HomeMy WebLinkAboutMason Landing_approved Prelim.CDsCivil Engineering:SCALE: N.T.S.VICINITY MAPMASON LANDING SUBDIVISIONNThe Curry Engineering Group, PLLCNC License # P-0799PO Box 2018205 S. Fuquay AveFuquay-Varina, NC 27526919.552.0849 (o)919.880.9857 (m)Contact: Don Curry, PEdon@curryeng.comDeveloper / Land Owner:HARNETT COUNTY, NORTH CAROLINAMAJOR SUBDIVISION - CONSTRUCTION DRAWINGSHARNETT COUNTYSITEGOVERNING AGENCIES:UTILITY AGENCIES:PLANNING/ZONING/LANDSCAPEHARNETT COUNTYPLANNING DEPT.108 E. FRONT STREETLILLINGTON, NC 27546910.893.7525 OPT. 4CONTACT: MR. LANDON CHANDLEREROSION CONTROLSTORMWATERWATER & SEWERHARNETT REGIONAL WATER700 McKINNEY PARKWAYLILLINTON, NC 27546910.893.7575CONTACT: MR. SHANE CUMMINGSNCDENR-DWQ SEWERNCDENR DIVISION OF WATER RESOURCESFAYETTEVILLE REGIONAL OFFICE225 GREEN STREETSUITE 714FAYETTEVILLE, NC 28301910.433.3300NCDENR-PUBLIC WATER SUPPLYNCDENR DIVISION OF WATER RESOURCESRALEIGH REGIONAL OFFICE512 N. SALISBURY STREETRALEIGH, NC 27604919.707.9100ENGINEERINGHARNETT REGIONAL WATER700 McKINNEY PARKWAYLILLINTON, NC 27546910.893.7575CONTACT: MR. SHANE CUMMINGSCOVER SHEETC0.0N.T.SDRAWING INDEXSheet NumberSheet Ti
tleC0.0COVER SHEETC0.1CIVIL NOTESC0.2HRW NOTES IC0.3HRW NOTES IIC1.0EXISTING CONDITIONS & DEMOLITION PLANC2.0OVERALL SITE LAYOUTC2.1PARTIAL SITE LAYOUT IC2.2PARTIAL SITE LAYOUT IIC3.0OVERALL UTILITY PLANC3.1PARTIAL UTILITY PLAN IC3.2PARTIAL UTILITY PLAN IIC4.0OVERALL GRADING AND DRAINAGE PLANC4.1PARTIAL GRADING AND DRAINAGE PLAN IC4.2PARTIAL GRADING AND DRAINAGE PLAN IIC5.1.1SAWYER DRIVE PLAN AND PROFILE IC5.1.2SAWYER DRIVE PLAN AND PROFILE IIC5.2SS OUTFALL PLAN AND PROFILEC5.3WATER MAIN PROFILEC6.0SITE DETAILSC6.1WATER DETAILS IC6.2WATER DETAILS IIC6.3SANITARY SEWER DETAILSL1.0LANDSCAPE PLANEC1.0EROSION CONTROL PLAN - INITIAL PHASEEC2.0EROSION CONTROL PLAN - CONSTRUCTION PHASEEC3.0EROSION CONTROL DETAILS IEC4.0EROSION CONTROL DETAILS IIEC5.0EROSION CONTROL DETAILS IIIEC6.0EROSION CONTROL DETAILS IVPROSPECT CHURCH RD (SR 2009)NCDEQ DIVISION OF ENERGY, MINERAL & LANDRESOURCESRALEIGH REGIONAL OFFICE512 N. SALISBURY STREETRALEIGH, NC 27604919.807.6369CONTACT: MR. JIM FARKISNCDEQ DIVISION OF ENERGY, MINERAL & LANDRESOURCESFAYETTEVILLE REGIONAL OFFICE225 GREEN STREETSUITE 714FAYETTEVILLE, NC 28301910.433.3300CONTACT: JODI PACEENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526(919) 552-0849(919) 552-2043CURRY ENGINEERSNORTH CAROL
INA EST.10NC LIC. NO. P-0799TFZ:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C0.0 COVER SHEET.DWGPLOTTED: 8/2/2022 2:53 PM PROFESSIONAL'S SEALDATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONS 24 x 36STATUSCONSULTANTCLIENTCONSTRUCTION DRAWINGSMASON LANDING SUBDIVISIONAUGUST 20, 20212021-026RELEASEDFOR CONSTRUCTIONLong Land Development, LLC9404 Northfield Ct.Raleigh, NC 27603919-810-6151 (m)Contact: Hal Longhallong@att.net01 / 14 / 20221NCDEQ COMMENT REVISION01 / 26 / 20222HRW COMMENT REVISION02 / 01 / 20223NCDOT COMMENT REVISION02 / 25 / 20224HRW COMMENT REVISION03 / 09 / 20225HRW COMMENT REVISION03 / 25 / 20226NCDEQ PWSS COMMENT REVISION03 / 30 / 20227RELEASED FOR CONSTRUCTION07 / 08 / 20228HARNETT PLANNING COMMENT REVISIONNC 55NCDOTNC DEPT. OF TRANSPORTATIONDIV. 6, DISTRICT 2600 SOUTHERN AVENUEFAYETTEVILLE, NC 28302910.364.0601CONTACT: MR. RICHIE HINESOWNER'S CONSENT FORMLong Land Development, LLC9404 Northfield Ct.Raleigh, NC 27603919-810-6151 (m)Contact: Hal Longhallong@att.netFIRST SUBMITTED TO HARNETT COUNTY: SEPTEMBER 17, 2021Surveyor:Mauldin-Watkins Surveying, PAP.O. BOX 444/1301 W. Broad StreetFuquay-Varina, NC 27526919.552.9326Contact: Wayne Mauldin, PLSSITE INFORMATIONZONING:COUNTY:LOCATION:PARENT PIN:DB/PG:ACREAGE:HARNETTLAND CLASS:LOW-DENSITY RESIDENTIALRIGHT OF WAY & OTHER AREAS:RIGHT OF WAY DEDICATION:33,367 SF (0.77 AC)20.06 AC3972 / 00511508-08-2742 & 1508-08-1016LOT ACREAGE:TOTAL NUMBER PROPOSED LOTS:PROPOSED DENSITY:MINIMUM ALLOWED LOT SIZE:MINIMUM PROPOSED LOT SIZE:MAXIMUM PROPOSED LOT SIZE:AVERAGE PROPOSED LOT SIZE:29,320 SF45,732 SF25,400 SF25,000 SF1.14 DU/AC22SIDE YARD:FRONT YARD:35'10'REAR YARD:25'MINIMUM BUILDING SETBACKS:CORNER YARD:20'MINIMUM ALLOWABLE LOT WIDTH:100'100'NUMBER OF PHASES:1IMPERVIOUS AREAS:ROADWAYS / PARKING:0.55 ACLOTS (5,000 SF/LOT):TOTAL ON-SITE IMPERVIOUS AREA:TOTAL ON-SITE IMPERVIOUS PERCENT:UTILITY DEMANDSWATER USAGE:2.53 AC3.08 AC15.4%7,920 GPD3 BED X 120 GPD/BED X 22 UNITSRA-30PROSPECT CHURCH RD.DUNN, NC 28334MINIMUM PROPOSED LOT WIDTH @FRONT BUILDING SETBACK:AREA AFTER DEDICATION:19.29 ACTOWNSHIP:GROVEAPPROVAL OF THIS PLAT/PLAN DOES NOT GUARANTEE WATER CAPACITY ORWASTEWATER CAPACITY. CURRENT/FUTURE CAPACITY MAY NOT BE AVAILABLE.THIS DEVELOPMENT MAY REQUIRE ADDITIONAL IMPROVEMENTS TO THE EXISTINGWATER AND WASTEWATER SYSTEM TO MEET FUTURE WATER AND WASTEWATERDEMANDS PRIOR TO A PRELIMINARY PLAT, CONSTRUCTION PLAN AND/OR FINALPLAT APPROVAL.HARNETT COUNTY REQUIRED NOTE:
C0.1
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C0.1 CIVIL NOTES.DWGPLOTTED: 8/1/2022 10:18 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
CIVIL NOTES
1.TOPOGRAPHICAL DATA PERFORMED BY MAULDIN-WATKINS SURVEYING, PA. SITE BENCHMARK IS AVAILABLE FROM
SURVEYOR. CONTOURS SHOWN HEREON ARE FROM AN ACTUAL FIELD SURVEY. BOUNDARY INFORMATION
SUPPLIED BY OWNER AND SHOWN FOR REFERENCE ONLY. CONSULT PLS FOR ACTUAL BOUNDARY DATA.
2.ALL WORK, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE HARNETT COUNTY STANDARDS
AND SPECIFICATIONS, LATEST EDITION.
3.ALL WORK, CONSTRUCTION AND MATERIALS WITHIN NCDOT RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH THE
2018 NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES.
4.ALL RIGHT OF WAYS SHALL BE PUBLIC & NCDOT MAINTAINED.
5.THIS SITE IS NOT LOCATED IN A FLOOD HAZARD ZONE PER FEMA MAPS 3720150800J DATED OCT 3, 2006.
6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ZONE TRAFFIC CONTROL IN OR ADJACENT TO NCDOT
RIGHT-OF-WAY. TRAFFIC CONTROL SHALL BE MAINTAINED AT ALL TIMES WITH PROPER SIGNAGE, SIGNALS,
LIGHTING, FLAGMEN. ALL SIGNS, PAVEMENT MARKINGS AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM
TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION.
7.COPIES OF ALL PERMITS AND APPROVED PLANS MUST BE KEPT ON SITE IN A PERMIT BOX THAT IS
CONSPICUOUSLY LOCATED AND EASILY ACCESSIBLE DURING CONSTRUCTION. THIS INCLUDES APPROVED
CONSTRUCTION PLANS, APPROVED EROSION CONTROL PLANS, ENCROACHMENT AGREEMENTS, DRIVEWAY
PERMITS, WATER/SEWER PERMITS, ETC.
8.LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE AND MUST BE FIELD VERIFIED. CONTACT THE NC ONE
CALL CENTER AT LEAST 48 HOURS PRIOR TO DIGGING @ 1.800.632.4949. UNDERGROUND LINES SHOWN HEREON
ARE APPROXIMATE OR AS REPORTED BY VARIOUS RESPONSIBLE PARTIES. THE SURVEYOR DOES NOT
GUARANTEE THAT ANY UNDERGROUND STRUCTURES SUCH AS UTILITIES, TANKS AND PIPES ARE LOCATED
HEREON.
9.THE CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OR FIRMS HAVING FACILITIES
ON OR ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING OR
CONNECTING TO SAID FACILITIES.
10.THE CONTRACTOR IS RESPONSIBLE FOR REPAIR OF ANY COUNTY OR NCDOT DAMAGED PROPERTY. THE
CONTRACTOR SHALL REPAIR THE DAMAGED PROPERTY TO THE LATEST STANDARDS AND SPECIFICATIONS OF THE
AGENCY HOLDING JURISDICTION AT NO COST TO THE OWNER.
11.ANY DAMAGE DONE TO PRIVATE PROPERTY OWNERS SIGNS, MAILBOX, DRIVEWAY CULVERTS, OR OTHER
PROPERTY SHALL BE RESTORED TO ORIGINAL CONDITION.
12.CONTRACTOR IS RESPONSIBLE FOR FENCING AND SECURITY OF HIS LAYDOWN AND STORAGE AREA.
13.CONTRACTOR SHALL KEEP ALL ROADS FREE OF DIRT AND DEBRIS AT ALL TIMES.
14.CONTRACTOR SHALL PROTECT EXISTING PAVEMENTS AND UTILITIES FROM HEAVY EARTH MOVING EQUIPMENT.
PROVIDE TRAFFIC CONTROL AND ADEQUATE PROTECTION METHODS AT ALL EQUIPMENT CROSSINGS.
15.ALL EXCAVATION IS UNCLASSIFIED AND SHALL INCLUDE ALL MATERIALS ENCOUNTERED.
16.ALL STRUCTURAL FILL MATERIAL SHALL BE FREE OF ALL STICKS, ROCKS, AND CLUMPS OF MUD. ALL ROCKS
GREATER THAN 3" DURING EXCAVATION SHALL BE REMOVED.
17.UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE
DISPOSED OF OFF-SITE BY THE CONTRACTOR IN AN APPROVED, LEGAL DISPOSAL SITE.
18.CONCRETE SIDEWALKS THAT ARE TO BE REMOVED SHALL BE CUT BACK TO NEAREST EXPANSION OR CONTROL
JOINT AND REPLACED WITH 4-INCH CONCRETE SIDEWALK FINISHED TO MATCH EXISTING SIDEWALKS.
19.CONTRACTOR TO COORDINATE WITH HARNETT REGIONAL WATER FOR TEMPORARY WATER NEEDED DURING
CONSTRUCTION. IF PERMITTED TO CONNECT TO EXISTING FIRE HYDRANT, A REDUCED PRESSURE ZONE (RPZ)
BACKFLOW PREVENTER WILL BE REQUIRED.
20.THE TRANSITION OF PROPOSED ROADWAY TO EXISTING ROADWAY SHALL BE DONE WITH A MINIMUM 8-FT
TRANSITION WHERE THE EXISTING PAVEMENT IS MILLED TO A MINIMUM DEPTH OF 1-1/2" AND OVERLAID.
21.ALL PAVEMENT SAW CUTS SHALL BE NEAT, STRAIGHT AND FULL DEPTH.
22.ALL RIP-RAP IS TO BE INSTALLED WITH NON-WOVEN FILTER FABRIC BENEATH (MIRAFI 140 N OR APPROVED EQUAL).
23.ALL EXCESS TOPSOIL AND UNCLASSIFIED EXCAVATION IS TO BE HAULED OFF-SITE, UNLESS OTHERWISE DIRECTED
BY THE OWNER TO AN APPROVED NCDENR LOCATION.
24.ALL SITE CONSTRUCTION MUST BE INSPECTED BY THE GEOTECHNICAL ENGINEER AT THE FOLLOWING STAGES:
A.COMPLETION OF GRADING SUBGRADE PRIOR TO PLACING STONE BASE.
B. COMPLETION OF STONE PLACEMENT PRIOR TO PAVING.
C.FINAL INSPECTION WHEN ALL WORK IS COMPLETE.
25.PRIOR TO PLACING CABC STONE BASE, THE CONTRACTOR SHOULD NOTIFY THE GEOTECHNICAL ENGINEER TO
INSPECT THE PROOF ROLL OF THE SUBGRADE. ANY STONE PLACED WITHOUT PRIOR APPROVAL WILL BE THE
SOLE RESPONSIBILITY OF THE CONTRACTOR AND SUBJECT TO RE-CONSTRUCTION IF SUBGRADE DOES NOT MEET
NCDOT STANDARDS & SPECIFICATION
26.ALL UTILITY SERVICES, (POWER, TELEPHONE, CABLE, ETC.) ARE PROPOSED TO BE UNDERGROUND. DO NOT SEED
OR MULCH DISTURBED AREAS UNTIL ALL UNDERGROUND UTILITIES HAVE BEEN INSTALLED. THE CONTRACTOR
SHALL COORDINATE WITH THE PRIVATE UTILITY SERVICE COMPANIES FOR ANY REQUIRED CONDUITS OR POINT OF
CONTACT CONDITIONS.
27.ALL PUBLIC UTILITIES THAT REQUIRE AN ENGINEERING CERTIFICATION MUST BE INSPECTED BY A PROFESSIONAL
ENGINEER ON A PERIODIC BASIS. THE CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER WHEN INSTALLING
UTILITIES FOR PERIODIC INSPECTIONS. THE CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER AT THE TIME
OF PRESSURE TESTING AND WATER LINE DISINFECTION. THE CONTRACTOR SHALL SUPPLY THE PROJECT
ENGINEER PRESSURE TEST RESULTS.
28.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD
CONDITIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATION
OF ALL EXISTING UTILITIES BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF
TRENCHING. IF THE CLEARANCES ARE LESS THAN SPECIFIED ON THE PLANS OR 12 INCHES, WHICH EVER IS LESS,
CONTACT THE PROJECT ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION.
29.THE CONTRACTOR SHALL INCLUDE IN HIS CONTRACT PRICE THE REMOVAL AND DISPOSAL OF ANY EXCESS
TOPSOIL HE DETERMINES IS NOT REQUIRED TO PERFORM THE FINAL GRADING AND LANDSCAPING OPERATION.
30.THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE DAILY RECORD KEEPING OF THE AS-BUILT
CONDITION OF ALL OF THE UNDERGROUND UTILITIES, CONSTRUCTION STAKEOUT ASSOCIATED WITH THE
PROJECT. PREPARATION OF THE NECESSARY/REQUIRED AS-BUILT PLANS TO BE SUBMITTED TO HARNETT
COUNTY AND/OR ALL OTHER INFORMATION REQUIRED IN CONNECTION WITH RELEASE OF BONDS.
31.THE CONTRACTOR SHALL INCLUDE IN THE PRICE, ANY AND ALL COSTS ASSOCIATED WITH PROVIDING A
PROFESSIONAL ENGINEER ON SITE IF REQUIRED, DURING THE CONSTRUCTION OF THE STORMWATER
MANAGEMENT FACILITIES, UNDERGROUND UTILITIES, ETC. AS REQUIRED FOR AS-BUILT CERTIFICATION.
32.THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY
SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA,
FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THE
DRAWINGS. NCDOT, HARNETT COUNTY & CURRY ENGINEERING ACCEPT NO RESPONSIBILITY FOR THE DESIGN TO
INSTALL SAID ITEMS.
33.TESTING BY CONTRACTOR: CONTRACTOR SHALL EMPLOY AT HIS EXPENSE AN OUTSIDE INDEPENDENT SOIL
TESTING SERVICE (APPROVED BY THE OWNER) TO PERFORM SOIL TESTING AND INSPECTION SERVICE FOR
QUALITY CONTROL TESTING DURING EARTHWORK OPERATIONS. COPIES OF RESULTS OF TESTS SHALL BE
SUBMITTED BY THE TESTING SERVICE DIRECTLY TO THE CONTRACTOR, THE OWNER, AND THE APPLICABLE
APPROVING AGENCY. --THE TESTING SERVICE WILL CLASSIFY PROPOSED ON-SITE AND BORROW SOILS TO VERIFY
THAT SOILS COMPLY WITH SPECIFIED REQUIREMENTS AND TO PERFORM REQUIRED FIELD AND LABORATORY
TESTING. (MINIMUM REQUIRED SOIL BEARING CAPACITY IS NOTED ON THE STRUCTURAL DRAWINGS). --IN PAVED
AND BUILDING SLAB AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD DENSITY TEST FOR EACH
2000 SQUARE FEET OF FILL IN EACH COMPACTED FILL LAYER. IF A TEST SHOULD FAIL TO MEET REQUIRED
DENSITY, THE CONTRACTOR SHALL RE-COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM
ADDITIONAL TESTS AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE
REQUIRED COMPACTION. --IN FOUNDATION WALL AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD
DENSITY TEST FOR EACH 100 FEET OR LESS OF WALL LENGTH OF FILL IN EACH COMPACTED FILL LAYER, WITH NO
LESS THAN TWO TESTS ALONG A WALL FACE. IF A TEST SHOULD FAIL TO MEET REQUIRED DENSITY, THE
CONTRACTOR SHALL RE-COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM ADDITIONAL TESTS
AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE REQUIRED COMPACTION.
34.COMPACTION: COMPACT EACH LAYER OF BACKFILL AND FILL SOIL MATERIALS AND THE TOP 12" OF SUBGRADE IN
CUT AREAS TO 100% OF MAXIMUM DENSITY IN ACCORDANCE WITH AASHTO T99 FOR STRUCTURES, SLABS, AND
PAVEMENTS AND 95% OF MAXIMUM DENSITY FOR EMBANKMENTS OR UNPAVED AREAS. MAX LIFT THICKNESS FOR
FILL AREAS IS 8 INCHES.
35.DISTURBED AREA IS IN EXCESS OF 1 ACRE AND FORMAL SEDIMENTATION & EROSION CONTROL PLAN APPROVAL IS
REQUIRED AS A CONDITION OF CONSTRUCTION PLAN APPROVAL. A COPY OF THE APPROVED EROSION CONTROL
PLAN MUST BE KEPT ON SITE AT ALL TIMES. THE APPROVED SEDIMENTATION & EROSION CONTROL PLAN SHOULD
BE REGARDED AS MINIMUM REQUIREMENTS; ADDITIONAL MEASURES SHALL BE PUT IN PLACE AS NEEDED TO
ENSURE THAT NO SEDIMENT IS RELEASED FROM THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR PICKING UP
AND PAYING FOR GRADING PERMIT ISSUED BY NCDENR DIVISION OF ENERGY, MINERALS AND LAND QUALITY.
