INSPECTIONS
PREPARED 7/02/08, 14:31:32 INSPECTION TICKET PAGE 27
Harnett County INSPECTOR: IVR DATE 7/03/08
ADDRESS . : 2546 BYRDS MILL RD SU13DIV:
CONTRACTOR : PHONE
OWNER MATTHEWS DEMETRIC S & BERDINA PHONE (910) 980-0552
PARCEL 12-0576- - -0022- -25-
APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 157 GREENCREST DRIVE LINDEN 28356.
COWAN SUB DIV SEC II LOT#10. GO DOWN
4015 TOWARDS FYETTEVEILLE, GO THROGH
THE TOWN OF BUNNLEVEL, COME TO
PLANTATION ON THE,LEFT, BARE TO THE
LEFT AT THE PLANTATION HOUSE, THAT IS
BYRDS MILL RD, MY LOT IS THE LAST LOT
ACROSS FROM LAST TWO SWMH ON THE LEFT.
T/S: 02/21/2008 08:14 AM VBROWN
STRUCTURE: 000 000 73X5316.5" 4BDR. 3.5$ATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/03/08 R*BLDG FOOTING / TEMP SVC POLE VRU 001635812
- - COMMENTS AND NOTES
PREPARED 7/07/08, 14:04:58 INSPECTION TICKET PAGE 23
Harnett County INSPECTOR: IVR DATE 7/08/08
- - - - - - -
ADDRESS . : 2546 BYRDS MILL RD SUBDIV:
CONTRACTOR : PHONE
OWNER MATTHEWS DEMETRIC S & BERDINA PHONE (910) 980-0552
PARCEL 12-0576- - -0022- -25-
APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 157 GREENCREST DRIVE LINDEN 28356.
COWAN SUB DIV SEC II LOT#10. GO DOWN
4015 TOWARDS FYETTEVEILLE, GO THROGH
THE TOWN OF BUNNLEVEL, COME TO
PLANTATION ON THE LEFT, BARE TO THE
LEFT AT THE PLANTATION HOUSE, THAT IS
BYRDS MILL RD, MY LOT IS THE LAST LOT
ACROSS FROM LAST TWO SWMH ON THE LEFT.
T/S: 02/21/2008 08:14 AM VBROWN
STRUCTURE: 000 000 73X5316.50 4BDR 3.SBATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - - - - -
B101 01 7/03/08 JH R*BLDG FOOTING / TEMP SVC POLE VRU 001635812
7/03/08 AP no t-pole
A814 01 7/08/08 TI ADDRESS CONFIRMATION VRU 001637750
B103 01 7/~ 08/08 R*BLDG FOUND & TEMP SVC POLE VRU 001637768
- - - COMMENTS AND NOTES - - -
24
PREPARED 7/18/08, 14:00:39 INSPECTION TICKET PAGE 14
Harnett County INSPECTOR: IVR DATE 7/21/08
ADDRESS . : 2546 BYRDS MILL RD SUBDIV:
CONTRACTOR : PHONE :
OWNER MATTHEWS DEMETRIC S & BERDINA PHONE : (910) 980-0552
PARCEL 12-0576- - -0022- -25-
APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 157 GREENCREST DRIVE LINDEN 28356.
COWAN SUB DIV SEC II LOT410. GO DOWN
4015 TOWARDS FYETTEVEILLE, GO THROGH
THE TOWN OF BUNNLEVEL, COME TO
PLANTATION ON THE LEFT, BARE TO THE
LEFT AT THE PLANTATION HOUSE, THAT IS
BYRDS MILL RD, MY LOT IS THE LAST LOT
ACROSS FROM LAST TWO SWMH ON THE LEFT.
T/S: 02/21/2008 08:14 AM VBROWN
STRUCTURE: 000 000 73X5316.5" 413DR 3.SBATH SFD
FLOOD ZONE . . . . FLOOD ZONE X
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - -
B101 01 7/03/08 JH R*BLDG FOOTING / TEMP SVC POLE VRU 001635812
7/03/08 AP no t-pole
A814 01 7/08/08 TI ADDRESS CONFIRMATION VRU 001637750
7/10/08 AP 2546 BYRDS MILL RD LOT 10
B103 01 7/08/08 KS R*BLDG FOUND & TEMP SVC POLE VRU 001637768
7/08/08 AP
E207 01 7/21/08 I ~p R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 0011664/5316
COMMENTS AND NOTES -.(r L^
PREPARED 7/30/08, 14:01:32 INSPECTION TICKET PAGE 22
Harnett County INSPECTOR: IVR DATE 7/31/08
ADDRESS . : 2546 BYRDS MILL RD SUBDIV:
CONTRACTOR : PHONE
OWNER MATTHEWS DEMETRIC S & BERDINA PHONE (910) 980-0552
PARCEL 12-0576- - -0022- -25-
APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 157 GREENCREST DRIVE LINDEN 28356.
COWAN SUB DIV SEC II LOT#10. GO DOWN
4015 TOWARDS FYETTEVEILLE, GO THROGH
THE TOWN OF BUNNLEVEL, COME TO
PLANTATION ON THE LEFT, BARE TO THE
LEFT AT THE PLANTATION HOUSE, THAT IS
BYRDS MILL RD, MY LOT IS THE LAST LOT
ACROSS FROM LAST TWO SWMH ON THE LEFT.
T/S: 02/21/2008 08:14 AM VBROWN
PREMISE # 28980232
STRUCTURE: 000 000 73%53'6.5" 4BDR 3.5BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-
B101 01 7/03/08 JH R*BLDG FOOTING / TEMP SVC POLE VRU 001635812
7/03/08 AP no t-pole
A814 01 7/08/08 TI ADDRESS CONFIRMATION VRU 001637750
7/10/08 AP 2546 BYRDS MILL RD LOT 10
B103 01 7/08/08 KS R*BLDG FOUND & TEMP SVC POLE VRU 001637768
7/08/08 AP
E207 01 7/21/08 JH R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001645316
7/21/08 AP
B105 01 7/30/08 TI R*OPEN FLOOR VRU 001651306
7/29/08 CA
B105 02 7/31/08 T R*OPEN FLOOR TIME: 17:00 VRU 001653104
COMMENTS AND NOTES -
PREPARED 1,/7.4/09, 1359:14 INSPECTION TICKET PAGE 5
Harnett County INSPECTOR: IVR DATE 1/15/09
ADDRESS . : 2546 BYRDS MILL RD SUBDIV:
CONTRACTOR : PHONE :
"OWNER :MATTHEWS DEMETRIC S & BERDINA PHONE : (910) 980-0552
PARCEL : 12-0576- - -0022- -25-
APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 157 GREENCREST DRIVE LINDEN 28356.
COWAN SUB DIV SEC II LOT#10. GO DOWN
4015 TOWARDS FYETTEVEILLE, GO THROGH
THE TOWN OF BUNNLEVEL, COME TO
PLANTATION ON THE LEFT, BARE TO THE
LEFT AT THE PLANTATION HOUSE, THAT IS
BYRDS MILL RD, MY LOT IS THE LAST LOT
ACROSS FROM LAST TWO SWMH ON THE LEFT.
