Loading...
INSPECTIONS PREPARED 4/16/09, 13:58:56 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 4/17/09 ADDRESS . : 56 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR REGENCY HOMES PHONE (910) 424-0455 OWNER REGENCY HOMES INC #532 PHONE (910) 424-0455 PARCEL 01-0514-03- -0006- -31- APPL NUMBER: 08-50020686 CP NEW RESIDENTIAL (SFD) DIRECTIONS : OVERHILLS CREEK SEC #7 LOT #532 TAKE SOUTH MAIN ST/US-401/NC-210, TURN RIGHT ON NC-210 WEST, TURN RIGHT ON BILL SHAW RD, TURN LEFT ON OVERHILLS RD, TURN LEFT ON LENOIR DR, TURN LEFT ON CALDWELL ST, TURN RIGHT ON ROCKINGHAM ST. T/S: 08/07/2008 09:26 AM RDCONTE STRUCTURE: 000 000 57X34.6 CRAWL 3BED W/GAR 6 DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/16/09 Ti R*BLDG FOOTING / TEMP SVC POLE VRU 001755924 4/16/09 CA CUSTOMER CALLED IN AND CAN PUT ON FOR 4-17-09 T/S: 04/16/2009 08:52 AM VBROWN B101 02 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001756402 •17.0 Affl~ - - COMMENTS AND NOTES - PREPARED 4/22/09, 14:00:13 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR DATE 4/23/09 ADDRESS . : 56 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR REGENCY HOMES PHONE (910) 424-0455 OWNER REGENCY HOMES INC #532 PHONE (910) 424-0455 PARCEL 01-0514-03- -0006- -31- APPL NUMBER: 06-50020686 CP NEW RESIDENTIAL (SFD) DIRECTIONS : OVERHILLS CREEK SEC #7 LOT #532 TAKE SOUTH MAIN ST/US-401/NC-210, TURN RIGHT ON NC-210 WEST, TURN RIGHT ON BILL SHAW RD, TURN LEFT ON OVERHILLS RD, TURN LEFT ON LENOIR DR, TURN LEFT ON CALDWELL ST, TURN RIGHT ON ROCKINGHAM ST. T/S: 08/07/2008 09:26 AM RDCONTE STRUCTURE: 000 000 57X34.6 CRAWL 3BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/16/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001755924 4/16/09 CA CUSTOMER CALLED IN AND CAN PUT ON FOR 4-17-09 T/S: 04/16/2009 08:52 AM VBROWN B101 02 4/17/09 BS R*BLDG. FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001756402 4/17/09 AP B103 01 4/23/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001758887 y~-~ Ise bc - - - COMMENTS AND NOTES - - - - PRIPAREIA, 5/15/09, 9:05:10 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 5/15/09 ADDRESS . : 56 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR REGENCY HOMES PHONE (910) 424-0455 OWNER REGENCY HOMES INC #532 PHONE (910) 424-0455 PARCEL 01-0514-03- -0006- -31- APPL NUMBER: 08-50020686 CP NEW RESIDENTIAL (SFD) DIRECTIONS : OVERHILLS CREEK SEC #7 LOT #532 TAKE SOUTH MAIN ST/US-401/NC-210, TURN RIGHT ON NC-210 WEST, TURN RIGHT ON BILL SHAW RD, TURN LEFT ON OVERHILLS RD, TURN LEFT ON LENOIR DR, TURN LEFT ON CALDWELL ST, TURN RIGHT ON ROCKINGHAM ST. T/S: 08/07/2008 09:26 AM RDCONTE STRUCTURE: 000 000 57X34.6 CRAWL 3BED W/GAR & DECK - FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/16/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001755924 4/16/09 CA CUSTOMER CALLED IN AND CAN PUT ON FOR 4-17-09 T/S: 04/16/2009 08:52 AM VBROWN B101 02 4/17/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001756402 4/17/09 AP B103 01 4/23/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001758887 4/23/09 AP A814 01 4/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001758878 4/23/09 AP 56 rockingham st lot 532 BIOS 01 4/29/09 JH R*OPEN FLOOR TIME: 17:00 VRU 001761865 4/29/09 AP R427 01 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001769132 S s --I--~~-'~-----/-/~J--------- COMMENTS AND NOTES :oX F Rdpr~ _ HTE 5N U2009 1209:43 pM6 Application number, type - 0050020686 CP NEW RESIDENTIAL (SFD) Property. address,, 56 ROCKINGHAM ST % _ 1 )Fire caulk holes in top plate to right of door in garage. V ])Replace cut stud on left aide wall of gagare. 3)Mi5sing nails in hangers for floor truss in living room. 4)Mi55ing nails in roof truss hangers above foyer. 