INSPECTIONS
PREPARED 7/30/08, 14:01:32 INSPECTION TICKET PAGE 58
Harnett County INSPECTOR: IVR DATE 7/31/08
ADDRESS . : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
STRUCTURE: 000 000 63X35 3BDR 2BATH SPD
FLOOD ZONE . . . . : FLOOD ZONE X
PERMIT: CPSP 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
8101 01 7/31/08 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
COMMENTS AND NOTES
F(f J t kc LAt} er -moo ln1 e LT
PREPARED 9/02/08, 14:00:30 INSPECTION TICKET PAGE 19
Harnett County INSPECTOR: IVR DATE 9/03/08
ADDRESS . : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
STRUCTURE: 000 000 63X35 3BDR 2BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-
B101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved pending receipt of letter from eng.
A814 01 9/03/08 TI ADDRESS CONFIRMATION VRU 001670959
B103 01 9/03/08 TI R*BLDG FOUND & TEMP SVC POLE VRU 001670967
iyQ" PA~..
- COMMENTS AND NOTES
S~~'~G
8R3- 7575
PREPARED 9/15/08, 14:02:54 '.INSPECTION TICKET PAGE 10
Harnett County 'INSPECTOR: IVR DATE 9/16/08
ADDRESS . : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE : (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE : (919) 258-6094
PARCEL 03-9585-02- -0053-.- -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
STRUCTURE: 000 000 63X35 3BDR 2BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X,
# BEDROOMS . . . . . . . . . ' 3.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . SEWER
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved' pending receipt of letter from eng.
A814 01 9/03/08 TI ADDRESS CONFIRMATION VRU 001670959
9/08/08 AP 496 CAROLINA WAY LOT 53-B
B103 01 9/03/08 MR R*BLDG FOUND & TEMP SVC POLE VRU 001670967
9/03/08 AP
B105 01 9/16/08 TI R*OPEN FLOOR VRU 001677434
COMMENTS AND NOTES
~j
C, rX
PREPARED 11/03/08, 13:59:01 INSPECTION TICKET PAGE 18
Harnett County INSPECTOR: IVR DATE 11/04/08
ADDRESS . : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
STRUCTURE: 000 000 63X35 3BDR 2BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : SEWER
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved pending receipt of letter from eng.
A814 01 9/03/08 TI ADDRESS CONFIRMATION VRU 001670959
9/08/08 AP 496 CAROLINA WAY LOT 53-B
B103 01 9/03/08 MR R*BLDG FOUND & TEMP SVC POLE VRU 001670967
9/03/08 AP
B105 01 9/16/08 MR R*OPEN FLOOR VRU 001677434
9/16/08 DA need waterproofing to foundation before insp.
ok to continue on framing
R425 01 11/04/08 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU 001700806
COMMENTS AND NOTES -
PREPARED 12/10/08, 14:00:36 INSPECTION TICKET PAGE
Harnett County INSPECTOR: IVR DATE 12
' - - - - - -
ADDRESS CAROLINA WAY - -'SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION. INC - PHONE : (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE : (919)._258=6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS :.CAROLINA LAKES SUB DIV'LOT #53. GO TO
CAROLINA'.LAKESr LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM. VBROWN
STRUCTURE: 000 000 63X35 3BDR 2BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE.X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . : SFD
SEPTIC - EXISTING? . . . . : SEWER .
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved pending receipt of letter from eng.
A814 01 9/03/08 TI ADDRESS CONFIRMATION VRU 001670959
9/08/08 AP 496 CAROLINA WAY LOT 53-B
8103 01 9/03/08 MR R*BLDG:FOUND & TEMP SVC POLE VRU 001670967
9/03/08 AP -
B105 01 9116108 MR R*OPEN FLOOR VRU 001677434
9/16/08 DA need waterproofing to foundation before insp.
ok to'continue on framing
R425 01 11/04/08 FOUR TRADE ROUGH IN TIME: 17:00 VRU 001700806
11/04/08 DA 73-77--%o flashing under front door
"2-- no access to area under front door
-'3' ono plans
-4". lot enough room for R-30 insul under AHU platform
eroute wires on floor at AHU platform
6. n support under hip ridge ( need"plans)
-""r finish all tyvek
install roof boots
provide a garage floor line (to check elect panel.)
