Loading...
STAGECREST DECISION PACKET DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: STAGECREST (REVISED) Development Type: Major Subdivision Preliminary Plan/Plat Date: Sep. 12, 2007 The above referenced application is CONDITIONALLY APPROVED as listed below. SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. Fire Marshal (910)893-7580: Fire hydrant to be installed at the intersection of Old Stage Road and Conditionally Approve: Thornton’s Creek Drive Old Stage Road South should be listed as Old Stage Road S  E911/Addressing (910)814-2038: SR1789 should be SR1769  Conditionally Approve: VICINITY MAP: US 421 should be listed as US 421 S Note the total number of proposed lots.  Planning Dept (910)893-7525: 15’ Streetscape buffer along lot#1 at Old Stage Rd.  Conditionally Approve: Update FIRM panel # 372005800J effective October 3,  2006. The Developer must hire a licensed Utility Contractor to  Public Utilities (910)893-7575: install water service taps for each lot. These taps must be Conditionally Approve: made on Harnett County's existing six (6") inch water line in accordance with the current HCDPU Standards and Specifications. The developer shall have a PE submit to HCDPU a set of As  Built Record Drawings indicating the location of the new water service taps and associated meter boxes. The developer must pay HCDPU the capacity fees ($700.00  per lot) for these new taps before any meters may be set on any lot. An alternative would be that the developer could pay HCDPU  $1,525.00 per lot for the taps to be installed by HCDPU and the above items would not be required. The As Built Record Drawings on file for Thornton's Creek  Subdivision and the associated six (6") inch water line does not show a fire hydrant at the intersection of Old Stage Road and Thornton's Creek Drive. The Harnett County Fire Marshal will require an additional fire hydrant to be installed at this intersection. The fire hydrant must be installed by a licensed utility contractor in accordance with the current HCDPU Standards and Specifications. Environmental Health (910)893-7547: Approve: STAGECREST DECISION PACKET 3/30/2009 1 LONG RANGE CONDITIONS The following conditions must be satisfied Public Utilities (910)893-7575: Must meet all requirements set forth by NC DENR. For more information, please call (910)433-3300 The developer and the utility contractor must provide HCDPU with a one (1) Public Utilities (910)893-7575: year warranty on the water service taps and fire hydrant that will be installed to serve the 6 residential lots in the Stagecrest subdivision if the taps and fire hydrant are not installed by HCDPU. : : : : Development Review Board Chairman If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2) business days. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait, as all DRB members will have to review the plat/plan for compliance. If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Friday following the meeting the application was put on hold. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options. STAGECREST DECISION PACKET 3/30/2009 2