T/S: 02/21/2008 08:14 AM VBROWN
PREMISE # 28980232
*JIMMY NEEDS ALL THE ROOF TRUSS PAPERWO
STRUCTURE: 000 000 73%53'6.5" 4BDR 3.5BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/03/08 JH R*BLDG FOOTING / TEMP SVC POLE VRU 001635812
7/03/08 AP no t-pole
A814 01 7/08/08 TI ADDRESS CONFIRMATION VRU 001637750
7/10/08 AP 2546 BYRDS MILL RD LOT 10
B103 01 7/08/08 KS R*BLDG FOUND & TEMP SVC POLE VRU 001637768
7/08/08 AP
E207 01 7/21/08 JH R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001645316
7/21/08 AP
B105 01 7/30/08 TI R*OPEN FLOOR VRU 001651306
7/29/08 CA
B105 02 7/31/08 JH R*OPEN FLOOR TIME: 17:00 VRU 001653104
7/31/08 AP
R427 01 10/20/08 JH FOUR TRADE ROUGH IN >2500 VRU 001693902
10/20/08 CA per Demetric
R427 02 1/09/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001723980
1/08/09 CA
R427 03 1/12/09 TI FOUR TRADE ROUGH IN >2500 VRU 001724491
1/09/09 CA CA PER CUSTOMER CALLING IN
R427 04 (I1 (/(155 6//009 9 T FOUR TRADE ROUGH IN >2500 VRU 001725704
- COMMENTS AND NOTES - -
_83x
Fu,dws 114 - -
Ji 9T6 111592009 1¢2x38AM'
..Application number, type - ` - r: 0850019171 CP NEW RESIDENTIAL (SI7DI
Property address - 2546 BYRDS MILL RD
1. Need to fire block top plate where wall was furred for
plumbing near stairs.
2. Attic access must be moved, catwalk not clear to unit.
3. Trusses 6, 7, 32, 38, and 61 need web braces/atronabacks.
Okay to side and insulate.
i
3
r -OK Etlil Cg~a:el I_ rte,: l loser[ r Qeleta Iirna, stamp 1lm defaut s
Print Page 1 of I
From: Steve Tuma (landmark@lhlc.com)
To: 'demetric matthews'
Date: Monday, January 12, 2009 4:08:33 PM
Subject: anchor bolt situation
Demetric, just got the following note from the engineer:
"We suggest that the homeowner install some sort of epoxy anchor bolt product that
satisfies local code. For this type of system, he would basically be drilling holes in
the top of his foundation (spacing per code) and installing new bolts with an epoxy
application. It seems that a wedge anchor would be likely to blow off the side of the
concrete block."
This is their opinion based on the general situation. This is a typical repair. As
the foundation was modified from the plan provided, our engineers cannot accurately
provide a letter as to the specific repair. It seems as if your foundation installer
made modifications to the design we had on the plans so it would-be best for him to
provide the documentation and substantiate his changes. It would be very hard for us
to determine what was actually installed on site.
We believe that you should be able to get this approved by the building inspector as
this is a typical repair for this type of a situation. Anchor bolt issues like this
arise occasionally and the epoxy anchor bolt repair is generally accepted.
Steve
Steve Tuma
Landmark Home & Land Co,Inc.
PO Box 9118,
Michigan City, IN 46361
Telephone: 800-396-5556
Fax: 800-964-2076
Web site: www.lhlc.com
Email: landmark@lhlc.com
http://us.rng2.maii.yahoo.com/dc/launch?action=showLetter&umid=l _70538_ADZu°/`2F... 1/13/2009
i
- YOUR TR US$ COMPANY
Aurialffinv stiseoms
From the Desk of Steve Blinn
Steve Tuma
Landmark Home & Land
Re: Matthews Residence, North Carolina
12-4-08
Steve,
I have reviewed the pictures sent to us by Mr. Matthews in regards to his framing. Most
of the LVL beams he has documented are OK with no modifications being made. I aryl
including a layout of the first floor of the house with beam bearing conditions marked A-
D. Corresponding pictures from Mr. Matthews are also included. These notches require
attention only because of the amount of overcut done by the framer. The method of
repair is as follows:
Use solid pieces of 3/a" PLYWOOD to attach to the side of the LVL beam. A, C,
and D will be repaired on only one side. B will be repaired on both sides. Use
plywood that is the same depth as the beam and 16" wide. CLEANLY cut the
notch required. Use subfloor adhesive and 10d nails @ 2" o.c. at edges and entire
face of plywood to attach plywood to the face of the beam.
