INSPECTIONS PREPARED 3/08/10, .13:58:54 INSPECTION TICKET PAGE 65
Harnett County INSPECTOR: IVR DATE 3/09/10
ADDRESS : 60 TURNER MATTHEW CT SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . : AMERICAN HOMESMITH LLC #14 PHONE :
PARCEL . 01 -0514- - -0002- -14-
APPL NUMBER: 10- 50023858 CP NEW RESIDENTIAL (SFD)
DIRECTIONS T /S: 02/26/2010 11:30 AM DJOHNSON --
CHANDLERS RIDGE LOT 14
60 TURNER MATTHEW COURT
210 SOUTH TO RIGHT ONTO OVERHILLS RD
THEN RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 43X40 3BR SLAB ATT GARAGE, PATIO, PORCH
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 3/_ 0 /10 TI R *PLUMB UNDER SLAB VRU #: 001892330
/f /€ CPO (
CO NTS AND NOTES
PREPARED 3/16/10, 9:45:33 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 3/16/10
ADDRESS . : 60 TURNER MATTHEW CT SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #14 PHONE :
PARCEL . . : 01 -0514- - -0002- -14-
APPL NUMBER: 10- 50023858 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:30 AM DJOHNSON --
CHANDLERS RIDGE LOT 14
60 TURNER MATTHEW COURT
210 SOUTH TO RIGHT ONTO OVERHILLS RD
THEN RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 43X40 3BR SLAB ATT GARAGE, PATIO, PORCH
FLOOD ZONE • FLOOD ZONE X .
# BEDROOMS 3.00 PROPOSED USE - SFD
SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 3/09/10 JH R *PLUMB UNDER SLAB VRU #: 001892330
3/09/10 AP t -pole passed
R125 01 3/16/10 JH ONE TRADE ROUGH IN VRU #: 001895033
3/16/10 CA
B125 01 3/16/10 n TI R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001895457
3' —I -fo ,4 T /S: 03/16/2010 09:44 AM JBROCK
COMMENTS AND NOTES
REScheck Software Version 4.3.0
Comp Cert
Project Title'HEMINGWAY
Energy Code: 2003 IECC
Location: LIIIIngton, North Carolina
Construction Type: Single Family
Glazing Area Percentage: 9%
Heating Degree Days: 3502
Construction Site: Owner /Agent: Designer /Contractor:
CHANDLERS RIDGE AMERICAN HOMESMITH AMERICAN HOMESMITH
LILLINGTON, NC RALEIGH, NC RALEIGH, NC
(:ornpliance Pas , . - r tr . - , - - -
Compliance: Maximum UA: 592 Your UA: 419
Gross Cavity Cont. Glazing UA
Assembly Area or R -Value R- Value or Door
Perimeter , 0-Factor
Ceiling 1: Flat Ceiling or Scissor Truss 1220 38.0 30.0 20
Wall 1: Wood Frame, 16" o.c. 360 13.0 10.0 15
Wall 2: Wood Frame, 16" o.c. 387 13.0 10.0 21
Wall 3: Wood Frame, 16" o.c. 180 13.0 10.0 10
Wall 4: Wood Frame, 16" o.c. 81 13.0 10.0 3
Wall 5: Wood Frame, 16" o.c. 180 13.0 10.0 7
Wall 6: Wood Frame, 16" o.c. 279 13.0 10.0 15
Wall 7: Wood Frame, 16" o.c. 360 13.0 10.0 17
Wall 8: Wood Frame, 16" o.c. 144 13.0 10.0 7
Wall 9: Wood Frame, 16" o.c. 126 13.0 10.0 5
Wall 10: Wood Frame, 16" o.c. 171 13.0 10.0 9
Wall 11: Wood Frame, 16" o.c. 189 13.0 10.0 8
Wall 12: Wood Frame, 16" o.c. 81 13.0 10.0 4
Wall 13: Wood Frame, 16" o.c. 63 13.0 10.0 3
Wall 14: Wood Frame, 16" o.c. 81 13.0 10.0 4
Window 1: Vinyl Frame:Double Pane with Low -E 9 0A80 4
Window 2: Vinyl Frame:Double Pane with Low-E 15 0.480 7
Window 3: Vinyl Frame:Double Pane with Low -E 15 0.480 7
Window 4: Vinyl Frame:Double Pane with Low-E 30 0.480 14
Window 5: Vinyl Frame:Double Pane with Low -E 15 0.480 7
Window 8: Vinyl Frame:Double Pane with Low-E 15 0.480 7
Window7: Vinyl Frame:Double Pans with Low-E 16 0.480 8
Window 8: Vinyl Frame:Double Pane with Low -E 15 0.480 7
Window 9: Vinyl Frame:Double Pane with Low -E 15 0.480 7
Window 10: Vinyl Frame:Double Pane with Low-E 15 0.480 7
Window 11: Vinyl Frame:Double Pane with Low-E 30 0.480 14
Door 2: Solid 21 0.500 11
Door 1: Glass 36 0.480 17
Door 3: Glass 24 0.480 12
Floor 1: Slab- On -Grade:Unheated 136 0.0 142
Insulation depth: 0.0'
Heat Pump 1: Air Some 7.7 HSPF, 13 SEER
Heat Pump 2: Air Source 7.7 HSPF, 13 SEER
Project Title: HEMINGWAY Report date: 10/27/09
Data filename: Untitled.rck Page 1 of 2
n �a
•
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application: The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.3.0 and to comply with the mandatory requirements listed in the REScheck Inspection Cheddist.
