Loading...
INSPECTIONS PREPARED 10/19/09, 13 :59:04 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 10/20/09 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01 APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO.LAKES ROAD (SR #1115), TURN LEFT.,GOTO /AMARILLO LANE, JUST BEFORE YOU GET -.TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE FLOOD ZONE X PROPOSED USE . . . . . : RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS C151 01 10/20/09 TI C *BLDG FOOTING VRU #: 001838578 /0 g COMMENTS AND NOTES P pilial C oo fe PREPARED 10/26/09, 14:00:13 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 10/27/09 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P357 01 10/27/09 TI C *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001842434 76 - 9 T /S: 10/26/2009 01:21 PM VBROWN CUSTOMER REQUEST PM INSPECTION. COMMENTS AND NOTES PREPARED 11/02/09, 13:59:35 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 11/03/09 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE RETAIL SEPTIC - EXISTING' SEWER PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS C151 01 10/20/09 MR C *BLDG FOOTING VRU #: 001838578 10/20/09 AP T /S: 10/20/2009 11:52 AM MREARIC parial.. footer pads C159 01 10/30/09 MR C *BLDG SLAB INSP VRU #: 001844311 10/30/09 CA T /S: 10/30/2009 10:52 AM MREARIC C159 02 11/03/09 TI C *BLDG SLAB INSP VRU #: 001845221 A E- M2 VOICE MESSAGE LEFT COMMENTS AND NOTES DE l told 4 Lefler Prow.* tk 0 U v C 1.4. c Sc Gcs} - Sf cu PREPARED 11/03/09, 14:00:06 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 11/04/09 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CTSP 00 CP TEMP ELECTRICAL SERVICE REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS E207 01 11/04/09 TI R *ELEC TEMP SERVICE POLE VRU #: 001845866 C OMMENTS AND NOTES PREPARED 11/04/09, 13:59:31 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 11/05/09 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CTSP 00 CP TEMP ELECTRICAL SERVICE REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS E207 01 11/04/09 R *ELEC TEMP SERVICE POLE VRU #: 001845866 11/04/09 DA T /S: 11/04/2009 11:44 AM MREARIC install panel face E207 02 11/05/09 TI R *ELEC TEMP SERVICE POLE VRU #: 001846690 -5 •q a I would like a a afternoon inspection if possible. - x �� COMMENTS AND NOTES X M PREPARED 12/14/09, 14:56:09 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 12/15/09 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS C151 01 10/20/09 MR C *BLDG FOOTING VRU #: 001838578 10/20/09 AP T /S: 10/20/2009 11:52 AM MREARIC parial.. footer pads C159 01 10/30/09 MR C *BLDG SLAB INSP VRU #: 001844311 10/30/09 CA T /S: 10/30/2009 10:52 AM MREARIC C159 02 11/03/09 MR C *BLDG SLAB INSP VRU #: 001845221 11/03/09 AE VOICE MESSAGE LEFT T /S: 11/03/2009 11:54 AM MREARIC pending leter from eng. oking sand under slab instead of rock C153 01 12/15/09 TI C *BLDG ROUGH IN VRU #: 001861756 (2, -t 5 -q AP-p.t( This is actually for the sheeting on the front. there was no place to schedule this, so i put it on the rough -in PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P357 01 10/27/09 FS C *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001842434 10/27/09 AP T /S: 10/26/2009 01:21 PM VBROWN CUSTOMER REQUEST PM INSPECTION. T /S: 10/27/2009 02:38 PM FSPIVEY P353 01 12/15/09 A TI � C *PLUMB WATER CONNECTION VRU #: 001861749 (2•ISPi P355 01 12/15/09 TI n c* PLUMB SEWER CONNECTION VRU #: 001861723 t 2.