Also, in reviewing the stresses on these beams, it was noticed that the beam that crosses
the kitchen is undersized. To correct this:
A 16" LVL [total of (2) 16" LVL] will need attached to both sides of the existing
beam, which is (2) 11-7/8" LVL, The existing beam should already be nailed
together. The new 16" LVL should be nailed to the face of the existing beam
(flush at the top) using 2 rows of 16D nails @ 6" o.c. There shoidd be 1 row 2"
from the top and I row 2" from the bottom of the 11-7/8" beam. The beam
pocket closest to the garage will need expanded to fit the new plies. On the Great
Room end, the new plies will need to be cleanly notched to sit on top of the LVL
beam at the opening of the Great Room. I've drawn a schematic detail of this
beam assembly on the included layout.
~,%pu1rnrrq
ZN CA
Let me know if there are any questions. pR
Steve Blinn ?
ALH Building Systems U
.sue '•AC NE~Q ,a"
U rcGSSP~~~EC 0 4 2000
_.._.._.._.._.._tule°
Illm III
11~
I el`k~
n
Iii NP
mm
r
Illlm mm
o
~III~ III Z m
iil' III FIA
a TO
^III
m s
L z n
m
::Lz
IIII
'iii 111
iii ii
iii
ail
n" IT
7iiN
ii
911
6 _wJia".LVL_.._ ul
it X ~ w
._e-use io:co. @FdM_.._
-jWIVrL
~jl II V' ~II
E M:
IL-.
a~ MV 1le
~iw
n! 1
U 239:61 EVC...........
111
O O III
W
IIl
UI
pf' III
X11
I
r "y
91~
SIII
m
iii ,
,r
i♦ 1
,.a N
F ~t
y:
r 4
» V
4. 1
~ a'~_ ~ _ NP ~f
i
F ~
d I~
s9 a ~ u.~„nY ~ ;,a t ~ ~ ~ ; ~ tk" x i 44n
IW ~ d t 1 ~ jtv" / G Y JY 9' ~ ~y Y df
i ~ H
# it - t ~ d f ~ t ~ ~ ~ ~ ~ s i,..
PF F i I• ~ v E ~ I '9i 4 ~~'k
t^I•!I E ~ „ f' ~ 4 E} ~,rzf~• 0e~~6 i x 5 q~" F
rf' Ir 44 ~ ~ ~ q~f 4
F ~ 1xY I ~1, ~ t~ tf ~{W
r~ i A v j♦~ 5
, N('` ~"d~ 4 4r x'
F s2,r ,,,1! s,~
s ~ i a~ x L ~S x i~~ sr~ ~F~t'` I n~~ 6 t~kpt~ L 3+ ~°5~ f~ {~x
i ~ ~ s" i ~ ~ t: ~h a:}~}y,~i1SY`~#,~~"L"a#~r ~ ~ f t~~j d4 'dC'~~~~ `"p.
r FM ~ ?r ~~~~~f,~V.?~,~y,'~rz ,~,g4^k ~ 41` ~Lip'j~~~~ l~nk ~ n~"2iY~ ?f'~i
t . aa a+41 z{ rc~..F~{3 y F 6t Sq'~ b,:fFr~§~ s ! tt`` -xYix ip~l~~E"ys-PT,!
:9y 3. R }s 5fr~`x* ~r 1~ C.~ s} 1 L h i i 11 Y'a~ u.i..
i h kGF''~ 'C4 J L 1 4'4.r;
~ ~ I . ~ Ott ~ 4 ~ j"~' ~ ~ rk 4 ~ ~ b d t ~ ~^~d
4'0` i ~ ~ i1Sy7p~-r' ypu~3~ x. °wyE{~ q i ' ~...v. ' } 4 t ~ ,ki Yx~`;~. r t. o~
iN 3 K f F 1
• lax ~ ~ ~ h~~ xmV~y ~mx'~ f
ra a qt i k i ~ri n .y 3 i~~Jxb~a rt ~Tja ,c..y'
k F ~~~i~}~ . f td'd~4 a `N~ ~S k. t Y ~ tl~~'~~ q ~1.«~~ y£~I~"~,~.
