Loading...
INSPECTIONS PREPARED 12/18/08, 14:05:11 INSPECTION TICKET PAGE 43 Harnett County INSPECTOR: IVR DATE 12/19/08 ADDRESS . : 78877 *UNASSIGNED SUBDIV: CAROLINA LAKES CONTRACTOR PHILS HOME IMPROVEMENT, INC. PHONE : (910) 980-1032 OWNER SMYTHE KENNETH E & CHARLENE C PHONE : PARCEL 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD, T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR E. DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 12/19/08 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 COMMENTS AND NOTES No r(&', s PREPARED 1/16/09, 14:03:09 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 1/20/09 ADDRESS . : 78877 *UNASSIGNED SUBDIV: CAROLINA LAKES CONTRACTOR : PHILS HOME IMPROVEMENT, INC. PHONE : (910) 980-1032 OWNER : SMYTHE KENNETH E & CHARLENE C PHONE : PARCEL : 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD, T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - B101 01 12/19/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 12/19/08 DP no plans on site B101 02 12/23/08 FS R*BLDG FOOTING / TEMP SVC POLE VRU 001720440 12/23/08 AP B103 01 1~/, 120//09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001726957 COMMENTS AND NOTES PREPARED 3/18/09, 14:58:20 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 3/19/09 - i ADDRESS 78877 *UNASSIGNED SUBDIV: CAROLINA LAKES CONTRACTOR PHILS HOME IMPROVEMENT, INC. PHONE (910) 980-1032 OWNER SMYTHE KENNETH E & CHARLENE C PHONE PARCEL 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) - - DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD, T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR-& DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - B101 01 12/19/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 12/19/08 DP no plans on site B101 02 12/23/08 FS R*BLDG FOOTING / TEMP SVC POLE VRU 001720440 12/23/08 AP B103 01 1/20/09 MR nn R*BLDG FOUND & TEMP SVC POLE VRU 001726957 1/21/09 AE / damp proofing req.d at open floor B105 01 1/23/09 TI R*OPEN FLOOR VRU 001728054 2 6 IV-big A814 01 3/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001745199 R427 01 3/19/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001745207 COMMENTS AND NOTES - HARNETT COUNTY Building Inspections Dept. 108 E. Front St. L.illington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 3-19-09 PERMIT# 08-50021340 ADDRESS: harborview - Carolina lakes VIOLATIONS: 1. Strap dormers to trusses and support under side walls 2. Strap truss D2 to specs at all points 3. Raise washer box 4. Plumb. Not ready 5. Mid level bracing 6. Strap pex under house @ 32" 7. Fireblock soffit in kitchen 8. Outlet needed right of door in nook 9. Outlet needed left of door in MBR 10. Nail all truss hangers 11. Add truss straps on trusses over front bonus rm. 12. Attic access must be 30 x22 min. 13.Ok to side 14. Baffles over bonus rm are too short to reach above the ins. Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 3/23/09, 13:59:18 INSPECTION TICKET PAGE 11 Harnett Founty INSPECTOR: IVR DATE 3/24/09 ADDRESS . : 119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONTRACTOR : PHILS HOME IMPROVEMENT, INC. PHONE : (910) 980-1032 OWNER : SMYTHE KENNETH E & CHARLENE C PHONE : PARCEL : 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD, T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 12/19/08 MR - R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 12/19/08 DP no plans on site B101 02 12/23/08 FS R*BLDG FOOTING / TEMP SVC POLE VRU 001720440 12/23/08 AP B103 01 1/20/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001726957 1/21/09 AE' damp proofing reg.d at open floor B105 01 1/23/09 TI R*OPEN FLOOR VRU 001728054 I,2(-4 AP-Mg, A814 01 3/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001745199 3/20/09 AP 119 harborview dr lot 7 G R427 01 3/19/09 FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001745207 3/19/09 DA "2' Strap dormers to trusses and support under side walls 2. Strap truss D2 to specs at all points -k ro Raise washer box .4. Plumb. Not ready ,F. Mid level bracing `6c Strap pex under house ® 32" Vc - Fireblock soffit in kitchen Itroutiet needed right of door in nook 'M Outlet needed left of door in MBR F Nail all truss hangers r1I..Add truss straps on trusses over front bonus rm. -=X- Attic access must be 30 x22 min. --TEW~ Ok to side R427 02 3/24/09 TI FOUR TRADE ROUGH IN >2500 VRU 001746506 '~-2 9 ~Y - M 2 - - COMMENTS AND NOTES - ~~GX HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 3-24-09 PERMIT# 08-50021340 ADDRESS: 119 harborview VIOLATIONS: 1. Provide a gauge on water pressure test 2. When are you going to install the tub and how will it be plumbed and vented? 