Loading...
INSPECTIONS PREPARED 1/29/09, 13:59:08 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 1/30/09 ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR MCLAMB NICHOLAS W PHONE (919) 552-1588 OWNER WAVERLY DEVELOPMENT CORP #17 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE .Z, STRUCTURE: 000 000 90K55 CRAWL 4BSD W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . NEW WATER SUPPLY . . . . . . . :'COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 1/30/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 4eff TSP IS READY.********************** COMMENTS AND NOTES r PREPARED 2/18/09, 13:59:48 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 2/19/09 ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR MCLAMB NICHOLAS W PHONE : (919) 552-1588 OWNER WAVERLY DEVELOPMENT CORP #17 PHONE : PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BBD W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT . RESULTS/COMMENTS B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok.... no premise number A814 01 2/19/09 TI ADDRESS CONFIRMATION VRU 001735968 B103 01 2/19/09 R*BLDG FOUND & TEMP SVC POLE VRU 001735950 . 2- 15 COMMENTS AND NOTES - PREPARED 2/26/09, 14:00:26 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR DATE 2/27/09 ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR MCLAMB NICHOLAS W PHONE (919) 552-1588 OWNER WAVERLY DEVELOPMENT CORP #17. PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok.... no premise number B103 01 2/19/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP A814 01 2/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP 104 Sherman pines dr lot 17 B105 01 21/,27/09 TI R*OPEN FLOOR VRU 001739002 COMMENTS AND NOTES PREPARED 4/22/09, 14:00:13 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 4/23/09 ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR : TRADEMARK BUILDERS, INC PHONE (919) 552-1588 OWNER : WAVERLY DEVELOPMENT CORP #17 PHONE PARCEL : 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -101 01 1/30/09 BS R -BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok....no premise number B103 01 2/19/09 KS- R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP A814 01 2/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP 104 sherman pines dr lot 17 B105 01 2/27/09 BS R*OPEN FLOOR VRU 001739002 2/27/09 AE 1. Flash ends of drop girders. 2. extra joist missing at corner of front porch. Install (circled on plan) will check at rough in. P307 01 4/23/0,1A TI . R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001758945 4 -a3'~ r4 PEP COMMENTS AND NOTES PREPARED 4/24/09, 13:59:28 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 4/27/09 ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR TRADEMARK BUILDERS, INC PHONE (919) 552-1586 OWNER WAVERLY DEVELOPMENT CORP #17 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 06-50020621 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 9OX55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok.... no premise number 8103 01 2/19/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP A814 01 2/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP 104 sherman pines dr lot 17 B105 01 2/27/09 BS R*OPEN FLOOR VRU 001739002 2/27/09 AE 1. Flash ends of drop girders. 