Loading...
Final Kidds Place Pistal Addition Decision PacketFINAL DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: KIDDS SHOOTING RANGE PISTAL PIT Development Type: COMMERCIAL SITE PLAN REVIEW Date: APRIL 23, 2014 The above referenced application  SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. : :   : : MAP SHOULD SHOW NC 42 (NOT NC HWY 42, NOT NC HIGHWAY 42 WEST) BUSINESS ADDRESS: 8753 NC 42 HOLLY SPRINGS, NC 27540 OWNER ADDRESS: 8755 NC 42 HOLLY SPRINGS, NC 27540  : : I’d recommend amending original site plan. Do you have the original drawing of the pit? Show all existing structures & their uses. Add note for BOA approval date & CUP # “Conditional Use Permit # BA-CU-30-13 approved October 14, 2013” Note the approval Conditions: Days & hrs of operation = 7 days a week, 9:00 a.m. – 9:00 p.m. Limited to hand guns of .45 cal or less No moving shooters or targets (static range) Max. of 8 shooters Limited to use of 1 acre of total site Add a note that states “All structure shall be constructed at least 50’ from property line.” Add a note that states “This development is within one mile of a Voluntary Agricultural District.” Note that this property is within the WS-IV district. Projects without curb and gutter system shall not exceed thirty-six percent (36%) built-upon area. Note amount of impervious surface. As per the UDO, please adhere to or add the following notes… Range shall be enclosed on two (2) sides by an earthen berm, stabilized using standard practices. Said berm shall be a minimum of 10 feet in height at a thickness that will not allow penetration of any projectiles fired on the range. Range target line shall be constructed to withstand the highest caliber weapons that will be shot on site, in accordance with The NRA Range Source Book. Required firing line shall be constructed to include baffles meeting the requirements of The NRA Range Source Book. Warning signs shall be posted along range boundaries, spaced not more than 100 feet apart. Signage shall announce the potential dangers and the presence of an active firing range utilizing highly visible colors. A range safety officer shall be present at all times during the use of live weapons. Vehicle and pedestrian travel shall not be permitted within the 300 feet restricted area while the range is active. Provide a copy of the approved NCDOT driveway permit. Or provide documentation that a d/w permit is not needed. Add owner certification. Example… As the owner of record, I hereby formally consent to the proposed development shown on this site plan and all regulations and requirements of the Harnett County ordinances. ______________________________________ Date Owner Signature   : : I’d recommend amending original site plan. Do you have the original drawing of the pit? Show all existing structures & their uses. Add note for BOA approval date & CUP # “Conditional Use Permit # BA-CU-30-13 approved October 14, 2013” Note the approval Conditions: Days & hrs of operation = 7 days a week, 9:00 a.m. – 9:00 p.m. Limited to hand guns of .45 cal or less No moving shooters or targets (static range) Max. of 8 shooters Limited to use of 1 acre of total site Add a note that states “All structure shall be constructed at least 50’ from property line.” Add a note that states “This development is within one mile of a Voluntary Agricultural District.” Note that this property is within the WS-IV district. Projects without curb and gutter system shall not exceed thirty-six percent (36%) built-upon area. Note amount of impervious surface. As per the UDO, please adhere to or add the following notes… Range shall be enclosed on two (2) sides by an earthen berm, stabilized using standard practices. Said berm shall be a minimum of 10 feet in height at a thickness that will not allow penetration of any projectiles fired on the range. Range target line shall be constructed to withstand the highest caliber weapons that will be shot on site, in accordance with The NRA Range Source Book. Required firing line shall be constructed to include baffles meeting the requirements of The NRA Range Source Book. Warning signs shall be posted along range boundaries, spaced not more than 100 feet apart. Signage shall announce the potential dangers and the presence of an active firing range utilizing highly visible colors. A range safety officer shall be present at all times during the use of live weapons. Vehicle and pedestrian travel shall not be permitted within the 300 feet restricted area while the range is active. Provide a copy of the approved NCDOT driveway permit. Or provide documentation that a d/w permit is not needed. Add owner certification. Example… As the owner of record, I hereby formally consent to the proposed development shown on this site plan and all regulations and requirements of the Harnett County ordinances. ______________________________________ Date Owner Signature  : : No additional services will be requested for this site. No additional plumbing will be needed for this site per owner.  : :   Engineering (910)893-7555 : Provide erosion control approval. Provide stormwater permit and application to state.   LONG RANGE CONDITIONS The following conditions must be satisfied Must meet all requirements set forth by NC DENR. Contact at (910)433-3300.  : Please visit www.harnett.org/utilities for more information on the approval process.  :   :   :   :     Development Review Board Chairman   A FINAL copy, consisting of any corrections, etc., will be sent after the meeting. Upon resubmittal, additional comments/ corrections may be required. **Please remember all applicable fee’s** If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2) business days. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait, as all DRB members will have to review the plat/plan for compliance. If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Wednesday following the meeting the application was put on hold. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options.