Loading...
IPACHTE#08-s Z11-l~ Harnett County Department of Public Health 2 51 2 5 Imarovement Permit A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: /,SS-Z l .a 02.E 104 ISSUED TO• 7A/,ot H?iyimp a SUBDIVISION LOT # 3 NEW REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: MO Proposed Wastewater System Type: Z5% f2-1f ~J CITt,GQwYTr~~ Projected Daily Flow: Z#Sa GPD Number of bedrooms: Number of Occupants: max Basement ❑Yes No 0- May Required: ❑Yes ❑ No 0MMay required based on final location and elevations of facilities Type of Water Supply: ❑ Community fd' Public ❑ Well Distance from well feet Permit valid for. 0 -Five years Permit conditions: ❑ No expiration Authorized State Agent • Date: 3 - 5- - O 1 SEE ATTACHED SITE SKETCH The issuance of this permit by t Ith Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met Systems shall be installed in accordance with the attached system layout ISSUED TO: 50--- /ham (,,s,~ PROPERTY LOCATION: Sit /S3Z f G~ -t - SUBDIVISION LOT # Facility Type: / 2' New ❑/Expansion ❑ Repair Basement? 1:1 Yes No Basement Fixtures? El Yes 1~ No Type of Wastewater System" Zn iZF.-b tJU'?40 ~„sttis t~~ Ord ~ (Initial) Wastewater Flow: '6196 GPD (See note below, if applicable 2570/0 i~ (Repair) Installation Requirements/Conditions Number of renches -Z- Septic Tank Size /Zoo gallons Exact length of each trench t -i' S feet Trench Spacing: f Feet on Center Pump Tank Size gallons Trenches shall be installed on contour at a Soil Cover: inches Maximum Trench Depth of: 18"O-r4-)e inches (Maximum soil cover shall not exceed (Trench bottoms shall be level to +/-1/4" 36" above the trench bottom) in all directions) Pump Requirements: ft. TDH vs. GPM inches below pipe If Aggregate Depth: Z inches above pipe Conditions: rn+x lyr-h Pe-P -1H ! /L inches total *`If applicable: /understand the system type specified is different from the type specified on the application. / accept the speci&ations of this permit. Owner/Legal Representative Signature: Date: - v„-.,- -J- - 11 lilt lilt pion, pidt, ur me mrenueu use cnanges. ine construcuon Authorization shall not be transferred when there is a change in ownership of the site. This Construction Authorization is subject to compliance with the provisions of the taws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH Authorized State Agen Date: 3 - S - a 9 Construction Authorization Expiration Date: 3 - I y HTE# D$ - S - Z t 1-7 Permit # 5" I a Harnett County Department of Miblic Health Site Sketch PROPERTY LOCATON: 3►t I W Z IL6 ISSUED TO: h/~) m, SUBDIVISION LOT Authorized State Agent: .q-,~ Date: d S a v'f- . Slb~t A 7~ s t~-4' ZZ1 ~r 3b ~T F_ ,z 15-572- A6 41D ~t, ~ 1~ vcNaiu~ic It f u~•..v.uuw , ..v Division of Environmental Health On-site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Address: Proposed Facility: Location of Site: Water Supply: Evaluation Method: Type of Wastewater. Property 1D: Lot File Code: Applicant: 2 6!'7-1~' Date Evaluated: q-crp l, ' t Design Flow (.1949): ~f Property Size: Property Recorded: [.1'Public [ J Individual [Well Spring (J Other ( f Auger Boring [ j Pit [ J Cut [ j-cyewage (J Industrial Process (J Mixed P R o F SOIL MORPHOLOGY .1941 OTHER " . PROFILE FACTORS, 1 L E # 1940 Landscape Position/ Slope% Horizon Depth (IN.) .1941 Structure/ Texture 1941 Consistence Mineralogy .1942 Soil Wetness/ Color .1943 Soil Depth (IN.) .1956 Sapro Class .1944 Restr Hariz ProfJle r, Class;;; & LTAR 1 Lei'/ , Z s° > r ~ S • Z T' Z L y~,~ e cc x.C 30 ~ te L r S . si. d y Description Initial Systevy" Repair stem Available Space (.1945) System Type(s) ZSr3L Z Site LTAR ~ - . Other Factors (.1946): Site Classification (.1948): Evaluated By: Others Present: