INSPECTIONS PREPARED 10/22/09, 13:59:08 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 10/23/09
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM P JACKSON PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -401S RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 I R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
LO1 2 V O 9
COMMENTS AND NOTES
PREPAREb,11 /19/09, 14:01:42 INSPECTION TICKET PAGE 5
Harin�tt &unty INSPECTOR: IVR DATE 11/20/09
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
,CONTRACTOR : WILLIAM P JACKSON PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -4015 RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE SFD.
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
II 1)A- 1)r
COMMENTS AND NOTES
S Harnett County - Edit Narrative e
Functions He •
FrJ 3ll3 {1
Application nmtsar, type 06 50019596 CP NEW RESIDENTIALISFD]
Property address - . 44 WILLIAM BETHUNE CT
Entire top of footer must be clean of debris, mortar, dirt
etc, so projection and bed joint can be properly inspected. •
T /S: 11/28/2e89 12:43 PM DETAYLOR ' •
•
•
I oK I 'Egli. j ° CWDei I tatill I Insert V Dilate I "'Sims stanlpl Sir defaults'
PREPARED 11/25/09, 14:01:14 INSPECTION TICKET PAGE 2
Ha..;_pettil County INSPECTOR: IVR DATE 11/30/09
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM P JACKSON PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -4015 RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE SFD
SEPTIC - EXISTING • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
B103 02 11/30/09 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
COMMENTS AND NOTES
S llarnett County - Edit Narrative fIJ
ructions
,rate b ii,9 I - 6 .V dTE - (11/3012009 23:51 AM
Application number, type 0550019596 CP NEW HESIDENTIALISFDI - Property address , 44 WILLIAM BETHUNE CT •
1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and _
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.80 re- inspection fee.
T/5: 11/30/2009 '
89:20 AM DETAYLOR
f a
•
•
OK (" . Emit I Cancel I _ COIN I, Insert I Delete I., Iime stamp User defaults •
PREPARED 12/07/09, 14:00:27 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 12/08/09
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM P JACKSON PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -4015 RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
3103 02 11/30/09 ■ R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 ® 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR
B103 03 12/08/09 TI R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001858877
1 1),V T /S: 12/07/2009 01:23 PM RDCONTE
COMMENTS AND NOTES
PREPARED 12/16/09, 13:59:20 INSPECTION TICKET PAGE 2
Hargett }ounty INSPECTOR: IVR DATE 12/17/09
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM P JACKSON PHONE : (910) 433 -4337
OWNER . . : BET BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -401S RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
3103 02 11/30/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 DP 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR
B103 03 12/08/09 T R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001858877
12/08/09 DA T /S: 12/07/2009 01:23 PM RDCONTE
Projection still not met.
T /S:. 12/08/2009 09:52 AM DETAYLOR
B103 04 12/17/09 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001862523
( / t5 ill 0i
COMMENTS AND NOTES
re ,1
3" MiN. H
5/8" REBAR
__ . -_
__ __ ER
8" ON CENTER
EXISTING
16" CONCRETE PROPOSED CONCRETE
FOOTING
FOOTING ADDITION
TOP VIEW
EXISTING 3" MIN. H H PROPOSED
16" CONCRETE 6" CONCRETE
FOOTING MEM FOOTING ADDITION
1-
• O
CROSS SECTION
,Q QQOF ESSI O A , - / :
SEAL =
021411 :•Lu;
t:
•,`�
OVCIr1EER '(�L�:
cyl l-, 6 : r):: ''.
-ideal V.
MICHAEL D. AVERETTE PE -4676
PROFESSIONAL ENGINEER
FOOTER DESIGN Averette Engineering Co., PA.
