Loading...
HomeMy WebLinkAboutHayes Pointe _Plan Set_revised 10.27.221 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 31 30 29282726252423 21 33 32 20 22 34 35 36 TWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03 TOM HUGH JOHNSONDEED BOOK 3945, PAGE 126PLAT CABINET F, SLIDE 305-DPLAT CABINET 2, SLIDE 247PLAT BOOK 98, PAGE 271PIN: 0524-57-0707.000PID: 010524 0069 08 TWO ADAMS, INCDEED BOOK 2202, PAGE 811PIN: 0524-69-2768.000PID: 010536 0105HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)OVERALL PLAN ENGINEERING, PLLCHILLIARD 3417 Winterwind Circle, Sanford, NC 27330 PO Box 249, Sanford, NC 27331 Phone: (919) 352-2834 e-mail: jhilliard@hilliardengineering.com NC License #: P-0836 OWNER TOMMY LYNN MCPHAIL AND WIFE,BONNIE H. MCPHAIL174 FARRAR ROADLILLINGTON, NC 27546 GENERAL NOTES:(REFERENCE SHEET C4.5 FOR HRW WATER AND SEWER STANDARD NOTES.) 1. ALL WORK SHALL COMPLY WITH HARNETT COUNTY AND NCDOT STANDARDS AND SPECIFICATIONS. 2. THIS PROJECT IS SERVED BY PUBLIC WATER AND PUBLIC SEWER OWNED, MAINTAINED ANDOPERATED BY HARNETT REGIONAL WATER. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES AND REPAIRING ANYDAMAGE TO SAME. UTILITY LOCATIONS AS SHOWN ON PLANS ARE APPROXIMATE AND MAY NOT BECOMPLETE. THE CONTRACTOR SHALL HAVE NORTH CAROLINA ONE CALL (1-800-632-4949) LOCATEALL EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. 4. PROVISIONS SHALL BE MADE TO ENSURE POSITIVE DRAINAGE ON THE SITE AT ALL TIMES. NATURALDRAINAGE FEATURES DISTURBED BY CONSTRUCTION MUST BE RE-ESTABLISHED. NO PONDING DUETO SPOILS STOCKPILING OR OTHER ACTIVITIES SHALL BE PERMITTED. 5. WORK IN PUBLIC RIGHT-OF-WAYS OR PRIVATE EASEMENTS SHALL BE ACCOMPLISHED BY THECONTRACTOR ACCORDING TO THE REQUIREMENTS OR CONDITIONS OF THE ENCROACHMENT PERMITOR OTHER LEGAL DOCUMENTS AS THOUGH DOCUMENTS WERE ISSUED IN THE CONTRACTOR NAME.THE CONTRACTOR SHALL MAINTAIN COPIES OF THESE DOCUMENTS ON THE SITES AT ALL TIMES. 6. WHEN THE CONTRACTOR IS UNABLE TO COMPLETE HIS WORK AS SHOWN ON THE PLANS BECAUSE OFAN EXISTING UTILITY, CONTRACTOR SHALL STAKE THE LOCATION OF THE UTILITY PRIOR TOPROCEEDING AND CONTACT THE ENGINEER. 7. THE CONTRACTOR SHALL NOTIFY ALL PUBLIC AGENCIES, THE OWNER, THE ENGINEER AND ALL OTHERCONCERNED PARTIES WHEN CONSTRUCTION IS TO COMMENCE. PRIOR TO ANY CONSTRUCTION APRECONSTRUCTION MEETING SHALL BE HELD WITH THE MUNICIPALITY / AUTHORITY, THECONTRACTOR, THE ENGINEER AND ANY OTHER INTERESTED PARTY. 8. DATA REQUIRED FOR PREPARATION OF RECORD DRAWINGS SHALL BE OBTAINED BY THECONTRACTOR AT THE TIME FOR INSTALLATION. DATA SHALL BE ACCUMULATED BY THE CONTRACTORDURING THE CONSTRUCTION PERIOD AND PROVIDED TO THE ENGINEER UPON COMPLETION OF THEPROJECT 9. INSPECTIONS SHALL BE CONDUCTED IN ACCORDANCE WITH ALL APPLICABLE HARNETT COUNTY,NCDNER AND NCDOT STANDARDS. 10. ALL EXCAVATED EXCESS OR WASTE SOILS AND MATERIAL SHALL BE REMOVED FROM THE SITE BYCONTRACTOR EXCEPT AS SPECIFICALLY APPROVED IN WRITING BY BOTH THE ENGINEER AND OWNER. 11. WHEN CONCRETE SIDEWALKS, CURB AND GUTTER SECTIONS OR ASPHALT PAVEMENT ARE DAMAGEDDUE TO CONSTRUCTION ACTIVITIES, THEY SHALL BE REPLACED IN A TIMELY MANNER BY THECONTRACTOR TO ASSURE THE CONTINUED USE OF THESE FACILITIES BY ALL CONCERNED. 12. CONTRACTOR IS TO COMPLY WITH ALL PROVISIONS OF THE MANUAL OF UNIFORM TRAFFIC CONTROLDEVICES WHEN WORKING ADJACENT TO AN EXISTING PUBLIC HIGHWAY RIGHT OF WAY. 13. THE CONTRACTOR WILL MAINTAIN ALL EXISTING ROADS IN A NEAT AND CLEAN CONDITIONTHROUGHOUT THE COURSE OF THE PROJECT CONSTRUCTION. REVISION OCCURRENCE LIST 2 10/24/2022 PER DRM AND NCDOT COMMENTS 1 8/28/2022 PER DRM COMMENTS REVISION NO. DATE REVISION DESCRIPTION BY THIS SET IS CURRENT THROUGH SHEET DATED: OCTOBER 24, 2022 SHEET SCHEDULE SHEET TITLE SHEET NO:ORIGINAL DATE LATEST REVISION DATE COVER SHEET 01 JULY 14, 2022 OCTOBER 24, 2022 EXISTING CONDITION C 1.0 JULY 14, 2022 AUGUST 28, 2022 SITE PLAN C 2.0 JULY 14, 2022 OCTOBER 24, 2022 EROSION CONTROL PLAN - INITIAL PHASE C 3.0 JULY 14, 2022 - EROSION CONTROL PLAN - CONSTRUCTION PHASE C 3.1 JULY 14, 2022 - EROSION CONTROL PLAN - FINAL PHASE C 3.2 JULY 14, 2022 - EROSION CONTROL GROUND STABILIZATION AND SELFINSPECTION NOTE C 3.3 JULY 14, 2022 - EROSION CONTROL NOTE C 3.4 JULY 14, 2022 - EROSION CONTROL DETAIL C 3.5 JULY 14, 2022 - EROSION CONTROL DETAIL C 3.6 JULY 14, 2022 - EROSION CONTROL DETAIL C 3.7 JULY 14, 2022 - SANITARY SEWER & WATER LINE PLAN; SAN SEW PROFILE C 4.0 JULY 14, 2022 OCTOBER 24, 2022 SANITARY SEWER & WATER LINE PLAN; SAN SEW PROFILE C 4.1 JULY 14, 2022 OCTOBER 24, 2022 SANITARY SEWER & WATER LINE PLAN; SAN SEW PROFILE C 4.2 JULY 14, 2022 OCTOBER 24, 2022 SANITARY SEWER & WATER LINE PLAN; SAN SEW PROFILE C 4.3 JULY 14, 2022 OCTOBER 24, 2022 WATER LINE PROFILES C 4.4 JULY 14, 2022 OCTOBER 24, 2022 HARNETT COUNTY STANDARD UTILITY NOTES C 4.5 JULY 14, 2022 AUGUST 28, 2022 SANITARY SEWER DETAIL C 4.6 JULY 14, 2022 - SANITAYR SEWER DETAIL C 4.7 JULY 14, 2022 - WATER DETAIL C 4.8 JULY 14, 2022 AUGUST 28, 2022 WATER DETAIL C 4.9 JULY 14, 2022 AUGUST 28, 2022 ROADWAY PLAN AND PROFILE C 5.0 JULY 14, 2022 OCTOBER 24, 2022 ROADWAY PLAN AND PROFILE C 5.1 JULY 14, 2022 OCTOBER 24, 2022 ROADWAY PLAN AND PROFILE C 5.2 JULY 14, 2022 OCTOBER 24, 2022 ROADWAY PLAN AND PROFILE C 5.3 JULY 14, 2022 OCTOBER 24, 2022 ROADWAY PLAN AND PROFILE C 5.4 JULY 14, 2022 OCTOBER 24, 2022 OVERALL STORM DRAINAGE PLAN C 6.0 -OCTOBER 24, 2022 STORM DRAINAGE PROFILES C 6.1 JULY 14, 2022 OCTOBER 24, 2022 STORM DRAINAGE PROFILES C 6.2 JULY 14, 2022 OCTOBER 24, 2022 SITE DETAIL C 7.0 JULY 14, 2022 - SITE DETAIL C 7.1 JULY 14, 2022 - STORMWATER MANAGEMENT DETAIL C 8.0 JULY 14, 2022 OCTOBER 24, 2022 LANDSCAPE PLAN AND DETAIL L 1.0 JULY 14, 2022 OCTOBER 24, 2022 NORTH HAYES POINTE RESIDENTIAL DEVELOPMENT 0' SCALE IN FEET 50 100 200 NORTHBUDDYBAREFOOT RD2049 BETHEL BAPTIST RD2048 HAYES RD2047 BILLSHAW RD1144 SITE VICINITY MAPNOT TO SCALE SPRING LAKE, NORTH CAROLINA DEVELOPER LAND 2020, INC.350 WAGONER DRIVEFAYETTEVILLE, NC 28303 AS THE OWNER OF RECORD, I HEREBY FORMALLYCONSENT TO THE PROPOSED DEVELOPMENT SHOWN ONTHIS SITE PLAN AND ALL REGULATIONS ANDREQUIREMENTS OF THE HARNETT COUNTY ORDINANCES ________________________________________________OWNER SIGNATURE _________________DATE WATER/SEWER CAPACITY NOTE: APPROVAL OF THE PLAT/PLAN DOES NOT GUARANTEE WATER ORSEWER TREATMENT CAPACITY. CURRENT/FUTURE CAPACITY MAYNOT BE AVAILABLE. THIS DEVELOPMENT MAY REQUIRE ADDITIONALIMPROVEMENTS TO THE EXISTING WATER SYSTEM OR SEWERSYSTEM TO MEET FUTURE WATER AND SEWER DEMANDS PRIOR TOA PRELIMINARY PLAY, CONSTRUCTION PLAN AND/OR FINAL PLATAPPROVAL. STANDARD MAINTENANCE NOTE: SIDEWALKS AND STREET TREE ARE TO BE MAINTAINED BY THE HOMEOWNERS ASSOCIATION ("HOA"), PROPERTY OWNERS ASSOCIATION("POA"), CONDOMINIUM OWNERS ASSOCIATION ("COA"), OR ANYOTHER ASSOCIATION RESPONSIBLE FOR THE MAINTENANCE AND/ORUPKEEP OF THE RESIDENTIAL COMMUNITY. SIDEWALK OR STREETTREE INSTALLATIONS THAT ARE DAMAGED AND/OR REMOVED BYHARNETT COUNTY/DEPARTMENT OF PUBLIC UTILITIES/HARNETTREGIONAL WATER OR ITS REPRESENTATIVE AGENTS, ORCONTRACTORS AS A RESULT OF REPAIR/MAINTENANCE OF THEPUBLIC WATER AND/OR SEWER LINE WILL BE REPLACED OR REPAIREDBY THE HOME OWNERS ASSOCIATION ("HOA"), PROPERTY OWNERSASSOCIATION ("POA"), CONDOMINIUM OWNERS ASSOCIATION("COA"), OR ANY OTHER ASSOCIATION RESPONSIBLE FOR THEMAINTENANCE AND/OR UPKEEP OF THE RESIDENTIAL COMMUNITY. BLACK FOREST DRIVE BOOKRAND LANESTEPPING STONE LANE 171LINE BEARING DISTANCE L1 N 86°39'20" W 57.16' L2 N 86°39'20" W 135.01' L3 N 86°39'20" W 135.01' L4 N 86°39'20" W 74.51' 1,045.52'TWO ADAMS, INCDEED BOOK 2202, PAGE 811PIN: 0524-69-2768.000PID: 010536 0105617.23'98.46'W-2W- 3 77.85'W- 4 W-1RCP906.62'N 88°01'02" E 715.69' TOTALLINE BEARING DISTANCEW-1 S 17°32'52" W 16.53' W-2 S 39°20'01" W 42.28' W-3 S 61°53'43" W 30.27' W-4 S 66°47'03" W 46.84' CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLEC1 2421.00' 106.77'106.76'N 87°55'09" W 2°31'36" C2 6600.00' 60.49'60.49'N 86°55'06" W 0°31'30" C3 6600.00' 135.29'135.29'N 87°46'05" W 1°10'28" OHU OHUTIES 02°48'51" W 30.02'C1RUSSELL LYNN HAYESNO DEED FOUNDPIN: 0524-67-1662.000PID: 010524 0063 L2L1OHUL3HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)C2L4OHURCPPHONEPEDESTAL C3TIEN 02°18'21" E30.00'OHU TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL DEED BOOK 684, PAGE 606 PIN: 0524-58-4260.000PID: 010534 0079 01 WATER VALVEOHU SSTIES 89°18'20" E 136.53'KRISTA HERNANDEZ DEED BOOK 3971, PAGE 938 PLAT BOOK 2001, PAGE 833 PIN: 0524-57-0707.000 PID: 010524 0069 08 FEDERAL NATIONAL MORGAGE DEED BOOK 3882, PAGE 330 PLAT BOOK 2002, PAGE 1445 PIN: 0524-47-8778.000 PID: 010524 0069 07 S 02°48'51" W 1.075.54' TOTAL N 02°18'21" E 1,014.47' TOTAL TWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03 TOM HUGH JOHNSON DEED BOOK 3945, PAGE 126 PLAT CABINET F, SLIDE 305-DPLAT CABINET 2, SLIDE 247PLAT BOOK 98, PAGE 271PIN: 0524-57-0707.000PID: 010524 0069 08 169 168 1 6 8 167166 16 4 16516616416 3 162 161 15 9 1 5 8 165160 16816 7 169168 167 16 6 164 163 162 16 1 16 5 160 168 167 16 6 164 163 162 16115 9 15 8 1 6 5 160 1 6 9 169 169168 16 7 1681 6 8168168168168169 169 16916916916916 9 169 169169169 168167169 168167 170169 168167169169169 168 167 166166167168169169169169 16 9 169 169 16917173170171170170172171172171172172171172170170170170170169 1691 7 0170170RCPRCPRCPRCP RCPRCP16" GRAVITY FEED SANITARY SEWER EXISTING SOIL DRIVE EXISTING 40' UTILITY EASEMENT 20' EITHER SIDE OF CENTER OF UTILITIES - DETERMINED BY CLEARING LIMITS - IRON 3/4 IRON 3/4 DELINATED WETLAND 5,183 SF (ELEV = 158.1') EX NAIL IN PINE KNOT FOUND IN WET AREA APPROXIMATE LOCATIONOF FEMA FLOOD ZONE ZONE AE BASE FLOOD ELEVETION = 158.9' EX. DRAINAGE CHANNEL >> EXISTING GRAVEL DRIVE EX 30' ACCESS EASEMENT PLAT BOOK 98, PG 271 CONC.MONUMENT EXISTING 30' UTILITY EASEMENT 15' EITHER SIDE OF 16" GRAVITY FEED SANITARY SEWER 16" GRAVITY FEED SANITARY SEWEREXISTING 30' UTILITY EASEMENT 15' EITHER SIDE OF UTILITY - DETERMINED BY CLEARING LIMITS - EX. SANITARY FORCE MAIN 30' SEWER EASEMENT 6" WATER LINE PER GISEX. DRAINAGE CHANNEL IRON 5/8" N:548092.95 E:2025804.67 N:548128.77 E:2025101.13 RCPEX. OVERHEAD POWER LINE SSMH RIM = 168.60 INV = 147.66 SSMH RIM = 168.50INV = 148.06 SSMH RIM = 168.85INV = 148.45 SSMH RIM = 168.08 INV = 148.98 SSMH RIM = 127.27 INV = 149.22 SSMH RIM = 173.39 INV = 149.29 NORTH 0' SCALE IN FEET 25 50 100 NORTHBUDDYBAREFOOT RD2049 BETHEL BAPTIST RD2048 HAYES RD2047 BILLSHAW RD1144 SITE Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONVICINITY MAPNOT TO SCALE DASHED BOUNDARY LINESLINES NOT SURVEYED; INFORMATION OBTAINED BY DEEDSAND/OR PLATS OF RECORD AS NOTED NCGS/USGS GRID TIENO CONTROL MONUMENTS RECOVERED WITHIN 2,000 FEETOF SITE WATERLINE LOCATION PER COUNTY GIS ALL AREAS CALCULATED BY COORDINATEMETHOD UNLESS OTHER WISED NOTED REFERENCES: DEED BOOK 684, PAGE 606 PIN: 0524-87-7885.000 PID: 010534 0079 REID: 0023189 CURRENT OWNERS TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL 174 FARRAR ROAD LILLINGTON, NC 27546 TOTAL AREA SURVEYED 17.002 ACRES CALCULATED BYCOORDINATE METHOD GENERAL NOTES:1. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH ALL HARNETTCOUNTY AND NCDOT STANDARDS. 2. CONTRACTOR IS TO VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO ANDDURING CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ENGINEER. 3. A PORTION OF THE PROPERTY SHOWN HEREON IS LOCATED IN A SPECIALFLOOD HAZARD AREA, ZONED AE , BASED FLOOD ELEVATION, 158.9', ASDETERMINED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY. FLOOD HAZARD: ZONE X (REMAINDER OF PROPERTY)MAP: 3720052400K ~ PANEL: 0524EFFECTIVE: 5 JANUARY 2007 4. CONTRACTOR SHALL LOCATE AND VERIFY DEPTHS OF ALL EXISTINGUTILITIES PRIOR TO BEGINNING CONSTRUCTION AND NOTIFY THE ENGINEEROF ANY DISCREPANCIES OR CONFLICTS PRIOR TO BEGINNING CONSTRUCTION. 5. CONTRACTOR IS REQUIRED TO MEET ALL APPLICABLE LOCAL, STATE ANDFEDERAL REGULATIONS AND ASSUMES FULL RESPONSIBILITY FORCOMPLIANCE. 6. ALL DEBRIS FROM DEMOLITION OPERATIONS SHALL BE DISPOSED OF OFFSITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. 7. ALL EXISTING PAVEMENT EDGES SHALL BE SAW CUT TO A STRAIGHT EDGE. 8. UTILITIES TO REMAIN IN PLACE SHALL BE PROTECTED FROM DAMAGE.CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES. 9. CONTRACTOR SHALL COORDINATE ALL DEMOLITION OPERATIONS WITHGOVERNING AGENCIES AND UTILITY COMPANIES. SURVEY NOTES: BOUNDARY SURVEY AND EXISTING FEATURES PROVIDED BY : ATLAS SURVEYING & MAPPING1503 OLD CARBONTON ROADSANFORD, NORTH CAROLINA.STEVEN W. MULLINS, PLSNC. LICENSE NO. 4740 EXISTING CONDITIONC1.0 WWWW W W W WWSS SS SS SS SS SS 171.43' 171.43' 171.43' 171.43' 171.43' 171.43' 171.43'70.00'70.00'70.00'70.00'70.00'70.00'171.43'171.43'171.43'171.43'171.43'173.50'173.19'172.75'172.31'171.88'26 . 4 0 ' 57.45'23.60'81.05'81.05'81.05'81.05'62.87' OPEN SPACE 81.05'81.05'81.05'81.05'65.36'26.92'SSSSSSSSSSSSSSSS 70.00'70.00'70.00'70.00'70.00'OPEN SPACE76.75'413726 SF0.32 Ac513948 SF0.32 Ac613983 SF0.32 Ac714019 SF0.32 Ac814053 SF0.32 Ac914003 SF0.32 Ac1013962 SF0.32 Ac1113894 SF0.32 Ac1213894 SF0.32 Ac1313894 SF0.32 Ac1413894 SF0.32 Ac1513894 SF0.32 Ac1612008 SF0.28 Ac1712000 SF0.28 Ac1812000 SF0.28 Ac1912000 SF0.28 Ac2012000 SF0.28 Ac2112000 SF0.28 Ac3012829 SF0.29 Ac2912033 SF0.28 Ac2812000 SF0.28 Ac2712000 SF0.28 Ac2612000 SF0.28 Ac2512000 SF0.28 Ac2412000 SF0.28 Ac2312000 SF0.28 Ac2212041 SF0.28 ACc3,944 SF115897 SF215876 SF315880 SF0.09 Ac70.25'171.43'98.61'98.61'160.99'145.45'25.59'3512000 SF0.28 Ac3612369 SF0.28 AcOPEN SPACE 8,576 Sq. Feet0.20 Ac OPEN SPACE 24,168 Sq. Feet0.55 Ac171.43'171.43'171.43'171.43'171.43'3412000 SF0.28 Ac3312000 SF0.28 Ac3212000 SF0.28 Ac3112000 SF0.28 Ac132.83'114.35'135.71' 141. 2 1 ' 14 6 . 0 7 ' 15 0 . 2 3 '119.97 '115.23'126.20' 55.50'105.12'82.73'160.97'129.75'65.35'94.60'70.50'70.00'70.00'70.00'70.00'70.00'70.00'70.14'99.20'74.46'69.43'67.66'98.76'96.65'1 1 2 .7 4 '165.86' 44.45'27.01'2 0 .7 1 '35.74'1 7 .08'68.94'23.81'46.38'81.05'81.05'81.05'81.05'81.05'81.06'144.89'154.23'129.35'70.00'70.00'70.00'70.00'86.41'133.10 ' 28.10' 113,337 SF2.60 Ac 50.00'50.25'50.01'WWWWWWWW W W81.05' 2 7 . 4 7 ' 27.75'156160158168167166165164163162156157161160159158167166165164163162 156158 168 161TWO ADAMS, INC DEED BOOK 2202, PAGE 811 PIN: 0524-69-2768.000 PID: 010536 0105 WWWWWWWWRUSSELL LYNN HAYESNO DEED FOUNDPIN: 0524-67-1662.000PID: 010524 0063HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)TOMMY LYNN MCPHAIL AND WIFE,DEED BOOK 684, PAGE 606DEED BOOK 3971, PAGE 938PLAT BOOK 2001, PAGE 833TWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03TOM HUGH JOHNSONDEED BOOK 3945, PAGE 126PLAT CABINET F, SLIDE 305-DPLAT CABINET 2, SLIDE 247PLAT BOOK 98, PAGE 271PIN: 0524-57-0707.000PID: 010524 0069 0810.0' DRNESMT. 20.0' DRN. &OPEN SPACEESMT.NORTH0' SCALE IN FEET 25 50 100 LOT LOT VARIES UTILITYESMT. 50' ROW ROW - VARIES NOTES: 1. RADII DIMENSIONS ARE TO EDGE OF PAVEMENTUNLESS OTHERWISE NOTED. 2. ALL ROADWAY FOLLOWS NCDOT SUBDIVISIONROAD STANDARDS UNLESS OTHERWISE NOTED. 3. DEVELOPMENT SHALL COMPLY WITH HARNETTCOUNTY ZONING AND LAND DEVELOPMENTREGULATIONS, LATEST EDITIONS. 4. CONTRACTOR SHALL INSTALL A STOP SIGN AT THEINTERSECTION WITH HAYES ROAD AND AT THE ENDOF EACH OF THE STUB ROAD IN ACCORDANCE WITHNCDOT SPECIFICATION. STANDARD DUTY ASPHALT PAVEMENT (SEE DETAIL) CONCRETE SIDEWALK (SEE DETAIL) GENERAL INFORMATION PROJECT PROPOSAL: RESIDENTIAL SUBDIVISION: HAYES POINTE HAYES ROAD (SR 2047) 535 HAYES ROAD SPRING LAKE, NC 28390 ZONINGZONING: RA-20RMINIMUM LOT SIZE: 12,000 SQ. FT. (COMPATIBILITY DESIGN CONCEPT) MINIMUM LOT SIZE PROVIDED: 12,000 SQ. FT. LAND USE CLASS: LOW DENSITY PROPERTY ID NUMBERS PIN: 0524-58-4260-0000 PID: 010534 0079 01 DEED BOOK & PAGE: 96E-0239 TOTAL EXISTING TRACT = 17.0 AC PROPOSED NUMBER OF LOTS = 36 SETBACKSFRONT: 25' BACK: 20' SIDE: 10' SIDE @ EXISTING OR PROPOSED ROAD: 20' MINIMUM LOT WIDTH / FRONTAGE: 70' IMPERVIOUS AREA: (3.70 AC TOTAL; 21.83%IMPERVIOUS OF PROPERTY SIZE) HOMES AND DRIVEWAY = 91,620 SF (2,545 SF/LOT, MAX. PER LOT)ROADS INCLUDING CURBS = 59,387 SF STREET NAME MAIN = 955 LF STREET NAME A = 510 LF STREET NAME B = 513 LF SIDEWALK AND MAIL KIOSK = 10,665 SF TOTAL IMPERVIOUS = 161,672 SFWET POND DRAINAGE AREA = 14.61 ACIMPERVIOUS AREA OF D.A. = 25.40% DAILY DESIGN FLOW: WATER: 400 GPD/LOT X 36 LOTS = 14,400 GPD SEWER: 360 GPD/LOT X 29 LOTS = 10,440 GPD (3 BEDROOM LOTS) SEWER: 480 GPD/LOT X 7 LOTS = 3,360 GPD (4 BEDROOM LOTS) 10' SIDE 20' CORNER 10' 10'25'25' FRONT20'BUILDING SETBACKS N.T.S.20' REARTYPICAL LOCAL RESIDENTIAL ROAD CROSS SECTION 3.0% CL 24' PAVEMENT WIDTH 3.0% 50' R.O.W. RW RW 2.0% CURB & GUTTER 2.0% 12.0' 2: 1 ( M A X ) 2:1 ( M A X) 5.0' SIDEWALK 2: 1 ( M A X ) 2:1(M A X) NOT TO SCALE 2.0'3.5 10.5' SITE LEGEND NORTH10' X 70'SITE TRIANGLE (TYP BOTH SIDES) STOP SIGN: SEE NOTE 4THIS SHEET 30" ROLLED CURBAND GUTTER (TYP) GRASS Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONVICINITY MAP BUDDYBAREFOOT RD2049 BETHEL BAPTIST RD2048 HAYES RD2047 BILLSHAW RD1144 NOT TO SCALE SITE 12.0' CURB & GUTTER 30" VALLEY R30' (TYP.) 24.0'EOP-EOP 50.0'ROWR30.0'(TYP.)EXISTINGDRAINAGE CHANNEL 5.0' CONC.SIDEWALK (TYP.) PROPOSED 3/4" WATER SERVICE(TYP.) PROPOSED 4" SEWER SERVICE(TYP.) R35.0'EOP R45.0' ROW PROPOSE DETENTIONPONDWITH FOREBAY 10.0' SIDE SETBACK (TYP) 20.0'REAR SETBACK 25.0'FRONT SETBACK 4.0' x 4.0' CONC.PAD FOR MAIL KIOSK STORM DRAINAGESYSTEMS AND CURBINLETS (TYP) PROPOSED 6" PVC WATER MAIN PROPOSED ADARAMP CROSSWALKWITH DETECTABLE WARNING DOME(TYP OF ALL) EX. 16" SANITARY SEWER MAIN EX 6" WATERLINE TIE TO EXISTING 6" WATERLINE PROPOSED 6" PVC WATER MAIN EX. 16" SANITARY SEWER MAIN EX. SEWER FORCE MAIN EX. GRAVAL ROAD EX. GRAVAL ROAD EX. SEWER FORCE MAIN EX. GRAVAL ROAD EX. HYDRANT AND WATER VALVE EX. STORM DRAINS (TYP.) EX. PHONE PEDESTAL R30.0'TYP. 30' EXISTING 40' UTILITY EASEMENT 20' EITHER SIDE OF CENTER OF UTILITIES - DETERMINED BY CLEARING LIMITS - EXISTING 30' UTILITY EASEMENT 15' EITHER SIDE OF 16" GRAVITY FEED SANITARY SEWER END ROAD ATPROPERTY BOUNDARY END ROAD AT PROPERTY BOUNDARY EX. SANITARY SEWER MANHOLE EX. SANITARY SEWER MANHOLE SITE LAYOUT PLANC2.0PER DRB COMMENTS 8/28/2022 6" ABC TEMPORARYTURN-AROUND 10.0' DRN.ESMT. PROPOSED FIRE HYDRANT PROPOSEDFIRE HYDRANT PROPOSEDFIRE HYDRANT 30" VALLEY CURB TRANSITION FROM30" VALLEY GUTTER (TYP OF ALL) CURB TRANSITION FROM30" VALLEY GUTTER (TYP OF ALL) PROPOSED ADARAMP CROSSWALKWITH DETECTABLE WARNING DOME(TYP OF ALL) CURB TRANSITION FROM 30" VALLEY GUTTER(TYP OF ALL) 6" ABC TEMPORARYTURN-AROUND 10.0' LANDSCAPEEASEMENT (TYP) 30' LANDSCAPE EASEMENT 30.0' LANDSCAPEEASEMENT TEMPORARY ACCESS