Loading...
HomeMy WebLinkAboutCedar Pointe Plan set 10.27.22-rev-RFSSTANDARD MAINTENANCE NOTE: SIDEWALKS AND STREET TREE ARE TO BE MAINTAINED BY THE HOME OWNERS ASSOCIATION ("HOA"), PROPERTY OWNERS ASSOCIATION ("POA"), CONDOMINIUM OWNERS ASSOCIATION ("COA"), OR ANY OTHER ASSOCIATION RESPONSIBLE FOR THE MAINTENANCE AND/OR UPKEEP OF THE RESIDENTIAL COMMUNITY. SIDEWALK OR STREET TREE INSTALLATIONS THAT ARE DAMAGED AND/OR REMOVED BY HARNETT COUNTY/DEPARTMENT OF PUBLIC UTILITIES/HARNETT REGIONAL WATER OR ITS REPRESENTATIVE AGENTS, OR CONTRACTORS AS A RESULT OF REPAIR/MAINTENANCE OF THE PUBLIC WATER AND/OR SEWER LINE WILL BE REPLACED OR REPAIRED BY THE HOME OWNERS ASSOCIATION ("HOA"), PROPERTY OWNERS ASSOCIATION ("POA''), CONDOMINIUM OWNERS ASSOCIATION ("COA"), OR ANY OTHER ASSOCIATION RESPONSIBLE FOR THE MAINTENANCE AND/OR UPKEEP OF THE RESIDENTIAL COMMUNITY. GENERAL NOTES: (REFERENCE SHEET C4.5 FOR HRW WATER AND SEWER STANDARD NOTES.) 1.ALL WORK SHALL COMPLY WITH HARNETT COUNTY AND NCDOT STANDARDS AND SPECIFICATIONS. 2.THIS PROJECT IS SERVED BY PUBLIC WATER AND PUBLIC SEWER OWNED, MAINTAINED ANDOPERATED BY HARNETT REGIONAL WATER. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES AND REPAIRING ANYDAMAGE TO SAME. UTILITY LOCATIONS AS SHOWN ON PLANS ARE APPROXIMATE AND MAY NOT BECOMPLETE. THE CONTRACTOR SHALL HAVE NORTH CAROLINA ONE CALL (1-800-632-4949) LOCATEALL EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. 4.PROVISIONS SHALL BE MADE TO ENSURE POSITIVE DRAINAGE ON THE SITE AT ALL TIMES. NATURALDRAINAGE FEATURES DISTURBED BY CONSTRUCTION MUST BE RE-ESTABLISHED. NO PONDING DUETO SPOILS STOCKPILING OR OTHER ACTIVITIES SHALL BE PERMITTED. 5.WORK IN PUBLIC RIGHT-OF-WAYS OR PRIVATE EASEMENTS SHALL BE ACCOMPLISHED BY THECONTRACTOR ACCORDING TO THE REQUIREMENTS OR CONDITIONS OF THE ENCROACHMENT PERMITOR OTHER LEGAL DOCUMENTS AS THOUGH DOCUMENTS WERE ISSUED IN THE CONTRACTOR NAME.THE CONTRACTOR SHALL MAINTAIN COPIES OF THESE DOCUMENTS ON THE SITES AT ALL TIMES. 6.WHEN THE CONTRACTOR IS UNABLE TO COMPLETE HIS WORK AS SHOWN ON THE PLANS BECAUSEOF AN EXISTING UTILITY, CONTRACTOR SHALL STAKE THE LOCATION OF THE UTILITY PRIOR TOPROCEEDING AND CONTACT THE ENGINEER. 7.THE CONTRACTOR SHALL NOTIFY ALL PUBLIC AGENCIES, THE OWNER, THE ENGINEER AND ALL OTHERCONCERNED PARTIES WHEN CONSTRUCTION IS TO COMMENCE. PRIOR TO ANY CONSTRUCTION APRECONSTRUCTION MEETING SHALL BE HELD WITH THE MUNICIPALITY/ AUTHORITY, THECONTRACTOR, THE ENGINEER AND ANY OTHER INTERESTED PARTY. 8.DATA REQUIRED FOR PREPARATION OF RECORD DRAWINGS SHALL BE OBTAINED BY THECONTRACTOR AT THE TIME FOR INSTALLATION. DATA SHALL BE ACCUMULATED BY THE CONTRACTORDURING THE CONSTRUCTION PERIOD AND PROVIDED TO THE ENGINEER UPON COMPLETION OF THEPROJECT 9.INSPECTIONS SHALL BE CONDUCTED IN ACCORDANCE WITH ALL APPLICABLE HARNETT COUNTY,NCDNER AND NCDOT STANDARDS. 10.ALL EXCAVATED EXCESS OR WASTE SOILS AND MATERIAL SHALL BE REMOVED FROM THE SITE BYCONTRACTOR EXCEPT AS SPECIFICALLY APPROVED IN WRITING BY BOTH THE ENGINEER AND OWNER. 11.WHEN CONCRETE SIDEWALKS, CURB AND GUTTER SECTIONS OR ASPHALT PAVEMENT ARE DAMAGEDDUE TO CONSTRUCTION ACTIVITIES, THEY SHALL BE REPLACED IN A TIMELY MANNER BY THECONTRACTOR TO ASSURE THE CONTINUED USE OF THESE FACILITIES BY ALL CONCERNED. 12.CONTRACTOR IS TO COMPLY WITH ALL PROVISIONS OF THE MANUAL OF UNIFORM TRAFFICCONTROL DEVICES WHEN WORKING ADJACENT TO AN EXISTING PUBLIC HIGHWAY RIGHT OF WAY. 13.THE CONTRACTOR WILL MAINTAIN ALL EXISTING ROADS IN A NEAT AND CLEAN CONDITIONTHROUGHOUT THE COURSE OF THE PROJECT CONSTRUCTION. WATER/SEWER CAPACITY NOTE: APPROVAL OF THE PLAT/PLAN DOES NOT GUARANTEE WATER OR SEWER TREATMENT CAPACITY. CURRENT/FUTURE CAPACITY MAY NOT BE AVAILABLE. THIS DEVELOPMENT MAY REQUIRE ADDITIONAL IMPROVEMENTS TO THE EXISTING WATER SYSTEM OR SEWER SYSTEM TO MEET FUTURE WATER AND SEWER DEMANDS PRIOR TO A PRELIMINARY PLAY, CONSTRUCTION PLAN AND/OR FINAL PLAT APPROVAL. OW SIGNATURE OA�pW tL PROJECT NUMBER: SU B2209-0023 22 CEDAR POINTE RESIDENTIAL DEVELOPMENT JOHNSONVILLE, NORTH CAROLINA ------------------------------- 13 12 11 10 14 '8 7 6 ,:--,J..._�I j ,'1/,_ -:....--/1 20 19 18 ----------- 23 "25 16 15 17 ---------------- -------------"30 31 32 33 34 35 26 27 -------- OVERALL PLAN DEVELOPER/OWN ER CEDAR POINT, LLC 350 WAGONER DRIVE FAYETTEVILLE, NC 28303 PHONE: 919-606-4696 EMAIL: cbd1971@gmail.com 36 5 4 ----- 37 3B 39 ::::--_ -----r''---------:.._-..::-_-_::- ' ' ' -' -·-----._ 0 HORZ. I 100 200 SCALE FEET 24 SITE @ VICINITY MAP NOTTO SCALE SHEET SCHEDULE SHEET TITLE SHEET NO: ORIGINAL DATE LATEST REVISION DATE COVER SHEET 01 SEPTEMBER 15, 2022 - EXISTING CONDITIONS Cl.O SEPTEMBER 15, 2022 - SITE PLAN C 2.0 SEPTEMBER 15, 2022 - EROSION CONTROL PLAN -INITIAL PHASE C 3.0 SEPTEMBER 15, 2022 - EROSION CONTROL PLAN -CONSTRUCTION PHASE C 3.1 SEPTEMBER 15, 2022 - EROSION CONTROL PLAN -FINAL PHASE C 3.2 SEPTEMBER 15, 2022 - EROSION CONTROL GROUND STABILIZATION AND SELF C 3.3 SEPTEMBER 15, 2022 INSPECTION NOTE - EROSION CONTROL NOTE C 3.4 SEPTEMBER 15, 2022 - EROSION CONTROL DETAIL C 3.5 SEPTEMBER 15, 2022 - EROSION CONTROL DETAIL C 3.6 SEPTEMBER 15, 2022 - EROSION CONTROL DETAIL C 3.7 SEPTEMBER 15, 2022 - WATER LINE PLAN AND PROFILE C4.0 SEPTEMBER 15, 2022 - WATER LINE PLAN AND PROFILE C4.1 SEPTEMBER 15, 2022 - WATERMAIN DETAIL C4.2 SEPTEMBER 15, 2022 WATERMAIN DETAIL C4.3 SEPTEMBER 15, 2022 UTILITY NOTES C4.4 SEPTEMBER 15, 2022 ROADWAY PLAN AND PROFILE C 5.0 SEPTEMBER 15, 2022 - ROADWAY PLAN AND PROFILE C 5.1 SEPTEMBER 15, 2022 - ROADWAY CROSS SECTION C 5.2 SEPTEMBER 15, 2022 - ROADWAY CROSS SECTION C 5.3 SEPTEMBER 15, 2022 - ROADWAY CROSS SECTION C5.4 SEPTEMBER 15, 2022 - ROADWAY CROSS SECTION C 5.5 SEPTEMBER 15, 2022 - ROADWAY CROSS SECTION C 5.6 SEPTEMBER 15, 2022 - ROADWAY CROSS SECTION C 5.7 SEPTEMBER 15, 2022 - ROADWAY CROSS SECTION C 5.8 SEPTEMBER 15, 2022 - WATER AND SITE DETAILS C 7.0 SEPTEMBER 15, 2022 - STORMWATER MANAGEMENT DETAIL C 8.0 SEPTEMBER 15, 2022 - LANDSCAPING PLAN C9.0 OCTOBER 24, 2022 REVISION OCCURRENCE LIST REVISION NO. DATE REVISION DESCRIPTION BY THIS SET IS CURRENT THROUGH SHEET DATED: SEPTEMBER 15, 2022 ENGINEERING� PLLC 3417 Winterwind Circle, Sanford, NC 27330 PO Box 249, Sanford, NC 27331 Phone: (919) 352-2834 e-mail: jhilliard@hilliardengineering.com NC License #: P-0836 TIE N 79°41'20" W 57.20' 208.31'S 82°19'50" E S 30°56'18" W 65.84'S 07°04'54" W 207.84'EXISTING AXLE 31.60'L1L2L3L4139.20'238.64' 3 2 D 1 335.78' D 5 6 1 31 1 S 78°13'33" E 1032.19' 78.59' 128.17' 200.95' 144.15'N 20°03'58" W 80.29'5 4 1 N 07°24 '59 " W 44.86 'N 19 °13 '59 " W 169 .84 ' A B N 07°24'59" W 60.24' C N 71° 3 6' 4 9" E 6 4 9 . 8 6' S 86°20'11" E 8 8 7 . 6 4 ' T O T A L S 79°41'20" E 380.74'S 79°41'20" E 192.22' S 78°02'59" E 218.26' N 78°02'59" W 262.17'S 33°33'43" W 274.43'N 76°34'13" W 409.44' TOTAL N 78°09'28" W 849.44'S 17°44'15" W 259.41' TOTALN 78°12'14" W 884.55'1/2" S OLI D IR O N 1/2" SOLID IR ON 1/2" SOLID IR ON 1/2" S OLID I R ON CONTROL CO R N E R EXISTING IRO N P O S T NC GRID CO O R D I N A T E S NORTH:541 , 7 0 4 . 4 5 ' EAST: 1,972 , 6 8 1 . 7 4 ' NAD 83 (20 1 1 )1/2" SOLID IR O N EXISTING 1" I R O N P I P E 0 . 7 ' BELOW SUR A C E A T F L U S H WOOD POST 6 5 4 3 2 1 A B C D 2" S OLI D IR O N EXISTING 1" I R O N PIPE DISTUR B E D A T FLUSH WOO D POST EXISTING CO N C R E T E MONUMNET EXISTING CO N C R E T E MONUMNET 1/ 2 " S O L I D I R O N 344345347348 349346 3503433393403413423383343303263223283293313323333303343233153163173193203213243253273143223263183 2 3 3193203213 2 4 3 2 5 3 2 7 32 8 329 331 33 2 33 3 3223 2 6 330 33 4 31833 6 33 7 338335336337338 339 340 3 41 342 339 340 341 342 338 3 4 3 3 4 4 3 4 5 3 4 7 348 3493 4 6 3503 4 1 3 4 2 34 0343 344 34534734834934635034 7 34 8 349 350 3 4 3 3 3 7 339 3403 41 3 4 4 3 4 5 3 4 2 338331 332 333 335 3 3 6 334323320321324325327328329331332333335336337 339340341342338322326330334HMS KI D S I N C DEED B O O K 4 0 9 3, P A G E 9 6 9574- 0 2- 4 0 6 3 SHERI T. HARDISON, ET AL DEED BOOK 4164, PAGE 348 PLAT BOOK 2003, PAGE 559 PIN: 9574-21-6448 SHERI T. HARDISON, ET AL DEED BOOK 4164, PAGE 348 PLAT BOOK 2003, PAGE 559 PIN: 9574-21-2577 SHERI T. HARDISON, ET AL DEED BOOK 4164, PAGE 348 PLAT BOOK 2003, PAGE 559 9574-21-0623PIEDRA JORGE LUIS & GARC IA VERONICADEED BOOK 3423, PAGE 4399574-11-8773CLARK ANGIE RENEE JT W/ROS & CLARK MICHAEL L JR JT W/ROSDEED BOOK 3427, PAGE 9709574-11-7773HERNANDEZ ARMANDO GARCIA & CARBAJAL CATALINA OLASCOAGADEED BOOK 3779, PAGE 7599574-11-6764FRIEND ANDREA JOSETTEDEED BOOK 3251, PAGE 6289574-11-5754JARAMILLO-RUVALCABE JOSE DEJESUSDEED BOOK 3927, PAGE 00019574-11-4735RUSSELL SKYLER MASONDEED BOOK 3864, PAGE 8139574-11-2785LABBE S A MA NT HA DEED B O O K 4 1 3 0, P A G E 1 0 3 957 4- 1 1- 1 7 3 9 JANSEN JEREMIAH D & JANSEN MICHELLE A DEED BOOK 3241, PAGE 605 9574-10-6982 HMS KIDS IN C DEED BOOK 4 0 9 3 , P A G E 9 6 9564-80-48 3 9 SMITH ELI EVERETT DEED BOOK 4111, PAGE 182 9574-10-2850 EQUITY CAPITAL UNITED, LLC DEED BOOK 2871, PAGE 709 PLAT CABINET F, SLIDE 320-D PIN: 9574-20-1859.000 EQUITY C APITAL U NITE D, LL C DEED B O O K 2 8 5 1, P A GE 4 1 5 PLAT C A BI NE T F, SLI DE 3 2 0- D PIN: 9 5 7 4- 2 0- 3 8 4 5. 0 0 0 ZONINGZONING: RA-20R PROPERTY ID NUMBERSPIN: 9574-11-5237.000PIN: 9574-01-7133.000 DEED BOOK & PAGE: 4164 / 0.375 4158 / 1268 TOTAL EXISTING TRACT = 26.40 AC WETLANDS: NO WETLAND EXIST ON THIS SITE PER INVESTIGATION REPORT BY HAL OWENS & ASSOCIATES, INC DATED SEPTEMBER 6, 2022 COORDINATES: LATITUDE: 35.2368LONGITUGE: -79.0920 RECEIVING WATERBODY: BUFFALO CREEKFROM SOURCE TO LITTLE RIVER WATERBODY INDEX: 18-23-18WATERSHED:CAPE FEAR LAND USE: AGRICULTURAL DISTRICT(S): MILITARY CORRIDOR OVERLAY EXISTING CONDITIONC1.0Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONFEETSCALE 0 80 160 HORZ. EX. OVERHEAD POWER EX. 6" WATERMAIN PROPOSED ACCESS EASEMENT & GRAVEL SURFACE PROPOSED ACCESS EASEMENT & GRAVEL SURFACE EXISTING UTILITY EASEMENT EX. GRAVEL ROAD PROPOSED ACCESS EASEMENT & GRAVEL SURFACENORTHVICINITY MAP NOT TO SCALE 8 7 24 MARKS ROADCAMERONHILL ROADGILCH RIS T ROAD W R O A D RIPLEY R D SITE DASHED BOUNDARY LINES LINES NOT SURVEYED; INFORMATION OBTAINED BY DEEDS AND/OR PLATS OF RECORD AS NOTED NCGS/USGS GRID TIE NO CONTROL MONUMENTS RECOVERED WITHIN 2,000 FEET OF SITE WATERLINE LOCATION PER COUNTY GIS ALL AREAS CALCULATED BY COORDINATE METHOD UNLESS OTHER WISED NOTED GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH ALL HARNETT COUNTY AND NCDOT STANDARDS. 2. CONTRACTOR IS TO VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ENGINEER. 3. A PORTION OF THE PROPERTY SHOWN HEREON IS LOCATED IN A SPECIAL FLOOD HAZARD AREA, ZONED AE , BASED FLOOD ELEVATION, 158.9', AS DETERMINED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY. FLOOD HAZARD: ZONE X (REMAINDER OF PROPERTY) MAP: 3720052400K ~ PANEL: 0524 EFFECTIVE: 5 JANUARY 2007 4. CONTRACTOR SHALL LOCATE AND VERIFY DEPTHS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO BEGINNING CONSTRUCTION. 5. CONTRACTOR IS REQUIRED TO MEET ALL APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS AND ASSUMES FULL RESPONSIBILITY FOR COMPLIANCE. 6. ALL DEBRIS FROM DEMOLITION OPERATIONS SHALL BE DISPOSED OF OFF SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. 7. ALL EXISTING PAVEMENT EDGES SHALL BE SAW CUT TO A STRAIGHT EDGE. 8. UTILITIES TO REMAIN IN PLACE SHALL BE PROTECTED FROM DAMAGE. CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES. 9. CONTRACTOR SHALL COORDINATE ALL DEMOLITION OPERATIONS WITH GOVERNING AGENCIES AND UTILITY COMPANIES. SURVEY NOTES: BOUNDARY SURVEY AND EXISTING FEATURES PROVIDED BY : ATLAS SURVEYING & MAPPING 1503 OLD CARBONTON ROAD SANFORD, NORTH CAROLINA. STEVEN W. MULLINS, PLS NC. LICENSE NO. 4740 C B A 4 3 2 1 D 6 5 EXISTING POSSIBLE AND APPARENT OVERLAPS AND GAPS GAP CREATED BETWEEN DEED BOOK 681, PAGE 488 AND DEED BOOK 786, PAGE 887 (MAP) OVERLAP CREATED BETWEEN DEED BOOK 681, PAGE 488 AND DEED BOOK 1077, PAGE 955 GAP CREATED BETWEEN DEED BOOK 786, PAGE 885 AND DEED BOOK 1077, PAGE 955 OVERLAP CREATED BETWEEN DEED BOOK 786, PAGE 885; DEED BOOK 4164, PAGE 375 PLAT CABINET F, SLIDE 301-B AND DEED BOOK 1077, PAGE 955 EXISTING BOUNDARY LINE AND CLAIMED PROPERTY LINE CONDITIONS PROPERTY LINE CRATED IN ERROR DEED BOOK 1077, PAGE 955 PROPERTY LINE CREATED IN ERROR DEED BOOK 697, PAGE 810 SEE: PLAT CABINET F, SLIDE 301-B BOUNDARY LINE DEED BOOK 4164, PAGE 375 DEED BOOK 786, PAGE 885 PLAT CABINET F, SLIDE 301-B BOUNDARY LINE DEED BOOK 681, PAGE 488 PROPERTY LINE CREATED IN ERROR DEED BOOK 786, PAGE 885 BOUNDARY LINE CORRECTED PER INTENT MARKS ROAD - NCSR 111160' PUBLIC RIGHT-OF-WAY (PAVED)EX. 6" WATER MAIN 3443453473483493463503433393403413423383343303263223283293313323333303343233153163173193203213243253273143223263183233193203213243253273 2 8 32 9 33 1 33 2 3 3 3 32232633 0 3 3 4 3183 3 6 3 3 7 338335336337338 33934034134 2 339 340 341 342 338 3433443453473483493463503 4 1 3 4 2 3 4 0 3433443453473483493463503 4 7 3 4 8 34 9 350 3 4 3 33 7 3393403413 4 4 3 4 5342 338331 332 33 3 33 5 33 6 33 4 332333335336337339340341342338334HMS KID S I N C DEED BO O K 4 0 9 3 , P A G E 9 6 9574-02 - 4 0 6 3 SHERI T. H A R D I S O N , E T A L DEED BOO K 4 1 6 4 , P A G E 3 4 8 PLAT BOO K 2 0 0 3 , P A G E 5 5 9 PIN: 9574 - 2 1 - 6 4 4 8 SHERI T. H A R D I S O N , E T A L DEED BO O K 4 1 6 4 , P A G E 3 4 8 PLAT BOO K 2 0 0 3 , P A G E 5 5 9 PIN: 9574- 2 1 - 2 5 7 7 SHERI T. H A R D I S O N , E T A L DEED BOO K 4 1 6 4 , P A G E 3 4 8 PLAT BOO K 2 0 0 3 , P A G E 5 5 9 9574-21- 0 6 2 3PIEDRA JORGE LUIS & GARCIA VERONICADEED BOOK 3423, PAGE 4399574-11-8773CLARK ANGIE RENEE JT W/ROS & CLARK MICHAEL L JR JT W/ROSDEED BOOK 3427, PAGE 9709574-11-7773HERNANDEZ ARMANDO GARCIA & CARBAJAL CATALINA OLASCOAGADEED BOOK 3779, PAGE 7599574-11-6764FRIEND ANDREA JOSETTEDEED BOOK 3251, PAGE 6289574-11-5754JARAMILLO-RUVALCABEJOSE DEJESUSDEED BOOK 3927, PAGE00019574-11-4735RUSSELL SKYLER MASONDEED BOOK 3864, PAGE 8139574-11-2785LABB E S A M A N T H A DEED B O O K 4 1 3 0, P A G E 1 0 3 9574- 1 1 - 1 7 3 9 JANSEN JE R E M I A H D & J A N S E N M I C H E L L E A DEED BOO K 3 2 4 1 , P A G E 6 0 5 9574-10-6 9 8 2 HMS KIDS INC DEED BOOK 4093, PAGE 96 9564-80-4839 SMITH E L I E V E R E T T DEED BO O K 4 1 1 1 , P A G E 1 8 2 9574-1 0 - 2 8 5 0 EQUITY C A P I T A L U N I T E D , L L C DEED B O O K 2 8 7 1 , P A G E 7 0 9 PLAT CA B I N E T F , S L I D E 3 2 0 - D PIN: 95 7 4 - 2 0 - 1 8 5 9 . 