IPACHTE# -7 -ZeCZ Harnett County Department of Public Health Improvement Permit 26806 A building permit cannot be issued with only an Improvement Permit P ~ PROPERTY LOCATION:,-,`5/~ %/S OV 2Z ISSUED T0: Lt So SUBDIVISION LOT # L_ NEW Pl' REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: 5r,-) Proposed Wastewater System Type: Z5% /02- 2y Projected Daily Flow: '3& GPD Number of bedrooms: - 3 Number of Occupants: Amax Basement ❑Yes 1216 Pump Required: ❑Yes ❑ No LrJ'Mae required based on final location and elevations of facilities Type of Water Supply: ❑ Community E, Public ❑ Well Distance from well feet Permit conditions: Permit valid for I=!J"Five years ❑ No expiration Authorized State Ag t:: Date: (Z-15 f SEE ATTACHED SITE SKETCH The issuance of this permit b t Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: PROPERTY LOCATION:/ % e / SUBDIVISION LOT # / Facility Type: Z New ❑ Expansion ❑ Repair Basement? ❑ Yes No Basement Fixtures? ❑ Yes f"No Type of Wastewater System** 'T % (Initial) Wastewater flow: :3&6 GPD (See note below, if applicable iln r bi- 'l l (Repair) Installation Requirements/Conditions Number of trenches Septic Tank Size D0- gallons Exact length of each trench /:576 feet Pump Tank Size gallons Trenches shall be installed on contour at a Pump Requirements: ft. TDH vs. Conditions: Maximum Trench Depth of: ZC inches (Trench bottoms shall be level to +/-1/4" in all directions) GPM WATER LINES (INCLUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. O UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. **If applicable: / understand the system type specified is different from the type specified on the app/ication. / accept the specifications of this permit. Owner/Legal Representative Signature: Date: This Construction Authorization is subiect to revocation if the site plan, olat, or the intended use chances. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State ent: Date: / Z Construction Authorization Expiration Date: / Trench Spacing: / Feet on Center Soil Cover: inches (Maximum soil cover shall not exceed 36" above the trench bottom) inches below pipe Aggregate Depth: Z inches above pipe / Z inches total HTE # Permit # Gam' & Harnett County Department of Public Health Site Sketch PROPERTY LOCATON: Llr`5'~7i,I S C!f iI~ ISSUED TO: o,-, SUBDIVISION LOT # f Authorized State ent: Date: :a Z - a 1>110 .5 ~ Sr7i l Department of Environment, Health and Natural Resources Division of Environmental Health On-Site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Applicant: Address: Date Evaluated: t2l~-ii Proposed Facility: f Design Flow (.1949): 361-4 Location of Site: !52 i y, sue' Property Recorded: ' Water Supply: [-Public❑ Individual ❑ Well Evaluation Method:[5 tAugerBoring ❑ Pit ❑ Cut Type of Wastewater: EI-Sewage ❑ Industrial Process Sheet: Property ID: Lot File Code: Property Size: ❑ Spring ❑ Mixed ❑ Other P R O F I 1940 SOIL MORPHOLOGY OTHER L Landscape Horizon .1941 PROFILE FACTORS E # Position/ Slope % Depth .1941 (In.) Structure/ .1941 Consistence .1942 Soil Wetness/ 1943 .1956 S il .1944 Profile Texture Mmeralo Color o Sapro D th IN. Class Restr Class Horiz & LTAR ~ rJ~ !t lfjgr! L AL 6 3631-1Z 32- V -3 Z, Description Initial Repair System Other Factors (.1946): Available Space .1945) S ste Site Classification (.1948 S stem T e(s) Evaluated B Others Present q Site LTAR y _k , , Thomas J. Boyce P.O. Box 81 Pittsboro, NC 27312 NC Licensed Soil Scientist # 1241 NC Registered Sanitarian # 1353 Benton W. Dewar and Associates 5920 Honeycutt Road Holly Springs, NC 27540 Re: Proposed two acre lot, Wes Matthews - owner, Rawls Chuch Rd. Dear Mr. Shackle, A soils evaluation was completed on the above referenced property on November 20, 2011. The purpose of the evaluation was to determine the ability of the soils to support a subsurface waste disposal system and repair area. All ratings and determinations were made in accordance with "Laws and Rules for Sewage Treatment and Disposal Systems, 15A NCAC 18A.1900" . The tract was evaluated by auger borings and landscape position. The typical usable soils were a sandy loam over clay to thirty or more inches. The long term acceptance rate will probably be .3 gpd/sgft. Soils were limited by shallow depth to saprolite. A soils map has been provided showing the approximate areas evaluated. The lot appears to contain sufficient area for initial and repair for a four bedroom house (60X60). Systems may be conventional, accepted, alternative, or innovative. Systems may also require the use of a pump, fill, or additional cover. This report does not guarantee or represent approval or issuance as needed by the local health department. This report only represents my opinion as a licensed soil scientist. I trust this is the information that you require at this time. If you have any questions, please call. Sincerely, Thomas J. Boyce w W cW,~ z H B k~ O a. 0- 7 N gg E-- O o Q TjU~o pptl3Q '°a'8 Z S uWj SON 1~ ~Lg UWn~ I y 0 0 0 0 o> w= amgaHC~7 x S''~s I 00 0 0 y g N FWF?z ~ azW ~ ~ 3~pgp «°g~S ggu Ygdg pY f OZ ~ ~ mN 7z O m W l l k-4E €S E$ o r~ m °W fi o WEOi~z," 33b q~°K I m a ohs + o N x o o ~x ° n .~a 3mo gil so of a W rNd a ° ;a z~~ =ga_ gg g E~ g NI~ W p~ = W ° omw OtWs.°b sbSgOCO P$ $ F-t Wzwox$$~5 F I 5 = g m0.~nxag~~~b I E$y w d a ¢ o a~ Q W kj-11 rt ~ 'srr ¢W¢ N ~ ~ ~ •a5~ 6 S9/Bt/Zt 0U3N017i °wl ~.IQ O <o Z ~N O ¢ $ z . 0 0 8~ ~Q OK UW V Z~O R4 00 N OJ% W OZ W Nai MR ~ e W + I I W o ' 00 11I 00 ~ N ~ N I i N ~4 1 uo,Y z ~ I ti~u 6 a 0 U al ~ V x m U a a I U ~ I ~z m NON p°~ k Nnm i b Y ~S h ^ }Z Y LL'MOyO u°•i ,RJR g:.4-W Wb mmyd 3° z og~ l V S 03'59'03"E w ~ S-~ o O • O a.. ro wW 400.00 N 03'59'0 _ _ 719. m N mNm oJ~ vi~ O Naywj9 I OCi M va~l N W ^oa ~ao~ O m Sr I P -I V ~ ~ ?tflm~ O g .7{i o in 3a N (Y US 401 N "ai d v° O ~y 0 HEC10P'S CREEK v ~a k2 0, fS41 tlS Z ORS111 °1101OS3l~u d U _Z s{YI as - J m I a x I I Ike' 1 4 I ~ W 0 0 it ~ n N N N Of Z IN o~ N I ~Fp ~ Yo z <o of I ~ ao InW 3 S~ ~ ~~u~~`~~ a 3 g ` 8 ° ~qx E I~ ~ ~xo ~ttyy . M I