Established 1970
CIVIL ENGINEERING rrrr------��------------���� ---- A 712 E. Lake A7(11177 LAND SURVEYING /i Ridge Road
SITE: Lot 17 Carolina Oaks PLANNING Raeford, NC 28376
OWNER: Accent Home Builders ' i Phone: (910)488 -5656
Fax: (910) 488 -0181
SCALE: No Scale i L License: C -0146
W eb: ww w. a verette -eng. com .//
PREPARED 1/27/10, 13:58:45 INSPECTION TICKET PAGE 4
Harnett County INSPECTOR: IVR DATE 1/28/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BFT) PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18-401S RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING • NEW WATER SUPPLY UNKNOWN
c
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP )
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
B103 02. 11/30/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 DP 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR
B103 03 12/08/09 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17 :00 VRU #: 001858877
12/08/09 DA T /S: 12/07/2009 01:23 PM RDCONTE
Projection still not met.
T /S: 12/08/2009 09:52 AM DETAYLOR
8103 04 12/17/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001862523
12/17/09 AP
8105 01 1/28/10 TI R *OPEN FLOOR VRU #: 001876390
1-94-10 _ I
COMMENTS AND NOTES
PREPARED 2/24/10, 14:13:16 INSPECTION TICKET PAGE 3
Harnett County INSPECTOR: IVR DATE 2/25/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BFT) PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 0B- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -401S RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
8101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
8103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
B103 02 11/30/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 DP 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR
B103 03 12/08/09 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001858877
12/08/09 DA T /S: 12/07/2009 01:23 PM RDCONTE
Projection still not met.
T /S: 12/08/2009 09:52 AM DETAYLOR
13103 04 12/17/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001862523
12/17/09 AP
8105 01 1/28/10 JH R *OPEN FLOOR VRU #: 001876390
1/28/10 AP
R427 01 2/25/10 I FOUR TRADE ROUGH IN >2500 VRU #: 001886654
2 11( U
COMMENTS AND NOTES
PREPARLD 3/12/10, 13:58:59 INSPECTION TICKET PAGE 2
Harnett INSPECTOR: IVR DATE 3/15/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BFT) PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -401S RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE - SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
8103 02 11/30/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 DP 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR
3103 03 12/08/09 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001858877
12/08/09 DA T /S: 12/07/2009 01:23 PM RDCONTE
Projection still not met.
T /S: 12/08/2009 09:52 AM DETAYLOR
B103 04 12/17/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001862523
12/17/09 AP
8105 01 1/28/10 JH R *OPEN FLOOR VRU #: 001876390
1/28/10 AP
R427 01 2/25/10 • 172 TRADE ROUGH IN >2500 VRU #: 001886654
2/25/10 DA - lit Ladder frame all gables.
'r. Exhaust ducts for bath fans can't exceed 14 ft flex.
I,. Window within 24 inches of back door must be tempered.
)lC Need engineer repair for floor truss bored for water
lines above family room.
Need nail guard for shower water lines in master.
Vent in b/r 3 needs mid -story guide.
T /S: 02/25/2010 09:31 AM DETAYLOR
R427 02 3/15/10 TI FOUR TRADE ROUGH IN >2500 VRU #: 001894450
3- 6 -40 � . • . - - '
�r c r .n ', •01
COMMENTS AND NOTES
•
0 - e , - .
ITW Building Components Group, Inc.
1950 Marley Drive Haines City, FL 33844
Page 1 of 1 Document ID: ITZN8908Z0326113206
Truss Fabricator: Eastern Building Conponents
Job Identification: REPAIR / 49059RF - ACCENT NN
Truss Count: 1
Model Code: IRC
Truss Criteria: IRC2006 /TPI - 2002(511)
Engineering Software: Alpine Softaare,Version 9.04.
Minimum Design Loads: g - N/A
Floor - 55.0 PSF B 1.00 Duration
Wind - No Wind
Notes: Seal Date: 02/26/2010
1. Determination as to the suitability of these truss conponents for the
structure is the responsibility of the building designer /engineer of -Truss Design Engineer-
record, as defined in ANSI/TPI 1 Doug Fleming
2. As shoun on attached drawings; the drawing nunber is preceded by: HCUSR8908 1950 Marley Drive
Haines City, FL 33844
Details: STRBRIBR-
d Ref Description Drawing# Date
1 87576 - 405 10057009 02/26/10
•
•
•
•
•
•
•
•
Repair Charge: $27.50 per Custoner Agreenent.