36.DESIGN/FIELD CONDITIONS QUITE EASILY MAY VARY FROM THAT REPRESENTED IN THE INITIAL SOILS REPORT
AND/OR TOPOGRAPHICAL REPORT. ISOLATED AREAS MAY SHOW UP WEAK AND ADVERSE SOILS OR
GROUNDWATER CONDITIONS MAY BE DISCOVERED THAT WERE NOT REVEALED DURING THE INITIAL SOILS
INVESTIGATION. THEREFORE, THE OWNER/CLIENT IS TO BE AWARE THAT CURRY ENGINEERING GROUP, PLLC WILL
NOT AND CANNOT BE HELD RESPONSIBLE FOR ANY FAILURES TO EITHER A STREET OR PARKING LOT PAVEMENT
DESIGN UNLESS WE CAN BE FULLY AND TOTALLY INVOLVED IN THE CONSTRUCTION PROCESS WHICH MAY
INCLUDE, BUT MAY NOT NECESSARILY BE LIMITED TO, TESTING SUBGRADE AND BASE DENSITY, ENGAGING THE
GEOTECHNICAL ENGINEER FOR THE EVALUATION OF THE SUBGRADE AND FOR THE OBSERVATION OF PROOF
ROLLING SUBGRADE AND BASE AT VARIOUS STEPS OF CONSTRUCTION, OPPORTUNITY FOR THE DESIGN
ENGINEER TO CALL IN A GEOTECHNICAL ENGINEER FOR CONSULTATION AND ADVICE, ETC. - STEPS WHICH TAKEN
ALTOGETHER WITH THE INITIAL DESIGN SHOWN ON THE PLANS, CONSTITUTE THE COMPLETE DESIGN OF THE
ROAD, STREET OF PARKING AREA (PRIVATE OR PUBLIC). THE DESIGN ENGINEER MUST BE GIVEN THE FULL
LATITUDE AND OPPORTUNITY TO COMPLETE THE DESIGN BY FULLY PARTICIPATING IN THE CONSTRUCTION
PROCESS. PLAN DESIGN IS A SMALL PORTION OF THE DESIGN AND CANNOT BE SEPARATED FROM THE
CONSTRUCTION PROCESS IF THE OWNER'S/CLIENT'S DESIRE IS TO HAVE THE DESIGN ENGINEER STAND BEHIND
THE COMPLETED DESIGNED PROJECT.
GENERAL CONSTRUCTION NOTES:
P PROPERTY LINE
L
L
CENTERLINE
DIAMETER OR ROUND
C
AND &
-- C --
-- A --
-- B --
-- D --
-- E --
-- F --
-- G --
-- H --
-- I --
-- L --
** ALL SYMBOLS & ABBREVIATIONS SHOWN ON THIS SHEET
MAY OR MAY NOT BE USED IN THIS DRAWING PACKAGE **
IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION
GENERAL ABBREVIATIONS:
ABC AGGREGATE BASE
ASPH ASPHALT
AVE AVENUE
BLVD BOULEVARD
BLDG BUILDING
BOC BACK OF CURB
BW BOTTOM OF WALL
CB CATCH BASIN
CI CURB INLET
CIP CAST IRON PIPE
CLS CLASS
CJ CONTROL JOINT
CO CLEANOUT
CONC CONCRETE
DI DROP INLET
DIA DIAMETER
DIP DUCTILE IRON PIPE
DOM DOMESTIC
DR DRIVE
(XX) EXISTING ELEVATION
E EAST, EASTING
EL ELEVATION
EJ EXPANSION JOINT
EOP EDGE OF PAVEMENT
EX EXISTING
EVAP EVAPORATIVE
FDC FIRE DEPARTMENT
CONNECTION
FES FLARED END SECTION
FFE FINISHED FLOOR ELEVATION
FG FINISHED GRADE
FHA FIRE HYDRANT ASSEMBLY
FL FLOW LINE
FT FOOT OR FEET
G GAS
GALV GALVANIZED
GB GRADE BREAK
GE GENERAL ELECTRIC
GR GRADE
HWR HARNETT REGIONAL WATER
HDPE HIGH DENSITY POLYETHYLENE
HORIZ HORIZONTAL
HOV HIGH OCCUPANCY VEHICLE
HP HIGH POINT
IAW IN ACCORDANCE WITH
I.H.INTERSTATE HIGHWAY
INV INVERT
LEN LENGTH
LEV LOW EMISSION VEHICLE
LF LINEAR FEET
LP LOW POINT
www.ncocc.org
BEFORE YOU DIG,
CALL
NORTH CAROLINA
ONE CALL CENTER
-- M --
-- N --
-- O --
-- P --
-- R --
-- S --
-- T --
-- U --
-- V --
-- W --
-- Y --
MAX MAXIMUM
MH MANHOLE
MIN MINIMUM
N NORTH, NORTHING
NCDENR NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT & NATURAL RESOURCES
NCDOT NORTH CAROLINA DEPARTMENT OF
TRANSPORTATION
NTS NOT TO SCALE
OH OVERHEAD
OCB OFF-SET CATCH BASIN
PCC PORTLAND CEMENT CONCRETE
PE POLYETHYLENE
PKWY PARKWAY
POC POINT OF CONNECTION
PVC POLYVINYL CHLORIDE
R RADIUS
RCP REINFORCED CONCRETE PIPE
R.O.W. RIGHT OF WAY
RPDA REDUCED PRESSURE
DETECTOR ASSEMBLY
RPZ REDUCED PRESSURE ZONE
S SOUTH
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SDE SIGHT DISTANCE EASEMENT
SSMH SANITARY SEWER MANHOLE
SS SANITARY SEWER
STA STATION
STD STANDARD
ST.STL STAINLESS STEEL
SWPPP STORMWATER POLLUTION
PREVENTION PLAN
TB TOP OF BARRIER
TC/TOC TOP OF CURB
TD TEMPORARY DIVERSION
TH TEST HEADER
TOP TOP OF PIPE
TP TOP OF PAD
TYP TYPICAL
TW TOP OF WALL
UG UNDERGROUND
VEG VEGETATED
VERT VERTICAL
W WEST
W/ WITH
W/O WITHOUT
YI YARD INLET
IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION
C0.2
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C0.2 HRW NOTES I.DWGPLOTTED: 8/1/2022 10:18 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
HRW NOTES I
C0.3
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C0.3 HRW NOTES II.DWGPLOTTED: 8/1/2022 10:18 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
HRW NOTES II
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE
OHE
OHE
OHE
OHE
OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E
N 12°45'00"E 1172.41'S 81°31'23"E 639.16'S 12°44'46"W 708.94'S 12°45'01"W 897.84'N 42°57'51"W 622.35'N 60°53'53"W 128.41'S 77°14'51"E 637.43'661.28'511.13'(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS EIS
MAG NAIL CP
CP
15" RCP24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPPPP
PP
PP
PP PP PP PP PP PP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPFOM
GW
FOM FOM217216215218219220221 220
221
222
219220221222220219
220221
220
217
749.89 LF @ 0.22%721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
LONG LAND DEVELOPMENT, LLC
D.B. 3972, PG. 0051
PIN: 1508-08-2742
ZONING: RA-30
AREA: 10.03 AC
LONG LAND DEVELOPMENT, LLC
D.B. 3972, PG. 0051
PIN: 1508-08-1016
ZONING: RA-30
AREA: 10.03 AC
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
MH
TOP-217.73
INV-207.19
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT
WOODALL JR & LANDA
KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 213.59
INV: 213.13
INV: 214.07
INV: 213.80
219
220
22
1
EXISTING IRON PIPE (CONTROL POINT)
CONCRETE MONUMENT SET
EXISTING CONCRETE MONUMENT(CONTROL POINT)
IRON STAKE SET (UNLESS OTHERWISE NOTED)
40 D NAIL
EIS
ECS
COMPUTED POINT ONLY
PROPERTY BOUNDARY
EASEMENT
500 YR FLOOD PLAIN
100 YR FLOOD PLAIN
WTLD WETLANDS BOUNDARY
OHE OVERHEAD POWER
FLOODWAY
FLD
FW
EXISTING IRON STAKE
EXISTING COTTON SPIKE
MINOR CONTOUR
MAJOR CONTOUR350
Wx EXISTING WATER
SS x EXISTING SANITARY SEWER
FM EXISTING FORCE MAIN
Gx EXISTING NATURAL GAS
C/O
POWER-POLE
CLEANOUT
FIBER OPTIC MARKER
WATER METER
MANHOLE
FIRE HYDRANT
WATER VALVE
UTILITY DEMOLITION
APPURTENANCE/POLE REMOVAL
C1.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C1.0 EXISTING CONDITIONS & DEMOLITION PLAN.DWGPLOTTED: 8/1/2022 10:18 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
EXISTING CONDITIONS & DEMOLITION PLANNSCALE IN FEET
60'120'30'60'
SCALE: 1 IN = 60 FT
SCALE IN FEET
HORIZONTAL
0
1" = 60'
PROFESSIONAL ENGINEER SEAL
NOT AFFIXED TO SHEET AS
ENGINEER DOES NOT CERTIFY
INFORMATION PROVIDED BY
OTHERS
LEGEND:
Surveyor:
Mauldin-Watkins Surveying, PA
P.O. BOX 444/1301 W. Broad Street
Fuquay-Varina, NC 27526
919.552.9326
Contact: Wayne Mauldin, PLS
DUKE POWER LINE
PROPERTY LINE TO BE
REMOVED UPON
RECOMBINATION
PROPERTY
BOUNDARY
EXISTING
SS MAIN
EXISTING
TREELINE
EXISTING GAS LINE EXISTING 12" DIP
WATER MAIN
EXISTING
HOUSE TO
REMAIN
EXISTING
DRIVES TO
REMAIN
EXISTING OVERHEAD
POWER AND ASSOCIATED
POLES TO BE REMOVED
AND RELOCATED. SEE
UTILITY PLANS
GENERAL NOTES:
1.THIS PLAN IS NOT INTENDED FOR PLATTING OR RECORDATION.
2.THE INTENT OF THIS PLAN IS TO ILLUSTRATE THE EXISTING FEATURES, STRUCTURES AND
TOPOGRAPHY OF THE PROPERTY. THE INFORMATION SHOWN ON THIS PLAN WAS
PROVIDED AND DEVELOPED BY OTHERS. CURRY ENGINEERING DOES NOT GUARANTEE
THE ACCURACY OF THE INFORMATION, THUS IT HAS NOT BEEN SEALED. SURVEY
INFORMATION SHOWN WITHIN THE PARENT PROPERTY BOUNDARY REPRESENTS FIELD
SURVEY INFORMATION CONDUCTED IN JULY 2021 BY MAULDIN-WATKINS SURVEYING.
3.NO TITLE OPINION ON THIS PROPERTY HAS BEEN FURNISHED.
4.AREAS COMPUTED BY THE COORDINATE METHOD.
5.THE PROPERTY SHOWN HEREON IS SUBJECT TO ALL RIGHTS-OF-WAY, EASEMENTS,
COVENANTS, AND RESTRICTIONS OF RECORD.
6.ALL DISTANCES SHOWN ON THE SURVEY ARE HORIZONTAL GROUND DISTANCES.
5.THIS SITE IS NOT LOCATED IN A FLOOD HAZARD ZONE PER FEMA MAPS 3720150800J DATED
OCT 3, 2006.
6.VERTICAL DATUM: NAVD88, HORIZONTAL DATUM: NAD83
7.CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS, DEPTHS, AND MATERIALS OF ALL
EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION ACTIVITY ON SITE.
UNDERGROUND UTILITIES ARE SHOWN BASED ON MARKINGS PROVIDED BY THE NC ONE
CALL CENTER AND ABOVE GROUND EVIDENCE. EXISTING CONDITIONS SHOULD BE
CONSIDERED APPROXIMATE IN NATURE. WHILE EVERY EFFORT HAS BEEN MADE TO
ENSURE THE ACCURACY OF THE INFORMATION GIVEN, ACTUAL FIELD CONDITIONS MAY
VARY AND SHOULD BE CONFIRMED PRIOR TO CONSTRUCTION.
8.NO TEMPORARY OR PERMANENT ENCROACHMENTS (INCLUDING BUT NOT LIMITED TO
CLEARING, GRADING, FENCING, AND THE INSTALLATION OF RETAINING WALLS OR OTHER
STRUCTURES) ARE PERMITTED WITHIN THE GREENWAY EASEMENT AREA WITHOUT PRIOR
APPROVAL BY THE CITY OF RALEIGH.
DEMOLITION LEGEND
DEMOLITION NOTES:
1.ANY ITEM THAT MAY BE ENCOUNTERED DURING BUILDING DEMOLITION THAT MAY BE
OF INTEREST OR VALUE TO THE OWNER SHALL REMAIN THE OWNER'S PROPERTY.
COORDINATE PROCEDURE FOR REMOVAL AND SALVAGE WITH OWNER.
2.CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING PRE-DEMOLITION
PHOTOGRAPHS AND/OR VIDEOTAPE SHOWING EXISTING CONDITIONS OF ADJOINING
CONSTRUCTION AND SITE IMPROVEMENTS PRIOR TO ANY DEMOLITION WORK.
3.CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH GOVERNING EPA
REGULATIONS AND HAULING AND DISPOSAL REGULATIONS OF LOCAL JURISDICTION,
INCLUDING OBTAINING ALL REQUIRED PERMITS.
4.CONTRACTOR SHALL IMMEDIATELY NOTIFY OWNER IN THE EVENT THAT
UN-ANTICIPATED HAZARDOUS MATERIALS ARE ENCOUNTERED. CONTRACTOR SHALL
COMPLY WITH ALL REQUIREMENTS AND REGULATIONS REGARDING THE HANDLING
AND DISPOSAL OF HAZARDOUS MATERIALS.
5.CONTRACTOR RESPONSIBLE FOR LOCATING, IDENTIFYING, DISCONNECTING, AND
SEALING OR CAPPING UTILITIES SERVING BUILDINGS AND STRUCTURES TO BE
DEMOLISHED.
6.UNLESS OTHERWISE NOTED ON DRAWINGS, DEMOLITION SHALL INCLUDE REMOVAL OF
EXISTING OBJECTS OR IMPROVEMENTS (WITH THE EXCEPTION OF TREES) THAT
WOULD INTERFERE WITH PROGRESS OR COMPLETION OF PROPOSED WORK.
7.CONTRACTOR SHALL BE RESPONSIBLE FOR EROSION CONTROL DURING DEMOLITION.
8.CONTRACTOR SHALL NOTIFY OWNER AT LEAST 48 HOURS PRIOR TO COMMENCEMENT
OF DEMOLITION ACTIVITIES.
9.CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTION TO ENSURE THAT UTILITY
SERVICES OF ADJOINING PROPERTIES ARE NOT DISTURBED DURING SITE DEMOLITION.
10.CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL OFFSITE IMPROVEMENTS
DURING DEMOLITION AND COORDINATING RELOCATION OF ANY UTILITY SERVICES
DISRUPTED BY DEMOLITION ACTIVITIES.
11.PAVEMENT REMOVAL INCLUDES THE REMOVAL OF ANY ASSOCIATED BASE COURSE
AND CURBING.
12.CONTRACTOR SHALL FIELD VERIFY ALL UTILITIES BEFORE COMMENCING DEMOLITION
ACTIVITIES.
13.CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER SHOULD ANY DISCREPANCIES
OR CONFLICTS ARISE.
14.REMOVE ALL EXISTING STRUCTURES INCLUDING FOUNDATIONS.
15.REMOVE ALL ITEMS SHOWN ON EXISTING CONDITIONS PLAN AS NEEDED FOR
INSTALLATION OF NEW WORK.
16.NO EQUIPMENT IS ALLOWED ON THE SITE UNTIL ALL TREE PROTECTION AND SILT
FENCING HAS BEEN INSTALLED AND APPROVED.
17.CONTRACTOR SHALL CONTACT PUBLIC UTILITIES ADMINISTRATION DIVISION PRIOR TO
ANY DEMOLITION TO INSURE EXISTING WATER AND SANITARY SEWER DISCONNECTS
ARE HANDLED ACCORDING TO TOWN GUIDELINES. SEE COVER FOR CONTACT INFO.
18.SEE SITE/UTILITY PLAN & GRADING/DRAINAGE PLAN FOR PROPOSED MODIFICATIONS
TO UTILITIES & DRAINAGE STRUCTURES.
19.CONTRACTOR TO COORDINATE WITH UTILITY PROVIDER ON REMOVAL/RELOCATION OF
ALL UTILITY POLES, LINES, AND GUY WIRES. SEE COVER SHEET FOR CONTACT INFO.
REMOVE EXISTING
DRIVEWAY PIPE
CBU
ROADWAY CENTER LINE
RIGHT OF WAY LINE
LOT LINE
SETBACK LINE
SIGN
STREET LIGHT
CLUSTER MAILBOX UNIT
UTILITY/STORM EASEMENT
FENCE
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHE
OHE
OHE
OHE
OHE
OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
EIS
MAG NAIL CP
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP PP PP PP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPFOM
GW
FOM FOM
749.89 LF @ 0.22%721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
MH
TOP-217.73
INV-207.19
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT
WOODALL JR & LANDA
KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
1
11
10
12
13
9
20 1516171819
2 3 4 5 867
LOT
26,983 SQFT.
0.62 AC.
LOT
26,715 SQFT.
0.61 AC.
LOT
26,715 SQFT.
0.61 AC.
LOT
26,714 SQFT.
0.61 AC.
LOT
26,714 SQFT.
0.61 AC.
LOT
26,714 SQFT.
0.61 AC.
LOT
26,713 SQFT.
0.61 AC.
LOT
26,686 SQFT.
0.61 AC.
LOT
34,772 SQFT.
0.80 AC.
LOT
48,897 SQFT.
1.12 AC.
LOT
46,521 SQFT.
1.07 AC.
LOT
46,119 SQFT.
1.06 AC.
LOT
25,600 SQFT.
0.59 AC.
LOT
26,041 SQFT.
0.60 AC.
LOT
26,043 SQFT.
0.60 AC.
LOT
26,041 SQFT.
0.60 AC.
LOT
26,041 SQFT.
0.60 AC.
LOT
26,040 SQFT.
0.60 AC.
LOT
26,199 SQFT.
0.60 AC.43.25'54.40'54.88'56.30'19.20'58.76'254.43'16.33'
110.24'
41.7
4
'
105.00'
105.00'254.43'105.00'
105.00'254.42'105.00'
105.00'254.42'105.00'
105.00'254.42'254.41'105.00'
105.00'105.00'254.41'105.00'
105.00'248.97'16.81'89.43'
234.13'290.63'65.17'4.22'4
1
.
1
1
'
88.86'248.91'253.80'
37
3
.
6
2
'50.49'305.01'338.23'225.11'56.92'248.00'63.45'21.0
2
'
27.
5
0
'
105.00'248.00'105.00'
105.00'248.01'105.00'
105.00'248.01'105.00'
49.35'55.67'248.01'105.00'
105.00'248.00'105.00'
105.00'248.00'105.00'
105.00'255.67'63.29'42.33'
105.00'
73.20'
105.00'263.23'2.70'33.14'21.
7
6
'148.49'175.31'241.02'0.00'56.48'54.21'53.77'53.89'18.91'69.63'14
LOT
26,040 SQFT.
0.60 AC.
CBU
20+18
10+
0
0
11+
0
0
12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00
L1
C1 L2
21
LOT
28,687 SQFT.
0.66 AC.
LOT
41,616 SQFT.
0.96 AC.53.31'33.64'8.64'30.
0
0
'
22
SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
C2.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C2.0 OVERALL SITE LAYOUT.DWGPLOTTED: 8/1/2022 10:19 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
OVERALL SITE LAYOUT
SCALE IN FEET
60'120'30'60'
SCALE: 1 IN = 60 FT
SCALE IN FEET
HORIZONTAL
0
GENERAL NOTES:
THE FOLLOWING NOTES ARE APPLICABLE TO SITE SHEETS C2.0 THRU C2.2
1.ALL CONSTRUCTION SHALL BE PER HARNETT COUNTY STANDARDS AND SPECIFICATIONS.
2.ALL DIMENSIONS ARE IN FEET AND TO EOP UNLESS OTHERWISE NOTED.
3.ALL SITE ELEMENTS ARE PERPENDICULAR TO EACH OTHER UNLESS OTHERWISE NOTED.
4.CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, RIGHT-OF-WAYS AND
UTILITIES, PUBLIC OR PRIVATE, BEFORE WORKING IN THESE AREAS.
5.PROTECT ALL PROPERTY MONUMENTS AND PINS. MONUMENTS AND PINS THAT WILL BE
DISTURBED DURING CONSTRUCTION SHALL BE REFERENCED AND REPLACED BY A LICENSED
LAND SURVEYOR AT THE COST OF THE CONTRACTOR.
6.CONTRACTOR SHALL MAINTAIN THE SITE IN SUCH A MANNER THAT WORKMEN AND THE
PUBLIC WILL BE PROTECTED FROM INJURY AND ADJOINING PROPERTY PROTECTED FROM
DAMAGE
7.CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE UPON COMPLETION
OF THE PROJECT AND AT LEAST ONCE A WEEK DURING CONSTRUCTION.
8.CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL DUE
TO CONSTRUCTION OPERATIONS. ALL STREET SURFACES, UTILITY POLES, CULVERTS,
DITCHES, CURB AND GUTTER OR OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED
IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED BY
THE CONTRACTOR IN ACCORDANCE WITH THE APPROPRIATE SPECIFICATIONS.
9.IF DEPARTURES FROM THE DRAWINGS OR SPECIFICATIONS ARE DEEMED NECESSARY BY
THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREOF SHALL BE
SUBMITTED IN WRITING TO THE FACILITY DESIGNER FOR REVIEW. NO DEPARTURES FROM
THE CONTRACT DOCUMENTS WILL BE ALLOWED WITHOUT APPROVAL BY THE FACILITY
DESIGNER.