2. extra joist missing at corner of front porch. Install (circled on plan) will check at rough in. P307 01 4/23/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001758945 4/23/09 AP R427 01 4/27/09 TI FOUR TRADE ROUGH IN >2500 VRU 001760230 7.09 COMMENTS AND NOTES 03/24/2009 13:38 9198739029 SOUTHERN ENGINEERS PAGE 01104 SOUTHERN ENGINEERS James Herman, PE - Owner Consulting Structural Engineers 8St3 -8~ ? ~ TO: TRADEMARK BUILDERS, INC. P.O. BOX 142 WILLOW SPRINGS, NC 27592 FIELD CHANGE ORDER VIA FAX: 552-1588 ' PROJECT 0: 8-2013-A PAGE: 1 of 4 DATE: March 23, 2009 LOCATION: Pelton Residence PLANS REF: Pelton Residence for Trademark Builders, Lac by Matt Freeman Southern Engineers' Project !1: 8-2013 THE FOLLOWING CHANGE(S) OR PROPOSED CHANGE(S) LISTED BELOW ARE DEVIATIONS OR CLARIFICATIONS FOR THE ABOVE REFERENCED PLANS: Shitted Valley Support: The Roof Plan and Second Floor Play shows a (3) stud support for the valley at the front-left side of the unfinished "Storage" area that is located at the right side of the second floor. According to information provided by the builder, the 1.75x9.25 LVL valley option was installed at the referenced valley as noted on page two. Be advised that it will be structurally acceptable to shift the valley support forward to incorporate it into the 5'-0" tall kneewall as shown on page throe. The new valley support location shall be supported down to a new (2)1.75x9.25 LVL in the Laundry Room as shown on page four. Also dote that the header that is located above the pocket door at the back of the Laundry Room shall be either a minimum of a (2)2x 12 or a (2)1.75x9.25 LVL. In closing, I trust that this letter fulfills your requirements at this time. Should you have any further questions, please do not hesitate to call. `sstunrttnrri Sincerely, 1%0 Q Q'iYr Mark Minsbew, P.E. y 153 Southern Engineers, P.A. ~~tNh 3 al ,07 3716 Benson Drive RakiSk NC 27609 (919) 878-1617 (888) 200-7607 fax: (919) 873-9029 www.routhernengincers.com email: southern®southernengineers.aom £i'viSiEaaxeaacal~esa~~ea ,.",:.~,.3T»»~.~.^.~:,:• ry_ _ _ _--_-'.c-: Page: of Q ~U@rl# -rpAt)ENAzr, }~iUALDI-s5 ' i PPt9: Location: TEL-7Pt3 V->=SiDEo CE Ra r#: b_~ot?-~4 •IIII/IiI. - • "mss ~ ~i°.= ! (r , ' o A - 41 si7riNel 19 ~y 1 CiA (LiV _i wm wo r• i -~i i l //YZS2X11 CR !C~ h~., w r" 74 03/24/2009 13:38 9198739029 Sanl-ERN ENGINEERS PACE 02104 Southern Engineers 3716 Benson Or, Raleigh, NC 27609 gig/ 678-1617 page: 2 of Client: 1"DEM T-K 8cle-DERS Date: 3-.23- Location: ?El-ro RES DE14GE AIECT'4 $-aol3 A PA• tvAI- RooF PLAn1 - n - n ~ O i 7xII RIDGE g i i ~ n Ny Idy M O ~ ~ ry O lh} ~ `\\\1\111111////~ ~'Q tN GAR fQ y ° t 40 ~ g `R'~ ~`~I}if t y e nI Iv 1 \ I Date, page: Client' -1 RM-QAARB !Location: "PaRT,AL 7rva Gr vn~ 'ntq .aiat6~trerte.- C~''°s n`a' Y-e 7v°J t" .Ci'iA F'iL ! 7/f SCALE 1/+",- I' 4 - r-_m• i~ul i MF 1(3yT 1 : 3' WAIL NEIGHT I ~i r• <4_ t ! ~I ILYCIV 4LLCEi 1 I' J __-V 7-0 0' C'6 1T - jig ! 1 I s s' WAIL H£KEHYy i f J I wr Tra ti 4 564!'~3_-~73. I ! 7 Ps' 11 7 PREPARED 5A.6/Co, 13:59:38 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 5/07/09 ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR TRADEMARK BUILDERS, INC PHONE (919) 552-1588 OWNER WAVERLY DEVELOPMENT CORP #17 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 - AP TSP IS READY.********************** Tpole ok.... no premise number B103 01 2/19/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP AB14 01 2/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP 104 sherman pines dr lot 17 B105 01 2/27/09 BS R*OPEN FLOOR VRU 001739002 2/27/09 AE 1. Flash ends of drop girders. 2. extra joist missing at corner of front porch. Install (circled on plan) will check at rough in. P307 01 4/23/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001758945 4/23/09 AP R427 01 4/27/09 FOUR TRADE ROUGH IN >2500 VRU 001760230 4/27/09 DA 1. Pressure test on plumbing below 100 psi, no water in standpipe 2.Install OSB on interior garage wall per plan at garage door opening. 