Anuunt to be invoiced sop ly.
m >
CO W M
LL O g 0
\ u) n N
\ o m
o
N
i M m O En 01 on
m O
ra CO N m\ N 2
W T O c Li- r I-
k co r
'g - • m i 2 I
N
N r - ar E Lei W Q C U CO. C
CO O O 2 N 1
E - 6 ZWW
0 = C OQF LL LL LL LL LL
N an N N N
• ?F y a O. a a d
F Fa � -ra24a q - En ce 0 0 0 0 0 0 .
an 1.4 O 3 \ 0 0 In O N r N
e. real • n \ V N
m= m le v 7 • U z EEC - PSGHS CO
1- In
w ¢ in 2 U J C O J F - C 6
U U Z
u WGK w� •1 U U O O C
U H CO m 0 O N
• 0 1-\3= r O
U .21- I°. Y
o N 6- f- plwuuq,
g
l02 J Q �•� ��iim
• 2M000 M
301nC
SC52 V 0 - u yw >:
WO P.M W
X3 I O N :Y. Lid
S Y S p •
\ MI-0 i W .- VV�
2H =U N O
21 O •1
r
cr
W I- co r NM O
vfn 01-On %� T
G �
O 5'
0 a
1:411 0 07 0
n r \ I I $ g W" N 3Tg
CD O W r ce GSa w
iL u m SI M O z ° '� � $ Set$
Y c 3 m 3 _ .I . N ce O. O. _ €..
m II I5�
O IOh O w 1:. ^ to ° W e° w i
J • X N U u C I - L F 8g. ° < a
O 'V O � 1 V J a 1
Q M_ U N = 1 r re O C Y W W
0 y G L r z . 3 m � -
m co n c tit L. < 0 I t - ° Sc § 6 :: '
c � m a n ° - z No ll W
i e .
1 -L 4 UI C JLL M i a a .... . � z
O.a °
N 20 W i f °
L 9 N O O H X 1' '^ m "
0 N a w 0 N V1 < v 7 w y W E' D " > >°
CC ° o✓ m C 1n F d\ X $'e b oa=
J h
v m 0 n-0 � - W g _ X 5 GN _ :y w
ar m m L M a H tu Ea V l I %pi�$!g in>
J L O- n L Z N N O 1 • N ° W
0= O L Y1 O O cc O� _ J 1 5 5 _ r
J L CO ; ]a 00 O O Sy I II I-
CO � O O f C T N W LL 6' S � / 3 Q •
6n 2 - D W 0 O 0 EEC W i . m y e U' °m
3- a u turn u c�c . lii V V s u L,l @''
w L a - u a c .0 ufw m j Z i u"
u m 0 3 0 m n Ln
N. o N D co E O N Q _- 3 J t L' • C L H9 v Hm w LL Q O. a v
m .,+c L n z .. I E a
L I I
O m N N O L V I W N F O-C3 CD N a 20.' O J
O I - 0 2O 2 N N I-LL 2 1
•
c W _ c Y C
Nd S W WO d
W L O « O ..L. T � O .a a 00 o T ca 0
n _0 N a W e° U 7 W ' W a W a CJ 21
0 an 0 ,c : N W W >. E a c 2 n N a . o v\
c , � C c o 2:° c C N m «.. c L m L d 31 to Ta
y L In O c W �`
Y Q a O W W ` L, W � �� x
E o.c mm atu W �CW AN >.E 0
I I \ I c5
p c W Vl .O ❑ 0 E N a `, W L O O C i [ °
C a W W m m> c a ■ C a
.a di o0 d « m E m = °a) .4 c>, w Clq n
' W ) c o '° N W w M ,- W c> 1].) O o a W L 2- a. G_ C O.