5)Smoke detectors in hall upstairs 8 bonus room need to be 3feet from return. i i ) i Egit. Ccel. insert palate Y }Lima stamp deer defaults PREPARED 5/18/09, 14:19:38 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 5/19/09 - - - - - ADDRESS . : 56 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424-0455 OWNER : REGENCY HOMES INC #532 PHONE : (910) 424-0455 PARCEL : 01-0514-03- -0006- -31- APPL NUMBER: 08-50020686 CP NEW RESIDENTIAL (SFD) - - - DIRECTIONS : OVERHILLS CREEK SEC #7 LOT #532 TAKE SOUTH MAIN ST/US-401/NC-210, TURN RIGHT ON NC-210 WEST, TURN RIGHT ON BILL SHAW RD, TURN LEFT ON OVERHILLS RD, TURN LEFT ON LENOIR DR, TURN LEFT ON CALDWELL ST, TURN RIGHT ON ROCKINGHAM ST. T/S: 08/07/2008 09:26 AM RDCONTE STRUCTURE: 000 000 57X34.6 CRAWL 3BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/16/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU 001755924 4/16/09 CA CUSTOMER CALLED IN AND CAN PUT ON FOR 4-17-09 T/S: 04/16/2009 08:52 AM VBROWN B101 02 4/17/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001756402 4/17/09 AP B103 01 4/23/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001758887 4/23/09 AP A814 01 4/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001758678 4/23/09 AP 56 rockingham st lot 532 B105 01 4/29/09 JH R*OPEN FLOOR TIME: 17:00 VRU 001761865 4/29/09 AP R427 02 5/15/09 JH FOUR TRADE ROUGH IN >2500 VRU 001768448 5/15/09 CA on list twice R427 01 5/15/09 FC;JR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001769132 5/15/09 DA 63)Fire caulk holes in top plate to right of door in garage. place cut stud on left side wall of gagare. ~issing nails in hangers for floor truss in living room. -4)FTissing nails in roof truss hangers above foyer. Smoke detectors in hall upstairs & bonus room need to be 3£eet from return. 1129 01 5/1,/0 TI _ R*INSULATION INSPECTION VRU 001768457 R427 03 5S-1 /0T-rFOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001770031 - - - COMMENTS AND NOTES - I IjREPARED 6/24/09, 13:58:14 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 6/25/09 ADDRESS . : 56 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR REGENCY HOMES PHONE (910) 424-0455 OWNER REGENCY HOMES INC #532 PHONE (910) 424-0455 PARCEL 01-0514-03- -0006- -31- APPL NUMBER: 08-50020686 CP NEW RESIDENTIAL (SFD) DIRECTIONS : OVERHILLS CREEK SEC #7 LOT #532 TAKE SOUTH MAIN ST/US-401/NC-210, TURN RIGHT ON NC-210 WEST, TURN RIGHT ON BILL SHAW RD, TURN LEFT ON OVERHILLS RD, TURN LEFT ON LENOIR DR, TURN LEFT ON CALDWELL ST, TURN RIGHT ON ROCKINGHAM ST. T/S: 08/07/2008 09:26 AM RDCONTE STRUCTURE: 000 000 57X34.6 CRAWL 3BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ___R _ B101 01 4/16/09 TI R BLDG FOOTING / TEMP SVC POLE VRU 001755924 4/16/09 CA CUSTOMER CALLED IN AND CAN PUT ON FOR 4-17-09 T/S: 04/16/2009 08:52 AM VBROWN B101 02 4/17/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001756402 4/17/09 AP B103 01 4/23/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001758887 4/23/09 AP A814 01 4/26/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001758878 4/23/09 AP V56 rockingham st lot 532 8105 01 4/29/09 JH R*OPEN FLOOR TIME: 17:00 VRU 001761865 4/29/09 AP R427 02 5/15/09 JH FOUR TRADE ROUGH IN >2500 VRU 001768448 5/15/09 CA on list twice R427 01 5/15/09 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001769132 5/15/09 DA 1)Fire caulk holes in top plate to right of door in garage. 2)Replace cut stud on left side wall of gagare. 3)Missing nails in hangers for floor truss in living room. 4)Missing nails in roof truss hangers above foyer. 5)Smoke detectors in hall upstairs & bonus room need to be 3feet from return. 