0 0 0 EQUIT Y C A PI T A L U NI T E D, L L C DEED B O O K 2 8 5 1, P A G E 4 1 5 PLAT C A BI N E T F, S LI D E 3 2 0- D PIN: 9 5 7 4 - 2 0- 3 8 4 5 . 0 0 0 CE TEMPORARY STOCKPILE AREA WITH SILT FENCE. MAINTAIN MINIMUM 50' FROM SEDIMENT DEVICESSFO SFO SFO SFO SFO SFO CL CL CL CL CL CL CL CL CL CL CL CL CL CL BF LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE SF SF SF SF SF SF SF SF BEGIN SILT FENCE BEGIN SILT FENCE PD TEMPORARY DIVERSION DITCH (TYP.) TD TEMPORARY DIVERSION DITCH (TYP.)RIP RAP OUTLET APRON 01 APRON WIDTH AT SWALE OUTLET: 15' APRON LENGTH: 104' APRON WIDTH AT BOTTOM OF POND: 38' APRON THICKNESS: 2.25' THICK CLASS 1 RIP RAP ON MIRIFI FILTER FABRIC. EMBED RIP RAP 2.25' INTO GROUND SO THAT RUNOFF FLOWS ON TOP OF THE RIP RAP SURFACE. RIP RAP OUTLET APRON 02 APRON WIDTH AT SWALE OUTLET: 8' APRON LENGTH: 52' APRON WIDTH AT BOTTOM OF POND: 19' APRON THICKNESS: 1.5' THICK CLASS B RIP RAP ON MIRIFI FILTER FABRIC. EMBED RIP RAP 1.5' INTO GROUND SO THAT RUNOFF FLOWS ON TOP OF THE RIP RAP SURFACE. RIP RAP OUTLET APRON 03 APRON WIDTH AT PIPE OUTLET: 4' APRON LENGTH: 24' APRON WIDTH AT SILT FENCE OUTLET: 18' APRON THICKNESS: 1.5' THICK CLASS B RIP RAP ON MIRIFI FILTER FABRIC. EMBED RIP RAP 1.5' INTO GROUND SO THAT RUNOFF FLOWS ON TOP OF THE RIP RAP SURFACE. SEDIMENT BASIN 01 SEDIMENT BASIN WITH BAFFLES BOTTOM LENGTH: 222' BOTTOM WIDTH: 102' TOP OF DAM ELEV: 321.50 BOTTOM OF BASIN ELEV: 317.00 SEDIMENT CLEANOUT ELEV: 318.00 BASIN SIDE SLOPES: 3:1 FROM ELEV 317.00 TO ELEV 321.50 (BASIN) 5:1 FROM ELEV 321.50 TO ELEV 330.00 (CUT SLOPE) 5:1 FROM ELEV 321.50 TO 314.00 (FILL SLOPE) SKIMMER DEVICE FOR SEDIMENT BASIN: 4" SKIMMER WITH 4" ORIFICE 2'-2" X 3' PRECAST CONCRETE RISER RISER WEIR ELEVATION 318.50' SKIMMER CONNECTION TO RISER ELEVATION: 317.00' 48 LF OF 15" O-RING RCP OUTLET PIPE WITH CUTOFF TRENCH AND ANTI-SEEPAGE COLLARS AS SHOWN SEE SEDIMENT BASIN AND POND DETAILS FOR ADDITIONAL INFORMATION EXISTING GRAVEL ROAD PROPERTY BOUNDARY EXISTING GRAVEL ROAD PERMANENT DIVERSION SWALE WITH BERM 01A BOTTOM WIDTH 4.0' MIN. DEPTH: 1.0' BERM HEIGHT: 0.56' TOTAL DEPTH FROM TOP OF BERM TO BOTTOM OF DITCH: 1.5' TOP OF BERM WIDTH: 2.0' BOTTOM OF BERM WIDTH: 6.0' SIDE SLOPE: 3:1 LINING: SEED AND MULCH WITH CONTRACTOR'S BLEND AND NAG S75 MATTING OR EQUIVALENT PERMANENT DIVERSION SWALE WITH BERM 01B BOTTOM WIDTH: 7.0' MIN. DEPTH: 1.0' BERM HEIGHT: 0.50' TOTAL DEPTH FROM TOP OF BERM TO BOTTOM OF DITCH: 1.5' TOP OF BERM WIDTH: 2.0' BOTTOM OF BERM WIDTH: 6.0' SIDE SLOPE: 3:1 LINING: SEED AND MULCH WITH CONTRACTOR'S BLEND AND EXCELSIOR MATTING OR EQUIVALENT. PERMANENT DIVERSION SWALE WITH BERM 03 BOTTOM WIDTH 3.0' MIN. DEPTH: 1.0' BERM HEIGHT: 0.58' TOTAL DEPTH FROM TOP OF BERM TO BOTTOM OF DITCH: 1.5' TOP OF BERM WIDTH: 2.0' BOTTOM OF BERM WIDTH: 6.0' SIDE SLOPE: 3:1 LINING: SEED AND MULCH WITH CONTRACTOR'S BLEND AND NAG S75 MATTING OR EQUIVALENT POROUS COIR FIBER BAFFLES (TYP) PD PD PD EROSION CONTROL PLAN -INITIAL PHASEC3.0 GENERAL NOTES: PURSUANT TO G.S. 133-A57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION-CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 7 OR 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PERMANENT GROUNDCOVER WILL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORE THAN 90 CALENDER DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUNDCOVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 CALENDAR DAYS OR 60 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. ANY BORROW MATERIAL BROUGHT ONTO THIS SITE MUST BE FROM A LEGALLY PERMITTED MINE SITE OR OTHER APPROVED SOURCE. A SINGLE-USE BORROW OR WASTE AREA SITE IS ONLY PERMISSIBLE IF IT IS OPERATED UNDER CONTROL OF THE FINANCIALLY RESPONSIBLE PERSON OR FIRM THAT IS DEVELOPING THIS SITE. AN APPROVED EROSION AND SEDIMENT CONTROL PLAN IS REQUIRED FOR ALL SINGLE USE BORROW AND WASTE SITES. EROSION CONTROL DESIGN, DETAILS AND MAINTENANCE SPECIFICATIONS SHALL COMPLY WITH CURRENT NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. SELF INSPECTION NOTE: THE LANDOWNER, THE FINANCIALLY RESPONSIBLE PARTY, OR THE LANDOWNER'S OR THE FINANCIALLY RESPONSIBLE PARTY'S AGENT SHALL PERFORM AN INSPECTION OF THE AREA COVERED BY THE PLAN AFTER EACH PHASE OF THE PLAN HAS BEEN COMPLETED AND AFTER ESTABLISHMENT OF TEMPORARY GROUND COVER IN ACCORDANCE WITH G.S. 113A-57(2). THE PERSON WHO PERFORMS THE INSPECTION SHALL MAINTAIN AND MAKE AVAILABLE A RECORD OF THE INSPECTION AT THE SITE OF THE LAND-DISTURBING ACTIVITY. THE RECORD SHALL SET OUT ANY SIGNIFICANT DEVIATION FROM THE APPROVED EROSION CONTROL PLAN, IDENTIFY ANY MEASURES THAT MAY BE REQUIRED TO CORRECT THE DEVIATION, AND DOCUMENT THE COMPLETION OF THOSE MEASURES. THE RECORD SHALL BE MAINTAINED UNTIL PERMANENT GROUND COVER HAS BEEN ESTABLISHED AS REQUIRED BY THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN. THE INSPECTIONS REQUIRED BY THIS SUBSECTION SHALL BE IN ADDITION TO INSPECTIONS REQUIRE BY G.S. 113A-61.1. SEE NCGO1 INSPECTION, RECORDKEEPING AND REPORTING PLAN SHEET. DESCRIPTIONPRACTICESYMBOL SILT FENCE A TEMPORARY STRUCTURE USED TO SLOW THE VELOCITY OF RUN-OFF,CAUSE SEDIMENT DEPOSITION AT THE STRUCTURE, AND FILTER SEDIMENT FROM RUN-OFF.SF CONSTRUCTION LIMITS A DEFINED AREA THAT ALL LAND DISTURBANCE WILL OCCUR DURING CONSTRUCTION.CL CONSTRUCTION ENTRANCE A STONE STABILIZED PAD LOCATED AT ANY POINT THAT TRAFFIC WILL BELEAVING A CONSTRUCTION SITE TO A PUBLIC RIGHT-OF-WAY, STREET, ALLEY, SIDEWALK, OR PARKING PLOT WHICH WILL REDUCE OR ELIMINATETHE TRANSPORT OF MUD FROM THE CONSTRUCTION SITE. CE PROTECTION A TEMPORARY STRUCTURE AS A REINFORCED OUTLET AT LOW POINTS OF THE SILT FENCE. INSTALL #57 WASHED STONE AT UPSTREAM FLOW WITHHARDWARE CLOTH. (SEE DETAIL)SFO SILT FENCE OUTLET DIVERSION A TEMPORARY RIDGE OR EXCAVATED CHANNEL OR COMBINATION RIDGEAND CHANNEL CONSTRUCTED ACROSS SLOPING LAND ON APREDETERMINED GRADE.PD PERMANENT SB AN EARTHEN EMBANKMENT SUITABLY LOCATED TO CAPTURE RUNOFF,WITH A TRAPEZOIDAL SPILLWAY LINED WITH AN IMPERABLE GEOTEXTILEOR LAMINATED PLASTIC MEMBRANE, AND EQUIPPED WITH A FLOATING SKIMMER FOR DEWATERING. SEDIMENT BASIN BF POROUS BARRIERS INSTALLED INSIDE A TEMPORARY SEDIMENT TRAP,SKIMMER BASIN, OR SEDIMENT BASIN TO REDUCE THE VELOCITY AND TURBULENCE OF THE WATER FLOWING THROUGH THE MEASURE, AND TOFACILITATE THE SETTLING OF SEDIMENT FROM THE WATER BEFOREDISCHARGE. POROUS BAFFLE EROSION CONTROL MEASURE - INITIAL PHASE: 1. ENSURE ALL APPROVALS HAVE BEEN OBTAINED PRIOR TO ANY LAND DISTURBANCE. 2. CONDUCT ON-SITE PRE-CONSTRUCTION MEETING WITH THE CONTRACTOR, OWNER, ENGINEER AND CONSTRUCTION MANAGER TO REVIEW THE PROJECT AND EROSION CONTROL SEQUENCES. 3. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WITHIN AND IMMEDIATELY ADJACENT TO THE PROJECT AREA. 4. INSTALL CONSTRUCTION ENTRANCE AT LOCATION SHOWN ON THE PLAN - OFF OF EDGE OF EXISTING PAVEMENT ON MARKS ROAD. 5. FLAG LIMITS OF ALL DISTURBED AREA AS SHOWN ON THE PLANS FOR INSTALLATION OF PERIMETER EROSION CONTROL DEVICES - SILT FENCE AND SILT FENCE OUTLET AND SEDIMENT BASIN WHERE SHOWN ON THE PLANS. 6. INSTALL ALL SILT FENCE AND SEDIMENT BASINS AS SHOWN ON THE PLANS. 7. CONSTRUCT PERMANENT DIVERSION DITCHES AS SHOWN ON THE PLANS. 8. “EROSION AND SEDIMENT CONTROL(E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF THE PLAN MUST BE KEPT ON SITE,PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION.” THE COC CAN BE OBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (E-NOI) FORM ATDEQ.NC.GOV/NCG01. PLEASE NOTE, THE E-NOI FORM MAY ONLY BE FILLED OUT ONCE THEPLANS HAVE BEEN APPROVED. 9. WITHIN 14 CALENDER DAYS OF COMPLETION OF ANY PHASE OF GRADING, GROUND COVER SHALL BE PROVIDED ON EXPOSED SLOPES AND PERMANENT GROUND COVER SHALL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 14 CALENDER DAYS OR 60 CALENDER DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 10. THE CONTRACTOR SHALL CONDUCT SELF-INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL MEASURES AND COMPLETE THE FOLLOWING COMBINED SELF-INSPECTION FORM FOUND ON THE DEMLR WEBSITE : https://files.nc.gov/ncdeq/Energy%20Mineral%20and%20Land%20Resources/Stormwater /NPDES%20General%20Permits/DEMLR-CSW-Monitoring-Form-Rev-August-8-2019.pdf TWELVE MONTHS OF COMPLETE INSPECTION FORMS SHALL BE KEPT ON-SITE AND AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. (GS 113A-54.1 (E), 15ANCAC 04B.0131, NCG01 PART III SECTIONS A AND B). 11. CLEAR AND GRUB SITE (WHERE REQUIRED) AND LEGALLY DISPOSE OF ALL DEBRIS OFF SITE. 12. “SELF-INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY NEEDED REPAIRS SHALL BE MADEIMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC MEASURES SHALL BE MAINTAINED AS SPECIFIED IN THE CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED AT THE PROJECT SITE FOR MONITORING. 13. TOTAL SITE DISTURBED AREA = 25.83 AC. CALCULATE SKIMMER SIZE DAYS TO DRAIN*3.6 DAYS SKIMMER SIZE ORIFICE RADIUS ORIFICE DIAMETER 4.0 2.0 INCH INCHES 4.0 INCHES MAXIMUM HEIGHT OF FLOAT WHEN NO OTHER STORM WATER DISCHARGE OPENINGS EXIST (MAJOR STORM EVENT) SCALE: N.T.S. 15" RCP OUTLET PIPE STORM WATER DISCHARGE OPENING EARTHEN EMBANKMENT PVC VENT PIPE WATER ENTRY UNIT WITH TRASH SCREEN ORIFICE OPENING INSIDE THE HORIZONTAL TUBE WITH A CONSTANT HYDRAULIC HEAD FLOAT WATER ENTRY UNIT FLEXIBLE HOSE SCHEDULE 40 PVC PIPE (BARREL OR ARM) GENERAL NOTES: 1. PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE. 2. PROPER ORIFICE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OFTIME. MODIFICATIONS MAY BE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE. 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE DISCHARGE END OF THE PIPE. 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUT SHEET, AND INSTRUCTIONS ON WEB SITE FOR EACH SIZE. TOP VIEW END VIEW SIDE VIEW L = 1.4 X DEPTH TO THE OVERFLOW MINIMUM LENGTH APPLIES SEE POND CONTROL STRUCTURE DETAIL SHEET C-8.0 SCHEDULE 40 PVC PIPE (BARREL OR ARM) FLEXIBLE HOSE MUST BE SECURELY FASTENED TO THE WATER QUALITY DISCHARGE OPENING OR TEMPORARY PLATE. SEE CONTROL STRUCTURE DETAIL FLOAT PVC VENT PIPE ~ WET POND ~ FAIRCLOTH SKIMMER DISCHARGE SYSTEM WITH PERMANENT OUTLET STRUCTURE INV = 317.00' TOP OF RIM = 318.50' INV = 316.00'' Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONFEETSCALE 0 100 200 HORZ.NORTHVICINITY MAP NOT TO SCALE 8 7 24 MARKS ROADSR1111CAMERONHILL ROADSR1108GILCH RIS T ROAD SR114 3 W R O A D SR1 1 1 0 RIPLEY R D SITE NOTE: PURSUANT TO G.S. 133-A57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION-CONTROL DEVICES OR STRUCTURES.IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 7 OR 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PERMANENT GROUNDCOVER WILL BE PROVIDED FORALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORE THAN 90 CALENDER DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUNDCOVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 CALENDAR DAYS OR 60 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. NOTE: EFFECTIVE OCTOBER1, 2010, PERSONS CONDUCTING LAND-DISTURBING ACTIVITIES LARGER THANONE ACRE MUST INSPECT THEIR PROJECT AFTER EACH PHASE OF THE PROJECT AND DOCUMENT THE INSPECTION IN WRITING. KEEP WRITTEN INSPECTION REPORTS ON CONSTRUCTION SITE IN WHICH IT SHOULD BE READILY AVAILABLE FOR EROSION CONTROL INSPECTOR'S REVIEW WHEN VISITING SITE. SELF-INSPECTION REPORT FORMS ARE AVAILABLE AS AN EXCEL SPREADSHEET FROM LAND QUALITY WEB SITE: www.dlr.enr.state.nc.us/pages/sedimentation_new.html LAND GRADING: PERIODICALLY CHECK ALL GRADED AREAS AND THE SUPPORTING EROSION AND SEDIMENTATION CONTROL PRACTICES, ESPECIALLY AFTER HEAVY RAINFALLS. PROMPTLY REMOVE ALL SEDIMENT FROM DIVERSIONS AND OTHER WATER-DISPOSAL PRACTICES. IF WASHOUT OR BREAKS OCCUR, REPAIR THEM IMMEDIATELY. PROMPT MAINTENANCE OF SMALL ERODED AREAS BEFORE THEY BECOME SIGNIFICANT GULLIES IS AN ESSENTIAL PART OF AN EFFECTIVE EROSION AND SEDIMENTATION CONTROL PLAN. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. OUTLET STABILIZATION STRUCTURE: INSPECT RIP RAP OUTLET STRUCTURES AFTER HEAVY RAINS TO SEE IF ANY EROSION AROUND OR BELOW THE RIP RAP HAS TAKEN PLACE OR IF STONES HAVE BEENDISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. DROP INLET PROTECTION (TEMPORARY): INSPECT THE FABRIC BARRIER AFTER EACH RAIN AND MAKE REPAIRS AS NEEDED. REMOVE SEDIMENT FROM THE POOL AREA AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE FABRIC DURING SEDIMENT REMOVAL. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN ADEQUATELY STABILIZED, REMOVE ALL MATERIALS AND ANY UNSTABLE SEDIMENT AND DISPOSE OF THEM PROPERLY. BRING THE DISTURBED AREA TO THE GRADE OF THE DROP INLET AND SMOOTH AND COMPACT IT. APPROPRIATELY STABILIZE ALL BARE AREAS AROUND THE INLET. SEDIMENT FENCE (SILT FENCE): INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. DUST CONTROL: MAINTAIN DUST CONTROL MEASURES THROUGH DRY WEATHER PERIODS UNTIL ALL DISTURBED AREAS HAVE BEEN STABILIZED. TREE PRESERVATION AND PROTECTION: REPAIR ANY DAMAGE TO PROTECTED TREE AS FOLLOW SHOULD DAMAGE TO CROWN, TRUNK, OR ROOT SYSTEM OCCUR. (REFERENCE NCDENR MANUAL, PAGE 6.05.3 AND 6.05.4) REPAIR ROOTS BY CUTTING OFF THE DAMAGED AREAS AND PAINTING THEM WITH TREE PAINT.SPREAD PEAT MOSS OR MOIST TOPSOIL OVER EXPOSED ROOTS. REPAIR DAMAGE TO BARK BY TRIMMING AROUND THE DAMAGED AREAS AS SHOWN IN FIGURE 6.05b, TAPER THE CUT TO PROVIDE DRAINAGE, AND PAINT WITH TREE PAINT. CUT OFF ALL DAMAGED TREE LIMBS ABOVE THE TREE COLLAR AT THE TRUNK OR MAIN BRANCH. USE THREE SEPARATED CUTS AS SHOWN IN FIGURE 6.05c TO AVOID PEELING BARK FROM HEALTHY AREAS OF THE TREE. EROSION CONTROL MAINTENANCE SCHEDULE EROSION CONTROL NARRATIVEC3.3 120 200120 GERMAN MILLET SPECIES WINTER RYE (GRAIN) SPECIES KOBE LESPEDEZA SEEDING SCHEDULE NOTE OF BERMUDA OR SERICEA LESPEDEZA PER ONE SQUARE FOOT. TEMPORARY SUMMER SEED MIX MARCH 1 - SEPT. 1 SEPT. 1 - MARCH 1 TEMPORARY WINTER SEED MIX 60 30 25 SPECIES SERICEA LESPEDEZA COMMON BERMUDAPENSICOLA BAHIAGRASS SPECIES 1030KOBE LESPEDEZASERICEA LESPEDEZA (UNSCARIFIED) COMMON BERMUDA 30 * MULCH WATER REQUIRED FOR PERMANENT SEED MIX ONLY APPLY SUPERPHOSPHATE (0-49-0) AT A RATE OF 200 LB/ACRE APPLY FERTILIZER (10-10-10) AT A RATE OF 1000 LB/ACRE APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER. MAINTENANCE OF 400 GAL./ACRE MARCH 1 - JULY 1 SEPT. 1 - NOV. 1 PERMANENT FALL SEED MIX SOIL AMENDMENTS PERMANENT SPRING SEED MIX BE CHECKED FOR ADEQUACY ON JULY 15. AN ADEQUATE COVER SHALL HAVE 50 SPRIGSCALENDAR DAYS AND SUBJECT TO FURTHER DISTURBANCE. PERMANENT SEED MIX SHALLTEMPORARY SEED MIX SHALL BE USED FOR ALL AREAS EXPOSED GREATER THAN 21 MINIMUM OF 1" OF RAINFALL A WEEK (IF NOT SUPPLIED NATURALLY, CONTRACTOR APPLY LIME (GROUND AGRICULTURAL LIMESTONE) AT A RATE OF 4000 LB/ACRE SHALL SUPPLY THE REMAINING AMOUNT UNTIL GROUND COVER HAS BEEN ESTABLISHED). TO BE INCORPORATED INTO THE TOP 3 INCHES OF SOIL IN AREAS WITH SLOPES 2:1 OR FLATTER ANCHOR MULCH WITH ROVING, NETTING OR BY TACKING WITH ASPHALT EMULSION AT A RATE (TO BE FOLLOWED BY PERMANENT FALL SEED MIX) RATE (LB./ACRE) RATE (LB./ACRE) (TO BE FOLLOWED BY PERMANENT SPRING SEED MIX) RATE (LB./ACRE) RATE (LB./ACRE) MOW WHEN THE AVERAGE PLANT HEIGHT EXCEEDS 6 INCHES.RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. REFERTILIZE IN THE SECOND YEAR UNLESS THE GROWTH IS FULLY ADEQUATE. ALL OTHER AREASWITH SLOPESFLATTER THAN 4:1 SLOPES 3:1 ORFLATTER 14 DAYS SLOPES STEEPERTHAN 3:1 14 DAYS 7 DAYS HIGH QUALITY WATER(HQW) ZONESFLATTER THAN 4:1 7 DAYS PERIMETER DIKES, SWALES, DITCHES ANDSLOPES 7 DAYS TYPICAL GROUND COVER STABILIZATION TYPES - GRASSAND OR SOD, WHEAT STRAW, MULCH, BIODEGRADABLESTRAW MATTING, SYNTHETIC MATTING, ETC. NONE NONE NONE(EXCEPT FOR PERIMETERAND HQW ZONES) IF SLOPES ARE 10' OR LESSIN LENGTH AND ARE NOTSTEEPER THAN 2:1 14 DAYSARE ALLOWED 7 DAYS FOR SLOPES GREATERTHAN 50 FEET IN LENGTH SITE AREADESCRIPTION STABILIZATIONTIME FRAME STABILIZATION TIMEFRAME EXCEPTIONS CONTRACTOR SHALL BE REQUIRED TO ESTABLISH GROUNDSTABILIZATION AS PER FOLLOWING CHART. GROUND STABILIZATION REQUIREMENTS APPLICABLETHIS PROJECT YES NO NO YES YES SEED BED PREPARATION APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE IN ACCORDANCE REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE MULCH IN ACCORDANCE WITH "SEEDING SCHEDULE" IMMEDIATELY AFTER SEEDING. INSPECT ALL SEEDING FOR COMPLIANCE WITH THE REQUIREMENTS OF THE "SEEDINGSCHEDULE". MAKE NECESSARY REPAIRS AND RESEED WITHIN THE PLANTING SEASON,IF POSSIBLE, OR THE DAMAGED AREA SHALL BE REESTABLISHED FOLLOWING THE ORIGINAL SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDINGEQUIPMENT OR CULTIPACK AFTER SEEDING. SEED ACCORDING TO "SEEDING SCHEDULE." CONTINUE TILLAGE UNTIL A WELL-PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED RIP THE ENTIRE AREA TO 6" DEPTH. REASONABLY SMOOTH AND UNIFORM. WITH "SEEDING SCHEDULE" AND MIX WITH SOIL. IS PREPARED 4 TO 6 INCHES DEEP. LIME, FERTILIZER, AND SEEDING REQUIREMENTS. 7. 2. 4. 5. 6. 3. 1. NATURE AND PURPOSE OF CONSTRUCTION THE PURPOSE OF THIS PROJECT IS TO PROVIDE ROAD ACCESS FOR RESIDENTIAL DEVELOPMENTSITE. THE PROJECT WILL INVOLVE CONSTRUCTION OF CONVEYANCE SWALE FOR STORMWATER DISCHARGE , SANITARY SEWER, WATER MAIN CONNECTION, STORM DRAINAGE SYSTEM AS WELL AS SANITARY AND WATER SERVICE LINES. THE SITE WILL BE PREPARED FOR INDIVIDUAL RESIDENTIALHOME CONSTRUCTION ON EACH LOT. PERMANENT VEGETATION SHALL BE ESTABLISHED QUICKLY UPON COMPLETION OF THE ROADWAYGRADING AND INFRASTRUCTURES IN ORDER TO REDUCE THE AMOUNT OF SEDIMENT RUNOFF FROM THE SITE. SITE IS NOT IN FLOOD PLAIN. NO WETLANDS EXIST ON THIS SITE PER INVESTIGATION REPORT BY HAL OWENS & ASSOCIATES, INC. DATE SEPTEMBER 6, 2022. EROSION CONTROL MEASURE - INITIAL PHASE: 1. ENSURE ALL APPROVALS HAVE BEEN OBTAINED PRIOR TO ANY LAND DISTURBANCE. 2. CONDUCT ON-SITE PRE-CONSTRUCTION MEETING WITH THE CONTRACTOR, OWNER, ENGINEER AND CONSTRUCTION MANAGER TO REVIEW THE PROJECT AND EROSION CONTROL SEQUENCES. 3. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WITHIN AND IMMEDIATELY ADJACENT TO THE PROJECT AREA. 4. INSTALL CONSTRUCTION ENTRANCE AT LOCATION SHOWN ON THE PLAN - OFF OF EDGE OF EXISTING PAVEMENT ON MARKS ROAD. 5. FLAG LIMITS OF ALL DISTURBED AREA AS SHOWN ON THE PLANS FOR INSTALLATION OF PERIMETER EROSION CONTROL DEVICES - SILT FENCE AND SILT FENCE OUTLET AND SEDIMENT BASIN WHERE SHOWN ON THE PLANS. 6. INSTALL ALL SILT FENCE AND SEDIMENT BASINS AS SHOWN ON THE PLANS. 7. CONSTRUCT TEMPORARY DIVERSION DITCHES AS SHOWN ON THE PLANS. 8. “EROSION AND SEDIMENT CONTROL(E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF THE PLAN MUST BE KEPT ON SITE, PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION.” THE COC CAN BE OBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (E-NOI) FORM ATDEQ.NC.GOV/NCG01. PLEASE NOTE, THE E-NOI FORM MAY ONLY BE FILLED OUT ONCE THE PLANS HAVE BEEN APPROVED. 9. WITHIN 14 CALENDER DAYS OF COMPLETION OF ANY PHASE OF GRADING, GROUND COVER SHALL BE PROVIDED ON EXPOSED SLOPES AND PERMANENT GROUND COVER SHALL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 14 CALENDER DAYS OR 60 CALENDER DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 10. THE CONTRACTOR SHALL CONDUCT SELF-INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL MEASURES AND COMPLETE THE FOLLOWING COMBINED SELF-INSPECTION FORM FOUND ON THE DEMLR WEBSITE : https://files.nc.gov/ncdeq/Energy%20Mineral%20and%20Land%20Resources/Stormwater /NPDES%20General%20Permits/DEMLR-CSW-Monitoring-Form-Rev-August-8-2019.pdf TWELVE MONTHS OF COMPLETE INSPECTION FORMS SHALL BE KEPT ON-SITE AND AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. (GS 113A-54.1 (E), 15ANCAC 04B.0131, NCG01 PART III SECTIONS A AND B). 11. CLEAR AND GRUB SITE (WHERE REQUIRED) AND LEGALLY DISPOSE OF ALL DEBRIS OFF SITE. 12. “SELF-INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC MEASURES SHALL BE MAINTAINED AS SPECIFIED IN THE CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED AT THE PROJECT SITE FOR MONITORING. 13. TOTAL SITE DISTURBED AREA = 25.83 AC. CONSTRUCTION SEQUENCE & EROSION CONTROL MEASURES - FINAL PHASE: 1. UPON COMPLETING ALL SITE IMPROVEMENTS AND FINAL GRADING, STABILIZE ALL DISTURBED AREAS PER LANDSCAPE PLAN. WATER AND MAINTAIN ALL LANDSCAPED AREAS TO ENSURE PROPER GROUND COVERAGE PRIOR TO FINAL APPROVAL 2. PERIMETER MEASURES, SILT FENCE AND TEMPORARY DIVERSION MUST BE LEFT INPLACE UNTIL ALL UPLAND AREAS ARE STABILIZED WITH PERMANENT VEGETATION. 3.SEE SEEDING SCHEDULE PROVIDED IN EROSION CONTROL DETAIL. 4. AFTER SITE IS PERMANENTLY STABILIZED,REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND PROVIDE PERMANENT SEEDING WHERE TEMPORARY MEASURES HAVE BEEN REMOVED AND GROUND COVER IS NOT ADEQUATE. SEDIMENT BASINS MAY NOT BE REMOVED OR CONVERTED TO PERMANENT BMPS UNTIL ALL UPLAND AREAS ARE PERMANENTLY STABILIZED. (GS 113A-57(3). 15A NCAC 04B. 0113) 5. WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT DEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (e-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE e-NOT HAS BEEN FILLED OUT. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONBASIN REMOVAL SEQUENCE: 1. SCHEDULE A SITE MEETING WITH THE ENVIRONMENTAL ENGINEER/CONSULTANT TO DETERMINE IF THE BASIN CAN BE REMOVED. INSTALL SILT FENCING AND EXTEND TO PROPERTY CORNER. 2. REMOVE BASIN AND ASSOCIATED TEMPORARY DIVERSION DITCHES. FINE GRADE AREAS IN PREPARATION FOR SEEDING. 3. PERFORM SEEDBED PREPARATION, SEED, MULCH AND ASPHALT TACH AND RESULTING BARE AREA IMMEDIATELY. 4. WHEN SITE IS FULLY STABILIZED, CALL NCDEQ FOR APPROVAL OF REMOVING REMAINING TEMPORARY EROSION CONTROL MEASURES AND ADVICE ON WHEN SITE CAN BE ISSUES A CERITIFICATE OF COMPLETION. CONSTRUCTION SEQUENCE & EROSION CONTROL MEASURES - CONSTRUCTION PHASE: 1. CHECK ALL SILT FENCE AND REPAIR AS NECESSARY. ASSURE ANY ERODED AREA ARE STABILIZED WITH TEMPORARY SEEDING AND MULCH. 2. ROUGH GRADE ROADWAY RIGHT OF WAY AREA. 3. INSTALL WATER SYSTEMS AS SHOWN ON THE PLANS. 4. INSTALL INLET / OUTLET BMP'S WHERE REQUIRED. 5. GRADE AND PREPARE SUBGRADE FOR PAVEMENT AREA. 6. PLACE COMPACTED G.A.B.C FOR ASPHALT CONSTRUCTION. 7. FINISH FINE GRADING THE ROAD RIGHT OF WAYS AND COMMON AREAS. 8. COMPLETE ALL REMAINING SITE IMPROVEMENTS. 9. PLACE ASPHALT, PAVEMENT MARKINGS, AND SIGNAGE. EROSION CONTROL GROUND STABILIZATIONAND SELF INSPECTION NOTESC3.4 NCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITHTHE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of ApprovedPAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak-proof containers that are kept under storm-resistant cover or surrounded by secondary containment structures. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on-site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off-site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit.HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen-material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. Site Area Description Timeframe variations -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed unless there is zero slope Stabilize within thismany calendardays after ceasingland disturbance 7 7 7 14 None None (a) Perimeter dikes, swales, ditches, and perimeter slopes (b) High Quality Water (HQW) Zones (c) Slopes steeper than 3:1 If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed (d) Slopes 3:1 to 4:1 (e) Areas with slopes flatter than 4:1 14 -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF-INSPECTION Self-inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self-inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical: (a) This General Permit as well as the Certificate of Coverage, after it is received. (b) Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically-available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard-copy records. PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that Must be Reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: ·They are 25 gallons or more, ·They are less than 25 gallons but cannot be cleaned up within 24 hours, ·They cause sheen on surface waters (regardless of volume), or ·They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d) Anticipated bypasses and unanticipated bypasses. (e) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368. 3. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non-surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non-surface withdrawal and the specific time periods or conditions in which it will occur. The non-surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non-surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION EROSION CONTROL DETAILC3.5 CONSTRUCTION SPECIFICATIONS: 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. 3. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTENANCE: 1. MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS.CONSTRUCTION ENTRANCE DETAIL TEMPORARY GRAVEL 100' M I N . 20' MIN. 40' MIN. NOT TO SCALE CE MATERIAL: 1. USE SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFIN OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D 6461. 2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.33 LB/LINEAR FT STEEL WITH A MINIMUM LENGTH OF 4 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. SILT FENCE DETAIL CONSTRUCTION SPECIFICATIONS: CONSTRUCTION: 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE GROUND SURFACE. 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO THE POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPEFROM THE BARRIER. 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE: 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUTS 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED.18" MAX.4" MIN.4'-0" MIN.FLOW NOTE: IMMEDIATELY. 12". REPAIR ANY UNDERMINE REMOVE SEDIMENT DEEPER THAN 8" MIN. SF SILT FENCE OUTLET DETAIL NOT TO SCALESFO NOT TO SCALE MAINTENANCE INSPECT DAM AND CHANNELS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE CHANNEL WHEN NEEDED. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS AROUND DAM, ADDITIONAL MEASURES CAN BE TAKEN SUCH AS, INSTALLING A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL (PRACTICE 6.31, RIPRAP-LINE AND PAVED CHANNELS). REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE DAM, AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONES TO DAM AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. CONSTRUCTION SPECIFICATIONS 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLEMATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. MAINTENANCE INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVESEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELYSTABILIZE IT. PD 6' (TYP.)6' (TYP.) 2' MIN. FLOW 18"MIN.COMPACTED SOIL PERMANENT DIVERSIONS SCALE: N.T.S. 1 2 CROSS SECTION FRONT VIEW TOP VIEW CLASS "B" STONE FOR EROSIONSTRUCTURAL STONE SHALL BE CONTROL PURPOSES. SEDIMENTCONTROL STONE SHALL BE#5 OR #57 STONE. OUTLETS TO BE PLACED ATLOW POINTS ALONG SILT FENCE. 1. NOTES: 2. 24" 18" MIN. FLOW SILT FENCE SILT FENCE 12" MAX. CONSTRUCTION SPECIFICATIONS 1. PLACE STONE TO THE LINES AND DIMENSIONS SHOWN IN THE PLAN ON A FILTER FABRIC FOUNDATION. 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL WHERE THE DAM ABUTS THE CHANNEL BANKS. 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BANK TO KEEP WATER FROM CUTTING AROUND THE ENDS OF THE CHECK DAM. 4. PROTECT THE CHANNEL AFTER THE DAM FROM HEAVY FLOW THAT COULD CAUSE EROSION. 6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE. 7. ENSURE THAT OTHER AREAS OF THE CHANNEL, SUCH AS CULVERT ENTRANCES BELOW THE DAM, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES. 8. SEE SILT FENCE DETAIL FOR CONSTRUCTION SPECIFICATIONS. WATERFILTERED WEIR4' MAX 19 GUAGE HARDWARE CLOTH -1/4" OPENINGS TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE TOP OF THE WASHED STONE. STEEL POST SEE SILT FENCE DETAIL INSTALL FILTER FABRIC UNDER RIP RAP AND GRAVEL NATURAL GROUND 12" THICK SEDIMENT CONTROL STONE STRUCTURAL STONE 2"-3" COURSE AGGREGATE @ 6" DEEP MINIMUM WITH FILTER FABRIC UNDERLINER WOVEN GEOSYNTHETICFILTER FABRIC STEEL POSTS 8' O.C. WITH WIREEXTEND FABRIC AND WIRE INTO TRENCH COMPACTEDBACKFILL Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION EROSION CONTROL DETAILC3.6 RIP RAP OUTLET PROTECTION CONSTRUCTION SPECIFICATIONS 1. ENSURE THAT THE SUBGRADE FOR THE FILTER AND RIPRAP FOLLOWS THE REQUIRED LINES AND GRADES SHOWN IN THE PLAN. COMPACT ANY FILL REQUIRED IN THE SUBGRADE TO THE DENSITY OF THE SURROUNDING UNDISTURBED MATERIAL. LOW AREAS IN THE SUBGRADE ON UNDISTURBED SOIL MAY ALSO BE FILLED BY INCREASING THE RIPRAP THICKNESS. 2. THE RIPRAP AND GRAVEL FILTER MUST CONFORM TO THE SPECIFIED GRADING LIMITS SHOWN ON THE PLANS. 3. FILTER CLOTH, WHEN USED, MUST MEET DESIGN REQUIREMENTS AND BE PROPERLY PROTECTED FROM PUNCHING OR TEARING DURING INSTALLATION.REPAIR ANY DAMAGE BY REMOVING THE RIPRAP AND PLACING ANOTHER PIECE OF FILTER CLOTH OVER THE DAMAGED AREA. ALL CONNECTING JOINTS SHOULD OVERLAP SO THE TOP LAYER IS ABOVE THE DOWNSTREAM LAYER A MINIMUM OF 1FOOT. IF THE DAMAGE IS EXTENSIVE, REPLACE THE ENTIRE FILTER CLOTH. 4. RIPRAP MAY BE PLACED BY EQUIPMENT, BUT TAKE CARE TO AVOID DAMAGING THE FILTER. 5. THE MINIMUM THICKNESS OF THE RIPRAP SHOULD BE 1.5 TIMES THE MAXIMUM STONE DIAMETER. 6. RIPRAP MAY BE FIELD STONE OR ROUGH QUARRY STONE. IT SHOULD BE HARD, ANGULAR, HIGHLY WEATHER-RESISTANT AND WELL GRADED. 7. CONSTRUCT THE APRON ON ZERO GRADE WITH NO OVERFILL AT THE END. MAKE THE TOP OF THE RIPRAP AT THE DOWNSTREAM END LEVEL WITH THE RECEIVING AREA OR SLIGHTLY BELOW IT. 8. ENSURE THAT THE APRON IS PROPERLY ALIGNED WITH THE RECEIVING STREAM AND PREFERABLY STRAIGHT THROUGHOUT ITS LENGTH. IF A CURVE IS NEEDED TOFIT SITE CONDITIONS, PLACE IT IN THE UPPER SECTION OF THE APRON. 9. IMMEDIATELY AFTER CONSTRUCTION, STABILIZE ALL DISTURBED AREAS WITH VEGETATION (PRACTICES 6.10, TEMPORARY SEEDING, AND 6.11, PERMANENT SEEDING). MAINTENANCE INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE.NOT TO SCALE OP NOTES: 1. ACTUAL LAYOUT TO BE DETERMINED IN FIELD. 2. THE "CONCRETE WASHOUT" SIGN SHALL BE INSTALLED WITHIN 30 FEET OF THE TEMPORARY CONCRETE WASHOUT FACILITY. 3. PIT CAPACITY IS MINIMUM OF 6 CUBIC FEET PER 10 CUBIC YARDS OF CONCRETE. PLAN VIEWSFSFSFSF SECTION A-A B SECTION B-B B A "CONCRETE WASHOUT" SIGN DETAILS CONCRETEWASHOUTAVEHICLE ENTRANCE6" WASH STONE 2:1 TOP RIM OF STONE BERM LINEDPITSUMP 2:11' 1' 2'1'6' 25' MINIMUM15' 1' 2'2'2' VEHICLE ENTRANCE @ 2% SLOPE 10 MIL. PLASTIC LINING PIT SUMP "CONCRETE WASHOUT" SIGN(SEE NOTE 2)2:1SILTFENCE SILTFENCE SILTFENCE 10 MIL. PLASTIC LINING PIT SUMP ANCHOR PLASTIC LINER WITH #57 STONE BERM ANCHOR PLASTIC LINERWITH #57 STONE BERM 2:11' 1' 2'1'6' 20' 1' 2'2'2'2'2' 1' 1' 1' SILT FENCE SIDE VIEW FRONT VIEW 0.5" LAGSCREWS 3' 3' 3"x3"x8'WOODPOSTS PLYWOOD 48"x24"PAINTED WHITE BLACKLETTERS 6"HEIGHT 2' 4' KEY IN REMOVABLE LINING CONCRETE WASHOUT PIT NOT TO SCALE CWP MAINTENANCE : 1. MAINTAINING TEMPORARY CONCRETE WASHOUT SHALL INCLUDEREMAINING AND DISPOSING OF HARDENED CONCRETE AND / ORSLURRY AND RETURNING THE FACILITIES TO A FUNCTIONALCONDITION. 2. FACILITY SHALL BE CLEANED OR RECONSTRUCTED IN A NEW AREAONCE WASHOUT BECOMES TWO-THIRDS Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION EROSION CONTROL DETAILC3.7 GENERAL NOTES : 1. PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGEPIPE. 2. PROPER ORIFICE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OF TIME. MODIFICATIONS MAY BE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE. 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE DISCHARGE END OF THE PIPE. 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUTSHEET, AND INSTRUCTIONS ON WEB SITE FOR EACH SIZE. SKIMMER DEWATERING DEVICE NOT TO SCALE MAINTENANCE 1. PULL SKIMMER OVER TO THE SIDE OF BASIN AND REMOVE DEBRIS AND EXCESS SEDIMENTS THAT HAVE ACCUMULATED FROM RAINFALL EVENTS. 2. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, JERK THE SKIMMER TO BOB UP AND DOWN TO DISLODGE THE DEBRIS AND RESTORE FLOW. CHECK ORIFICE INSIDE THE SKIMMER FOR CLOGGING AND REMOVE AS NEEDED. 3. IF SKIMMER ARM OR BARREL PIPE IS CLOGGED, REMOVE THE ORIFICE AND THE OBSTRUCTION CAN BE CLEAREDWITH PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. 1. CLEAR, GRUB, AND STRIP AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THEEMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL (TYPICALLY 4-INCH SCHEDULE 40 PVC PIPE) ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PREVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS A BACK FILL AROUND THE PIPE. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM THE FIRM CONTRACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACK FILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT, IN NO CASE SHOULD THE PIPE CONDUITBE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURES INSTRUCTIONS, OR AS DESIGNED. 6. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE. 7. EARTHEN SPILLWAYS - INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, ANDENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH THE LAMINATED PLASTIC OR IMPERMEABLE GEO TEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOMAND SIDES AND EXTEND ONTO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8-INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUSTBE ONE PIECE, NOT JOINED OR SPLICED; OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTIONSSHOULD OVERLAP THE LOWER SECTIONS SO THAT WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. (ADAPTED FROM " A MANUAL FOR DESIGNING, INSTALLING AND MAINTAINING SKIMMER SEDIMENT BASINS." FEBRUARY 1999 J.W. FAIR CLOTH & SON.) 8. INLETS - DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECTION). 9. EROSION CONTROL - CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENTBEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION ( REFERENCES: SURFACE STABILIZATION). 10. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65 11. AFTER ALL THE SEDIMENT-PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED,REMOVE THE STRUCTURE AND AIL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY ( REFERENCES: SURFACE STABILIZATION). INSPECT SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE BATTLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE-ANCHOR THE BAFFLES IF WATER IS FLOWINGUNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLYJERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE AND REMOVE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER FOR DEBRIS. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH THE FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. CONSTRUCTION SPECIFICATION MAINTENANCE SB SCALE: N.T.S. SEDIMENT BASIN INLET F L O W 5' WID T H SUPPORT ROPETO WIRE TO PREVENT SAGGING STAKE TO SUPPORT WIRE BAFFLE SECTION BAFFLE PLAN STEEL POST (TYP.) CONSTRUCTION SPECIFICATIONS: GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. INSTALL POSTS OR SAW HORSES ACROSS THE WIDTH OF THE SEDIMENT TRAP. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24", SPACED A MAXIMUM OF 4' APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THE FABRIC SHOULD BE 6" HIGHER THAN THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2" LOWER THAN THE TOP OF THE BERMS. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND OUTLET DISHARGE POINT. BASINS LESS THAN THE TOP OF THE BERMS. WHEN USING POSTS, ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. WRAP POROUS MATERIAL, LIKE JUTE BACKED BY COIR MATERIAL, OVER A SAWHORSE OR THE TOP WIRE. HAMMER REBAR INTO THE SAWHORSE LEGS FOR ANCHORING. THE FABRIC SHOULD HAVE FIVE TO TEN PERCENT OPENINGS IN THE WEAVE. ATTACH FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH ZIP TIES, WIRE OR STAPLES. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED IN A TRENCH OR PINNED WITH 8" EROSION CONTROL MATTING STAPLES. DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN MAINTENANCE: INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLECOLLAPSE, TEAR DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS WHEN IT REACHED HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PROESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DURING CLEANOUT. SEDIMENT DEPTHSHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. AFTER CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE, AND STABILIZE IT. COIR MESH OR SIMILAR,STAPLED OR TRENCHEDINTO BOTTOM OR SIDE INLET ZONE35% OF SURFACE AREA FIRST CHAMBER 25% OF SURFACE AREA OUTLET OUTLET ZONE 15% OF SURFACE AREA SECOND CHAMBER25% OF SURFACE AREA BAFFLE (TYP.) SUPPORT POST 24" INTO BOTTOM OR SIDE (TYP.) BAFFLES FOR TEMPORARY SEDIMENT TRAPS NOT TO SCALEBF STANDARD SKIMMER ATTACHED TO PERMANENT RISER NOTES: 1. BASIN SHOULD BE CLEANED OUT WHEN CAPACITY REACHES AN ELEVATION REPRESENTING THAT THE BASIN IS HALF-FULL 2. THE TARP USED TO PROTECT THE WEIR SHALL BE THE WIDTH SPECIFIED. THE LENGTH OF THE TARP SHALL BE ACCORDING TO AVAILABLE SUPPLY. IF MULTIPLE TRAPS ARE TO BE USED, THEN TARPS SHALL BE OVERLAPPED AT LEAST 12". THE UPSTREAM 12" TARP SHALL OVERLAP THE DOWNSTREAM TARP. THE TARP SHALL BE 50 MIL HEAVY DUTY SILVER TARPAULINS OR EQUIVALENT FOR U.V. RESISTANCE 3. PROVIDE MINIMUM OF THREE POROUS BAFFLES TO EVENLY DISTRIBUTE FLOW ACROSS THE BASIN, REDUCING TURBULENCE. 4. BAFFLE MATERIAL MUST BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR A SILT FENCE.5. MOST OF THE SEDIMENT WILL ACCUMULATE IN THE FIRST DAY, SO THIS SHOULD BE READILY AVAILABLE FOR MAINTENANCE. 6. DURING THE CONSTRUCTION PHASE OF THE PROJECT, PERMANENT STORMWATER RISER SHALL ONLYDEWATER FROM THE TOP OF THE PIPE. 7. POND SHALL NOT BE CONVERTED FOR STORMWATER USE UNTIL APPROVED BY ENVIRONMENTAL ENGINEER. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION 34134234334233833934033934034134134234334334234434434534634512345678932333435363738394041CONTROL CORNEREXISTING IRON POSTNC GRID COORDINATESNORTH:541,704.45'EAST: 1,972,681.74'NAD 83 (2011)MARKS ROAD - NCSR 111160' PUBLIC ROWwater-8"ex. water-6"0+000+501+001+502+002+503+003+504+004+505+005+506+006+507+007+508+008+509+009+5010+0010+5011+000+000+501+001+502+002+503+003+504+004+505+005+506+006+507+007+508+008+509+009+5010+0010+5011+00325327329331333335337339341343345347349351353355FIRE HYDRANTASSEMBLYPROPOSEDGRADEEXISTING GRADE40 LF 16" STEELCASING BORE & JACK1-6"X8" REDUCERFIRE HYDRANTASSEMBLYPC 350 RJ DIP INSIDEBORE AND JACK. SEEDETAIL.8" SDR-21 PVCWATER LINE15" CLASS V RCPCULVERTINV = 348.5'±24"MIN. (TYP.)1-6" X 6" TAPPING SLEEVEAND 6" GATE VALVE3' MIN. (TYP.)0'SCALE IN FEET25 50100MATCHLINE STA. 11+00 Know what's belowCall before you dig.Dial 811Or Call 800-632-4949123417 Winterwind Circle, Sanford, NC 27330 PO Box 249, Sanford, NC 27331 Phone: (919) 352-2834 e-mail: jhilliard@hilliardengineering.com NC License #: P-0836DESIGNED BY:DRAWN BY:APPROVED BY:SHEET:CIVILNO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH-JEHCEDAR POINTE SPRING LAKE, NORTH CAROLINA PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION MATCHLINE STA. 11+00 WATER MAIN PLAN & PROFILE C4.0FEETSCALE050100HORZ.FEETSCALE0510VERT.25' REAR LOTDRAINAGE EASEMENTSTA. 0+48.00FIRE HYDRANTASSEMBLYDOUBLE WATERMETER(TYP OF ALL)1- 6" X 8" REDUCEREX. 6' WATER MAIN8" SDR-21 PVCWATER LINE6"X6" TAPPINGSLEEVE AND VALVE40 LF 16" STEEL CASINGBORE AND JACK1- 8" 22.5° BENDWATERMAIN PROFILE VIEWSCALE: HORIZ. 1"=50' VERT. 1"=5'WATERMAIN PLAN VIEWSCALE: 1"=50'8" SDR-21 PVCWATER LINE3' (TYP.)STA. 10+00FIRE HYDRANTASSEMBLY 128.17'200.95'144.15'N 20°03'58" W 80.29'N 07°24'59" W 44.86' N 19°13'59" W 1 6 9 . 8 4 'N 07°24'59" W 60.24'S 86°20'11" E 887.64' TOTALN 78°09'28" W 849.44'S 17°44'15" W 259.41' TOTALN 78°12'14" W 884.55'1/2" SOLID IRON1/2" SOLID IRON1/2" SOLID IRON1/2" SOLID IRON DEED BOOK 4093, PAGE 969574-02-4063JARAMILLO-RUVALCABE JOSE DEJESUSDEED BOOK 3927, PAGE 0001RUSSELL SKYLER MASONDEED BOOK 3864, PAGE 813 JANSEN JEREMIAH D & JANSEN MICHELLE ADEED BOOK 3241, PAGE 605SMITH ELI EVERETTDEED BOOK 4111, PAGE 1829574-10-2850314 315 316 320319318 317 314315 316 320 319 318 317 328 327326325 324 323 322 329330 329328327326325324323330322314315316 320319318317 320 319 318 321 314 320 319 318 317 316 315 321 314 315 316 320319318317 321 321.50321.50321.50323324325326324325324324325326325323323324321322323320325326326325324327327328329330331335339340341342332333334333335333334335334335335336337336338338337336 33833733833733633833910+5011+0011+5012+0012+5013+0013+5014+0014+5015+0015+5016+0016+5017+0017+5018+0018+5019+0019+5019+80.66101112131415161718192021222324252627282930313233water-8water-6water-6water-211+0011+5012+0012+19.3412+5013+0013+5014+0014+5015+0015+5016+0016+5017+0017+5018+0018+5019+0019+5020+0020 + 5 0 20+91.1211+0011+5012+0032532732933133333533934134334534734935135335512+0012+5013+0013+5014+0014+5015+0015+5016+0016+5017+0017+5018+0018+5019+0019+5019+5020+0020+5021+00325327329331333335337339341343345347349351353355FIRE HYDRANTASSEMBLY6" PLUG TAPPED2" NPT1-2" GATE VALVE2" SDR-21PVC WATER LINE8" X 6" REDUCER1-6" GATE VALVE2" BLOWOFFASSEMBLYPROPOSEDGRADEEXISTING GRADE6" SDR-21 PVCWATER LINE3' MIN. (TYP.)0'SCALE IN FEET25 50100WATERMAIN PROFILE VIEWSCALE: HORIZ. 1"=50' VERT. 1"=5'WATERMAIN PLAN VIEWSCALE: 1"=50'MATCHLINE STA. 11+00 Know what's belowCall before you dig.Dial 811Or Call 800-632-4949123417 Winterwind Circle, Sanford, NC 27330 PO Box 249, Sanford, NC 27331 Phone: (919) 352-2834 e-mail: jhilliard@hilliardengineering.com NC License #: P-0836DESIGNED BY:DRAWN BY:APPROVED BY:SHEET:CIVILNO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH-JEHCEDAR POINTE SPRING LAKE, NORTH CAROLINA PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION MATCHLINE STA. 11+00 WATER MAIN PLAN & PROFILE C4.1FEETSCALE050100HORZ.FEETSCALE0510VERT.25' REAR LOTDRAINAGE EASEMENTDRAINAGE EASEMENTOUTFALL STRUCTURESEE POND DETAIL20.0' DRN.ESMT.2" SDR-21 PVCWATER LINE2" BLOWOFFSINGLE WATERMETER(TYP OF ALL)STA. 19+631-6" PLUG TAPPED2" NPT1-2" GATE VALVESTA. 