-13 x — a c m W W W 4 ? E • W °$ W c •� c o (33
m n 'n v u -
o a- C W 0 O c t J h W c 0. 0.. 1: 0. a
a o N o. . O a , O 0 W r N d a c L v N
O, 0 O I y , y '° W o n L W - u W . in _
o o, c m ool oC j5o gy °gym �w on m._ c o c
N C ° C a m- 0 3 C O C C p , N O 0 9 .- N
D W L an U co a a , O. CO >, y al C 6 C y C U E 3 0 7 a U W N'C T.r O O N L U 01 O
W W Y oI W E b is D E L e m W m ° ,-, r C 2 c a s - Q e
dl'u ° c a W IL O En= m c W c a G- 7
co m•=clu ao 02. -20 c co o 0 a a F IX
N m a y O o W o Z - 0 L W ry W" a N .-cm m "c.42 U U U o .7 d
a E o .- m Q • Nc c t mm i `' mu' o Oi w E H F 17 17 F. Q V:
al W VI 01 t ° _0 c U o .. c m .. q C O W -0., o 2 '
„ W O . u ° No a ="c a ' O E °dW Cw
x o
$ a ° W N , , u ° v O v a m° E E W u E To En „ „ uu ° pl..
WY 0 .- NN- OC - W cY E0 c � „` ,
O_ a O O •, •
H a E = ' . .- m E�o dac oo ? '
W W W . _ 8 W E U h c W W T W W° O W in = E `3
Q O, H C C 0 F E v a 2 1- m !2 ° o d I- t m u! U . f u,rpp
O
- - - -- x
w
CCD u w - m ° i I c., In /2
z m _
Y
m
u n
1 /
f
i
e.
J / ✓
> L191 2 i 21-le Pe
Z E /' i w.% n O / / /i /� \ ' \�'� �a 0) g 9 - 2 9
E o f ° �_, \ \\ - \a\ \ / E ` -
Ce m w / 2 m t /� f ��� A ✓�l� // I - U
O 00 k V ! � / � �
m oo // m3 I t I \ \ Up v _ e -
z '- N -am a m m z _ _ =
O �2 x2 h hQ ! O � o mA / ti Z2 0,00,11/92/ � / W `> z.
w 10 \ x 2� / j J EC / e � —� S o
03 X1"1, /0 z w o w 6.'42'1'2 // y O t�
T l / \ 5 w o 0000„ / i. Q - a
— u� bo L 7� = G
// l� .0.7, gr U, Q6 =2� DZ Q : E
X Fr; �� � A 2 r \ Z K /��� Z
l'a / o a m N \ / , � Y E y o ' e
V C U � K G A � \A V �\ - cc) ge 6 LT) re L 7 1 /9-9N m 1 ' � M \ � / oa/ c7 . t .
�t\ \,/,V” r Z e `
CO
CD 1 4� - < A V � � � \ � A \ . °� o u ;2.m0 � � V\
' t. ;
Iii Z v____; 00o
u ° ar � o
°
m
m 2<_ '
a c
PREPARED 3/16/10, 13:58:36 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 3/17/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (EFT) PHONE : (910) 433 -4337
OWNER . . BFT INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -4015 RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
B103 02 11/30/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 DP 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR -
B103 03 12/08/09 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001858877
12/08/09 DA T /S: 12/07/2009 01:23 PM RDCONTE
Projection still not met.
T /S: 12/08/2009 09:52 AM DETAYLOR
B103 04 12/17/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001862523
12/17/09 AP
B105 01 1/28/10 JH R *OPEN FLOOR VRU #: 001876390
1/28/10 AP
R427 01 2/25/10 DT FOUR TRADE ROUGH IN >2500 VRU #: 001886654
2/25/10 DA 1. Ladder frame all gables.
2. Exhaust ducts for bath fans can't exceed 14 ft flex.
3. Window within 24 inches of back door must be tempered.
4. Need engineer repair for floor truss bored for water
lines above family room.