R425 02 12/11/08 j]TI FOUR TRADE ROUGH IN VRU 001715914
COMMENTS AND NOTES
PREPARED 12/18/08, 14:27:06 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 12/19/08
ADDRESS . : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE : (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE : (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
STRUCTURE: 000 000 63%35 3BDR 2BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : SEWER
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- -
B101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved pending receipt of letter from eng.
A814 01 9/03/08 TI ADDRESS CONFIRMATION VRU 001670959
9/08/08 AP 496 CAROLINA WAY LOT 53-B
B103 01 9/03/08 MR R*BLDG FOUND & TEMP SVC POLE VRU 001670967
9/03/08 AP
B105 01 9/16/08 MR R*OPEN FLOOR VRU 001677434
9/16/08 DA need waterproofing to foundation before insp.
ok to continue on framing
R425 01 11/04/08 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001700806
11/04/08 DA 1. no flashing under front door
2. no access to area under front door
3. no plans
4. not enough room for R-30 insul under AHU platform
5. reroute wires on floor at AHU platform
6. no support under hip ridge ( need plans)
7. finish all tyvek
8. install roof boots
9. provide a garage floor line (to check elect panel.)
R425 02 12/11/08 MR FOUR TRADE ROUGH IN VRU 001715914
12/11/08 DA ok to insulate and side
1. still need supports under valleys per plans
2129 01 12/19/08 TI R*INSULATION INSPECTION VRU 001719420
R425 03 12/19/08 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU 001719707
- COMMENTS AND NOTES -
PREPARED 6/16/09, 14:08:44 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 6/17/09
---'---C 1
- - - -
ADDRESS : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
STRUCTURE: 000 000 63X35 3BDR 2BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : SEWER
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved pending receipt of letter from eng.
A814 01 9/03/08 TI ADDRESS CONFIRMATION VRU 001670959
9/08/08 AP 496 CAROLINA WAY LOT 53-B
B103 01 9/03/08 MR R*BLDG FOUND & TEMP SVC POLE VRU 001670967
9/03/08 AP
B105 01 9/16/08 MR R*OPEN FLOOR VRU 001677434
9/16/08 DA need waterproofing to foundation before insp.
ok to continue on framing
R425 01 11/04/08 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001700806
11/04/08 DA 1. no flashing under front door
2. no access to area under front door
3. no plans
4. not enough room for R-30 insul under AHU platform
5. reroute wires on floor at AHU platform
6. no support under hip ridge ( need plans)
7. finish all tyvek
8. install roof boots
9. provide a garage floor line (to check elect panel.)
R425 02 12/11/08 MR FOUR TRADE ROUGH IN VRU 001715914
12/11/08 DA ok to insulate and side
1. still need supports under valleys per plans
1129 01 12/19/08 MR R*INSULATION INSPECTION VRU 001719420
12/19/08 AP
R425 03 12/19/08 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001719707
12/19/08 AP
R429 01 6/17/09 TI FOUR TRADE FINAL VRU 001782422
E.-)j 9
COMMENTS AND NOTES
HARNETT COUNTY
Building Inspections Dept.
108 E. Front St.
Lillington, NC 27546
910-893-7525
DO NOT REMOVE
DATE: 06-17-09
PERMIT # 08-50020123
ADDRESS: 496 Carolina way
VIOLATIONS:
1. Insulation not complete over front bedrooms
2. Return on air handler is not strapped and sealed properly
3. Dryer vent is to be hard, smooth pipe
4. Finish cross-bracing on rear deck
5. Sub panel is to be on 90 amp max breaker
Fee 50.00
Harnett County Building Department
Mike Rearic cell# (910) 984- 4772
PREPARED"16/25/09, 13:58:20 INSPECTION TICKET PAGE 6
Harnett County INSPECTOR: IVR DATE 6/26/09
- - - -
r'
ADDRESS CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE : (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
STRUCTURE: 000 000 63X35 3BDR 213ATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : SEWER
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved pending receipt of letter from eng.
