HomeMy WebLinkAboutPhalanx_revised site plan set_1.17.23SITE DETAILC6.0
CONCRETE PIPE CONCRETE PIPE
"A" "A"
SECTION "A"-"A"
2.00'2.00'DIA. VARIESGEOTEXTILE
NON-WOVEN FABRIC
W/ 1' MIN. OVERLAP
PIPE JOINT
TOUNGE &
GROOVE
JOINTS
MASTIC SEAL
SCALE: N.T.S.
PIPE JOINT
4"
12"12"
NOTES:
1. MIN. 6" #57 STONE BEDDING SHALL BE REQUIRED IF TRENCH
BOTTOM IS BELOW THE GROUND WATER TABLE.
2. FILL SHALL BE NATIVE MATERIAL FREE OF LARGE ROCKS,
DEBRIS OR ORGANICS PLACED IN 6" LIFTS AND COMPACTED
TO 95% OF THE SOIL'S MODIFIED PROCTOR.
FINISHED GRADE
NATIVE BEDDING
MATERIAL. SEE
NOTES BELOW.
FILL MATERIAL
SLOPE TRENCH PER
OSHA REQUIREMENTS
SCALE: N.T.S.
REINFORCED CONCRETE PIPE BEDDING
NOT TO SCALE
NCDOT FRAME AND GRATE DETAIL
NOT TO SCALE
NCDOT JUNCTION BOX DETAIL
NOT TO SCALE
NCDOT - DROP INLET - TYPE 'A'
TOP VIEW
SECTION A-A
A A
6'-1 3/4"
24"
30"
36"
6'-1"
8'-2"
DIMENSIONS
DIA.
15"
18"
L
6'-1"
6'-1"
L
PIPEDIA.DIA.SCALE: N.T.S.
FLARED END SECTION
NOTE: CONTRACTOR CAN USE 840.17 IN LIEU OF 840.26 NOTE: CONTRACTOR CAN USE 840.19 IN LIEU OF 840.28
NOT TO SCALE
NCDOT - DROP INLET - TYPE 'B'
6" DIA. STEEL SLEEVE
ENCASED IN CONCRETE
6" STEEL CASE BOLLARD
FILLED WITH CONCRETE
36"
ABOVE FINISH
GRADE ELEV.
18" MIN.
ASPHALT, SEE
PAVEMENT SECTION
AND MOUNDED ON TOP
PAINTED YELLOW
COMPACTED GABC,
SEE PAVEMENT SECTION
FINISH GRADE ELEVATION
TO MATCH BOTH SURFACES
6" - 4' x 4' CONCRETE PAD
(3000psi MIN.)
SCALE: N.T.S.
CONCRETE BOLLARD
SLOPE AS SHOWN ON PLAN
2" MINIMUM NCDOT 403
TYPE B ASPHALT
6" MIN. COMPACTED STABILIZED
AGGREGATE BASE COURSE (G.A.B.C.)
COMPACTED TO 98% OF THE
SOILS MODIFIED PROCTOR MAXIMUM
DRY DENSITY (ASTM D 1557)
EXISTING
SUBGRADE
SCALE: N.T.S.
24" PREPARED SUBGRADE PLACED IN
LIFTS NOT EXCEEDING 8 INCHES IN
COMPACTED THICKNESS AND DENSIFIED
IN-PLACE TO 98% OF THE SOILS STANDARD
PROCTOR MAXIMUM DRY DENSITY
(ASTM D 698)
TYPICAL ASPHALT SECTION
5'
18"
12"
12"
6"
WHERE
APPLICABLE FINISH GRADE
NOTE:
HANDICAP SIGN TO CONFORM WITH THE "MANUAL ON
UNIFORM TRAFFIC CONTROL DEVICES" LATEST EDITION
LOCATION: HANDICAPPED PARKING SIGNS SHALL BE
LOCATED 4 FT MIN. OFF OF BACK OF CURB ON CENTER
WITH THE WHEEL STOP.
SCALE: N.T.S.
HANDICAP PARKING SIGN (R7-8 8a)
Know what's belowCall before you dig.
Dial 811
Or Call 800-632-4949
1
2
3
4 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY:
DRAWN BY:
APPROVED BY:
SHEET:
CIVIL
NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH
-
JEHPHALANX CROSS FETCAMERON, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSLOPE AS SHOWN ON PLAN
6" MIN. COMPACTED STABILIZED
AGGREGATE BASE COURSE (G.A.B.C.)