5. Need nail guard for shower water lines in master.
6. Vent in b/r 3 needs mid -story guide.
T /S: 02/25/2010 09:31 AM DETAYLOR
R427 02 3/15/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001894450
3/15/10 AP
A814 01 3/16/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001894963
3/16/10 AP T /S: 03/15/2010 11:23 AM VBROWN
44 william bethune ct lot 18
CONTINUED ONTO NEXT PAGE
PREPARED 3/16/10, 13:58:36 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 3/17/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BET) PHONE : (910) 433 -4337
OWNER . . ': BFT'BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
linden 28356
T /S: 03/16/2010 10:18 AM TWARD
I129 01 3/17 'TfII /. R *INSULATION INSPECTION VRU #: 001895580
COMMENTS AND NOTES
PREPARED 4/27/10, 13:59:07 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 4/28/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BFT) PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18-401S RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' - NEW WATER SUPPLY UNKNOWN
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
3101 01 4/28/10
t r fl !0 d•QbF�rIL—. TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001916634
COMMENTS AND NOTES
PREPARED 5/21/10, 14:00:47 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 5/24/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BFT) PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18-401S RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE - SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
B103 02 11/30/09 DT - R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 DP 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR
B103 03 12/08/09 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001858877
12/08/09 DA T /S: 12/07/2009 01:23 PM RDCONTE
Projection still not met.
T /S: 12/08/2009 09:52 AM DETAYLOR
B103 04 12/17/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001862523
12/17/09 AP
B105 01 1/28/10 JH R *OPEN FLOOR VRU #: 001876390
1/28/10 AP
R427 01 2/25/10 DT FOUR TRADE ROUGH IN >2500 VRU #: 001886654
2/25/10 DA 1. Ladder frame all gables.
2. Exhaust ducts for bath fans can't exceed 14 ft flex.
3. Window within 24 inches of back door must be tempered.
4. Need engineer repair for floor truss bored for water
lines above family room.
5. Need nail guard for shower water lines in master.
6. Vent in b/r 3 needs mid -story guide.
T /S: 02/25/2010 09:31 AM DETAYLOR
R427 02 3/15/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001894450
3/15/10 AP
A814 01 3/16/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001894963
3/16/10 AP T/S: 03/15/2010 11:23 AM VBROWN
44 william bethune ct lot 18
linden 28356
CONTINUED ONTO NEXT PAGE
PREPARED 5/21/10, 14:00:47 INSPECTION TICKET PAGE 3
Harnett County INSPECTOR: IVR DATE 5/24/10
S
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (EFT) PHONE : (910) 433 -4337
OWNER . . : EFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
T /S: 03/16/2010 10:18 AM TWARD
I129 01 3/17/10 JH R *INSULATION INSPECTION VRU #: 001895580
3/17/10 AP
H824 01 4/27/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001917608
4/27/10 AP T /S: 04/28/2010 10:02 AM SSTEWART
T /S: 04/28/2010 10:02 AM SSTEWART
R429 01 5/24/10 TI FOUR TRADE FINAL VRU #: 001929413
cc; 1)
COMMENTS AND NOTES
PREPARED 5/24/10, 13:58:30 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 5/25/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BFT) PHONE : (910) 433 -4337
OWNER : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA OAKS #18 -4015 RT ON ELLIOTT
BRIDGE RD RT ON WILL LUCAS RD S/D ON RT
ON CAROLINA OAKS CIRCLE RT ON WILLIAM
BETHUNE CIRCLE LOT ON RT.JD
STRUCTURE: 000 000 44X50 3BR W /GARAGE (02)
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001840685
10/23/09 AP
B103 01 11/20/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001852995
11/20/09 DA Entire top of footer must be clean of debris, mortar, dirt
etc. so projection and bed joint can be properly inspected.
T /S: 11/20/2009 12:43 PM DETAYLOR
B103 02 11/30/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001855774
11/30/09 DP 1. Top of footer still not clear of mortar and debris.