3. Need engineering on roof over sitting/master bath. Roof rafters / beam supported on ceiling joists. OK to side, DO NOT INSULATE R427 02 5/07/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001764893 COMMENTS AND NOTES SOUTHERN ENGINEERS James Herman, PE -Owner Consulting Structural Engineers TO: TRADEMARK BUILDERS, INC. P.O. BOX 142 WILLOW SPRINGS, NC 27592 VERIFICATION LETTER VIA EMAIL: nmclamb(d)trademarkbuilderinc.com PROJECT 8-2013-B PAGE: 1 of 1 DATE: April 30, 2009 LOCATION: Pelton Residence, Lot 17, Sherman Pines PLANS REF: Pelton Residence for Trademark Builders, Inc by Matt Freeman Southern Engineers' Project 8-2013 THE FOLLOWING CHANGE(S) OR PROPOSED CHANGE(S) LISTED BELOW ARE DEVIATIONS OR CLARIFICATIONS FOR THE ABOVE REFERENCED PLANS: Sitting Room Ceiling Joists: The First Floor Plan shows 14" wood I-Joists spanning front-to- back at 19.2" O.C. above the Sitting Room. Options for three different brands of I-Joists were provided on the plan. An offset load bearing wall above is noted to be supported by the ceiling joists. The load from above is roof load. We were made aware that the option of 14" TJI 210 I-Joists at 19.2" O.C. had been installed above the sitting room. Be advised that the 14" TH 210 I-Joists at 19.2" O.C. above the sitting room are structurally acceptable to support the offset load bearing wall above. In closing, I trust that this letter fulfills your requirements at this time. Should you have any further questions, please do not hesitate to call. ` ,,u n u n,,, Sincerely, • CAf?O~ Mark Minshew, P.E. ? aQ ES Southern Engineers, P.A. 3 = 3716 Benson Drive Raleigh, NC 27609 (919) 878-1617 (888)20D-7607 fax: (919) 873-9029 www.southernengineers.com email: southern( alsouthernengineers com PREPARED 5/15/09, 14:01:42 INSPECTION TICKET PAGE 5 ' Harnett County INSPECTOR: IVR DATE 5/18/09 'ADDRESS 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR TRADEMARK BUILDERS, INC PHONE (919) 552-1588 OWNER WAVERLY DEVELOPMENT CORP 417 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD -SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok.... no premise number B103 01 2/19/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP A814 01 2/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP 104 sherman pines dr lot 17 B105 01 2/27/09 BS - R*OPEN FLOOR VRU 001739002 2/27/09 AE 1. Flash ends of drop girders. 2. extra joist missing at corner of front porch. Install (circled on plan) will check at rough in. P307 01 4/23/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001758945 4/23/09 AP R427 01 4/27/09 BS FOUR TRADE ROUGH IN >2500 VRU 001760230 4/27/09 DA 1. Pressure test on plumbing below 100 psi, no water in standpipe 2.Install OSB on interior garage wall per plan at garage door opening. 3. Need engineering on roof over sitting/master bath. Roof rafters / beam supported on ceiling joists. OK to side, DO NOT INSULATE R427 02 5/07/09 KS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001764893 5/07/09 AP 1129 01 X5/18/09 R*INSULATION INSPECTION VRU 001769140 COMMENTS AND NOTES - PREPARED 6/29/09, 13:58:07 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 6/30/09 ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR TRADEMARK BUILDERS, INC PHONE (919) 552-1588 OWNER WAVERLY DEVELOPMENT CORP 417 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok.... no premise number B103 01 2/19/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP A814 01 2/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP 104 sherman pines dr lot 17 8105 01 2/27/09 BS R*OPEN FLOOR VRU 001739002 2/27/09 AE 1. Flash ends of drop girders. 