10.ANY AND ALL QUANTITIES SHOWN OR IMPLIED ON THE PLANS ARE FOR ESTIMATION
PURPOSES ONLY.
11.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES.
WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED
FROM THE AFFECTED PROPERTY OWNERS.
12.ENTRY SIGNS SHALL BE LOCATED IN A DEDICATED EASEMENT. SIGN MUST REMAIN OUT OF
SIGHT TRIANGLES AS SHOWN ON PLANS. ENTRY SIGNS WILL REQUIRE A SEPARATE SIGN
PERMIT.
13.ALL ASPHALT EDGES SHALL BE SAW CUT TO PROVIDE A GOOD LONGITUDINAL JOINT. MILL 1.5
FEET @ 1.5 INCHES DEEP MINIMUM TO PROVIDE A LONGITUDINAL LAP JOIN FOR FINAL
SURFACE LAYER. NO MILLING SHALL BE LEFT FOR A PERIOD OF TIME GREATER THAN 48
HOURS BEFORE A STREET IS TO BE PAVED OR RESURFACED.
14.COMMON OPEN SPACE SHALL BE OWNED & MAINTAINED BY HOMEOWNERS' ASSOCIATION.
15.ANY SPECIALITY STREET SIGNS INCLUDING POSTS SHALL BE SUBMITTED TO THE HARNETT
COUNTY FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION.
16.ALL PUBLIC AND PRIVATE EASEMENTS SHALL BE RECORDED AS PART OF THE FINAL PLAT OF
THE SUBDIVISION. EASEMENTS BASED OF CENTER OF UTILITY OR PIPE SHALL BE PER
AS-BUILT LOCATIONS.
17.AREAS OF PARENT PARCEL THAT ARE NOT SUBDIVIDED TO CREATE SINGLE FAMILY
RESIDENTIAL LOTS ARE TO REMAIN AS ONE PARCEL TO BE OWNED AND MAINTAINED BY THE
HOME OWNERS' ASSOCIATION OF THE NEIGHBORHOOD.
18.CONTRACTOR SHALL CONTACT HARNETT COUNTY UTILITIES PRIOR TO MAKING CONNECTION
TO ANY COUNTY OWNED INFRASTRUCTURE.
19.THIS DEVELOPMENT IS WITHIN 1 MILE OF A VOLUNTARY AGRICULTURAL DISTRICT.
20.BUILDINGS WITHIN 10% OF THE REQUIRED SETBACK ARE REQUIRED TO PROVIDE
FOUNDATION SURVEYS.
21.ALL SIGNAGE, MAILBOX KIOSK, DRAINAGE EASEMENTS, AND LANDSCAPING SHALL BE
MAINTAINED BY THE HOA.
22.HIGHWAY 55 IS ON THE HARNETT COUNTY COMPREHENSIVE TRANSPORTATION PLAN.
LEGEND:NCORNER LOT STANDARD LOT
10'25'25'
10'10'
20'
35'35'
FRONTFRONT
REARREARCORNERSIDESIDE SIDESCALE:
1
C2.0
TYPICAL BUILDING SETBACKS
NTS
RESIDENTIAL RA-30
1" = 60'
CBU MAILBOX
KIOSK
EXISTING EOP
LOT 22 TO BE
CREATED VIA
RECOMBINATION
PLAT
25' ROW DEDICATION
30' STREETSCAPE BUFFER
30' STREET YARD
20' PUBLIC
UTILITY
EASEMENT
30' STREET YARD
100' PROPOSED ROW
SLOPES
VARIES
2.5" S9.5B
74' EOP-EOP
COMPACTED
SUBGRADE
SCALE:
3
C2.0
TYPICAL STREET SECTION
NTS
CUL-DE-SAC
6'
SHOULDER
12'
SWALE
TIE TO EXISTING
3:1
3:1
6'
SHOULDER
12'
SWALE
SIGN
EASEMENT
STREET
LIGHTING
SCALE:
2
C2.0
TYPICAL STREET SECTION
NTS
RESIDENTIAL COLLECTOR
COMPACTED
SUBGRADE
3:1
3:1
TIE TO EXISTING
3:1
3:1
8"CABC
BASE
50' PUBLIC RIGHT OF WAY
20' PAVEMENT
10' LANE10' LANE
6'
SHOULDER
12'
SWALE
3:12%2%1"/FT
24"
6'
SHOULDER
12'
SWALE
LC RD.
2.5" S9.5B
3:
1
3:1
1"/FT
24"3:13:
1
1"/FT
24"3:13:1
3:1
3:11"/FT
24"
3:
1
EDGE OF
PAVEMENT
PROPERTY
BOUNDARY
20' PRIVATE
DRAINAGE EASEMENT
55' TO ℄
1:
11:11
:
11:130' DUKE POWER
EASEMENT
10' X 70' SDT
8"CABC
BASE
50'
20' PUBLIC UTILITY EASEMENT
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHEOHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE OHE OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
MAG NAIL
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP
W/V
FH FOMFOMFOMFOM
749.89 LF @ 0.22%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT WOODALL JR &
LANDA KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
ZONING: RA-30/COMM
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
1
20 1516171819
2 3 4 5 6
LOT
26,983 SQFT.
0.62 AC.
LOT
26,715 SQFT.
0.61 AC.
LOT
26,715 SQFT.
0.61 AC.
LOT
26,714 SQFT.
0.61 AC.
LOT
26,714 SQFT.
0.61 AC.
LOT
26,714 SQFT.
0.61 AC.
LOT
26,041 SQFT.
0.60 AC.
LOT
26,043 SQFT.
0.60 AC.
LOT
26,041 SQFT.
0.60 AC.
LOT
26,041 SQFT.
0.60 AC.
LOT
26,040 SQFT.
0.60 AC.
LOT
26,199 SQFT.
0.60 AC.43.25'54.40'54.88'56.30'19.20'58.76'254.43'16.33'
110.24'
41.
7
4
'
105.00'
105.00'254.43'105.00'
105.00'254.42'105.00'
105.00'254.42'105.00'
105.00'254.42'254.41'105.00'
105.00'248.01'105.00'
105.00'248.01'105.00'
49.35'55.67'248.01'105.00'
105.00'248.00'105.00'
105.00'248.00'105.00'
105.00'255.67'63.29'42.33'
105.00'
73.20'
105.00'263.23'2.70'33.14'21.7
6
'148.49'175.31'241.02'0.00'56.48'54.21'53.77'53.89'18.91'69.63'10+
0
0
11+
0
0
12+00 13+00 14+00 15+00 16+00 17+00
PC:
1
1
+
0
2
.
6
PT:12+25.9
L1
C1
L2
21
LOT
28,687 SQFT.
0.66 AC.
LOT
41,616 SQFT.
0.96 AC.53.31'33.64'8.64'30.
0
0
'
22
SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
CBU
ROADWAY CENTER LINE
RIGHT OF WAY LINE
LOT LINE
SETBACK LINE
SIGN
STREET LIGHT
CLUSTER MAILBOX UNIT
UTILITY/STORM EASEMENT
FENCE
LINE TABLE
NAME
L1
L2
ROADWAY
SAWYER MILL DRIVE
SAWYER MILL DRIVE
LENGTH
102.57'
791.66'
DIRECTION
N42°49'39"E
N12°44'55"E
BEGIN
STATION
10+00.00
12+25.94
END
STATION
11+02.57
20+17.61
CURVE TABLE
NAME
C1
ROADWAY
SAWYER MILL DRIVE
RADIUS
235.00'
ARC
LENGTH
123.37'
CHORD
LENGTH
121.96'
CHORD
DIRECTION
N27°47'17"E
BEGIN
STATION
11+02.57
END
STATION
12+25.94
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C2.1 PARTIAL SITE LAYOUT I.DWGPLOTTED: 8/1/2022 10:19 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
PARTIAL SITE LAYOUT I
1" = 40'
LEGEND:
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0 NEXISTING EOP
LOT 22 TO BE
CREATED VIA
RECOMBINATION
PLAT
25' ROW DEDICATION
30' STREETSCAPE BUFFER
30' STREET YARD
30' PUBLIC
UTILITY
EASEMENT
SIGN
EASEMENT
STREET
LIGHTING
EDGE OF
PAVEMENT
MATCHLINEREFER TO SHEET C2.250' ROW
20' EOP TO EOP
10' X 70'
SDT
10' X 70' SDT
55' TO ℄
30' DUKE
POWER
EASEMENT
R30'
R30'
R245'
R25'
R25'
STOP SIGN
5' PUBLIC UTILITY
EASEMENT
C2.1
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OHEOHESS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx
NC 55 E
(60' PUBLIC R/W)
EIS
EIS
MAG NAIL CP
PP PP PPPP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPGW
721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
TOP-219.39 MH
TOP-217.73
INV-207.19EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
11
10
12
13
9
1516
867
26,714 SQFT.
LOT
26,714 SQFT.
0.61 AC.
LOT
26,713 SQFT.
0.61 AC.
LOT
26,686 SQFT.
0.61 AC.
LOT
34,772 SQFT.
0.80 AC.
LOT
48,897 SQFT.
1.12 AC.
LOT
46,521 SQFT.
1.07 AC.
LOT
46,119 SQFT.
1.06 AC.
LOT
25,600 SQFT.
0.59 AC.
LOT
26,041 SQFT.
0.60 AC.
LOT
26,043 SQFT.
0.60 AC.254.42'254.41'105.00'
105.00'105.00'254.41'105.00'
105.00'248.97'16.81'89.43'
234.13'290.63'65.17'4.22'4
1
.
1
1
'
88.86'248.91'253.80'
37
3
.
6
2
'50.49'305.01'338.23'225.11'56.92'248.00'63.45'21.02
'
27.
5
0
'
105.00'248.00'105.00'
105.00'248.01'105.00'
105.00'
105.00'
49.35'55.67'
14
LOT
26,040 SQFT.
0.60 AC.
CBU
20+18
17+00 18+00 19+00 20+00SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
CBU
ROADWAY CENTER LINE
RIGHT OF WAY LINE
LOT LINE
SETBACK LINE
SIGN
STREET LIGHT
CLUSTER MAILBOX UNIT
UTILITY/STORM EASEMENT
FENCE
LINE TABLE
NAME
L1
L2
ROADWAY
SAWYER MILL DRIVE
SAWYER MILL DRIVE
LENGTH
102.57'
791.66'
DIRECTION
N42°49'39"E
N12°44'55"E
BEGIN
STATION
10+00.00
12+25.94
END
STATION
11+02.57
20+17.61
CURVE TABLE
NAME
C1
ROADWAY
SAWYER MILL DRIVE
RADIUS
235.00'
ARC
LENGTH
123.37'
CHORD
LENGTH
121.96'
CHORD
DIRECTION
N27°47'17"E
BEGIN
STATION
11+02.57
END
STATION
12+25.94
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C2.2 PARTIAL SITE LAYOUT II.DWGPLOTTED: 8/1/2022 10:19 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
PARTIAL SITE LAYOUT II
1" = 40'
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0 N25' ROW DEDICATION
30' STREETSCAPE BUFFER
STREET
LIGHTING
(TYP.)
CBU MAILBOX
KIOSK
EXISTING
TREELINE
EDGE OF
PAVEMENT
LEGEND:MATCHLINEREFER TO SHEET C2.120' PRIVATE
DRAINAGE EASEMENT
50' ROW20' EOP TO EOP 5' PUBLIC UTILITY
EASEMENT
100'
100'
100'
100'
R37'
R32.5'
R32.5'
R25'
R25'
R50'
C2.2
WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
BACKFLOW PREVENTER
W
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHE
OHE
OHE
OHE
OHE
OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
EIS
MAG NAIL CP
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP PP PP PP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPFOM
GW
FOM FOM
749.89 LF @ 0.22%721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
MH
TOP-217.73
INV-207.19
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT
WOODALL JR & LANDA
KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
1
11
10
12
13
9
20 1516171819
2 3 4 5 867
14
CBU
21
22 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHEOHEOHEOHE OHEOHEOHEWWWWWW
W W W W W W W W W
W W10+0011+0012+0013+0014+0014+77SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
SSMH#2
SSMH#3
SSMH#4
SSMH#5
SSMH#6
SSMH#7
DOG HOUSE
SSMH#1
C3.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C3.0 OVERALL UTILITY PLAN.DWGPLOTTED: 8/1/2022 10:20 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
OVERALL UTILITY PLAN
SCALE IN FEET
60'120'30'60'
SCALE: 1 IN = 60 FT
SCALE IN FEET
HORIZONTAL
0
LEGEND:N1" = 60'
GENERAL NOTES:
THE FOLLOWING NOTES ARE APPLICABLE TO UTILITY SHEETS C3.0 THRU C3.2
1.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS SHALL
BE PER HARNETT COUNTY STANDARDS AND SPECIFICATIONS.
2.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS SHALL
BE TO THE LATEST EDITION OF THE HARNETT COUNTY DEPT. OF PUBLIC UTILITIES
WATER & SEWER ORDINANCE AND THE UTILITY MASTER PLAN.
3.ALL WATER MAINS SHALL BE PUBLIC UTILITIES.
4.CONTRACTOR SHALL CONTACT HARNETT COUNTY UTILITIES PRIOR TO MAKING
CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE.
5.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER
EXTENSION PERMIT ISSUED BY NCDENR - PUBLIC WATER SUPPLY.
6.WATER MAINS SHALL BE ASTM D2241 SDR-21 PVC OR THICKNESS CLASS 50 DIP PUSH
ON JOINTS I.A.W. AWWA C151 WHERE NOTED.DUCTILE IRON PIPE WATER MAINS
SHALL BE CLASS 350 DIP I.A.W. AWWA C-151 WITH PUSH ON JOINTS I.A.W. AWWA
C-111. DIP SHALL BE CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS
MATERIAL I.A.W. AWWA C-104. ALL DIP BURIED PIPE SHALL HAVE AN BITUMINOUS
EXTERIOR COATING I.A.W. AWWA C-151. MINIMUM BURIAL DEPTH FOR WATER MAIN IS
36 INCHES BELOW FINISHED GRADE. ALL FITTINGS SHALL BE MECHANICAL JOINTS
I.A.W. AWWA C-111.
7.ALL WATER SERVICES TO LOTS SHALL BE 3/4" BLUE POLY TUBING W/TRACER WIRE.
MINIMUM BURIAL DEPTH FOR WATER SERVICES IS 24 INCHES.
8.SANITARY SEWER MAINS SHALL BE SDR-35 PVC I.A.W. ASTM D-3034-98 TYPE PSM OR
CLASS 250 DIP PUSH ON JOINTS I.A.W. AWWA C-150 AND C-151 WHEN NOTED. DIP
SHALL BE LINED WITH PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL.
8. ALL SANITARY SEWER SERVICES TO LOTS SHALL BE 4" SCH-40 PVC.
9.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY UTILITY
MUST BE ADJUSTED TO MEET SEPARATION REQUIREMENTS.
10.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH TRACER WIRE PER HARNETT
REGIONAL WATER STANDARDS.
11.PRIVATE UTILITIES (TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS
PLAN. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THOSE
UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
12.ELECTRICAL TRANSFORMERS SHALL NOT BE LOCATED WITHIN REQUIRED
LANDSCAPED BUFFERS.
13.ALL ELECTRICAL THROUGHOUT THE SUBDIVISION SHALL BE UNDERGROUND.
14.REFER TO C0.0 FOR HARNETT COUNTY PUBLIC UTILITIES REQUIRED NOTES.
15.ALL UTILITIES, INCLUDING FIRE HYDRANTS, INSTALLED OUTSIDE OF THE PROPOSED
ROW MUST BE IN A PUBLIC UTILITY EASEMENT.
EXISTING FIRE
HYDRANT
6" SDR-21 PVC
WATER LINE
FHA
EXISTING EDGE OF
PAVEMENT
FHA
FHA
30' DUKE
POWER
EASEMENT
20' PUBLIC UTILITY EASEMENT
30' STREET YARD
8" PVC SANITARY
SEWER LINE
RELOCATED
DUKE POWER
LINE
20' PRIVATE DRAINAGE
EASEMENT
5' PUBLIC UTILITY
EASEMENT
EXISTING WATER MAIN
WATER CONNECTION
WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
BACKFLOW PREVENTER
W
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHEOHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE OHE OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
MAG NAIL
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP
W/V
FH FOMFOMFOMFOM
749.89 LF @ 0.22%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT WOODALL JR &
LANDA KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
1
20 1516171819
2 3 4 5 6
10+
0
0
11+
0
0
12+00 13+00 14+00 15+00 16+00 17+00
21
22 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHEOHEOHEOHEOHEOHE OHEOHEOHEOHEWWWWWWWW
W
W W W W W W W W W W W10+0011+0012+0013+0014+0014+77SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
SSMH#6 - 4' DIA.
RIM: 221.87
INV. IN: 212.30
INV. OUT: 212.20
DOG HOUSE
SSMH#1 - 4' DIA.
RIM: 218.00
INV. IN: 206.71
INV. OUT: 204.37
SSMH#5 - 4' DIA.
RIM: 217.91
INV. IN: 210.22
INV. OUT: 210.12
SSMH#4 - 4' DIA.
RIM: 217.15
INV. IN: 209.74
INV. OUT: 209.64
SSMH#3 - 4' DIA.
RIM: 216.36
INV. IN: 209.25
INV. OUT: 209.02
SSMH#2 - 4' DIA.
RIM: 216.00
INV. IN: 208.70
INV. OUT: 208.60
396 LF 8" SDR35 PVC @ 0.50%
76 LF 8" SDR35 PVC @ 0.50%
78 LF 8" SDR35 PVC @ 0.50%
63 LF 8" SDR35 PVC @ 0.50%
378 LF 8" SDR35 PVC @ 0.50%
FHA
FHA
12"x6" TS&V w/ TB
(1) 6" GV
PROPOSED 6" SDR-21
PVC WATER MAIN
4" SANITARY SEWER
C/O & SERVICE, TYP.
3/4" WATER METER
& SERVICE, TYP.
COORDINATE NEW
RELOCATED
OVERHEAD LINES
WITH DUKE ENERGY
SIGN EASEMENT
EXIST.
WATER
METERS
EXIST. C/O 10'x30' BORE PIT W/ 1:1
SLOPES (TYP.)
10'x10' RECEIVING PIT
W/ 1:1 SLOPES (TYP.)
8" SDR35 PVC SEWER LINE &
62 LF OF 16" STEEL CASING
PIPE (t=0.25") BY BORE &
JACK. STEEL CASING TO BE
EXTENDED TO RIGHT OF WAY
20'x36' TEMPORARY
CONSTRUCTION
EASEMENT
C3.1
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C3.1 PARTIAL UTILITY PLAN I.DWGPLOTTED: 8/1/2022 10:20 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
PARTIAL UTILITY PLAN I
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
LEGEND:N1" = 40'
20' PUBLIC UTILITY EASEMENT
30' DUKE
POWER
EASEMENT
30'
STREET
YARD
6' OFFSET EOP,
TYP.MATCHLINEREFER TO SHEET C3.2EXIST. 12" WATER MAIN
EXIST. 8" SANITARY
SEWER LINE
20' HRW EASEMENT
50'
WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
BACKFLOW PREVENTER
W
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OHEOHESS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx
NC 55 E
(60' PUBLIC R/W)
EIS
EIS
MAG NAIL CP
PP PP PPPP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPGW
721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
TOP-219.39 MH
TOP-217.73
INV-207.19EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
11
10
12
13
9
1516
867
14
CBU
20+18
17+00 18+00 19+00 20+00
SSSSSSSSSSSSSSSSSSSSW W W W W W
W W WSAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
SSMH#6 - 4' DIA.
RIM: 221.87
INV. IN: 212.30
INV. OUT: 212.20
SSMH#7 - 5' DIA.
RIM: 220.30
INV. OUT: 214.28
395 LF 8" SDR35 PVC @ 0.50%
FHA
4" SANITARY SEWER
C/O & SERVICE, TYP.
3/4" WATER METER
& SERVICE, TYP.
PROPOSED 6" SDR-21
PVC WATER MAIN
5' PUBLIC UTILITY
EASEMENT
6"x2" REDUCER 2" VALVE
2" BOA
PROPOSED 2" SDR-21
PVC WATER MAIN
C3.2
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C3.2 PARTIAL UTILITY PLAN II.DWGPLOTTED: 8/1/2022 10:20 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
PARTIAL UTILITY PLAN II
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
LEGEND:N1" = 40'
20' PRIVATE DRAINAGE EASEMENTMATCHLINEREFER TO SHEET C2.1
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHE
OHE
OHE
OHE
OHE
OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
EIS
MAG NAIL CP
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP PP PP PP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPFOM
GW
FOM FOM217216215218219220221 220
221
222
219220221222220219
220221
220
217
749.89 LF @ 0.22%721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
MH
TOP-217.73
INV-207.19
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT
WOODALL JR & LANDA
KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
219
220
22
1
1
11
10
12
13
9
20 1516171819
2 3 4 5 867
14
CBU
21
22 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSMH#2SS
DOG HOUSE
SSMH#1SSSSSSSSSSSSOHEOHEOHEOHEOHEOHE OHEWWWWWW
W W W W W W W W W
W W10+0011+0012+0013+0014+0014+77SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
220220
220220
220
220
220 220
220
FES#100
SDMH#101
HDWL#102
63 LF 24" RCP @ 0.60%
3:1 SLOPE 3:1 SLOPE
FLOW DIRECTION
MAJOR CONTOUR
MINOR CONTOUR
INTERMEDIATE CONTOUR
RIP-RAP OUTLET PROTECTION
STORM DRAIN LINE
FLARED END SECTION
CATCH BASIN
4.0%
SW=295.40
FG =295.32 SPOT ELEVATION
400
C4.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C4.0 OVERALL GRADING AND DRAINAGE PLAN.DWGPLOTTED: 8/1/2022 10:21 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
OVERALL GRADING AND DRAINAGE PLAN
SCALE IN FEET
60'120'30'60'
SCALE: 1 IN = 60 FT
SCALE IN FEET
HORIZONTAL
0 N1" = 60'
LEGEND:
GENERAL NOTES:
1.BEFORE YOU DIG, STOP. CALL THE NC ONE-CALL CENTER AT 1-800-632-4949. IT'S THE LAW. EXISTING UTILITIES
ARE SHOWN FROM THE BEST AVAILABLE INFORMATION AND ARE APPROXIMATE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THESE AND OTHER UTILITIES BEFORE STARTING CONSTRUCTION. NOTIFY UTILITY
LOCATING COMPANY (ONE CALL @ 1-800-632-4949) OR INDIVIDUAL UTILITY OWNERS FOR UNDERGROUND
LOCATIONS AT LEAST 48 HOURS IN ADVANCE.