•r5 - 7 4P - t u t (. P355 02 12/15/09 TI C* PLUMB SEWER CONNECTION VRU #: 001861731 COMMENTS AND NOTES PREPARED 12/21/09, 14:44:24 INSPECTION TICKET PAGE Harnett County INSPECTOR: IVR DATE 12/22/09 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE - RETAIL SEPTIC - EXISTING' SEWER PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS C151 01 10/20/09 MR C *BLDG FOOTING VRU #: 001838578 10/20/09 AP T /S: 10/20/2009 11:52 AM MREARIC parial.. footer pads C159 01 10/30/09 MR C *BLDG SLAB INSP VRU #: 001844311 10/30/09 CA T /S: 10/30/2009 10:52 AM MREARIC C159 02 11/03/09 MR C *BLDG SLAB INSP VRU #: 001845221 11/03/09 AE VOICE MESSAGE LEFT T /S: 11/03/2009 11:54 AM MREARIC pending leter from eng. oking sand under slab instead of rock C153 01 12/15/09 MR C *BLDG ROUGH IN VRU #: 001861756 12/14/09 AP This is actually for the sheeting on the front. there was no place to schedule this, so i put it on the rough -in T /S: 12/15/2009 11:36 AM MREARIC C153 02 12/22/09 TI C *BLDG ROUGH IN VRU #: 001864414 {7 COMMENTS AND NOTES PREPARED 1/11/10, 14:00:38 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 1/12/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -D1- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CPIC 00 CP INSULATION COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 1185 01 1/12/10 TI /C *INSULATION INSPECTION VRU #: 001869384 -5: d ()A -1k4R PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P357 01 10/27/09 FS C *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001842434 10/27/09 AP T /S: 10/26/2009 01:21 PM VBROWN CUSTOMER REQUEST PM INSPECTION. T /S: 10/27/2009 02:38 PM FSPIVEY P353 01 12/15/09 MR C *PLUMB WATER CONNECTION VRU #: 001861749 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 02 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: "001861731 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 01 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861723 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P351 01 1/06/10 u: C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001868017 1/06/10 DA T /S: 01 /05/2010 03:42 PM NTART T /S: 01/06/2010 12:33 PM MREARIC water line must be checked with 100 lbs of pressure drain lin riser was not full P351 02 1/12/10 TI v C *PLUMBROUGH IN VRU #: 001869464 lzr COMMENTS AND NOTES 7 PREPARED 1/05/10, 15:42:58 INSPECTION TICKET PAGE 1 Harnett County: INSPECTOR: IVR DATE 1/06/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR: BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . : WE'LLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL : 03-S586-01- -0353- -01- APPL NUMBER: . 08-50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 0151 01 10/20/09 MR C *BLDG FOOTING VRU #: 001838578 10/20/09 AP T /S: 10/20/2009 11:52 AM MREARIC parial.. footer pads 0159 01 10/30/09 MR C *BLDG SLAB INSP VRU #: 001844311 10/30/09 CA T /S: 10/30/2009 10:52 AM MREARIC C159 02 11/03/09 MR C *BLDG SLAB INSP VRU #: 001845221 11/03/09 AE VOICE MESSAGE LEFT T /S: 11/03/2009 11:54 AM MREARIC pending leter from eng. oking sand under slab instead of rock 0153 01 12/15/09 MR C *BLDG ROUGH IN VRU #: 001861756 12/14/09 AP This is actually for the sheeting on the front. there was no place to schedule this, so i put it on the rough -in T /S: 12/15/2009 11:36 AM MREARIC 0153 02 12/22/09 MR C *BLDG ROUGH IN VRU #: 001864414 12/22/09 DA T /S: 12/22/2009 10:55 AM MREARIC 1. floor plans must reflect changes in lay out and be approved by plan review 2. provide a copy of UL 465 for inspection C153 03 1/06/10 TI C *BLDG ROUGH IN TIME: 