EASEMENT TEMPORARY ACCESSEASEMENT STREET LIGHT STREET LIGHT STREET LIGHT STREET LIGHT STREET LIGHT PROPOSED FIRE HYDRANT R50.0' R50.0' BOOKRANE LANE (PUBLIC & UTILITY R/W) 1. MAXIMUM PER LOT IMPERVIOUS SURFACE: 2,545 SF 2. SCM MAINTENANCE WILL BE THE RESPONSIBILITY OF THE HOA 3. OPEN SPACE: 3.44 ACRES (20.24%) 4. MAIL KIOSK, OPEN SPACE AND STREETSCAPE BUFFER TO BE MAINTAINED BY THE HOA 5. DRAINAGE EASEMENTS AND THE STORM WATER POND WILL BE MAINTAINED BY THEHOA 6. THE SIGN WILL BE PLACED AT LEAST 20' FROM THE INTERSECTION R/W'S AND ASEPARATE PERMIT WILL BE REQUIRED BEFORE CONSTRUCTION 7. A CERTIFIED FOUNDATION SURVEY, OR SETBACK VERIFICATION SURVEY, IS REQUIREDTO BE SUBMITTED AT THE COMPLETION OF FOUNDATION CONSTRUCTION 8. THIS DEVELOPMENT IS WITHIN ONE MILE OF A VOLUNTARY AGRICULTURAL DISTRICT 9. THIS DEVELOPMENT IS WITHIN THE FIVE MILE MILITARY CORRIDOR OVERLAY ZONE,AND MAY BE SUBJECT TO MILITARY TRAINING ACTIVITIES MAINTAIN 5' SEPARATION WALL TO WALL BETWEENWATER AND STORM DRAINAGE(TYP OF ALL) PROPOSED 6" PVC WATERLINE PROPOSED 6"PVC WATERLINE WATERLINE3.0' FROM BOC 5.0' FROM WALLTO WALLWITH STORM DRAINAGEAND WATERLINE 3.0' FROM BOC PROPOSEDFIRE HYDRANT STEPPING STONE LANE (PUBLIC & UTILITY R/W)BLACK FOREST DRIVE(PUBLIC & UTILITY R/W) 171TWO ADAMS, INCDEED BOOK 2202, PAGE 811PIN: 0524-69-2768.000PID: 010536 0105RCPOHU OHURUSSELL LYNN HAYESNO DEED FOUNDPIN: 0524-67-1662.000PID: 010524 0063 OHUHAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)OHURCPPHONE PEDESTAL OHU TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL DEED BOOK 684, PAGE 606 PIN: 0524-58-4260.000PID: 010534 0079 01 WATERVALVEOHU SSKRISTA HERNANDEZDEED BOOK 3971, PAGE 938 PLAT BOOK 2001, PAGE 833PIN: 0524-57-0707.000PID: 010524 0069 08 FEDERAL NATIONAL MORGAGEDEED BOOK 3882, PAGE 330PLAT BOOK 2002, PAGE 1445PIN: 0524-47-8778.000PID: 010524 0069 07 TWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03 TOM HUGH JOHNSONDEED BOOK 3945, PAGE 126 PLAT CABINET F, SLIDE 305-D PLAT CABINET 2, SLIDE 247 PLAT BOOK 98, PAGE 271 PIN: 0524-57-0707.000 PID: 010524 0069 08 169 168 1 6 8 167166 16 4 165166164 16 3 162 161 15 9 15 8 165160 16816 7 169168 167 16 6 16 4 163 162 16 1 16 5 160 168 167 16 6 164 163 162 16115 9 1 5 8 1 6 5 160 16 9 169 169168 16 7 1681 6 8168168168168169 169 16916916916916 9 169 169169169 168167169 168167 170169 168167169169169 168 167166 166167168169169169169 169 169 169 16917173170171170170172171172171172172171172170170170170170169 16917 0170170RCPRCPRCPRCP RCPRCP16" GRAVITY FEEDSANITARY SEWER EXISTING SOIL DRIVE EXISTING 40' UTILITY EASEMENT 20' EITHER SIDE OF CENTER OF UTILITIES - DETERMINED BY CLEARING LIMITS - IRON 3/4IRON 3/4 DELINATED WETLAND5,183 SF(ELEV = 158.1') EX NAIL IN PINE KNOT FOUND INWET AREA APPROXIMATE LOCATIONOF FEMA FLOOD ZONE ZONE AE BASE FLOOD ELEVETION = 158.9' EX. DRAINAGE CHANNEL >> EXISTING GRAVEL DRIVE EX 30' ACCESS EASEMENT PLAT BOOK 98, PG 271 CONC. MONUMENT EXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF 16" GRAVITY FEED SANITARY SEWER 16" GRAVITY FEED SANITARY SEWEREXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF UTILITY - DETERMINED BY CLEARING LIMITS - EX. SANITARYFORCE MAIN 30' SEWEREASEMENT 6" WATER LINE PER GISEX. DRAINAGE CHANNEL IRON 5/8" N:548092.95E:2025804.67 N:548128.77 E:2025101.13 RCPEX. OVERHEADPOWER LINE SSMH RIM = 168.60 INV = 147.66 SSMHRIM = 168.50INV = 148.06 SSMH RIM = 168.85 INV = 148.45 SSMH RIM = 168.08 INV = 148.98 SSMH RIM = 127.27INV = 149.22 SSMHRIM = 173.39INV = 149.29 SFO SFO SFO SFO SFO SFO SFO SFO SFOSFO SFO PROVIDE 1525LFOF SILT FENCE END 383LFOF SILT FENCE[DA=0.25 ACRESSILT FENCE NEEDED: 100 LF] CE TEMPORARY STOCKPILEAREA WITH SILT FENCE.MAINTAIN MINIMUM50' FROM SEDIMENT DEVICES SKIMMER DEWATERING DEVICE:SKIMMER SIZE: 4"ORIFICE SIZE: 3"DEWATERING TIME: 3.13 DAYS -SEE DETAIL POROUS COIRFIBER BAFFLE(3-EACH) LIMITS OF DISTURBANCE /PROPERTY LINE LIMITS OF DISTURBANCE CLCL CL CL CL CLCL OP 2'-2" X 3' PRECAST CONCRETERISER WITH TRASH RACK15" RCP STORM DRAIN PIPE OUTFLOW TO NATURAL LOW POINTINV OUT FROM RISER: 160.0'OUTLET PIPE TO BE C-443 WATERTIGHT JOINT RCP. SEDIMENT BASIN WITH BAFFLESBOTTOM LENGTH: 163.0'BOTTOM WIDTH: 79.5' (Average)TOP OF DAM ELEV: 167.50'BOTTOM OF BASIN ELEV: 156.0'SEDIMENT CLEANOUT ELEV: 162.5'BASIN SIDE SLOPES: 3:1 TO ELEV 162.0';6:1 TO ELEV. 161.0'; 3:1 TO ELEV 156.0'SEE POND DETAIL SHEET C-8.0. CONSTRUCTION OF OUTLETPIPE OF STORMWATER PONDTO BE COMPLETED BEFORECONSTRUCTION OF TEMPORARYSEDIMENT BASIN IS TO BE STARTED. PIPE INVERT = 159.0'RIPRAP VELOCITYDISSIPATOR3.75'W x 82.0 L x 17.25'W, CLASS B RIPRAP w/18" THICK FILTER FABRIC RIPRAP VELOCITYDISSIPATOR7.5'W x 18.0 L x 20.5'W, CLASS B RIPRAP w/18" THICK FILTER FABRIC CONSTRUCTIONSTAGING AREA. GRADE OUTFALLSWALE 3: 1 SLOPE MAX.IMMEDIATELY STABILIZEWITH PERMANENTGROUND COVER. SILT FENCE OUTLET(TYP.) BEGIN 862 LF OFSILT FENCE[DA = 1.37 ACRESSILT FENCE NEEDED 548 LF] BEGIN 383 LFOF SILT FENCT SB BF156 160158168167166165164163162156157 161160159158 168167166165164163162156161160158END 862 LF OFSILT FENCE BEGIN 1525 LF OFSILT FENCE END 1525LFOF SILT FENCE EROSION CONTROL PLAN -INITIAL PHASEC3.0 GENERAL NOTES: PURSUANT TO G.S. 133-A57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BENO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OROTHER ADEQUATE EROSION-CONTROL DEVICES OR STRUCTURES.IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 7 OR 14 CALENDAR DAYS OFCOMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDEDWITH TEMPORARY GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TORESTRAIN EROSION. PERMANENT GROUNDCOVER WILL BE PROVIDED FOR ALLDISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORE THAN 90 CALENDERDAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUNDCOVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBEDAREAS WITHIN 15 CALENDAR DAYS OR 60 CALENDAR DAYS (WHICHEVER IS SHORTER)FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. ANY BORROW MATERIAL BROUGHT ONTO THIS SITE MUST BE FROM A LEGALLYPERMITTED MINE SITE OR OTHER APPROVED SOURCE. A SINGLE-USE BORROW ORWASTE AREA SITE IS ONLY PERMISSIBLE IF IT IS OPERATED UNDER CONTROL OF THEFINANCIALLY RESPONSIBLE PERSON OR FIRM THAT IS DEVELOPING THIS SITE. ANAPPROVED EROSION AND SEDIMENT CONTROL PLAN IS REQUIRED FOR ALL SINGLEUSE BORROW AND WASTE SITES. EROSION CONTROL DESIGN, DETAILS AND MAINTENANCE SPECIFICATIONS SHALLCOMPLY WITH CURRENT NORTH CAROLINA EROSION AND SEDIMENT CONTROLPLANNING AND DESIGN MANUAL. SELF INSPECTION NOTE: THE LANDOWNER, THE FINANCIALLY RESPONSIBLE PARTY, OR THE LANDOWNER'SOR THE FINANCIALLY RESPONSIBLE PARTY'S AGENT SHALL PERFORM ANINSPECTION OF THE AREA COVERED BY THE PLAN AFTER EACH PHASE OF THE PLANHAS BEEN COMPLETED AND AFTER ESTABLISHMENT OF TEMPORARY GROUNDCOVER IN ACCORDANCE WITHG.S. 113A-57(2). THE PERSON WHO PERFORMS THE INSPECTION SHALL MAINTAINAND MAKE AVAILABLE A RECORD OF THE INSPECTION AT THE SITE OF THELAND-DISTURBING ACTIVITY. THE RECORD SHALL SET OUT ANY SIGNIFICANTDEVIATION FROM THE APPROVED EROSION CONTROL PLAN, IDENTIFY ANYMEASURES THAT MAY BE REQUIRED TO CORRECT THE DEVIATION, ANDDOCUMENT THE COMPLETION OF THOSE MEASURES. THE RECORD SHALL BEMAINTAINED UNTIL PERMANENT GROUND COVER HAS BEEN ESTABLISHED ASREQUIRED BY THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN. THEINSPECTIONS REQUIRED BY THIS SUBSECTION SHALL BE IN ADDITION TOINSPECTIONS REQUIRE BY G.S. 113A-61.1. SEE NCGO1 INSPECTION,RECORDKEEPING AND REPORTING PLAN SHEET. DESCRIPTIONPRACTICESYMBOL SILT FENCE A TEMPORARY STRUCTURE USED TO SLOW THE VELOCITY OF RUN-OFF,CAUSE SEDIMENT DEPOSITION AT THE STRUCTURE, AND FILTER SEDIMENT FROM RUN-OFF.SF CONSTRUCTION LIMITS A DEFINED AREA THAT ALL LAND DISTURBANCE WILL OCCUR DURING CONSTRUCTION.CL CONSTRUCTION ENTRANCE A STONE STABILIZED PAD LOCATED AT ANY POINT THAT TRAFFIC WILL BELEAVING A CONSTRUCTION SITE TO A PUBLIC RIGHT-OF-WAY, STREET, ALLEY, SIDEWALK, OR PARKING PLOT WHICH WILL REDUCE OR ELIMINATETHE TRANSPORT OF MUD FROM THE CONSTRUCTION SITE. CE PROTECTION A TEMPORARY STRUCTURE AS A REINFORCED OUTLET AT LOW POINTS OF THE SILT FENCE. INSTALL #57 WASHED STONE AT UPSTREAM FLOW WITHHARDWARE CLOTH. (SEE DETAIL)SFO SILT FENCE OUTLET DIVERSION A TEMPORARY RIDGE OR EXCAVATED CHANNEL OR COMBINATION RIDGEAND CHANNEL CONSTRUCTED ACROSS SLOPING LAND ON APREDETERMINED GRADE.TD TEMPORARY SB AN EARTHEN EMBANKMENT SUITABLY LOCATED TO CAPTURE RUNOFF,WITH A TRAPEZOIDAL SPILLWAY LINED WITH AN IMPERABLE GEOTEXTILEOR LAMINATED PLASTIC MEMBRANE, AND EQUIPPED WITH A FLOATING SKIMMER FOR DEWATERING. SEDIMENT BASIN BF POROUS BARRIERS INSTALLED INSIDE A TEMPORARY SEDIMENT TRAP,SKIMMER BASIN, OR SEDIMENT BASIN TO REDUCE THE VELOCITY AND TURBULENCE OF THE WATER FLOWING THROUGH THE MEASURE, AND TOFACILITATE THE SETTLING OF SEDIMENT FROM THE WATER BEFOREDISCHARGE. POROUS BAFFLE EROSION CONTROL MEASURE - INITIAL PHASE: 1. ENSURE ALL APPROVALS HAVE BEEN OBTAINED PRIOR TO ANY LAND DISTURBANCE. 2. CONDUCT ON-SITE PRE-CONSTRUCTION MEETING WITH THE CONTRACTOR, OWNER, ENGINEER AND CONSTRUCTION MANAGER TO REVIEW THE PROJECT AND EROSION CONTROL SEQUENCES. 3. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WITHIN AND IMMEDIATELY ADJACENT TO THE PROJECT AREA. 4. INSTALL CONSTRUCTION ENTRANCE AT LOCATION SHOWN ON THE PLAN - OFF OF EDGE OF EXISTING PAVEMENT ON HAYES ROAD. 5. FLAG LIMITS OF ALL DISTURBED AREA AS SHOWN ON THE PLANS FOR INSTALLATION OF PERIMETER EROSION CONTROL DEVICES - SILT FENCE AND SILT FENCE OUTLET AND SEDIMENT BASIN WHERE SHOWN ON THE PLANS. 6. INSTALL ALL SILT FENCE AND SEDIMENT BASINS AS SHOWN ON THE PLANS. 7. CONSTRUCT TEMPORARY DIVERSION DITCHES AS SHOWN ON THE PLANS. 8. “EROSION AND SEDIMENT CONTROL(E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF THE PLAN MUST BE KEPT ON SITE,PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION.” THE COC CAN BE OBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (E-NOI) FORM ATDEQ.NC.GOV/NCG01. PLEASE NOTE, THE E-NOI FORM MAY ONLY BE FILLED OUT ONCE THEPLANS HAVE BEEN APPROVED. 9. WITHIN 14 CALENDER DAYS OF COMPLETION OF ANY PHASE OF GRADING, GROUND COVER SHALL BE PROVIDED ON EXPOSED SLOPES AND PERMANENT GROUND COVER SHALL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 14 CALENDER DAYS OR 60 CALENDER DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 10. THE CONTRACTOR SHALL CONDUCT SELF-INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL MEASURES AND COMPLETE THE FOLLOWING COMBINED SELF-INSPECTION FORM FOUND ON THE DEMLR WEBSITE : https://files.nc.gov/ncdeq/Energy%20Mineral%20and%20Land%20Resources/Stormwater /NPDES%20General%20Permits/DEMLR-CSW-Monitoring-Form-Rev-August-8-2019.pdf TWELVE MONTHS OF COMPLETE INSPECTION FORMS SHALL BE KEPT ON-SITE AND AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. (GS 113A-54.1 (E), 15ANCAC 04B.0131, NCG01 PART III SECTIONS A AND B). 11. CLEAR AND GRUB SITE (WHERE REQUIRED) AND LEGALLY DISPOSE OF ALL DEBRIS OFF SITE. 12. “SELF-INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY NEEDED REPAIRS SHALL BE MADEIMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC MEASURES SHALL BE MAINTAINED AS SPECIFIED IN THE CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED AT THE PROJECT SITE FOR MONITORING. 13. TOTAL SITE DISTURBED AREA = 14.5 AC. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONNORTHBUDDYBAREFOOT RD2049 BETHEL BAPTIST RD2048 HAYES RD2047 BILLSHAW RD1144 SITE VICINITY MAPNOT TO SCALE REFERENCES: DEED BOOK 684, PAGE 606 PIN: 0524-87-7885.000 PID: 010534 0079 REID: 0023189 CURRENT OWNERS TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL 174 FARRAR ROAD LILLINGTON, NC 27546 NORTH0' SCALE IN FEET 30 60 120 CALCULATE SKIMMER SIZEBASIN VOLUME IN CUBIC FEET DAYS TO DRAIN* 26,298 3.13 Cu. Ft DAYS SKIMMER SIZE ORIFICE RADIUS ORIFICE DIAMETER 4.0 1.5 INCH INCHES 3.0 INCHES MAXIMUM HEIGHT OFFLOAT WHEN NO OTHERSTORM WATER DISCHARGEOPENINGS EXIST(MAJOR STORM EVENT) SCALE: N.T.S. 15" RCP OUTLETPIPE STORM WATERDISCHARGEOPENING EARTHENEMBANKMENT PVC VENT PIPE WATER ENTRYUNIT WITH TRASHSCREEN ORIFICE OPENING INSIDETHE HORIZONTAL TUBEWITH A CONSTANTHYDRAULIC HEAD FLOAT WATER ENTRY UNIT FLEXIBLEHOSE SCHEDULE 40 PVC PIPE(BARREL OR ARM) GENERAL NOTES:1. PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE.2. PROPER ORIFICE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OFTIME. MODIFICATIONS MAY BE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE.3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS.4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED.5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE DISCHARGE ENDOF THE PIPE.6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER.7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUT SHEET, ANDINSTRUCTIONS ON WEB SITE FOR EACH SIZE. TOP VIEW END VIEW SIDE VIEW L = 1.4 X DEPTHTO THE OVERFLOW MINIMUM LENGTHAPPLIES SEE POND CONTROLSTRUCTURE DETAILSHEET C-8.0 SCHEDULE 40 PVC PIPE(BARREL OR ARM) FLEXIBLE HOSE MUST BESECURELY FASTENED TO THEWATER QUALITY DISCHARGEOPENING OR TEMPORARYPLATE. SEE CONTROLSTRUCTURE DETAIL FLOAT PVC VENT PIPE ~ WET POND ~ FAIRCLOTH SKIMMER DISCHARGE SYSTEMWITH PERMANENT OUTLET STRUCTURE INV = 161.00' TOP OF RIM = 162.00' INV = 160.00' TWO ADAMS, INCDEED BOOK 2202, PAGE 811PIN: 0524-69-2768.000PID: 010536 0105RCPOHU OHURUSSELL LYNN HAYESNO DEED FOUNDPIN: 0524-67-1662.000PID: 010524 0063 OHUHAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)OHURCPPHONE PEDESTAL OHU TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL DEED BOOK 684, PAGE 606 PIN: 0524-58-4260.000PID: 010534 0079 01 WATERVALVEOHU SSKRISTA HERNANDEZDEED BOOK 3971, PAGE 938 PLAT BOOK 2001, PAGE 833PIN: 0524-57-0707.000PID: 010524 0069 08 FEDERAL NATIONAL MORGAGEDEED BOOK 3882, PAGE 330PLAT BOOK 2002, PAGE 1445PIN: 0524-47-8778.000PID: 010524 0069 07 TWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03 TOM HUGH JOHNSONDEED BOOK 3945, PAGE 126 PLAT CABINET F, SLIDE 305-D PLAT CABINET 2, SLIDE 247 PLAT BOOK 98, PAGE 271 PIN: 0524-57-0707.000 PID: 010524 0069 08 RCPRCPRCPRCP RCPRCP16" GRAVITY FEEDSANITARY SEWER EXISTING SOIL DRIVE EXISTING 40' UTILITY EASEMENT 20' EITHER SIDE OF CENTER OF UTILITIES - DETERMINED BY CLEARING LIMITS - IRON 3/4IRON 3/4 DELINATED WETLAND5,183 SF(ELEV = 158.1') EX NAIL IN PINE KNOT FOUND INWET AREA APPROXIMATE LOCATIONOF FEMA FLOOD ZONE ZONE AE BASE FLOOD ELEVETION = 158.9' EX. DRAINAGE CHANNEL >> EXISTING GRAVEL DRIVE EX 30' ACCESS EASEMENT PLAT BOOK 98, PG 271 CONC. MONUMENT EXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF 16" GRAVITY FEED SANITARY SEWER 16" GRAVITY FEED SANITARY SEWEREXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF UTILITY - DETERMINED BY CLEARING LIMITS - EX. SANITARYFORCE MAIN 30' SEWEREASEMENT 6" WATER LINE PER GISEX. DRAINAGE CHANNEL IRON 5/8" N:548092.95E:2025804.67 N:548128.77 E:2025101.13 RCPEX. OVERHEADPOWER LINE SSMH RIM = 168.60 INV = 147.66 SSMHRIM = 168.50INV = 148.06 SSMH RIM = 168.85 INV = 148.45 SSMH RIM = 168.08 INV = 148.98 SSMH RIM = 127.27INV = 149.22 SSMHRIM = 173.39INV = 149.29 W W W WWWWW W SSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SSWWWWWW W WWW156160158168167166165164163162156157 161160159158 167166165164163162156158168161SFO SFO SFO SFO SFO SFO SFO SFO SFOSFO SFO PROVIDE 1525LFOF SILT FENCE END 383LFOF SILT FENCE[DA=0.25 ACRESSILT FENCE NEEDED: 100 LF] CE TEMPORARY STOCKPILEAREA WITH SILT FENCE.MAINTAIN MINIMUM50' FROM SEDIMENT DEVICES SKIMMER DEWATERING DEVICE:SKIMMER SIZE: 4"ORIFICE SIZE: 3"DEWATERING TIME: 3.13 DAYS -SEE DETAIL POROUS COIRFIBER BAFFLE(3-EACH) LIMITS OF DISTURBANCE /PROPERTY LINE LIMITS OF DISTURBANCE CLCL CL CL CL CLCL IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP CWA OP TD 2'-2" X 3' PRECAST CONCRETERISER WITH TRASH RACK15" RCP STORM DRAIN PIPE OUTFLOW TO NATURAL LOW POINTINV OUT FROM RISER: 160.0'OUTLET PIPE TO BE C-443 WATERTIGHT JOINT RCP. SEDIMENT BASIN WITH BAFFLESBOTTOM LENGTH: 163.0'BOTTOM WIDTH: 79.5' (Average)TOP OF DAM ELEV: 167.50'BOTTOM OF BASIN ELEV: 156.0'SEDIMENT CLEANOUT ELEV: 162.5'BASIN SIDE SLOPES: 3:1 TO ELEV 162.0';6:1 TO ELEV. 161.0'; 3:1 TO ELEV 156.0'SEE POND DETAIL SHEET C-8.0. CONSTRUCTION OF OUTLETPIPE OF STORMWATER PONDTO BE COMPLETED BEFORECONSTRUCTION OF TEMPORARYSEDIMENT BASIN IS TO BE STARTED. PIPE INVERT = 159.0'RIPRAP VELOCITYDISSIPATOR3.75'W x 82.0 L x 17.25'W, CLASS B RIPRAP w/18" THICK FILTER FABRIC GRADE TO CONFINE DISCHARGETOWARD EXISTING WETLAND3: 1 SLOPE MAX. STABILIZESLOPE IMMEDIATELY WITHSODDING. RIPRAP VELOCITYDISSIPATOR7.5'W x 18.0 L x 20.5'W, CLASS B RIPRAP w/18" THICK FILTER FABRIC CONSTRUCTIONSTAGING AREA. GRADE OUTFALLSWALE 3: 1 SLOPE MAX.IMMEDIATELY STABILIZEWITH PERMANENTGROUND COVER. SILT FENCE OUTLET(TYP.) IPIP CONCRETEWASHOUTAREA IP IP IP IP BEGIN 862 LF OFSILT FENCE[DA = 1.37 ACRESSILT FENCE NEEDED 548 LF] BEGIN 383 LFOF SILT FENCT PERMANENT DIVERSION SWALE WITH BERM:BERM HEIGHT: 0.76'TOTAL DEPTH FROM TOP OF BERMTO DITCH BOTTOM: 1.5'TOP OF BERM WIDTH: 2.0'BOTTOM OF BERM WIDTH: 6.0'SIDE SLOPE: 3:1LINING: SEED AND MULCH WITHCONTRACTOR'S BLEND SB BF IP 156160158168167166165164163162156157 161160159158 168167166165164163162156161160158IP END 862 LF OFSILT FENCE BEGIN 1525 LF OFSILT FENCE END 1525LFOF SILT FENCE EROSION CONTROL PLAN -CONSTRUCTION PHASEC3.1 TEMPORARY FACILITY PROVIDED ONSITE FOR CONCRETE TRUCKS TOWASHOUT PRIOR TO LEAVING CONSTRUCTION SITE, CONTRACTOR MAYRELOCATE ONSITE AS DEEMED NECESSARY THROUGH-OUT CONSTRUCTION CWA CONCRETE WASHOUTAREA DESCRIPTIONPRACTICESYMBOL INLET PROTECTION A TEMPORARY SEDIMENT BARRIER LAID AROUND A STORM DRAIN INLETTO PREVENT SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM.IP ALL OTHER AREASWITH SLOPESFLATTER THAN 4:1 SLOPES 3:1 ORFLATTER 14 DAYS SLOPES STEEPERTHAN 3:1 14 DAYS 7 DAYS HIGH QUALITY WATER(HQW) ZONESFLATTER THAN 4:1 7 DAYS PERIMETER DIKES, SWALES, DITCHES ANDSLOPES 7 DAYS TYPICAL GROUND COVER STABILIZATION TYPES - GRASSAND OR SOD, WHEAT STRAW, MULCH, BIODEGRADABLESTRAW MATTING, SYNTHETIC MATTING, ETC. NONE NONE NONE(EXCEPT FOR PERIMETERAND HQW ZONES) IF SLOPES ARE 10' OR LESSIN LENGTH AND ARE NOTSTEEPER THAN 2:1 14 DAYSARE ALLOWED 7 DAYS FOR SLOPES GREATERTHAN 50 FEET IN LENGTH SITE AREADESCRIPTION STABILIZATIONTIME FRAME STABILIZATION TIMEFRAME EXCEPTIONS CONTRACTOR SHALL BE REQUIRED TO ESTABLISH GROUNDSTABILIZATION AS PER FOLLOWING CHART. GROUND STABILIZATION REQUIREMENTS APPLICABLETHIS PROJECT YES NO NO YES YES BASIN REMOVAL SEQUENCE: 1. SCHEDULE A SITE MEETING WITH THE ENVIRONMENTAL ENGINEER/CONSULTANT TODETERMINE IF THE BASIN CAN BE REMOVED. INSTALL SILT FENCING AND EXTEND TOPROPERTY CORNER. 