3. Firecaulk the new fireblocking in the kitchen soffit area 4. Please note P802.4 of the plumbing code calls for the opening of the washer standpipe to be 34" above the finished floor 5. Fireplace and tub and gas line to fireplace(with press. Test) must be in to pass rough inspection 6. Ok to insulate.. I can check these items at insulation insp. Fie S'o - Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 4/14/09, 13:59:10 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 4/15/09 ---=-j - - - ADDRESS : 119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONTRACTOR : PHILS HOME IMPROVEMENT, INC. PHONE : (910) 980-1032 OWNER : SMYTHE KENNETH E & CHARLENE C PHONE : PARCEL : 03-9585-07- -0007- - - APPLNUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD,.T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - -101 01 12/19/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 12/19/08 DP no plans on site B101 02 12/23/08 FS R*BLDG FOOTING / TEMP SVC POLE VRU 001720440 12/23/08 AP B103 01 1/20/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001726957 1/21/09 AE damp proofing req.d at open floor B105 01 1/23/09 MR R*OPEN FLOOR VRU 001728054 3/24/09 AP A814 01 3/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001745199 3/20/09 AP 119 harborview dr lot 7 G R427 01 3/19/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001745207 3/19/09 DA 1. Strap dormers to trusses and support under side walls 2. Strap truss D2 to specs at all points 3. Raise washer box 4. Plumb. Not ready 5. Mid level bracing 6. Strap pex under house ® 32" 7. Fireblock soffit in kitchen 8. Outlet needed right of door in nook 9. Outlet needed left of door in MBR 10. Nail all truss hangers 11. Add truss straps on trusses over front bonus rm. 12. Attic access must be 30 x22 min. 13. Ok to side R427 02 3/24/09 up_ FOUR TRADE ROUGH IN >2500 VRU 001746506 3/24/09 DP, gauge needed for plmb test 2 wher is tub or plmb.? firecaulk the fireblocking at kitch soffit ,-W-washer box must be 34" at final 5. fireplace and tub and gas line must be installed for rough insp. 6. ok to insulate fee 50.00 R427 03 4/15/09 TI FOUR TRADE ROUGH IN >2500 VRU 001755073 I6 -9 DA J COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 4-15-09 PERMIT# 08-50021340 ADDRESS: 119 harborview VIOLATIONS: 1. Insulation insufficient at living room ceiling perimeter 2. Access needed to area over master bedroom 3. When ready call in for a rough and an insulation inspection before continuing Hamett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 4/15/09, 14:00:57 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 4/16/09 ADDRESS :-119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONTRACIIOR :.1'4"HILS HOME IMPROVEMENT, INC. PHONE (910) 980-1032 OWNER : SMYTHE KENNETH E & CHARLENE C PHONE PARCEL : 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD, T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON.HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 12/19/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 12/19/08 DP no plans on site B101 02 12/23/08 FS R*BLDG FOOTING / TEMP SVC POLE VRU 001720440 12/23/08 AP B103 01 1/20/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001726957 1/21/09 AE damp proofing req.d at open floor B105 01 1/23/09 MR R*OPEN FLOOR VRU 001728054 3/24/09 AP A814 01 3/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001745199 3/20/09 AP 119 harborview dr lot 7 G R427 01 3/19/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001745207 