17:00 - VRU #: 001867985 1 —6--,0 AA - T /S: 01/05/2010 03:41 PM NTART PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS E251 01 1/06/10 TI C *ELEC ROUGH IN TIME: 17:00 VRU #: 001867993 T /S: 01/05/2010 03:41 PM NTART PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED : INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS CONTINUED ONTO NEXT PAGE PREPARED 1/05/10, 15:42:58 INSPECTION TICKET PAGE 2 Harnett County, INSPECTOR: IVR DATE 1/06/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR ~: BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . : WE'LLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE REQUESTED INSP - DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS M459 01 1/06/10 TI C *MECH ROUGH IN TIME: 17:00 VRU #: 001868009 (o AP J'4Z vs: 01/05/2010 03:42 PM NTART PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P357 01 10/27/09 FS C *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001842434 10/27/09 AP T /S: 10/26/2009 01:21 PM VBROWN CUSTOMER REQUEST PM INSPECTION. T /S: 10/27/2009 02:38 PM FSPIVEY P353 01 12/15/09 MR C *PLUMB WATER CONNECTION VRU #: 001861749 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 02 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861731 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 01 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861723 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P351 01 1/06/10 TI C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001868017 -, / "c /O pA T /S: 01/05/2010 03:42 PM NTART COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DA'1"E: 01 -06 -10 PERMIT # 08- 50020846 ADDRESS: 1 amarillo lane VIOLATIONS: 1. The plumbing pipes must be tested to 100 # 2. No water in drain line riser 3. Electric service does not match plans or meet NEC code. This building does not appear to meet any of the exceptions of NEC 230 -2 230.70 General Means shall be provided to disconnect all conductors in a building or other structure from the service entrance conductors 230.71 Maximum Number of Disconnects. (A) General. The service disconnecting means for each service permitted by 230.2, or for each set of serviceentrance conductors permitted by 230.40, Exception No. 1, 3, 4, or 5, shall consist of not more than six switches or sets of circuit breakers, or a combination of not more than six switches and sets of circuit breakers, mounted in a single enclosure, in a group of separate enclosures, or in or on a switchboard. There shall be not more than six sets of disconnects per service grouped in any one location Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 1/12/10, 14:46:28 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 1/13/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CPIC 00 CP INSULATION' COMMERCIAL REQUESTED 'INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS I185 01. 1/12/10 MR C *INSULATION INSPECTION VRU #: 001869384 1/12/10 DA T /S: 01/12/2010 08:58 AM MREARIC lmb not complete I185 02 1/13/10 TI �� C *INSULATION INSPECTION TIME: 17:00 VRU #: 001870302 . T /S: 01/12/2010 02:46 PM NTART PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P357 01 10/27/09 FS C *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001842434 10/27/09 AP T /S: 10/26/2009 01:21 PM VBROWN CUSTOMER REQUEST PM INSPECTION. T /S: 10/27/2009 02:38 PM FSPIVEY P353 01 12/15/09 MR C *PLUMB WATER CONNECTION VRU #: 001861749 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 02 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861731 