,.u~as
?
.F{~:~y
.T•V,a""; ,Xv S
s *1'~ RM#'i "s _ *'k't''h 3 {'9 l Jack` ~r
f; S Jw ry !7I ~i b t
~ ~ Ir t
J , , zx m r x yx4 ..w M: r~ , . ~ 37d. ~ F ~ }s'~s
£ s i~ V t ~ ~1" a
, t
;
Y ~ - `~'k'~•C ~ •y ~a`.~, 4 F 1 s, tP.~~'~'~p~'~ p ~'k '7 "~ck
F. 'crv z .#`,!»r, Ja 4 xq.~ rv s a] _-r~ ~3 ;¢'I}Ft" ~z'''.`e
~ ~ IY 1':1~a
Yr'{.~ye'~Fi" F~,ir~,~" 5 €4'Agr~~ ~r~• *r ``r~,wx ~-r,~~Sx~47~i ~P Y"~a~u
x~7 ~a~
t ar r iktf'€~}~'I v ~ 1 wC+sf i r r ~FU
Not
Ir
~`~~ifiiy~a"" }'gym-`-~~ ~JFi~'~,'~'~ ~ ~ r+1~, r ~x" 2 ,~~•F ,F"U a~~`o ~ ~s
j •jS a~yk~"~~.a'~~-`cr;x~xxas u~.~l ~ ~j~ i~Y J~~itx{4'a~ia'S""s`~ ~i t~c i
i PaY f~Y6 fi i} j•Y T 'f4A. y,4'>4 s~ ~i,atlgj ~ Y 'ii t
x sj is'~,x V d€i u s f°.0 T
TI , if~!^` ytsA o- § qyt S" i~tk~~ ;n,1~!~CJ tp t
~'u t' ;N#YF y, ~a f<M nl. d ''y t~ • k
g
. a# ' "f Y5 ~r (G v r r ~ ~,t X `44i ~x.ky 1
..k ma 'L .r" Nt'21 §'~Y t ; 3 t
i ~YA+~~•'i~i2YFrvp~iy s " n,n ~ ;~~~~~~kYI'dl~l.~i~t~~-,. y~t~(Q,~i ~ ~ ro
d{ r~,~ 'i ra}, ~ txr ~ +i ~'~Yt sV , ~r to vy t,`s
ri
t
f q
I
t A ~
k,. 3> t
ay
}p
h E t° ~ ~ a ~ ItM j E.
y~ k
t
y. {
i A 9 ~P*" x
rv. t'
's
s °
t ~ f GG~ A
$ ixi ~ ~ 4 ' (F U{I~: f
$u
ks
t~<
i
4
1
I
rP k~ , . ,
t
kF.
S S
~.I I`` ri ry~~ A • 'S
fary 9+tf
- ~ vk
y 1 ~ uy`
~ a c a1 ~ a ~~y w.
~ ..1 r h v. rtiK 0
5~ ` 3
1 Int~C4 a
IuY' µ
1z _ .u 7 .i E ~ i~
v! 1 t i q
Y k
a ~
i
F -4 d 1 N.
'r((i a ~i ..4 yti ~ ,14 ~t~ r~ie- >.n''-. ~.o k2 rr
mull,
s ue3,1. y5yj 'y a+ u$kl ~ ~l~ ~ru~~~ ~ vE
+ ..En~ea< rt ~ "J"` 'f ~ n a 9vYiz~ 'Cf.