3/19/09 DA 1. Strap dormers to trusses and support under side walls 2. Strap truss D2 to specs at all points 3. Raise washer box 4. Plumb. Not ready 5. Mid level bracing 6. Strap pex under house ® 32" 7. Fireblock soffit in kitchen 8. Outlet needed right of door in nook 9. Outlet needed left of door in MBR 10. Nail all truss hangers 11. Add truss straps on trusses over front bonus rm. 12. Attic access must be 30 x22 min. 13. Ok to side R427 02 3/24/09 MR FOUR TRADE ROUGH IN >2500 VRU 001746506 3/24/09 DP 1. gauge needed for plmb test 2. wher is tub or plmb.? 3. firecaulk the fireblocking at kitch soffit 4.washer box must be 34" at final 5. fireplace and tub and gas line must be installed for rough insp. 6. ok to insulate fee 50.00 R427 03 4/15/09 FOUR TRADE ROUGH IN >2500 VRU 001755073 4/15/09 DA 1. insulation insufficient at living room ceiling perimeter 2. access needed over mbr - CONTINUED ONTO NEXT PAGE - - PREPARED 4/15/09, 14:00:57 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 4/16/09 - - - ADDRESS . : 119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONTRACTOR :.C~HILS HOME IMPROVEMENT, INC. PHONE : (910) 980-1032 OWNER SMYTHE KENNETH E & CHARLENE C PHONE : PARCEL 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3. call for rough and insul. insp. 1129 01 4/16/09 TI R*INSULATION INSPECTION VRU 001755997 44-/GA AP-~-g R427 04 4/16/09 d~TpII ~~~~p~ FOUR TRADE ROUGH IN >2500 VRU 001756004 4- /6, -j - - COMMENTS AND NOTES PREPARED 8/18/09, 14:00:30 INSPECTION TICKET PAGE 5 Harnett County:, INSPECTOR: IVR DATE 8/19/09 ADDRESS 119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONTRACTC,R,: Ik3LS HOME IMPROVEMENT, INC. PHONE (910) 980-1032 OWNER SMYTHE KENNETH E & CHARLENE C PHONE PARCEL 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD, T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 12/19/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 12/19/08 DP no plans on site B101 02 12/23/08 FS R*BLDG FOOTING / TEMP SVC POLE VRU 001720440 12/23/08 AP B103 01 1/20/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001726957 1/21/09 AE damp proofing req.d at open floor B105 01 1/23/09 MR R*OPEN FLOOR VRU 001728054 3/24/09 AP A814 01 3/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001745199 3/20/09 AP x/119 harborview dr lot 7 G R427 01 3/19/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001745207 3/19/09 DA 1. Strap dormers to trusses and support under side walls 2. Strap truss D2 to specs at all points 3. Raise washer box 4. Plumb. Not ready 5. Mid level bracing 6. Strap pex under house @ 32" 7. Fireblock soffit in kitchen 8. Outlet needed right of door in nook 9. Outlet needed left of door in MBR 10. Nail all truss hangers 11. Add truss straps on trusses over front bonus rm. 12. Attic access must be 30 x22 min. 13. Ok to side R427 02 3/24/09 MR FOUR TRADE ROUGH IN >2500 VRU 001746506 3/24/09 DP 1. gauge needed for plmb test 2. wher is tub or plmb.? 3. £irecaulk the fireblocking at kitch soffit 4.washer box must be 34" at final 5. fireplace and tub and gas line must be installed for rough insp. 6. ok to insulate fee 50.00 R427 03 4/15/09 MR FOUR TRADE ROUGH IN >2500 VRU 001755073 4/15/09 DA 1. insulation insufficient at living room ceiling perimeter 2. access needed over mbr CONTINUED ONTO NEXT PAGE - PREPARED 8/18/09, 14:00:30 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 8/19/09 7 ADDRESS . : 119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONTRACTOR : I~ ILS HOME IMPROVEMENT, INC. PHONE (910) 980-1032 OWNER SMYTHE KENNETH E & CHARLENE C PHONE PARCEL 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3. call for rough and insul. insp. 1129 01 4/16/09 MR R*INSULATION INSPECTION VRU 001755997 4/16/09 AP R427 04 4/16/09 MR FOUR TRADE ROUGH IN >2500 VRU 001756004 4/16/09 AP R431 01 8/19//09 T FOUR TRADE FINAL >2500 VRU 001810767 - 9( G9 COMMENTS AND NOTES n 1 HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 08-19-09 PERMIT # 08-50021340 ADDRESS: 119 harborview VIOLATIONS: 1. Insulate water lines under arage sink and insul the p-trap 