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 01 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861723 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P351 01 1/06/10 MR C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001868017 1/06/10 DA T /S: 01/05/2010 03:42 PM NTART T /S: 01/06/2010 12:33 PM MREARIC water line must be checked with 100 lbs of pressure drain lin riser was not full P351 02 1/12/10 MR ( C *PLUMB ROUGH IN VRU #: 001869464 1/12/10 DP T /S: 01/12/2010 08:59 AM MREARIC still no tests ready P351 03 1/13/10 TI C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001870294 ( - ) 3.10 PF4 T /S: 01/12/2010 02:45 PM NTART COMMENTS AND NOTES PREPARED 2/12/10, 13:58:10 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/15/10 ADDRESS 1 AMARILLO LN SIGN{ SUBDIV: CONTRACTOR BRADLEY BUILT PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING'r • SEWER PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS E251 01 1/06/10 MR C *ELEC ROUGH IN TIME: 17:00 VRU #: 001867993 1/06/10 DA T /S: 01/05/2010 03:41 PM NTART service does not match plans or meet the code the service cannot have more than 6 disconnects T /S: 01/06/2010 12:31 PM MREARIC E257 01 2/15/10 TI C *ELEC OVERHEAD TIME: 17:00 VRU #: 001883024 2 •J5-IO T /S: 02/12/2010 01:51 PM NTART ABOVE CEILING MON PM COMMENTS AND NOTES A 2 VUr l kcow.r��� F PREPARED .3/11/10, 14:01:41 INSPECTION TICKET PAGE 5 Harnett County - INSPECTOR: IVR DATE 3/12/10 ADDRESS . : 1 AMARILLO LN SIGN ,. SUBDIV: CONTRACTOR .tBRRDLEY "BUILTINC PHONE : .(919) 639 -2073 OWNER : WELLCO CONTRACTORS INC* ` PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING? • SEWER PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS E251 01 1/06/10 MR C *ELEC ROUGH IN TIME: 17:00 VRU #: 001867993 1/06/10 DA T /S: 01/05/2010 03:41 PM NTART service does not match plans or meet the code the service cannot have more than 6 disconnects T /S: 01/06/2010 12 :31 PM MREARIC E257 01 2/15/10 MR C *ELEC OVERHEAD TIME: 17:00 VRU #: 001883024 2/15/10 AE T /S: 02/12/2010 01:51 PM NTART ABOVE CEILING MON PM T /S: 02/15/2010 12:52 PM MREARIC 2 middle units are not complete E253 01 3/12/10 TI C *ELEC TEMP POWER CERT TIME: 17:00 VRU #: 001894211 5"12 T /S: 03/11/2010 01:46 PM NTART PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS M459 01 1/06/10 MR C *MECH ROUGH IN TIME: 17:00 VRU #: 001868009 1/06/10 AP T /S: 01/05/2010 03:42 PM NTART T /S: 01/06/2010 12:33 PM MREARIC M463 01 3/12/10 TI n C *MECH OVERHEAD TIME: 17:00 VRU #: 001894229 3'( T /S: 03/11/2010 01:46 PM NTART PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P357 01 10/27/09 FS C *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001842434 10/27/09 AP T /S: 10/26/2009 01:21 PM VBROWN CUSTOMER REQUEST PM INSPECTION. T /S: 10/27/2009 02:38. PM FSPIVEY P353 01 12/15/09 MR C *PLUMB. WATER CONNECTION VRU #: 001861749 0 Vex? CONTINUED ONTO NEXT PAGE PREPARED 3/11/10, 14:01:41 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 3/12/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR BR4DLEY BUILT INC - PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 02 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861731 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 01 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861723 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P351 01 1/06/10 MR C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001868017 1/06/10 DA T /S: 01/05/2010 03:42 PM NTART T /S: 