19+60FIRE HYDRANTASSEMBLYSTA. 12+19.348" X 6" REDUCER1-6" GATE VALVEDOUBLE WATERMETER(TYP OF ALL)STREET LIGHTS(TYP.)6" SDR-21 PVCWATER LINEDOUBLE WATERMETER(TYP OF ALL)STREET LIGHTS(TYP.)3' (TYP.) WATER AND SITE DETAILSC4.2Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONCENTER LINE CARRIER PIPE SPIDERS SUPPORT CARRIER PIPE IN CASING STEEL CASING PIPE 2" BEVEL 2" WEEP HOLE SLOPE TO DRAIN ENCLOS ENDS WITH 8" BRICK MASONRY GRAVEL 3'-0" ELEVATION TRANSITION FITTING AS REQUIRED BRICK CLOSURE ST'L. CASING PIPE DUCTILE IRON PIPE CARRIER 3'-0" MIN. COVER OR AS SHOWN ON THE PLANS. PAVEMENT (ONE OR TWO LANES) RAILROAD 5'-6" MIN. COVER OR AS SHOWN ON THE PLANS PROFILE NO SCALE TYPICAL BORING & JACKING DETAIL ON THE THRUST BLOCKING SCHEDULE. 5. VOLUME OF THRUST BLOCKING SHALL BE AS SHOWN BLOCKING. WITH 10 MIL. POLYETHYLENE PRIOR TO POURING 4. ALL PIPING AND ACCESSORIES TO BE WRAPPED 3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS. PART (BLOCKING AREA) AGAINST UNDISTURBED SOIL. SHAPE MORE EASILY FORMED WITH THE WIDEST FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE 2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT 1. CONCRETE SHALL BE 3,000 PSI MIN. NOTES: 12" 10" 8" 6" 8" 6" 8" 6" 8" 6" 8"8" 36" 34" 30" 25" 24" 18" 16" 20" 18" 16" 14" 12" 12" 10" 20" 18" 16" 14" 12" 10" 9" 18" 16" 14" 11" 10" 10" 8" 16" 14" 12" 10" 8" 6" 12" 10" 8" 6" 16" 14" 12" 10" 8"8" 18" 16" 14" 12" 10" 10" 8" 16" 14" 12" 10" 10" 8" 8" 20" 18" 16" 14" 13" 12" 12" 26" 22" 20" 16" 15" 10" 8" 16" 14" 12" 10" 8" 6" 4" C D A B A B A B A B A B PLUGTEE11/4° BEND221/2° BEND45° BEND90° BEND SIZE PIPE 24" MIN. - 12" OR LESS 18" MIN. - 10" OR LESS 18" MIN.SQDSQCBB45° 2 1/2" HOSE CONNECTION STEAMER CONNECTION CONC. ON PLANS AS SHOWN BLOCKING (SEE NOTE) WEEP HOLE TO REMAIN OPEN BACKFILL STONE (7 C.F. MIN.) 6" G.V. & C. I. BOX 4-3/4" TIE RODS WITH BRACKETS (SEE DETAIL) 6" HYDRANT TEE 6" WATER LINE NOTE: 1.)TIE HYDRANT TO MAIN LINE W/TIE RODS IN LIEW OF CONC. BLOCKING IN SANDY SOIL. PRECAST CONCRETE PROTECTION RING NO SCALE TYPICAL FIRE HYDRANT INSTALLATION DETAIL EDGE OF ROAD ON THE THRUST BLOCKING SCHEDULE. 5. VOLUME OF THRUST BLOCKING SHALL BE AS SHOWN BLOCKING. WITH 10 MIL. POLYETHYLENE PRIOR TO POURING 4. ALL PIPING AND ACCESSORIES TO BE WRAPPED 3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS. PART (BLOCKING AREA) AGAINST UNDISTURBED SOIL. SHAPE MORE EASILY FORMED WITH THE WIDEST FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE 2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT 1. CONCRETE SHALL BE 3,000 PSI MIN. NOTES: 12" 10" 8" 6" 8" 6" 8" 6" 8" 6" 8"8" 36" 34" 30" 25" 24" 18" 16" 20" 18" 16" 14" 12" 12" 10" 20" 18" 16" 14" 12" 10" 9" 18" 16" 14" 11" 10" 10" 8" 16" 14" 12" 10" 8" 6" 12" 10" 8" 6" 16" 14" 12" 10" 8"8" 18" 16" 14" 12" 10" 10" 8" 16" 14" 12" 10" 10" 8" 8" 20" 18" 16" 14" 13" 12" 12" 26" 22" 20" 16" 15" 10" 8" 16" 14" 12" 10" 8" 6" 4" C D A B A B A B A B A B PLUGTEE11/4° BEND221/2° BEND45° BEND90° BEND SIZE PIPE 24" MIN. - 12" OR LESS 18" MIN. - 10" OR LESS 18" MIN.SQDSQCBB45° PLAN TEES HYDRANT TEE PLAN BENDS X X 6" MIN. AA X X A A 6" MIN. NO SCALE TYPICAL THRUST BLOCK DETAIL SECTION "A" BOLTS TO PIPE STEEL SKIDS (4) HEAVY DUTY INNER PIPE.) SIZE OF STEEL CASING AND (SPIDER SIZE DETERMINED BY CARRIER PIPE 3/4" CHAMFER AT EA. CORNER 4" SQ. PRECAST CONC. POST (4000 P.S.I.) BRASS MARKER PLATE VALVE NO. 120 25 FT. PLATE WITH VALVE NUMBER, DIRECTIONAL ARROW-POINTED TO MARKED VALVE & DISTANCE TO THE NEAREST FOOT. MARKED PLATE WITH ANCHOR 4 #3 BARS NO SCALE TYPICAL VALVE MARKER DETAIL VM CAST THE LETTERS "MV" IN ONE FACE OF THE CONCRETE MARKER AND ORIENT TOWARD THE ROADWAY BOROTATE MARKER TO OTHER END FOR BLOW-OFF FINISHED GRADE VALVE BOX VALVE OPERATOR NUT NO SCALE TYPICAL VALVE BOX DETAIL PROTECTION RING PRECAST CONCRETE BACKFILL TO EDGE NOTE: AT PIPE INTERSECTIONS, MULTIPLE VALVES, RUN WIRE UP AT ONLY ONE VALVE. SINGLE 12 AWG SOLID CORE WIRE GATE VALVE TRACER WIRE TO BE LAID UNDERNEATH WATER LINE VALVE BOX FINISHED GRADE IN VALVE BOX NO. 1 DRILL HOLE FOR TRACER WIRE TRACER WIRE VALVE BOX P.V.C. PIPELINE NOTES: 1. DRILL HOLE IN VALVE BOX TO INSERT TRACER WIRE,BRING UP TO INSIDE AND ROLL UP AT LEAST 6"-8" EXCESS VALVE BOX 2. PLACE TRACER WIRE IN VALVE BOX AT 1,000 FT INTERVALS OR AS NOTED ON THE PLANS, TYPICAL. PLACE EMPTY VALVE BOX AT INTERVALS WHERE VALVES DO NOT OCCUR & PLACE TRACER WIRE IN BOX. NO SCALE TYPICAL TRACER WIRE INSTALLATION DETAIL 3. DO NOT SPLICE WIRE WHEN BEGINNING A NEW SPOOL. INSTEAD INSTALL A VALVE BOX AND ATTACH EACH WIRE WITH A BRASS SCREW TO THE VALVE BOX. NOTE: LOOPED IN BOX 6"-8" EXCESS PRECAST CONCRETE PROTECTION RING BACKFILL TO EDGE EXISTING WATER MAIN NEW WATER MAIN TAPPING VALVE WITH VALVE BOX NO SCALE TYPICAL TAPPING SLEEVE AND VALVE ASSEMBLY DETAIL TAPPING SLEEVE SHALL BE ROMAC BRAND MODEL SST MANUFACTURED WITH 316 STAINLESS STEEL. PE PLASTIC TO PROTECT TAPPING SLEEVE THRUST BLOCKING MASONRY BLOCK MASONRY BLOCK 2.)MECHANICAL JOINTS USED WITH GRIP RINGS A NOTE: ALL GATE VALVES SHALL BE PLACED ON AN 80 LB. BAG OF SACRETE. RESTRAINT JOINT 90° BENDS CAST IRON VALVE BOX TAPPING VALVE 24"x24"x6" THICK CONCRETE PAD CAST IN PLACE OR PRE-CAST 1/2" ALTERNATE TAPPING SLEEVE AND VALVE DETAIL NOT TO SCALE CONDITIONS LAYING DESCRIPTION PROJECT USE PIPE BEDDED IN 4" MININUM JOB EXCAVATED MATERIAL. BACKFILL LIGHTLY CONSOLIDATED TO TOP OF PIPE. PIPE BEDDED IN SAND, GRANULAR MATERIAL OR GRADED GRAVEL TO THE DEPTH OF 1/8 PIPE DIAMETER, 4" MIN. JOB EXCAVATED MATERIAL COMPACTED TO 4" ABOVE TOP OF PIPE. (APPROX. 95% STANDARD PROCTOR, AASHTO T-99) ALL DUCTILE IRON GRAVITY SEWER LINE. ALL PVC WATER LINE AND PVC FORCE MAIN. TYPE 3 TYPE 4 NO SCALE TYPICAL LAYING CONDITIONS DETAIL WATERMAIN DETAILC4.3Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONMETER SETTER CENTERED IN BOX 18" MIMINUM COVERTYPICAL 3/4" METER SETTER INSTALLATION DETAIL METER SETTER WITH DOUBLE CHECK VALVE (BACKFLOW PREVENTER) METER BOX LID, CAST IRON 1' FROM EDGE OF ROW SERVICE LINE FROM STREET 1. METER AND PRIVATE SERVICE LINE NOT IN CONTRACT UNLESS SPECIFIED 2. INCLUDE STONE IN PRICE OF METER BOX. 3. METER SETTER SIZE AS NOTED ON PLANS. 4. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE. 3/4" X 18" BRASS NIPPLERWPROPERTY METER TO BE INSTALLED BRICK SUPPORT VALVE BOX 24"x18" RECTANGULAR 17" 18" 24" 3 1/2" 18" 12" A BA ELEVATION ISOMETRIC PLAN NO SCALE TYPICAL METER BOX DETAIL FOR 3/4" SERVICE 16 3/4" 11" ABS PLASTIC NO SCALE TYPICAL PERMANENT BLOW-OFF ASSEMBLY DETAIL WATERMAIN STREET PROPERTYLINEPROPERTYLINER/W R/W NO SCALE TYPICAL DOMESTIC WATER SERVICE INSTALLATION DETAIL 1/2" SOLID IRON1/2" SOLID IRON1/2" SOLID IRON1/2" SOLID IRON339340341342338334330326322 328 329 331 33 2 33 3 330 33 4 323 315 316 317 319 320 321 324 325 327 314 322 326 318 323 319 320 321 324325 327 328329331332 333 322 326330334 318 336 337338 3 3 5 3 3 6 3 3 7 338 339340341342 339340341338342DEED BOOK 4093, PAGE 969574-02-4063JARAMILLO-RUVALCABE JOSE DEJESUSDEED BOOK 3927, PAGE 0001RUSSELL SKYLER MASONDEED BOOK 3864, PAGE 813 JANSEN JEREMIAH D & JANSEN MICHELLE ADEED BOOK 3241, PAGE 605SMITH ELI EVERETTDEED BOOK 4111, PAGE 1829574-10-2850314 315 316 320319318 317 314315 316 320 319 318 317 328 327326325 324 323 322 329330 329328327326325324323330322314315316 320319318317 320 319 318 321 314 320 319 318 317 316 315 321 314 315 316 320319318317 321 321.50321.50321.5033933933833833733733633633533533433433333333233233133133133032 9323324325326 324325324324325326325323323324321322323320325326326325324327327328329330331335339340341342332333334333335333334335334335335336337336338338337336 33833733833733633833910+5011+0011+50PC =11+62.26Rad =250.00'12+00PT =12+29.0712+5013+0013+5014+0014+5015+0015+5016+0016+5017+0017+5018+0018+5019+0019+5019+80.660+000+501+00 1+502+ 0 02+16.54101112131415161718192021222324252627282930313233EXISTING GRADEPROPOSEDGRADEPROPOSEDGRADE @ EOPEXISTING GRADE11+0011+5012+0012+5013+0013+5014+0014+5015+0015+5016+0016+5017+0017+5018+0018+5019+0019+5020+00325327329331333335337339341343345347349351353355356PVI STA = 19+80.66 PVI ELEV = 333.50 -1.20%PVI STA = 11+71.20PVI ELEV = 341.56BVCS: 11+46.20BVCE: 341.68'EVCS: 11+96.20EVCE: 341.26 50.00' VCAD = -0.70K = 71.21-0.50%PVI STA = 14+56.77PVI ELEV = 338.12BVCS: 14+31.77BVCE: 338.42'EVCS: 14+81.77EVCE: 338.00 50.00' VCAD = 0.70K = 71.21-1.05%PVI STA = 16+13.88PVI ELEV = 337.34BVCS: 15+88.88BVCE: 337.46' EVCS: 16+38.88 EVCE: 337.08 50.00' VCAD = -0.55K = 91.46HORZ: 1" = 50VERT: 1" = 50+000+501+001+502+00324326328330332334336338340324326328330332334336338340PVI STA = 0+00PVI ELEV = 333.77 PVI STA = 2+16.54PVI ELEV = 333.77-1.15%1.19%PVI STA = 1+10.20PVI ELEV = 332.50BVCS: 1+05.20 BVCE: 332.56'LP STA = 1+10.11LP ELEV = 332.53'EVCS: 1+15.20 EVCE: 332.56 10.00' VCAD = 2.34K = 4.282" SDR-21PVC WATER LINE6" SDR-21 PVCWATER LINEFIRE HYDRANTASSEMBLY0'SCALE IN FEET25 50100PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD 'A' PROFILESCALE: HORIZ. 1"=50' VERT. 1"=5'ROAD 'A' PLAN VIEWSCALE: 1"=50'MATCHLINE STA. 11+00 Know what's belowCall before you dig.Dial 811Or Call 800-632-4949123417 Winterwind Circle, Sanford, NC 27330 PO Box 249, Sanford, NC 27331 Phone: (919) 352-2834 e-mail: jhilliard@hilliardengineering.com NC License #: P-0836DESIGNED BY:DRAWN BY:APPROVED BY:SHEET:CIVILNO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH-JEHCEDAR POINTE SPRING LAKE, NORTH CAROLINA PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION MATCHLINE STA. 11+00 ROAD PLAN AND PROFILE C5.1ROAD CUL-DE-SAC PROFILESCALE: HORIZ. 1"=50' VERT. 1"=5'FEETSCALE050100HORZ.FEETSCALE0510VERT.REFERENCE ROAD CROSS SECTIONFOR BOTTOM OF DITCH ELEVATION(TYP OF ALL)NOT TO SCALEREAR YARD PERMANENT SWALE13 GRASS LINED SWALE WITH BERMBOTTOM WIDTH(VARIES)MIN. DEPTH1.0'SEED, MULCH AND TACKDISTURBED SLOPE IMMEDIATELYUPON SWALE CONSTRUCTIONEXISTING GRADE313125' REAR LOTDRAINAGE EASEMENT25' REAR LOTDRAINAGE EASEMENTDRAINAGE EASEMENTDRAINAGE EASEMENTPERMANENT DIVERSION SWALE WITH BERM 01BBOTTOM WIDTH: 7.0'MIN. DEPTH: 1.0'BERM HEIGHT: 0.50'TOTAL DEPTH FROM TOP OF BERMTO BOTTOM OF DITCH: 1.5'TOP OF BERM WIDTH: 2.0'BOTTOM OF BERM WIDTH: 6.0'SIDE SLOPE: 3:1LINING: SEED AND MULCH WITHCONTRACTOR'S BLEND ANDEXCELSIOR MATTING OR EQUIVALENT.PERMANENT DIVERSION SWALE WITH BERM 01ABOTTOM WIDTH 4.0'MIN. DEPTH: 1.0'BERM HEIGHT: 0.56'TOTAL DEPTH FROM TOP OF BERMTO BOTTOM OF DITCH: 1.5'TOP OF BERM WIDTH: 2.0'BOTTOM OF BERM WIDTH: 6.0'SIDE SLOPE: 3:1LINING: SEED AND MULCH WITHCONTRACTOR'S BLENDAND NAG S75 MATTING OR EQUIVALENTPERMANENT DIVERSION SWALE WITH BERM 03BOTTOM WIDTH 3.0'MIN. DEPTH: 1.0'BERM HEIGHT: 0.58'TOTAL DEPTH FROM TOP OF BERMTO BOTTOM OF DITCH: 1.5'TOP OF BERM WIDTH: 2.0'BOTTOM OF BERM WIDTH: 6.0'SIDE SLOPE: 3:1LINING: SEED AND MULCH WITHCONTRACTOR'S BLENDAND NAG S75 MATTING OR EQUIVALENTOUTFALL STRUCTURESEE POND DETAIL20.0'EOP-EOP50.0'ROWR35.0'EOPR45.0'ROWR17.0'TYP., BOTH SIDE20.0' DRN.ESMT.NCDOT STANDARD NOTES:1. ALL UTILITY STRUCTURES SHALL BE LOAD RATED FOR THE APPROPRIATEDEAD LOAD PLUS HL-93 LIVE LOAD. SUCH STRUCTURES SHALL BEDESIGNATED AND CERTIFIED BY A LICENSED PE OR DESIGNATED ASMEETING NCDOT STANDARD SPECIFICATIONS AND DRAWINGS.2. ELECTRICAL POWER AND COMMUNICATIONS FACILITIES SHOULDCONFORM TO THE CURRENTLY APPLICABLE NATIONAL ELECTRICAL SAFETYCODE EXCEPT VERTICAL CLEARANCES SHALL BE NO LESS THAN 18 FEET INANY CASE.3. ALL NON-FERROUS PIPELINES SHALL BE INSTALLED WITH A LOCATINGTAPE.4. ANY SUBDIVISION MARKER WILL NEED TO BE LOCATED OUTSIDE OFRIGHT OF WAY.IMMEDIATELY STABILIZED ROADSIDEDITCH WITH SEED AND MULCHWITH CONTRACTOR'S BLENDAND EXCELSIOR MATTING OR EQ. CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 H = 1 : 10 V = 1 : 50+00ELEV. 350.45' DITCHELEV. 348.45' DITCHELEV. 350.11' SHOULDERELEV. 350.59' EOPELEV. 350.79' CENTERELEV. 350.59' EOPELEV. 350.11' SHOULDERELEV. 348.45' DITCHELEV. 350.45' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 0+09.64ELEV. 350.43' DITCHELEV. 348.43' DITCHELEV. 350.10' SHOULDERELEV. 350.58' EOPELEV. 350.78' CENTERELEV. 350.58' EOPELEV. 350.10' SHOULDERELEV. 348.43' DITCHELEV. 350.43' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 0+25ELEV. 350.35' DITCHELEV. 348.35' DITCHELEV. 350.02' SHOULDERELEV. 350.50' EOPELEV. 350.70' CENTERELEV. 350.50' EOPELEV. 350.02' SHOULDERELEV. 348.35' DITCHELEV. 350.35' DITCH 1:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 0+50ELEV. 350.23' DITCHELEV. 348.23' DITCHELEV. 349.90' SHOULDERELEV. 350.38' EOPELEV. 350.58' CENTERELEV. 350.38' EOPELEV. 349.90' SHOULDERELEV. 348.23' DITCHELEV. 350.23' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 0+75ELEV. 350.10' DITCHELEV. 348.10' DITCHELEV. 349.77' SHOULDERELEV. 350.25' EOPELEV. 350.45' CENTERELEV. 350.25' EOPELEV. 349.77' SHOULDERELEV. 348.10' DITCHELEV. 350.10' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 1+00ELEV. 349.98' DITCHELEV. 347.98' DITCHELEV. 349.65' SHOULDERELEV. 350.13' EOPELEV. 350.33' CENTERELEV. 350.13' EOPELEV. 349.65' SHOULDERELEV. 347.98' DITCHELEV. 349.98' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 1+25ELEV. 349.85' DITCHELEV. 347.85' DITCHELEV. 349.52' SHOULDERELEV. 350.00' EOPELEV. 350.20' CENTERELEV. 350.00' EOPELEV. 349.52' SHOULDERELEV. 347.85' DITCHELEV. 349.85' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 1+50ELEV. 349.73' DITCHELEV. 347.73' DITCHELEV. 349.40' SHOULDERELEV. 349.88' EOPELEV. 350.08' CENTERELEV. 349.88' EOPELEV. 349.40' SHOULDERELEV. 347.73' DITCHELEV. 349.73' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 1+75ELEV. 349.60' DITCHELEV. 347.60' DITCHELEV. 349.27' SHOULDERELEV. 349.75' EOPELEV. 349.95' CENTERELEV. 349.75' EOPELEV. 349.27' SHOULDERELEV. 347.60' DITCHELEV. 