Loading...
IPAC R4TE#3 1-i Harnett County Department of Public Health J Improvement Permit A building permit cannot be issued with only a Improvemen Permit PROPERTY LOCATION: C. ISSUED TO: S IO V'Vs� —S G!„� LN G SUBDIVISION - Tczd7-5 agj. ! 92> Lvt=S° LOT # L, 3 NEW)< REPAIR ❑ E NSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: S 'L7 C`3b +� f-N Proposed Wastewater System Type: Vyc-R"T o —S r _ Projected Daily Flow: GPD Number of bedrooms: Number of Occupants: (0 max Basement ❑Yes XNo Pump RequiredYes ❑ No ❑ May be required based on final location and elevations of facilities Type of Water Supply: ❑ Community l Public ❑ Well Distance from well feet Permit valid for: five years Permit conditions: ❑ No expiration Authorized State Agent:: S Date: °) I a-)-I 1�) SEE ATTACHED SITE SKETCH The issuance of this permit by the Health Department in no way guarantees the issuance permits. The permit holder is resp Bible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement ermit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: 5C) V" S 1 - s c-j�N%, �rq C. PROPERTY LOCATION: 0 a c,.s SUBDIVISION 12�'rSas Lv LOT # Facility Type: _5�FD Cat ^ I New ❑ Expansion ❑ Repair Basement? ❑ Yes No Basement Fixtures? ❑ Yes No Type of Wastewater System ** P rn a D �Cfl ur--S-N 0 AJ (Initial) Wastewater Flow: >40 GPD (See note below, if applicable ❑) V z.>,- - Ct-i-\ UQ" (Repair) Installation Requirements /Conditions Number of trenches Septic Tank Size 1 epn Q gallons Exact length of each trench 3 17D® feet Trench Spacing: Feet on Center Pump Tank Size gallons Trenches shall be installed on contour at a Soil Cover: G inches Maximum Trench Depth of: \-I, inches (Maximum soil cover shall not exceed (Trench bottoms shall be level to +/ -1/4" 36" above the trench bottom) in all directions) Pump Requirements: ft. TDH vs. GPM Conditions: C.." OC" C.OqaL 9 011E —' —" 15 i Sta9 tJ Q-U4 05 DL— 'Ft inches below pipe Aggregate Depth: inches above pipe 4 ��u F- r&— Q, inches total WATER LINES (INCLUDING IRRIGATION) MUST BE 10FT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. * *If applicable: / understand the system type specified is different from the type specified on the application. / accept the specifications of this permit. Owner /Legal Representative Signature: Date: This Construction Authorization is subI Ngjevocation i site plan, plat, or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This Construction Authorization ' t to complia ns of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State Agent: Date: °t struction Authorization Expiration Date: HTE# Permit # Q'� -3� M a,-)3' 1 T11", 6s-, M- Southeastern Soil & Environmental Associates, Inc. w P.O. Box 9321 Fayetteville, NC 28311 Phone' 'Fax (910) 822 -4540 Email mike @southeasternsoil.com September 15, 2014 Harnett County Health Dept. 307 Cornelius Harnett Blvd. Lillington, NC 27546 Re: Hydraulic conductivity (Ksat) analysis for pretreatment (repair area), Fox Run Subdivision, Lot 43, Prairie Lane, Harnett County, North Carolina To whom it may concern, An evaluation of soil and hydraulic conductivity (Ksat) has been conducted on the aforementioned property. The purpose of the investigation was to determine soil absorption rates for a proposed pretreatment/drip irrigation repair septic system to serve a 3 bedroom single family residence. All ratings and determinations were made in accordance with "Laws and Rules for Sanitary Sewage Collection, Treatment, and Disposal, 15A NCAC 18A.1900". Soils remaining in the proposed repair area (after site disturbance /grading) consist of approximately 6 inches of a friable gravelly loamy sand underlain by a firm sandy clay loam to approximately 19 inches. Below 19 inches is a firm sandy clay loam BC horizon. This horizon extends to approximately 23 inches. Below 23 inches is a firm to very firm mixed mottled sandy clay loam C horizon that extends to at least 48 inches. Two compact constant head permeameter (CCHP) measurements were made to determine a Ksat rate at depths of 30 to 36 inches (C horizon). Measured Ksat rates were 0.25 and 0.35 cm/hr (see attached chart). This equates to 1.47 and 2.06 gpd /sq. ft. Using 10% of the lowest Ksat measured (C horizon) equates to 0.147 gpd /sq. ft. (typical for domestic disposal without pretreatment). Using pretreatment typically allows application rates to be increased up to 100 percent (or 0.294 gpd/sq. ft.). The proposed repair system (drip irrigation with pretreatment) is based on a 0.15 gpd/sq. ft. (drip rate; equates to 0.3 gpd /sq. ft. conventional rate) application rate which is considerably less than the measured rate. In fact, the proposed rate is only about 10% of the slowest measured rate and should easily allow for sufficient drainage from the SOILISITE EVALUATION • SOIL PHYSICAL ANALYSIS, LAND USEiSUBDIVISION PLANNING + WETLANDS GROUNDWATER DRAINAGE /MOUNDING «SURFACE?SUBSURFACE WASTE TREATMENT SYSTEMS, EVALUATION & DESIGN proposed repair system. The Ksat measurements support a higher application rate if needed, however, for the purposes of a preliminary proposal we will use the more conservative figure. The system sizing is as follows: 360 gpd @ 0.15 gpd/sq. ft. = 2400 sq.ft 2400 sq.ft / 2 = 1200 linear feet of drip line spaced on 2 foot centers. Area available for drip field = +/- 5000 sq.ft. It is imperative that no additional grading, rutting, etc. occur in the area of the proposed drip field (see map). I trust this is the information required at this time. Please call if you have any questions. Sincerely, Mike Eaker President SOIL C il_ D. SOUTHEASTERN SOIL & ENVIRONMENTAL ASSOC., INC. DISTRIBUTION BENCHMARK NO. BEDROOMS LINE FLAG COLOR ELEVATION DISTRIBUTION —r4P LOCATION T-pe-A WA114 A- VAtME PROPOSED LTAR P. � GI Fr t— LENGTH (FT) TYPICAL PROFILE � DATE 0?12otor I —7954—e,- -,Yff,441— 6t' Alc) AIIM-ff M4 /1101-f 4-1ery ;ex /Z-