2.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS SHALL BE TO NCDOT STANDARDS
AND SPECIFICATIONS.
3.PRIVATE UTILITIES (POWER, TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS PLAN. THE
CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THOSE UTILITIES WHEN INSTALLING STORM DRAINAGE
TO AVOID CONFLICTS.
4.CUT/FILL SLOPES SHALL BE GRADED AT A MAXIMUM OF 3H:1V UNLESS OTHERWISE INDICATED. SLOPES
INDICATED TO BE STEEPER THAN 3:1 BUT EQUAL TO OR LESS THAN 2:1 SHALL BE PROVIDED WITH A PERMANENT
TURF REINFORCEMENT MAT (ACF ENVIRONMENTAL ECP-2 10 OZ OR APPROVED EQUAL).
5.NO GRADING EQUIPMENT SHALL BE PERMITTED ON-SITE UNTIL A LAND DISTURBANCE PERMIT HAS BEEN ISSUED
BY NCDENR.
6.ALL RIP-RAP IS TO BE INSTALLED WITH NON-WOVEN FILTER FABRIC BENEATH (MIRAFI 140N OR APPROVED EQUAL).
7.WHERE PROPOSED EDGE OF PAVEMENT CONNECTS TO EXISTING, CONTRACTOR SHALL MATCH EXISTING
ELEVATION AND CREATE A SMOOTH TRANSITION.
8.INSTALL A COIR LINING IN THE TDD'S IMMEDIATELY AFTER INSTALLATION IN ORDER TO MINIMIZE EROSION AND
PROVIDE A STABLE DITCH LINING. SEED AND MULCH THE DITCH IMMEDIATELY UPON INSTALLATION.
20' PRIVATE DRAINAGE EASEMENT
LANDSCAPE
BERM
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHEOHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE OHE OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
MAG NAIL
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP
W/V
FH FOMFOMFOMFOM21721621521821922022122
0
221
222
217
749.89 LF @ 0.22%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT WOODALL JR &
LANDA KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
ZONING: RA-30/COMM
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
1
20 1516171819
2 3 4 5 6
10+
0
0
11+
0
0
12+00 13+00 14+00 15+00 16+00 17+00
21
22 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSMH#2SS
DOG HOUSE
SSMH#1SSSSSSSSSSSSSSSSSSSSOHEOHEOHEOHEOHEOHEOHEOHE OHEOHEWWWWWWWW
W
W W W W W W W W W W W10+0011+0012+0013+0014+0014+77SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W 222221219218
217
216
220
221
221
221
218 217
219
216
219218
217216
216 220
220
FES#104
70 LF 18" RCP @ 1.00%
YI#103
INSTALL NEW NCDOT YI
OVER EXISTING 24" RCP.
CONNECT NEW 18" RCP
AND EXISTING 18" RCP
INTO NEW STRUCTURE.
FLOW DIRECTION
MAJOR CONTOUR
MINOR CONTOUR
INTERMEDIATE CONTOUR
RIP-RAP OUTLET PROTECTION
STORM DRAIN LINE
FLARED END SECTION
CATCH BASIN
4.0%
SW=295.40
FG =295.32 SPOT ELEVATION
400
STORM DRAINAGE TABLE
INLET#
100
101
102
103
104
TYPE
FES
SDMH
HDWL
YI
FES
ROADWAY
NONE.
NONE.
NONE.
NONE.
NONE.
RIM ELEV
(EOP)
217.33
220.00
219.93
214.00
213.74
INV IN (SLOPE)
(FROM-SIZE)
215.00 (0.60%)
(101-24")
215.48 (0.50%)
(102-24")
211.25 (1.00%)
(104-18")
INV OUT (SLOPE)
(TO-SIZE)
215.38 (0.60%)
(100-24")
217.18 (0.50%)
(101-24")
211.95 (1.00%)
(103-18")
C4.1
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C4.1 PARTIAL GRADING AND DRAINAGE PLAN I.DWGPLOTTED: 8/1/2022 10:21 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
PARTIAL GRADING AND DRAINAGE PLAN I
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0 N1" = 40'
LEGEND:MATCHLINEREFER TO SHEET C4.23:1 SLOPE
3:1 SLOPE
LANDSCAPE
BERM
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OHEOHESS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx
NC 55 E
(60' PUBLIC R/W)
EIS
EIS
MAG NAIL CP
PP PP PPPP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPGW
222
219220221222220219
220221
220
721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
TOP-219.39 MH
TOP-217.73
INV-207.19EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
219
220
2
2
1
11
10
12
13
9
1516
867
14
CBU
SSSSSSSSSSSSSSSSSSSSW W W W W W
W W WSAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W
221222222
219 218 218219220220
220220
221
221
221
220
220
3:1 SLOPE
3:1 SLOPE
HDWL#102
339 LF 24" RCP @ 0.50%
SDMH#101
FES#100
20' PRIVATE
DRAINAGE
EASEMENT
NCDOT CL 'B' RIP
RAP OVER MIRAFI
140N LINER
FLOW DIRECTION
MAJOR CONTOUR
MINOR CONTOUR
INTERMEDIATE CONTOUR
RIP-RAP OUTLET PROTECTION
STORM DRAIN LINE
FLARED END SECTION
CATCH BASIN
4.0%
SW=295.40
FG =295.32 SPOT ELEVATION
400
STORM DRAINAGE TABLE
INLET#
100
101
102
103
104
TYPE
FES
SDMH
HDWL
YI
FES
ROADWAY
NONE.
NONE.
NONE.
NONE.
NONE.
RIM ELEV
(EOP)
217.33
220.00
219.93
214.00
213.74
INV IN (SLOPE)
(FROM-SIZE)
215.00 (0.60%)
(101-24")
215.48 (0.50%)
(102-24")
211.25 (1.00%)
(104-18")
INV OUT (SLOPE)
(TO-SIZE)
215.38 (0.60%)
(100-24")
217.18 (0.50%)
(101-24")
211.95 (1.00%)
(103-18")
C4.2
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C4.2 PARTIAL GRADING AND DRAINAGE PLAN II.DWGPLOTTED: 8/1/2022 10:21 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
PARTIAL GRADING AND DRAINAGE PLAN II
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0 N1" = 40'
LEGEND:MATCHLINEREFER TO SHEET C4.1LANDSCAPE
BERM
WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
BACKFLOW PREVENTER
WPROSPECT CHURCH ROAD(60' PUBLIC R/W)24"
R
C
P
18" RCP15" RCPDAVIS BRYANT WOODALL JR &
LANDA KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 213.80
10+
0
0
11+
0
0
12+00 13+00 14+00 15+00 16+00
PC:
1
1
+
0
2
.
6
PT:12+25.9
L1
C1
L2
SAWYER MILL DRIVE50' PUBLIC AND UTILITY R/W SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHEOHEOHEOHEWWWW
W
W W W W W W W W10+0011+0012+0020' PUBLIC
UTILITY
EASEMENT
30' DUKE
POWER
EASEMENT
30'
STREET
YARD
EDGE OF PAVEMENT
FHA
8" SANITARY SEWER LINE
6" WATER LINEDUKE POWER LINE
FHA
PROPERTY BOUNDARY
SSMH#5
SSMH#4
SSMH#3
SSMH#2
205
210
215
220
225
230
205
210
215
220
225
230
9+75()10+00(215.52)215.5510+50(215.26)216.1511+00(216.12)216.6511+50(217.30)217.1512+00(218.69)217.6512+50(219.90)218.1513+00(220.59)218.6513+50(220.69)219.1514+00(220.82)219.6514+50(220.97)220.1515+00(221.14)220.652.03%
1.00%
396 LF 8" SDR35 PVC @ 0.50%STA: 12+25.94TOP: 217.91INV IN: 210.22 (6)INV OUT: 210.12 (4)54' DIASSMH76 LF 8" SDR35 PVC @ 0.50%STA: 11+50TOP: 217.15INV IN: 209.74 (5)INV OUT: 209.64 (3)44' DIASSMH78 LF 8" SDR35 PVC @ 0.50%STA: 10+71.38TOP: 216.36INV IN: 209.25 (4)INV OUT: 209.02 (2)34' DIASSMH36" MIN, TYP
EXISTING GROUND
FINISHED GRADE
6" 45° ELBOW
W/ TB
PROPOSED 6"
SDR-21 PVC
WATER MAIN
WATER PROFILE
CONTINUES ON
SS WATER MAIN
PROFILE VIEW
LINE TABLE
NAME
L1
L2
ROADWAY
SAWYER MILL DRIVE
SAWYER MILL DRIVE
LENGTH
102.57'
791.66'
DIRECTION
N42°49'39"E
N12°44'55"E
BEGIN
STATION
10+00.00
12+25.94
END
STATION
11+02.57
20+17.61
CURVE TABLE
NAME
C1
ROADWAY
SAWYER MILL DRIVE
RADIUS
235.00'
ARC
LENGTH
123.37'
CHORD
LENGTH
121.96'
CHORD
DIRECTION
N27°47'17"E
BEGIN
STATION
11+02.57
END
STATION
12+25.94
C5.1.1
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C5.1.1 SAWYER DRIVE PLAN AND PROFILE I.DWGPLOTTED: 8/1/2022 10:22 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
SAWYER DRIVE PLAN AND PROFILE I
LEGEND:
1" = 40'
1.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS
SHALL BE TO NCDOT STANDARDS AND SPECIFICATIONS.
2.ALL WATER MAINS AND SANITARY SEWER MAINS SHALL BE PUBLIC UTILITIES.
3.CONTRACTOR SHALL CONTACT HARNETT COUNTY PRIOR TO MAKING
CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE.
4.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER
EXTENSION PERMIT ISSUED BY NCDENR PUBLIC WATER SUPPLY.
5.ALL STORM DRAINAGE PIPE SHALL BE CLASS III RCP UNLESS OTHERWISE
NOTED.
6.WATER MAINS SHALL BE ASTM D2241 SDR-21 PVC OR THICKNESS CLASS 50
DIP PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE
CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W.
AWWA C104. ALL WATER SERVICES TO LOTS SHALL BE 3/4" TYPE "K" SOFT
COPPER.
7.SANITARY SEWER MAINS SHALL BE SDR-35 PVC OR THICKNESS CLASS 50 DIP
PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE LINED WITH
PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL. ALL SANITARY SEWER
SERVICES TO LOTS SHALL BE 4" SDR-35 PVC. DUCTILE IRON PIPE SHALL BE
USED FOR SANITARY SEWER SERVICES WITH LESS THAN 3 FEET OF COVER
OR IN EXCESS OF 20 FEET OF COVER. DUCTILE IRON SERVICES SHALL ALSO
BE USED IN ALL CASES WHERE A WELL IS LOCATED WITHIN 100 FEET OF THE
SEWER SERVICE LINE.
8.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY
UTILITY MUST BE ADJUSTED TO MEET SEPARATION REQUIREMENTS.
9.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH ELECTRIC MARKER
SYSTEM BALLS PER HARNETT COUNTY STANDARDS.
10.PRIVATE UTILITIES (POWER, TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT
SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
11.WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING
OR PROPOSED SANITARY SEWERS UNLESS THE ELEVATION OF THE BOTTOM
OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE
SANITARY SEWER WITH A HORIZONTAL DISTANCE OF AT LEAST 3 FEET.
12.VERTICAL SEPARATION DISTANCE SHALL BE 24 INCHES MINIMUM BETWEEN
SANITARY SEWER AND STORM SEWER LINES. VERTICAL SEPARATION
DISTANCE SHALL BE 18 INCHES MINIMUM BETWEEN WATER AND SANITARY
SEWER AND 12 INCHES BETWEEN WATER AND STORM SEWER LINES.
13.ALL MANHOLES, CLEANOUTS, VALVES, METERS, AND OTHER AT OR ABOVE
GRADE APPURTENANCES SHALL NOT BE INSTALLED IN SIDEWALKS.
NOTES:N40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
SCALE:
1
C5.1.1
STATION 10+00-15+00
1" = 40'
SAWYER DRIVE PLAN VIEW
SCALE:
2
C5.1.1
STATION 10+00-15+00
H - 1" = 40' V - 1" = 4'
SAWYER DRIVE PROFILE VIEW
SCALE IN FEET
0
4'SCALE:1"=4'VERTICALMATCHLINEREFER TO SHEET C5.1.2
WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
BACKFLOW PREVENTER
W
11
10
CBU
20+18
15+00 16+00 17+00 18+00 19+00 20+00L2
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSW W W W W W W W W
W W WEDGE OF PAVEMENT
FHA
8" SANITARY SEWER LINE
6" WATER LINE
20' PRIVATE DRAINAGE EASEMENT
10' SEPARATION
FHA
SSMH#7SSMH#6
210
215
220
225
230
235
210
215
220
225
230
235
15+00(221.14)220.6515+50(221.04)221.1516+00(221.08)221.6516+50(220.93)222.1517+00(220.36)222.5817+50(219.68)222.6918+00(219.01)222.4718+50(218.73)221.9819+00(218.55)221.4819+50(218.71)220.9820+00(218.70)220.4820+50()20+75()HIGH PT STA: 17+41.82
HIGH PT ELEV: 222.69
PVI STA: 17+42.00
PVI ELEV: 223.07
K: 74.83
LVC: 150.00
PVC: 16+67.00ELEV: 222.32PVT: 18+17.00ELEV: 222.321.00%STA: 20+17.61TOP: 220.30INV OUT: 214.28 (6)75' DIASSMH395 LF 8" SDR35 PVC @ 0.50%STA: 16+22.32TOP: 221.87INV IN: 212.30 (7)INV OUT: 212.20 (5)64' DIASSMH36" MIN, TYP
EXISTING GROUND FINISHED GRADE
FHA
(6" PVC)
PROPOSED 6"
SDR-21 PVC
WATER MAIN
6"x2"
REDUCER
2" GV
2"PVC WILL CONTINUE
AROUND CDS AS
SHOWN ON PLAN VIEW
2" PVC
LINE TABLE
NAME
L1
L2
ROADWAY
SAWYER MILL DRIVE
SAWYER MILL DRIVE
LENGTH
102.57'
791.66'
DIRECTION
N42°49'39"E
N12°44'55"E
BEGIN
STATION
10+00.00
12+25.94
END
STATION
11+02.57
20+17.61
CURVE TABLE
NAME
C1
ROADWAY
SAWYER MILL DRIVE
RADIUS
235.00'
ARC
LENGTH
123.37'
CHORD
LENGTH
121.96'
CHORD
DIRECTION
N27°47'17"E
BEGIN
STATION
11+02.57
END
STATION
12+25.94
C5.1.2
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C5.1.2 SAWYER DRIVE PLAN AND PROFILE II.DWGPLOTTED: 8/1/2022 10:22 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
SAWYER DRIVE PLAN AND PROFILE II
LEGEND:
1" = 40'N40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
SCALE:
1
C5.1.2
STATION 15+00-20+08
1" = 40'
SAWYER DRIVE PLAN VIEW
SCALE:
2
C5.1.2
STATION 15+00-20+08
H - 1" = 40' V - 1" = 4'
SAWYER DRIVE PROFILE VIEW
SCALE IN FEET
0
4'SCALE:1"=4'VERTICALMATCHLINEREFER TO SHEET C5.1.11.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS
SHALL BE TO NCDOT STANDARDS AND SPECIFICATIONS.
2.ALL WATER MAINS AND SANITARY SEWER MAINS SHALL BE PUBLIC UTILITIES.
3.CONTRACTOR SHALL CONTACT HARNETT COUNTY PRIOR TO MAKING
CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE.
4.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER
EXTENSION PERMIT ISSUED BY NCDENR PUBLIC WATER SUPPLY.
5.ALL STORM DRAINAGE PIPE SHALL BE CLASS III RCP UNLESS OTHERWISE
NOTED.
6.WATER MAINS SHALL BE ASTM D2241 SDR-21 PVC OR THICKNESS CLASS 50
DIP PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE
CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W.
AWWA C104. ALL WATER SERVICES TO LOTS SHALL BE 3/4" TYPE "K" SOFT
COPPER.
7.SANITARY SEWER MAINS SHALL BE SDR-35 PVC OR THICKNESS CLASS 50 DIP
PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE LINED WITH
PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL. ALL SANITARY SEWER
SERVICES TO LOTS SHALL BE 4" SDR-35 PVC. DUCTILE IRON PIPE SHALL BE
USED FOR SANITARY SEWER SERVICES WITH LESS THAN 3 FEET OF COVER
OR IN EXCESS OF 20 FEET OF COVER. DUCTILE IRON SERVICES SHALL ALSO
BE USED IN ALL CASES WHERE A WELL IS LOCATED WITHIN 100 FEET OF THE
SEWER SERVICE LINE.
8.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY
UTILITY MUST BE ADJUSTED TO MEET SEPARATION REQUIREMENTS.
9.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH ELECTRIC MARKER
SYSTEM BALLS PER HARNETT COUNTY STANDARDS.
10.PRIVATE UTILITIES (POWER, TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT
SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
11.WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING
OR PROPOSED SANITARY SEWERS UNLESS THE ELEVATION OF THE BOTTOM
OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE
SANITARY SEWER WITH A HORIZONTAL DISTANCE OF AT LEAST 3 FEET.
12.VERTICAL SEPARATION DISTANCE SHALL BE 24 INCHES MINIMUM BETWEEN
SANITARY SEWER AND STORM SEWER LINES. VERTICAL SEPARATION
DISTANCE SHALL BE 18 INCHES MINIMUM BETWEEN WATER AND SANITARY
SEWER AND 12 INCHES BETWEEN WATER AND STORM SEWER LINES.
13.ALL MANHOLES, CLEANOUTS, VALVES, METERS, AND OTHER AT OR ABOVE
GRADE APPURTENANCES SHALL NOT BE INSTALLED IN SIDEWALKS.
NOTES:
WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
BACKFLOW PREVENTER
W
OH
E
OHE
OHEOHE
OHEOHEOHEOHEOHEOHEOHESSxSSxSSxSSxSSGxGxGxGxGxGxPR
O
S
P
E
C
T
C
H
U
R
C
H
R
O
A
D
(60'
P
U
B
L
I
C
R
/
W
)CP24" RCP18
"
R
C
P
15"
R
C
P
GRAVEL/SOIL DRIVEW/MW/MC/OSHELTERPPPPPPFOMFOMWxWxWxWxWxWxMHTOP-217.29INV-204.17APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINEBLOCKHOUSEDAVIS BRYANT WOODALL JR &LANDA KAY WOODALL CAPPS D.B.3269, PG.0007ZONING: RA-20MUSE: RESIDENTIALINV: 211.08INV: 211.59INV: 212.08INV: 212.00INV: 214.07INV: 213.8010+0011+00PC:11+02.6L121
22
SSSSMH#2
SSDOG HOUSE
SSMH#1 SSSSSSSSSSSSSSSSSSSSOHEOHE OHE OHE
OH
E
OH
E
OH
E
OH
E
OH
E
10+00 11+00 12+00 13+00
14+
0
0
14+
3
6WWWWWWW
WW10+
0
0
11+
0
0
12
+
0
0
13+
0
0
14+
0
0
14+77
30' DUKE POWER EASEMENT
20' PUBLIC UTILITY EASEMENT
8" SANITARY SEWER LINE
6" WATER LINE
FHA
STREET LIGHTINGEDGE OF
PAVEMENT
DUKE POWER LINE PROPERTY BOUNDARY
SIGN EASEMENT
TEMP. BOA
10'X30' BORE PIT
(TYPICAL 1:1 SLOPE)
10'X10' RECEIVING PIT
(TYPICAL 1:1 SLOPE)
TEMPORARY
CONSTRUCTION
EASEMENT
EDGE OF
PAVEMENT
8" PVC SEWER MAIN W/ 62 LF
16" STEEL CASING PIPE TO BE
INSTALLED VIA JACK AND BORE
20' HRW EASEMENT
12"X6" TS&V
GAS LINE ELEVATION TO
BE FIELD VERIFIED.