349.60' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 2+00ELEV. 349.48' DITCHELEV. 347.48' DITCHELEV. 349.15' SHOULDERELEV. 349.63' EOPELEV. 349.83' CENTERELEV. 349.63' EOPELEV. 349.15' SHOULDERELEV. 347.48' DITCHELEV. 349.48' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 2+25ELEV. 349.35' DITCHELEV. 347.35' DITCHELEV. 349.02' SHOULDERELEV. 349.50' EOPELEV. 349.70' CENTERELEV. 349.50' EOPELEV. 349.02' SHOULDERELEV. 347.35' DITCHELEV. 349.35' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 2+50ELEV. 349.23' DITCHELEV. 347.23' DITCHELEV. 348.90' SHOULDERELEV. 349.38' EOPELEV. 349.58' CENTERELEV. 349.38' EOPELEV. 348.90' SHOULDERELEV. 347.23' DITCHELEV. 349.23' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONKnow what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD CROSS SECTIONSC5.2 FEETSCALE 0 10 20 HORZ. FEETSCALE 0 5 10 VERT. CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 2+75ELEV. 349.10' DITCHELEV. 347.10' DITCHELEV. 348.77' SHOULDERELEV. 349.25' EOPELEV. 349.45' CENTERELEV. 349.25' EOPELEV. 348.77' SHOULDERELEV. 347.10' DITCHELEV. 349.10' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 3+00ELEV. 348.98' DITCHELEV. 346.98' DITCHELEV. 348.65' SHOULDERELEV. 349.13' EOPELEV. 349.33' CENTERELEV. 349.13' EOPELEV. 348.65' SHOULDERELEV. 346.98' DITCHELEV. 348.98' DITCH 1:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 3+25ELEV. 348.85' DITCHELEV. 346.85' DITCHELEV. 348.52' SHOULDERELEV. 349.00' EOPELEV. 349.20' CENTERELEV. 349.00' EOPELEV. 348.52' SHOULDERELEV. 346.85' DITCHELEV. 348.85' DITCH 1:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 3+50ELEV. 348.73' DITCHELEV. 346.73' DITCHELEV. 348.40' SHOULDERELEV. 348.88' EOPELEV. 349.08' CENTERELEV. 348.88' EOPELEV. 348.40' SHOULDERELEV. 346.73' DITCHELEV. 348.73' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 3+75ELEV. 348.59' DITCHELEV. 346.59' DITCHELEV. 348.26' SHOULDERELEV. 348.74' EOPELEV. 348.94' CENTERELEV. 348.74' EOPELEV. 348.26' SHOULDERELEV. 346.59' DITCHELEV. 348.59' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 4+00ELEV. 348.36' DITCHELEV. 346.36' DITCHELEV. 348.03' SHOULDERELEV. 348.51' EOPELEV. 348.71' CENTERELEV. 348.51' EOPELEV. 348.03' SHOULDERELEV. 346.36' DITCHELEV. 348.36' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 4+25ELEV. 348.03' DITCHELEV. 346.03' DITCHELEV. 347.69' SHOULDERELEV. 348.17' EOPELEV. 348.37' CENTERELEV. 348.17' EOPELEV. 347.69' SHOULDERELEV. 346.03' DITCHELEV. 348.03' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 4+50ELEV. 347.68' DITCHELEV. 345.68' DITCHELEV. 347.34' SHOULDERELEV. 347.82' EOPELEV. 348.02' CENTERELEV. 347.82' EOPELEV. 347.34' SHOULDERELEV. 345.68' DITCHELEV. 347.68' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 4+75ELEV. 347.33' DITCHELEV. 345.33' DITCHELEV. 346.99' SHOULDERELEV. 347.47' EOPELEV. 347.67' CENTERELEV. 347.47' EOPELEV. 346.99' SHOULDERELEV. 345.33' DITCHELEV. 347.33' DITCH 1:- 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 5+00ELEV. 346.98' DITCHELEV. 344.98' DITCHELEV. 346.64' SHOULDERELEV. 347.12' EOPELEV. 347.32' CENTERELEV. 347.12' EOPELEV. 346.64' SHOULDERELEV. 344.98' DITCHELEV. 346.98' DITCH 1: - 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 5+25ELEV. 346.63' DITCHELEV. 344.63' DITCHELEV. 346.29' SHOULDERELEV. 346.77' EOPELEV. 346.97' CENTERELEV. 346.77' EOPELEV. 346.29' SHOULDERELEV. 344.63' DITCHELEV. 346.63' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 5+50ELEV. 346.28' DITCHELEV. 344.28' DITCHELEV. 345.94' SHOULDERELEV. 346.42' EOPELEV. 346.62' CENTERELEV. 346.42' EOPELEV. 345.94' SHOULDERELEV. 344.28' DITCHELEV. 346.28' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONKnow what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD CROSS SECTIONSC5.3 FEETSCALE 0 10 20 HORZ. FEETSCALE 0 5 10 VERT. CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 5+75ELEV. 345.93' DITCHELEV. 343.93' DITCHELEV. 345.59' SHOULDERELEV. 346.07' EOPELEV. 346.27' CENTERELEV. 346.07' EOPELEV. 345.59' SHOULDERELEV. 343.93' DITCHELEV. 345.93' DITCH 1:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 6+00ELEV. 345.58' DITCHELEV. 343.58' DITCHELEV. 345.24' SHOULDERELEV. 345.72' EOPELEV. 345.92' CENTERELEV. 345.72' EOPELEV. 345.24' SHOULDERELEV. 343.58' DITCHELEV. 345.58' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 6+25ELEV. 343.23' DITCHELEV. 344.89' SHOULDERELEV. 345.37' EOPELEV. 345.57' CENTERELEV. 345.37' EOPELEV. 344.89' SHOULDERELEV. 343.23' DITCHELEV. 345.23' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 6+50ELEV. 342.88' DITCHELEV. 344.54' SHOULDERELEV. 345.02' EOPELEV. 345.22' CENTERELEV. 345.02' EOPELEV. 344.54' SHOULDERELEV. 342.88' DITCHELEV. 344.88' DITCH 1:- 2 . 1 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 6+75ELEV. 342.53' DITCHELEV. 344.19' SHOULDERELEV. 344.67' EOPELEV. 344.87' CENTERELEV. 344.67' EOPELEV. 344.19' SHOULDERELEV. 342.53' DITCHELEV. 344.53' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 7+00ELEV. 342.18' DITCHELEV. 343.84' SHOULDERELEV. 344.32' EOPELEV. 344.52' CENTERELEV. 344.32' EOPELEV. 343.84' SHOULDERELEV. 342.18' DITCHELEV. 344.18' DITCH 1: - 2 . 1 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 7+25ELEV. 341.87' DITCHELEV. 343.54' SHOULDERELEV. 344.02' EOPELEV. 344.22' CENTERELEV. 344.02' EOPELEV. 343.54' SHOULDERELEV. 341.87' DITCHELEV. 343.87' DITCH 1:- 2 . 1 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 7+50ELEV. 341.65' DITCHELEV. 343.32' SHOULDERELEV. 343.80' EOPELEV. 344.00' CENTERELEV. 343.80' EOPELEV. 343.32' SHOULDERELEV. 341.65' DITCHELEV. 343.65' DITCH 1: - 2 . 1 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 7+75ELEV. 341.47' DITCHELEV. 343.14' SHOULDERELEV. 343.62' EOPELEV. 343.82' CENTERELEV. 343.62' EOPELEV. 343.14' SHOULDERELEV. 341.47' DITCHELEV. 343.47' DITCH 1:- 2 . 2 1:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 8+00ELEV. 341.30' DITCHELEV. 342.96' SHOULDERELEV. 343.44' EOPELEV. 343.64' CENTERELEV. 343.44' EOPELEV. 342.96' SHOULDERELEV. 341.30' DITCH 1:- 2 . 4 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.1CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 8+25ELEV. 341.12' DITCHELEV. 342.79' SHOULDERELEV. 343.27' EOPELEV. 343.47' CENTERELEV. 343.27' EOPELEV. 342.79' SHOULDERELEV. 341.12' DITCH 1:- 2 . 6 1:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.1CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 8+50ELEV. 340.94' DITCHELEV. 342.61' SHOULDERELEV. 343.09' EOPELEV. 343.29' CENTERELEV. 343.09' EOPELEV. 342.61' SHOULDERELEV. 340.94' DITCH 1:- 2 . 8 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.1PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONKnow what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD CROSS SECTIONSC5.4 FEETSCALE 0 10 20 HORZ. FEETSCALE 0 5 10 VERT. CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 8+75ELEV. 340.76' DITCHELEV. 342.43' SHOULDERELEV. 342.91' EOPELEV. 343.11' CENTERELEV. 342.91' EOPELEV. 342.43' SHOULDERELEV. 340.76' DITCH 1:- 2 . 8 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 9+00ELEV. 340.59' DITCHELEV. 342.26' SHOULDERELEV. 342.74' EOPELEV. 342.94' CENTERELEV. 342.74' EOPELEV. 342.26' SHOULDERELEV. 340.59' DITCHELEV. 342.59' DITCH 1:- 2 . 8 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 9+25ELEV. 340.44' DITCHELEV. 342.11' SHOULDERELEV. 342.59' EOPELEV. 342.79' CENTERELEV. 342.59' EOPELEV. 342.11' SHOULDERELEV. 340.44' DITCH 1:- 2 . 7 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.1CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 9+50ELEV. 340.32' DITCHELEV. 341.98' SHOULDERELEV. 342.46' EOPELEV. 342.66' CENTERELEV. 342.46' EOPELEV. 341.98' SHOULDERELEV. 340.32' DITCH 1:- 2 . 7 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.3 CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 9+75ELEV. 340.19' DITCHELEV. 341.86' SHOULDERELEV. 342.34' EOPELEV. 342.54' CENTERELEV. 342.34' EOPELEV. 341.86' SHOULDERELEV. 340.19' DITCH 1:- 2 . 6 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.2 CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 10+00ELEV. 340.07' DITCHELEV. 341.73' SHOULDERELEV. 342.21' EOPELEV. 342.41' CENTERELEV. 342.21' EOPELEV. 341.73' SHOULDERELEV. 340.07' DITCH 1:- 2 . 5 1:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.1CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 10+25ELEV. 339.94' DITCHELEV. 341.61' SHOULDERELEV. 342.09' EOPELEV. 342.29' CENTERELEV. 342.09' EOPELEV. 341.61' SHOULDERELEV. 339.94' DITCHELEV. 341.94' DITCH 1:- 2 . 3 1:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 10+50ELEV. 339.82' DITCHELEV. 341.48' SHOULDERELEV. 341.96' EOPELEV. 342.16' CENTERELEV. 341.96' EOPELEV. 341.48' SHOULDERELEV. 339.82' DITCHELEV. 341.82' DITCH 1:- 2 . 1 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 10+75ELEV. 341.69' DITCHELEV. 339.69' DITCHELEV. 341.36' SHOULDERELEV. 341.84' EOPELEV. 342.04' CENTERELEV. 341.84' EOPELEV. 341.36' SHOULDERELEV. 339.69' DITCHELEV. 341.69' DITCH 1:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 11+00ELEV. 341.57' DITCHELEV. 339.57' DITCHELEV. 341.23' SHOULDERELEV. 341.71' EOPELEV. 341.91' CENTERELEV. 341.71' EOPELEV. 341.23' SHOULDERELEV. 339.57' DITCHELEV. 341.57' DITCH 1:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 11+25ELEV. 341.44' DITCHELEV. 339.44' DITCHELEV. 341.11' SHOULDERELEV. 341.59' EOPELEV. 341.79' CENTERELEV. 341.59' EOPELEV. 341.11' SHOULDERELEV. 339.44' DITCHELEV. 341.44' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 11+50ELEV. 341.32' DITCHELEV. 339.32' DITCHELEV. 340.98' SHOULDERELEV. 341.46' EOPELEV. 341.66' CENTERELEV. 341.46' EOPELEV. 340.98' SHOULDERELEV. 339.32' DITCHELEV. 341.32' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.01:2.0PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONKnow what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD CROSS SECTIONSC5.5 FEETSCALE 0 10 20 HORZ. FEETSCALE 0 5 10 VERT. 332 334 336 338 340 342 344 346 348 350 352 354 330 332 334 336 338 340 342 344 346 348 350 352 354 330 332 334 336 338 340 342 344 346 348 350 352 354 330 CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 11+75ELEV. 341.13' DITCHELEV. 339.13' DITCHELEV. 340.80' SHOULDERELEV. 341.28' EOPELEV. 341.48' CENTERELEV. 341.28' EOPELEV. 340.80' SHOULDERELEV. 339.13' DITCHELEV. 341.13' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 11+96.2ELEV. 340.91' DITCHELEV. 338.91' DITCHELEV. 340.58' SHOULDERELEV. 341.06' EOPELEV. 341.26' CENTERELEV. 341.06' EOPELEV. 340.58' SHOULDERELEV. 338.91' DITCHELEV. 340.91' DITCH 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 12+00ELEV. 340.86' DITCHELEV. 338.86' DITCHELEV. 340.53' SHOULDERELEV. 341.01' EOPELEV. 341.21' CENTERELEV. 341.01' EOPELEV. 340.53' SHOULDERELEV. 338.86' DITCHELEV. 340.86' DITCH 1:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 12+25ELEV. 340.56' DITCHELEV. 338.56' DITCHELEV. 340.23' SHOULDERELEV. 340.71' EOPELEV. 340.91' CENTERELEV. 340.71' EOPELEV. 340.23' SHOULDERELEV. 338.56' DITCHELEV. 340.56' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 12+50ELEV. 340.26' DITCHELEV. 338.26' DITCHELEV. 339.93' SHOULDERELEV. 340.41' EOPELEV. 340.61' CENTERELEV. 340.41' EOPELEV. 339.93' SHOULDERELEV. 338.26' DITCHELEV. 340.26' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 12+75ELEV. 339.96' DITCHELEV. 337.96' DITCHELEV. 339.63' SHOULDERELEV. 340.11' EOPELEV. 340.31' CENTERELEV. 340.11' EOPELEV. 339.63' SHOULDERELEV. 337.96' DITCHELEV. 339.96' DITCH1:-2.01:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 13+00ELEV. 339.66' DITCHELEV. 337.66' DITCHELEV. 339.33' SHOULDERELEV. 339.81' EOPELEV. 340.01' CENTERELEV. 339.81' EOPELEV. 339.33' SHOULDERELEV. 337.66' DITCHELEV. 339.66' DITCH 1: - 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 13+25ELEV. 339.36' DITCHELEV. 337.36' DITCHELEV. 339.03' SHOULDERELEV. 339.51' EOPELEV. 339.71' CENTERELEV. 339.51' EOPELEV. 339.03' SHOULDERELEV. 337.36' DITCHELEV. 339.36' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 13+50ELEV. 339.06' DITCHELEV. 337.06' DITCHELEV. 338.73' SHOULDERELEV. 339.21' EOPELEV. 339.41' CENTERELEV. 339.21' EOPELEV. 338.73' SHOULDERELEV. 337.06' DITCHELEV. 339.06' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 13+75ELEV. 338.76' DITCHELEV. 336.76' DITCHELEV. 338.43' SHOULDERELEV. 338.91' EOPELEV. 339.11' CENTERELEV. 338.91' EOPELEV. 338.43' SHOULDERELEV. 336.76' DITCHELEV. 338.76' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 14+00ELEV. 338.46' DITCHELEV. 336.46' DITCHELEV. 338.13' SHOULDERELEV. 338.61' EOPELEV. 338.81' CENTERELEV. 338.61' EOPELEV. 338.13' SHOULDERELEV. 336.46' DITCHELEV. 338.46' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 14+25ELEV. 338.16' DITCHELEV. 336.16' DITCHELEV. 337.83' SHOULDERELEV. 338.31' EOPELEV. 338.51' CENTERELEV. 338.31' EOPELEV. 337.83' SHOULDERELEV. 336.16' DITCHELEV. 338.16' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONKnow what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD CROSS SECTIONSC5.6 FEETSCALE 0 10 20 HORZ. FEETSCALE 0 5 10 VERT. CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 14+50ELEV. 337.88' DITCHELEV. 335.88' DITCHELEV. 337.55' SHOULDERELEV. 338.03' EOPELEV. 338.23' CENTERELEV. 338.03' EOPELEV. 337.55' SHOULDERELEV. 335.88' DITCHELEV. 337.88' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 14+75ELEV. 337.69' DITCHELEV. 335.69' DITCHELEV. 337.36' SHOULDERELEV. 337.84' EOPELEV. 338.04' CENTERELEV. 337.84' EOPELEV. 337.36' SHOULDERELEV. 335.69' DITCHELEV. 337.69' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 15+00ELEV. 337.56' DITCHELEV. 335.56' DITCHELEV. 337.23' SHOULDERELEV. 337.71' EOPELEV. 337.91' CENTERELEV. 337.71' EOPELEV. 337.23' SHOULDERELEV. 335.56' DITCHELEV. 337.56' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 15+25ELEV. 337.44' DITCHELEV. 335.44' DITCHELEV. 337.10' SHOULDERELEV. 337.58' EOPELEV. 337.78' CENTERELEV. 337.58' EOPELEV. 337.10' SHOULDERELEV. 335.44' DITCHELEV. 337.44' DITCH 1: - 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 15+50ELEV. 337.31' DITCHELEV. 