2. extra joist missing at corner of front porch. Install (circled on plan) will check at rough in. P307 01 4/23/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001758945 4/23/09 AP R427 01 4/27/09 BS FOUR TRADE ROUGH IN >2500 VRU 001760230 4/27/09 DA 1. Pressure test on plumbing below 100 psi, no water in standpipe 2.Install OSB on interior garage wall per plan at garage door opening. 3. Need engineering on roof over sitting/master bath. Roof rafters / beam supported on ceiling joists. OK to side, DO NOT INSULATE R427 02 5/07/09 KS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001764693 5/07/09 AP 1129 01 5/18/09 BS R*INSULATION INSPECTION VRU 001769140 5/18/09 AP M305 01 09 TI R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001788298 /3~dQ W T/S: 06/29/2009 12:10 PM NTART COMMENTS AND NOTES PREPARED 7/30/09, 13:59:00 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 7/31/09 ADDRESS 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACF.0R TRADEMARK BUILDERS, INC PHONE (919) 552-1588 OWNER AVERLY DEVELOPMENT CORP #17 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) DIRECTIONS : SHERMAN PINES #17 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok.... no premise number B103 01 2/19/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP A814 01 2/19/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP V104 sherman pines dr lot 17 B105 01 2/27/09 BS R*OPEN FLOOR VRU 001739002 2/27/09 AE 1. Flash ends of drop girders. 2. extra joist missing at corner of front porch. Install (circled on plan) will check at rough in. P307 01 4/23/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001758945 4/23/09 AP R427 01 4/27/09 BS FOUR TRADE ROUGH IN >2500 VRU 001760230 4/27/09 DA 1. Pressure test on plumbing below 100 psi, no water in standpipe 2.Install OSB on interior garage wall per plan at garage door opening. 3. Need engineering on roof over sitting/master bath. Roof rafters / beam supported on ceiling joists. OK to side, DO NOT INSULATE R427 02 5/07/09 KS FOUR TRADE ROUGH IN >2500 'TIME: 17:00 VRU 001764893 5/07/09 AP 1129 01 5/18/09 BS R*INSULATION INSPECTION VRU 001769140 5/16/09 AP M305 01 6/30/09 BS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001788298 6/30/09 AP T/S: 06/29/2009 12:10 PM NTART R431 01 7/28/09 TI FOUR TRADE FINAL >2500 VRU 001801075 7/27/09 CA T/S: 07/27/2009 02:27 PM NTART CANCELLED FINAL INSPECTION. NO OPERATIONS PERMIT. NJT------ H824 01 7/29/09 OT NoENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001802636 7/29/09 AP T/S: 07/30/2009 10:28 AM SSTEWART T/S: 07/30/2009 10:26 AM SSTEWART - - - - CONTINUED ONTO NEXT PAGE - PREPARED 7/30/09, 13:59:00 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR -DATE 7/31/09 - - - - ADDRESS . : 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR : yyTRADEMARK BUILDERS, INC PHONE (919) 552-1588 OWNER f'. :'WAVERLY DEVELOPMENT CORP #17 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020621 CP NEW RESIDENTIAL (SFD) - - - - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - R431 02 7/31/09 T FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001802784 T/S: 07/30/2009 11:23 AM RDCONTE COMMENTS AND NOTES PREPARED 8/04/09, 14:22:02 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 8/05/09 ADDRESS 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR 'W TRADEMARK BUILDERS, INC PHONE (919) 552-1588 "OWNER WAVERLY DEVELOPMENT CORP #17 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) - DIRECTIONS : SHERMAN PINES 417 NC 401 NORTH, HEADING THROUGH CHALYBEATE SPRINGS YOU WILL PASS THROUGH THE INTERSECTION WITH RAWLS CHURCH ROAD AND THEN MAKE YOUR 2ND LEFT ONTO SHERMAN PINES ROAD. THE LOT IS THE 3RD ON THE RIGHT, JUST BEFORE FIRST HOME ON RIGHT. T/S: 08/28/2008 08:50 AM RDCONTE PREMISE # 60309054******************* STRUCTURE: 000 000 90X55 CRAWL 4BED W/ GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 1/30/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001730159 1/30/09 AP TSP IS READY.