WATER MAIN MUST
MAINTAIN 24" VERTICAL
SEPARATION FROM GAS
LINE. UTILIZE BACKSIDE
TAP OR ELBOWS IF
NECESSARY
200
205
210
215
220
225
230
200
205
210
215
220
225
230
9+75()10+00()10+50(216.87)11+00(217.64)11+50(218.02)12+00(217.73)12+50(217.19)13+00(216.20)13+50(215.41)14+00(215.29)14+50()14+75()378 LF 8" SDR35 PVC @ 0.50%STA: 10+00TOP: 218.00INV IN: 206.71 (2)14' DIASSMHSTA: 13+77.71TOP: 216.00INV IN: 208.70 (3)INV OUT: 208.60 (1)24' DIASSMH63 LF 8" SDR35 PVC @ 0.50%
EXISTING GROUND
FINISHED GRADE
4' DIA DOGHOUSE
MANHOLE ON EXISTING
SEWER MAIN (INV:203.72)
8" SDR35 PVC SEWER
LINE & 62 LF OF 16" STEEL
CASING PIPE (t=0.25") BY
BORE & JACK. STEEL
CASING TO BE EXTENDED
TO RIGHT OF WAY
BORE PIT
RECEIVING PIT
C5.2
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C5.2 SS OUTFALL PLAN AND PROFILE.DWGPLOTTED: 8/1/2022 10:23 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
SS OUTFALL PLAN AND PROFILE
LEGEND:
1" = 40'N40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
SCALE:
1
C5.2
STATION 10+00-14+50
1" = 40'
SS OUTFALL PLAN VIEW
SCALE:
2
C5.2
STATION 10+00-14+50
H - 1" = 40' V - 1" = 4'
SS OUTFALL PROFILE VIEW
SCALE IN FEET
0
4'SCALE:1"=4'VERTICAL
1.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS
SHALL BE TO NCDOT STANDARDS AND SPECIFICATIONS.
2.ALL WATER MAINS AND SANITARY SEWER MAINS SHALL BE PUBLIC UTILITIES.
3.CONTRACTOR SHALL CONTACT HARNETT COUNTY PRIOR TO MAKING
CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE.
4.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER
EXTENSION PERMIT ISSUED BY NCDENR PUBLIC WATER SUPPLY.
5.ALL STORM DRAINAGE PIPE SHALL BE CLASS III RCP UNLESS OTHERWISE
NOTED.
6.WATER MAINS SHALL BE ASTM D2241 SDR-21 PVC OR THICKNESS CLASS 50
DIP PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE
CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W.
AWWA C104. ALL WATER SERVICES TO LOTS SHALL BE 3/4" TYPE "K" SOFT
COPPER.
7.SANITARY SEWER MAINS SHALL BE SDR-35 PVC OR THICKNESS CLASS 50 DIP
PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE LINED WITH
PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL. ALL SANITARY SEWER
SERVICES TO LOTS SHALL BE 4" SDR-35 PVC. DUCTILE IRON PIPE SHALL BE
USED FOR SANITARY SEWER SERVICES WITH LESS THAN 3 FEET OF COVER
OR IN EXCESS OF 20 FEET OF COVER. DUCTILE IRON SERVICES SHALL ALSO
BE USED IN ALL CASES WHERE A WELL IS LOCATED WITHIN 100 FEET OF THE
SEWER SERVICE LINE.
8.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY
UTILITY MUST BE ADJUSTED TO MEET SEPARATION REQUIREMENTS.
9.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH ELECTRIC MARKER
SYSTEM BALLS PER HARNETT COUNTY STANDARDS.
10.PRIVATE UTILITIES (POWER, TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT
SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
11.WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING
OR PROPOSED SANITARY SEWERS UNLESS THE ELEVATION OF THE BOTTOM
OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE
SANITARY SEWER WITH A HORIZONTAL DISTANCE OF AT LEAST 3 FEET.
12.VERTICAL SEPARATION DISTANCE SHALL BE 24 INCHES MINIMUM BETWEEN
SANITARY SEWER AND STORM SEWER LINES. VERTICAL SEPARATION
DISTANCE SHALL BE 18 INCHES MINIMUM BETWEEN WATER AND SANITARY
SEWER AND 12 INCHES BETWEEN WATER AND STORM SEWER LINES.
13.ALL MANHOLES, CLEANOUTS, VALVES, METERS, AND OTHER AT OR ABOVE
GRADE APPURTENANCES SHALL NOT BE INSTALLED IN SIDEWALKS.
NOTES:
WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
BACKFLOW PREVENTER
W
205
210
215
220
225
205
210
215
220
225
10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+25
36" MIN, TYP
12x6" TS&V W/
(1) 6" GV
6" BEND W/
TB
EXISTING GROUND
PROPOSED 6"
SDR-21 PVC
WATER MAIN
6" 45° ELBOW
W/ TB
6" 45° ELBOW
W/ TBWATER PROFILE
CONTINUES ON
SAWYER DRIVE
PROFILE VIEW
36" CLEARANCE, TYP
6" 45° ELBOW
W/ TB
GAS LINE ELEVATION TO BE
FIELD VERIFIED. WATER MAIN
MUST MAINTAIN 24" VERTICAL
SEPARATION FROM GAS LINE.
UTILIZE BACKSIDE TAP OR
ELBOWS IF NECESSARY OHEOHEOHEOHEOHEOHEOHEOHESSxSSxSSxGxGxGxGxGxN 42°57'51"W 622.35'N 60°53'53"W 128.41'MAG NAILCP24" RCP18" RCP15" RCPGRAVEL/SOIL DRIVEW/MW/MC/OSHELTERPPPPPPFOMWxWxWxWxWxWMHTOP-217.29INV-204.17APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINEBLOCKHOUSEINV: 211.59INV: 212.08INV: 212.00INV: 214.07INV: 213.801
10+0011+0012+00PC:11+02.6L1C121
22SSSS
SSMH#2
SS
SS
SS
SS
SS
SS
SS
SS
OHEOHEOHEOHEOHEOHEOHEOHE12+00
13+00
14+0014+36
W W W W W W WWWW
10+00 11+00 12+00 13+00 14+00
14+7
7
6" WATER LINE
PROPERTY BOUNDARY5' SEPARATION OF
WATER LINE FROM
RIGHT-OF-WAY
12"X6" TS&V
(1) 6" GV
WATER MUST MAINTAIN 24"
VERTICAL SEPARATION FROM
GAS LINE AND WATER
CONNECTION WILL UTILIZE
BACKSIDE TAP IF
NECESSARY
DUKE POWER LINE
SANITARY SEWER
C5.3
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C5.3 WATER MAIN PLAN AND PROFILE.DWGPLOTTED: 8/1/2022 10:23 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
WATER MAIN PLAN AND PROFILE
LEGEND:
1" = 40'
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
SCALE:
2
C5.3
STATION 10+00-15+25
H - 1" = 40' V - 1" = 4'
PROSPECT CHURCH WATER MAIN PROFILE
SCALE IN FEET
0
4'SCALE:1"=4'VERTICAL
1.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS
SHALL BE TO NCDOT STANDARDS AND SPECIFICATIONS.
2.ALL WATER MAINS AND SANITARY SEWER MAINS SHALL BE PUBLIC UTILITIES.
3.CONTRACTOR SHALL CONTACT HARNETT COUNTY PRIOR TO MAKING
CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE.
4.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER
EXTENSION PERMIT ISSUED BY NCDENR PUBLIC WATER SUPPLY.
5.ALL STORM DRAINAGE PIPE SHALL BE CLASS III RCP UNLESS OTHERWISE
NOTED.
6.WATER MAINS SHALL BE ASTM D2241 SDR-21 PVC OR THICKNESS CLASS 50
DIP PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE
CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W.
AWWA C104. ALL WATER SERVICES TO LOTS SHALL BE 3/4" TYPE "K" SOFT
COPPER.
7.SANITARY SEWER MAINS SHALL BE SDR-35 PVC OR THICKNESS CLASS 50 DIP
PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED. DIP SHALL BE LINED WITH
PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL. ALL SANITARY SEWER
SERVICES TO LOTS SHALL BE 4" SDR-35 PVC. DUCTILE IRON PIPE SHALL BE
USED FOR SANITARY SEWER SERVICES WITH LESS THAN 3 FEET OF COVER
OR IN EXCESS OF 20 FEET OF COVER. DUCTILE IRON SERVICES SHALL ALSO
BE USED IN ALL CASES WHERE A WELL IS LOCATED WITHIN 100 FEET OF THE
SEWER SERVICE LINE.
8.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY
UTILITY MUST BE ADJUSTED TO MEET SEPARATION REQUIREMENTS.
9.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH ELECTRIC MARKER
SYSTEM BALLS PER HARNETT COUNTY STANDARDS.
10.PRIVATE UTILITIES (POWER, TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT
SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
11.WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING
OR PROPOSED SANITARY SEWERS UNLESS THE ELEVATION OF THE BOTTOM
OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE
SANITARY SEWER WITH A HORIZONTAL DISTANCE OF AT LEAST 3 FEET.
12.VERTICAL SEPARATION DISTANCE SHALL BE 24 INCHES MINIMUM BETWEEN
SANITARY SEWER AND STORM SEWER LINES. VERTICAL SEPARATION
DISTANCE SHALL BE 18 INCHES MINIMUM BETWEEN WATER AND SANITARY
SEWER AND 12 INCHES BETWEEN WATER AND STORM SEWER LINES.
13.ALL MANHOLES, CLEANOUTS, VALVES, METERS, AND OTHER AT OR ABOVE
GRADE APPURTENANCES SHALL NOT BE INSTALLED IN SIDEWALKS.
NOTES:NSCALE:
1
C5.3
STATION 10+00-15+25
1" = 40'
PROSPECT CHURCH WATER MAIN PLAN VIEW
PROSPECT CHURCH ROAD NC HWY
5
5
C6.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C6.0 SITE DETAILS.DWGPLOTTED: 8/1/2022 10:23 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
SITE DETAILS
SPACER
RUBBER
12"
6"
4"
4"
47 1/4"48 3/16"
62 9/16"
17 7/8"
61 5/8"
17" PEDESTAL
10"
12"
14 3/8"
10"
16 5/8"
1P
6
8
7
5
4
3
2
1
OUTGOING MAIL
11
30 1/4"
12 7/8"
30 1/2"
3 1/4""
14
13
12
15
16
17
18
4"
2P
9
10 19
SCALE:
1
C6.0
CLUSTER MAIL BOX
NTS
NOTES:
1.MULTIPLE UNIT BOXES MAY BE NEEDED
TO SUPPLY NUMBER OF UNITS
2. COLOR: BLACK
30"30"R1-1
NOTE: REFER TO SIGN BASE DETAIL THIS
SHEET FOR ADDITIONAL INFO AND
INSTALLATION DETAILS
SCALE:
2
C6.0
STOP SIGN
NTS
SCALE:
3
C6.0
CONCRETE DROP INLET
NTS SCALE:
4
C6.0
DROP INLET FRAME & GRATE
NTS
C6.1
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C6.1 WATER DETAILS I.DWGPLOTTED: 8/1/2022 10:24 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
WATER DETAILS I2" "I-2" ASP. PAV'T.(PAVEMENT PATCH)12" 12"3'-0" MI. COVEREXIST.
PAV'T.
SAW CUT EXIST. PAVEMENT
EXIST. PAV'T.
NEW
PIPE
PIPE O.D. PLUS 18" FOR PIPES UNDER 33" O.D.
PIPE O.D. PLUS 24" FOR PIPES OVER 33" O.D.
10" STONE MEETING N.C.D.O.T. SPECIFICATIONS
FOR A.B.C. STONE, TYPE B OR C, TO BE
COMPACTED TO 100 % MAXIMUM DRY DENSITY
NOTES:
1. PAVEMENT SHALL BE CUT TO TRUE LINE AND
REMOVED BEFORE TRENCH IS CUT.
2. STONE AND PAVEMENT TO BE PLACED WITH LEAST
INTERFERENCE TO TRAFFIC.
3. STABILIZED AGGREGATE TO BE SECURED FROM AN
APPROVED QUARRY.
4. ALL PAVEMENT REPAIRS TO BE IN ACCORDANCE
WITH N.C.D.O.T. SPECIFICATIONS.
COMPACTED BACKFILL
NO SCALE
TYPICAL TRENCH IN BITUMINOUS SURFACE AREAS DETAIL W
10
PIPE BEDDED IN 4" MININUM
JOB EXCAVATED MATERIAL.
BACKFILL LIGHTLY CONSOLIDATED
TO TOP OF PIPE.
PIPE BEDDED IN SAND, GRANULAR
MATERIAL OR GRADED GRAVEL TO
THE DEPTH OF 1/8 PIPE DIAMETER,
4" MIN. JOB EXCAVATED MATERIAL
COMPACTED TO 4" ABOVE TOP OF PIPE.
(APPROX. 95% STANDARD PROCTOR,
AASHTO T-99)
ALL DUCTILE
IRON GRAVITY
SEWER LINE.
ALL PVC WATER
LINE AND PVC
FORCE MAIN.
TYPE 3
TYPE 4
NO SCALE
TYPICAL LAYING CONDITIONS DETAIL W
11
2 1/2" HOSE
CONNECTION
STEAMER
CONNECTION
CONC.1'-6"BURY AS SPECIFIEDON PLANS
AS SHOWN
1'-0"BLOCKING
(SEE NOTE)2'-6"WEEP HOLE TO
REMAIN OPEN
2'-0"
BACKFILL
STONE
(7 C.F. MIN.)
6" G.V. &
C. I. BOX
4-3/4" TIE RODS WITH BRACKETS
(SEE DETAIL)
6" HYDRANT TEE
6" WATER
LINE
NOTE:
1.)TIE HYDRANT TO MAIN LINE
W/TIE RODS IN LIEW OF CONC.
BLOCKING IN SANDY SOIL.
PRECAST CONCRETE
PROTECTION RING
NO SCALE
TYPICAL FIRE HYDRANT INSTALLATION DETAIL
EDGE
OF
ROAD
W
6
MASONRY BLOCK
2.)MECHANICAL JOINTS USED WITH GRIP RINGS OPENEXISTING WATER MAIN
NEW WATER MAIN
TAPPING VALVE
WITH VALVE BOX
NO SCALE
TYPICAL TAPPING SLEEVE AND VALVE ASSEMBLY DETAIL
TAPPING SLEEVE SHALL BE ROMAC BRAND
MODEL SST MANUFACTURED WITH 316
STAINLESS STEEL.
W
5
PE PLASTIC TO PROTECT
TAPPING SLEEVE
THRUST BLOCKING
WATERMAIN
STREET
PROPERTYLINEPROPERTYLINER/W
R/W
NO SCALE
TYPICAL DOMESTIC WATER SERVICE INSTALLATION DETAIL
SINGLE 3/4" SERVICES
2" PVC SLEEVE W/ 3/4" CARRIER
12" MIN
1. INSTALL METER AT R/W
2. "TWO (2)-3/4" SERVICE LINES MUST BE INSTALLED
INSIDE A 2" SLEEVE."
5. SEE DETAIL FOR SERVICE MATERIAL AND METER
SETTING
4. SLEEVES SHOULD BE SCHEDULE 40 PVC PIPE.
3. "TWO (2)-1" SERVICE LINES MUST BE INSTALLED
INSIDE A 3" SLEEVE."
1'
6. SERVICE LINE SHALL BE 3' BELOW FINISHED GRADE
OF DITCHES.
6'
METERS SHOULD BE
INSTALLED 3' OFF
PROPERTY LINE
W
12
7. CONDUIT MUST EXTEND PAST PREPOSED SIDEWALK.
SIDEWALK
ON THE THRUST BLOCKING SCHEDULE.
2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT
1. CONCRETE SHALL BE 3,000 PSI MIN.
12"
8"
6"6"
8"
8"8"
30"
24"
18"
16"
12"
20"
18"
16"
14"
12"
9"
16"
14"12"
8"
6"
16"
14"
8"
18"
16"
14"
10"
8"
10"
8"
8"
20"
14"
20"
10"
8"
16"
14"
12"
10"
PLUG11/4° BEND45° BEND
24" MIN. - 12" OR LESS
18" MIN. - 10" OR LESS
18" MIN.SQSQCB5. VOLUME OF THRUST BLOCKING SHALL BE AS SHOWN
BLOCKING.
WITH 10 MIL. POLYETHYLENE PRIOR TO POURING
4. ALL PIPING AND ACCESSORIES TO BE WRAPPED
3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS.
PART (BLOCKING AREA) AGAINST UNDISTURBED SOIL.
SHAPE MORE EASILY FORMED WITH THE WIDEST
FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE
NOTES:
10"
8"
6"
8"
6"
36"
34"
25"
20"
18"
16"
14"
12"
10"
10"
18"
11"
10"
10"
8"
16"
14"
10"
12"
10"
8"
6"
12"
10"
8"
12"
10"
16"
14"
12"
10"
18"
16"
13"
12"
12"
26"
22"
16"
15"8"
6"
4"
TEE221/2° BEND90° BEND
SIZE
PIPE DB45°
PLAN TEES
HYDRANT TEE
PLAN BENDS
X
X
6" MIN.
AA
X
X
A
A
6" MIN.
MIN.1/3 C.Y. AT 3000 P.S.I.
NO SCALE
TYPICAL THRUST BLOCK DETAIL W
7
A B A B A B A B C D A B
C6.2
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C6.2 WATER DETAILS II.DWGPLOTTED: 8/1/2022 10:24 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
WATER DETAILS II
2"
1"
FINISHED GRADE
21" TOTALADJUSTMENTVALVE BOX VALVE OPERATOR NUT
NO SCALE
TYPICAL VALVE BOX DETAIL
PROTECTION RING
PRECAST CONCRETE
BACKFILL TO EDGE
W
2
NOTE:
AT PIPE INTERSECTIONS, MULTIPLE
VALVES, RUN WIRE UP AT ONLY
ONE VALVE.
SINGLE 12 AWG SOLID CORE WIRE
GATE VALVE
TRACER WIRE TO BE LAID
UNDERNEATH WATER LINE
VALVE BOX
FINISHED GRADE
IN VALVE BOX
NO. 1
DRILL HOLE
FOR TRACER WIRE
TRACER WIRE
VALVE BOX
P.V.C. PIPELINE
NOTES:
1. DRILL HOLE IN VALVE BOX TO INSERT TRACER WIRE,BRING UP TO INSIDE AND ROLL UP AT LEAST 6"-8" EXCESS
VALVE BOX
2. PLACE TRACER WIRE IN VALVE BOX AT 1,000" INTERVALS OR AS NOTED ON THE PLANS, TYPICAL.
PLACE EMPTY VALVE BOX AT INTERVALS WHERE
VALVES DO NOT OCCUR & PLACE TRACER WIRE
IN BOX.
NO SCALE
TYPICAL TRACER WIRE INSTALLATION DETAIL
3. DO NOT SPLICE WIRE WHEN BEGINNING A NEW SPOOL. INSTEAD INSTALL A VALVE BOX AND ATTACH EACH WIRE WITH A
BRASS SCREW TO THE VALVE BOX.
NOTE:
LOOPED IN BOX
6"-8" EXCESS
PRECAST CONCRETE PROTECTION RING
BACKFILL TO EDGE
W
3
MASONRY BLOCK
P.R.V. Location down stream of the cut-off valve
METER SETTER
CENTERED
IN BOX 18" MIMINUM COVERNO SCALE
TYPICAL 3/4" METER SETTER INSTALLATION DETAIL
METER SETTER WITH
DOUBLE CHECK VALVE
(BACKFLOW PREVENTER)
METER BOX LID, CAST IRON
1' FROM EDGE OF ROW
SERVICE LINE
FROM STREET
1. METER AND PRIVATE SERVICE LINE NOT IN CONTRACT UNLESS SPECIFIED
2. INCLUDE STONE IN PRICE OF METER BOX.
3. METER SETTER SIZE AS NOTED ON PLANS.
4. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE.
3/4" X 18"
BRASS NIPPLE
3/4 Inch Gate Valve
Required on
Customer side
Within 12 inches of
the Meter BoxRWPROPERTY
METER TO BE INSTALLED
BRICK SUPPORT
9"
W
14
VALVE BOX
24"x18" RECTANGULAR
17"
18"
24"
3 1/2"
18"
12"
A BA
ELEVATION
ISOMETRIC
PLAN
NO SCALE
TYPICAL METER BOX DETAIL FOR 3/4" SERVICE
CAST IRON
16 3/4"
11"SIGMAWATER
METER
W
15 HARNETT COUNTY SPECIFICATIONSNOTED
2 WATER DISTRIBUTION SYSTEMHARNETT COUNTY - NORTH CAROLINA2009
3
HCDPU
ABS PLASTIC
W.W.R.S:\Mapping\MAIN SEWER & WATER DETAILS 2009\Details\HC Logos.jpgADJUSTABLE
VALVE BOX
BRICK TO
SUPPORT
VALVE BOX
MECHANICAL JOINT
WITH GRIP RING
36" THREADED BRASS
PIPE NIPPLE 2" DIA CONCRETE BLOCKING
MIN. 1/3 C.Y. AT 3000 P.S.I.