1129 01 5/19/09 BS R*INSULATION INSPECTION VRU 001768457 5/19/09 AP R427 03 5/19/09 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001770031 5/19/09 AP R431 01 6/25/09 TI FOUR TRADE FINAL >2500 VRU 001786204 6- L-4 ~O iJ COMMENTS AND NOTES _oX . FendbM ~n Iri ,r- -F, - I~ ;ay7 6l25120W 104625AM. Application number, tup,a D8500206MCPNEWRESIDENTIAL(SFDI Property address - 56R MNGHAMST' . 1 Misa ng return rill's 8 filters Upstairs '2)Meetl Z grountl rgotla 8' 8 they need to be 6' apart. the ` ground rods on site were 3' apart a one of them was bent over 5' out of the ground B grade level. 3)Flex duct under house needs to be supported every 4'. F t EjIt tamp I user detault8 C { lnaert palate Limes PREPARED 6/29/09, 13:58:07 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 6/30/09 ADDRESS . : 56 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR REGENCY HOMES PHONE (910) 424-0455 OWNER REGENCY HOMES INC #532 PHONE (910) 424-0455 PARCEL 01-0514-03- -0006- -31- APPL NUMBER: 08-50020686 CP NEW RESIDENTIAL (SFD) DIRECTIONS : OVERHILLS CREEK SEC #7 LOT #532 TAKE SOUTH MAIN ST/US-401/NC-210, TURN RIGHT ON NC-210 WEST, TURN RIGHT ON BILL SHAW RD, TURN LEFT ON OVERHILLS RD, TURN LEFT ON LENOIR DR, TURN LEFT ON CALDWELL ST, TURN RIGHT ON ROCKINGHAM ST. T/S: 08/07/2008 09:26 AM RDCONTE STRUCTURE: 000 000 57X34.6 CRAWL 3BED W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/16/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001755924 4/16/09 CA CUSTOMER CALLED IN AND CAN PUT ON FOR 4-17-09 T/S: 04/16/2009 08:52 AM VBROWN B101 02 4/17/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001756402 4/17/09 AP B103 01 4/23/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001758887 4/23/09 AP A814 01 4/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001758878 4/23/09 AP \/56 rockingham st lot 532 B105 01 4/29/09 JH R*OPEN FLOOR TIME: 17:00 VRU 001761865 4/29/09 AP R427 02 5/15/09 JH FOUR TRADE ROUGH IN >2500 VRU 001768448 5/15/09 CA on list twice R427 01 5/15/09 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001769132 5/15/09 DA 1)Fire caulk holes in top plate to right of door in garage. 2)Replace cut stud on left side wall of gagare. 3)Missing nails in hangers for floor truss in living room. 4)Missing nails in roof truss hangers above foyer. 5)Smoke detectors in hall upstairs & bonus room need to be 3feet from return. 1129 01 5/19/09 BS R*INSULATION INSPECTION VRU 001768457 5/19/09 AP R427 03 5/19/09 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001770031 5/19/09 AP R431 01 6/25/09 FOUR TRADE FINAL >2500 VRU 001786204 6/25/09 DP Missing return grilles & filters upstairs. g)Need 2 ground rods 8' & they need to be 6' apart. the ground rods on site were 3' apart & one of them was bent over 5' out of the ground @ grade level. Tex duct under house needs to be supported every 41. R431 02 6/30/09 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001787068 T/S: 06/25/2009 01:54 PM NTART T/S: 06/26/2009 08:18 AM NTART - CONTINUED ONTO NEXT PAGE PREPARED 6/29/09, 13:58:07 INSPECTION TICKET PAGE 8 'Harnett County INSPECTOR: IVR DATE 6/30/09 ADDRESS . : 56 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR REGENCY HOMES PHONE (910) 424-0455 OWNER REGENCY l HOMES INC #532 PHONE (910) 424-0455 PARCEL 01-0514-03- -0006- -31- APPL NUMBER: 08-50020686 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS T/S: 06/29/2009 09:18 AM NTART COMMENTS AND NOTES r ~ r tip a ((k~ Big ?a ~k ilk ~ ~ ~t~~rAl Bar, ~i, COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION r` AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY ,l This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building y construction or use. For the following: Use Class/ification: ~Zf C/ PERMIT NUMBERS l~ Owner. Ili Building Permit No.: 911 Address:: f Electrical Permit No. ~ Insulation Permit No.: knq Plumbing Permit No.:~O l6~ j State: / / . - . Zip Code: Mech. Permit No.: 1 i , wyh~ Date: - MFG. Home: { Building OHI ial `~1~t 1