2. REMOVE BASIN AND ASSOCIATED TEMPORARY DIVERSION DITCHES. FINE GRADEAREAS IN PREPARATION FOR SEEDING. 3. PERFORM SEEDBED PREPARATION, SEED, MULCH AND ASPHALT TACH ANDRESULTING BARE AREA IMMEDIATELY. 4. WHEN SITE IS FULLY STABILIZED, CALL NCDEQ FOR APPROVAL OF REMOVINGREMAINING TEMPORARY EROSION CONTROL MEASURES AND ADVICE ON WHEN SITECAN BE ISSUES A CERITIFICATE OF COMPLETION. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONNORTHBUDDYBAREFOOT RD2049 BETHEL BAPTIST RD2048 HAYES RD2047 BILLSHAW RD1144 SITE VICINITY MAPNOT TO SCALE NORTH0' SCALE IN FEET 30 60 120 CONSTRUCTION SEQUENCE & EROSION CONTROLMEASURES - CONSTRUCTION PHASE: 1. CHECK ALL SILT FENCE AND REPAIR AS NECESSARY. ASSURE ANY ERODED AREAARE STABILIZED WITH TEMPORARY SEEDING AND MULCH. 2. ROUGH GRADE ROADWAY RIGHT OF WAY AREA. 3. INSTALL THE SEWER AND WATER SYSTEMS AS SHOWN ON THE PLANS. 4. INSTALL STORM DRAINAGE SYSTEMS. 5. INSTALL INLET / OUTLET BMP'S WHERE REQUIRED. 6. GRADE AND PREPARE SUBGRADE FOR PAVEMENT AREA. 7. PLACE COMPACTED G.A.B.C FOR ASPHALT CONSTRUCTION. 8. FINISH FINE GRADING THE ROAD RIGHT OF WAYS AND COMMON AREAS. 9. COMPLETE ALL REMAINING SITE IMPROVEMENTS. 10. PLACE ASPHALT, PAVEMENT MARKINGS, AND SIGNAGE. REFERENCES: DEED BOOK 684, PAGE 606 PIN: 0524-87-7885.000 PID: 010534 0079 REID: 0023189 CURRENT OWNERS TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL 174 FARRAR ROAD LILLINGTON, NC 27546 TWO ADAMS, INCDEED BOOK 2202, PAGE 811PIN: 0524-69-2768.000PID: 010536 0105RCPOHU OHURUSSELL LYNN HAYESNO DEED FOUNDPIN: 0524-67-1662.000PID: 010524 0063 OHUHAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)OHURCPPHONE PEDESTAL OHU TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL DEED BOOK 684, PAGE 606 PIN: 0524-58-4260.000PID: 010534 0079 01 WATERVALVEOHU SSKRISTA HERNANDEZDEED BOOK 3971, PAGE 938 PLAT BOOK 2001, PAGE 833PIN: 0524-57-0707.000PID: 010524 0069 08 FEDERAL NATIONAL MORGAGEDEED BOOK 3882, PAGE 330PLAT BOOK 2002, PAGE 1445PIN: 0524-47-8778.000PID: 010524 0069 07 TWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03 TOM HUGH JOHNSONDEED BOOK 3945, PAGE 126 PLAT CABINET F, SLIDE 305-D PLAT CABINET 2, SLIDE 247 PLAT BOOK 98, PAGE 271 PIN: 0524-57-0707.000 PID: 010524 0069 08 RCPRCPRCPRCP RCPRCP16" GRAVITY FEEDSANITARY SEWER EXISTING SOIL DRIVE EXISTING 40' UTILITY EASEMENT 20' EITHER SIDE OF CENTER OF UTILITIES - DETERMINED BY CLEARING LIMITS - IRON 3/4IRON 3/4 DELINATED WETLAND5,183 SF(ELEV = 158.1') EX NAIL IN PINE KNOT FOUND INWET AREA APPROXIMATE LOCATIONOF FEMA FLOOD ZONE ZONE AE BASE FLOOD ELEVETION = 158.9' EX. DRAINAGE CHANNEL >> EXISTING GRAVEL DRIVE EX 30' ACCESS EASEMENT PLAT BOOK 98, PG 271 CONC. MONUMENT EXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF 16" GRAVITY FEED SANITARY SEWER 16" GRAVITY FEED SANITARY SEWEREXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF UTILITY - DETERMINED BY CLEARING LIMITS - EX. SANITARYFORCE MAIN 30' SEWEREASEMENT 6" WATER LINE PER GISEX. DRAINAGE CHANNEL IRON 5/8" N:548092.95E:2025804.67 N:548128.77 E:2025101.13 RCPEX. OVERHEADPOWER LINE SSMH RIM = 168.60 INV = 147.66 SSMHRIM = 168.50INV = 148.06 SSMH RIM = 168.85 INV = 148.45 SSMH RIM = 168.08 INV = 148.98 SSMH RIM = 127.27INV = 149.22 SSMHRIM = 173.39INV = 149.29 W W W WWWWW W SSSSSSSSSSSSSSSS1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 31 30 29282726252423 SS SS SS SS SS SS SS SS SS21 33 32 20 22 34 35 36 WWWWWW W WWW156160158168167166165164163162156157 161160159158 167166165164163162156158168161PERMANENT SWALE WITHBERM TO BE CLEANED OUTAND STABILIZED SKIMMER REMOVAL NOTE:UPON COMPLETION AND STABILIZATIONOF UPSTREAM AREAS, CLEANOUT ALL SEDIMENTFROM THE BASIN AND EXCAVATE BOTTOM TO 160.0'.CONSTRUCT PERMANENT FOREBAY AS SHOWN.CONSTRUCT PERMANENT RISER BARREL. SEE DETAIL.Ds3Ds3Ds3Ds3Ds3Ds3Ds3Ds3Ds3Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 Ds3 156160158168167166165164163162156157 161160159158 168167166165164163162156161160158REMOVE BAFFLED AND CONSTRUCTFOREBAY WITH GABION BASKETS.SEE WET POND DETAIL EROSION CONTROL PLAN -FINAL PHASEC3.2 Ds3 (LBS.) MARCH 15TOSEPT. 12175(UNHULLED)COMMON BERMUDA AUG. 31TOMARCH 161 140TALL FESCUE 210 PERMANENT VEGETATIONSEEDING SCHEDULE FOR DATESPLANTINGRATE PER ACRE (HULLED)COMMON BERMUDA OF SEEDCOMMON NAMENO.SCHEDULE NOTES: GIANT BERMUDA SEED, INCLUDING NK-37, SHALL NOT BE USED. THE CONTRACTOR SHALL OBTAIN A SATISFACTORY STAND OFPERENNIAL VEGETATION WHOSE ROOT SYSTEM SHALL BE DEVELOPEDSUFFICIENTLY TO SURVIVE DRY PERIODS AND WINTER WEATHER, ANDBE CAPABLE OF RE-ESTABLISHMENT IN THE SPRING. THE PERENNIAL VEGETATIVE COVER SHALL HAVE A MINIMUM COVERAGE DENSITY OF 70% FOR THE SEEDED AREAS. CONTRACTOR SHALL DETERMINE ALL RATES OF APPLICATION NECESSARY TO PRODUCE THE REQUIREDSTAND OF GRASS, AND SHALL FOLLOW THE APPLICATIONPROCEDURES AS SPECIFIED HEREIN. DESCRIPTIONPRACTICESYMBOL ALL OTHER AREASWITH SLOPESFLATTER THAN 4:1 SLOPES 3:1 ORFLATTER 14 DAYS SLOPES STEEPERTHAN 3:1 14 DAYS 7 DAYS HIGH QUALITY WATER(HQW) ZONESFLATTER THAN 4:1 7 DAYS PERIMETER DIKES, SWALES, DITCHES ANDSLOPES 7 DAYS TYPICAL GROUND COVER STABILIZATION TYPES - GRASSAND OR SOD, WHEAT STRAW, MULCH, BIODEGRADABLESTRAW MATTING, SYNTHETIC MATTING, ETC. NONE NONE NONE(EXCEPT FOR PERIMETERAND HQW ZONES) IF SLOPES ARE 10' OR LESSIN LENGTH AND ARE NOTSTEEPER THAN 2:1 14 DAYSARE ALLOWED 7 DAYS FOR SLOPES GREATERTHAN 50 FEET IN LENGTH SITE AREADESCRIPTION STABILIZATIONTIME FRAME STABILIZATION TIMEFRAME EXCEPTIONS CONTRACTOR SHALL BE REQUIRED TO ESTABLISH GROUNDSTABILIZATION AS PER FOLLOWING CHART. GROUND STABILIZATION REQUIREMENTS APPLICABLETHIS PROJECT YES NO NO YES YES CONSTRUCTION LIMITS A DEFINED AREA THAT ALL LAND DISTURBANCE WILL OCCURDURING CONSTRUCTION.CL CONSTRUCTION SEQUENCE & EROSION CONTROLMEASURES - FINAL PHASE: 1. UPON COMPLETING ALL SITE IMPROVEMENTS AND FINAL GRADING, STABILIZE ALL DISTURBED AREASPER LANDSCAPE PLAN. WATER AND MAINTAIN ALL LANDSCAPED AREAS TO ENSURE PROPER GROUNDCOVERAGE PRIOR TO FINAL APPROVAL 2. PERIMETER MEASURES, SILT FENCE AND TEMPORARY DIVERSION MUST BE LEFT INPLACE UNTIL ALLUPLAND AREAS ARE STABILIZED WITH PERMANENT VEGETATION. 3.SEE SEEDING SCHEDULE PROVIDED IN EROSION CONTROL DETAIL. 4. AFTER SITE IS PERMANENTLY STABILIZED,REMOVE ALL TEMPORARY EROSION CONTROL MEASURESAND PROVIDE PERMANENT SEEDING WHERE TEMPORARY MEASURES HAVE BEEN REMOVED ANDGROUND COVER IS NOT ADEQUATE. SEDIMENT BASINS MAY NOT BE REMOVED OR CONVERTED TOPERMANENT BMPS UNTIL ALL UPLAND AREAS ARE PERMANENTLY STABILIZED. (GS 113A-57(3). 15A NCAC04B. 0113) 5. WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SCPLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT,THE PERMITTEE SHALL VISIT DEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION(e-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE e-NOT HAS BEEN FILLEDOUT. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONNORTHBUDDYBAREFOOT RD2049 BETHEL BAPTIST RD2048 HAYES RD2047 BILLSHAW RD1144 SITE VICINITY MAPNOT TO SCALE NORTH0' SCALE IN FEET 30 60 120 REFERENCES: DEED BOOK 684, PAGE 606 PIN: 0524-87-7885.000 PID: 010534 0079 REID: 0023189 CURRENT OWNERS TOMMY LYNN MCPHAIL AND WIFE, BONNIE H. MCPHAIL 174 FARRAR ROAD LILLINGTON, NC 27546 NOTE: PURSUANT TO G.S. 133-A57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION-CONTROL DEVICES OR STRUCTURES.IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 7 OR 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PERMANENT GROUNDCOVER WILL BE PROVIDED FORALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORE THAN 90 CALENDER DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUNDCOVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 CALENDAR DAYS OR 60 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. NOTE: EFFECTIVE OCTOBER1, 2010, PERSONS CONDUCTING LAND-DISTURBING ACTIVITIES LARGER THANONE ACRE MUST INSPECT THEIR PROJECT AFTER EACH PHASE OF THE PROJECT AND DOCUMENT THE INSPECTION IN WRITING. KEEP WRITTEN INSPECTION REPORTS ON CONSTRUCTION SITE IN WHICH IT SHOULD BE READILY AVAILABLE FOR EROSION CONTROL INSPECTOR'S REVIEW WHEN VISITING SITE. SELF-INSPECTION REPORT FORMS ARE AVAILABLE AS AN EXCEL SPREADSHEET FROM LAND QUALITY WEB SITE: www.dlr.enr.state.nc.us/pages/sedimentation_new.html LAND GRADING: PERIODICALLY CHECK ALL GRADED AREAS AND THE SUPPORTING EROSION AND SEDIMENTATION CONTROL PRACTICES, ESPECIALLY AFTER HEAVY RAINFALLS. PROMPTLY REMOVE ALL SEDIMENT FROM DIVERSIONS AND OTHER WATER-DISPOSAL PRACTICES. IF WASHOUT OR BREAKS OCCUR, REPAIR THEM IMMEDIATELY. PROMPT MAINTENANCE OF SMALL ERODED AREAS BEFORE THEY BECOME SIGNIFICANT GULLIES IS AN ESSENTIAL PART OF AN EFFECTIVE EROSION AND SEDIMENTATION CONTROL PLAN. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. OUTLET STABILIZATION STRUCTURE: INSPECT RIP RAP OUTLET STRUCTURES AFTER HEAVY RAINS TO SEE IF ANY EROSION AROUND OR BELOW THE RIP RAP HAS TAKEN PLACE OR IF STONES HAVE BEENDISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. DROP INLET PROTECTION (TEMPORARY): INSPECT THE FABRIC BARRIER AFTER EACH RAIN AND MAKE REPAIRS AS NEEDED. REMOVE SEDIMENT FROM THE POOL AREA AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE FABRIC DURING SEDIMENT REMOVAL. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN ADEQUATELY STABILIZED, REMOVE ALL MATERIALS AND ANY UNSTABLE SEDIMENT AND DISPOSE OF THEM PROPERLY. BRING THE DISTURBED AREA TO THE GRADE OF THE DROP INLET AND SMOOTH AND COMPACT IT. APPROPRIATELY STABILIZE ALL BARE AREAS AROUND THE INLET. SEDIMENT FENCE (SILT FENCE): INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. DUST CONTROL: MAINTAIN DUST CONTROL MEASURES THROUGH DRY WEATHER PERIODS UNTIL ALL DISTURBED AREAS HAVE BEEN STABILIZED. TREE PRESERVATION AND PROTECTION: REPAIR ANY DAMAGE TO PROTECTED TREE AS FOLLOW SHOULD DAMAGE TO CROWN, TRUNK, OR ROOT SYSTEM OCCUR. (REFERENCE NCDENR MANUAL, PAGE 6.05.3 AND 6.05.4) REPAIR ROOTS BY CUTTING OFF THE DAMAGED AREAS AND PAINTING THEM WITH TREE PAINT.SPREAD PEAT MOSS OR MOIST TOPSOIL OVER EXPOSED ROOTS. REPAIR DAMAGE TO BARK BY TRIMMING AROUND THE DAMAGED AREAS AS SHOWN IN FIGURE 6.05b, TAPER THE CUT TO PROVIDE DRAINAGE, AND PAINT WITH TREE PAINT. CUT OFF ALL DAMAGED TREE LIMBS ABOVE THE TREE COLLAR AT THE TRUNK OR MAIN BRANCH. USE THREE SEPARATED CUTS AS SHOWN IN FIGURE 6.05c TO AVOID PEELING BARK FROM HEALTHY AREAS OF THE TREE. EROSION CONTROL MAINTENANCE SCHEDULE EROSION CONTROL NARRATIVEC3.3 120 200120 GERMAN MILLET SPECIES WINTER RYE (GRAIN) SPECIES KOBE LESPEDEZA SEEDING SCHEDULE NOTE OF BERMUDA OR SERICEA LESPEDEZA PER ONE SQUARE FOOT. TEMPORARY SUMMER SEED MIX MARCH 1 - SEPT. 1 SEPT. 1 - MARCH 1 TEMPORARY WINTER SEED MIX 60 30 25 SPECIES SERICEA LESPEDEZA COMMON BERMUDAPENSICOLA BAHIAGRASS SPECIES 1030KOBE LESPEDEZASERICEA LESPEDEZA (UNSCARIFIED) COMMON BERMUDA 30 * MULCH WATER REQUIRED FOR PERMANENT SEED MIX ONLY APPLY SUPERPHOSPHATE (0-49-0) AT A RATE OF 200 LB/ACRE APPLY FERTILIZER (10-10-10) AT A RATE OF 1000 LB/ACRE APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER. MAINTENANCE OF 400 GAL./ACRE MARCH 1 - JULY 1 SEPT. 1 - NOV. 1 PERMANENT FALL SEED MIX SOIL AMENDMENTS PERMANENT SPRING SEED MIX BE CHECKED FOR ADEQUACY ON JULY 15. AN ADEQUATE COVER SHALL HAVE 50 SPRIGSCALENDAR DAYS AND SUBJECT TO FURTHER DISTURBANCE. PERMANENT SEED MIX SHALLTEMPORARY SEED MIX SHALL BE USED FOR ALL AREAS EXPOSED GREATER THAN 21 MINIMUM OF 1" OF RAINFALL A WEEK (IF NOT SUPPLIED NATURALLY, CONTRACTOR APPLY LIME (GROUND AGRICULTURAL LIMESTONE) AT A RATE OF 4000 LB/ACRE SHALL SUPPLY THE REMAINING AMOUNT UNTIL GROUND COVER HAS BEEN ESTABLISHED). TO BE INCORPORATED INTO THE TOP 3 INCHES OF SOIL IN AREAS WITH SLOPES 2:1 OR FLATTER ANCHOR MULCH WITH ROVING, NETTING OR BY TACKING WITH ASPHALT EMULSION AT A RATE (TO BE FOLLOWED BY PERMANENT FALL SEED MIX) RATE (LB./ACRE) RATE (LB./ACRE) (TO BE FOLLOWED BY PERMANENT SPRING SEED MIX) RATE (LB./ACRE) RATE (LB./ACRE) MOW WHEN THE AVERAGE PLANT HEIGHT EXCEEDS 6 INCHES.RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. REFERTILIZE IN THE SECOND YEAR UNLESS THE GROWTH IS FULLY ADEQUATE. ALL OTHER AREASWITH SLOPESFLATTER THAN 4:1 SLOPES 3:1 ORFLATTER 14 DAYS SLOPES STEEPERTHAN 3:1 14 DAYS 7 DAYS HIGH QUALITY WATER(HQW) ZONESFLATTER THAN 4:1 7 DAYS PERIMETER DIKES, SWALES, DITCHES ANDSLOPES 7 DAYS TYPICAL GROUND COVER STABILIZATION TYPES - GRASSAND OR SOD, WHEAT STRAW, MULCH, BIODEGRADABLESTRAW MATTING, SYNTHETIC MATTING, ETC. NONE NONE NONE(EXCEPT FOR PERIMETERAND HQW ZONES) IF SLOPES ARE 10' OR LESSIN LENGTH AND ARE NOTSTEEPER THAN 2:1 14 DAYSARE ALLOWED 7 DAYS FOR SLOPES GREATERTHAN 50 FEET IN LENGTH SITE AREADESCRIPTION STABILIZATIONTIME FRAME STABILIZATION TIMEFRAME EXCEPTIONS CONTRACTOR SHALL BE REQUIRED TO ESTABLISH GROUNDSTABILIZATION AS PER FOLLOWING CHART. GROUND STABILIZATION REQUIREMENTS APPLICABLETHIS PROJECT YES NO NO YES YES SEED BED PREPARATION APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE IN ACCORDANCE REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE MULCH IN ACCORDANCE WITH "SEEDING SCHEDULE" IMMEDIATELY AFTER SEEDING. INSPECT ALL SEEDING FOR COMPLIANCE WITH THE REQUIREMENTS OF THE "SEEDINGSCHEDULE". MAKE NECESSARY REPAIRS AND RESEED WITHIN THE PLANTING SEASON,IF POSSIBLE, OR THE DAMAGED AREA SHALL BE REESTABLISHED FOLLOWING THE ORIGINAL SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDINGEQUIPMENT OR CULTIPACK AFTER SEEDING. SEED ACCORDING TO "SEEDING SCHEDULE." CONTINUE TILLAGE UNTIL A WELL-PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED RIP THE ENTIRE AREA TO 6" DEPTH. REASONABLY SMOOTH AND UNIFORM. WITH "SEEDING SCHEDULE" AND MIX WITH SOIL. IS PREPARED 4 TO 6 INCHES DEEP. LIME, FERTILIZER, AND SEEDING REQUIREMENTS. 7. 2. 4. 5. 6. 3. 1. NATURE AND PURPOSE OF CONSTRUCTION THE PURPOSE OF THIS PROJECT IS TO PROVIDE ROAD ACCESS FOR RESIDENTIAL DEVELOPMENTSITE. THE PROJECT WILL INVOLVE CONSTRUCTION OF CONVEYANCE SWALE FOR STORMWATER DISCHARGE , SANITARY SEWER, WATER MAIN CONNECTION, STORM DRAINAGE SYSTEM AS WELL AS SANITARY AND WATER SERVICE LINES. THE SITE WILL BE PREPARED FOR INDIVIDUAL RESIDENTIALHOME CONSTRUCTION ON EACH LOT. PERMANENT VEGETATION SHALL BE ESTABLISHED QUICKLY UPON COMPLETION OF THE ROADWAYGRADING AND INFRASTRUCTURES IN ORDER TO REDUCE THE AMOUNT OF SEDIMENT RUNOFF FROM THE SITE. SITE IS NOT IN FLOOD PLAIN. WETLANDS AREA SHOWN ON THESE PLANS IN THE NORTHWEST CORNER OF THE PROPERTY. EROSION CONTROL MEASURE - INITIAL PHASE: 1. ENSURE ALL APPROVALS HAVE BEEN OBTAINED PRIOR TO ANY LAND DISTURBANCE. 2. CONDUCT ON-SITE PRE-CONSTRUCTION MEETING WITH THE CONTRACTOR, OWNER, ENGINEER ANDCONSTRUCTION MANAGER TO REVIEW THE PROJECT AND EROSION CONTROL SEQUENCES. 3. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WITHIN AND IMMEDIATELY ADJACENT TO THE PROJECT AREA. 4. INSTALL CONSTRUCTION ENTRANCE AT LOCATION SHOWN ON THE PLAN - OFF OF EDGE OF EXISTING PAVEMENTON HAYES ROAD. 5. FLAG LIMITS OF ALL DISTURBED AREA AS SHOWN ON THE PLANS FOR INSTALLATION OF PERIMETER EROSIONCONTROL DEVICES - SILT FENCE AND SILT FENCE OUTLET AND SEDIMENT BASIN WHERE SHOWN ON THE PLANS. 6. INSTALL ALL SILT FENCE AND SEDIMENT BASINS AS SHOWN ON THE PLANS. 7. CONSTRUCT TEMPORARY DIVERSION DITCHES AS SHOWN ON THE PLANS. 8. “EROSION AND SEDIMENT CONTROL(E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINEDBEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OFTHE PLAN MUST BE KEPT ON SITE, PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION.” THECOC CAN BE OBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (E-NOI) FORM ATDEQ.NC.GOV/NCG01.PLEASE NOTE, THE E-NOI FORM MAY ONLY BE FILLED OUT ONCE THE PLANS HAVE BEEN APPROVED. 9. WITHIN 14 CALENDER DAYS OF COMPLETION OF ANY PHASE OF GRADING, GROUND COVER SHALL BE PROVIDEDON EXPOSED SLOPES AND PERMANENT GROUND COVER SHALL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN14 CALENDER DAYS OR 60 CALENDER DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OFCONSTRUCTION OR DEVELOPMENT. 10. THE CONTRACTOR SHALL CONDUCT SELF-INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROLMEASURES AND COMPLETE THE FOLLOWING COMBINED SELF-INSPECTION FORM FOUND ON THE DEMLR WEBSITE:https://files.nc.gov/ncdeq/Energy%20Mineral%20and%20Land%20Resources/Stormwater/NPDES%20General%20Permits/DEMLR-CSW-Monitoring-Form-Rev-August-8-2019.pdfTWELVE MONTHS OF COMPLETE INSPECTION FORMS SHALL BE KEPT ON-SITE AND AVAILABLE FOR INSPECTIONAT ALL TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. (GS 113A-54.1 (E), 15ANCAC 04B.0131,NCG01 PART III SECTIONS A AND B). 11. CLEAR AND GRUB SITE (WHERE REQUIRED) AND LEGALLY DISPOSE OF ALL DEBRIS OFF SITE. 12. “SELF-INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEASTONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH.ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC MEASURESSHALL BE MAINTAINED AS SPECIFIED IN THE CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BEINSTALLED AT THE PROJECT SITE FOR MONITORING. 13. TOTAL SITE DISTURBED AREA = 14.5 AC. BASIN REMOVAL SEQUENCE: 1. SCHEDULE A SITE MEETING WITH THE ENVIRONMENTALENGINEER/CONSULTANT TO DETERMINE IF THE BASIN CAN BEREMOVED. INSTALL SILT FENCING AND EXTEND TO PROPERTYCORNER. 2. REMOVE BASIN AND ASSOCIATED TEMPORARY DIVERSIONDITCHES. FINE GRADE AREAS IN PREPARATION FOR SEEDING. 3. PERFORM SEEDBED PREPARATION, SEED, MULCH ANDASPHALT TACH AND RESULTING BARE AREA IMMEDIATELY. 4. WHEN SITE IS FULLY STABILIZED, CALL NCDEQ FOR APPROVALOF REMOVING REMAINING TEMPORARY EROSION CONTROLMEASURES AND ADVICE ON WHEN SITE CAN BE ISSUES ACERITIFICATE OF COMPLETION. CONSTRUCTION SEQUENCE & EROSIONCONTROL MEASURES - CONSTRUCTION PHASE: 1. CHECK ALL SILT FENCE AND REPAIR AS NECESSARY. ASSURE ANYERODED AREA ARE STABILIZED WITH TEMPORARY SEEDING ANDMULCH. 2. ROUGH GRADE ROADWAY RIGHT OF WAY AREA. 3. INSTALL THE SEWER AND WATER SYSTEMS AS SHOWN ON THEPLANS. 4. INSTALL STORM DRAINAGE SYSTEMS. 5. INSTALL INLET / OUTLET BMP'S WHERE REQUIRED. 6. GRADE AND PREPARE SUBGRADE FOR PAVEMENT AREA. 7. PLACE COMPACTED G.A.B.C FOR ASPHALT CONSTRUCTION. 8. FINISH FINE GRADING THE ROAD RIGHT OF WAYS AND COMMONAREAS. 9. COMPLETE ALL REMAINING SITE IMPROVEMENTS. 10. PLACE ASPHALT, PAVEMENT MARKINGS, AND SIGNAGE. CONSTRUCTION SEQUENCE &EROSION CONTROL MEASURES - FINALPHASE: 1. UPON COMPLETING ALL SITE IMPROVEMENTS AND FINAL GRADING,STABILIZE ALL DISTURBED AREAS PER LANDSCAPE PLAN. WATER ANDMAINTAIN ALL LANDSCAPED AREAS TO ENSURE PROPER GROUNDCOVERAGE PRIOR TO FINAL APPROVAL 2. PERIMETER MEASURES, SILT FENCE AND TEMPORARY DIVERSIONMUST BE LEFT INPLACE UNTIL ALL UPLAND AREAS ARE STABILIZEDWITH PERMANENT VEGETATION. 3.SEE SEEDING SCHEDULE PROVIDED IN EROSION CONTROL DETAIL. 