01/06/2010 12:33 PM MREARIC water line must be checked with 100 lbs of pressure drain lin riser was not full P351 02 1/12/10 MR C *PLUMB ROUGH IN VRU #: 001869464 1/12/10 DP T /S: 01/12/2010 08:59 AM MREARIC still no tests ready P351 03 1/13/10 MR C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001870294 1/13/10 AP T /S: 01/12/2010 02:45 PM NTART T /S: 01/13/2010 11:32 AM MREARIC P359 01 3/12/10 TI n C *PLUMB OVERHEAD TIME: 17:00 VRU #: 001894252 33 -12-1 T /S: 03/11/2010 01:48 PM NTART COMMENTS AND NOTES &• y_ 1 ♦ 1 .fl'MS+r. • r r- u••‘:. � t i c q rf <: f}i�p• ian l • EXPIRE DATE 6 2 1© T 45 3 4 TEMPORARY POWER CERTIFICATE JOB NAME ea gin t ma_ • OWNER end Pn ADDRESS PHONE LOCATION /— I4.a�i ��o 1 The power company shall not be required to terminate electric service supplied, to the premises described above on or after the expiration date specified in this certificate; unless and until it is notified in by the Harnett County Electrical Inspector to do so. I the undersigned understand that this certificate is for Temporary Power only and that a final inspection is required before permanent power will be approved. I shall also comply with any special requirement requested by the Harnett County Inspection Department. Date - / 2 - ( 0 c2 Owner or Authorized Signature This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code certifying at the time of issuance this structure was in temporary compliance with the various'aidinances of the County of Harnett regulating building construction or use. c�- / � Date 3 ' /Z ' IC (' 1���*�" f Building Official (! Vr -,e -• e .wu...v.w= ..- .�..w^. °..•..ry -•.;+r•w.+..ry +...x. -:.v -� N F . r .._.,., . ..,........- .,.. __ w...r -,w. [..+:as?;. -C.'' t ... ... e.� +� .r., ..:sae. rr,w . • • DO NOT REMOVE! • Harnett County Inspection Department 102 East Front Street • P.O. Box 65 • Lillington, NC 27546 Phone: (910)893 -7 • Fax: (910) 893 -2793 Job Name: /`P,d h �c !1tJ I I� Date: ' ( Z- • Address: 1 — A rn. c r Lot No.: Permit No.• • (Check Box for Violation) a o a o Q Footing Foundation Bldg. Elec. Plumb. Mech. Insul. Floor Fram. Floor MFG. Modular Damp /Water Structural Wall Other Slab Home Proof. Sheath. Violations Found: 1 � Cl 11 -. Fex Gh'ol.t Cer /Jrr / Per ('c-.ce I 1 5 to 1,! (� 0 in -7reo r• / t, ( a c_i' 'F r c^I u. I/ N f GA 3) LI fl le_on5 ,A1IrgU9 nue CfecA • Code Enforcement Official Date: Signature X,/ . r ti_ • It is unlawful for any sub contractor, general contractor, or owner to cover or cause to be covered any part of the work with flooring, sheetrock, earth or other material until the proper inspector had ample time to approve the installation. WHITE COPY - CONTRACTOR /OWNER • YELLOW COPY - INSPECTORS PREPARED 4/01/10, 14:01:15 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 4/05/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING' • SEWER PERMIT: CPLU 00 CP LAND USE PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS Z820 01 4/05/10 TI PZ *ZONING /FINAL INSPECTION TIME: 17:00 VRU #: 001904002 9/QS //n hoe T /S: 04/01/2010 12:35 PM DJOHNSON COMMENTS AND NOTES &lir 1011° PREPARED 4/12/10, 13:59:00 INSPECTION TICKET PAGE 2 Harnett County .; INSPECTOR: IVR DATE 4/13/10 r ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE DIRECTIONS : DIRECTIONS HERE BUFFALO LKES BUSINESS PARK #7 TAKE NC 27 WEST TO BUFFALLO LAKES ROAD (SR #1115), TURN LEFT. GOTO AMARILLO LANE, JUST BEFORE YOU GET TO SPOUT SPRINGS EMERGENCY SERVICES BUILDING. TURN RIGHT ONTO AMARILLO LANE, SITE IS ON