i
T vvii5 '7(V More_ SEA
N e -Title Sig -tore / D to
Project Title: HEMINGWAY Report date: 10/27/09
Data filename: Untitled.rck Page 2 of 2
i
f PREPARED04 /09/10, 14:02:24 INSPECTION TICKET PAGE 37
Harnett County INSPECTOR: IVR DATE 4/12/10.
ADDRESS . : 60 TURNER MATTHEW CT SUBDIV: CHANDLERS RIDGE 21LOTS
C : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER' . . : AMERICAN HOMESMITH LLC #14 PHONE :
PARCEL . : 01 -0514- - -0002- -14-
APPL NUMBER: 10- 50023858 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:30 AM DJOHNSON --
CHANDLERS RIDGE LOT 14
60 TURNER MATTHEW COURT
210 SOUTH TO RIGHT ONTO OVERHILLS RD
THEN RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 43X40 3BR SLAB ATT GARAGE, PATIO, PORCH
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 3/09/10 JH R *PLUMB UNDER SLAB VRU #: 001892330
3/09/10 AP t -pole passed
R125 01 3/16/10 JH ONE TRADE ROUGH IN VRU #: 001895033
3/16/10 CA
B125 01 3/16/10 JH R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001895457
3/16/10 AP T /S: 03/16/2010 09:44 AM JBROCK
R425 01 4/12/10 TI FOUR TRADE ROUGH IN VRU #: 001907994
COMMENTS AND NOTES
s•
Violation Notice
Do Not Remove
Harnett County Inspection Department
102 East Front St P.O. Box 65
Lillington, NC 27546
Phone (910) 893 -7525 Fax (910) 893 -2793
10- 50023858 April 12, 2010
1. Engineered plan calls for 8 jack studs each end of Ivl in garage.
2. Plan calls for Ivl over rear door. 2X10 installed.
3. Truss BOl missing one brace.
4. Leak at seal of master bathroom tub
5. Note. Install osb and simpson 170 brackets at insulation inspection.
Ken Slattum
Harnett County Code Official
l 7 r',
J.S.THOMPSON ,/4 P Is
ENGINEERING, INC P q t P� ' I °
structural and geotechnical •, - �
I - d
custom residential design - 4 1 f 1 J 1
.
■
October 16, 2009 I
.
Travis Webb I
American Homesmith LLC. l
PO Box 97365 I
Raleigh, NC 27624 I
1
Dear Mr. Webb:
Per your request, I have reviewed the 2009 edition of the North Carolina I
Residential Code to address the foundation anchor requirements and possible
alternatives for retrofitting additional anchor mechanisms.
Analysis revealed that for wind zones consistent with those of Harnett County,
'A" anchor bolts are to be installed ® 6' -0" o.c. and within 1'-0" from the end of
each plate. When retrofitting anchor bolts to achieve these minimum
requirements, the contractor may install 'h" threaded rods embedded a minimum
of seven inches into a masonry foundation and secured with epoxy, or if the , I
�-- - -` :foundation is a poured concrete wall or monoslab foundation, the contractor
may install /" x 6" expansion sleeve anchors such as "Red Heads ".
Please call me if you have any questions.
Sincerely,
J.S. Thompson Engineering, Inc.