4. AFTER SITE IS PERMANENTLY STABILIZED,REMOVE ALL TEMPORARYEROSION CONTROL MEASURES AND PROVIDE PERMANENT SEEDINGWHERE TEMPORARY MEASURES HAVE BEEN REMOVED AND GROUNDCOVER IS NOT ADEQUATE. SEDIMENT BASINS MAY NOT BE REMOVEDOR CONVERTED TO PERMANENT BMPS UNTIL ALL UPLAND AREAS AREPERMANENTLY STABILIZED. (GS 113A-57(3). 15A NCAC 04B. 0113) 5. WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACTDEMLR TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THEPERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THEPERMITTEE SHALL VISIT DEQ.NC.GOV/NCG01 TO SUBMIT ANELECTRONIC NOTICE OF TERMINATION (e-NOT). A $100 ANNUALGENERAL PERMIT FEE WILL BE CHARGED UNTIL THE e-NOT HAS BEENFILLED OUT. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION EROSION CONTROL GROUND STABILIZATIONAND SELF INSPECTION NOTESC3.4 NCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITHTHE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the constructionactivity being considered compliant with the Ground Stabilization and Materials Handlingsections of the NCG01 Construction General Permit (Sections E and F, respectively). Thepermittee shall comply with the Erosion and Sediment Control plan approved by thedelegated authority having jurisdiction. All details and specifications shown on this sheetmay not apply depending on site conditions and the delegated authority having jurisdiction. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of thetechniques in the table below: POLYACRYLAMIDES (PAMS) AND FLOCCULANTS1. Select flocculants that are appropriate for the soils being exposed duringconstruction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of ApprovedPAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before dischargingoffsite. 5. Store flocculants in leak-proof containers that are kept under storm-resistant coveror surrounded by secondary containment structures. HAZARDOUS AND TOXIC WASTE1. Create designated hazardous waste collection areas on-site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. EQUIPMENT AND VEHICLE MAINTENANCE1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from theproject.4. Collect all spent fluids, store in separate containers and properly dispose ashazardous waste (recycle when possible).5. Remove leaking vehicles and construction equipment from service until the problemhas been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum productsto a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trashreceptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surfacewaters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runofffrom upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events orprovide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds.7. Empty waste containers as needed to prevent overflow. Clean up immediately ifcontainers overflow.8. Dispose waste off-site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surfacewaters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes fromconstruction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains,streams or wetlands unless there is no alternative reasonably available. If 50 footoffset is not attainable, provide relocation of portable toilet behind silt fence or placeon a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in highfoot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material.Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replacewith properly operating unit.HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with labelrestrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with thelabel, which lists directions for use, ingredients and first aid steps in case ofaccidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding ispossible or where they may spill or leak into wells, stormwater drains, ground wateror surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with localand state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and inaddition place the mixer and associated materials on impervious barrier and withinlot perimeter silt fence.4. Install temporary concrete washouts per local requirements, where applicable. If analternate method or product is to be used, contact your approval authority forreview and approval. If local standard details are not available, use one of the twotypes of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalksections. Stormwater accumulated within the washout may not be pumped into ordischarged to the storm drain system or receiving surface waters. Liquid waste mustbe pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless itcan be shown that no other alternatives are reasonably available. At a minimum,install protection of storm drain inlet(s) closest to the washout which could receivespills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stoneentrance pad in front of the washout. Additional controls may be required by theapproving authority. 8. Install at least one sign directing concrete trucks to the washout within the projectlimits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limitoverflow events. Replace the tarp, sand bags or other temporary structuralcomponents when no longer functional. When utilizing alternative or proprietaryproducts, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose ofin an approved disposal facility. Fill pit, if applicable, and stabilize any disturbancecaused by removal of washout. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen-material stockpile areas at least50 feet away from storm drain inlets, sediment basins, perimeter sediment controlsand surface waters unless it can be shown no other alternatives are reasonablyavailable. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset offive feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordancewith the approved plan and any additional requirements. Soil stabilization is definedas vegetative, physical or chemical coverage techniques that will restrain acceleratederosion on disturbed soils for temporary or permanent control needs. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Note: After the permanent cessation of construction activities, any areas with temporaryground stabilization shall be converted to permanent ground stabilization as soon aspracticable but in no case longer than 90 calendar days after the last land disturbingactivity. Temporary ground stabilization shall be maintained in a manner to render thesurface stable against accelerated erosion until permanent ground stabilization is achieved. Site Area Description Timeframe variations -7 days for perimeter dikes, swales,ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed unlessthere is zero slope Stabilize within thismany calendardays after ceasingland disturbance 7 7 7 14 None None (a) Perimeter dikes,swales, ditches, andperimeter slopes (b) High Quality Water(HQW) Zones (c) Slopes steeper than3:1 If slopes are 10' or less in length and arenot steeper than 2:1, 14 days areallowed (d) Slopes 3:1 to 4:1 (e) Areas with slopesflatter than 4:1 14 -7 days for slopes greater than 50' inlength and with slopes steeper than 4:1 -7 days for perimeter dikes, swales,ditches, perimeter slopes and HQWZones -10 days for Falls Lake Watershed NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF-INSPECTION Self-inspections are required during normal business hours in accordance with the tablebelow. When adverse weather or site conditions would cause the safety of the inspectionpersonnel to be in jeopardy, the inspection may be delayed until the next business day onwhich it is safe to perform the inspection. In addition, when a storm event of equal to orgreater than 1.0 inch occurs outside of normal business hours, the self-inspection shall beperformed upon the commencement of the next business day. Any time when inspectionswere delayed shall be noted in the Inspection Record. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. Theapproved E&SC plan must be kept up-to-date throughout the coverage under this permit.The following items pertaining to the E&SC plan shall be kept on site and available forinspection at all times during normal business hours. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical: (a) This General Permit as well as the Certificate of Coverage, after it is received. (b) Records of inspections made during the previous twelve months. The permittee shallrecord the required observations on the Inspection Record Form provided by theDivision or a similar inspection form that includes all the required elements. Use ofelectronically-available records in lieu of the required paper copies will be allowed ifshown to provide equal access and utility as the hard-copy records. PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that Must be Reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: ·They are 25 gallons or more, ·They are less than 25 gallons but cannot be cleaned up within 24 hours, ·They cause sheen on surface waters (regardless of volume), or ·They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA(Ref: 40 CFR 302.4) or G.S. 143-215.85. (d) Anticipated bypasses and unanticipated bypasses. (e) Noncompliance with the conditions of this permit that may endanger health or theenvironment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contactthe appropriate Division regional office within the timeframes and in accordance with theother requirements listed below. Occurrences outside normal business hours may also bereported to the Department's Environmental Emergency Center personnel at (800)858-0368. 3. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn downfor maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather).Non-surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non-surface withdrawal and the specific time periods or conditions in which it will occur. The non-surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non-surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION EROSION CONTROL DETAILC3.5 CONSTRUCTION SPECIFICATIONS: 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. 3. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTENANCE: 1. MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS.CONSTRUCTION ENTRANCE DETAIL TEMPORARY GRAVEL 100' M I N . 20' MIN. 40' MIN. NOT TO SCALE CE MATERIAL: 1. USE SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFIN OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D 6461. 2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.33 LB/LINEAR FT STEEL WITH A MINIMUM LENGTH OF 4 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. SILT FENCE DETAIL CONSTRUCTION SPECIFICATIONS: CONSTRUCTION: 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE GROUND SURFACE. 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO THE POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPEFROM THE BARRIER. 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE: 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUTS 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED.18" MAX.4" MIN.4'-0" MIN.FLOW NOTE: IMMEDIATELY. 12". REPAIR ANY UNDERMINE REMOVE SEDIMENT DEEPER THAN 8" MIN. SF SILT FENCE OUTLET DETAIL NOT TO SCALESFO NOT TO SCALE MAINTENANCE INSPECT DAM AND CHANNELS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE CHANNEL WHEN NEEDED. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS AROUND DAM, ADDITIONAL MEASURES CAN BE TAKEN SUCH AS, INSTALLING A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL (PRACTICE 6.31, RIPRAP-LINE AND PAVED CHANNELS). REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE DAM, AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONES TO DAM AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. CONSTRUCTION SPECIFICATIONS 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLEMATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. MAINTENANCE INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVESEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELYSTABILIZE IT. TD 6' (TYP.)6' (TYP.) 2' MIN. FLOW 18"MIN.COMPACTED SOIL TEMPORARY DIVERSIONS SCALE: N.T.S. 1 2 CROSS SECTION FRONT VIEW TOP VIEW CLASS "B" STONE FOR EROSIONSTRUCTURAL STONE SHALL BE CONTROL PURPOSES. SEDIMENTCONTROL STONE SHALL BE#5 OR #57 STONE. OUTLETS TO BE PLACED ATLOW POINTS ALONG SILT FENCE. 1. NOTES: 2. 24" 18" MIN. FLOW SILT FENCE SILT FENCE 12" MAX. CONSTRUCTION SPECIFICATIONS 1. PLACE STONE TO THE LINES AND DIMENSIONS SHOWN IN THE PLAN ON A FILTER FABRIC FOUNDATION. 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL GROUND LEVEL WHERE THE DAM ABUTS THE CHANNEL BANKS. 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BANK TO KEEP WATER FROM CUTTING AROUND THE ENDS OF THE CHECK DAM. 4. PROTECT THE CHANNEL AFTER THE DAM FROM HEAVY FLOW THAT COULD CAUSE EROSION. 6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE. 7. ENSURE THAT OTHER AREAS OF THE CHANNEL, SUCH AS CULVERT ENTRANCES BELOW THE DAM, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES. 8. SEE SILT FENCE DETAIL FOR CONSTRUCTION SPECIFICATIONS. WATERFILTERED WEIR4' MAX 19 GUAGE HARDWARE CLOTH -1/4" OPENINGS TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE TOP OF THE WASHED STONE. STEEL POST SEE SILT FENCE DETAIL INSTALL FILTER FABRIC UNDER RIP RAP AND GRAVEL NATURAL GROUND 12" THICK SEDIMENT CONTROL STONE STRUCTURAL STONE 2"-3" COURSE AGGREGATE @ 6" DEEP MINIMUM WITH FILTER FABRIC UNDERLINER WOVEN GEOSYNTHETICFILTER FABRIC STEEL POSTS 8' O.C. WITH WIREEXTEND FABRIC AND WIRE INTO TRENCH COMPACTEDBACKFILL Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION EROSION CONTROL DETAILC3.6 RIP RAP OUTLET PROTECTION CONSTRUCTION SPECIFICATIONS 1. ENSURE THAT THE SUBGRADE FOR THE FILTER AND RIPRAP FOLLOWS THE REQUIRED LINES AND GRADES SHOWN IN THE PLAN. COMPACT ANY FILL REQUIRED IN THE SUBGRADE TO THE DENSITY OF THE SURROUNDING UNDISTURBED MATERIAL. LOW AREAS IN THE SUBGRADE ON UNDISTURBED SOIL MAY ALSO BE FILLED BY INCREASING THE RIPRAP THICKNESS. 2. THE RIPRAP AND GRAVEL FILTER MUST CONFORM TO THE SPECIFIED GRADING LIMITS SHOWN ON THE PLANS. 3. FILTER CLOTH, WHEN USED, MUST MEET DESIGN REQUIREMENTS AND BE PROPERLY PROTECTED FROM PUNCHING OR TEARING DURING INSTALLATION.REPAIR ANY DAMAGE BY REMOVING THE RIPRAP AND PLACING ANOTHER PIECE OF FILTER CLOTH OVER THE DAMAGED AREA. ALL CONNECTING JOINTS SHOULD OVERLAP SO THE TOP LAYER IS ABOVE THE DOWNSTREAM LAYER A MINIMUM OF 1FOOT. IF THE DAMAGE IS EXTENSIVE, REPLACE THE ENTIRE FILTER CLOTH. 4. RIPRAP MAY BE PLACED BY EQUIPMENT, BUT TAKE CARE TO AVOID DAMAGING THE FILTER. 5. THE MINIMUM THICKNESS OF THE RIPRAP SHOULD BE 1.5 TIMES THE MAXIMUM STONE DIAMETER. 6. RIPRAP MAY BE FIELD STONE OR ROUGH QUARRY STONE. IT SHOULD BE HARD, ANGULAR, HIGHLY WEATHER-RESISTANT AND WELL GRADED. 7. CONSTRUCT THE APRON ON ZERO GRADE WITH NO OVERFILL AT THE END. MAKE THE TOP OF THE RIPRAP AT THE DOWNSTREAM END LEVEL WITH THE RECEIVING AREA OR SLIGHTLY BELOW IT. 8. ENSURE THAT THE APRON IS PROPERLY ALIGNED WITH THE RECEIVING STREAM AND PREFERABLY STRAIGHT THROUGHOUT ITS LENGTH. IF A CURVE IS NEEDED TOFIT SITE CONDITIONS, PLACE IT IN THE UPPER SECTION OF THE APRON. 9. IMMEDIATELY AFTER CONSTRUCTION, STABILIZE ALL DISTURBED AREAS WITH VEGETATION (PRACTICES 6.10, TEMPORARY SEEDING, AND 6.11, PERMANENT SEEDING). MAINTENANCE INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE.NOT TO SCALE OP SECTION A-A INLET PROTECTION IS IN PLACE.OFF INLET STRUCTURES WHILE INLET TOPS TO REMAIN NOTE: INLET PLAN A A FILTEREDWATER 4' MAX. 2:1 INLET WALL HARDWARE CLOTH & GRAVEL NOT TO SCALE IP INLET PROTECTION DETAIL CONSTRUCTION SPECIFICATIONS: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THEINLET. 2. DRIVE 5' STEEL POST 2' INTO THE GROUND SURROUNDING THEINLET SPACE POSTS EVENLY AROUND THE PERIMETER ON THEINLET, MAX. 4' APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH.SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLEAND BOTTOM. PLACING A 2' FLAP OF THE WIRE MESH UNDER THEGRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON A 2:1 SLOPEWITH A HEIGHT OF 16" AROUND THE WIRE, AND SMOOTH TO ANEVEN LEVEL. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED,REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADINGELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH GROUNDCOVER. MAINTENANCE: INSPECT INLETS AT LEAST WEEKLY AND AFTEREACH SIGNIFICANT (1/2" OR GREATER) RAINFALLEVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHEROBJECTS TO PROVIDE ADEQUATE FLOW FORSUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THEWIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. 3' 2'16" 2' NCDOT #5 OR #57WASHED STONE 19-QUAGE HARDWARE CLOTH (1 4" MESH OPENINGS) STEEL POSTSWITH WIRE MESH NCDOT #5 OR #57 WASHED STONE NOTES: 1. ACTUAL LAYOUT TO BE DETERMINED IN FIELD. 2. THE "CONCRETE WASHOUT" SIGN SHALL BE INSTALLED WITHIN 30 FEET OF THE TEMPORARY CONCRETE WASHOUT FACILITY. 3. PIT CAPACITY IS MINIMUM OF 6 CUBIC FEET PER 10 CUBIC YARDS OF CONCRETE. PLAN VIEWSFSFSFSF SECTION A-A B SECTION B-B B A "CONCRETE WASHOUT" SIGN DETAILS CONCRETEWASHOUTAVEHICLE ENTRANCE6" WASH STONE 2:1 TOP RIM OF STONE BERM LINEDPITSUMP 2:11' 1' 2'1'6' 25' MINIMUM15' 1' 2'2'2' VEHICLE ENTRANCE @ 2% SLOPE 10 MIL. PLASTIC LINING PIT SUMP "CONCRETE WASHOUT" SIGN(SEE NOTE 2)2:1SILTFENCE SILTFENCE SILTFENCE 10 MIL. PLASTIC LINING PIT SUMP ANCHOR PLASTIC LINER WITH #57 STONE BERM ANCHOR PLASTIC LINERWITH #57 STONE BERM 2:11' 1' 2'1'6' 20' 1' 2'2'2'2'2' 1' 1' 1' SILT FENCE SIDE VIEW FRONT VIEW 0.5" LAGSCREWS 3' 3' 3"x3"x8'WOODPOSTS PLYWOOD 48"x24"PAINTED WHITE BLACKLETTERS 6"HEIGHT 2' 4' KEY IN REMOVABLE LINING CONCRETE WASHOUT PIT NOT TO SCALE CWP MAINTENANCE : 1. MAINTAINING TEMPORARY CONCRETE WASHOUT SHALL INCLUDEREMAINING AND DISPOSING OF HARDENED CONCRETE AND / ORSLURRY AND RETURNING THE FACILITIES TO A FUNCTIONALCONDITION. 2. FACILITY SHALL BE CLEANED OR RECONSTRUCTED IN A NEW AREAONCE WASHOUT BECOMES TWO-THIRDS Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION EROSION CONTROL DETAILC3.7 GENERAL NOTES : 1. PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGEPIPE. 2. PROPER ORIFICE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OF TIME. MODIFICATIONS MAY BE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE. 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE DISCHARGE END OF THE PIPE. 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUTSHEET, AND INSTRUCTIONS ON WEB SITE FOR EACH SIZE. SKIMMER DEWATERING DEVICE NOT TO SCALE MAINTENANCE 1. PULL SKIMMER OVER TO THE SIDE OF BASIN AND REMOVE DEBRIS AND EXCESS SEDIMENTS THAT HAVE ACCUMULATED FROM RAINFALL EVENTS. 2. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, JERK THE SKIMMER TO BOB UP AND DOWN TO DISLODGE THE DEBRIS AND RESTORE FLOW. CHECK ORIFICE INSIDE THE SKIMMER FOR CLOGGING AND REMOVE AS NEEDED. 3. IF SKIMMER ARM OR BARREL PIPE IS CLOGGED, REMOVE THE ORIFICE AND THE OBSTRUCTION CAN BE CLEAREDWITH PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. 1. CLEAR, GRUB, AND STRIP AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THEEMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL (TYPICALLY 4-INCH SCHEDULE 40 PVC PIPE) ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PREVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS A BACK FILL AROUND THE PIPE. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM THE FIRM CONTRACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACK FILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT, IN NO CASE SHOULD THE PIPE CONDUITBE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURES INSTRUCTIONS, OR AS DESIGNED. 6. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE. 7. EARTHEN SPILLWAYS - INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, ANDENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH THE LAMINATED PLASTIC OR IMPERMEABLE GEO TEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOMAND SIDES AND EXTEND ONTO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8-INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUSTBE ONE PIECE, NOT JOINED OR SPLICED; OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTIONSSHOULD OVERLAP THE LOWER SECTIONS SO THAT WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. (ADAPTED FROM " A MANUAL FOR DESIGNING, INSTALLING AND MAINTAINING SKIMMER SEDIMENT BASINS." FEBRUARY 1999 J.W. FAIR CLOTH & SON.) 8. INLETS - DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECTION). 9. EROSION CONTROL - CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENTBEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION ( REFERENCES: SURFACE STABILIZATION). 10. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65 11. AFTER ALL THE SEDIMENT-PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED,REMOVE THE STRUCTURE AND AIL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY ( REFERENCES: SURFACE STABILIZATION). INSPECT SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE BATTLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE-ANCHOR THE BAFFLES IF WATER IS FLOWINGUNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLYJERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE AND REMOVE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER FOR DEBRIS. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH THE FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. CONSTRUCTION SPECIFICATION MAINTENANCE SB SCALE: N.T.S. SEDIMENT BASIN INLET F L O W 5' WID T H SUPPORT ROPETO WIRE TO PREVENT SAGGING STAKE TO SUPPORT WIRE BAFFLE SECTION BAFFLE PLAN STEEL POST (TYP.) CONSTRUCTION SPECIFICATIONS: GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. INSTALL POSTS OR SAW HORSES ACROSS THE WIDTH OF THE SEDIMENT TRAP. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24", SPACED A MAXIMUM OF 4' APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THE FABRIC SHOULD BE 6" HIGHER THAN THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2" LOWER THAN THE TOP OF THE BERMS. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND OUTLET DISHARGE POINT. BASINS LESS THAN THE TOP OF THE BERMS. WHEN USING POSTS, ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. WRAP POROUS MATERIAL, LIKE JUTE BACKED BY COIR MATERIAL, OVER A SAWHORSE OR THE TOP WIRE. HAMMER REBAR INTO THE SAWHORSE LEGS FOR ANCHORING. THE FABRIC SHOULD HAVE FIVE TO TEN PERCENT OPENINGS IN THE WEAVE. ATTACH FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH ZIP TIES, WIRE OR STAPLES. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED IN A TRENCH OR PINNED WITH 8" EROSION CONTROL MATTING STAPLES. DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN MAINTENANCE: INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLECOLLAPSE, TEAR DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS WHEN IT REACHED HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PROESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DURING CLEANOUT. SEDIMENT DEPTHSHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. AFTER CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE, AND STABILIZE IT. COIR MESH OR SIMILAR,STAPLED OR TRENCHEDINTO BOTTOM OR SIDE INLET ZONE35% OF SURFACE AREA FIRST CHAMBER 25% OF SURFACE AREA OUTLET OUTLET ZONE 15% OF SURFACE AREA SECOND CHAMBER25% OF SURFACE AREA BAFFLE (TYP.) SUPPORT POST 24" INTO BOTTOM OR SIDE (TYP.) BAFFLES FOR TEMPORARY SEDIMENT TRAPS NOT TO SCALEBF STANDARD SKIMMER ATTACHED TO PERMANENT RISER NOTES: 1. BASIN SHOULD BE CLEANED OUT WHEN CAPACITY REACHES AN ELEVATION REPRESENTING THAT THE BASIN IS HALF-FULL 2. THE TARP USED TO PROTECT THE WEIR SHALL BE THE WIDTH SPECIFIED. THE LENGTH OF THE TARP SHALL BE ACCORDING TO AVAILABLE SUPPLY. IF MULTIPLE TRAPS ARE TO BE USED, THEN TARPS SHALL BE OVERLAPPED AT LEAST 12". THE UPSTREAM 12" TARP SHALL OVERLAP THE DOWNSTREAM TARP. THE TARP SHALL BE 50 MIL HEAVY DUTY SILVER TARPAULINS OR EQUIVALENT FOR U.V. RESISTANCE 3. PROVIDE MINIMUM OF THREE POROUS BAFFLES TO EVENLY DISTRIBUTE FLOW ACROSS THE BASIN, REDUCING TURBULENCE. 4. BAFFLE MATERIAL MUST BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR A SILT FENCE.5. MOST OF THE SEDIMENT WILL ACCUMULATE IN THE FIRST DAY, SO THIS SHOULD BE READILY AVAILABLE FOR MAINTENANCE. 6. DURING THE CONSTRUCTION PHASE OF THE PROJECT, PERMANENT STORMWATER RISER SHALL ONLYDEWATER FROM THE TOP OF THE PIPE. 7. POND SHALL NOT BE CONVERTED FOR STORMWATER USE UNTIL APPROVED BY ENVIRONMENTAL ENGINEER. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION W W W W W W WWW W W SSSS1 4 5 10 16 30 SS SS SS SS SS SS SS SS SS SS SS SS WWW WC2L4OHU TOMMY LYNN MCPHAIL AND WIFE,BONNIE H. MCPHAILDEED BOOK 684, PAGE 606PIN: 0524-58-4260.000PID: 010534 0079 01 6+004+504+002+502+00 5+00 5+500+50 3+00 3+50 HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)0+00 1+00 1+50 PC =6+17.30Rad =230.00'6+50 PT =6+56.46PC =6+56.46Rad =230.00'7+00 7+5 0<<97 LF - 8" SDR-26 PVC @ 2.64%<<180 LF - 8" SDR-26 PVC @ 0.40%<<97 LF - 8" SDR-26 PVC @ 0.40%<<1 1 9 L F - 8 " S D R - 2 6 P V C @ 1 . 0 0 % <<108 LF - 8" S D R - 2 6 P V C @ 0 . 4 0 % <<203 LF - 8" SDR-26 PVC @ 0.40%<<202 LF - 8" SDR-26 PVC @ 0.40% 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+5 00+000+501+000+000+501+000+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+0 00+000+501+000+000+501+0010.0' DRN.ESMT 10.0' DRNESMT.CI-27CI-8SMH-9STA 0+97RIM = 168.88'INV IN = 159.06'INV OUT = 158.96'EX SMH6' DIA DOGHOUSE MH(TO BE INSTALLED BY OTHERSAS PART OF McPHAIL FARMPROJECT)RIM = 172.34'±EX. INVERT = 149.25'±INVERT IN = 155.93'PROVIDE INSIDE DROP TIE TO EX. 6" WATER MAIN:1 - 6"X6" TEE1- 6"GATE VALVESEE DETAIL SHEET FORWRAP AROUND ASSEMBLY EX. 30" UTILITY EASEMENT16" GRAVITY SEWER SMH-1STA 1+80RIM = 169.89'INV IN = 158.50'(SMH-7)INV IN = 156.75'(SMH-2)INV OUT = 156.65' 6" C-900 PVCWATER LINE SITE TRIANGLE(TYP.) SEWER SERVICE(TYP)WATER SERVICE(TYP) CI-28 SMH-2STA 3+82RIM = 168.81'INV IN = 157.66'INV OUT = 157.56' 6" C-900 PVCWATER LINESTA. 1+88.00COMPLETEFIRE HYDRANTASSEMBLY - SEESHEET C-4.4 FORWATERLINE STATIONS STA. 2+04.001 - 6"X6" TEE3 - 6" GATE VALVE STA. 5+60.00COMPLETEFIRE HYDRANTASSEMBLY - SEESHEET C-4.4 FORWATERLINE STATIONS CI-11 CI-10 STA. 5+95.001 - 6"X6" TEE3 - 6"GATE VALVE CI-7 SMH-3STA 5+85RIM = 169.07'INV IN = 158.57'(SMH-9)INV IN = 158.57'(SMH-4)INV OUT = 158.47'SMH-4STA 6+93RIM = 168.57'INV IN = 159.10'INV OUT = 159.00' STA. 6+35.001-6" 22.5° BEND CI-6 EX. 6" WATER LINE CI-12 CI-13CI-18 SMH-7STA 0+97RIM = 169.30'INV IN = 161.27'INV OUT = 161.07'16" STEEL CASING(SEE PROFILE)CI-9 HOR: 1" = 30 VERT: 1" = 5 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 << 203-LF 8" SDR-26 PVC @ 0.40% << 202-LF 8" SDR-26 PVC @ 0.40%<< 108-LF 8" SDR-26 PVC @ 0.40%EX. SMHSTA =0+00RIM = 172.34INV IN = 155.93EX. INV OUT = 146.25±SMH-1STA =1+80RIM = 169.89INV IN = 156.75INV IN = 158.50INV OUT = 156.65SMH-2STA =3+83RIM = 168.81INV IN = 157.66INV OUT = 157.56SMH-3STA =5+85RIM = 169.07INV IN = 158.57INV IN = 158.57INV OUT = 158.47SMH-4STA =6+93RIM = 168.57INV IN = 159.10INV OUT = 159.00NOTE:STATIONS REFERENCEDSANITARY SEWER CENTERLINE << 180-LF 8" SDR-26 PVC @ 0.40%INSIDE DROP15" RCPINV = ±166.7' 15" RCPINV = ±165.2' 15" RCPINV = ±165.5' PROPOSED GRADE EXISTING GRADE EX. 16" WL GRAVITYSEWER MAIN Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONNORTHBLACK FOREST DR - SANITARY SEWER PROFILE SCALE: HORIZ. 1"=30' VERT. 1"=5' BLACK FOREST DR - SANITARY SEWER & WATER LINE PLAN SCALE: 1"=30'SANITARY SEWER & WATER LINE PLANSANITARY SEWER PROFILEC4.0 FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT.CONTINUE FROM SHEET C-4.0MATCHLINE STA. 7+00MATCHLINE STA. 7+00BLACK FOREST DRIVE S S 1617SS SS SS SS SS33 7 6 . 7 5 '343536N 8 8 ° 0 1 ' 0 2 " E 7 1 5 . 6 9 ' T O T A L W W W WWW W7+00 7+50 8+00 8+50 9+0 0 9+ 5 0 PT =9+54.92<<1 2 4 L F - 8 " S D R - 2 6 P V C @ 2 . 6 7 % <<119 LF - 8" SDR-26 PVC @ 1.00% <<108 L F - 8 " S D R- 2 6 P V C @ 0. 4 0 % 7+00 7+50 8+00 8+50 9 + 0 0 9+5 0 10+0010+5010+8 6 . 3 0 7+00 7+50 8+00 8+5 0 9+0 0 9+3 6 . 2 1SMH-4STA 6+93RIM = 168.57'INV IN = 159.10'INV OUT = 159.00' SMH-5STA 8+13RIM = 168.88'INV IN = 160.39'INV OUT = 160.29' CI-25 CI-4 SMH-6STA 9+36RIM = 168.61'INV OUT = 163.68' 2' BLOWOFFASSEMBLY CI-5 STA. 8+67.00COMPLETEFIRE HYDRANTASSEMBLY - SEESHEET C-4.4 FORWATERLINE STATIONS CI-6 1 6 " S T E E L C A S I N G (S E E P R O F I L E ) CI-3 7+00 7+50 8+00 8+50 9+00 9+50 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 180 << 119-LF 8" SDR-26 PVC @ 1.00% << 124-LF 8" SDR-2 6 P V C @ 2 . 6 7 %STA =6+93RIM = 168.57INV IN = 159.10INV OUT = 159.00SMH-5STA =8+13RIM = 168.88INV IN = 160.39INV OUT = 160.29SMH-6STA =9+36RIM = 168.61INV OUT = 163.68NOTE:STATIONS REFERENCEDSANITARY SEWER CENTERLINE 15" RCPINV = ±165.5'15" RCPINV = ±165.4' Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSCALE IN FEET 0'15 30 60NORTHBLACK FOREST DR - SANITARY SEWER & WATER LINE PLAN SCALE: 1"=30'SANITARY SEWER & WATER LINE PLANSANITARY SEWER PROFILEC4.1 FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT.MATCHLINE STA 7+00CONTINUE TO SHEET C-4.1 BLACK FOREST DR SANITARY SEWER PROFILE SCALE: HORIZ. 1"=30' VERT. 1"=5'MATCHLINE STA. 7+00 WW W W W W W W W WSS SS SS SS SS SS SS 123252423SSSSSSSS22OHUEXISTING 40' UTILITY EASEMENT20' EITHER SIDE OF CENTER OF UTILITIES- DETERMINED BY CLEARING LIMITS -EX. SANITARYFORCE MAINSSMHRIM = 168.08INV = 148.982+502+003+000+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00PC =4+04.71Rad =2217.39'4+50 5+00 PT =5+09.601+50<<344 LF - 8" SDR-26 PVC @ 0.37%<<97 LF - 8" SDR-26 PVC @ 2.64%<<180 LF - 8" SDR-26 PVC @ 0.40%<<203 LF - 8" SDR-26 PVC @ 0.40%1+502+002+503+000+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 4+92.02 1+001+502+002+503+000+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+41.35 CI-17 CI-14 CI-15 CI-16 6" C-900 PVCWATER LINE STA. 3+91.00COMPLETEFIRE HYDRANTASSEMBLY WATER SERVICE(TYP) SEE SHEET C-4.4FOR WATER LINEPROFILES (TYP OF ALL)SMH-1STA 1+80RIM = 169.89'INV IN = 158.50'(SMH-7)INV IN = 156.75'(SMH-2)INV OUT = 156.65'SEWER SERVICE(TYP)WATER SERVICE(TYP)CI-28STA.1+88.00COMPLETEFIRE HYDRANTASSEMBLY - SEESHEET C-4.4 FORWATERLINE STATIONSSTA.2+04.001 - 6"X6" TEE3 - 6" GATE VALVECI-12CI-13CI-18SMH-7STA 0+97RIM = 169.30'INV IN = 161.27'INV OUT = 161.07' STREET LIGHTS(TYP) SMH-8STA 4+41.35RIM = 168.06'INV OUT = 162.55' 2" BLOWOFFASSEMBLY SEWER SERVICE(TYP) HOR: 1" = 30 VERT: 1" = 5 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 180 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 180 << 97-LF 8" SDR-26 P V C @ 2 . 6 4 % << 344-LF 8" SDR-26 PVC @ 0.37%SMH-1STA =0+00RIM = 169.89INV IN = 158.50INV IN = 156.75INV OUT = 156.65SMH-7STA =0+97RIM = 169.30INV IN = 161.27INV OUT = 161.07SMH-8STA =4+41RIM = 168.06INV OUT = 162.556" WL INV = ±164.4' NOTE:STATIONS REFERENCEDSANITARY SEWER CENTERLINE 15" RCPINV = ±166.2'15" RCPINV = ±165.6'15" RCPINV = ±165.0' 24" min.Separation PROPOSED GRADE EXISTING GRADE Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSTEPPING STONE LN - SANITARY SEWER PROFILE SCALE: HORIZ. 1"=30' VERT. 1"=5' STEPPING STONE LN - SANITARY SEWER & WATER LINE PLAN SCALE: 1"=30'SANITARY SEWER & WATER LINE PLANSANITARY SEWER PROFILEC4.2 FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT.NORTHBLACK FOREST DRIVESTEPPING STONE LANE WWSS SS SS SS SS SS SS 1011121314152928SSSSSSSSWWWWWWWWWW1,045.52'S 02°48'51" W 1.075.54' TOTALTWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03SSMHRIM = 168.85INV = 148.456+005+005+500+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+13.05 PC =6+17.30Rad =230.00'6+50PT =6+56.46PC =6+56.46Rad =230.00' <<340 LF - 8" SDR-26 PVC @ 1.06%<<97 LF - 8" SDR-26 PVC @ 0.40%<<108 LF - 8" SDR-26 PVC @ 0.40%<<202 LF - 8" SDR-26 PVC @ 0.40%5+005+506+006+507+000+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 4+94.22 5+005+506+006+500+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 10.0' DRN.ESMT10.0' DRNESMT.SEE SHEET C-4.4FOR WATER LINEPROFILES (TYP OF ALL) 6" WL C-900 PVCWATER LINE STA 3+93.00COMPLETEFIRE HYDRANTASSEMBLY WATER SERVICE(TYP) CI-24 CI-23 CI-22CI-8 CI-19 CI-20 CI-21 SMH-10STA 4+37RIM = 167.66'INV OUT = 162.66' SMH-9STA 0+97RIM = 168.88'INV IN = 159.06'INV OUT = 158.96' SEWER SERVICE(TYP) INSTALL CONCRETECOLLAR TO PROTECTWATER AND SEWERSERVICES 2" BLOWOFFASSEMBLY PROPOSEDSTREET LIGHT STA.5+60.00COMPLETEFIRE HYDRANTASSEMBLY - SEESHEET C-4.4 FORWATERLINE STATIONSCI-10STA.5+95.001 - 6"X6" TEE3 - 6"GATE VALVECI-7SMH-3STA 5+85RIM = 169.07'INV IN = 158.57'(SMH-9)INV IN = 158.57'(SMH-4)INV OUT = 158.47'INV OUT = 159.00'STA. 6+35.001-6" 22.5° BEND16" STEEL CASING(SEE PROFILE)CI-9HOR: 1" = 30 VERT: 1" = 5 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 180 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 180 << 97-LF 8" SDR-26 PVC @ 0.40% << 340-LF 8" SDR-26 PVC @ 1.06%SMH-3STA =0+00RIM = 169.07INV IN = 158.57INV IN = 158.57INV OUT = 158.47SMH-9STA =0+97RIM = 168.88INV IN = 159.06INV OUT = 158.96SMH-10STA =4+37RIM = 167.66INV OUT = 162.66NOTE:STATIONS REFERENCEDSANITARY SEWER CENTERLINE 30" RCPINV = ±161.8' 15" RCPINV = ±165.0' 15" RCPINV = ±165.3'6" INV = ±165.2' 24" MIN. SEPARATION 24" MIN. SEPARATION PROPOSED GRADE EXISTING GRADE 20 LF 16" STEELCASING CENTEREDUNDER STORM DRAINAGE Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONBOOKRAND LN - SANITARY SEWER PROFILE SCALE: HORIZ. 1"=30' VERT. 1"=5' BOOKRAND LN - SANITARY SEWER & WATER LINE PLAN SCALE: 1"=30'SANITARY SEWER & WATER LINE PLANSANITARY SEWER PROFILEC4.3 FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT.NORTHBLACK FOREST DRIVEBOOKRAND LANE 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 170.9170.91171.7171.70171.1171.13169.9169.86169.7169.69169.4169.40169.8169.77169.9169.88169.4169.38168.9168.93168.4168.38168.8168.77168.6168.60169.1169.15169.1169.05169.0169.02169.1169.11STA =2+03.64Stub Rd-SouthEL = 170.03STA =5+96.42Stub Rd-NorthEL = 169.25CL STA =2+15.618" SDR-26 PVCINV = ±159.1'CL STA =2+64.7624" RCPINV = ±163.3'CL STA =5+74.4624" RCPINV = ±162.4'CL STA =6+20.838" SDR-26 PVCINV = ±158.7'CL STA =6+55.2130" RCPINV = ±161.6'NOTE:STATIONS REFERENCEDWATERLINE CENTERLINE TIE TO EX. 6" WATER MAIN -SEE DETAIL SHEET FORWRAP AROUND ASSEMBLYOR USE STRAIGHT TEE CONNECTIONWITH 6" WL TEE BORE AND JACK6" WL WATER LINE STA. 1+88FIRE HYDRANTASSEMBLY STA. 2+041 - 6" X 6" TEE3 - 6" GATE VALVE STA. 5+60FIRE HYDRANTASSEMBLY STA. 5+951 - 6"X 6" TEE3 - 6" GATE VALVEPROPOSED GRADEOVER WATERMAIN PROPOSED GRADEOVER WATERMAIN 20 LF 12" STEELCASING CENTEREDUNDER STORM DRAINAGE 8" SDR-26 SANITARYSEWER MAIN 8" SDR-26 SANITARYSEWER MAIN 6" C-900 PVCWATER LINE SMH-5CI-5CI-6SMH-4CI-8SMH-3CI-9CI-11SMH-2CI-12CI-13SMH-1CI-18CI-10CI-7EX SMH8+50 9+00 9+50 10+00 10+50 11+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 168.6168.56168.5168.46168.6168.57CL STA =9+59.4736" RCPINV = ±160.1'2" BLOWOFF STA. 8+67FIRE HYDRANTASSEMBLY 15" RCP 6" C-900 PVCWATER LINE CI-3SMH-6CI-4SMH-5CI-290+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 169.5169.53169.4169.38169.4169.41169.2169.24169.3169.27169.2169.23169.2169.16169.1169.06168.8168.83NOTE:STATIONS REFERENCEDWATERLINE CENTERLINE STA. 3+91.00FIRE HYDRANTASSEMBLY 8" SDR-26SAN SEWER MAIN STORM DRAINAGESYSTEM 2" BLOWOFF 60 LF PR 350RESTRAINT JOINT DIP 6" WL C-900 PVCWATER LINE PROPOSED GRADEOVER WATERMAIN SMH-8CI-16CI-17SMH-7CI-180+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 169.0168.98168.8168.84169.0169.02168.7168.69168.0168.02168.3168.35168.3168.28168.5168.47168.3168.32STA =2+03.64Stub Rd-SouthEL = 170.03CL STA =0+19.3724" RCPINV = ±162.3'NOTE:STATIONS REFERENCEDWATERLINE CENTERLINE 2" BLOWOFF STA. 3+93.00FIRE HYDRANTASSEMBLY 8" SAN SEWER MAIN 60 LF PR 350RESTRAINT JOINT DIP 6" C-900 PVCWATER LINE PROPOSED GRADEOVER WATERMAIN STORM DRAINAGESYSTEM SMH-10CI-21CI-20CI-19SMH-9CI-9Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONBOOKRAND LN - WATER LINE PROFILE BLACK FOREST DR - WATER LINE PROFILE WATER LINE PROFILESC4.4 FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT.MATCHLINE STA. 7+75 (THIS SHEET)MATCHLINE STA. 7+75 (THIS SHEET)STEPPING STONE LN - WATER LINE PROFILEBLACK FOREST DR - WATER LINE PROFILE SCALE: HORIZ. 1"=30' VERT. 1"=5' SCALE: HORIZ. 1"=30' VERT. 1"=5' SCALE: HORIZ. 1"=30' VERT. 1"=5' SCALE: HORIZ. 