Ji Y A 4 S k ' t+ h .
rvh v~. p ~t
y 1 ~ - ~ F 'c`,d ^I} A nx s ~ ~yg~{,~~~ i~'}va`~~# t ~ 4 Ml~ 5~ z 4 ~~'.f #
1 i~~ x : + ij }v, tH~~~ ~ t~' ~ ~';'P i~#a,>%' Y s'~4~`3 • 1
i z 4 a
r
+d ~ ~I ~4~b o - iT. f v"Y 4 1#f~'r +,.1~`4.y~1^1f
.4- 711t
t n
c`+" ype m'r M t rf
k~ a r ~.g 1 •'tT... a .~L~, INaI'~~.4._ , ~ 4~ ~'x~~ ~t' at.`
MATTHEWS Residence Framing Issues:
The following items are numbered to match the issues presented by Mr. Matthews.
1. A shop drawing is included for the truss 66 that has had its vertical web ripped
to 2" wide. OSB gusset plates will need to be installed to account for metal
truss plates that have been compromised. (See specs on the shop drawing.)
The wall that supports trusses 55-56 should have had a 2"d top plate installed
on site. If the.absence of a 2" d top plate, solid blocking shall be installed
between top plate and each buss, Furthermore, a stud will need to be added in
the wall beneath each roof truss that is not bearing on 2 continuous top plates.
OSB gusset plates will need to be installed to account for metal truss plates
that have been compromised.
2, For general information, the trusses labeled with an `H' are hat trusses that sit
on top of the lower trusses. If the spacing of trusses 60-61 are not as shown
on the truss framing plan, they should be repositioned.
3. The V gap is not out-of-the-ordinary. Install solid blocking between beam
and upright.
4. 1 can't tell what pictures correspond to which LVL beams. Furthermore, I
think that the picture named LVL IN GARG.NOTCHED is actually in the
foyer at the stair. It is very important that any notched LVL be reviewed by
us to make sure that the notches are acceptable, hi order for us to do this, we
need picture of each notched LVL showing the depth of the notch. We need
to be able to locate the exact LVL in the picture so we can figure the loading
on it.
5. Truss 41 is a girder truss that carries trusses 55-60. These trusses are not
carried by a load-bearing wall.
6. See (4) above.
r
G T a im A
d3 °
0
m ~ n.. 9 N l! ^0~1
O N ~ [ON TTT S
CT m N ~ ~ ~ n~ ~
C6 N O
~~$RF-ss7 mgm~~~yo7na~~? ~zI ~N ~ n p~ R
°~~~nNpCOmdg~O~~ 1 3 N
~y2pU~ pmN°'
Ag =z°~}{~gpONO%g~ ~ nmi~ rms, nmS ~ ~ Q
AmQ 2'YZNZ OO iy~ z
a c
zz ~ oz€~
~nfi z
l8~~~~
tom v za~ ~`o5 r• 87.3 -I '
a~C~i Ho-N m•
zp7H~i~~~zH OVpp°va~3 L. 9.8••18 _ _J _ ~
N~~g °z~ p~p m ff _l 3
~ Ny 9.
v D~i yy41~z
60
~~~pNZ~~~a~D
COmy~90~ DNjjym2 0
N N~~~oo8~oa~Il
m
°N Cyy Z~yCO ~
m~~o~~'~mmO4~<oNZ ~
~ @~B~p y 9 y -Ej
I; an un
0 y~ HZN~ ym° to N m C n ro 3 0 Hy th
MEN
P'
Momyp~~%~0 oaa Pzx
CD 0 9.
cc D,
P i7. rn 21 3^Z ~9m~v m
N
C O n n Cl C1 m. O COy
C1 m r- F o
Y f O O O H JG Ny 9 ~q~~ LI
O O 0 0 0
o *0
41
r
PN
O O D m Nm - ~
CD Om m z ° co_ cp
o~ E p
O J
O m
Z N Q N
0 8 8
m
PREPARED 1/16/09, 14:22:41 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 1/20/09
ADDRESS . : 2546 BYRDS MILL RD SUBDIV:
CONTRACTOR : PHONE :
OWNER : MATTHEWS DEMETRIC S & BERDINA PHONE : (910) 980-0552
PARCEL : 12-0576- - -0022- -25-
APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
- - - - -
DIRECTIONS : 157 GREENCREST DRIVE LINDEN 28356.