COMPACTED TO 98% OF THE
SOILS MODIFIED PROCTOR MAXIMUM
DRY DENSITY (ASTM D 1557)
EXISTING
SUBGRADE
SCALE: N.T.S.
24" PREPARED SUBGRADE PLACED IN
LIFTS NOT EXCEEDING 8 INCHES IN
COMPACTED THICKNESS AND DENSIFIED
IN-PLACE TO 98% OF THE SOILS STANDARD
PROCTOR MAXIMUM DRY DENSITY
(ASTM D 698)
TYPICAL GRAVEL SECTION
NC 87 (PUBLIC R/W)
EX. 10" PVC WATER MAIN
EX. 2" WATER MAIN
EX. 16" PVC SEWER FORCE MAIN (Not In Operation)
W W W W W W W W
FM FM FM FM FM FM FM FM
W W W W W W W W
OE OE OE OE OE OE OE
PROPOSED 80'X150'
BUILDING
12,000 SF
150'80'
3
7
3
378
378
379
380
381
381
381
387386385384
383382382382
381
379
378
377
376
374
372
371385390 380
375
370
373372
373
371370369
367366367366366370364369
368
365366
365
3703843823803793833853873893873903
8
4391390391392 390389391392386387385383382381381BF368
371
368
366.50
372
374375
371
370 369
368
15.0' TYPE A & D
BUFFER AT
SIDES
15.0' TYPE A & D
BUFFER AT FRONT
15.0' TYPE A & D
BUFFER AT SIDES
15.0' TYPE A& D
BUFFER AT REAR
PROPOSED
DRAINAGE DITCH
PROPOSED
DRAINAGE DITCH
PROPOSED
DRAINAGE DITCH
50 PLANTS / 200 SF
OF VEGETATIVE SHELF:
VEGETATIVE SHELF: 1,060 SF ,
265 PLANTS REQUIRED
ANY EXISTING TREES/SHRUB ON THE
PROPERTY WHICH ARE NOT IN AN AREA
BEING GRADED SHALL REMAIN AND
CAN SUPPLEMENT THE PROPOSE
LANDSCAPE BUFFER.
ANY EXISTING TREES/SHRUB ON THE
PROPERTY WHICH ARE NOT IN AN AREA
BEING GRADED SHALL REMAIN AND
CAN SUPPLEMENT THE PROPOSE
LANDSCAPE BUFFER.LANDSCAPE PLAN AND DETAILL 1.0
NOTE:
1. CONTRACTOR TO REGRADE, SOD OR HYDROSEED, AND STRAW MULCH ALL AREAS DISTURBED AS ARESULT OF HIS/HER WORK.
2. UPRIGHT STAKES TO BE USED ON TREES UP TO 12' IN HEIGHT. LARGER TREES MUST BE GUYED.
3. 1/8 OF ROOT BALL TO BE ABOVE FINISHED GRADE.
4. DO NOT COVER CROWN OF ROOT BALL EVERGREEN TREES WHICH ARE TIGHTLY SPACED SHALL BE
TIED TOGETHER IN ONE CONTINUOUS BED. (CONTRACTOR TO INCLUDE THIS MULCHING IN HIS/HER BID)
5. TREES WHICH ARE LOCATED WITHIN 4 FEET OF AN ADJACENT SHRUB BED SHALL HAVE THEIRMULCHED AREA CONNECTED WITH THE MULCHED BED OF THE SHRUBS.
6. PRUNE AND REMOVE BROKEN OR DEAD LIMBS/BRANCHES FROM TREES AND SHRUBS AFTERPLANTING. RETAIN NATURAL SHAPE OF PLANT.
NOTE:
1. BEDS TO HAVE SMOOTHLY CONTOURED AND CLEANLY DEFINED EDGES. BEDS SHALL CURVILINEAR EXCEPT AS NOTED ON PLAN.
2. PROPOSED BEDS MUST BE LAID OUT ON SITE AND APPROVED BY OWNER, IF REQUESTED BY OWNER.
3. REMOVE TOP 1/3 OF ALL BURLAP FABRIC AROUND ROOT BALL.
4. COMPLETELY REMOVE ALL STRINGS, RIBBONS, AND TABS FROM THE PLANT.
5. SCARIFY ROOTS ON POT BOUND PLANTS.
6. PLANT SPACING VARIES - (SEE PLAN)
7. ALL SHRUBS TO BE PLANTED IN MULCHED BEDS.
8. PRUNE ALL BROKEN, DISEASED, AND WEAK BRANCHES.
9. ALL SHRUB BEDS TO BE COMPLETELY EXCAVATED OF ALL EXISTING SOIL TO REQUIRED DEPTH AND BACKFILLED WITH REQUIRED SOIL
MIX.