A814 01 9/03/08 TI DRESS CONFIRMATION VRU 001670959
9/08/08 AP 46 CAROLINA WAY LOT 53-B
B103 01 9/03/08 MR R*BLDG FOUND & TEMP SVC POLE VRU 001670967
9/03/08 AP
B105 01 9116108 MR R*OPEN FLOOR VRU 001677434
9/16/08 DA need waterproofing to foundation before insp.
ok to continue on framing
R425 01 11/04/08 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001700806
11/04/08 DA 1. no flashing under front door
2. no access to area under front door
3. no plans
4. not enough room for R-30 insul under AHU platform
5. reroute wires on floor at AHU platform
6. no support under hip ridge ( need plans)
7. finish all tyvek
8. install roof boots
9. provide a garage floor line (to check elect panel.)
R425 02 12/11/08 MR FOUR TRADE ROUGH IN VRU 001715914
12/11/08 DA ok to insulate and side
1. still need supports under valleys per plans
1129 01 12/19/08 MR R*INSULATION INSPECTION VRU 001719420
12/19/08 AP
R425 03 12/19/08 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001719707
12/19/08 AP
R429 01 6/17/09 MR FOUR TRADE FINAL VRU 001782422
6/17/09 DP 1°. Insulation not complete over front bedrooms
Return on air handler is not strapped and sealed properly
3. Dryer vent is to be hard, smooth pipe
4. Finish cross-bracing on rear deck
5. Sub panel is to be on 90 amp max breaker
T/S: 06/25/2009 10:56 AM NTART
R429 02 6/26/09 TI FOUR TRADE FINAL TIME: 17:00 VRU 001766748
T/S: 06/25/2009 11:04 AM NTART
- - COMMENTS AND NOTES
HARNETT COUNTY
Building Inspections Dept.
108 E. Front St.
Lillington, NC 27546
910-893-7525
DO NOT REMOVE
DATE: 06-26-09
PERMIT # 08-50020123
ADDRESS: 496 carohna way
VIOLATIONS:
1. Pipe on dryer has too many 90's and is to be hard smooth pipe
504.6 Domestic clothes dryer ducts. Exhaust ducts for
domestic clothes dryers shall be constructed of metal and shall
have a smooth interior finish. With the exception of the transition
duct flexible ducts are prohibited The exhaust duct shall
be a minimum nominal size of 4 inches (102 mm) in diameter.
The entire exhaust system shall be supported and secured in
place and shall terminate not less than 12 inches (305 mm)
above finished grade. The male end of the duct at overlapped
duooints shall extend in the direction of airflow. Clothes dryer
transition ducts used to connect the appliance to the exhaust
duct system shall be limited to single lengths not to exceed 8
feet (2438 nun) and shall be listed and labeled for the application.
Transition ducts shall not be concealed within construction
and must remain entirely within the room in which the
appliance is installed.
Exception: Where the duct termination is less than 12
inches (305 mm) above finished grade an areaway shall be
provided with a cross-sectional area not less than 200 square
fat (186m.£.) The bottom of the duct termination shall be
no less than 12 inches (305 mm) above the areaway bottom
504.6.1 Maximum length. The maximum length of a
clothes dryer exhaust duct shall not exceed 45 feet (13 716
nun) from the dryer location to the outlet terminal. The maximum
length of the duct shall be reduced 5 feet (1524 mm)
for each 45 degree (0.79 rad) bend and 10 feet (3048 mm)
for each 90 degree (1.6 rail) bend. The maximum length of
the exhaust duct does not include the transition duct...
2. Install Water heater relief line and it must run to the outside
Harnett County Building Department
Mike Rearic cell# (910) 984- 4772
IYMPARLD1 7/07/09, 14:26:34 INSPECTION TICKET PAGE 11
Harnett County INSPECTOR: IVR DATE 7/08/09
- - - -
ADDRESS . : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAROLINA LAKES SUB DIV LOT #53. GO TO
CAROLINA LAKES, LEFT CAROLINA WAY, LOT
53 IS APPROX 1/2 MI ON RIGHT.
T/S: 05/22/2008 08:10 AM VBROWN
- -
STRUCTURE: 000 000 63X35 3BDR 2BATH SFD
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : SEWER
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 7/31/08 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001652385
7/31/08 AE approved pending receipt of letter from eng.