PRECAST CONCRETE
PROTECTION RING
SQUARE HEAD
VALVE NUT ONLY
MIN 1/5" OF PROTECTION
RING TO BE EXPOSED
TAMPED BACKFILL
THREADED
COUPLING
WATER MAIN
2"
1"
BACKFILL TO EDGE
FINISHED GRADE
MIN 6"
MIN OF 24" THREADED
BRASS PIPE NIPPLE 2" DIA
OR LONGER TO BRING PIPE
UP TO FINISHED GRADE2" BRASS
THREADED
PIPE NIPPLE
MIN 18"
END CAP ON PLUG
WITH 2" THREADED PORT
NOTE: SEE TYPICAL VALVE BOX DETAIL
FOR BRICK INSTALLATION
C6.3
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C6.3 SANITARY SEWER DETAILS.DWGPLOTTED: 8/1/2022 10:24 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
SANITARY SEWER DETAILS
COVER
FRAME & COVER
FRAME
NOTE:
CONCRETE ENCASEMENT SHALL ONLY BE USED IN
AREAS WHERE COVER IS TO BE FLUSH WITH PAVEMENT
OR CONCRETE. CONCRETE ENCASEMENT SHALL NOT BE
USED IN NON-TRAFFIC AREAS AND ABOVE GRADE
INSTALLATIONS.
USE MIN. 4 EA. 3/8" ANCHOR
BOLTS TO SECURE FRAME TO MANHOLE
23.5"
RAM-NEK
SEALANT
2"1"
BASE COURSEBASE COURSE
FINISHED GRADE
1.5" MIN.
6" MIN.
COMPACTED FILLCOMPACTED FILL
STD. MANHOLE
RING & COVER
SANITARY SEWER
(0'-8' DEPTH)
PIPE LAYING CONDITION "A"
PIPE
O.D.
HAND PLACED
DENSELY COMPACTED
BACKFILL TO 1 FT.
ABOVE TOP OF PIPE
BEDDED PIPE
MINIMUM STONE
EMBEDMENT AS
INDICATED. GREATER IF
REQUIRED BY
MANUFACTURER
12 PIPE
O.D.
24" + O.D. MAX.
12" + O.D. MIN.
D/8≥3"D/4
D/2
D/8≥3"
24" + O.D. MAX.
12" + O.D. MIN.
12 PIPE
O.D.
MINIMUM STONE
EMBEDMENT AS
INDICATED. GREATER IF
REQUIRED BY
MANUFACTURER
BEDDED PIPE
HAND PLACED
DENSELY COMPACTED
BACKFILL TO 1 FT.
ABOVE TOP OF PIPE
PIPE
O.D.
SANITARY SEWER
(<8'-16' DEPTH)
PIPE LAYING CONDITION "B"
SHAPED STONE
TO PROVIDE BEARING
ALONG ENTIRE LENGTH
OF PIPE BARREL
SHAPED STONE
TO PROVIDE BEARING
ALONG ENTIRE LENGTH
OF PIPE BARREL
STYPICAL PIPE LAYING CONDITION DETAIL
16
SFRAME & COVER DETAIL
21
TYPICAL STANDARD MANHOLE
TYPICAL SEWER SERVICE CONNECTION DETAIL S
USE 4 EA. 38" ANCHOR BOLTS
TO BOLT FRAME TO SPACER.
USE ROPE MASTIC SEAL
BETWEEN FRAME AND SPACER.
STANDARD MANHOLE
RING AND COVER
MANHOLE STEPS
16" O.C.
BRICK & MORTAR INVERT
MIN. 6" GRAVEL BEDDING
ECCENTRIC
TAPER UNIT
RISER UNIT
BASE UNIT
4' DIA. MIN.5"
2'-0", 3'-0"
OR 4'-0"
8" MAX. FOR SPACER
8"
JOINTS SHALL BE SEALED
WITH A RUBBER O-RING
GASKET OR ROPE MASTIC SEAL.
CEMENT GROUT ALL JOINTS
INSIDE AND OUT
112":12" SLOPE
ON ALL INVERTS
EXTENDED BASE
(REQUIRED OVER 12')
STYPICAL STANDARD PRECAST CONCRETE MANHOLE DETAIL
4" PVC VERTICAL
4" SWEEP WYE
SERVICE LINE
SANITARY SEWER
MAIN
TEE BRANCH
SLOPE MIN. 1%
PLUG
STOP AT R/W
45°SANITARY TEE
(SAME MATERIAL
AS MAIN)
CLEANOUT PLUG AND CAP
NOTE:
EASEMENT SHALL BE PROVIDED FOR SERVICE CONNECTION WHERE
SERVICE CONNECTION IS PLACED OUTSIDE OF R/W DUE TO PHYSICAL
CONSTRAINTS.CAST IRON VALVE BOX
W/ CHARLOTTE HUB
3'-5'
1' inside
RW
NOTE:
IN NON-TRAFFIC AREAS,TOP OF FRAME AND COVER SHALL BE
INSTALLED AT LEAST 2 FT ABOVE FINISH GRADE OR
AT LEAST 1 FT ABOVE FLOOD STAGE.
24
29
SEE DETAIL S-25
NOTES:
IN-LINE WYE
FITTING FOR NEW
CONSTRUCTION OR
ROMAC-CB SADDLE
FOR TAP ON EXISTING
SANITARY SEWER MAIN.
BRASS
12" MIN.
(DO NOT GLUE)
SCH 40 PVC VERTICAL
SCH 40 PVC
SCH 40 PVC
WIDTH AS
REQUIRED
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
O
H
E
OHEOHEOHE
OHE
OHE
OHE
OHE
OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
EIS
MAG NAIL CP
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP PP PP PP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPFOM
GW
FOM FOM
749.89 LF @ 0.22%721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
MH
TOP-217.73
INV-207.19
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT
WOODALL JR & LANDA
KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
1
11
10
12
13
9
20 1516171819
2 3 4 5 867
14
CBU
L1
C1 L2
21
22 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSMH#2SS
DOG HOUSE
SSMH#1SSSSSSSSSSSSOHEOHEOHEOHEOHEOHE OHEWWWWWW
W W W W W W W W W
W W10+0011+0012+0013+0014+0014+77SAWYER MILL DRIVE
L1.0
E N G I NE ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGIN
E
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\L1.0 LANDSCAPE PLAN.DWGPLOTTED: 8/1/2022 10:24 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
LANDSCAPE PLAN
SCALE IN FEET
60'120'30'60'
SCALE: 1 IN = 60 FT
SCALE IN FEET
HORIZONTAL
0 N1" = 60'
1.STREET TREES SHALL BE INSTALLED SUCH THAT ONE TREE IS REQUIRED PER 50' ALONG
A RESIDENTIAL STREET.
2.DO NOT PLACE STREET TREES WITHIN A PUBLIC STORM OR UTILITY EASEMENT.
3.ALL TREES SHALL BE MIN. 6' TALL AND 2" CALIPER AT TIME OF PLANTING.
4.LANDSCAPE BUFFER SHALL COMPLY WITH THE REQUIREMENTS SET FORTH IN THE
PRELIMINARY SUBDIVISION APPROVAL. SEE DETAIL THIS SHEET FOR REQUIREMENTS.
5.LANDSCAPING IN AREAS OUTSIDE OF RIGHT OF WAY ARE TO BE PROVIDED BY THE
DEVELOPER. ANY LANDSCAPING INSTALLED WITHIN THESE AREAS ARE TO BE
MAINTAINED BY THE DEVELOPER UNTIL HOME OWNERS ASSOCIATION (HOA) IS
ESTABLISHED. HOA WILL BE RESPONSIBLE FOR CONTINUED MAINTENANCE OF
LANDSCAPING AND ANY IMPROVEMENTS OUTSIDE THE RIGHT OF WAY.
6.ADDITIONAL LANDSCAPING ON SITE MAY BE PROVIDED BY DEVELOPER.
SITE LANDSCAPE NOTES:
KEY
WO
QTY
55
BOTANICAL NAME COMMON NAME CONTAINER SIZE HEIGHT
B&B 2" CAL 6
PLANTING SCHEDULE:
WM 440 B&B 2" CAL 6
QUERCUS PHELLOS WILLOW OAK
MYRICA CERIFERA WAX MYRTLE
BUFFER PLANTING (1650 LF TOTAL)
(NOT TO SCALE)
WAX MYRTLE (MYRICA CERIFERA)
24" HIGH @ PLANTING
WILLOW OAK (QUERCUS PHELLOS)
2" CALIPER, 6' HIGH @ PLANTING
30' STREETSCAPE BUFFER PLANTING (1650 LF TOTAL)
30'
30' MAX
5' MAX SPACING
25'ROW DEDICATION
30' STREETSCAPE BUFFER (1310 LF)
30' STREET YARD (200 LF)
30' PUBLIC UTILITY EASEMENT
30' STREET YARD
(140 LF)
STREET
LIGHTING
LEGEND:
LANDSCAPE
BERM
TP
CONSTRUCTION ENTRANCE/EXIT
SILT FENCE OUTLET
TEMP. SEED/MULCH/PERM. SEED
SILT FENCE
TREE PROTECTION FENCE
OUTLET PROTECTION
TS M
PS
DIVERSION DITCH
ROCK CHECK DAM
INLET PROTECTION
SILT SACK
STOCKPILE
DISTURBANCE LIMITS
COIR WATTLE
CONCRETE WASH AREA
HORSESHOE INLET PROTECTION
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHE
OHE
OHE
OHE
OHE
OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
EIS
MAG NAIL CP
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP PP PP PP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPFOM
GW
FOM FOM217216215218219220221 220
221
222
219220221222220219
220221
220
217
749.89 LF @ 0.22%721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
MH
TOP-217.73
INV-207.19
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT
WOODALL JR & LANDA
KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
219
220
22
1
EC1.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\EC1.0 EROSION CONTROL PLAN - INITIAL PHASE.DWGPLOTTED: 8/1/2022 10:25 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
EROSION CONTROL PLAN - INITIAL PHASE
SCALE IN FEET
60'120'30'60'
SCALE: 1 IN = 60 FT
SCALE IN FEET
HORIZONTAL
0
LEGEND:N1" = 60'
7 daysPerimeter dikes, swales, ditches and slopes
SITE AREA DESCRIPTION STABILIZATION
NPDES STABILIZATION TABLE
TIMEFRAME EXCEPTIONS
7 days
14 days
NoneHigh Quality Water (HQW) Zones
Slopes steeper than 3:1 If slopes are 10' or less in length and are not
steeper than 2:1, 14 days are allowed.
Slopes 3:1 or flatter 7 days for slopes greater than 50' in length
7 days
All other areas with slopes fatter than 4:1 14 days None, except for perimeters and HQW Zones
None
CONSTRUCTION
ENTRANCE
SILT FENCE, TYP.
PROPERTY BOUNDARY
PROPERTY BOUNDARY
SILT FENCE OUTLET
SILT FENCE
INSTALL 24" RCP TEMP.
DRIVEWAY PIPE
DISTURBANCE LIMITS
SILT FENCE
OUTLET
SILT FENCE OUTLET
1.THE TEMPORARY DIVERSION DITCHES, SILT FENCE, AND LIMITS OF
DISTURBANCE SHOWN ON THIS PLAN ARE GRAPHICAL
REPRESENTATION OF THE ACTUAL EROSION CONTROL MEASURES
THAT SHALL BE INSTALLED UNDER THIS PROJECT. DUE TO SCALE OF
THIS DRAWING, THESE MEASURES ARE GRAPHICALLY DEPICTED AND
MAY BE BEYOND WHERE THEY ACTUALLY WILL BE INSTALLED IN THE
FILED. HOWEVER, UNDER NO CIRCUMSTANCES IS THERE TO BE
DISTURBANCE WITHIN THE WETLAND AND/OR STREAM BUFFER AREAS.
2.TOTAL DISTURBED AREA = 11.78 AC
3.REFER TO DETAIL SHEET EC3.0 FOR CONSTRUCTION SEQUENCE,
EROSION CONTROL NARRATIVE, MAINTENANCE NOTES, STABILIZATION
INSTRUCTIONS & EROSION CONTROL DETAILS.
4.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT
NCDENR STANDARDS AND REGULATIONS.
5.SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED.
6.THERE SHALL BE NO DISTURBANCE OUTSIDE THE LIMITS SHOWN ON
THIS PLAN WITHOUT AN APPROVED PLAN AMENDMENT BY NCDENR.
7.ALL DISTURBED AREAS SHALL BE SEEDED PER STABILIZATION TABLE.
8.CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SELF-INSPECTION
LOG.
9.ALL DIVERSION DITCHES SHALL HAVE 12" COIR WATTLE CHECK DAMS
SPACED EVERY 100 L.F. OF DITCH.
10.CONTRACTOR SHALL CLEAN OUT ALL DOWNSTREAM STORM DRAINAGE
SYSTEM AFTER PHASE CONSTRUCTION IS STABILIZED.
NOTES:
PROPERTY BOUNDARY
SILT FENCE OUTLET, TYP.
ROW DEDICATION
PROPERTY BOUNDARY
ADDITIONAL LIMITS
SHOWN FOR
OPTIONAL BERM
CONSTRUCTION.
STOCKPILE
W/ SILT
FENCE
CONCRETE
WASHOUT
AREA
INLET PROTECTION
TP
CONSTRUCTION ENTRANCE/EXIT
SILT FENCE OUTLET
TEMP. SEED/MULCH/PERM. SEED
SILT FENCE
TREE PROTECTION FENCE
OUTLET PROTECTION
TS M
PS
DIVERSION DITCH
ROCK CHECK DAM
INLET PROTECTION
SILT SACK
STOCKPILE
DISTURBANCE LIMITS
COIR WATTLE
CONCRETE WASH AREA
HORSESHOE INLET PROTECTION
TDD
221222222221219218
217
216
219 218218219
221
221
221
218217219
216
219218217216216
OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
OH
E
OHEOHEOHE
OHE
OHE
OHE
OHE
OHE OHE OHE
SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x SS x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx GxPROSPECT CHURCH ROADNC 55 E(60' PUBLIC R/W)(60' PUBLIC R/W)
MAG NAIL
MAG NAIL
EIS
EIS
MAG NAIL CP
CP
24"
R
C
P
18" RCP15" RCPGRAVEL/SOIL DRIVEW/M W/MC/O
SHELTER
PP
PP
PPPP PP PP PP PP PP PP
PP
W/V W/V
W/VW/V
FH FOM FOM
RCPFOM
GW
FOM FOM217216215218219220221 220
221
222
219220221222220219
220221
220
217
749.89 LF @ 0.22%721.83 LF @ 0.19%
LINWOOD M. COUNCIL
DIANNE A. COUNCIL
D.B.3579, PG.671
ZONING: RA-30
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.9, PG.64
D.B.1129, PG.443
ZONING: COMM
USE: AGRICULTURAL
N.C. GRID MONUMENT "JOSEY"
N.C. GRID COORDINATES, NAD
83 ELEV - 218.91'
N - 588,002.21
E - 2,100,393.42
CF - 0.99986934
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
MH
TOP-217.29
INV-204.17
MH
TOP-219.39
INV-205.83
MH
TOP-217.73
INV-207.19
APPROXIMATE LOCATION OF GAS LINEAPPROXIMATE LOCATION OF WATER LINE
BLOCK
HOUSE
DAVIS BRYANT
WOODALL JR & LANDA
KAY WOODALL CAPPS
D.B.3269, PG.0007
ZONING: RA-20M
USE: RESIDENTIAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0479
ZONING: RA-30/COMM
USE: AGRICULTURAL
EDWARD S. TURLINGTON
M.B.2002, PG.855
D.B.1641, PG.0467
ZONING: RA-30/COMM
USE: RESIDENTIAL
BHR PROPERTIES
M.B.2002, PG.855
D.B.3117, PG.0690
ZONING: RA-30/COMM
USE: RESIDENTIAL
INV: 211.08
INV: 211.59
INV: 212.08
INV: 212.00
INV: 214.07
INV: 213.80
219
220
22
1
TDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDD
TDD
TDD
TDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDDTDD
TDD
TDD
TDD
TDD TDD TDD TDD TDD TDDTDD TDD
TDDTDD TDD TDD TDD TDD TDD
TDD
1
11
10
12
13
9
20 1516171819
2 3 4 5 867
14
CBU
PC:
1
1
+
0
2
.
6
PT:12+25.9
L1
C1 L2
21
22 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSMH#2SS
DOG HOUSE
SSMH#1SSSSSSSSSSSSOHEOHEOHEOHEOHEOHE OHEWWWWWW
W W W W W W W W W
W WEC2.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\EC2.0 EROSION CONTROL PLAN - CONSTRUCTION PHASE.DWGPLOTTED: 8/1/2022 10:25 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
EROSION CONTROL PLAN - CONSTRUCTION PHASE
SCALE IN FEET
60'120'30'60'
SCALE: 1 IN = 60 FT
SCALE IN FEET
HORIZONTAL
0
LEGEND:N1" = 60'
1.THE TEMPORARY DIVERSION DITCHES, SILT FENCE, AND LIMITS OF
DISTURBANCE SHOWN ON THIS PLAN ARE GRAPHICAL
REPRESENTATION OF THE ACTUAL EROSION CONTROL MEASURES
THAT SHALL BE INSTALLED UNDER THIS PROJECT. DUE TO SCALE OF
THIS DRAWING, THESE MEASURES ARE GRAPHICALLY DEPICTED AND
MAY BE BEYOND WHERE THEY ACTUALLY WILL BE INSTALLED IN THE
FILED. HOWEVER, UNDER NO CIRCUMSTANCES IS THERE TO BE
DISTURBANCE WITHIN THE WETLAND AND/OR STREAM BUFFER AREAS.
2.TOTAL DISTURBED AREA = 11.78 AC
3.REFER TO DETAIL SHEET EC3.0 FOR CONSTRUCTION SEQUENCE,
EROSION CONTROL NARRATIVE, MAINTENANCE NOTES, STABILIZATION
INSTRUCTIONS & EROSION CONTROL DETAILS.
4.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT
NCDENR STANDARDS AND REGULATIONS.
5.SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED.
6.THERE SHALL BE NO DISTURBANCE OUTSIDE THE LIMITS SHOWN ON
THIS PLAN WITHOUT AN APPROVED PLAN AMENDMENT BY NCDENR.
7.ALL DISTURBED AREAS SHALL BE SEEDED PER STABILIZATION TABLE.
8.CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SELF-INSPECTION
LOG.
9.ALL DIVERSION DITCHES SHALL HAVE 12" COIR WATTLE CHECK DAMS
SPACED EVERY 100 L.F. OF DITCH.
10.CONTRACTOR SHALL CLEAN OUT ALL DOWNSTREAM STORM DRAINAGE
SYSTEM AFTER PHASE CONSTRUCTION IS STABILIZED.
NOTES:
7 daysPerimeter dikes, swales, ditches and slopes
SITE AREA DESCRIPTION STABILIZATION
NPDES STABILIZATION TABLE
TIMEFRAME EXCEPTIONS
7 days
14 days
NoneHigh Quality Water (HQW) Zones
Slopes steeper than 3:1 If slopes are 10' or less in length and are not
steeper than 2:1, 14 days are allowed.
Slopes 3:1 or flatter 7 days for slopes greater than 50' in length
7 days
All other areas with slopes fatter than 4:1 14 days None, except for perimeters and HQW Zones
None
CONSTRUCTION
ENTRANCE
SILT FENCE, TYP.
COIR WATTLE, TYP.
CONCRETE
WASHOUT
AREA
PROPERTY BOUNDARY
TDD-C
PROPERTY BOUNDARY
SILT FENCE OUTLET
STOCKPILE
W/ SILT
FENCE
SILT FENCE OUTLET
ROCK CHECK DAM
TEMPORARY
DIVERSION DITCH
COIR WATTLE, TYP.
PROPOSED
CONTOUR
INSTALL 24" HDPE TEMP.
DRIVEWAY PIPE
ROCK CHECK DAM
DISTURBANCE LIMITS
TDD-A
TDD-B
TDD-D
SILT FENCE
OUTLET
SILT FENCE OUTLET
PROPERTY BOUNDARY
TEMPORARY DIVERSION DITCH SCHEDULE
DITCH
DESIGNATION
DRAINAGE
AREA (AC)
RUNOFF
COEFFICIENT Q10 (CFS)
AVG.
SLOPE
(%)
FLOW
DEPTH (FT)
VELOCITY
(FPS)SHAPE GEOMETRY (FT)LINING MATERIAL
A 2.54 0.30 7.86 1.2%0.64 2.87 TRAPEZOIDAL b=2', d=18", m=2:1 SYNTHETIC MAT
B 3.64 0.30 7.86 1.9%0.53 5.23 TRAPEZOIDAL b=2', d=18", m=2:1 SYNTHETIC MAT
C 0.56 0.30 7.86 1.5%1.32 2.74 TRAPEZOIDAL b=2', d=18", m=2:1 SYNTHETIC MAT
D 2.17 0.30 7.86 2.2%0.39 4.78 TRAPEZOIDAL b=2', d=18", m=2:1 SYNTHETIC MAT
TS M
PS
TS M
PS
TS M
PS
SILT FENCE, TYP.
ROCK CHECK DAM
HORSESHOE INLET
PROTECTION
ROW DEDICATION
PROPERTY BOUNDARY
RECEIVING PIT,
TYP.
BORE PIT
EXCAVATION, TYP.
ADDITIONAL LIMITS
SHOWN FOR
OPTIONAL BERM
CONSTRUCTION.
EXISTING
CONTOUR
SILT FENCE
MATTING MUST BE INSTALLED IMMEDIATELY UPON
CONSTRUCTION OF TEMPORARY DIVERSION DITCHES
MATTING MUST BE INSTALLED IMMEDIATELY UPON
CONSTRUCTION OF TEMPORARY DIVERSION DITCHES
EC3.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\EC3.0 EROSION CONTROL DETAILS I.DWGPLOTTED: 8/1/2022 10:25 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
EROSION CONTROL DETAILS I
1" = 60'
MAINTENANCE/INSPECTION PROCEDURES
THE FOLLOWING ARE INSPECTION AND MAINTENANCE PRACTICES THAT WILL BE USED TO MAINTAIN EROSION AND SEDIMENT CONTROLS.