10. SOIL MIX: 2/3 TOPSOIL & 1/3 ORGANIC MATTER.
11. TOP DRESS BED WITH 10-6-4 FERTILIZER AT THE RATE OF 5 LBS. PER 100 S.F. OF BED AREA.
GENERAL NOTES:
1.1 THIS PLAN IS FOR LANDSCAPE PURPOSES ONLY. LANDSCAPE PLAN PROVIDED IS FOR MINIMUM COMPLIANCE WITH HARNETT COUTY UDO AND SHOULD
NOT BE CONSIDERED AN ENHANCED LANDSCAPE PLAN. CONSULT WITH A REGISTERED LANDSCAPE ARCHITECT FOR SPECIFIC PLANTING RECOMMENDATIONS.
1.2 UNDERGROUND UTILITIES HAVE NOT BEEN VERIFIED BY THE OWNER, LANDSCAPE ARCHITECT, OR THEIR REPRESENTATIVES. PLEASE CALL BEFORE YOU
DIG.
1.3 THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE RESPONSIBLE
FOR ANY AND ALL DAMAGES WHICH MIGHT RESULT FROM THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY UNDERGROUND UTILITIES
TO REMAIN.
1.4 THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO ENSURE THAT THE NEW WORK SHALL FIT INTO THE EXISTING SITE IN THE MANNER INTENDED
AND AS SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY
THE OWNER'S REPRESENTATIVE PRIOR TO PERFORMING ANY WORK IN THE AREA INVOLVING DISCREPANCIES. NOTIFICATION SHALL BE MADE IN THE FORM OF
A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATING TO THE AREA.
1.5 ALL WORK SHALL MEET OR EXCEED THE REQUIREMENTS OF ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES AND REQUIREMENTS.
1.6 IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PERFORM ALL WORK IN A MANNER THAT PROTECTS COMPLETED WORK BY OTHERS, SUCH AS CURBS,
UTILITIES, STORM DRAINAGE, FENCES, DRIVEWAY APRONS, DRIVES, VEGETATION, ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF
SATISFACTORY REPAIR OF ALL DAMAGES IN KIND RESULTING FROM HIS/HER FAILURE TO COMPLY.
1.7 THE CONTRACTOR IS TO VERIFY ALL QUANTITIES SHOWN ON THE PLAN AND IN THE PLANT SCHEDULE. IF DISCREPANCIES OCCUR, THE CONTRACTOR
SHALL CONTACT THE LANDSCAPE ARCHITECT IMMEDIATELY. QUANTITIES OF PLANTS SHOWN BY LANDSCAPE SYMBOLS SHALL GOVERN OVER THE QUANTITIES
SHOWN IN THE PLANT SCHEDULE.
1.8 ALL MATERIALS SHALL BE SUBJECT TO APPROVAL BY THE LANDSCAPE ARCHITECT. THE OWNER SHALL RECEIVE TAGS FROM EACH PLANT SPECIES AND A
LIST OF PLANT SUPPLIERS. WHERE ANY REQUIREMENTS ARE OMITTED FROM THE PLANT LIST, THE PLANTS FURNISHED SHALL MEET THE NORMAL
REQUIREMENTS FOR THE VARIETY OR CULTIVAR PER THE AMERICAN STANDARD FOR NURSERY STOCK, LATEST EDITION, PUBLISHED BY THE AMERICAN
ASSOCIATION OF NURSERYMEN (AAN). PLANTS SHALL BE PRUNED PRIOR TO DELIVERY ONLY UPON THE APPROVAL OF THE LANDSCAPE ARCHITECT.
1.9 NO SUBSTITUTIONS OF PRODUCTS, PLANT TYPES OR SIZES SHALL BE MADE WITHOUT WRITTEN APPROVAL OF THE OWNER, LANDSCAPE ARCHITECT, AND
MUNICIPAL REVIEW AGENCY. REQUESTS FOR SUBSTITUTION SHALL BE IN WRITING, AND SHALL STATE THE REASONS FOR THE SUBSTITUTION REQUEST, THE
SUGGESTED ALTERNATIVE, AND THE CHANGES IN COST. REQUESTS FOR SUBSTITUTION IN PLANT MATERIAL SHALL STATE THE NAMES OF NURSERIES WHO
HAVE BEEN UNABLE TO SUPPLY THE ORIGINALLY SPECIFIED MATERIAL.