Unable to verify piers are in center third of footers, and
projection in areas highlighted on plans. Clean of footers
and have engineer repairs where needed.
$50.00 re- inspection fee.
T /S: 11/30/2009
09:20 AM DETAYLOR
B103 03 12/08/09 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001858877
12/08/09 DA T /S: 12/07/2009 01:23 PM RDCONTE
Projection still not met.
T /S: 12/08/2009 09:52 AM DETAYLOR
B103 04 12/17/09 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001862523
12/17/09 AP
B105 01 1/28/10 JH R *OPEN FLOOR VRU #: 001876390
1/28/10 AP
R427 01 2/25/10 DT FOUR TRADE ROUGH IN >2500 VRU #: 001886654
2/25/10 DA 1. Ladder frame all gables.
2. Exhaust ducts for bath fans can't exceed 14 ft flex.
3. Window within.24 inches of back door must be tempered.
4. Need engineer repair for floor truss bored for water
lines above family room.
5. Need nail guard for shower water lines in master.
6. Vent in b/r 3 needs mid -story guide.
T /S: 02/25/2010 09:31 AM DETAYLOR
R427 02 3/15/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001894450
3/15/10 AP
A814 01 3/16/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001894963
3/16/10 AP T /S: 03/15/2010 11:23 AM VBROWN
V william bethune ct lot 18
linden 28356
CONTINUED ONTO NEXT PAGE
PREPARED 5/24/10, 13:58:30 INSPECTION TICKET PAGE 3
Harnett County INSPECTOR: IVR DATE 5/25/10
ADDRESS . : 44 WILLIAM BETHUNE CT SUBDIV: CAROLINA OAKS 64 LOTS
CONTRACTOR : WILLIAM JACKSON GC (BFT) PHONE : (910) 433 -4337
OWNER . . : BFT BUILDERS INC #18 PHONE : (910) 433 -4337
PARCEL . . : 01 -0544- - -0012- -18-
APPL NUMBER: 08- 50019596 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
T /S: 03/16/2010 10:18 AM TWARD
I129 01 3/17/10 JH R *INSULATION INSPECTION VRU #: 001895580
3/17/10 AP
H824 01 4/27/10 OT VENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001917608
4/27/10 AP T /S: 04/28/2010 10:02 AM SSTEWART
T /S: 04/28/2010 10:02 AM SSTEWART
R429 01 5/24/10 JH FOUR TRADE FINAL VRU #: 001929413
5/24/10 DP )Caulk all toilets.
)Missing all vent registers on first floor.
S)Need 2 ground rods @ meter.
t)Need grounding bar for phone & cable @ meter.
$7 drain in crawl needs to go to the outside of
the foundation wall.
',Sleeve & seal refrigerant lines all the way through
foundation wall inside & outside.
R429 02 5/25/10 TI FOUR TRADE FINAL VRU #: 001931815
.S ,25:/4 r
COMMENTS AND NOTES
.' .. m . 7 . 1 t ; Ni : P '',41t:7•1" 7 g . o 1 1 4 n - X• ''4 i 7i + r • y 1 •
tialaniAtZliiiiWa .
County of Harnett
Building Inspections Department
Planning Services p iii
. 1 Certificate of Compliance: Occupancy: k/
Certificate issued re ursuant to the requirements of North Carolina General Statute 153A -363 and Harnett
p q 'i'%
County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the
various ordinances of the County Harnett and the North Carolina State Building Codes. For the following:
Use Classification: Permit Numbers
Name: 6(T /' Ll /f ri72( Building: v
Electrical: Cr
:• Address: U4/ W, (f :, �zdib C 4 Insulation: t
7
Plumbing: '1
Mechanical: �1
FG Home:
Date: - / B Official: -� /1
p
a VA TV AII, 7 4\1 11r441 11 Z 1 ; ""r t 7I ‘ 1 ; . . . . ' 777,W.