A814 01 9/03/08 TI ADDRESS CONFIRMATION VRU 001670959
9/08/08 AP 496 CAROLINA WAY LOT 53-B
B103 01 9/03/08 MR R*BLDG FOUND & TEMP SVC POLE VRU 001670967
9/03/08 AP
3105 01 9/16/08 MR R*OPEN FLOOR VRU 001677434
9/16/08 DA need waterproofing to foundation before insp.
ok to continue on framing
R425 01 11/04/08 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001700606
11/04/08 DA 1. no flashing under front door
2. no access to area under front door
3. no plans
4. not enough room for R-30 insul under AHU platform
_5. reroute wires on floor at AHU platform
6. no support under hip ridge ( need plans)
7. finish all tyvek
8. install roof boots
9. provide a garage floor line (to check elect panel.)
R425 02 12/11/08 MR FOUR TRADE ROUGH IN VRU 001715914
12/11/08 DA ok to insulate and side
1. still need supports under valleys per plans
1129 01 12/19/08 MR R*INSULATION INSPECTION VRU 001719420
12/19/08 AP
R425 03 12/19/08 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001719707
12/19/08 AP
R429 01 6/17/09 MR FOUR TRADE FINAL VRU 001782422
6/17/09 DP 1. Insulation not complete over front bedrooms
2. Return on air handler is not strapped and sealed properly
3. Dryer vent is to be hard, smooth pipe
4. Finish cross-bracing on rear deck
5. Sub panel is to be on 90 amp max breaker
T/S: 06/25/2009 10:56 AM NTART
R429 02 6/26/09 MR FOUR TRADE FINAL TIME: 17:00 VRU 001786748
6/26/09 DA T/S: 06/25/2009 11:04 AM NTART
T/S: 06/26/2009 01:43 PM MREARIC
1. Section 504.6 of the mech code prohibits flexible dryer
CONTINUED ONTO NEXT PAGE - - - -
n
P EPARLD.~ 7/07/09, 14:26:34 INSPECTION TICKET PAGE 12
Harnett County INSPECTOR: IVR DATE 7/08/09
ADDRESS . : CAROLINA WAY SUBDIV: CAROLINA LAKES
CONTRACTOR CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 256-6094
OWNER CRAIG TAYLOR CONSTRUCTION INC PHONE (919) 258-6094
PARCEL 03-9585-02- -0053- - -
APPL NUMBER: 08-50020123 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-
ducts you also have 5 -90's in the run
2. water heater relief line needs to be installed and run
to the outside of the foundation
R429 03 7/08/09 TI FOUR TRADE FINAL TIME: 17:00 VRU 001791268
'Z.S_, 6p-M2 T/S: 07/07/2009 12:40 PM VBROWN
COMMENTS AND NOTES -
11n1~' "'.0 ko"i" A01 ~knq
COUNTY OF HARNETT
DEPARTMENT OF BUILDING INSPECTION
k AND PLANNING/DEVELOPMENT
CERTIFICATE OF OCCUPANCY
hkz This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in
compliance with the various ordinances of the County of Harnett regulating development and building
ct construction or use. For the following:
Use Classification: D 3 Conditional Use Permit No.:
Type of Construction: (L Building Permit No.: ~ 8 ~C1 f1 2 C?
Owner of Building: 'r. Electrical Permit No.: r t
Building Address: c Insulation Permit No.:
i
fprNr~, Zoning District: Plumbing Permit No.:
Zoning Permit No.: p Mech. Permit No.:
Date: Envir. C.O.No.:
Building Official Zoning Official ? o
a 4~ • rl i , ..r,'
„r w n P 1 4 N` _ 'N 1 N , ul , 'Ul • '4
y
d l s s )j 1 l _ lM ll~ 11~o b ul 1N° W
i