1.10PLANTING SHALL ONLY OCCUR DURING SPECIFIED PLANTING SEASONS. SPRING SEASON SHALL BE FROM MARCH 1 TO JUNE 15. FALL PLANTING SEASON
SHALL BE FRO SEPTEMBER 15 TO NOVEMBER 15.
1.11 THE CONTRACTOR SHALL GUARANTEE ALL LANDSCAPE IMPROVEMENTS, INCLUDING SEEDING, FOR ONE FULL YEAR AS REQUIRED BY THE SPECIFICATIONS.
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL PLANT MAINTENANCE DURING THE GUARANTEE PERIOD.
1.12INSTALLED UNIT PRICES FOR ALL PLANT MATERIAL SHALL BE SUPPLIED TO THE OWNER AND LANDSCAPE ARCHITECT AT THE TIME OF BIDDING.
1.13 THE LANDSCAPE CONTRACTOR IS TO PERFORM A THOROUGH CLEANUP AND QUALITY CONTROL INSPECTION WITHIN 12 HOURS PRIOR TO THE OPENING
OF THE POOL.
1.14 THE LANDSCAPE CONTRACTOR IS SUBJECT TO RANDOM INSPECTIONS BY THE OWNER AND/OR THE OWNER'S REPRESENTATIVE AT ANY TIME DURING THE
INSTALLATION PROCESS.
TREE/SHRUB PLANT LIST:BOTANICAL NAME: SIZE: COUNT:SYMBOL:
RED MAPLE ACER RUBRUM 2" CAL., 6' HT. 41
PRIVET LIGUSTRUM JAPONICUM 3 GAL.210
ALL TREES SHALL BE AT LEAST TWO (2) INCHES IN CALIPER AND A MINIMUM OF SIX (6) FEET IN HEIGHT
AT THE TIME OF PLANTING.
KEEP MULCH AWAY
FROM TRUNK
MULCH, MIN.
DEPTH OF 4"
3" MIN. - 6" MAX.TOP OF BALL
FINISHED GRADE
BOTTOM OF BALL
BOTTOM OF PIT
6" MIN
ROOTBALL, AS
NOTED
UNDISTURBED NATIVE
SOIL PEDESTAL
2.5 X BALL DIA.
(MIN.)
6" MIN. HIGH NATIVE
SOIL SAUCER
NATIVE SOIL
BACKFILL
12" MIN
FINISHED GRADE
SET SHRUB PLUMB
SHRUB PLANTING
SCALE: N.T.S.
PLANT BED:
NATIVE SOIL BACKFILL,
DEPTH AS NOTED
FINISHED GRADE AND
TOP OF PLANT BED
EQUAL
"X" MIN 2/3 "X" MIN
MULCH, DEPTH AS
NOTED
INCREASE DEPTH OF MULCH
AS DETAILED, AT EDGE OF
ALL PLANTING BEDS.
FINISHED GRADE OF
LAWN OR WALK
'X' AS
NOTED
PLANT BED EDGING DETAIL
SCALE: N.T.S.
KEEP MULCH AWAY
FROM TRUNK
MULCH, MIN.
DEPTH OF 4"
3" MIN. - 6" MAX.TOP OF BALL
FINISHED
GRADE
BOTTOM OF BALL
BOTTOM OF PIT
6" MIN
ROOTBALL, AS
NOTED
UNDISTURBED NATIVE
SOIL PEDESTAL
2.5 X BALL DIA.
(MIN.)
6" MIN. HIGH NATIVE
SOIL SAUCER
NATIVE SOIL
BACKFILL
WOOD OR METAL
STAKES
12" MIN
FINISHED
GRADE
RUBBER HOSES
GUY WIRES, WITH
TURNBUCKLES
SET TREE PLUMB
SHADE AND UNDERSTORY
TREE PLANTING
SCALE: N.T.S.
4
Know what's belowCall before you dig.
Dial 811
Or Call 800-632-4949
1
2
3
4 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY:
DRAWN BY:
APPROVED BY:
SHEET:
CIVIL
NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH
-
JEHPHALANX CROSS FETCAMERON, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONNORTH0'
SCALE IN FEET
15 30 60