335.31' DITCHELEV. 336.98' SHOULDERELEV. 337.46' EOPELEV. 337.66' CENTERELEV. 337.46' EOPELEV. 336.98' SHOULDERELEV. 335.31' DITCHELEV. 337.31' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 15+75ELEV. 337.19' DITCHELEV. 335.19' DITCHELEV. 336.85' SHOULDERELEV. 337.33' EOPELEV. 337.53' CENTERELEV. 337.33' EOPELEV. 336.85' SHOULDERELEV. 335.19' DITCHELEV. 337.19' DITCH 1: - 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 16+00ELEV. 337.05' DITCHELEV. 335.05' DITCHELEV. 336.72' SHOULDERELEV. 337.20' EOPELEV. 337.40' CENTERELEV. 337.20' EOPELEV. 336.72' SHOULDERELEV. 335.05' DITCHELEV. 337.05' DITCH 1: - 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 16+25ELEV. 336.87' DITCHELEV. 334.87' DITCHELEV. 336.53' SHOULDERELEV. 337.01' EOPELEV. 337.21' CENTERELEV. 337.01' EOPELEV. 336.53' SHOULDERELEV. 334.87' DITCHELEV. 336.87' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 16+38.88ELEV. 336.73' DITCHELEV. 334.73' DITCHELEV. 336.40' SHOULDERELEV. 336.88' EOPELEV. 337.08' CENTERELEV. 336.88' EOPELEV. 336.40' SHOULDERELEV. 334.73' DITCHELEV. 336.73' DITCH 1:- 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 16+50ELEV. 336.61' DITCHELEV. 334.61' DITCHELEV. 336.28' SHOULDERELEV. 336.76' EOPELEV. 336.96' CENTERELEV. 336.76' EOPELEV. 336.28' SHOULDERELEV. 334.61' DITCHELEV. 336.61' DITCH1:-2.01:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 16+75ELEV. 336.35' DITCHELEV. 334.35' DITCHELEV. 336.02' SHOULDERELEV. 336.50' EOPELEV. 336.70' CENTERELEV. 336.50' EOPELEV. 336.02' SHOULDERELEV. 334.35' DITCHELEV. 336.35' DITCH 1:- 2 . 0 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 17+00ELEV. 336.09' DITCHELEV. 334.09' DITCHELEV. 335.76' SHOULDERELEV. 336.24' EOPELEV. 336.44' CENTERELEV. 336.24' EOPELEV. 335.76' SHOULDERELEV. 334.09' DITCHELEV. 336.09' DITCH 1: - 2 . 0 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONKnow what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD CROSS SECTIONSC5.7 FEETSCALE 0 10 20 HORZ. FEETSCALE 0 5 10 VERT. CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 17+25ELEV. 335.83' DITCHELEV. 333.83' DITCHELEV. 335.50' SHOULDERELEV. 335.98' EOPELEV. 336.18' CENTERELEV. 335.98' EOPELEV. 335.50' SHOULDERELEV. 333.83' DITCHELEV. 335.83' DITCH 1: - 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 17+50ELEV. 335.57' DITCHELEV. 333.57' DITCHELEV. 335.23' SHOULDERELEV. 335.71' EOPELEV. 335.91' CENTERELEV. 335.71' EOPELEV. 335.23' SHOULDERELEV. 333.57' DITCHELEV. 335.57' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 17+75ELEV. 335.31' DITCHELEV. 333.31' DITCHELEV. 334.97' SHOULDERELEV. 335.45' EOPELEV. 335.65' CENTERELEV. 335.45' EOPELEV. 334.97' SHOULDERELEV. 333.31' DITCHELEV. 335.31' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 18+00ELEV. 335.04' DITCHELEV. 333.04' DITCHELEV. 334.71' SHOULDERELEV. 335.19' EOPELEV. 335.39' CENTERELEV. 335.19' EOPELEV. 334.71' SHOULDERELEV. 333.04' DITCHELEV. 335.04' DITCH 1: - 2 . 0 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 18+25ELEV. 334.78' DITCHELEV. 332.78' DITCHELEV. 334.45' SHOULDERELEV. 334.93' EOPELEV. 335.13' CENTERELEV. 334.93' EOPELEV. 334.45' SHOULDERELEV. 332.78' DITCHELEV. 334.78' DITCH 1: - 2 . 0 1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 18+50ELEV. 334.52' DITCHELEV. 332.52' DITCHELEV. 334.19' SHOULDERELEV. 334.67' EOPELEV. 334.87' CENTERELEV. 334.67' EOPELEV. 334.19' SHOULDERELEV. 332.52' DITCHELEV. 334.52' DITCH1:-2.01:- 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.01:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 18+75ELEV. 334.26' DITCHELEV. 332.26' DITCHELEV. 333.93' SHOULDERELEV. 334.41' EOPELEV. 334.61' CENTERELEV. 334.41' EOPELEV. 333.93' SHOULDERELEV. 332.26' DITCHELEV. 334.26' DITCH1:-2.01:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 19+00ELEV. 334.00' DITCHELEV. 332.00' DITCHELEV. 333.66' SHOULDERELEV. 334.14' EOPELEV. 334.34' CENTERELEV. 334.14' EOPELEV. 333.66' SHOULDERELEV. 332.00' DITCHELEV. 334.00' DITCH 1:- 2 . 0 1: - 2 . 0 1:3.0 8.0%2.0%-2.0%-8.0% 1:-3 . 0 1:2.0CL 30252015105-5-10-15-20-25-30 332332 334334 336336 338338 340340 342342 344344 346346 348348 350350 352352 354354 330 330 19+25ELEV. 333.74' DITCHELEV. 331.74' DITCHELEV. 333.40' SHOULDERELEV. 333.88' EOPELEV. 334.08' CENTERELEV. 333.88' EOPELEV. 333.40' SHOULDERELEV. 331.74' DITCHELEV. 333.74' DITCH1:-2.01:3.0 8.0%2.0%-2.0%-8.0% 1:- 3 . 0 1:2.0PRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONKnow what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONROAD CROSS SECTIONSC5.8 FEETSCALE 0 10 20 HORZ. FEETSCALE 0 5 10 VERT. NOT TO SCALE SITE DETAILSC7.0 TYPICAL LOCAL RESIDENTIAL ROAD CROSS SECTION Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONDESCRIPTIONSYMBOL PAVEMENT SCHEDULE C1 NOTE: 1. PROVIDE A SMOOTH TRANSITION TO EXISTING PAVEMENT. 2. ALL MATERIAL AND CONSTRUCTION METHODS SHOULD CONFORM TO E1 THE 2018 EDITION OF THE NCDOT STANDARD SPECIFICATIONS. T 3. IF WET SOIL CONDITIONS ARE ENCOUNTERED, CONTRACTOR SHALL UNDERCUT AND REPLACE WITH STRUCTURAL FILL AND / OR USE OF STRUCTURAL FABRIC ALL SUBGRADE SHALL MEET NCDOT STANDARD MODIFIED PROCTOR DENSITY PROPOSED 6" ABC COMPACTED TO 100 PERCENT. PREPARED SUBGRADE: COMPACTED TO A MINIMUM OF 98% OF THE SOIL'S MODIFIED PROCTOR DENSITY ( ASTM 698) PLACE IN 6: LIFTS. - SEE NOTE 3 PROVIDE TEST RESULTS FOR SUBGRADE COMPACTION. PROPOSED 2" ASPHALT SURFACE COURSE TYPE S9.5B WHERE REQUIRED BY GEOTECHNICAL ENGINEER. TYPICAL CUL-DE-SAC DETAIL NOT TO SCALE 3:1 2.0% 3:1R/WR/WC/L10'10' 6'SHOULDER 5' DITCH 6' SHOULDER 50' ROW 2.0%8.0%8.0% SLOPER/WC/L20' PAVEMENT WIDTH C1 E1 T 5' DITCH R45'R35' 1:1 6"1:1SHOULDER ASPHALT CONCRETEBASE COURSE SURFACE COURSE 20' EOP R25' R17' 50' ROW SECTION A-AC/L6'35'5' 4' SLOPE AS REQUIRED 8% 3:1 SLOPE 328 329 331 330 323 315 316 317 319 320 321 324 325 327 314 322 326 318 OPEN SPACE:170,109 SF3.91 AC314 315316 320 319 318 317 314 315 316 320 319318 317 328 327 326 325 324 323 322 329 330 329328327326325324323330322314 315316 320319 318 317 320 319 318 321 314 320 319 318 317 316 315 321 314 315 316 320319318317 321 321.50321.50321.500+000+200+400+600+801+001+20 1+40 1+60 1+80 2+00 2+20 2+40 2+602+803+003+203+403+603+803+99.780+000+200+400+600+801+001+201+401+601+802+002+13.50SECTION B-B SECTION A-A0+00 0+50 1+00 1+50 2+00 304 306 308 310 312 314 316 318 320 322 324 326 328 330 332 304 306 308 310 312 314 316 318 320 322 324 326 328 330 332 EXISTING GROUND NORMAL POOL EL: 317.00'3 1 6" CLAY SOIL LINER MAIN POOL 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 304 306 308 310 312 314 316 318 320 322 324 326 328 330 332 334 336 304 306 308 310 312 314 316 318 320 322 324 326 328 330 332 334 336 EXISTING GROUND NORMAL POOL EL: 317.00' TOP OF BASIN: 321.50 TOP OF BASIN: 321.50 3 1 5 1 3 1 5 1 5 1 3 1 10.0' 6" CLAY SOIL LINER MAIN POOL DOUBLE GABION BASKET WEIR FOR THE FIRST 3 FEET. TOP OF GABION EL = 318.50' BOTTOM OF PONDEL: 314.00' SEDIMENT CLEANOUT: 315.00' 10 YR EL: 318.72' 25 YR EL: 319.25 50 YR EL: 319.59' 100 YR EL: 320.05'STORMWATERMANAGEMENT DETAILSC8.0 DRAW DOWN ORIFICE DETAIL RISER PERMANENT POOL OUTLET 4" PVC TEE 4" PVC PLUG SCREW TYPE TEMPORARY POOL EL. 162.00' NORMAL POOL EL. 161.00' 2" DRAW DOWN ORIFICE TEMPORARY POOL 12"4" PVC PIPE STUBBED INTO OUTLET RISER BMP ELEMENT THE ENTIRE BMP POTENTIAL PROBLEM TRASH/DEBRIS IS PRESENT. HOW TO REMEDIATE THE PROBLEM REMOVE THE TRASH/DEBRIS. INSPECTION AND MAINTENANCE PROVISIONS AREAS OF BARE SOIL AND/OR EROSIVE GULLIES HAVE FORMED. ESTABLISHED. PROVIDE LIME AND A ONE- GROUND COVER AND WATER UNTIL IT IS REMOVE THE GULLY, AND THEN PLANT A REGRADE THE SOIL IF NECESSARY TO TIME FERTILIZER APPLICATION. THE PERIMETER OF THE WET DETENTION BASIN THE PIPE IS CLOGGED.THE INLET DEVICE: PIPE OR SWALE UNCLOG THE PIPE. DISPOSE OF THE SEDIMENT OFF-SITE. EROSION IS OCCURRING IN THE SWALE. TURF MATTING OR RIPRAP TO AVOIDCONTROL DEVICES SUCH AS REINFORCED SMOOTH IT OVER AND PROVIDE EROSION REGRADE THE SWALE IF NECESSARY TO FUTURE PROBLEMS WITH EROSION. THE FOREBAY SEDIMENT HAS ACCUMULATED TO A DEPTH GREATER THAN THE ORIGINAL DESIGN DEPTH FOR POSSIBLE. REMOVE THE SEDIMENT AND SEDIMENT AND REMEDY THE PROBLEM IF SEARCH FOR THE SOURCE OF THE EROSION HAS OCCURRED. THE PLANTS RATHER THAN SPRAYING. HAND. IF PESTICIDE IS USED, WIPE IT ON REMOVE THE WEEDS, PREFERABLY BYWEEDS ARE PRESENT. THE VEGETATED SHELF PLANTS. PROVIDE A ONE-TIME FERTILIZER ETC. REMEDY THE PROBLEM AND REPLACE PROBLEM: SOILS, HYDROLOGY, DISEASE,DETERMINE THE SOURCE OF THE APPLICATION TO ESTABLISH THE GROUND COVER IF A SOIL TEST INDICATES IT IS NECESSARY. BEST PROFESSIONAL PRACTICES SHOW THAT PRUNING IS NEEDED THE MAIN TREATMENTAREA DISPOSE OF IT IN A LOCATION WHERE IT POSSIBLE. REMOVE THE SEDIMENT AND SEDIMENT AND REMEDY THE PROBLEM IFSEARCH FOR THE SOURCE OF THE WILL NOT CAUSE IMPACTS TO STREAMS OR THE BMP. SEDIMENT HAS ACCUMULATED TOA DEPTH GREATER THAT THE AND CONTROL THE ALGAL GROWTH.CONSULT A PROFESSIONAL TO REMOVEALGAL GROWTH COVERS OVER50% OF THE AREA. TOO LONG.VEGETATION IS TOO SHORT OR MAINTAIN VEGETATION AT A HEIGHT OFAPPROXIMATELY SIX INCHES. OTHERWISE DAMAGED. THE PIPE IS CRACKED OR REPLACE THE PIPE. THE BMP. WILL NOT CAUSE IMPACTS TO STREAMS OR DISPOSE OF IT IN A LOCATION WHERE ITSEDIMENT STORAGE. EROSION PROBLEMS. RIPRAP IF NEEDED TO PREVENT FUTURESUCH AS REINFORCED TURF MATTING OR PROVIDE ADDITIONAL EROSION PROTECTION TO MAINTAIN OPTIMAL PLANT HEALTH. PRACTICES. PRUNE ACCORDING TO BEST PROFESSIONAL PLANTS ARE DEAD, DISEADED ORDYING. THE PLANTS RATHER THAN SPRAYING. HAND. IF PESTICIDE IS USED, WIPE IT ON REMOVE THE WEEDS, PREFERABLY BYWEEDS ARE PRESENT. ORIGINAL DESIGN SEDIMENT STORAGE DEPTH. WITH PESTICIDE (DO NOT SPRAY). REMOVE THE PLANTS BY WIPING THEMCATTAILS, PHRAGMITES OR OTHER INVASIVE PLANTS COVER 50% OF THE BASIN SURFACE. THE EMBANKMENT REMOVE SHRUBS IMMEDIATELY.SHRUBS HAVE STARTED TO GROW ON THE EMBANKMENT. BEAVERS.CONSULT A PROFESSIONAL TO REMOVE USE TRAPS TO REMOVE MUSKRATS ANDEVIDENCE OF MUSKRAT OR BEAVER ACTIVITY IS PRESENT. REMOVE THE TREE. CONSULT A DAM SFETY SPECIALIST TOA TREE HAS STARTED TO GROW ON THE EMBANKMENT. MAKE ALL NEEDED REPAIRS.AN ANNUAL INSPECTION BY AN APPROPRIATE PROFESSIONAL SHOWS THAT THE EMBANKMENT NEEDS REPAIR. OF THE SEDIMENT OFF-SITE.CLEAN OUT THE OUTLET DEVICE. DISPOSECLOGGING HAS OCCURRED.THE OUTLET DEVICE THE OUTLET DEVICE IS DAMAGED. REPAIR OR REPLACE THE OUTLET DEVICE. THE RECEIVING WATER THE 401 OVERSIGHT UNIT, 919-733-1786. QUALITY WASHINGTON REGIONAL OFFICE, OR CONTACT THE NC DIVISION OF WATER DAMAGE HAVE OCCURRED AT THE EROSION OR OTHER SIGNS OF OUTLET. WET POND PLAN VIEW SCALE: 1" = 30' WET POND - SECTION A-A CONSTRUCTION SEQUENCE FOR WET DETENTION POND: 1. INSTALL EROSION CONTROLS 2. CONSTRUCT DAM BASE AND AREAS BELOW THE NORMAL POOL. CONSTRUCTION TO BE PERFORMED UNDER THE INSPECTION OF THE GEOTECHNICAL ENGINEER. SEED UPON COMPLETION 3. INSTALL OUTLET PIPE, RIPRAP APRON AND STONE FILTER RING. 4. CONSTRUCT OUTLET STRUCTURE, INSTALL TEMPORARY SKIMMER. 5. UPON COMPLETION AND STABILIZATION OF UPSTREAM DEVELOPMENT, REMOVE SKIMMER, INSTALL PERMANENT ORIFICE DRAWDOWN DEVICE AND SEED UPON COMPLETION. NOTE: STORMWATER PONDS ARE TO BE CONSTRUCTED FOR USE AS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION. ONCE CONSTRUCTION IS COMPLETED THE TEMPORARY SEDIMENT BASIN IS TO BE CLEANED UP AND SHAPED PRIOR TO BE USED AS A STORMWATER POND. NOTE: 1. CONTRACTOR TO PROVIDE A PEAKED ROOF STRUCTURE TRASH RACK BY PLASTIC SOLUTIONS INC. (877-87775727) OR EQUIVALENT. 6" x 6" MAXIMUM GRATE OPENING 2. PROVIDE STEPS IN ALL DRAINAGE STRUCTURES DEEPER THAN 54". LOCATE STEPS WITHIN REASONABLE PROXIMITY TO ACCESS POINT (MANHOLE OR GRATE OPENING) WITHOUT INTERFERING WITH PIPE ORIENTATIONS. TRASH RACK SEE MANUFACTURERS SPECIFICATIONS FOR DETAILS 4" PVC PIPE FOR DRAW DOWN ORIFICE INV = 317.00' ~ WET POND ~ TOP OF RIM = 318.50' 15" RCP INVERT = 315.50' TRASH RACK BY PLASTIC SOLUTIONS INC. OR EQUIVALENT 2'-2" X 3.0' PRECAST BOX 4' MIN KEY 1 1 3' MIN. CUTOFF TRENCH APPROXIMATE SIZE EXCAVATE AND BACKFILL WITH COMPACTED FILL AS DIRECTED BY GEOTECHNICAL ENGINEER SCALE: N.T.S. CUTOFF TRENCH - OUTFALL DETAIL 6.5' X 6.5' CONC. ANTI- SEEPAGE COLLAR SEE DETAIL FILL CONCRETE TO ELEVATION 317.00' ELEV. = 314.00' 3' X 4' CONC. BASE REINFORCED WITH #4 BARS AT 12" O.C. TOP AND BOTTOM OF EACH DIRECTION. PROVIDE 3" MIN CLEARANCE BETWEEN EDGE OF CONCRETE AND STEEL REINFORCING. SCALE: N.T.S. TYPICAL VEGETATIVE SHELF DETAIL POND NORMAL POOL SHALLOW LAND ZONE HERBACEOUS PLANTS 6 1 WATER LEVEL LOW POINT PUMPFLOW FL O W SCALE: N.T.S. INFILTRATION BASIN DEWATERING NOTES: 1) PRIOR TO INSTALLATION, MANUFACTURER SPECIFICATIONS OF FILTER MEDIA SHALL BE REVIEWED TO ENSURE THAT DISCHARGE FROM FILTER MEDIA SHALL MEET OR EXCEED THE PROVISIONS OF THE CLEAN WATER ACT. 2) ENSURE THAT PUMP PRESSURE DOES NOT EXCEED FILTER MEDIA PRESSURE RATING. 3) FILTER MEDIA MAY BE, BUT NOT LIMITED TO, SAND MEDIA FILTRATION PRACTICES. 4) PUMP STRAINER SHALL NOT BE IN CONTACT WITH BOTTOM OF POND. SCALE: N.T.S. CONCRETE ANTI- SEEPAGE COLLAR 6.5' 3.25' 3.25' 6.5' 12" #4 REBAR @12" OC IN FRONT & REAR FACE OF COLLAR. REBAR TO HAVE 3" MIN. CONC. COVER FROM EDGE OF FACE OF COLLAR NOTES: 1) ALL CONCRETE TO BE 3000 PSI NON-FLY ASH 2) APPLY 1/2" THICK WRAP OF ASPHALTIC CEMENT AROUND DISCHARGE PIPE 6" BEYOND PLANNED SEEPAGE COLLAR ON BOTH SIDES 3) APPLY ADDITIONAL ASPHALTIC CEMENT AT PIPE/SEEPAGE COLLAR INTERFACE ON UPSTREAM FACES 4) TO BE FIELD INSPECTED BY GEOTECHNICAL ENGINEER. ASPHALTIC CEMENT TO MEET OR EXCEED FEDERAL SPECIFICATION SS-153 TYP1: ASTM-D-2822-75 TYPE 1. SCALE: N.T.S. STORM WATER MANAGEMENT NOTES: 1. THE DEVELOPER OR HIS AGENT SHALL CONTACT THE DESIGN ENGINEER WHEN THE BEST MANAGEMENT PRACTICES ARE CONSTRUCTED AND ABOUT TO BECOME OPERATIONAL SO THAT A FINAL INSPECTION CAN BE PERFORMED TO DETERMINE COMPLIANCE WITH THE APPROVED PLAN. 2. ANNUAL MAINTENANCE INSPECTION AND REPORT REQUIRED. THE OWNER OF A PERMITTED STRUCTURAL STORM WATER BMP SHALL ANNUALLY SUBMIT A MAINTENANCE AND INSPECTION REPORT FOR EACH BMP TO THE STORM WATER ADMINISTRATOR. ANNUAL INSPECTIONS SHALL BEGIN WITHIN ONE YEAR OF THE RECORDATION OF ANY DEED(S) SHOWING STORM WATER BMPS. 3. UPON COMPLETION OF THE PROJECT, THE ENGINEER OF RECORD SHALL CERTIFY THAT THE COMPLETED PROJECT IS IN ACCORDANCE WITH THE APPROVED STORM WATER MANAGEMENT PLANS AND DESIGNS. 