N.C. License No. C -1733
,A e P '
•'
Jeffrey B. Whitson, P.E. SEAL
re ars a .
in P�
/0/16/09
606 Wade Avenue A
Raleigh, NC 27606
(919) 789 -9919 OFFICE /
(919) 789 -9921 FAX �' -_ _ _ e,
PREPARED 4/14/10, 13:59:27 INSPECTION TICKET PAGE ' 31
Harnett County INSPECTOR: IVR DATE 4/15/10
ADDRESS . : 60 TURNER MATTHEW CT SUBDIV: CHANDLERS RIDGE 21LOTS
.CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER' . . AMERICAN HOMESMITH LLC #14 PHONE :
PARCEL . . : 01 -0514- - -0002- -14-
APPL NUMBER: 10- 50023858 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:30 AM DJOHNSON --
CHANDLERS RIDGE LOT 14
60 TURNER MATTHEW COURT
210 SOUTH TO RIGHT ONTO OVERHILLS RD
THEN RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 43X40 3BR SLAB ATT GARAGE, PATIO, PORCH
FLOOD ZONE FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING • SEWER WATER SUPPLY COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 3/09/10 JH R *PLUMB UNDER SLAB VRU #: 001892330
3/09/10 AP t -pole passed
R125 01 3/16/10 JH ONE TRADE ROUGH IN VRU #: 001895033
3/16/10 CA
B125 01 3/16/10 JH R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001895457
3/16/10 AP T /S: 03/16/2010 09:44 AM JBROCK
R425 01 4/12/10 KS FOUR TRADE ROUGH IN VRU #: 001907994
4/12/10 DA 1. Engineered plans call for 8 studs each end of lvl in
garage.
2. Plan calls for lvl over rear door. 2x10 installed.
3. Truss B01 missing one brace.
4. Leak in master bath tub.
Note install osb and simpson brackets on garage wall for
inspection at insulation inspection.
T /S: 04/12/2010 01:25 PM KSLATTUM
R425 02 4/15/10 TI FOUR TRADE ROUGH IN VRU #: 001910150
9113110 Pe 1f
COMMENTS AND NOTES
PREPARED 4/16/10, 13:58:14 INSPECTION TICKET PAGE 28
Harnett County INSPECTOR: IVR DATE 4/19/10
ADDRESS . : 60 TURNER MATTHEW CT SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #14 PHONE :
PARCEL . . : 01 -0514- - -0002- -14-
APPL NUMBER: 10- 50023858 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:30 AM DJOHNSON --
CHANDLERS RIDGE LOT 14
60 TURNER MATTHEW COURT
210 SOUTH TO RIGHT ONTO OVERHILLS RD
THEN RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 43X40 3BR SLAB ATT GARAGE, PATIO, PORCH
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE - SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 3/09/10 JH R *PLUMB UNDER SLAB VRU #: 001892330
3/09/10 AP t -pole passed
R125 01 3/16/10 JH ONE TRADE ROUGH IN VRU #: 001895033
3/16/10 CA
B125 01 3/16/10 JH R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001895457
3/16/10 AP T /S: 03/16/2010 09:44 AM JBROCK
R425 01 4/12/10 KS FOUR TRADE ROUGH IN VRU #: 001907994
4/12/10 DA 1. Engineered plans call for 8 studs each end of lvl in
garage.
2. Plan calls for lvl over rear door. 2x10 installed.
3. Truss B01 missing one brace.
4. Leak in master bath tub.
Note install osb and simpson brackets on garage wall for
inspection at insulation inspection.
T /S: 04/12/2010 01:25 PM KSLATTUM
R425 02 4/15/10 DT FOUR TRADE ROUGH IN VRU #: 001910150
4/15/10 AP
I129 01 4/19/10 TI `; R *INSULATION INSPECTION VRU #: 001911658
1 /( (° A-P
COMMENTS AND NOTES
PREPARED 7/02/10, 14:09:14 INSPECTION TICKET PAGE 11
Harnett County INSPECTOR: IVR DATE 7/06 /10
ADDRESS . : 60 TURNER MATTHEW CT SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #14 PHONE :
PARCEL . . : 01 -0514- - -0002- -14-
APPL NUMBER: 10- 50023858 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:30 AM DJOHNSON --
CHANDLERS RIDGE LOT 14
60 TURNER MATTHEW COURT
210 SOUTH TO RIGHT ONTO OVERHILLS RD
THEN RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 43X40 3BR SLAB ATT GARAGE, PATIO, PORCH
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' - SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 3/09/10 JH R *PLUMB UNDER SLAB VRU #: 001892330
3/09/10 AP t -pole passed
R125 01 3/16/10 JH ONE TRADE ROUGH IN VRU #: 001895033
3/16/10 CA
B125 01 3/16/10 JH R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001895457
3/16/10 AP T /S: 03/16/2010 09:44 AM JBROCK
R425 01 4/12/10 KS FOUR TRADE ROUGH IN VRU #: 001907994
4/12/10 DA 1. Engineered plans call for 8 studs each end of lvl in
garage.