1"=30' VERT. 1"=5' Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONHARNETT COUNTY UTILITY NOTESC4.5 2022 HRW REQUIRED UTILITY NOTES (Revision 10- April 19, 2022) The following utility notes should be added to the coversheet of utility plans for projects located in Harnett County: WATER A.The Fire Marshal's Office shall approve all hydrant types and locations in new subdivisions. However, Harnett Regional Water (HRW)prefers the contractors to install one of the following fire hydrants: 1.Mueller - Super Centurion 250 A-423 model with a 5¼” main valveopening three way (two hose nozzles and one pumper nozzle);2.American Darling - Mark B-84-B model with a 5¼” main valve openingthree way (two hose nozzles and one pumper nozzle);3.Waterous - Pacer B-67-250 model with a 5¼” main valve opening threeway (two hose nozzles and one pumper nozzle) or approved equal forstandardization. *All fire hydrants listed above must have “American National Fire Hose Connection Screw Threads” NST/NH hose threads. B.Fire hydrants are installed at certain elevations. Any grade change near any fire hydrant, which impedes its operation, shall become the responsibility of the Utility Contractor for correction. Corrections will be monitored by the HRW Utility Construction Inspector and the Harnett County Fire Marshal. C.The Professional Engineer (PE) shall obtain and provide the NCDEQ “Authorization to Construct” permit to the Utility Contractor before the construction of the water line shall begin. The Utility Contractor must post a copy of the NCDEQ “Authorization to Construct” permit issued by the North Carolina Department of Environmental Quality (NCDEQ) on site prior to the start of construction. The permit must be maintained on site throughout the entire construction process of the proposed water lines that will serve this project. D.The Utility Contractor shall notify Harnett Regional Water (HRW) and the Professional Engineer (PE) at least two days prior to construction commencing. The Utility Contractor must schedule a pre-construction conference with Mr. Chad Everette, HRW Utility Construction Inspector at least two (2) days before construction will begin and the Utility Contractor must coordinate with HRW for regular inspection visitations and acceptance of the water system(s). Construction work shall be performed only during the normal working hours of HRW which is 8:00 am - 5:00 pm Monday through Friday. Holiday and weekend work is not permitted by HRW. The Professional Engineer (PE) shall provide HRW and the Utility Contractor with a set of NCDEQ approved plans marked“Released for Construction” at least two days prior to construction commencing. The Registered Land Surveyor (RLS) should stake out all lot corners and the grade stakes for the proposed finish grade for each street before the Utility Contractor begins construction of the water line(s). The grade stakes should be set with a consistent offset from the street centerline so as not to interfere with the street grading and utility construction. A.The Utility Contractor shall provide the HRW Utility Construction Inspector with material submittals and shop drawings for all project materials prior to the construction of any water line extension(s), and associated water services in Harnett County. The materials to be used on the project must meet the established specifications of HRW and be approved by the Engineer of Record prior to construction. All substandard materials or materials not approved for use in Harnett County found on the project site must be removed immediately when notified by the HRW Utility Construction Inspector. B.The water main(s), fire hydrants, service lines, meter setters and all associated appurtenances shall be constructed in strict in accordance with the standard specifications of the Harnett Regional Water (HRW). The Utility Contractor shall be responsible to locate the newly installed water main(s), water service lines and all associated meter setters and meter boxes for other utility companies and their contractors until the new water main(s) have been approved by the North Carolina Department of Environmental Quality, Division of Environmental Health, Public Water Supply Section (NCDEQ, DEH, PWS) and accepted by HRW. C.Prior to acceptance, all services will be inspected to ensure that they are installed at the proper depth. All meter boxes must be flush with the ground level at finish grade and the meter setters must be a minimum of 8” below the meter box lid. Meter setters shall be centered in the meter box and supported by brick, block or stone. D.The Utility Contractor shall notify Harnett Regional Water (HRW) and the Professional Engineer (PE) at least two days prior to construction commencing. The Utility Contractor must schedule a pre-construction conference with Mr. Chad Everette, HRW Utility Construction Inspector at least two (2) days before construction will begin and the Utility Contractor must coordinate with HRW for regular inspection visitations and acceptance of the water system(s). Construction work shall be performed only during the normal working hours of HRW which is 8:00 am - 5:00 pm Monday through Friday. Holiday and weekend work is not permitted by HRW. E.The Professional Engineer (PE) shall provide HRW and the Utility Contractor with a set of NCDEQ approved plans marked “Released for Construction” at least two days prior to construction commencing. The Registered Land Surveyor (RLS) should stake out all lot corners and the grade stakes for the proposed finish grade for each street before the Utility Contractor begins construction of the water line(s). The grade stakes should be set with a consistent offset from the street centerline so as not to interfere with the street grading and utility construction. F.Potable water mains crossing other utilities and non-potable water lines (sanitary sewer, storm sewer, RCP, etc.) shall be laid to provide a minimum vertical distance of twenty-four (24”) inches between the potable water main and all other utilities. NCDOT requires the new water mains to be installed under the storm water lines. The potable water main shall be installed with twenty-four (24”) inches of vertical separation and with ductile iron pipe when designed to be placed under a non- potable water line such as sanitary sewer or storm sewer lines. If these separations cannot be maintained then the water main shall be installed with ductile iron pipe. Both the potable water main and the non-potable water line must be cast iron or ductile iron pipe (DIP) if the state minimum separations cannot be maintained. The ductile iron pipe must be laid so the mechanical joints are at least (10') feet from the point where the potable water main crosses the non-potable water line. G.Potable water mains installed parallel to non-potable water lines (sanitary sewer, storm sewer, RCP, etc.) shall be laid to provide a minimum horizontal distance of ten (10') feet between the potable water main and sanitary sewer mains, sewer laterals and services. The horizontal separation between the potable water main and any other utility or storm sewer shall not be less than five (5') feet. The potable water main must be ductile iron pipe if this horizontal separation of ten (10') feet cannot be maintained. The ductile iron pipe shall extend at least ten (10') feet beyond the point where the minimum required horizontal separation of ten (10') feet can be re-established. H.Meter setters shall be installed in pairs on every other lot line where possible to leave adequate space for other utilities to be installed at a later time. The meter setters shall be installed at least one (1') foot inside the right-of-way and at least three (3') to five (5') feet from the property line between the lots. I.HRW requires that meter boxes for ¾” services shall be 12” wide x 17” long ABS plastic boxes at least 18” in height with cast iron lids/covers. Meter boxes for 1” services shall be 17” wide x 21” long ABS plastic boxes at least 18” in height with plastic lids and cast iron flip covers in the center of the lids. Meter boxes for 2” services shall be 20” wide x 32” long ABS plastic boxes at least 20” in height with plastic lids and cast iron flip covers in the center of the lids. J.Master meters must be installed in concrete vaults sized for the meter assembly and associated appurtenances so as to provide at least eighteen (18”) inches of clearance between the bottom of the concrete vault and the bottom of the meter setter. The master meter must be provided test ports if the meter is not equipped with test ports from the manufacturer in accordance with the HRW established standard specifications and details. Ductile iron pipe must be used for the master meter vault piping and valve vault piping. The Utility Contractor must provide shop drawings for the meter vaults to HRW prior to ordering the concrete vaults. K.The Utility Contractor will install polyethylene SDR-9 water service lines that cross under the pavement inside a schedule 40 PVC conduit to allow for removal and replacement in the future. Two (2) independent ¾” water service lines may be installed inside one (1) - two (2”) inch schedule 40 PVC conduit or two (2) independent 1” water service lines may be installed inside one (1)- three (3”) inch schedule 40 PVC conduit, but each water service shall be tapped directly to the water main. Split services are not allowed by HRW. If sidewalks are proposed, the conduit must extend past the sidewalk. L.The water main(s), fire hydrants, gate valves, service lines, meter setters and associated appurtenances must be rated for 200 psi and hydrostatically pressure tested to 200 psi. The hydrostatic pressure test(s) must be witnessed by the HRW Utility Construction Inspector. The Utility Contractor must notify HRW when they are ready to begin filling in lines and coordinate with Harnett Regional Water to witness all pressure testing. M.The Utility Contractor shall conduct a pneumatic pressure test using compressed air or other inert gas on the stainless steel tapping sleeve(s) prior to making the tap on the existing water main. This pneumatic pressure test must be witnessed by the HRW Utility Construction Inspector. The Utility Contractor shall use Romac brand stainless steel tapping sleeve(s) or approved equal for all taps made in Harnett County. All new water line extensions must begin with a resilient wedge type gate valve sized equal to the diameter of the new water line extension in order to provide a means of isolation between Harnett Regional Water's existing water mains and the new water line extensions under construction. N.All water mains will be constructed with SDR-21 PVC Pipe or Class 50 Ductile Iron Pipe rated for at least 200 psi or greater. All pipes must be protected during loading, transport, unloading, staging, and installation. PVC pipe must be protected from extended exposure to sunlight prior toinstallation. O.All water mains will be flushed and disinfected in strict accordance with the standard specifications of the Harnett Regional Water. All water samples collected for bacteria testing will be collected by the HRW Utility Construction Inspector and tested in the HRW Laboratory. P.All fittings larger than two (2”) inches diameter shall be ductile iron. HRW requires that mechanical joints be assembled with grip rings as “Megalug” fittings are not approved by Harnett Regional Water for pipe sizes smaller than twelve inches (12”) diameter. PVC pipe used for water mains shall be connected by slip joint or mechanical joint with grip rings. Glued pipe joints are not allowed on PVC pipe used for water mains in Harnett County. Q.HRW requires that the Utility Contractor install tracer wire in the trench with all water lines. The tracer wire shall be 12 ga. insulated, solid copper conductor and it shall be terminated at the top of the valve boxes or manholes. No spliced wire connections shall be made underground on tracer wire installed in Harnett County. The tracer wire may be secured with duct tape to the top of the pipe before backfilling. R.The Utility Contractor will provide Professional Engineer (PE) and the HRW Utility Construction Inspector with a set of red line field drawings to identify the installed locations of the water line(s) and all associated services. All change orders must be pre-approved by HRW and the Professional Engineer (PE) in writing and properly documented in the red line field drawings. S.The Utility Contractor shall spot dig to expose each utility pipe or line which may conflict with construction of proposed water line extensions well in advance to verify locations of the existing utilities. The Utility Contractor shall provide both horizontal and vertical clearances to the Professional Engineer (PE) to allow the PE to adjust the water line design in order to avoid conflicts with existing underground utilities. The Utility Contractor shall coordinate with the utility owner and be responsible for temporary relocation and/or securing existing utility poles, pipes, wires, cables, signs and/or utilities including services in accordance with the utility owner requirements during water line installation, grading and street construction. T.Prior to the commencement of any work within established utility easements or NCDOT right-of-ways the Utility Contractor is required to have a signed NCDOT encroachment agreement posted on site and notify all concerned utility companies in accordance with G.S. 87-102. The Utility Contractor must call the NC One Call Center at 811 or (800) 632-4949 to verify the location of existing utilities prior to the beginning of construction. Existing utilities shown in these plans are taken from maps furnished by various utility companies and have not been physically located or verified by the P.E. (i.e. TELEPHONE, CABLE, WATER, SEWER, ELECTRICAL POWER, FIBEROPTIC, NATURAL GAS, ETC.). The Utility Contractor will be responsible to repair any and all damages to the satisfaction of the related utility company. U.The Utility Contractor shall provide HRW with at least one (1) fire hydrant wrench and one (1) break-away flange kit for every subdivision with fire hydrants developed in Harnett County. These items must be provided to HRW before the final inspection will be scheduled by the HRW Utility Construction Inspector. In addition, the Utility Contractor shall install a 4” x 4” concrete valve marker at the edge of the right-of-way to identify the location of each gate valve installed in the new water system with the exception of the fire hydrant isolation valves. The contractor shall measure the distance from the center of the concrete marker to the center of the valve box. This distance (in linear feet) shall be stamped on the brass plate located on the top of the concrete valve marker. In lieu of installing the concrete valve markers, the Utility Contractor may provide at least two measurements from two independent permanent above ground structures to the Professional Engineer (PE) in the red line drawings to identify the valve locations. The Professional Engineer (PE) must include these measurements in the As-Built Record Drawings submitted to HRW. V.The Utility Contractor will be responsible for any and all repairs due to leakage damage from poor workmanship during the one (1)year warranty period once the water system improvements have been accepted by Harnett Regional Water. Harnett Regional Water will provide maintenance and repairs when requested and bill the Developer and/or Utility Contractor if necessary due to lack of response within 48 hours of notification of warranty work. The Utility Contractor will be responsible for any and all repairs due to damages resulting from failure to locate the new water lines and associated appurtenances for other utilities and their contractors until the water lines have been approved by NCDEQ and accepted by HRW. The final inspection of water system improvements cannot be scheduled with HRW until the streets have been paved; the rights-of-way and utility easements have been seeded and stabilized with an adequate stand of grass in place to prevent erosion issues on site. AA The Engineer of Record is responsible to ensure that construction is, at alltimes, in compliance with accepted sanitary engineering practices andapproved plans and specifications. No field changes to the approved plans areallowed without prior written approval by HRW. A copy of each engineer'sfield report is to be submitted to HRW as each such inspection is made onsystem improvements or testing is performed by the contractor. Water and sewer infrastructure must pass all tests required by HRW specifications and those of all applicable regulatory agencies. These tests include, but arenot limited to: air test, vacuum test, mandrel test, visual test, pressure test,bacteriological test, etc. A HRW Inspector must be present during testing andall test results shall be submitted to HRW. All tests must be satisfied beforethe final inspection will be scheduled with the HRW Inspector. The Engineerof Record must request in writing to schedule the final inspection once allconstruction is complete. The Developer's Engineer of Record and the HRWUtility Construction Inspector shall prepare a written punch list of any defectsor deficiencies noted during the final inspection, should any exist. Uponcompletion of the punch list, the Developer's Engineer of Record will scheduleanother inspection. In the event the number of inspections performed by the HRW exceeds two, additional fees may be assessed to the Developer. SANITARY SEWER A.The Professional Engineer (PE) shall obtain and supply a copy of the sewer permit for the construction and operation of the wastewater collection system to the Utility Contractor before the construction of the sanitary sewer line, sewer lift station and associated force main shall begin. The Utility Contractor must post a copy of the sewer permit issued by the North Carolina Department of Environmental Quality (NCDEQ) on site prior to the start of construction. The permit must be maintained on site during the construction of the sewer system improvements. B.The Utility Contractor shall notify Harnett Regional Water (HRW) and the Professional Engineer (PE) at least two days prior to construction commencing. The Utility Contractor must schedule a pre-construction conference with Mr. Chad Everette, HRW Utility Construction Inspector at least two (2) days before construction will begin and the Utility Contractor must coordinate with HRW for regular inspection visitations and acceptance of the wastewater system(s). Construction work shall be performed only during the normal working hours of HRW which is 8:00 am - 5:00 pm Monday through Friday. Holiday and weekend work is not permitted byHRW. C.The Professional Engineer (PE) shall provide HRW with a set of NCDEQ approved plans marked “Released for Construction” at least two days prior to construction commencing. HRW will stamp the approved plans as “Released for Construction” and provide copies to the utility contractor. The Registered Land Surveyor (RLS) shall stake out all lot corners and establish grade stakes for the proposed finish grade for each street and sewer line before the Utility Contractor begins constructionor installation of the manholes, sanitary sewer gravity line(s), sewer lift stations and/or sanitary sewer force main(s). The grade stakes should be set with a consistent offset from the street centerline so as not to interfere with the street grading or utility construction. D.The