Loading...
060-020-P 07.01.10 Revised 07.03.08 If HELD, you must submit 10 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options. Page 3 of 3 Development Review Board LONG RANGE CONDITIONS The following conditions must be satisfied Planning Department: Receive approval from NCDOT for proposed driveway permits, drainage system, and streets Planning Department: Receive approval from NCDENR for erosion control plan Planning Department: Note on the final plat who will be responsible for the maintenance of any drainage and streetscape buffer easements Planning Department: You may proceed with the preparation of the final plat, and the installation of/or arrangement for required improvements in accordance with approved preliminary plat and the requirement of the Harnett County Subdivision Ordinance. In lieu of requiring the completion, installation and dedication of any and all improvements prior to final plat approval, the Planning Department may enter into a written agreement with the subdivider whereby the subdivider shall agree to complete all required improvements. To secure this agreement, the subdivider shall provide, as approved by the Harnett County Planning Department, either one or a combination of Surety Performance Bond, Cash, and Equivalent Security (Letter of Credit). Planning Department: It shall be the responsibility of the developer to formally notify the District Engineer from the N.C. Department of Transportation and initiate the process of transferring the responsibility of road maintenance. If the District Engineer or his designee has not recommended that the N.C. Department of Transportation accept maintenance responsibility for the required public road improvements by the time that the County has issued building permits for seventy-five percent (75%) of the lots shown on the record plat, the County shall not issue any more building permits until the District Engineer makes such a recommendation and formally notifies the Subdivision Administrator. Public Utilities: The proposed utilities must be approved by HCPU and NCDENR. All permits for this project must be obtained from NCDENR and posted on site prior to start of construction. The PE should submit at least three (3) copies of the Utility Plans, Engineer's Report and Project Specifications along with a three party NCDOT Encroachment Agreement to HCDPU for review and subsequent approval.  :  :  :  :  :     Development Review Board Chairman If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you the next business day. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. Page 2 of 3 Development Review Board DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: Meadows at Buies Creek, Phases 8-10 Development Type: Major Subdivision Preliminary Plan/Plat Date: Jan. 10, 2007 (Revised March 8, 2007) The above referenced application is CONDITIONALLY APPROVED as listed below. SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. Fire Mashal: Need to review the construction drawings for hydrant locations Planning Department: Identify correct PIN # 0680-25-5925 Planning Department: Add applicable flood plain information Planning Department: Identify the wetlands if applicable Planning Department: Lot dimensions should be identified Planning Department: Linear feet for streets should be identified Planning Department: Cul-de-sac diameters should be identified Planning Department: Fire hydrant and street light locations should be identified Planning Department: Topography should be identified  :  :  :  :  :  :  :     Page 1 of 3 Development Review Board