INSPECTIONS PREPARED 12/18/08, 14:53:14 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 12/19/08 ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR : HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER : HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL : 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL - DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000,36X76 BRICXMA.SON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 12/19/08 TI C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 -A 12- fil 12 PERMIT: CPPC00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED- RESULT RESULTS/COMMENTS - - P357 01 12/19/08 TI C*PLUMB UNDER SLAB TIME: 17:00 VRU 001719517 ae-M COMMENTS AND NOTES PREPARED 12/22/08, 14:08:40 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 12/23/08 ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 3GX76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - C155 01 12/23/08 C*BLDG FOUNDATION VRU #:-001720523 M~`~ 4r COMMENTS AND NOTES PREPARED 12/29/08, 14:01:03 INSPECTION TICKET PAGE 29 Harnett County INSPECTOR: IVR DATE 12/30/08 - - ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - C155 01 12/23/08 JH C*BLDG FOUNDATION VRU 001720523 12/23/08 DA not ready for inspection C159 01 12/30/08 TI_ C*BLDG SLAB INSP VRU 001721281 COMMENTS AND NOTES - - - - - PREPARED 5/19/09, 13:58:47 INSPECTION TICKET PAGE 4 Harnett County; INSPECTOR: IVR DATE 5/20/09 t ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C155 01 12/23/08 JH C*BLDG FOUNDATION VRU 001720523 12/23/08 DA not ready for inspection C159 01 12/30/08 JH C*BLDG SLAB INSP VRU 001721281 12/30/08 AP - C153 01 5/20/09 TI C*BLDG ROUGH IN VRU 001770247 S 20•x+ DA-M~Z PERMIT: OPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 12/19/08 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 12/19/08 AP underground E251 01 5/20/09 TI C*ELEC ROUGH IN VRU 001770254 5.20.2 ~ UA- PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M459 01 5/20/09 T~ v C*MECH ROUGH IN VRU 001770262 20.°) PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED - INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 12/19/08 MR C*PLUMB UNDER SLAB TIME: 17:00 VRU 001719517 12/19/08 AP P351 01 5/20/09 TI „ C*PLUMB ROUGH IN VRU 001770270 S'2afl COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 05-20-09 PERMIT# 08-50021009 ADDRESS: 2495 ray rd VIOLATIONS: 1. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible 5. Finish window framing in batrhroom 6. Finish vents through roof on plumbing 7. Need water in test on plmb. 8. Need pressure test on water pipes on plmb 9. NEC 250.64E requires bonding of grounding conductors at both ends when installed in a metal pipe. Harnett County Building Department Mike Reatic cell# (910) 984- 4772 PREPARED 5/21/09, 14:10:00 INSPECTION TICKET PAGE 2 HzT7nett Cohnty INSPECTOR: IVR DATE 5/22/09 - - - - - ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR : HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER- : HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL : 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTUR.E: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C155 01 12/23/08 JH C*BLDG FOUNDATION VRU 001720523 12/23/08 DA not ready for inspection C159 01 12/30/08 JH C*BLDG SLAB INSP VRU 001721281 12/30/08 AP . C153 01 5/20/09 MR C*BLDG ROUGH IN VRU 001770247 5/20/09 DA @.. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installationsQO- NEC 314-P& Plastic boxes not permitted. Qhwj, LB type boxes cannot be installed behind drywall. They must be Accessible-S- Finish window framing in batrhroom Finish vents through roof on plumbing "1►. Need water in test on plmb. C153 02 5/22/09 TI C*BLDG ROUGH IN VRU 001771369 ,9--2-2.9 DA-M(7~_ - CONTINUED ONTO NEXT PAGE - PREPARED 5/21/09, 14:10:00 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 5/22/09 ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR : HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER- : HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL : 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICRMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 12/19/08 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 12/19/08 AP underground E251 01 5/20/09 MR C*ELEC ROUGH IN VRU 001770254 5/20/09 DA 1. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible 5. Finish window framing in batrhroom 6. Finish vents through roof on plumbing 7. Need water in test on plmb. 8. Need pressure test on water pipes on plmb 9. NEC 250.64E requires bonding of grounding conductors at both ends when installed in a metal pipe. E251 02 5/22/09 TI C*ELEC ROUGH IN VRU 001771377 CONTINUED ONTO NEXT PAGE PREPARn 5/21/09, 14:10:00 INSPECTION TICKET PAGE 4 Harriett CMnty INSPECTOR: IVR DATE 5/22/09 ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 12/19/08 MR C*PLUMB UNDER SLAB TIME: 17:00 VRU 001719517 12/19/08 AP P351 01 5/20/09 MR C*PLUMB ROUGH IN VRU 001770270 5/20/09 DA P351 02 5/22/09 TI C*PLUMB ROUGH IN VRU 001771385 COMMENTS AND NOTES PREPARED 5/26/09, 14:00:10 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 5/27/09 ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CPEC 00 CP ELECTRICAL COMMERCTAT• REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 12/19/08 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 12/19/08 AP underground E251 01 5/20/09 MR C*ELEC ROUGH IN VRU 001770254 5/20/09 DA 1. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible 5. Finish window framing in batrhroom 6. Finish vents through roof on plumbing 7. Need water in test on plmb. 8. Need pressure test on water pipes on plmb 9. NEC 250.64E requires bonding of grounding conductors at both ends when installed in a metal pipe. E251 02 5/22/09 MR C*ELEC ROUGH IN VRU 001771377 5/22/09 DA 14 2:,~-=r white conductors cannot be used for hot cou""OZA E251 03 5/27/09 TI C*ELEC ROUGH IN VRU 001772441 X27 9 4p_t COMMENTS AND NOTES - - 1 PREPARED 7/2j)/09, 13:59:34 INSPECTION TICKET PAGE 9 Harnett Cou(I, INSPECTOR: IVR DATE 7/21/09 r _ - ADDRESS 5 RAY RD MAIN BLDG SUBDIV: CONTRAC~'OR RNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER -O VERHILLS HIGH-HRICKMASON PHONE (910) 893-8151 PARCEL . . : 01-0513- - - 0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 12/19/08 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 12/19/08 AP underground E251 01 5/20/09 MR C*ELEC ROUGH IN VRU 001770254 5/20/09 DA 1. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible 5. Finish window framing in batrhroom 6. Finish vents through roof on plumbing 7. Need water in test on plmb. 8. Need pressure test on water pipes on plmb 9. NEC 250.64E requires bonding of grounding conductors at both ends when installed in a metal pipe. E251 02 5/22/09 MR C*ELEC ROUGH IN VRU 001771377 5/22/09 DA NEC 200.7 white conductors cannot be used for hot conductors E251 03 5/27/09 MR C*ELEC ROUGH IN VRU 001772441 5/27/09 AP E257 02 7/21/09 TI C*ELEC OVERHEAD TIME: 17:00 VRU 001796887 7- 2- 1-*~ /7Q- Mt2 T/S: 07/20/2009 08:15 AM JBROCK PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - M459 01 5/20/09 MR C*MECH ROUGH IN VRU 001770262 5/20/09 AP M463 01 7/21/09 TI C*MECH OVERHEAD TIME: 17:00 VRU 001796903 7-21-9 T/S: 07/20/2009 08:16 AM JBROCK PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 12/19/08 MR C*PLUMB UNDER SLAB TIME: 17:00 VRU 001719517 12/19/08 AP - - CONTINUED ONTO NEXT PAGE - PREPARED 7/20/09, 13:59:34 INSPECTION TICKET PAGE 10 Harnett Countz INSPECTOR: IVR DATE 7/21/09 -----------j - - - ADDRESS`2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4806 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL . REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P351 01 5/20/09 MR C*PLUMB ROUGH IN VRU 001770270 5/20/09 DA P351 02 5/22/09 MR C*PLUMB ROUGH IN VRU 001771385 5/22/09 AP P359 01 7/21/09 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001796911 2•(• D A -MFZ T/S: 07/20/2009 08:16 AM JBROCK - - COMMENTS AND NOTES - HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 07-21-09 PERMIT # 08-50021009 ADDRESS: 2495 Ray Rd. VIOLATIONS: 1. Fire rated mechanical penetrations are not installed per drawings 2. Pull back insulation from gas heater flues at roof and install insulation shields and provide manufacturers specs. on required distance 3. Architect specifies aluminum facing on all exposed insulation(sheet 6- note 1-C) If this is a change provide letter 4. Install and wire the water heater Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 8/03/09, 13:59:31 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: (IVR DATE 8/04/09 ADDRESS . : 2495 RPOY RD MAIN BLDG SU13DIV: CONTRACTOR HA$NET7,+ COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - - 0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERBILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2DO8 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 12/19/08 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 12/19/08 AP underground E251 01 5/20/09 MR C*ELEC ROUGH IN VRU 001770254 5/20/09 DA 1. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible S. Finish window framing in batrhroom 6. Finish vents through roof on plumbing 7. Need water in test on plmb. 8. Need pressure test on water pipes on plmb 9. NEC 250.64E requires bonding of grounding conductors at both ends when installed in a metal pipe. E251 02 5/22/09 MR C*ELEC ROUGH IN VRU 001771377 5/22/09 DA NEC 200.7 white conductors cannot be used for hot conductors E251 03 5/27/09 MR C*ELEC ROUGH IN VRU 001772441 5/27/09 AP E257 02 7/21/09 C*ELEC OVERHEAD TIME: 17:00 VRU 001796887 7/21/09 DA T/S: 07/20/2009 06:15 AM JBROCK T/S: 07/21/2009 02:28 PM MREARIC water heater over bathroom is not wired E257 03 8/04/09 TI V/C*ELEC OVERHEAD TIME: 17:00 VRU 001804129 4,9 $ T/S: 08/03/2009 11:32 AM JBROCK PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M459 01 5/20/09 MR C*MECH ROUGH IN VRU 001770262 5/20/09 AP M463 01 7/21/09 C*MECH OVERHEAD TIME: 17:00 VRU 001796903 7/21/09 DA T/S: 07/20/2009 08:16 AM JBROCK T/S: 07/21/2009 02:29 PM MREARIC 1. fire damper collars are not instalkled through wall per plans CONTINUED ONTO NEXT PAGE PREPARED 8/03/09, 13:59:31 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 8/04/09 - - - - - ADDRESS . : 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNET-.COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCB~-OVRHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 2. pull back insulation at flues on heaters and install insulation shields and provide manuf. specs on installation M459 02 8/04/09 TI C*MECH ROUGH IN TIME: 17:00 VRU 001804137 8 ,g -9 j P-Mr,, T/S: 08/03/2009 11:32 AM JBROCK PERMIT: CPPC 00 CP PLUMING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 12/19/08 MR C*PLUMB UNDER SLAB TIME: 17:00 VRU 001719517 12/19/08 AP P351 01 5/20/09 MR C*PLUMB ROUGH IN VRU 001770270 5/20/09 DA P351 02 5/22/09 MR C*PLUMB ROUGH IN VRU 001771385 5/22/09 AP P359 01 7/21/09 C*PLUMB OVERHEAD TIME: 17:00 VRU 001796911 7/21/09 DA T/S: 07/20/2009 08:16 AM JBROCK T/S: 07/21/2009 02:31 PM MREARIC install water heater P359 02 8/04/09 TI JC*PLUMB OVERHEAD TIME: 17:00 VRU 001804152 6,-1,9 ~-.T/S: 08/03/2009 11:32 AM JBROCK - COMMENTS AND NOTES PREPARED 8/04/09, 14:22:02 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 8/05/09 J ADDRESS 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERHILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICKMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 12/19/08 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 12/19/08 AP underground E251 01 5/20/09 MR C*ELEC ROUGH IN VRU 001770254 5/20/09 DA 1. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible 5. Finish window framing in batrhroom 6. Finish vents through roof on plumbing 7. Need water in test on plmb. 8. Need pressure test on water pipes on plmb 9. NEC 250.64E requires bonding of grounding conductors at both ends when installed ina metal pipe. E251 02 5/22/09 MR C*ELEC ROUGH IN VRU 001771377 5/22/09 DA NEC 200.7 white conductors cannot be used for hot conductors E251 03 5/27/09 MR C*ELEC ROUGH IN VRU 001772441 5/27/09 AP E257 02 7/21/09 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001796887 7/21/09 DA T/S: 07/20/2009 08:15 AM JBROCK T/S: 07/21/2009 02:28 PM MREARIC water heater over bathroom is not wired E257 03 8/04/09 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001804129 8/04/09 AP T/S: 08/03/2009 11:32 AM JBROCK T/S: 08/04/2009 01:10 PM MREARIC E267 01 8/05/09 TI_ C*ELEC TEMP SERVICE POLE VRU 001804947 ------------------OMMENTS J;r N TES C ~q lease kCt) "~FOPwnyy' ymy°m..'~'4S ~p'nt~-fuT'A'yy4ri~ V3+:sP..,v.~,l'fi5~' A.P}+311'~:~J".t`~y,ayw'+n'qr~`y'KY"°f4~i'm"1~Z'•9.°41"}'Msnryi.'"h5C4*' ~n~%.~.'.•i.yr.vu . ~r"v'kN"hh•NY'a`v'^~.`P~~" EXPIRL DATE O T 5110 TEMPORARY POWER CERTIFICATE JOB NAME QIlerL)tS 9f* Sclool " rLeW I~r;~kvuasok ~l~ol OWNER ADDRESS PHONE / LOCATION f SY The power company shall not be required to terminate electric service supplied to the premises described above on or after the expiration date specified in this certificate, unless and until it is notified in, writing by the Harnett County Electrical Inspector to do so. s I the undersigned understand that this certificate is for Temporary Power only and that a final inspection is required before permanent power will be approved. I; shall also comply with any special requirement requested by the Harnett County Inspection Department. J1~1nn//,, ss. Date Owner or Authorized Signature This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code certifying at the time of issuance this structure was in temporary compliance with the various ordinances of the County of Harnett regulating building construction or use. ~A- Date Building Official PREPARED 8/11/09, 14:51:16 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 8/12/09 ADDRESS- 2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL DIRECTIONS : OVERHILLS HIGH SCHOOL 210 SOUTH APPROX 14 MILES THEN RIGHT ONTO RAY RD OVERBILL HIGH IS 2.5 MILES ON LEFT. T/S: 09/29/2008 12:56 PM DJOHNSON STRUCTURE: 000 000 36X76 BRICXMASON CLASSROOM/SHOP BLDG FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : SHOP SEPTIC - EXISTING? . . . . : NA PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - C155 01 12/23/08 JH C*BLDG FOUNDATION VRU 001720523 12/23/08 DA not ready for inspection C159 01 12/30/08 JH C*BLDG SLAB INSP VRU 001721281 12/30/08 AP C153 01 5/20/09 MR C*BLDG ROUGH IN VRU 001770247 5/20/09 DA 1. NEC 250.90B bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible 5. Finish window framing in batrhroom 6. Finish vents through roof on plumbing 7. Need water in test on plmb. C153 02 5/22/09 MR C*BLDG ROUGH IN VRU 001771369 5/22/09 AP F854 01 8/11/09 JB FM*FINAL INSPECTION TIME: 17:00 VRU 001807775 8/11/09 AP T/S: 08/11/2009 01:59 PM JBROCK INSPECTION BY DAVE W/ FM T/S: 08/11/2009 02:00 PM JBROCK C179 01 8/12/09 TI C*BLDG FINAL TIME: 17:00 VRU 001807841 pia ~q T/S: 08/11/2009 02:50 PM NTART PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - E257 01 12/19/08 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001719715 12/19/08 AP underground E251 01 5/20/09 MR C*ELEC ROUGH IN VRU 001770254 5/20/09 DA 1. NEC 250.908 bonding bushings are required at meter on both steel pipes 2. NEC 200.6 white conductors cannot be used as travelers or switch-legs except for romex installations 3. NEC 314.3 Plastic boxes not permitted. 