2. Plan calls for lvl over rear door. 2x10 installed.
3. Truss B01 missing one brace.
4. Leak in master bath tub.
Note install osb and simpson brackets on garage wall for
inspection at insulation inspection.
T /S: 04/12/2010 01:25 PM KSLATTUM
R425 02 4/15/10 DT FOUR TRADE ROUGH IN VRU #: 001910150
4/15/10 AP
I129 01 4/19/10 DT R *INSULATION INSPECTION VRU #: 001911658
4/19/10 AP
A814 01 4/21/10 FB ADDRESS CONFIRMATION VRU #: 001910908
4/19/10 AP / T /S: 04/19/2010 10:14 AM FBURGESS
/\/ 60 TURNER MATTHEW CT SPRING LAKE, NC 28390 LOT 14
R431 01 7/06/10 TI
� n46L+K FOUR TRADE FINAL >2500 VRU #: 001949805
COMMENTS AND NOTES
dF; ED 7/09/10, 15:16:01 INSPECTION TICKET PAGE 25
Harnett County INSPECTOR: IVR DATE 7/12/10
ADDRESS . : 60 TURNER MATTHEW CT SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH.LLC PHONE : (919) 422 -4128
OWNER . : AMERICAN HOMESMITH LLC #14 PHONE :
PARCEL . . : 01 -0514- - -0002- -14-
APPL NUMBER: 10- 50023858 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:30 AM DJOHNSON --
CHANDLERS RIDGE LOT 14
60 TURNER MATTHEW COURT
210 SOUTH TO RIGHT ONTO OVERHILLS RD
THEN RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 43X40 3BR SLAB ATT GARAGE, PATIO, PORCH
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 3/09/10 JH R *PLUMB UNDER SLAB VRU #: 001892330
3/09/10 AP t -pole passed
R125 01 3/16/10 JH ONE TRADE ROUGH IN VRU #: 001895033
3/16/10 CA
B125 01 3/16/10 JH R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001895457
3/16/10 AP T /S: 03/16/2010 09:44 AM JBROCK
R425 01 4/12/10 KS FOUR TRADE ROUGH IN VRU #: 001907994
4/12/10 DA 1. Engineered plans call for 8 studs each end of lvl in
garage.
2. Plan calls for lvl over rear door. 2x10 installed.
3. Truss B01 missing one brace.
4. Leak in master bath tub.
Note install osb and simpson brackets on garage wall for
inspection at insulation inspection.
T /S: 04/12/2010 01:25 PM KSLATTUM
R425 02 4/15/10 DT FOUR TRADE ROUGH IN VRU #: 001910150
4/15/10 AP
1129 01 4/19/10 DT R *INSULATION INSPECTION VRU #:. 001911658
4/19/10 AP
A814 01 4/21/10 FB ADDRESS CONFIRMATION VRU #: 001910908
4/19/10 AP T /S: 04/19/2010 10:14 AM FBURGESS
60 TURNER MATTHEW CT SPRING LAKE, NC 28390 LOT 14
R431 01 7/06/10 JH FOUR TRADE FINAL >2500 VRU #: 001949805
7/06/10 DA 1)Need R38 insulation in attic & markers per code. 2)8"
grade from nontreated wood.
R431 02 7/12/10 TI FOUR TRADE FINAL >2500 VRU #: 001952258
7 -J? -in
COMMENTS AND NOTES
th ` t t , ' tS A!,
County of Harnett
_ Building Inspections Department
`Plann>ng Services : -
Certificate of Comp O ccupancy: I
Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett
County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the
various ordinances of the Co amett and the North. Carolina State Building Codes. For the following:
Use Classification: _ Permit Numbers E°'
Name: Oti rI, c am n ntr fin . Building: &*41
' Electrical: ■
Address: D Y /n i I/.fr . • . Insulation: t 16
Plumbing:
Mechanical:
MFG Home:
Date: ._ / /3 _- i Building Official: Ti7%
fTPIC+TTT17"17‘7!%""'Hrl.'"1-