j 6e PL
3-,w F'.11 -514-tr L
S-c 5r.
,L f4 -ow
r
i
i
w
%IZO
w 1
1
I I
lei
I
~ I
K« ~ TtwU-3, Idt
G,p '~,,,,ni .Gul c. ~t✓c
fN=qD.
f`
tof I
5waG< aC)e--5
Guideline For Design and Installation of Fill Systems with Conventional Trenches
Gra.'j
I 7lysffr~.~, of ChR,~1,~
1. Trench and Fill Specifications
- Soil Texture Group
ire &
ys ft.
- Length of Fill
1(10 gpd/sq. ft. - Acceptance Rate
y~ ~d
goo sq. ft
3. ~
770 ft.
3
9 0
Sewage Flow
- Trench Bottom
- Trench Width
- Total Trench Length
- Number of Trenches
- Length of each Trench
- Width of Fill
sf 3d sq. ft. - Total Fill Area
/57" in. - Depth of sand
»s cm yd.- Volume of Sand
Depth of Topsoil
SBS cu yd • Volume ofTopsoil
11. Site Preparation
1. Place flags at the 4 comers of the area to be filled designated on the improvement permit.
Failure to place fill in the permitted area may result in the fill having to be moved or the
permit revoked
2 Do not work when the site is wet Working on soil when wet can destroy soil structure
making the site unsuitable for a Construction Authorization.
3. Remove all above ground vegetation and root mat from area to be filled without removing
topsoil. Removal of soil can result in revocation of the permit:
4. Disk the area to be filled to a depth of b inches to break up root mat
M. Placement Of Fill
1. Add 3 to 4 inches of approved sand fill to area and disk again to thoroughly mix the original
soil and the fill. Approved sand fill is a sand or loamy sand.
2. Add more sand fill to achieve a uniform height of SD (see diagram} in the middle of the fill
area.
3. The fill shall be tapered from the top edge of the fill to the ground surface 2 feet from the
boundary of the fill area. The top edge of fill is located 5 feet from the proposed trenches.
s H 6 7-: 'S 3C., q-- 5
4. Six (6) inches of finer textured fill shall be placed over the sand fill and extend to the
boundary of the fill area Finer texture is necessary to establish a vegetative cover which will
prevent erosion of the fill. Fill used for cover shall bea sandy loam, loam, silt loam or sand
clay loam texture. See CD dimension of diagram. Side slope shall be. I to 4 except for site
with Soil Texture Group 1 which can have a side slope of I to 3.
5. Contact Health Department for inspection of fill before constructing trenches. A
Construction Authorization must be obtained before proceeding.
N. French Construction
1. The outside edge of any trench shall be 5 feet from the top of the side slope of the fill.
2. This system is designed with 3 trenches which are 10 It long and 3 ft wide.
Trenches must have a spacing of __.g._ & on centers.
3. Trench bottoms shall be no deeper than IS inches below finished grade of the fill.
4. Trench bottoms shall be constrmdod level.
5. Distribution boxes shall be located 5 feet from the top edge of the fill.
6. Call the Health Department for inspection after the trenches are finished.
V. Landscaping -
1. The fill must be shaped to shed surface water and "I be stabilized with grass or other
suitable cover to prevent erosion.
2. Vegetation must be maintained after established. Grass must be mowed.
3. Additional fill beyond what has already been specified maybe necessary to cover and
landscape around the septic tank.
4. Call the Health Department for inspection after landscaping is complete. The Operation
Permit allowing use of the system is issued at this time.
5~-iaG,, L., d,~= S
DIMENSIONS OF FILL SYSTEM
WT = ft
t t ~
1 I
I ~
1 1
LT_-L_ft
~ I
1 - 1
1 _ 1
t Le = ~FT
l ~
1 ~
1 CD = in' 1
1 `
WB . ys SS-_ 7 ft
DEFINITIONS
WT - width of top SS - side slope
LT - length of top SD - Band depth
WB - width of bottom CD - cover depth
LB - length of bottom
s~>F.C-,-N s o~- S -
Calculation of Fill Volume
Total volume of fill (TVF)
TVF = I (LT + LB) /Z X (WT + WB) /21 X TFD
(.1_FT. + &y FT.) /2 X ( 3i FT. + 05' l'T',) J X . ! 7_sFf.
_ jr CU. FT.
(DIVIDE BY 27 CU. FT. TO OBTAIN CU. YDS.)
s *145 s-CU. YDS.
Total volume of sand (TVS)
TVS=[(LT+LB -4)/2X(WT+WB-4)t2JXSD
_ [ oo Fr. + _ ,/y _FT. - 4) P2 X Fr. + FT. -4)/2]X ZS~T.
= ±~CU. FT.
(DIVIDE BY 27 CU. FT. TO OBTAIN CU. YDS.)
_ 17 f CU. YDS.
Total-volume of cover (TVC)
TVC = TVF - TVs
- _&j± CU. YD. - r? S' CU. YD.
= BP5'CU. YD.
Key to abreviations:
LT = length oftop
LB = length of bottom
WT = width of top
WB = width of bottom
TFD =total fill depth
=SD+CD
SD - sand depth
CD = cover depth