COWAN SUB DIV SEC II LOT#10. GO DOWN
4015 TOWARDS FYETTEVEILLE, GO THROGH
THE TOWN OF BUNNLEVEL, COME TO
PLANTATION ON THE LEFT, BARE TO THE
LEFT AT THE PLANTATION HOUSE, THAT IS
BYRDS MILL RD, MY LOT IS THE LAST LOT
ACROSS FROM LAST TWO SWMH ON THE LEFT.
T/S: 02/21/2008 08:14 AM VBROWN
PREMISE # 28980232
*JIMMY NEEDS ALL THE ROOF TRUSS PAPERWO
STRUCTURE: 000 000 73X53'6.5. 4BDR 3.5BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . NEW SEPTIC
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/03/08 JH R*BLDG FOOTING / TEMP SVC POLE VRU 001635812
7/03/08 AP no t-pole
A814 01 7/08/08 TI ADDRESS CONFIRMATION VRU 001637750
7/10/08 AP 2546 BYRDS MILL RD LOT 10
B103 01 7/08/08 KS R*BLDG FOUND & TEMP SVC POLE VRU 001637768
7/08/08 AP
E207 01 7/21/08 JH R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001645316
7/21/08 AP
B105 01 7/30/08 TI R*OPEN FLOOR VRU 001651306
7/29/08 CA
B105 02 7/31/08 JH R*OPEN FLOOR TIME: 17:00 VRU 001653104
7/31/08 AP
R427 01 10/20/08 JH FOUR TRADE ROUGH IN >2500 VRU 001693902
10/20/08 CA per Demetric
R427 02 1/09/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001723980
1/08/09 CA
R427 03 1/12/09 TI FOUR TRADE ROUGH IN >2500 VRU 001724491
1/09/09 CA CA PER CUSTOMER CALLING IN
R427 04 1/15/09 DT FOUR TRADE ROUGH IN >2500 VRU 001725704
1/15/09 DA 1. Need to fire block top plate where wall was furred for
plumbing near stairs.
2. Attic access must be moved, catwalk not clear to unit.
3. Trusses 6, 7, 32, 38, and 61 need web braces/strongbacks.
Okay to side and insulate.
1129 01 1/20/09 TpI,QR*INSULATION INSPECTION TIME: 17:00 VRU 001727064
R427 05 / FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001727247
D1 & 1)r
COMMENTS AND NOTES
fREPARED 7/31/09, 14:00:38 INSPECTION TICKET PAGE 4
Harnett County INSPECTOR: IVR DATE 8/03/09
ADDRESS . : 2546 BYRDS MILL RD SUBDIV:
CONTRACTOR.: - PHONE
OWNER i,MATTHEWS DEMETRIC S & BERDINA PHONE (910) 960-0552
PARCEL 12-0576- - -0022- -25-
APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 157 GREENCREST DRIVE LINDEN 28356.
COWAN SUB DIV SEC IT LOT#10. GO DOWN
401S TOWARDS FYETTEVEILLE, GO THROGH
THE TOWN OF BUNNLEVEL, COME TO
PLANTATION ON THE LEFT, BARE TO THE
LEFT AT THE PLANTATION HOUSE, THAT IS
BYRDS MILL RD, MY LOT IS THE LAST LOT
ACROSS FROM LAST TWO SWMH ON THE LEFT.