RIGHT. T /S: 09/15/2008 03:33 PM RDCONTE - -- STRUCTURE: 000 000 8,400 SQ. FT. RETAIL SPACE FLOOD ZONE • FLOOD ZONE X PROPOSED USE • RETAIL SEPTIC - EXISTING? • SEWER PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS C151 01 10/20/09 MR C *BLDG FOOTING VRU #: 001838578 10/20/09 AP T /S: 10/20/2009 11:52 AM MREARIC parial.. footer pads C159 01 10/30/09 MR C *BLDG SLAB INSP VRU #: 001844311 10/30/09 CA T /S: 10/30/2009 10:52 AM MREARIC C159 02 11/03/09 MR C *BLDG SLAB INSP VRU #: 001845221 11/03/09 AE VOICE MESSAGE LEFT T /S: 11/03/2009 11:54 AM MREARIC pending leter from eng. oking sand under slab instead of rock C153 01 12/15/09 MR C *BLDG ROUGH IN VRU #: 001861756 12/14/09 AP This is actually for the sheeting on the front. there was no place to schedule this, so i put it on the rough -in T /S: 12/15/2009 11:36 AM MREARIC C153 02 12/22/09 MR C *BLDG ROUGH IN VRU #: 001864414 12/22/09 DA T /S: 12/22/2009 10:55 AM MREARIC 1. floor plans must reflect changes in lay out and be approved by plan review 2. provide a copy of UL 465 for inspection C153 03 1/06/10 MR C *BLDG ROUGH IN TIME: 17:00 VRU #: 001867985 1/06/10 DA T /S: 01/05/2010 03:41 PM NTART T /S: 01/06/2010 12:30 PM MREARIC subs not complete F854 02 4/08/10 DJ FM *FINAL INSPECTION VRU #: 001906684 4/07/10 CA T /S: 04/07/2010 02:46 PM DJOHNSON F854 01 4/08/10 TM FM *FINAL INSPECTION VRU #: 001906676 4/02/10 AP T /S: 04/07/2010 05:25 PM TMCLAMB We finaled the shell building on 04/02/10 waiting for upfit plans T /S: 04/12/2010 09:26 AM NTART A814 01 4/09/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001907005 4/09/10 AP T /S: 04/08/2010 09:13 AM JBROCK 68 amarillo In lot 7 unit G CONTINUED ONTO NEXT PAGE PREPARED 4/12/10,.13:59:00 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 4/13/10 ADDRESS : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 74 amarillo ln lot 7 unit F 80 amarillo In lot 7 unit E 86 amarillo ln lot 7 unit D 92 amarillo ln lot 7 unit C 98 amarillo ln lot 7 unit B 104 amarillo ln lot 7 unit A Sanford 27332 T /S: 04/09/2010 04:56 PM TWARD C179 01 11'� 4/13/1 TI C *BLDG FINAL TIME: 17:00 VRU #: 001908482 4 /9 - ( }aftf T /S: 04/12/2010 09:24 AM NTART PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS E251 01 1/06/10 MR C *ELEC ROUGH IN TIME: 17:00 VRU #: 001867993 1/06/10 DA T /S: 01/05/2010 03:41 PM NTART service does not match plans or meet the code the service cannot have more than 6 disconnects T /S: 01/06/2010 12:31 PM MREARIC E257 01 2/15/10 MR C *ELEC OVERHEAD TIME: 17:00 VRU #: 001883024 2/15/10 AE T /S: 02/12/2010 01:51 PM NTART ABOVE CEILING MON PM T /S: 02/15/2010 12:52 PM MREARIC 2 middle units are not complete E253 01 3/12/10 MR C *ELEC TEMP POWER CERT TIME: 17:00 VRU #: 001894211 3/12/10 AP T /S: 03/11/2010 01:46 PM NTART T /S: 03/12/2010 01:34 PM MREARIC 3 month E265 01 3/19/10 TI C *ELEC FINAL VRU #: 001897255 3/18/10 CA i would like a pm inspection if possible T /S: 03/18/2010 02:28 PM NTART CANCELLED ELECTRICAL FINAL...ALL FINALS ARE DONE AT THE SAME TIME.FIRE MARSHALL MUST GO FIRST. NTART E265 03 4/08/10 DJ C *ELEC FINAL VRU #: 001906726 4/07/10 CA T /S: 04/07/2010 02:47 PM DJOHNSON fm inspection first then building E265 02 4/08/10 DJ C *ELEC FINAL VRU #: 001906692 4/07/10 CA T /S: 04/07/2010 02:46 PM DJOHNSON need fm inspection first E265 04 / 4 1 /13/10 TI C *ELEC FINAL TIME: 17:00 VRU #: 001908458 - /?