********************** Tpole ok.... no premise number B103 01 2/19/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001735950 2/19/09 AP A814 01 2/19/09 TI DRESS CONFIRMATION TIME: 17:00 VRU 001735968 2/19/09 AP 104 sherman pines dr lot 17 B105 01 2/27/09 BS R*OPEN FLOOR VRU 001739002 2/27/09 AE 1. Flash ends of drop girders. 2. extra joist missing at corner of front porch. Install (circled on plan) will check at rough in. P307 01 4/23/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001758945 4/23/09 AP R427 01 4/27/09 BS FOUR TRADE ROUGH IN >2500 VRU 001760230 4/27/09 DA 1. Pressure test on plumbing below 100 psi, no water in standpipe 2.Install OSB on interior garage wall per plan at garage door opening. 3. Need engineering on roof over sitting/master bath. Roof rafters / beam supported on ceiling joists. OK to side, DO NOT INSULATE R427 02 5/07/09 KS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001764893 5/07/09 AP 1129 01 5/18/09 BS R*INSULATION INSPECTION VRU 001769140 5/18/09 AP M305 01 6/30/09 BS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001788298 6/30/09 AP T/S: 06/29/2009 12:10 PM NTART R431 01 7/28/09 TI FOUR TRADE FINAL >2500 VRU 001801075 7/27/09 CA T/S: 07/27/2009 02:27 PM NTART ANCELLED FINAL INSPECTION. NO OPERATIONS PERMIT. NJT------ H824 01 7/29/09 OT \[ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001802636 7/29/09 AP T/S: 07/30/2009 10:28 AM SSTEWART T/S: 07/30/2009 10:28 AM SSTEWART - - - - CONTINUED ONTO NEXT PAGE - - - PREPARED 8/04/09, 14:22:02 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 8/05/09 -------.-i------------------ - - - - ADDRESS- 104 SHERMAN PINES DR SUBDIV: SHERMAN PINES CONTRACTOR'S TRADEMARK BUILDERS, INC PHONE (919) 552-1588 -OWNER WAVERLY DEVELOPMENT CORP #17 PHONE PARCEL 08-0655- - -0118- -53- APPL NUMBER: 08-50020821 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R431 02 7/31/09 BS FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001802784 7/31/09 DA T/S: 07/30/2009 11:23 AM RDCONTE 1. Must have address posted on structure in addition to posting at drive entrance. 2. Receptacle missing in upstairs room beside patio door. Possibly covered by sheetrock. 3.Close off foundation vent at ramp with a suitable means. Cannot use aluminum flashing against brick/concrete. Also, closure must be sealed and watertight. Call to reschedule. R431 03 8/04/09 FOUR TRADE FINAL >2500 VRU 001804327 8/04/09 DP previous violations not corrected $50 re fee---- R431 04 8/05/09 ft~" FOUR TRADE FINAL >2500 VRU 001804988 S-- to 9 - COMMENTS AND NOTES - - - - M. Nk COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Cade and the Harnett County Zoning Ordinance cues at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the fallowing: Use Classification: SFD Conditional Use Permit No.: NA Type of Construction: V _ Building Permit No.: 0B-50020821 Owner of Building: Waverly Dev. Corp Electrical Permit No.: OB-50020821 Building Address: 104 Sherman Pines Drive Insulation Permit No.: 08-50020B21 Zoning District: NA Plumbing Permit No.: 08-50020821 Zoning Permit No.: NA Mech. Permit No.: 0B-5002OB21 ,coy, Date: 08/05/09 Envic C.O. No.: 08-50020821 Brad Sutton NA Building Official Zoning Official