4. A FINAL INSPECTION OF THE SITE AND STORM WATER BMP SHALL BE SCHEDULED WITH AND COMPLETED BY THE PROJECT ENGINEER. 5. NCDEQ AND THEIR ASSIGNS HAVE RIGHT TO ACCESS THE STORM WATER CONTROLS FOR INSPECTIONS OR MAINTENANCE AS NECESSARY. 6. THE PROPERTY OWNER IS RESPONSIBLE FOR MAINTAINING THE STORM WATER CONTROLS ACCORDING TO THE APPROVED MAINTENANCE PLAN AND DIRECTION OF NCDEQ. BMP LANDSCAPE NOTES: 1. THE BMP LANDSCAPING SHALL BE IN COMPLIANCE WITH THE NCDEQ BMP REQUIREMENTS. 2. LANDSCAPE CONTRACTOR SHALL PROVIDE A TWO-YEAR WARRANTY PERIOD. ALL PLANTS THAT DO NOT SURVIVE MUST BE REPLACED. 3. AT THE END OF THE FIRST YEAR AND AT THE END OF THE TWO-YEAR WARRANTY PERIOD, ALL PLANTS THAT DO NOT SURVIVE MUST BE REPLACED. 4. ESTABLISHMENT PROCEDURES SUCH AS CONTROL OF INVASIVE WEEDS, ANIMAL AND VANDAL DAMAGE, MULCHING, AND WATERING SHALL BE IMPLEMENTED TO THE EXTEND NEEDED TO ENSURE PLANT SURVIVAL. 5. SOD WITHIN BMP AND SURROUNDING AREAS TO BE CENTIPEDE GRASS. 6. GRASS OR WILDFLOWER SEED MUST BE APPLIED AT THE RATES SPECIFIED BY THE SUPPLIERS. IF PLANT ESTABLISHMENT CANNOT BE ACHIEVED WITH SEEDING BY THE TIME OF SUBSTANTIAL COMPLETION OF THE STORM WATER FACILITY PORTION OF THE PROJECT, THEN THE CONTRACTOR SHALL PLANT THE AREA WITH WILDFLOWER SOD, PLUGS, CONTAINER PLANTS, OR OTHER MEANS TO COMPLETE THE SPECIFIED PLANTING AND PROJECT AGAINST EROSION BEFORE WATER IS ALLOWED TO ENTER THE STORM WATER BMP FACILITY. 7. ALL MATERIALS SHALL BE ACQUIRED FROM AN APPROVED NCDEQ PLANT VENDOR. PLANT MATERIAL SHOULD BE PURCHASED FROM A LOCAL SOURCE TO ENSURE SURVIVABILITY. 8. IMMEDIATELY AFTER THE WET DETENTION BASIN IS ESTABLISHED, THE PLANTS ON THE VEGETATED SHELF AND PERIMETER OF THE BASIN SHOULD BE WATERED TWICE WEEKLY IF NEEDED UNTIL THE PLANTS BECOME ESTABLISHED (COMMONLY SIX WEEKS). 9. NO PORTION OF THE WET DETENTION POND SHOULD BE FERTILIZED AFTER THE FIRST INITIAL FERTILIZATION THAT IS REQUIRED TO ESTABLISH THE PLANTS ON THE VEGETATED SHELF. 10. BMP PLANT SUBSTITUTIONS ARE NOT PERMITTED. 11. ONLY NON-CLUMPING TURF GRASSES SHALL BE USED. TREES AND WOODY SHRUBS SHALL NOT BE ALLOWED ON THE DAM OR TOP OF SLOPE AREA/10' MAINTENANCE AREA OF THE BMP. BMP MAINTENANCE: Important operation and maintenance procedures: 1. Immediately after the wet pond is established, the plants on thevegetated shelf and perimeter of the basin will be watered twiceweekly if needed, until the plants become established(commonly six weeks).2. No portion of the wet pond will be fertilized after the first initialfertilization that is required to establish the plants on thevegetated shelf.3. Stable ground cover will be maintained in the drainage area toreduce the sediment load to the wet pond.4. If the pond must be drained for an emergency or to performmaintenance, the flushing of sediment through the emergencydrain will be minimized as much as possible.5. Once a year, a dam safety expert should inspect theembankment.6. The measuring device used to determine the sediment elevationshall be such that it will give an accurate depth reading and notreadily penetrate into accumulated sediments. After the wet pond is established, it should be inspected quarterly andwithin 24 hours after every storm event greater than 1.0 inches (or 1.5inches if in a Coastal County).. Records of operation and maintenancewill be kept in a known set location and shall be available uponrequest.Inspection activities shall be performed as follows. Any problems thatare found shall be repaired immediately. Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONFEETSCALE 0 30 60 HORZ. WET POND - SECTION B-B FEETSCALE 0 50 100 HORZ. FEETSCALE 0 5 10 VERT. 2'-2" X 3' PRECAST CONCRETE RISER ELEV = 318.50' 4" DIA. ORIFICE ELEV = 317.00' TOP OF DAM ELEV = 321.50'GABION BASKET WEIR TOP ELEV = 318.50' GABION BASKET WEIR TOP ELEV = 318.50' VEGETATIVE SHELF PLANTINGS: AREA OF VEGETATIVE SHELF: 2,846 SF MIN. PLANTS REQUIRED: 712 PLANT TYPE: SCIENTIFIC NAME:COMMON NAME:QUANTITY: NURSERY CONTAINER: SPACING: PLANTING SEASON: EUPATORIADELPHUS MACULATUS SPOTTED TRUMPETWEED 238 PEAT POT 6' O.C. SPRING/SUMMER EUPATORIUM PURPUREUM JOE-PYE WEED 238 PEAT POT 6' O.C. SPRING/SUMMER RHYNCHOSPORA COLORATA STARRUSH WHITETOP 238 PEAT POT 6' O.C. SPRING/SUMMER 48 LF 15" RCP PIPE ANTI-SEEP COLLAR - SEE DETAIL RIP RAP OUTLET APRON APRON WIDTH AT PIPE OUTLET: 4' APRON LENGTH: 24' APRON WIDTH AT SILT FENCE OUTLET: 18' APRON THICKNESS: 1.5' THICK CLASS B RIP RAP ON MIRIFI FILTER FABRIC. EMBED RIP RAP 1.5' INTO GROUND SO THAT RUNOFF FLOWS ON TOP OF THE RIP RAP SURFACE. INVERT OUT = 315.00' 15" RCP INV OUT = 315.00' 1234567891011 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 MARKS ROAD - NCSR 111160' PUBLIC ROW3143153163203193 18317 31 4 315 3163 2 0 319318317328327326325324323322329330329328327326325324323 330322314315316320 3 1 931 8 3 17 3203 19318 321314 3203 19318317316315 321 314 3153163203193183 1 7321321. 5 0 321.50 321.50 EXISTING 6" PVC WMCEDAR POINTE DRIVE 50' PUBLIC ROW TIE N 79°41'20" W 57.20' 208.31'S 82°19'50" E S 30°56'18" W 65.84'S 07°04'54" W 207.84'31.60'L2L3L4139.20'238.64' 335.78' 78.59' 128.17' 200.95' 144.15'N 20°03'58" W 80.29'N 07°24 '59 " W 44.86 'N 19 °13 '59 " W 169 .84 ' N 07°24'59" W 60.24' N 71° 3 6' 4 9" E 6 4 9. 8 6' S 86°20'11" E 8 8 7 . 6 4 ' T O T A L S 79°41'20" E 380.74'S 79°41'20" E 192.22' S 78°02'59" E 218.26' N 78°02'59" W 262.17'S 33°33'43" W 274.43'N 76°34'13" W 409.44' TOTAL N 78°09'28" W 849.44'S 17°44'15" W 259.41' TOTALN 78°12'14" W 884.55' HMS KI D S I N C DEED B O O K 4 0 9 3, P A G E 9 6 9574- 0 2 - 4 0 6 3 SHERI T. HARDISON, ET AL DEED BOOK 4164, PAGE 348 PLAT BOOK 2003, PAGE 559 PIN: 9574-21-6448 SHERI T. HARDISON, ET AL DEED BOOK 4164, PAGE 348 PLAT BOOK 2003, PAGE 559 PIN: 9574-21-2577 SHERI T. HARDISON, ET AL DEED BOOK 4164, PAGE 348 PLAT BOOK 2003, PAGE 559 9574-21-0623PIEDRA JORGE LUIS & GARCIA VERONICADEED BOOK 3423, PAGE 4399574-11-8773CLARK ANGIE RENEE JT W/ROS & CLARK MICHAEL L JR JT W/ROSDEED BOOK 3427, PAGE 9709574-11-7773HERNANDEZ ARMANDO GARCIA & CARBAJAL CATALINA OLASCOAGADEED BOOK 3779, PAGE 7599574-11-6764FRIEND ANDREA JOSETTEDEED BOOK 3251, PAGE 6289574-11-5754JARAMILLO-RUVALCABE JOSE DEJESUSDEED BOOK 3927, PAGE 00019574-11-4735RUSSELL SKYLER MASONDEED BOOK 3864, PAGE 8139574-11-2785LABBE S A M A NT H A DEED B O OK 4 1 3 0, P A G E 1 0 3 957 4- 1 1- 1 7 3 9 JANSEN JEREMIAH D & JANSEN MICHELLE A DEED BOOK 3241, PAGE 605 9574-10-6982 HMS KIDS INC DEED BOOK 4 0 9 3 , P A G E 9 6 9564-80-48 3 9 SMITH ELI EVERETT DEED BOOK 4111, PAGE 182 9574-10-2850 EQUITY CAPITAL UNITED, LLC DEED BOOK 2871, PAGE 709 PLAT CABINET F, SLIDE 320-D PIN: 9574-20-1859.000 EQUITY CAPIT AL U NITE D, LL C DEED B O OK 2 8 5 1, P A GE 4 1 5 PLAT C A BI NET F, SLI DE 3 2 0- D PIN: 9 5 7 4- 2 0- 3 8 4 5. 0 0 0 RED MAPLE (TYP OF ALL ) 15' LANDSCAPE BUFFER (TYP OF ALL)NORTHLANDSCAPE PLAN AND DETAILL 1.0 NOTE: 1. CONTRACTOR TO REGRADE, SOD OR HYDROSEED, AND STRAW MULCH ALL AREAS DISTURBED AS A RESULT OF HIS/HER WORK. 2. UPRIGHT STAKES TO BE USED ON TREES UP TO 12' IN HEIGHT. LARGER TREES MUST BE GUYED. 3. 1/8 OF ROOT BALL TO BE ABOVE FINISHED GRADE. 4. DO NOT COVER CROWN OF ROOT BALL EVERGREEN TREES WHICH ARE TIGHTLY SPACED SHALL BETIED TOGETHER IN ONE CONTINUOUS BED. (CONTRACTOR TO INCLUDE THIS MULCHING IN HIS/HER BID) 5. TREES WHICH ARE LOCATED WITHIN 4 FEET OF AN ADJACENT SHRUB BED SHALL HAVE THEIRMULCHED AREA CONNECTED WITH THE MULCHED BED OF THE SHRUBS. 6. PRUNE AND REMOVE BROKEN OR DEAD LIMBS/BRANCHES FROM TREES AND SHRUBS AFTERPLANTING. RETAIN NATURAL SHAPE OF PLANT. NOTE: 1. BEDS TO HAVE SMOOTHLY CONTOURED AND CLEANLY DEFINED EDGES. BEDS SHALL CURVILINEAR EXCEPT AS NOTED ON PLAN. 2. PROPOSED BEDS MUST BE LAID OUT ON SITE AND APPROVED BY OWNER, IF REQUESTED BY OWNER. 3. REMOVE TOP 1/3 OF ALL BURLAP FABRIC AROUND ROOT BALL. 4. COMPLETELY REMOVE ALL STRINGS, RIBBONS, AND TABS FROM THE PLANT. 5. SCARIFY ROOTS ON POT BOUND PLANTS. 6. PLANT SPACING VARIES - (SEE PLAN) 7. ALL SHRUBS TO BE PLANTED IN MULCHED BEDS.8. PRUNE ALL BROKEN, DISEASED, AND WEAK BRANCHES. 9. ALL SHRUB BEDS TO BE COMPLETELY EXCAVATED OF ALL EXISTING SOIL TO REQUIRED DEPTH AND BACKFILLED WITH REQUIRED SOILMIX. 10. SOIL MIX: 2/3 TOPSOIL & 1/3 ORGANIC MATTER. 11. TOP DRESS BED WITH 10-6-4 FERTILIZER AT THE RATE OF 5 LBS. PER 100 S.F. OF BED AREA. GENERAL NOTES: 1.1 THIS PLAN IS FOR LANDSCAPE PURPOSES ONLY. LANDSCAPE PLAN PROVIDED IS FOR MINIMUM COMPLIANCE WITH HARNETT COUTY UDO AND SHOULD NOT BE CONSIDERED AN ENHANCED LANDSCAPE PLAN. CONSULT WITH A REGISTERED LANDSCAPE ARCHITECT FOR SPECIFIC PLANTING RECOMMENDATIONS. 1.2 UNDERGROUND UTILITIES HAVE NOT BEEN VERIFIED BY THE OWNER, LANDSCAPE ARCHITECT, OR THEIR REPRESENTATIVES. PLEASE CALL BEFORE YOU DIG. 1.3 THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT RESULT FROM THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY UNDERGROUND UTILITIES TO REMAIN. 1.4 THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO ENSURE THAT THE NEW WORK SHALL FIT INTO THE EXISTING SITE IN THE MANNER INTENDED AND AS SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO PERFORMING ANY WORK IN THE AREA INVOLVING DISCREPANCIES. NOTIFICATION SHALL BE MADE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATING TO THE AREA. 1.5 ALL WORK SHALL MEET OR EXCEED THE REQUIREMENTS OF ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES AND REQUIREMENTS. 1.6 IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PERFORM ALL WORK IN A MANNER THAT PROTECTS COMPLETED WORK BY OTHERS, SUCH AS CURBS, UTILITIES, STORM DRAINAGE, FENCES, DRIVEWAY APRONS, DRIVES, VEGETATION, ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF SATISFACTORY REPAIR OF ALL DAMAGES IN KIND RESULTING FROM HIS/HER FAILURE TO COMPLY. 1.7 THE CONTRACTOR IS TO VERIFY ALL QUANTITIES SHOWN ON THE PLAN AND IN THE PLANT SCHEDULE. IF DISCREPANCIES OCCUR, THE CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT IMMEDIATELY. QUANTITIES OF PLANTS SHOWN BY LANDSCAPE SYMBOLS SHALL GOVERN OVER THE QUANTITIES SHOWN IN THE PLANT SCHEDULE. 1.8 ALL MATERIALS SHALL BE SUBJECT TO APPROVAL BY THE LANDSCAPE ARCHITECT. THE OWNER SHALL RECEIVE TAGS FROM EACH PLANT SPECIES AND A LIST OF PLANT SUPPLIERS. WHERE ANY REQUIREMENTS ARE OMITTED FROM THE PLANT LIST, THE PLANTS FURNISHED SHALL MEET THE NORMAL REQUIREMENTS FOR THE VARIETY OR CULTIVAR PER THE AMERICAN STANDARD FOR NURSERY STOCK, LATEST EDITION, PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN). PLANTS SHALL BE PRUNED PRIOR TO DELIVERY ONLY UPON THE APPROVAL OF THE LANDSCAPE ARCHITECT. 1.9 NO SUBSTITUTIONS OF PRODUCTS, PLANT TYPES OR SIZES SHALL BE MADE WITHOUT WRITTEN APPROVAL OF THE OWNER, LANDSCAPE ARCHITECT, AND MUNICIPAL REVIEW AGENCY. REQUESTS FOR SUBSTITUTION SHALL BE IN WRITING, AND SHALL STATE THE REASONS FOR THE SUBSTITUTION REQUEST, THE SUGGESTED ALTERNATIVE, AND THE CHANGES IN COST. REQUESTS FOR SUBSTITUTION IN PLANT MATERIAL SHALL STATE THE NAMES OF NURSERIES WHO HAVE BEEN UNABLE TO SUPPLY THE ORIGINALLY SPECIFIED MATERIAL. 1.10PLANTING SHALL ONLY OCCUR DURING SPECIFIED PLANTING SEASONS. SPRING SEASON SHALL BE FROM MARCH 1 TO JUNE 15. FALL PLANTING SEASON SHALL BE FRO SEPTEMBER 15 TO NOVEMBER 15. 1.11 THE CONTRACTOR SHALL GUARANTEE ALL LANDSCAPE IMPROVEMENTS, INCLUDING SEEDING, FOR ONE FULL YEAR AS REQUIRED BY THE SPECIFICATIONS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL PLANT MAINTENANCE DURING THE GUARANTEE PERIOD. 1.12INSTALLED UNIT PRICES FOR ALL PLANT MATERIAL SHALL BE SUPPLIED TO THE OWNER AND LANDSCAPE ARCHITECT AT THE TIME OF BIDDING. 1.13 THE LANDSCAPE CONTRACTOR IS TO PERFORM A THOROUGH CLEANUP AND QUALITY CONTROL INSPECTION WITHIN 12 HOURS PRIOR TO THE OPENING OF THE POOL. 1.14 THE LANDSCAPE CONTRACTOR IS SUBJECT TO RANDOM INSPECTIONS BY THE OWNER AND/OR THE OWNER'S REPRESENTATIVE AT ANY TIME DURING THE INSTALLATION PROCESS. TREE/SHRUB PLANT LIST:BOTANICAL NAME: SIZE: COUNT:SYMBOL: RED MAPLE ACER RUBRUM 2" CAL., 6' HT. 83 ALL STREET TREES SHALL BE AT LEAST TWO (2) INCHES IN CALIPER AND A MINIMUM OF SIX (6) FEET IN HEIGHT AT THE TIME OF PLANTING. STREET TREES SHALL BE PLANTED IN A LINEAR ARRANGEMENT PARALLEL TO THE STREET NO LESS THAN FIVE (5) FEET AND NO MORE THAN 10 FEET OUTSIDE THE RIGHT-OF-WAY. STREET TREES SHALLBE PLANTED AT LEAST EIGHT (8) FEET FROM UTILITY POLES AND 10 FEET FROM ELECTRICALTRANSFORMERS. KEEP MULCH AWAY FROM TRUNK MULCH, MIN. DEPTH OF 4" 3" MIN. - 6" MAX.TOP OF BALL FINISHED GRADE BOTTOM OF BALL BOTTOM OF PIT 6" MIN ROOTBALL, AS NOTED UNDISTURBED NATIVE SOIL PEDESTAL 2.5 X BALL DIA. (MIN.) 6" MIN. HIGH NATIVE SOIL SAUCER NATIVE SOIL BACKFILL 12" MIN FINISHED GRADE SET SHRUB PLUMB SHRUB PLANTING SCALE: N.T.S. PLANT BED: NATIVE SOIL BACKFILL, DEPTH AS NOTED FINISHED GRADE AND TOP OF PLANT BED EQUAL "X" MIN 2/3 "X" MIN MULCH, DEPTH AS NOTED INCREASE DEPTH OF MULCH AS DETAILED, AT EDGE OF ALL PLANTING BEDS. FINISHED GRADE OF LAWN OR WALK 'X' AS NOTED PLANT BED EDGING DETAIL SCALE: N.T.S. KEEP MULCH AWAY FROM TRUNK MULCH, MIN. DEPTH OF 4" 3" MIN. - 6" MAX.TOP OF BALL FINISHED GRADE BOTTOM OF BALL BOTTOM OF PIT 6" MIN ROOTBALL, AS NOTED UNDISTURBED NATIVE SOIL PEDESTAL 2.5 X BALL DIA. (MIN.) 6" MIN. HIGH NATIVE SOIL SAUCER NATIVE SOIL BACKFILL WOOD OR METAL STAKES 12" MIN FINISHED GRADE RUBBER HOSES GUY WIRES, WITH TURNBUCKLES SET TREE PLUMB SHADE AND UNDERSTORY TREE PLANTING SCALE: N.T.S. 4 NORTHVICINITY MAP NOT TO SCALE 8 7 24 MARKS ROADSR1111CAMERONHILL ROADSR1108GILCH RIS T ROAD SR114 3 W R O A D SR11 1 0 RIPLEY R D SITE Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHCEDAR POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION0' SCALE IN FEET 40 80 160