-/O T /S: 04/12/2010 09 :22 AM NTART PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS CONTINUED ONTO NEXT PAGE PREPARED 4/12/10, 13:59:00 INSPECTION TICKET PAGE 4 Harnett County , INSPECTOR: IVR DATE 4/13/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . : 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS M459 01 1/06/10 MR C *MECH ROUGH IN TIME: 17 :00 VRU #: 001868009 1/06/10 AP T /S: 01/05/2010 03:42 PM NTART T /S: 01/06/2010 12:33 PM MREARIC M463 01 3/12/10 MR C *MECH OVERHEAD TIME: 17:00 VRU #: 001894229 3/12/10 AE T /S: 03/11/2010 01:48 PM NTART T /S: 03/12/2010 01:36 PM MREARIC reroute fresh air vent in unit G or install fire damper atwall penetration M465 02 4/08/10 DJ C *MECH FINAL VRU #: 001906742 4/07/10 CA T /S: 04/07/2010 02:48 PM DJOHNSON £m inspection first M465 01 4/08/10 DJ C *MECH FINAL VRU #: 001906734 4/07/10 CA T /S: 04/07/2010 02:47 PM DJOHNSON fm inspection first M465 03 4/13/10 TI C *MECH FINAL TIME: 17:00 VRU #: 001908466 4 T /S: 04/12/2010 09:23 AM NTART PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P357 01 10/27/09 FS C *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001842434 10/27/09 AP T /S: 10/26/2009 01:21 PM VBROWN CUSTOMER REQUEST PM INSPECTION. T /S: 10/27/2009 02:38 PM FSPIVEY P353 01 12/15/09 MR C *PLUMB WATER CONNECTION VRU #: 001861749 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 02 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861731 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P355 01 12/15/09 MR C *PLUMB SEWER CONNECTION VRU #: 001861723 12/14/09 AP T /S: 12/15/2009 11:37 AM MREARIC P351 01 1/06/10 MR C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001868017 1/06/10 DA T /S: 01/05/2010 03:42 PM NTART T /S: 01/06/2010 12:33 PM MREARIC water line must be checked with 100 lbs of pressure drain lin riser was not full P351 02 1/12/10 MR C *PLUMB ROUGH IN VRU #: 001869464 1/12/10 DP T /S: 01/12/2010 08:59 AM MREARIC still no tests ready P351 03 1/13/10 MR C *PLUMB ROUGH IN TIME: 17:00 VRU #: 001870294 1/13/10 AP T /S: 01/12/2010 02:45 PM NTART T /S: 01/13/2010 11:32 AM MREARIC P359 01 3/12/10 MR C *PLUMB OVERHEAD TIME: 17:00 VRU #: 001894252 3/12/10 AP T /S: 03/11/2010 01:48 PM NTART T /S: 03/12/2010 01:37 PM MREARIC P361 01 4/08/10 DJ C *PLUMB FINAL VRU #: 001906759 4/07/10 CA T /S: 04/07/2010 02:48 PM DJOHNSON CONTINUED ONTO NEXT PAGE ED 4/12/10, 13:59:00 INSPECTION TICKET PAGE 5 rnett County , - INSPECTOR: IVR DATE 4/13/10 ADDRESS . : 1 AMARILLO LN SIGN SUBDIV: CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : WELLCO CONTRACTORS INC PHONE : (910) 436 -3131 PARCEL . . 03- 9586 -01- -0353- -01- APPL NUMBER: 08- 50020846 CP NEW COMMERCIAL BLDG /ENTERPRISE REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS fm inspection first P361 02 4/13/10 TI C *PLUMB FINAL TIME: 17:00 VRU #: 001908474 q - 13 /a n "TA_ T /S: 04/12/2010 09:23 AM NTART COMMENTS AND NOTES c:f: S 6: t s :. E v C i< T N t r-.4 a: .r + d a t ewe:. y .- ' I ? ‘ 114. 4 :436 4 : CF■ccIP4A1P4- AAVAIV-14011k444 i County of Harnett Building' Inspections Department ib '> Planning Services Certificate of Compliance: x ,;Occupancy: s 'C ertificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett el County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the "•.'� various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: S — 5 tie(f 0h5 Permit Numbers Name: g ac e 'Apr prt scs / Li.0 Building: 0Fl- can ^7 n$-' 4 Electrical: t 1 ,., Address: / - As.nrt I/n Lase Insulation: tS Plumbing: . 1 6 7 Mechanical: 1 MFG Home:, Date: Li- ( . l Building Official: —7- - ,j jy cal R „ ile ‘, I T) I t iL V) I 7771 ,