·ALL CONTROL MEASURES WILL BE INSPECTED BY THE SUPERINTENDENT, THE PERSON RESPONSIBLE FOR THE DAY TO DAY SITE OPERATION OR SOMEONE APPOINTED BY THE SUPERINTENDENT,
DAILY AND WITHIN 24 HOURS OF EVERY RAINFALL EVENT.
·SILT FENCE & FABRIC INLET PROTECTION: INSPECT FOR DEPTH OF SEDIMENT, TEARS, TO SEE IF THE FABRIC IS SECURELY ATTACHED TO THE FENCE POSTS, AND TO SEE THAT THE FENCE POSTS ARE
FIRMLY IN THE GROUND. BUILT UP SEDIMENT WILL BE REMOVED FROM SILT FENCE WHEN IT HAS REACHED ONE-THIRD THE HEIGHT OF THE FENCE.
·SILT FENCE OUTLET: INSPECT THE SILT FENCE OUTLETS PER THE SCHEDULE OUTLINED ABOVE. CHECK FOR TEARS IN THE FABRIC AND ADDRESS REPAIRS PER THE "SILT FENCE & FABRIC INLET
PROTECTION" NOTES ABOVE. REMOVE ACCUMULATED SEDIMENT PER THIS REQUIREMENT AS WELL. INSPECT THE STONE PORTION OF THIS MEASURE AND REPLACE ANY DISPLACED STONE. NOTE ANY
LEANING STAKES AND RE-INSTALL THEM VERTICAL AND SECURELY.
·HORSESHOE INLET PROTECTION: INSPECT ROCK PIPE INLET PROTECTION PER THE SCHEDULE ABOVE. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS
WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE
CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE. ANY RIP RAP DISPLACED FROM THE STONE HORSESHOW MUST BE REPLACED IMMEDIATELY.
·ROCK CHECK DAMS: INSPECT DAMS PER THE SCHEDULE ABOVE. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE CHANNEL WHEN NEEDED. ANTICIPATE
SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS
BETWEEN DAMS, ADDITIONAL MEASURES CAN BE TAKEN SUCH AS INSTALLING A PROTECTIVE RIP-RAP LINE IN THAT PORTION OF THE CHANNEL. REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS
AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM, AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE
DAM. ADD STONE TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION.
·DIVERSION DIKES/SWALES: INSPECT AND ANY BREACHES PROMPTLY REPAIRED. SEDIMENT SHALL BE REMOVED FROM THE FLOW AREA IMMEDIATELY AFTER EACH RAINFALL
·TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE
PERIODIC TOP-DRESSING WITH 2-3" STONE. AFTER A RAINFALL, IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO ROADWAYS.
·SEDIMENT BASIN: INSPECT AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS
ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PLACE REMOVED SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND
OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE
RISER AND POOL AREA. REPAIR BAFFLES AND SKIMMERS AS NEEDED.
·INLET PROTECTION: INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (½ INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS
TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED.
·SEEDING, FERTILIZING, AND MULCHING: INSPECT SEEDED AREAS FOR FAILURE AND NECESSARY REPAIRS AND RE-SEEDING SHALL BE MADE WITHIN THE SAME SEASON. TEMPORARY AND PERMANENT
SEEDING AND PLANTING WILL BE INSPECTED FOR BARE SPOTS, WASHOUTS, AND HEALTHY GROWTH.
·MAINTAIN THE ON-SITE RAIN GAUGE & DATA AND STORMWATER INSPECTION LOG SHEETS. THIS PERMIT INFORMATION MUST BE COLLECTED AND MAINTAINED UNTIL HARNETT COUNTY HAS CLOSED THE
PROJECT & SURETY HAS BEEN RELEASED.
·THE CONTACT PERSON IS REQUIRED TO MAINTAIN A LOG OF SELF-INSPECTIONS PER REQUIREMENTS AS OUTLINED IN
NCG01000 PERMIT. THE REPORTS WILL BE KEPT ON SITE DURING CONSTRUCTION AND AVAILABLE UPON REQUEST TO THE
OWNER, ENGINEER OR ANY FEDERAL, STATE OR LOCAL AGENCY APPROVING SEDIMENT AND EROSION PLANS, OR
STORMWATER MANAGEMENT PLANS. THIS PERMIT INFORMATION MUST BE COLLECTED AND MAINTAINED UNTIL HARNETT COUNTY HAS CLOSED THE PROJECT.
·THE SITE SUPERINTENDENT WILL SELECT UP TO THREE INDIVIDUALS WHO WILL BE RESPONSIBLE FOR INSPECTIONS, MAINTENANCE AND REPAIR ACTIVITIES, AND FILLING OUT THE INSPECTION AND
MAINTENANCE REPORT.
·PERSONNEL SELECTED FOR INSPECTION AND MAINTENANCE RESPONSIBILITIES WILL RECEIVE TRAINING FROM THE SITE. SUPERINTENDENT: THEY WILL BE TRAINED IN ALL THE INSPECTION AND
MAINTENANCE PRACTICES NECESSARY FOR KEEPING THE EROSION AND SEDIMENT CONTROLS USED ONSITE IN GOOD WORKING ORDER.
·GROUND STABILIZATION: SOIL STABILIZATION SHALL BE ACHIEVED ON ANY AREA OF A SITE WHERE LAND-DISTURBING ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED ACCORDING TO THE
FOLLOWING SCHEDULE:
A.ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3 HORIZONTAL TO 1
VERTICAL (3:1) SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS
PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY.
B.ALL OTHER DISTURBED AREAS SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER
AS SOON AS POSSIBLE BUT IN ANY EVENT WITHIN 14 CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY
DUST CONTROL
VEGETATIVE COVER
FOR DISTURBED AREAS NOT SUBJECT TO TRAFFIC, VEGETATION
PROVIDES THE MOST PRACTICAL METHOD OF DUST CONTROL.
MULCH
WHEN PROPERLY APPLIED, MULCH OFFERS A FAST, EFFECTIVE MEANS
OF CONTROLLING DUST.
MAINTENANCE
MAINTAIN DUST CONTROL MEASURES THROUGH DRY WEATHER
PERIODS UNTIL ALL DISTURBED AREAS HAVE BEEN STABILIZED.
1.THE CONTRACTOR SHALL AT A MINIMUM IMPLEMENT THE CONTRACTOR'S REQUIREMENTS OUTLINED BELOW AND THOSE MEASURES SHOWN ON THE EROSION AND
SEDIMENT CONTROL PLAN. IN ADDITION THE CONTRACTOR SHALL UNDERTAKE ADDITIONAL MEASURES REQUIRED TO BE IN COMPLIANCE WITH APPLICABLE PERMIT
CONDITIONS AND STATE WATER QUALITY STANDARDS.
2.TOTAL DISTURBANCE LIMITS = 11.78 ACRES.
3.ANY GRADING BEYOND THE DENUDED LIMITS SHOWN IN THE PLAN IS A VIOLATION OF THE NORTH CAROLINA SEDIMENTATION CONTROL LAW & IS SUBJECT TO A FINE.
4.GRADING MORE THAN 1 ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE THE NORTH CAROLINA SEDIMENTATION CONTROL LAW AND IS
SUBJECT TO A FINE.
5.ALL EROSION CONTROL PRACTICES SHALL BE IN ACCORDANCE WITH ALL NCDENR STANDARDS AND SPECIFICATIONS.
8.CONSTRUCTION ENTRANCES SHALL BE MAINTAINED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. A MINIMUM OF ONE CONSTRUCTION ENTRANCE SHALL BE
INSTALLED AND UTILIZED. THIS ENTRANCE SHALL BE BETWEEN THE LIMITS OF DISTURBANCE AND ANY ROAD RIGHT OF WAY.
9.ADJACENT PROPERTIES AND RIGHT-OF-WAY SHALL BE KEPT FREE OF MUD AND/OR SEDIMENT-LADEN RUNOFF.
10.THE EROSION CONTROL MEASURES SHOWN ON THIS PLAN ARE RECOMMENDED AS A MINIMUM IN ORDER TO CONTROL RUN-OFF. IT IS POSSIBLE THAT MORE STRINGENT
MEASURES MAY BE NEEDED AS DETERMINED BY THE CONTRACTOR, PROJECT ENGINEER, AND/OR EROSION CONTROL INSPECTOR. IF IT IS DETERMINED THAT
ADDITIONAL RUN-OFF CONTROL IS NEEDED, SUCH MEASURES SHALL BE INSTALLED IMMEDIATELY.
11.SHOULD MAINTENANCE ISSUES ARISE, PLEASE CONTACT HAL LONG AT (919) 810-6151.
12.CONTRACTOR SHALL LOCATE AND VERIFY LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO BEGINNING WORK.
EROSION CONTROL NOTES
STRUCTURAL PRACTICES
1.SILT FENCE (SEDIMENT FENCE): SILT FENCE CAN BE USED BELOW DISTURBED AREAS SUBJECT TO SHEET AND RILL EROSION. SILT FENCES SHALL BE PROVIDED WHERE
SHOWN AND AS NEEDED ON THE SITE PLAN. THESE BARRIERS SHALL BE USED TO CONTAIN SEDIMENT.
2.SILT FENCE OUTLET: GRAVEL SILT FENCE OUTLETS SHALL BE PROVIDED WHERE SHOWN AND AS NEEDED ON THE SITE PLAN. THESE OUTLETS SHALL BE LOCATED AT ALL
LOW POINTS IN A RUN OF SILT FENCE AND USED TO DISCHARGE "CLEAN WATER" OFF-SITE.
3.DIVERSION DITCHES: USE DIVERSION DITCHES TO CONVEY SEDIMENT LADEN RUNOFF TO EROSION CONTROL BMPS AS SHOWN ON THE PLANS.
4.CONSTRUCTION ENTRANCE: CONSTRUCTION TRAFFIC SHALL BE LIMITED TO STABILIZED AREAS. AT A MINIMUM, A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL
BE PROVIDED AS SHOWN ON THIS DRAWING. VEHICLE WHEELS SHALL BE CLEAN WHEN LEAVING THE SITE TO PREVENT THE TRACKING OF MUD ON PAVED ROADS.
5.ROCK CHECK DAMS: ROCK CHECK DAMS CAN BE USED TO REDUCE EROSION IN A DRAINAGE CHANNEL TO LIMIT EROSION BY REDUCING VELOCITY IN OPEN CHANNELS.
6.SEDIMENT BASINS: SEDIMENT BASINS WITH SKIMMERS AND POROUS BAFFLES ARE USED TO RETAIN SEDIMENT ON THE CONSTRUCTION SITE, AND PREVENT
SEDIMENTATION IN OFF-SITE STREAMS, LAKES, AND DRAINAGE WAYS
7.INLET PROTECTION: HARDWIRE CLOTH AND GRAVEL INLET PROTECTION DEVICES CAN BE USED PREVENT SEDIMENT FROM ENTERING YARD INLETS, GRATED STORM
DRAINS OR DROP INLETS DURING CONSTRUCTION. THIS PRACTICE ALLOWS EARLY USE OF THE STORM DRAIN SYSTEM
SEDIMENT & EROSION CONTROLS
IT IS THE CONTRACTORS RESPONSIBILITY TO IMPLEMENT THE EROSION AND SEDIMENT CONTROLS AS SHOWN ON THE EROSION AND SEDIMENT CONTROL PLAN. IT IS ALSO THE
CONTRACTOR'S RESPONSIBILITY TO ENSURE THESE CONTROLS ARE PROPERLY INSTALLED, MAINTAINED AND FUNCTIONING PROPERLY TO PREVENT POLLUTED WATER FROM
LEAVING THE PROJECT SITE. THE CONTRACTOR WILL ADJUST THE EROSION CONTROLS SHOWN ON THE EROSION AND SEDIMENT CONTROL PLAN AND ADD ADDITIONAL CONTROL
MEASURES, AS REQUIRED, TO ENSURE THE SITE MEETS ALL FEDERAL, STATE AND LOCAL EROSION AND SEDIMENT CONTROL REQUIREMENTS. ALL VEGETATIVE AND STRUCTURAL
EROSION AND SEDIMENT CONTROL PRACTICES BE TO THE STANDARDS OF THE NC DEPT. OF ENVIRONMENTAL MANAGEMENT - LAND QUALITY SECTION, AND ARTICLE 10 OF THE
HARNETT COUNTY UNIFIED DEVELOPMENT CODE, LATEST EDITION.
VEGETATIVE PRACTICES
1.TEMPORARY SEEDING: DISTURBED AREAS THAT ARE NOT ANTICIPATED TO BE BROUGHT TO FINAL GRADE FOR A PERIOD OF MORE THAN 7 OR 14 CALENDAR DAYS MUST
RECEIVE TEMPORARY SEEDING (SEE NPDES TABLE). A QUICK GROWING GRASS SPECIES, WHICH WILL PROVIDE AN EARLY COVER DURING THE SEASON IN WHICH IT IS
PLANTED AND WILL NOT LATER COMPETE WITH THE PERMANENT GRASSING, SHOULD BE USED. TEMPORARY SEEDING SHALL BE PER HARNETT COUNTY REQUIREMENTS.
2.TEMPORARY GRASSING: THE SEEDED OR SEEDED AND MULCHED AREA(S) SHALL BE ROLLED AND WATERED OR HYDROMULCHED OR OTHER SUITABLE METHODS IF
REQUIRED TO ASSURE OPTIMUM GROWING CONDITIONS FOR THE ESTABLISHMENT OF A GOOD GRASS COVER.
3.TEMPORARY REGRASSING: IF, AFTER 14 DAYS FROM SEEDING, THE TEMPORARY GRASSED AREAS HAVE NOT ATTAINED A MINIMUM OF 75 PERCENT GOOD GRASS COVER,
THE AREA WILL BE REWORKED AND ADDITIONAL SEED APPLIED SUFFICIENT TO ESTABLISH THE DESIRED VEGETATIVE COVER. RESEED AND MULCH BARE SPOTS LARGER
THAN 9 SQUARE FEET.
4.PERMANENT SEEDING: ALL AREAS WHICH HAVE BEEN DISTURBED BY CONSTRUCTION WILL, AS A MINIMUM, BE SEEDED. PERMANENT SEEDING SHALL BE PER HARNETT
COUNTY REQUIREMENTS. IF GROWTH IS NOT ESTABLISHED BY FINAL PROJECT INSPECTION, CONTINUE SPECIFIED ATTENTION UNTIL THE STAND OF GRASS IS ACCEPTABLE.
NOTE THAT PERMANENT GROUNDCOVER MUST BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORE THAN 90 CALENDAR DAYS, WHICHEVER IS
SHORTER.
MANAGEMENT STRATEGIES
1.STOCKPILING MATERIAL: NO EXCAVATED MATERIAL SHALL BE STOCKPILED IN SUCH A MANNER AS TO DIRECT RUNOFF DIRECTLY OFF THE PROJECT SITE INTO ANY
ADJACENT WATER BODY OR STORM WATER COLLECTION FACILITY. PER NCDWQ CONSTRUCTION GENERAL PERMIT REVISED AUGUST 4, 2011 ALL EARTHEN MATERIAL
STOCKPILES MUST BE LOCATED 50' FROM STORM DRAINS AND STREAMS UNLESS NO OTHER REASONABLE ALTERNATIVE IS AVAILABLE.
2.RIP-RAP OUTLET PROTECTION: ALL RIP-RAP SHALL BE INSTALLED WITH FILTER FABRIC BENEATH.
3.SOIL DISPOSAL: DISPOSE OF ALL STOCKPILED MATERIAL TO AN APPROVED PERMITTED HARNETT COUNTY DISPOSAL SITE.
4.DEWATERING: ALL TRENCH/PIT DEWATERING MUST DISCHARGE TO AN APPROVED S&EC MEASURE OR SILT SACK PRIOR TO LEAVING THE SITE.
5.PERMANENT EROSION CONTROL: THE EROSION CONTROL FACILITIES OF THE PROJECT SHOULD BE DESIGNED TO MINIMIZE THE IMPACT ON THE OFFSITE FACILITIES.
EROSION & SEDIMENT CONTROL NARRATIVE
PROJECT DESCRIPTION
THE PURPOSE OF THIS PROJECT IS TO CLEAR & GRUB FOR ROAD AND DITCH INSTALLATION FOR A 22 LOT SINGLE FAMILY RESIDENTIAL SUBDIVISION. THE PROPERTY IS
PRIVATELY OWNED. SEE OWNER INFORMATION ON EXISTING CONDITIONS PLAN. THE SITE IS CURRENTLY UNDEVELOPED.
APPROXIMATELY 7.26 ACRES WILL BE DISTURBED DURING CONSTRUCTION. THE MAXIMUM FILL WILL BE APPROX. 3 FEET AND THE MAXIMUM CUT WILL BE APPROX. 3 FEET.
THIS PROJECT WILL INVOLVE REMOVAL OF TOPSOIL TO CREATE RESIDENTIAL ROADWAY, INFRASTRUCTURE, & STORMWATER CONVEYANCE.
THE PROJECT IS SCHEDULED TO BEGIN CONSTRUCTION IN FALL 2021 WITH PROJECT COMPLETION AND FINAL STABILIZATION BY SPRING 2022. THE EROSION AND SEDIMENT
CONTROL PROGRAM FOR THIS PROJECT WILL INCLUDE THE INSTALLATION OF A SUITABLE CONSTRUCTION ENTRANCE, TEMPORARY SILT FENCING, SILT FENCE OUTLETS, AND
DIVERSION DITCHES.
ADJACENT PROPERTY
ADJACENT PROPERTY OWNERS ARE NOTED ON THE EXISTING CONDITIONS PLAN.
NATIVE SOILS
THE SOILS AT THIS SITE ARE PREDOMINATELY LOAMY SANDS. SOILS ARE MOSTLY WELL DRAINED WITH Ksat RANGES FROM MODERATELY HIGH TO HIGH. SLOPES ARE LARGELY
BETWEEN 0% TO 10%.
1.OBTAIN A LAND-DISTURBING PERMIT FROM NCDENR.
2.SCHEDULE A PRECONSTRUCTION CONFERENCE WITH NCDENR AT LEAST ONE WEEK PRIOR TO START OF LAND DISTURBANCE.
3.CLEAR THE AREA NEEDED TO CONSTRUCT THE PROPOSED CONSTRUCTION ENTRANCE.
4.CONSTRUCT THE ENTRANCE AS SHOWN ON THE PLANS. MAINTAIN THE CONSTRUCTION ENTRANCE DAILY TO ENSURE THAT MUD AND SILT WILL NOT BE TRACKED ONTO
THE PAVED SURFACE. IF MUD IS TRACKED ONTO THE SURFACE, IT IS TO BE REMOVED IMMEDIATELY.
5.CLEAR THE AREA NEEDED TO CONSTRUCT THE REMAINDER OF PERIMETER EROSION CONTROL MEASURES.
6.INSTALL SILT FENCE, ROCKS CHECK DAMS, PLUNGE POOLS, AND TEMPORARY DIVERSIONS AS SHOWN ON THE APPROVED PLAN. SEED TEMPORARY DIVERSIONS
IMMEDIATELY AFTER CONSTRUCTION.
7.CALL NCDENR FOR AN ONSITE INSPECTION BY THE ONSITE INSPECTOR TO OBTAIN A CERTIFICATE OF COMPLIANCE.
8.BEGIN CLEARING AND GRUBBING.
9.ROUGH GRADE ALL ROADWAYS.
10.CONSTRUCT WATER AND SEWER MAINS THROUGHOUT PROJECT AS WELL AS RELOCATE THE DUKE POWER LINE.
11.GRADE DITCHES, INSTALL STORM SYSTEM AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION, BUILDING, ETC.
12.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISH GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND MULCH DENUDED AREAS WITHIN 7 OR 14
DAYS OF COMPLETION OF ANY PHASE OF CONSTRUCTION.
13.WHEN CONSTRUCTION IS COMPLETE AND ALL AREAS ARE STABILIZED COMPLETELY, CALL NCDENR ON SITE INSPECTOR.
14.IF SITE IS APPROVED, CONVERT TEMPORARY DIVERSIONS, REMOVE SILT FENCE, AND SEED OUT OR STABILIZE ANY RESULTING BARE AREAS.
15.WHEN VEGETATION HAS BECOME ESTABLISHED, CALL FOR A FINAL SITE INSPECTION BY THE ONSITE INSPECTOR. OBTAIN A CERTIFICATE OF COMPLETION.
16.SUBMIT NOTICE OF TERMINATION TO NCDENR.
·INSPECTOR REFERS TO NORTH CAROLINA LAND QUALITY INSPECTOR OR HIS REPRESENTATIVE, FIELD INSPECTIONS MAY REQUIRE ADDITIONAL SEDIMENTATION AND
EROSION CONTROL MEASURES AS DEEMED NECESSARY BY THE INSPECTOR.
·CONSTRUCTION AND MAINTENANCE OF ALL EROSION CONTROL DEVICES SHALL CONFORM TO THE STANDARDS SET FORTH IN THE NORTH CAROLINA DEPARTMENT OF
NATURAL RESOURCES LAND QUALITY SECTION: EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.