T/S: 02/21/2008 08:14 AM VBROWN
PREMISE # 28960232
*JIMMY NEEDS ALL THE ROOF TRUSS PAPERWO -
STRUCTURE: 000 000 73X53'6.5" 4BDR 3.5BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/03/08 JH R*BLDG FOOTING / TEMP SVC POLE VRU 001635812
7/03/08 AP no t-pole
A814 01 7/08/08 TI ADDRESS CONFIRMATION VRU 001637750
7/10/08 AP /2546 BYRDS MILL RD LOT 10
B103 01 7/08/08 KS R*BLDG FOUND & TEMP SVC POLE VRU 001637768
7/08/08 AP
E207 01 7/21/08 JH R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001645316
7/21/08 AP
B105 01 7/30/08 TI R*OPEN FLOOR VRU 001651306
7/29/08 CA
B105 02 7/31/08 JH R*OPEN FLOOR TIME: 17:00 VRU 001653104
7/31/08 AP
R427 01 10/20/08 JH FOUR TRADE ROUGH IN >2500 VRU 001693902
10/20/08 CA per Demetric
R427 02 1/09/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001723980
1/08/09 CA
R427 03 1/12/09 TI FOUR TRADE ROUGH IN >2500 VRU 001724491
1/09/09 CA CA PER CUSTOMER CALLING IN
R427 04 1/15/09 DT FOUR TRADE ROUGH IN >2500 VRU 001725704
1115109 DA 1. Need to fire block top plate where wall was furred for
plumbing near stairs.
2. Attic access must be moved, catwalk not clear to unit.
3. Trusses 6, 7, 32, 38, and 61 need web braces/strongbacks.
Okay to side and insulate.
1129 01 1/20/09 DT R*INSULATION INSPECTION TIME: 17:00 VRU 001727064
1/21/09 AP
R427 05 1/20/09 - DT FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001727247
1/21/09 AP
H824 01 2/26/09 OT J ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001739457
2/26/09 AP .
- CONTINUED ONTO NEXT PAGE -
PREPARED 7/31/09, 14:00:38 INSPECTION TICKET PAGE 5
Harnett County INSPECTOR: IVR DATE 8/03/09
- - - - -
ADDRESS . : 2546 BYRDS MILL RD SUBDIV:
CONTRACTOR PHONE
OWNER MATTHEWS DEMETRIC S & BERDINA PHONE (910) 980-0552
PARCEL 12-0576- - -0022- -25-
. APPL NUMBER: 08-50019471 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
R431 01 7/14/09 JH FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001793496
7/14/09 CA T/S: 07/13/2009 10:20 AM NTART
per owner4/2009 12:44 PM JHALL
T/S: 07/15/2009 08:03 AM NTART
R431 02 8/03/09 T_I_ FOUR TRADE FINAL 12500 TIME: S VRU 001803667
T/S: 07/31/2009 12:33 PM DJOHNHNSON ON
COMMENTS AND NOTES -
i ~
t a ((4e Al + w4. "wv! db yt:'~u~t!7 ti_ t
n n., We s (rk, `na. „~'n i0~
COUNTY OF HARNETT
DEPARTMENT OF BUILDING INSPECTION
AND PLANNING/DEVELOPMENT F
CERTIFICATE OF OCCUPANCY"
ti`s This certificate issued pursuantto the requirements of Section 105 of the North Carolina State Building
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in,
compliance with the various ordinances of the County of Harnett regulating development and building
construction or use. For the following:
((lNrr V Use Classification:. 1` - PERMIT NUMBERS
Owner: n ws Building Permit No.:
911 Address: 2- 6 0 Electrical Permit No.:
Insulation Permit No.: \ _ x
!(rr4•rk5` Plumbing Permit No.:
State: A C' Zip Code: Mech. Permit No.: '
- MFG. Home:
Building Official
WW "tl PU"~ .'~~r lUK Li ~lW~ ` tip/ u~'~ : °JN1 ~a~ nMr far ,'vr'h lno "'~Idl ,tw" e °'Nr ~ 1J
1d k,
~