2. Attach the jaccuzzi recept. Under tub to something 3. Bond the faucet at tub to motor 4. Caulk around toilets 5. Provide continuous access to AHU in attic 6. Caulk all outside penetrations 7. Provide kick plates on rear steps (max. 4" opening) 8. Finish the front porch walk area 9. Fee 50.00 ahu Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 8/19/09, 14:00:38 INSPECTION TICKET PAGE 10 Harnett.County INSPECTOR: IVR DATE 8/20/09 - - - - - ADDRESS . : 119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONpRACTO, PHILS HOME IMPROVEMENT, INC. PHONE (910) 980-1032 OWNER SMYTHE KENNETH E & CHARLENE C PHONE PARCEL 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TAKE HWY 27 TO BUFFALO LAKES ROAD, T/L INTO CAROLINA LAKES, T/L ON CAROLINA WAY, T/R ON WOOD RUN, T/R ON HARBOR VIEW. SITE IS ON LEFT. T/S: 12/03/2008 12:29 PM RDCONTE STRUCTURE: 000 000 72X57 CRAWL 4BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - B101 01 12/19/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001719046 12/19/08 DP no plans on site B101 02 12/23/08 FS R*BLDG FOOTING / TEMP SVC POLE VRU 001720440 12/23/08 AP B103 01 1/20/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001726957 1/21/09 AE damp proofing req.d at open floor B105 01 1/23/09 MR R*OPEN FLOOR VRU 001728054 3/24/09 AP A814 01 3/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001745199 3/20/09 AP ✓119 harborview dr lot 7 G R427 01 3/19/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001745207 3/19/09 DA 1. Strap dormers to trusses and support under side walls 2. Strap truss D2 to specs at all points 3. Raise washer box 4. Plumb. Not ready 5. Mid level bracing 6. Strap pex under house @ 32" 7. Fireblock soffit in kitchen 8. Outlet needed right of door in nook 9. Outlet needed left of door in MBR 10. Nail all truss hangers 11. Add truss straps on trusses over front bonus rm. 12. Attic access must be 30 x22 min. 13. Ok to side R427 02 3/24/09 MR FOUR TRADE ROUGH IN >2500 VRU 001746506 3/24/09 DP 1. gauge needed for plmb test 2. when is tub or plmb.? 3. firecaulk the £ireblocking at kitch soffit 4.washer box must be 34" at final 5. fireplace and tub and gas line must be installed for rough insp. 6. ok to insulate fee 50.00 R427 03 4/15/09 MR FOUR TRADE ROUGH IN >2500 VRU 001755073 4/15/09 DA 1. insulation insufficient at living room ceiling perimeter 2. access needed over mbr CONTINUED ONTO NEXT PAGE PREPARED 8/19/09, 14:00:38 INSPECTION TICKET PAGE 11 Harnett Copnty INSPECTOR: IVR DATE 8/20/09 ADDRESS . : 119 HARBORVIEW DR SUBDIV: CAROLINA LAKES CONTRACY.)R PHILS HOME IMPROVEMENT, INC. PHONE (910) 980-1032 OWNER SMYTHE KENNETH E & CHARLENE C PHONE PARCEL 03-9585-07- -0007- - - APPL NUMBER: 08-50021340 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3. call for rough and insul. insp. 1129 01 4/16/09 MR R*INSULATION INSPECTION VRU 001755997 4/16/09 AP R427 04 4/16/09 MR FOUR TRADE ROUGH IN >2500 VRU 001756004 4/16/09 AP R431 01 8/19/09 FOUR TRADE FINAL >2500 VRU 001810767 8/19/09 DP T/S: 08/19/2009 10:36 AM MREARIC insulate garage plmb 2 attach recept under tub 3a bond tub faucet to motor caulk toilets J5. provide continuous access to attic AHU /6l caulk all outside penetrations 7. provide toe plates on back stairs -A finish front porch walk area R431 02 8/20/09 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001811330 :Z0,2 A-P-,-mQ,_-T/S: 08/19/2009 01:41 PM RDCONTE - COMMENTS AND NOTES - - - e Qiv Ilk" "0 r:. COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION k AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105,oftheNorth Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in ' compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: t ? I~~ Use Classification: FR--3 Conditional Use Permit No.: l e Type of Construction: -tf-- Building Permit No:n Q g • SO B 21 3 y D Owner of Building: s Electrical Permit No.: t' f4,: Building Address: 19 r~ ,n t. r,o,.v Insulation Permit No.: r I Zoning District: Plumbing Permit No.: ,•Zoning'Pe'rmit No.: Mech. Permit No.: / D te: S 0 Envir. C.O. No.: Building Official Zoning Official