4. LB type boxes cannot be installed behind drywall. They must be Accessible 5. Finish window framing in batrhroom 6. Finish vents through roof on plumbing - - CONTINUED ONTO NEXT PAGE PREPARED 8/11/09, 14:51:16 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 8/12/09 ADDRESS- . :,495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-8151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 7. Need water in test on plmb. 8. Need pressure test on water pipes on plmb 9. NEC 250.64E requires bonding of grounding conductors at both ends when installed in a metal pipe. E251 02 5/22/09 MR C*ELEC ROUGH IN VRU 001771377 5/22/09 DA NEC 200.7 white conductors cannot be used for hot conductors E251 03 5/27/09 MR C*ELEC ROUGH IN VRU 001772441 5/27/09 AP E257 02 7/21/09 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001796887 7/21/09 DA T/S: 07/20/2009 08:15 AM JBROCK T/S: 07/21/2009 02:28 PM MREARIC water heater over bathroom is not wired E257 03 8/04/09 MR C*ELEC OVERHEAD TIME: 17:00 VRU 001804129 8/04/09 AP T/S: 08/03/2009 11:32 AM JBROCK T/S: 08/04/2009 01:10 PM MREARIC E267 01 8/05/09 MR C*ELEC TEMP SERVICE POLE VRU #c 001604947 8/05/09 AP T/S: 08/05/2009 11:12 AM MREARIC temporary electrical final E265 01 8/12/09 TI_ C*ELEC FINAL TIME: 17:00 VRU 001807874 - :~f~ T/S: 08/11/2009 02:50 PM NTART PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - M459 01 5/20/09 MR C*MECH ROUGH IN VRU 001770262 5/20/09 AP M463 01 7/21/09 MR C*MECH OVERHEAD TIME: 17:00 VRU 001796903 7/21/09 DA T/S: 07/20/2009 08:16 AM JBROCK T/S: 07/21/2009 02:29 PM MREARIC 1. fire damper collars are not instalkled through wall per plans 2. pull back insulation at flues on heaters and install insulation shields and provide manuf. specs on installation M459 02 8/04/09 MR C*MECH ROUGH IN TIME: 17:00 VRU 001804137 8/04/09 AP T/S: 08/03/2009 11:32 AM JBROCK T/S: 08/04/2009 01:10 PM MREARIC M465 01 8/G lz/o9 C*MECH FINAL TIME: 17:00 VRU 001807882 T/S: 06/11/2009 02:50 PM NTART PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - P357 01 12/19/08 MR C*PLUMB UNDER SLAB TIME: 17:00 VRU 001719517 12/19/08 AP CONTINUED ONTO NEXT PAGE - - PREPARED 8/11/09, 14:51:16 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 8/12/09 - - - ADDRESS- . :•2495 RAY RD MAIN BLDG SUBDIV: CONTRACTOR HARNETT COUNTY SCHOOLS PHONE (910) 893-4808 OWNER HCBE-OVERHILLS HIGH-BRICKMASON PHONE (910) 893-6151 PARCEL 01-0513- - -0201- - - APPL NUMBER: 08-50021009 CP NEW SCHOOLS & EDUCATIONAL - - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - P351 01 5/20/09 MR C*PLUMB ROUGH IN VRU 001770270 5/20/09 DA P351 02 5/22/09 MR C*PLUMB ROUGH IN VRU 001771385 5/22/09 AP P359 01 7/21/09 MR C*PLUMB OVERHEAD TIME: 17:00 VRU 001796911 7/21/09 DA T/S: 07/20/2009 08:16 AM JBROCK T/S: 07/21/2009 02:31 PM MREARIC install water heater P359 02 8/04/09 MR C*PLUMB OVERHEAD TIME: 17:00 VRU 001804152 8/04/09 AP T/S: 06/03/2009 11:32 AM JBROCK T/S: 08/04/2009 01:10 PM MREARIC P361 01 8/12/09 T C*PLUMB FINAL TIME: 17 VRU 001807890 " T/S: 08/11/2009 02:50 PM NTART COMMENTS AND NOTES - Off ~.a+P } P M E 1 o t fir,, k n k COUNTY OF HARNETT fJ DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY l a This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in, compliance with the various ordinances of the County of Harnett regulating development and building J construction or use. For the following: 1 ,1711\ Use Classification: 1U('4 1 o /kq PERMIT NUMBERS ! Owner: Building Permit No.: FJ 911 Address: 1 Electrical Permit No.: a Insulation Permit No.: Plumbing Permit No.: I I 30 0,/OO State: Zip Code: Mech. Permit No.: Y;>Q- Ic,, Dater - Y MFG. Home: - 111f u p,,Building) icial x ate ,I