·THE CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF EROSION CONTROL MEASURES DURING CONSTRUCTION AND THE OWNER IS RESPONSIBLE FOR ALL
PERMANENT EROSION CONTROL METHODS AFTER CONSTRUCTION IS COMPLETE, IF ANY PERMANENT METHODS ARE REQUIRED.
CONSTRUCTION SEQUENCE:
THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE THAT PERSONS RESPONSIBLE FOR
LAND-DISTURBING ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED
EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES DETAILING THE DOCUMENTATION OF THESE
INSPECTIONS TOOK EFFECT OCTOBER 1, 2010.
TO SIMPLIFY DOCUMENTATION OF SELF-INSPECTION REPORTS AND NPDES SELF-MONITORING REPORTS, DWQ AND DEMLR
DEVELOPED A COMBINED FORM. THE SELF-INSPECTION PROGRAM IS SEPARATE FROM THE WEEKLY SELF-MONITORING
PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. THE FOCUS OF THE SELF-INSPECTION
REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO
THE APPROVED PLAN. THE INSPECTIONS SHOULD BE CONDUCTED AFTER EACH PHASE OF THE PROJECT, AND CONTINUED
UNTIL PERMANENT GROUND COVER IS ESTABLISHED. THE FORM CAN BE ACCESSED AT:
HTTP://PORTAL.NCDENR.ORG/WEB/LR/EROSION
IF YOU HAVE QUESTIONS OR CANNOT ACCESS THE FORM, PLEASE CONTACT THE RALEIGH REGIONAL OFFICE AT (919) 791-4200.
NOTIFICATION OF COMBINED SELF-MONITORING AND SELF-INSPECTION FORM:
EC4.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\EC4.0 EROSION CONTROL DETAILS II.DWGPLOTTED: 8/1/2022 10:26 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
EROSION CONTROL DETAILS II
1" = 60'
CONSTRUCTION SPECIFICATIONS
1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLE
MATERIAL.
2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN
REQUIREMENTS.
3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION
PLUS THE SPECIFIED SETTLEMENT.
4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND
CLEANOUT.
5. VEGETATE THE RIDGE AND CHANNEL IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL
REMAIN IN PLACE LESS THAN 30 WORKING DAYS.
CROSS SECTIONAL VIEW
2:1
M
A
X
.
2:1 MA
X.
2' MIN.
FLOW
D X
LINING, L 2:1 MAX.
2:1
M
A
X
.
10-YR MAX FLOW
GENERAL NOTES:
1.DIVERSION TO BE USED TO CONVEY SEDIMENT LADEN WATER INTO AN APPROVED EROSION AND
SEDIMENT CONTROL BMP.
2.IMMEDIATELY LINE AND STABILIZE BEFORE ANY DOWNSLOPE GRADING BEGINS (STABILIZATION MUST
OCCUR BEFORE ISSUANCE OF A CERTIFICATE OF COMPLIANCE). STABILIZATION METHOD IS BASED ON
VELOCITY OF DRAINAGE.
3.DIVERSIONS SHOULD ONLY BE USED FOR DRAINAGE AREAS 5 ACRES OR LESS.
4.MINIMUM LONGITUDINAL SLOPE OF DIVERSION SHALL BE 0.3%.
5.DEPTHS SHOWN SHALL BE FINAL AFTER SETTLEMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR
ADJUSTING DITCHES IN FIELD TO MEET DESIGN CRITERIA IF SETTLEMENT OCCURS.
6.REFER TO SKIMMER BASIN DETAIL FOR DIVERSION DITCH/SKIMMER BASIN ENTRANCE.
MAINTENANCE:
INSPECT TEMPORARY DIVERSIONS DAILY AND REPAIR, AS NECESSARY AND FOLLOWING EVERY
RAINFALL EVENT OF GREATER THAN 1/2" WITHIN A 24HR PERIOD. IMMEDIATELY REMOVE SEDIMENT
FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND
MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED,
REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND
APPROPRIATELY STABILIZE IT.
DIKE D+0.5' OR1.5' MINMIN. 0.25 FT FREEBOARD
STONE FILTER INLET PROTECTION
PLYWOOD INLET PROTECTION
GENERAL NOTE:
1.ALL PARTIALLY COMPLETED STORM DRAINS SHALL BE PROTECTED AT THE END OF EACH DAY IN ACCORDANCE WITH THESE DETAILS.
2.THIS IS NOT AN APPROVED NC METHOD OF INLET PROTECTION AND WILL ONLY BE USED TO PROTECT THE CONTRACTORS WORK
OVERNIGHT. LONGER PERIODS OF PROTECTION WILL REQUIRE THE STONE INLET PROTECTION DETAIL PER THE NCDENR ESCPDM.
BURY BOTTOM
OF PLYWOOD
UPSTREAM END OF
STORM DRAIN OVERFLOW
1/3 PIPE DIAMETER
3
4" EXTERIOR PLYWOOD
STEEL FENCE
POST (TYP.)
UPSTREAM END OF STORM DRAIN
OVERFLOW
1/3 PIPE DIAMETER
HARDWARE CLOTH
WASHED STONE FILTER
ACROSS PIPE INLET
SCALE:
1
EC4.0
TEMPORARY DIVERSION DITCH
NTS
SCALE:
2
EC4.0
PIPE INLET PROTECTOIN
NTS
SEEDBED PREPARATION:
1.CHISEL COMPACTED AREAS AND SPREAD TOPSOIL THREE INCHES DEEP
OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE.
2.RIP THE ENTIRE AREA TO SIX INCHES DEEP.
3.REMOVE ALL LOOSE ROCK, ROOTS AND OTHER OBSTRUCTIONS, LEAVING
SURFACE REASONABLY SMOOTH AND UNIFORM.
4.APPLY AGRICULTURAL LIME, FERTILIZER AND SUPERPHOSPHATE
UNIFORMLY AND MIX WITH SOIL (SEE MIXTURE).
5.CONTINUE TILLAGE UNTIL A WELL-PULVERIZED, FIRM, REASONABLY
UNIFORM SEEDBED IS PREPARED FOUR TO SIX INCHES DEEP.
6.SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY
WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING.
7.MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH.
8.INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR
RESEEDINGS WITHIN THE PLANTING SEASON,IF POSSIBLE. IF STAND
SHOULD BE MORE THAN 60% DAMAGED, RE-ESTABLISH FOLLOWING THE
ORIGINAL LIME, FERTILIZER AND SEEDING RATES.
9.CONSULT S&EC ENVIRONMENTAL ENGINEERS ON MAINTENANCE
TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS
ESTABLISHED.
SCALE:
4
EC4.0
COIR FIBER WATTLE DETAIL
NTS
MIXTURE
AGRICULTURAL LIMESTONE..........................2 TONS/ACRE (3 TONS/ACRE IN CLAY SOILS)
FERTILIZER................................................1,000 LBS/ACRE - 10-10-10
SUPERPHOSPHATE....................................500 LBS/ACRE - 20% ANALYSIS
MULCH....................................................2 TONS/ACRE - SMALL GRAIN STRAW
ANCHOR..................................................ASPHALT EMULSION AT 300 GALS/ACRE
SEEDING SCHEDULE
FOR SHOULDERS, SIDE DITCHES, SLOPES (MAX 3:1):
DATE TYPE PLANTING RATE
AUG 15 - NOV 1 TALL FESCUE 300 LBS/ACRE
NOV 1 - MAR 1 TALL FESCUE & ABRUZZI RYE 300 LBS/ACRE
MAR 1 - APR 15 TALL FESCUE 300 LBS/ACRE
APR 15-JUN 30 HULLED COMMON BERMUDAGRASS 25 LBS/ACRE
JUL 1- AUG 15 TALL FESCUE AND BROWNTOP 125 LBS/ACRE (TALL FESCUE); 35 LBS/ACRE
MILLET OR SORGHUM-SUDAN (BROWNTOP MILLET); 30 LBS/ACRE
HYBRIDS*** (SORGHUM-SUDAN HYBRIDS)
FOR SHOULDERS, SIDE DITCHES, SLOPES (3:1 TO 2:1):
DATE TYPE PLANTING RATE
MAR 1 - JUN 1 SERICEA LESPEDEZA (SCARIFIED) 50 LBS/ACRE (SERICEA LESPEDEZA);
AND USE THE FOLLOWING
COMBINATIONS:
MAR 1 - APR 15 ADD TALL FESCUE 120 LBS/ACRE
MAR 1 - JUN 30 OR ADD WEEPING LOVE GRASS 10 LBS/ACRE
MAR 1 - JUN 30 OR ADD HULLED COMMON 25 LBS/ACRE
BERMUDAGRASS
JUN 1 - SEPT 1 TALL FESCUE AND BROWNTOP 120 LBS/ACRE (TALL FESCUE);
MULLET OR SORGHUM-SUDAN 35 LBS/ACRE (BROWNTOP MULLET);
HYBRIDS*** 30 LBS/ACRE (SORGHUM-SUDAN
HYBRIDS)
SEPT 1 - MAR 1 SERICEA LESPEDEZA (UNHULLED - 70 LBS/ACRE (SERICEA LESPEDEZA);
UNSCARIFIED) AND TALL FESCUE 120 LBS/ACRE (TALL FESCUE)
NOV 1 - MAR 1 AND ABRUZZI RYE 25 LBS/ACRE
CONSULT S&EC ENVIRONMENTAL ENGINEERS FOR ADDITIONAL INFORMATION CONCERNING OTHER ALTERNATIVES FOR
VEGETATION OF DENUDED AREAS. THE ABOVE VEGETATION RATES ARE THOSE THAT DO WELL UNDER LOCAL
CONDITIONS; OTHER SEEDING RATE COMBINATIONS ARE POSSIBLE.
*** TEMPORARY: RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOW
TEMPORARY COVER TO GROW MORE THAN 12" IN HEIGHT BEFORE MOWING; OTHERWISE, FESCUE MAY BE SHADED OUT.
SCALE:
3
EC4.0
SEEDING SCHEDULE
NTS
EC5.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGIN
E
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\EC5.0 EROSION CONTROL DETAILS III.DWGPLOTTED: 8/1/2022 10:26 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
EROSION CONTROL DETAILS III
1" = 60'
SCALE:
3
EC5.0
STANDARD TEMPORARY SILT FENCE
NTS
FLOW
TRENCH WITH NATIVE BACKFILL
24" MIN.
48" HIGH MAXSTEEL POST
TRENCH WITH GRAVEL
FLOW
PONDING HT.
RUNOFF
GRAVEL
(RECOMMENDED)
FILTER FABRIC
TO UPSTREAM SIDE OF POST.
ATTACH SECURELY
4"x8" TRENCH WITH COMPACTED BACKFILL
RUNOFF
24" MIN.
9" MAX.
STORAGE HT.
8 FT MAX SPACING WITH
6 FT MAX SPACING WITHOUT
WIRE SUPPORT FENCE
WIRE SUPPORT FENCE
PONDING HT.
FLOW
8"
STEEL POST
CONSTRUCTION SPECIFICATIONS
1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT
OF POLYOLEFINS OR POLYESTER, WHICH IS CERTIFIED BY THE
MANUFACTURER OR SUPPLIER AS CONFORMING TO THE
REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART IN
TABLE 6.62B. SYNTHETIC FILTER FABRIC SHOULD CONTAIN
ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A
MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION
LIFE AT A TEMPERATURE RANGE OF 0 TO 120º F.
2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.33
LB/LINEAR FT STEEL WITH A MINIMUM LENGTH OF 5 FEET. MAKE
SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE
FASTENING THE FABRIC.
3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER
FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A
MAXIMUM MESH SPACING OF 6 INCHES.
MAINTENANCE
INSPECT SEDIMENT FENCES DAILY AND AFTER EACH RAINFALL
EVENT. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD
THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR,
DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY.
REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE
ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO
REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID
UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL
FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND
BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE
CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY
STABILIZED.
24" MAX.
NOTE: DO NOT ATTACH FABRIC
TO EXISTING TREES.
ALTERNATE DETAILSTANDARD DETAIL
FILTER FABRIC EXTRA STRENGTH NEEDED
WITHOUT WIRE MESH SUPPORT
DETAIL REFERENCE 6.62 NC ESCPDM
SCALE:
2
EC5.0
HORSESHOE INLET PROTECTION
NTS
PERSPECTIVE VIEW
SECTION THRU CATCH BASIN, FILTER AND CULVERT PIPE
#5 WASHED STONE. 1'-0" THICK x 3'-0" HIGH MINIMUM
RIP RAP HEADWALLINVERT
PIPE
CLASS 1 RIP RAP (SEE SECTION THRU BASIN BELOW)
AREAS TO BE DISTURBED
(CUT, FILL, ETC.)
SEDIMENT STORAGE
FLOOD STORAGE ZONE
PIPE
INVERT
RIP RAP
HEADWALL
NATURAL GROUND
CLASS 1 RIP-RAP
#5 WASHED STONEMAXIMUM SEDIMENT DEPTH
(CLEAN OUT POINT)
4'-6'
9" MIN.
EDGE OF PAVEMENT
SHLD.
DITCH CHECK
TEMP. STONE
SLO
PEDITC
H
PAVEME
N
T
NATURAL GROUND
FLOW
NATURAL GROUND
SLOPE
BACK
9" MIN.
ISOMETRIC VIEW CROSS SECTION
VEE DITCH
CLASS 'B' RIP-RAP
CROSS SECTION
FOUNDATION.
TRAPEZOIDAL DITCH
CONSTRUCTION SPECIFICATIONS
WHERE THE DAM ABUTS THE CHANNEL BANKS.
ELEVATION VIEW
BASE OF DITCH
1. PLACE STONE TO THE LINES AND DIMENSIONS SHOWN IN THE PLANS ON A FILTER FABRIC
2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL
STRUCTURE).
FROM UNDERCUTTING THE DAM AS IT RE-ENTERS THE CHANNEL.
LOWER DAM IS THE SAME AS THE TOE ELEVATION OF THE UPPER DAM.
DAMS, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES.
3. EXTEND STONE AT LEAST 1.5 FT. BEYOND THE DITCH BANKS TO KEEP OVERFLOW WATER
4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AT THE TOP OF THE
5. PROTECT THE CHANNEL DOWNSTREAM FROM THE LOWEST CHECK DAM, CONSIDERING THAT
WATER WILL FLOW OVER AND AROUND THE DAM (PRACTICE 6.41, OUTLET STABILIZATION
6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE.
7. ENSURE THAT CHANNEL APPURTENANCES, SUCH AS CULVERT ENTRANCES BELOW CHECK
(REFERENCE: EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, 6.83)
OR #57 WASHED STONE
1' THICK NCDOT #5
2' MAX AT
CENTER
9" MIN.
CLASS 'B' RIP-RAP
SCALE:
1
EC5.0
ROCK CHECK DAM
NTS
SCALE:
4
EC5.0
BLANKET ON CHANNELS
NTS
INSTALLATION OF EROSION CONTROL
NOTES:
1.PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECPS), INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER,
AND SEED.
2.BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE RECPS IN A 6"(15CM) DEEP X 6"(15CM) WIDE TRENCH WITH APPROXIMATELY 12"(30CM) OF
RECPS EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. USE SHOREMAX MAT AT THE CHANNEL/CULVERT OUTLET AS SUPPLEMENTAL
SCOUR PROTECTION AS NEEDED. ANCHOR THE RECPS WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12"(30CM) APART IN THE BOTTOM OF THE
TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO THE COMPACTED SOIL AND FOLD THE REMAINING 12"(30CM)
PORTION OF RECPS BACK OVER THE SEED AND COMPACTED SOIL. SECURE RECPS OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES
SPACED APPROXIMATELY 12" APART ACROSS THE WIDTH OF THE RECPS.
3.ROLL CENTER RECPS IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL. RECPS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL
SURFACE. ALL RECPS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE
STAPLE PATTERN GUIDE.
4.PLACE CONSECUTIVE RECPS END-OVER-END (SHINGLE STYLE) WITH A 4"-6" OVERLAP. USE A DOUBLE ROW OF STAPLES STAGGERED 4" APART AND 4"
ON CENTER TO SECURE RECPS.
5.FULL LENGTH EDGE OF RECPS AT TOP OF SIDE SLOPES MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12"(30CM) APART IN A
6"(15CM) DEEP X 6"(15CM) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING.
6.ADJACENT RECPS MUST BE OVERLAPPED APPROXIMATELY 2"-5" (5-12.5CM) (DEPENDING ON RECPS TYPE) AND STAPLED.
7.IN HIGH FLOW CHANNEL APPLICATIONS A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT (9 -12M) INTERVALS. USE A DOUBLE ROW OF
STAPLES STAGGERED 4"(10CM) APART AND 4"(10CM) ON CENTER OVER ENTIRE WIDTH OF THE CHANNEL.
8.THE TERMINAL END OF THE RECPS MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30CM) APART IN A 6"(15CM) DEEP X
6"(15CM) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING.
2"-5"
(5-12.5cm)
6
2
4
6"
(15cm)
6"
(15cm)
4"-6"
(10-15cm)
8
6"
(15cm)
5 7
4"(10cm)
3
1
A
B
C
NOTES:
*HORIZONTAL STAPLE SPACING SHOULD BE ALTERED IF
NECESSARY TO ALLOW STAPLES TO SECURE THE CRITICAL
POINTS ALONG THE CHANNEL SURFACE.
**IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE
LENGTHS GREATER THAN 6"(15CM) MAY BE NECESSARY TO
PROPERLY SECURE THE RECP'S.
C
CRITICAL POINTS
A. OVERLAPS AND SEAMS
B. PROJECTED WATER LINE
C. CHANNEL BOTTOM/SIDE SLOPE VERTICES
4"(10cm)
6"
B
(15cm)
A
3' FILTER FABRIC
ON GROUND
STEEL FENCE POST
WIRE FENCE
HARDWARE CLOTH
FILTER OF #57
WASHED STONE
BURY 6" OF UPPER EDGE OF
FILTER FABRIC IN TRENCH
TOP OF SILT FENCE
MUST BE AT LEAST 1'
ABOVE THE TOP OF
THE WASHED STONE
SILT FENCE
FRONT VIEW
SECTION VIEW
STEEL FENCE POST
SET MAX 2' APART
MIN. 18" INTO SOLID
GROUND
BURY WIRE FENCE,
FILTER FABRIC,
AND HARDWARE
CLOTH IN TRENCH
4' MIN.
NOTES:
1.REMOVE SEDIMENT WHEN HALF OF STONE OUTLET IS COVERED.
2.REPLACE STONE AS NEEDED TO ENSURE DEWATERING.
SCALE:
5
EC5.0
STANDARD SILT FENCE OUTLET
NTS
BURY WIRE FENCE
AND HARDWARE
CLOTH
SCALE:
6
EC5.0
STANDARD CONSTRUCTION ENTRANCE
NTS
50' MIN.EXISTING PAVED ROADWAYA
AGGREGATE
2"-3" COURSE
MIN. 6" THICK
DIVERSION RIDGE
A20' RROADWAY
EXISTING PAVED
DIVERSION RIDGE
GEOTEXTILE FABRIC
CONSTRUCTION SPECIFICATIONS
1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION,
ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY
GRADE IT.
2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS
SHOWN ON THE PLANS, AND SMOOTH IT.
3. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP
OR OTHER SUITABLE OUTLET.
4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY
OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR
HIGH WATER TABLE.
MAINTENANCE
MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR
SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY
REQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. AFTER
EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP
SEDIMENT DAILY AND CLEAN IT OUT AS NECESSARY.
IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED,
WASHED, OR TRACKED ONTO PUBLIC ROADWAYS.
SECTION A-A
PLAN VIEW
DETAIL REFERENCE 6.06 NC ESCPDM
20'
EC6.0
E N GI N E ERI N G
Curry 205 S. Fuquay Avenue
Fuquay-Varina, NC 27526
(919) 552-0849
(919) 552-2043CURRY E NGINE
E
RSNOR
TH CA R O L INAEST.1 0
NC LIC. NO. P-0799
T
F
Z:\PROJECTS FOLDER-ZEBULON\2021\2021-026 HAL LONG SUBDIVISION - HARNETT COUNTY\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\EC6.0 EROSION CONTROL DETAILS IV.DWGPLOTTED: 8/1/2022 10:26 AMPROFESSIONAL'S SEAL
DATE:
FILE NO.
HORZ. SCALE:
ORIG. SHEET SIZE:
REVISIONS
24 x 36
STATUS
CONSULTANT CLIENT CONSTRUCTION DRAWINGS
MASON LANDING SUBDIVISION
AUGUST 20, 2021
2021-026
RELEASED
FOR CONSTRUCTION
Long Land Development, LLC
9404 Northfield Ct.
Raleigh, NC 27603
919-810-6151 (m)
Contact: Hal Long
hallong@att.net
01 / 14 / 20221 NCDEQ COMMENT REVISION
01 / 26 / 20222 HRW COMMENT REVISION
02 / 01 / 20223 NCDOT COMMENT REVISION
02 / 25 / 20224 HRW COMMENT REVISION
03 / 09 / 20225 HRW COMMENT REVISION
03 / 25 / 20226 NCDEQ PWSS COMMENT REVISION
03 / 30 / 20227 RELEASED FOR CONSTRUCTION
07 / 08 / 20228 HARNETT PLANNING COMMENT REVISION
EROSION CONTROL DETAILS IV