Utility Contractor shall provide the HRW Utility Construction Inspector with material submittals and shop drawings for all project materials prior to the construction of any gravity sewer line(s), manhole(s), sewer lift station(s) and associated force main(s) in Harnett County. The materials to be used on the project must meet the established specifications of HRW and be approved by the Engineer of Record prior to construction. All substandard materials or materials not approved for use in Harnett County found on the project site must be removed immediately when notified by the HRW Utility Construction Inspector. E.The sanitary sewer lateral connections should be installed 90° (perpendicular) to the sanitary sewer gravity lines with schedule 40 PVC pipe. HRW requires the Utility Contractor to provide the Professional Engineer (PE) with accurate measurements for locating sanitary sewer service lateral and associated each sanitary sewer clean-out. These measurements should be taken from the nearest downstream manhole up along the sanitary sewer main to the in-line wye fitting (or tapping saddle) and then another measurement from the in-line wye fitting (or tapping saddle)to the 4” x 4” long sweep combination wye fitting at the bottom of the sewer clean-out stack. These field measurements must be provided to the Professional Engineer (PE) in the red line drawings from the Utility Contractor for proper documentation in the As-Built Record Drawings submitted to HRW. F.The Utility Contractor shall be responsible to locate the newly installed sanitary sewer gravity line(s), sanitary sewer force main(s), sanitary sewer service lateral(s) and all associated sewer clean-out(s) in the proposed sanitary sewer system for other utility companies and their contractors until the new sanitary sewer line(s) and associated appurtenances have been approved by the North Carolina Department of Environmental Quality (NCDEQ) and accepted by HRW. All new sanitary sewer lines must have at least three (3 ft. ) feet of cover and extend under all existing water main and storm water lines with a least 24” of vertical clearance below the bottom of the existing water main and storm water lines. ALL ductile iron sewer piping must be 401 epoxy coated or approved equal. G.The sanitary sewer gravity line(s), manhole(s), sanitary sewer service lateral(s) and associated clean-out(s) shall be constructed in strict accordance with the standard specifications of the Harnett Regional Water. The sanitary sewer gravity line(s) must pneumatically pressure tested with compressed air at 5 psi and the sanitary sewer force main(s) must hydrostatically pressure tested with water or air at 200 psi. Sanitary sewer manholes must be vacuum tested to 10 inches of mercury and cannot drop below 9 inches in 60 seconds for 4 ft. diameter manholes, 75 seconds for 5 ft. diameter manholes. The test must be in accordance with the following standards: For ductile iron pipelines test in accordance with the applicable requirements of ASTM C924. For PVC pipelines test in accordance with ASTM F1417-98 and UBPPA UNI-B-6. Vacuum testing shall be performed in accordance with ASTM C1244 . The HRW Utility Construction Inspector and Engineer must witness all tests mentioned above. H.Prior to acceptance, all sewer service laterals will be inspected to ensure that they are installed at the proper depth. All sewer clean-outs must be installed so the 4” x 4” long sweep combination wye is at least three (3') feet but no more than four (4') feet below the finish grade unless otherwise approved in writing by HRW. The sewer cleanouts shall have a four (4”) schedule 40 PVC pipe stubbed up from both ends of the 4” x 4” long sweep combination wye to be at least two (2') feet above the finish grade and cover each end with a four (4”) inch temporary cap to keep out dirt, sand, rocks, water and construction debris. The vertical stack on each clean-out must be provided with a concrete donut for protection. I.Once the sanitary sewer gravity line(s) have been installed, pneumatically pressure tested and in place for at least 30 days, the Utility Contractor must contact the HRW Utility Construction Inspector to witness the mandrel test on each PVC sanitary sewer gravity line. The Utility Contractor will notify HRW to schedule the mandrel testing. The mandrel and proving ring must be supplied by the Utility Contractor. Closed circuit video camera inspections (at the Utility Contractor's expense) may be required by the HRW Utility Construction Inspector if the mandrel and mirror tamping testing cannot be completed with satisfactory results. The sanitary sewer lines should be flushed clean using a sewer ball of the proper diameter before any mandrel testing can be performed. The Utility Contractor is responsible to remove all dirt, sand, silt, gravel, mud and debris from the newly constructed sewer lines exercising care to keep the Harnett Regional Water's existing sanitary sewer systems clean. Sanitary sewer force main(s) shall be pressure tested to 200 psi for at least 2 hours like waterlines. J.The Utility Contractor shall be responsible to locate the newly installed sanitary sewer system(s) for other utility companies and their contractors until the new sanitary sewer system(s) have been approved by the North Carolina Department of Environmental Quality (NCDEQ) and accepted byHRW. K.HRW requires that the Utility Contractor install tracer wire in the trench with all sanitary sewer force mains. The tracer wire shall be 12 ga. insulated, solid copper conductor and it shall be terminated at the top of the valve boxes or manholes. No spliced wire connections shall be made underground on tracer wire installed in Harnett County. The tracer wire may be secured with duct tape to the top of the pipe before backfilling. The tracer wire is not required for the gravity sewer line(s) betweenmanholes. L.The Utility Contractor shall provide the Professional Engineer (PE) and HRW Utility Construction Inspector with a set of red line drawings identifying the complete sewer system installed for each project. The red line drawings should identify the materials, pipe sizes and approximate depths of the sewer lines as well as the installed locations of the manhole(s), sanitary sewer gravity line(s), sanitary sewer service laterals, clean-outs, sewer lift station(s) and associated force main(s). The red line drawings should clearly identify any deviations from the NCDEQ approved plans. All change orders must be approved by HRW and the Professional Engineer (PE) in writing and properly documented in the red line field drawings. M.Prior to the commencement of any work within established utility easements or NCDOT right-of-ways the Utility Contractor is required to notify all concerned utility companies in accordance with G.S. 87-102. The Utility Contractor must call the NC One Call Center at 811 or (800) 632-4949 to verify the location of existing utilities prior to the beginning of construction. Existing utilities shown in these plans are taken from maps furnished by various utility companies and have not been physically located by the P.E. (i.e. TELEPHONE, CABLE, WATER, SEWER, ELECTRICAL POWER, FIBER OPTIC, NATURAL GAS, ETC.). N.The Utility Contractor shall spot dig to expose each existing utility pipe or line which may conflict with construction of proposed sanitary sewer line extensions well in advance to verify locations of the existing utilities. The Utility Contractor shall provide both horizontal and vertical clearances to the Professional Engineer (PE) to allow the PE to adjust the sanitary sewer line design in order to avoid conflicts with existing underground utilities. The Utility Contractor shall coordinate with the utility owner and be responsible for temporary relocation of existing utilities and/or securing existing utility poles, pipes, wires, cables, signs and/or utilities including services in accordance with the utility owner's requirements during sanitary sewer line installation, grading and street construction. O.When making a tap on an existing sewer force main, the Utility Contractor must have a permit from the North Carolina Department of Environmental Quality (NCDEQ) prior to begin the tap work. The Utility Contractor shall conduct a pneumatic pressure test using compressed air or other inert gas on the stainless steel tapping sleeve and gate valve prior to making the tap on an existing sanitary sewer force main. This pneumatic pressure test must be witnessed by the HRW Utility Construction Inspector. The Utility Contractor shall use Romac brand stainless steel tapping sleeve(s) or approved equal for all taps made on sanitary sewer force mains in Harnett County. The Utility Contractor shall use Romac brand Style “CB” sewer saddles with stainless steel bands or approved equal for all taps made on existing sanitary sewer gravity lines in Harnett County. P.The Utility Contractor shall provide a grease trap for each sanitary sewer service lateral that will be connected to a restaurant, food processing facility and any other commercial or industrial facility as required by the Harnett County Fat, Oil & Grease Ordinance. The grease trap must be rated for a minimum capacity of at least 1,000 gallons unless otherwise approved in writing by the HRW Pre-Treatment Coordinator. Garbage disposals should not be installed in homes and businesses that discharge wastewater to the Harnett Regional Water's Sanitary Sewer System as they are not approved by HRW. Q.Each sewer lift station must be provided with three phase power (at least 480 volts) and constructed to meet the minimum requirements of the latest version of the National Electrical Code (NEC) and Harnett Regional Water standard specifications and details. If three phase power is not available from the power company other arrangements must be approved by HRW Engineering prior to the start of construction. R.Where a new sanitary sewer force main is connected to an existing manhole in the Harnett Regional Water sewer collections system, the Utility Contractor must provide a protective coating (epoxy) for the interior surfaces of the manhole to protect it against corrosion, erosion and deterioration from the release of sewer gases such as methane and hydrogen sulfide. S.The sewer lift station design and associated equipment must meet or exceed the MINIMUM REQUIREMENTS FOR HARNETT COUNTY SEWER LIFT STATIONS. Each sanitary sewer lift station must be constructed with an all-weather access road that is at least 20 feet wide. The lift station site must be covered with weed blocking material and at least six (6”) inches of ABC stone (crush and run). T.Once a sewer lift station has been installed, the Utility Contractor is responsible to schedule a draw down test with HRW Engineering and Collections staff, the Professional Engineer (PE), the Electrician, the original equipment manufacturers (OEM) representatives [For both the Pumps and the Generator]. This draw down test must be completed with power supplied from the electrical utility company and with power supplied by the emergency generator with satisfactory results before final inspections are conducted by the HRW Utility Construction Inspector. U.Once the Utility Contractor completes the installation of a sewer lift station, the Professional Engineer (PE) must submit the sewer permit certification and As-Built Record Drawings to the North Carolina Department of Environmental Quality (NCDEQ) and HRW for final approval. The Utility Contractor must supply HRW Engineering staff with three original Operation & Maintenance (O&M) Manuals along with the associated pump curves and electrical schematics for the associated sewer lift station equipment including all warranty information and documentation. V.Once the Utility Contractor completes the installation of a sewer lift station, the Developer must pay HRW the established System Control and Data Acquisition (SCADA) fees before the SCADA system will be installed at the new sewer lift station. The SCADA system must be installed and operational before the utilities may be accepted by HRW and placed into operation. W.HRW requires the Utility Contractor to provide all necessary equipment and devices for the testing and inspection of the sanitary sewer system. The equipment and devices may include but not limited to lamping with mirrors, mandrels, sewer balls, plugs, air compressors and associated compressed air lines. If the HRW Utility Construction Inspector deems that a closed circuit video camera inspection of the newly constructed sewer system is necessary, then all costs for the closed circuit camera inspection will be the responsibility of the Utility Contractor. All closed circuit video camera inspections must be recorded on VHS tapes that will released to HRW for record keeping, review and approval of the sewer system. X.Any use of sewer plugs to temporarily block Harnett Regional Water's existing sanitary sewer lines must be coordinated with the HRW Collections Supervisor at least two (2) days in advance of installing the plugs. The sewer plugs must be removed as soon as possible once the new sanitary sewer lines have been inspected, pressure tested, mandrel tested, approved by the North Carolina Department of Environmental Quality (NCDEQ) and accepted by HRW to allow the sewer to flow as designed in Harnett Regional Water's existing sanitary sewer lines or when so ordered by the HRW Collections Supervisor to limit interruptions to the normal flow of the sanitary sewer collection system(s). The Utility Contractor must provide the pumps hoses and necessary connectors for a temporary pump around setup if required by the HRW Collections Supervisor. Mr. Randolph Clegg, HRW Collections Supervisor may be contacted between 8:00 am and 5:00 pm Monday through Friday at (910)893-7575 extension 3241. Y.The Utility Contractor will be responsible for any and all repairs due to leakage or damage resulting from poor workmanship during the one (1) year warranty period once the sewer system improvements have been approved by the North Carolina Department of Environmental Quality (NCDEQ) and accepted by HRW. The Utility Contractor will be responsible for any and all repairs due to damages resulting from failure to locate the new sanitary sewer lines and associated appurtenances for other utilities and their contractors until the sanitary sewer lines have been approved by NCDEQ and accepted by HRW. HRW will provide maintenance and warranty repairs if necessary due to lack of response within 48 hours of notification of warranty work. HRW will invoice the Developer and/or Utility Contractor for materials and labor in such cases. Z.In developments and projects that require utility easements to be established for future HRW right-of-way, the Registered Land Surveyor (RLS) must provide the HRW Right-of-Way Agent with an official copy of the recorded plat and legal description of the said easement as recorded with the Harnett County Register of Deeds. The recorded documents must be provided to the HRW Right-of-Way Agent before the utility improvements within the said easement can be placed into operation. Any and all easements that must be obtained from adjoining property owners must be provided to HRW by the Developer at no cost to Harnett County. The final inspection of all sanitary sewer system improvements cannot be scheduled with HRW until the streets have been paved; the rights-of-way and utility easements have been seeded and stabilized with an adequate stand of grass in place to prevent erosion issues on site. AA.The Engineer of Record is responsible to ensure that construction is, at all times, in compliance with accepted sanitary engineering practices and approved plans and specifications. No field changes to the approved plans are allowed without prior written approval by HRW. A copy of each engineer's field report is to be submitted to HRW as each such inspection is made on system improvements or testing is performed by the contractor. Water and sewer infrastructure must pass all tests required by HRW specifications and those of all applicable regulatory agencies. These tests include, but are not limited to: air test, vacuum test, mandrel test, visual test, pressure test, bacteriological test, etc. A HRW Inspector must be present during testing and all test results shall be submitted to HRW. All tests must be satisfied before the final inspection will be scheduled with the HRW Inspector. The Engineer of Record must request in writing to schedule the final inspection once all construction is complete. The Developer's Engineer of Record and the HRW Utility Construction Inspector shall prepare a written punch list of any defects or deficiencies noted during the final inspection, should any exist. Upon completion of the punch list, the Developer's Engineer of Record will schedule another inspection. In the event the number of inspections performed by the HRW exceeds two, additional fees may be assessed to the Developer. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSANITARY SEWER DETAILSC4.6 TYPICAL SEWER SERVICE CONNECTION DETAIL 12" MIN.12" MIN. 8" MIN. 24" MIN. CLEARANCE TRENCH WALL UNIFORM STONE #57 UNDISTURBED SOIL D.I. SANITARYSEWER EXISTING STORM PIPE NOTE:1 EA. JOINT OF DUCTILE IRON PIPE SHALL BE CENTEREDUNDER STORM PIPE FOR ALL CROSSINGS. TYPICAL STORM SEWER CROSSING COPOLYMER POLYPROPYLENEPLASTIC M.A. INDUSTRIES MODEL PSI-PF OR APPROVED EQUAL. 918" 338"114" 118"918" 1034" 12"FLOWSLOPE 112":12"SLOPE11 2 ":12"USE 4 EA. 38" ANCHOR BOLTSTO BOLT FRAME TO SPACER.USE ROPE MASTIC SEALBETWEEN FRAME AND SPACER. STANDARD MANHOLERING AND COVER MANHOLE STEPS16" O.C. BRICK & MORTAR INVERT MIN. 6" GRAVEL BEDDING ECCENTRICTAPER UNIT RISER UNIT BASE UNIT 4' DIA. MIN.5" 2'-0", 3'-0"OR 4'-0" 8" MAX. FOR SPACER 8" JOINTS SHALL BE SEALEDWITH A RUBBER O-RINGGASKET OR ROPE MASTIC SEAL. CEMENT GROUT ALL JOINTSINSIDE AND OUT 112":12" SLOPEON ALL INVERTS EXTENDED BASE(REQUIRED OVER 12') TYPICAL STANDARD PRECAST CONCRETE MANHOLE DETAIL TYPICAL MANHOLE INVERT DETAIL 4" PVC VERTICAL 4" SWEEP WYE SERVICE LINE SANITARY SEWERMAIN TEE BRANCHSLOPE MIN. 1% PLUG STOP AT R/W 45°SANITARY TEE(SAME MATERIALAS MAIN) CLEANOUT PLUG AND CAP NOTE:EASEMENT SHALL BE PROVIDED FOR SERVICECONNECTION WHERE SERVICE CONNECTION IS PLACED OUTSIDE OF R/W DUE TO PHYSICAL CONSTRAINTS.CAST IRON VALVE BOXW/ CHARLOTTE HUB TYPICAL POLYPROPYLENE PLASTIC STEP DETAIL 3'-5' 1' insideRW NOTE: 1. THE FLOW CHANNEL THROUGH MANHOLES SHOULD BE MADETO CONFORM IN SHAPE AND SLOPE TO THE SEWER MAIN.2. CHANGE IN DIRECTION OF THE CHANNEL SHALL NOT BE EXCEED 90 DEGREES. NOTE:1. PIPE SIZE FOR DROP TO EQUALINFLOW SEWER PIPE SIZE. 2. FITTINGS FOR DROPS SHALL BE C-900OR SCHEDULE 40 PVC. 3. SAW-CUT OR DRILL ALL HOLES FORPIPE AND BOLTS.4. DROP-MANHOLE MANDATORY WHEN DIFFERENTIAL BETWEEN INVERTS ISGREATER THAN 24". STANDARD MANHOLERING & COVER STANDARD PRECAST MANHOLE 5'-0" MIN. DIA. TEEPLUGOR CAP 14"x 2" S.S. PIPESUPPORTS 90° BEND TYPE 316 S.S.EXPANSION ANCHORS RUBBER BOOT RUBBER BOOT MANHOLE STEPS GROUTTO SLOPE TYPICAL INSIDE DROP MANHOLE DETAIL NOTE:IN NON-TRAFFIC AREAS,TOP OF FRAME AND COVER SHALL BEINSTALLED AT LEAST 2 FT ABOVE FINISH GRADE OR AT LEAST 1 FT ABOVE FLOOD STAGE. SEE DETAIL S-25 1. SEE DETAIL S-28 FOR TYPICAL INVERT. NOTES: SEE DETAIL S-25 3. SEE DETAIL S-24 FOR TYPICAL MANHOLE STRUCTURE. IN-LINE WYEFITTING FOR NEWCONSTRUCTION OR ROMAC-CB SADDLEFOR TAP ON EXISTINGSANITARY SEWER MAIN. BRASS FOR SANITARY SEWER DETAIL WIDTH ASREQUIRED 12" MIN. 12" MIN.12" MIN. 8" MIN. 24" MIN. CLEARANCE TRENCH WALL UNIFORM STONE #57 UNDISTURBED SOIL D.I. SANITARY SEWER EXISTING WATER LINE TYPICAL WATER LINE CROSSING FOR SANITARY SEWER DETAIL 5. SEE DETAIL S-28 FOR TYPICAL INVERT (DO NOT GLUE) SCH 40 PVC VERTICAL SCH 40 PVC SCH 40 PVC NOTE:1 EA. JOINT OF DUCTILE IRON PIPE SHALL BE CENTERED UNDER WATER LINE FOR ALL CROSSINGS. RUBBER BOOT GROUT TOSLOPERUBBER BOOT H*=6" OR LESS RUBBER BOOT RUBBER BOOT BUILD SMALLRAMP 12 H* H*= 6" - 24" SLIDER PIPE MANHOLE DETAIL IF "H" IS BETWEEN 6" - 24" IF "H" IS BETWEEN 6" OR LESS*H = ELEVATION DIFFERENCE BETWEEN INVERT OFEFFLUENT PIPE AND INVERT OF INFLUENT PIPE. STANDARD PRECASEMANHOLE STANDARD PRECASEMANHOLE Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSANITARY SEWER DETAILSC4.7 COVER FRAME & COVER FRAME NOTE: CONCRETE ENCASEMENT SHALL ONLY BEUSED IN AREAS WHERE COVER IS TO BE FLUSHWITH PAVEMENT OR CONCRETE. CONCRETEENCASEMENT SHALL NOT BE USED IN NON-TRAFFIC AREAS AND ABOVE GRADEINSTALLATIONS. USE MIN. 4 EA. 3/8" ANCHOR BOLTS TO SECURE FRAME TO MANHOLE 23.5" RAM-NEKSEALANT 2"1" BASE COURSEBASE COURSE FINISHED GRADE 1.5" MIN. 6" MIN. COMPACTED FILLCOMPACTED FILL STD. MANHOLERING & COVER SANITARY SEWER (0'-8' DEPTH) PIPE LAYING CONDITION "A" PIPEO.D. HAND PLACED DENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPE BEDDED PIPE MINIMUM STONEEMBEDMENT ASINDICATED. GREATER IF REQUIRED BYMANUFACTURER 12 PIPEO.D.24" + O.D. MAX.12" + O.D. MIN. D/8≥3"D/4 D/2D/8≥3" 24" + O.D. MAX.12" + O.D. MIN. 12 PIPEO.D. MINIMUM STONEEMBEDMENT AS INDICATED. GREATER IFREQUIRED BYMANUFACTURER BEDDED PIPE HAND PLACEDDENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPE PIPEO.D. SANITARY SEWER(<8'-16' DEPTH)PIPE LAYING CONDITION "B" SHAPED STONETO PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARREL SHAPED STONE TO PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARREL SANITARY SEWER (DUCTILE IRON ONLY) (0'-16' DEPTH)PIPE LAYINGCONDITION "C" PIPEO.D. HAND PLACEDDENSELY COMPACTED BACKFILL TO 1 FT.ABOVE TOP OF PIPE BEDDED PIPE 12 PIPEO.D.24" + O.D. MAX.12" + O.D. MIN. D/2D/8≥3" 24" + O.D. MAX.12" + O.D. MIN. 12 PIPEO.D. MINIMUM STONEEMBEDMENT AS INDICATED. GREATER IF REQUIRED BYMANUFACTURER BEDDED PIPE HAND PLACED DENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPE PIPEO.D. SANITARY SEWER (DUCTILE IRON ONLY) (>16' DEPTH) PIPE LAYING CONDITION "D" SHAPED SUBGRADETO PROVIDE BEARING ALONG ENTIRE LENGTHOF PIPE BARREL SHAPED STONE TO PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARREL NOTE: FORCE MAINS 8"Ø AND SMALLER SHALLHAVE MINIMUM OF 3' COVER. FORCEMAINS LARGER THAN 8"Ø SHALL HAVE A MINIMUM OF 3'-6" COVER. ELECTRONIC MARKER BALLS AT 100' ONCENTER & AT BENDS. MARKER BALLS SHALLBE INSTALLED AT 1 1/2 TO 2' DEEP. 1/2 PIPE O.D. 24" + O.D. MAX.12" + O.D. MIN. PIPEO.D. SHAPED SUBGRADESHALL PROVIDE BEARING ALONG ENTIRE LENGTHOF PIPE BARREL BEDDED PIPE UNDISTURBED EARTH NOTE: MARKER BALLS SHALL BE INSTALLEDCONCURRENTLY WITH PIPE. MARKERBALLS SHALL NOT BE INSTALLED AFTER TRENCH HAS BEEN COMPLETELY BACKFILLED. HAND PLACEDDENSELY COMPACTED BACKFILL TO 1 FT.ABOVE TOP OF PIPE FORCE MAIN PIPE LAYING CONDITION "E" NOTE: PIPE SHALL BE BEDDED UP TOSPRING LINE AND MINIMUM 4" BELOWBOTTOM OF PIPE WHEN WET AREAS ARE ENCOUNTERED. TYPICAL PIPE LAYING CONDITION DETAIL TYPICAL PIPE LAYING CONDITION DETAIL TYPICAL PIPE LAYING CONDITION DETAILS FRAME & COVER DETAIL TYPICAL STANDARD MANHOLE Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONWATER DETAILSC4.8 METER SETTERCENTEREDIN BOX 18" MIMINUM COVERTYPICAL 3/4" METER SETTER INSTALLATION DETAIL METER SETTER WITHDOUBLE CHECK VALVE(BACKFLOW PREVENTER) METER BOX LID, CAST IRON 1' FROM EDGE OF ROW SERVICE LINEFROM STREET 1. METER AND PRIVATE SERVICE LINE NOT IN CONTRACT UNLESS SPECIFIED 2. INCLUDE STONE IN PRICE OF METER BOX. 3. METER SETTER SIZE AS NOTED ON PLANS. 4. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE. 3/4" X 18"BRASS NIPPLERWPROPERTY METER TO BE INSTALLED BRICK SUPPORT 9" VALVE BOX24"x18" RECTANGULAR 17" 18" 24" 3 1/2" 18" 12" A BA ELEVATION ISOMETRIC PLAN NO SCALE TYPICAL METER BOX DETAIL FOR 3/4" SERVICE CAST IRON 16 3/4" 11"SIGMAWATERMETER ABS PLASTIC CONDITIONSLAYING DESCRIPTION PROJECT USE PIPE BEDDED IN 4" MININUM JOB EXCAVATED MATERIAL. BACKFILL LIGHTLY CONSOLIDATED TO TOP OF PIPE. PIPE BEDDED IN SAND, GRANULAR MATERIAL OR GRADED GRAVEL TO THE DEPTH OF 1/8 PIPE DIAMETER, 4" MIN. JOB EXCAVATED MATERIAL COMPACTED TO 4" ABOVE TOP OF PIPE. (APPROX. 95% STANDARD PROCTOR, AASHTO T-99) ALL DUCTILE IRON GRAVITY SEWER LINE. ALL PVC WATER LINE AND PVC FORCE MAIN. TYPE 3 TYPE 4 NO SCALE TYPICAL LAYING CONDITIONS DETAIL NOTE: ALL GATE VALVES SHALL BE PLACEDON AN 80 LB. BAG OF SACRETE. RESTRAINTJOINT 90° BENDS CAST IRONVALVE BOX TAPPINGVALVE 24"x24"x6" THICKCONCRETE PADCAST IN PLACEOR PRE-CAST 1/2" ALTERNATE TAPPING SLEEVE AND VALVE DETAIL NOT TO SCALE NO SCALE TYPICAL THRUST BLOCK DETAIL ADJUSTABLEVALVE BOX BRICK TOSUPPORTVALVE BOX MECHANICAL JOINTWITH GRIP RING 36" THREADED BRASSPIPE NIPPLE 2" DIA CONCRETE BLOCKINGMIN. 1/3 C.Y. AT 3000 P.S.I. PRECAST CONCRETEPROTECTION RING SQUARE HEAD VALVE NUT ONLY MIN 1/5" OF PROTECTIONRING TO BE EXPOSED TAMPED BACKFILL THREADEDCOUPLING WATER MAIN 2" 1" BACKFILL TO EDGE FINISHED GRADE MIN 6" MIN OF 24" THREADEDBRASS PIPE NIPPLE 2" DIAOR LONGER TO BRING PIPEUP TO FINISHED GRADE2" BRASSTHREADEDPIPE NIPPLE MIN 18" END CAP ON PLUGWITH 2" THREADED PORT NOTE: SEE TYPICAL VALVE BOX DETAIL FOR BRICK INSTALLATION NO SCALE TYPICAL PERMANENT BLOW-OFF ASSEMBLY DETAIL Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONWATER DETAILSC4.9 CENTER LINE CARRIER PIPE SPIDERS SUPPORT CARRIER PIPE IN CASING STEEL CASING PIPE 2" BEVEL 2" WEEP HOLE SLOPE TO DRAIN ENCLOS ENDS WITH8" BRICK MASONRY GRAVEL 3'-0" ELEVATION TRANSITION FITTING AS REQUIRED BRICK CLOSURE ST'L. CASING PIPE DUCTILE IRONPIPE CARRIER 3'-0" MIN. COVER OR AS SHOWNON THE PLANS. PAVEMENT (ONE OR TWOLANES) RAILROAD 5'-6" MIN. COVEROR AS SHOWN ONTHE PLANS PROFILE NO SCALE TYPICAL BORING & JACKING DETAIL ON THE THRUST BLOCKING SCHEDULE.5. VOLUME OF THRUST BLOCKING SHALL BE AS SHOWN BLOCKING. WITH 10 MIL. POLYETHYLENE PRIOR TO POURING4. ALL PIPING AND ACCESSORIES TO BE WRAPPED3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS. PART (BLOCKING AREA) AGAINST UNDISTURBED SOIL. SHAPE MORE EASILY FORMED WITH THE WIDEST FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT1. CONCRETE SHALL BE 3,000 PSI MIN.NOTES: 12" 10" 8" 6" 8" 6" 8" 6" 8" 6" 8"8" 36" 34" 30" 25" 24" 18" 16" 20" 18" 16" 14" 12" 12" 10" 20" 18" 16" 14" 12" 10" 9" 18" 16" 14" 11" 10" 10" 8" 16" 14" 12" 10" 8" 6" 12" 10" 8" 6" 16" 14" 12" 10" 8"8" 18" 16" 14" 12" 10" 10" 8" 16" 14" 12" 10" 10" 8" 8" 20" 18" 16" 14" 13" 12" 12" 26" 22" 20" 16" 15" 10" 8" 16" 14" 12" 10" 8" 6" 4" C D A B A B A B A B A B PLUGTEE11/4° BEND221/2° BEND45° BEND90° BENDSIZEPIPE 24" MIN. - 12" OR LESS18" MIN. - 10" OR LESS 18" MIN.SQDSQCBB45° 2 1/2" HOSECONNECTION STEAMERCONNECTION CONC. ON PLANS AS SHOWN BLOCKING(SEE NOTE) WEEP HOLE TOREMAIN OPEN BACKFILL STONE(7 C.F. MIN.) 6" G.V. &C. I. BOX 4-3/4" TIE RODS WITH BRACKETS (SEE DETAIL)6" HYDRANT TEE 6" WATERLINE NOTE: 1.)TIE HYDRANT TO MAIN LINE W/TIE RODS IN LIEW OF CONC. BLOCKING IN SANDY SOIL. PRECAST CONCRETEPROTECTION RING NO SCALE TYPICAL FIRE HYDRANT INSTALLATION DETAIL EDGE OFROAD ON THE THRUST BLOCKING SCHEDULE.5. VOLUME OF THRUST BLOCKING SHALL BE AS SHOWN BLOCKING. WITH 10 MIL. POLYETHYLENE PRIOR TO POURING4. ALL PIPING AND ACCESSORIES TO BE WRAPPED3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS. PART (BLOCKING AREA) AGAINST UNDISTURBED SOIL. SHAPE MORE EASILY FORMED WITH THE WIDEST FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT1. CONCRETE SHALL BE 3,000 PSI MIN.NOTES: 12" 10" 8" 6" 8" 6" 8" 6" 8" 6" 8"8" 36" 34" 30" 25" 24" 18" 16" 20" 18" 16" 14" 12" 12" 10" 20" 18" 16" 14" 12" 10" 9" 18" 16" 14" 11" 10" 10" 8" 16" 14" 12" 10" 8" 6" 12" 10" 8" 6" 16" 14" 12" 10" 8"8" 18" 16" 14" 12" 10" 10" 8" 16" 14" 12" 10" 10" 8" 8" 20" 18" 16" 14" 13" 12" 12" 26" 22" 20" 16" 15" 10" 8" 16" 14" 12" 10" 8" 6" 4" C D A B A B A B A B A B PLUGTEE11/4° BEND221/2° BEND45° BEND90° BENDSIZEPIPE 24" MIN. - 12" OR LESS18" MIN. - 10" OR LESS 18" MIN.SQDSQCBB45° PLAN TEESHYDRANT TEE PLAN BENDS X X 6" MIN. AA X X AA 6" MIN. NO SCALE TYPICAL THRUST BLOCK DETAIL SECTION "A" BOLTS TO PIPE STEEL SKIDS (4) HEAVY DUTY INNER PIPE.) SIZE OF STEEL CASING AND(SPIDER SIZE DETERMINED BY CARRIER PIPE 3/4" CHAMFER ATEA. CORNER 4" SQ. PRECAST CONC.POST (4000 P.S.I.) BRASS MARKER PLATE VALVE NO. 120 25 FT. PLATE WITH VALVE NUMBER,DIRECTIONAL ARROW-POINTEDTO MARKED VALVE & DISTANCETO THE NEAREST FOOT. MARKED PLATEWITH ANCHOR 4 #3 BARS NO SCALE TYPICAL VALVE MARKER DETAIL VM CAST THE LETTERS "MV" INONE FACE OF THE CONCRETEMARKER AND ORIENT TOWARDTHE ROADWAY BOROTATE MARKER TO OTHER ENDFOR BLOW-OFF 2" 1" FINISHED GRADE VALVE BOX VALVE OPERATOR NUT NO SCALE TYPICAL VALVE BOX DETAIL PROTECTION RING PRECAST CONCRETE BACKFILL TO EDGE NOTE:AT PIPE INTERSECTIONS, MULTIPLEVALVES, RUN WIRE UP AT ONLY ONE VALVE. SINGLE 12 AWG SOLID CORE WIRE GATE VALVE TRACER WIRE TO BE LAIDUNDERNEATH WATER LINE VALVE BOX FINISHED GRADE IN VALVE BOX NO. 1DRILL HOLE FOR TRACER WIRE TRACER WIRE VALVE BOX P.V.C. PIPELINE NOTES:1. DRILL HOLE IN VALVE BOX TO INSERT TRACER WIRE,BRING UP TO INSIDE AND ROLL UP AT LEAST 6"-8" EXCESS VALVE BOX 2. PLACE TRACER WIRE IN VALVE BOX AT 1,000 FT INTERVALS OR AS NOTED ON THE PLANS, TYPICAL. PLACE EMPTY VALVE BOX AT INTERVALS WHERE VALVES DO NOT OCCUR & PLACE TRACER WIREIN BOX. NO SCALE TYPICAL TRACER WIRE INSTALLATION DETAIL 3. DO NOT SPLICE WIRE WHEN BEGINNING A NEW SPOOL. INSTEAD INSTALL A VALVE BOX AND ATTACH EACH WIRE WITH A BRASS SCREW TO THE VALVE BOX. NOTE: LOOPED IN BOX6"-8" EXCESS PRECAST CONCRETE PROTECTION RING BACKFILL TO EDGE WATERMAIN STREET PROPERTYLINEPROPERTYLINER/W R/W NO SCALE TYPICAL DOMESTIC WATER SERVICE INSTALLATION DETAIL SINGLE 3/4" SERVICES 2" PVC SLEEVE W/ 3/4" CARRIER 12" MIN 5. SEE DETAIL FOR SERVICE MATERIAL AND METER SETTING 4. SLEEVES SHOULD BE SCHEDULE 40 PVC PIPE. INSIDE A 3" SLEEVE."OPEN1' 6. SERVICE LINE SHALL BE 3' BELOW FINISHED GRADE OF DITCHES. 6' METERS SHOULD BE INSTALLED 3' OFF PROPERTY LINE EXISTING WATER MAIN NEW WATER MAIN TAPPING VALVEWITH VALVE BOX NO SCALE TYPICAL TAPPING SLEEVE AND VALVE ASSEMBLY DETAIL TAPPING SLEEVE SHALL BE ROMAC BRAND MODEL SST MANUFACTURED WITH 316 STAINLESS STEEL. PAINT MARKER BLUE AFTER INSTALLATIONNOTES: PE PLASTIC TO PROTECTTAPPING SLEEVE THRUST BLOCKING 7. CONDUIT MUST EXTEND PAST PREPOSED SIDEWALK. SIDEWALK MASONRY BLOCK MASONRY BLOCK 2.)MECHANICAL JOINTS USED WITH GRIP RINGS A NOTE: ALL GATE VALVES SHALL BE PLACEDON AN 80 LB. BAG OF SACRETE. RESTRAINTJOINT 90° BENDS CAST IRONVALVE BOX TAPPINGVALVE 24"x24"x6" THICKCONCRETE PADCAST IN PLACEOR PRE-CAST 1/2" ALTERNATE TAPPING SLEEVE AND VALVE DETAIL TAPPINGSLEEVE NO SCALE W W W W W W WW W W SSSS1 4 10 31 30 29282726252423 SS SS SS SS SS SS SS SS SS SS SS SS SS 22 WW W WC2L4OHUC3TIEN 02°18'21" E30.00'6+004+504+002+502+00 5+00 5+500+50 3+00 3+50 CURVE 2A= 298.46'R= 230.00'ΔD= 74°20'56"WLC= 277.95'DOC= 24°54'40" CURVE 1A= 39.16'R= 230.00'ΔD= 9°45'23"C= 39.12'DOC= 24°54'40"0+000+500+000+50NOTE:FIELD VERIFY EXISTING EOPELEVATION. ASSURE THATPROPOSED ROAD HIGH POINT IS HIGHERTHAN EXISTING EDGE OF PAVEMENT TOPREVENT OFF SITE DRAINAGE ONTOPROPOSE ROAD HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)0+00 1+00 1+50 PC =6+17.30Rad =230.00'6+50 PT =6+56.46PC =6+56.46Rad =230.00'7+00 7+5 0 8+ 0 0 HP =0+36.91EL = 172.60'LP =2+52.79EL = 169.85'HP =3+23.48EL = 170.11'LP =4+51.76EL = 168.34'HP =5+95.81EL = 169.25' LP =7+ 1 5 . 8 0EL = 1 6 8 . 7 4 ' HP = 7 + 9 2 . 6 9 EL = 1 6 9 . 1 6 'EL = 169.33'LP =0+51.58EL = 168.80'LP =0+41.005.0' CONC.SIDEWALK (TYP.) R30.0' R30.0' R30.0' R30.0' 24.0'EOP-EOP50.0'ROW 10' X 70' SDT(BOTH SIDES) EX. 16" WL SANITARYSEWER MAIN CL INTERSECTIONSTA. 0+00N: 548090.24E: 2025296.07 STOP SIGN WATER SERVICE(TYP.) SEWER SERVICE(TYP) CL INTERSECTIONMAIN RD STA = 2+03.64STUB RD SOUTH STA = 0+00 CL INTERSECTIONMAIN RD STA = 5+96.42STUB RD NORTH STA = 0+00 ADA RAMP ANDCROSSWALK -SEE CURB RAMPDETAIL (TYP.) ADA RAMP ANDCROSSWALK -SEE CURB RAMPDETAIL (TYP.) CL STA 1+69.0017.55' RTFIRE HYDRANTASSEMBLY CL STA 5+41,18.95' RTFIRE HYDRANTASSEMBLY 30" ROLLEDCURB AND GUTTER(TYP.) TIE 6" WL PVC WATER MAINEX. 6" WL WATER LINE EX 16" WL SANITARYSEWER MAIN PROPERTYBOUNDARY CI-28 CI-12 CI-11 CI-27 CI-10 CI-9 CI-8 CI-7 CI-6 CI-26 CI-5 CI-13CI-18 SMH-3 SMH-4 SMH-2SMH-1 SM H - 4 BORE UNDER ROAD ADA RAMP ANDCROSSWALK -SEE CURB RAMPDETAIL (TYP.)SMH-90+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 STA =2+03.64Stub Rd-SouthEL = 170.03STA =5+96.42Stub Rd-NorthEL = 169.25PVI STA. 0+12.00PVI ELEV. 172.49'PVI STA. 0+55.37PVI ELEV. 172.71'PVC STA. 0+30.37PVC ELEV. 172.58'CREST STA. 0+36.91CREST ELEV. 172.60'PVT STA. 0+80.37PVT ELEV. 171.88'50.00' VCAD-3.8313.07' K-Val PVI STA. 1+23.91PVI ELEV. 170.43'PVC STA. 0+98.91PVC ELEV. 171.26'PVT STA. 1+48.91PVT ELEV. 170.30'50.00' VCAD2.8317.69' K-Val PVI STA. 2+52.79PVI ELEV. 169.78'PVC STA. 2+27.79PVC ELEV. 169.91'SAG STA. 2+52.79SAG ELEV. 169.85'PVT STA. 2+77.79PVT ELEV. 169.91'50.00' VCAD1.0050.00' K-Val PVI STA. 3+38.35PVI ELEV. 170.21'PVC STA. 3+13.35PVC ELEV. 170.09'CREST STA. 3+23.48CREST ELEV. 170.11'PVT STA. 3+63.35PVT ELEV. 169.72'50.00' VCAD-2.4720.27' K-Val PVI STA. 4+40.56PVI ELEV. 168.20'PVC STA. 4+15.56PVC ELEV. 168.69'SAG STA. 4+51.76SAG ELEV. 168.34'PVT STA. 4+65.56PVT ELEV. 168.39'50.00' VCAD2.7218.40' K-Val PVI STA. 5+90.80PVI ELEV. 169.33'PVC STA. 5+65.80PVC ELEV. 169.14'CREST STA. 5+95.81CREST ELEV. 169.25'PVT STA. 6+15.80PVT ELEV. 169.20'50.00' VCAD-1.2540.00' K-Val PVI STA. 7+24.13PVI ELEV. 168.66'PVC STA. 6+99.13PVC ELEV. 168.79'SAG STA. 7+15.80SAG ELEV. 168.74'PVT STA. 7+49.13PVT ELEV. 168.91'50.00' VCAD1.5033.33' K-Val PVI STA. 7+81.09PVI ELEV. 169.23'PVC STA. 7+56.09PVC ELEV. 168.98'CREST STA. 7+92.69CREST ELEV. 169.16' 50.00' VCAD-1.3736.60' K-Val CL STA =1+97.298" SDR-26 PVCINV = ±158.6'CL STA =6+02.368" SDR-26 PVCINV = ±158.6'24" RCP 30" RCP CL STA =2+52.7915" RCPINV = ±166.6'CL STA =4+51.7615" RCPINV = ±165.1'CL STA =7+16.3815" RCPINV = ±165.5'24" RCP 24" RCP 30" RCP 30" RCP 30" RCPCI-6SMH-4CI-8SMH-3CI-7CI-9CI-10CI-11SMH-2CI-12SMH-1PROPOSEDGRADE EXISTING GRADE 6" WL C-900PVC WATERLINE 8" SDR-26 PVCSANITARY SEWER MAIN 6" WL C-900 PVC WATERLINE Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSCALE IN FEET 0'15 30 60 NORTH BLACK FOREST DRIVE SCALE: HORIZ. 1"=30' VERT. 1"=5' SCALE: 1"=30'MATCHLINE STA. 7+75 (SEE SHEET C5.1)MATCHLINE STA. 7+75 (SEE SHEET C 5.1)ROADWAY PLAN AND PROFILEC5.0 NCDOT STANDARD NOTES: 1. ALL UTILITY STRUCTURES SHALL BE LOAD RATED FOR THE APPROPRIATE DEADLOAD PLUS HL-93 LIVE LOAD. SUCH STRUCTURES SHALL BE DESIGNATED ANDCERTIFIED BY A LICENSED PE OR DESIGNATED AS MEETING NCDOT STANDARDSPECIFICATIONS AND DRAWINGS. 2. ELECTRICAL POWER AND COMMUNICATIONS FACILITIES SHOULD CONFORM TOTHE CURRENTLY APPLICABLE NATIONAL ELECTRICAL SAFETY CODE EXCEPT VERTICALCLEARANCES SHALL BE NO LESS THAN 18 FEET IN ANY CASE. 3. ALL NON-FERROUS PIPELINES SHALL BE INSTALLED WITH A LOCATING TAPE. 4. ANY SUBDIVISION MARKER WILL NEED TO BE LOCATED OUTSIDE OF RIGHT OFWAY. NOTE: STORM DRAINAGE RIM ELEVATION ISREFERENCED FROM EDGE OF PAVEMENT FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT. STORM DRAINAGE PROFILE AND PIPE DATASEE OVERALL STORM DRAINAGE PLAN ANDSTORM DRAINAGE PROFILE SHEETS SANITARY SEWER AND WATER MAIN DATA -SEE SANITARY SEWER AND WATER MAINPLAN AND PROFILE SHEETS (PUBLIC & UTILITY R/W)BLACK FOREST DRIVE CI-6 168.38 161.34 165.35 161.24 CI-7 168.70 161.58 N/A 161.48 CI-8 168.44 161.77 N/A 161.67 CI-9 168.44 162.32 162.32 161.82 CI-10 168.66 162.51 N/A 162.41 CI-11 167.97 162.81 164.95 162.71 CI-12 169.48 163.30 166.45 163.20 CI-13 168.97 166.00 163.91 163.41 CI-18 168.97 N/A N/A 166.22 CI-28 169.48 N/A N/A 166.73 CI-27 167.97 N/A N/A 165.22 CI-26 168.38 N/A N/A 165.63 DRAINAGE STRUCTURESNAME RIM / EOP INV. IN (1) INV. IN (2) INV. OUT 16171819SS SS SS33 70 . 0 0 '343536W W W W W W15616015816816716616516416316216161 7 . 2 3 ' CURVE 1A= 298.46'R= 230.00'ΔD= 74°20'56"WLC= 277.95'DOC= 24°54'40" 2+ 0 0 8+00 8+50 9+00 9+ 5 0 PT =9+54.92HP =7+92.69EL = 169.16'LP =0+54.28EL = 168.14'HP =1+01.32EL = 168.91'EL = 1 6 8 . 1 1 ' LP = 1 + 5 9 . 6 5 5.0' CONC.SIDEWALK (TYP.) R35.0'EOP R45.0'ROW 20' DRN & ACCESSEASEMENT R17.0'(TYP) SEE CUL DE SACPLAN AND PROFILETHIS SHEET CI-5 CI-3 CI-25 CB-2 SMH-4 SEWERSERVICE (TYP) CI-4 4.0' x 4.0' CONC. PAD FORMAIL KIOSK CI-29 POND MAINTENANCEEASEMENT - SEE POND DETAIL,SHEET C-8.0 FOR FULLEASEMENT DIMENSIONS SMH-5 CL STA 8+72,22.0' RTFIRE HYDRANTASSEMBLY PROPOSED STREELIGHT (TYP.) 8" P V C S A N I T A R Y SE W E R M A I N SSSS35WWWW9+009+50PT =9+54.92 0+000+501+00 1+502+ 0 0 2+17.70LP =0+54.28EL = 168.14'HP =1+01.32EL = 168.91'168.76168.40168.40EL = 168.11'LP =1+59.658+509+009+36.21R35.0' R17.0' R45.0'(ROW) 4' X 4' CONC.PAD FOR MAILKIOSK 0+00 1+00 1+50 2+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 PVI STA. 0+57.33PVI ELEV. 168.12'PVC STA. 0+52.33PVC ELEV. 168.14'SAG STA. 0+54.28SAG ELEV. 168.14'PVT STA. 0+62.33PVT ELEV. 168.22'10.00' VCAD2.573.89' K-Val PVI STA. 1+00.00PVI ELEV. 169.00'PVC STA. 0+90.00PVC ELEV. 168.79'CREST STA. 1+01.32CREST ELEV. 168.91'PVT STA. 1+10.00PVT ELEV. 168.84'20.00' VC AD-3.665.47' K-Val PVI STA. 1+57.08PVI ELEV. 168.09'PVC STA. 1+52.08PVC ELEV. 168.17'SAG STA. 1+59.65SAG ELEV. 168.11'PVT STA. 1+62.08PVT ELEV. 168.12'10.00' VCAD2.104.77' K-Val 0+50CL STA =0+40.4630" RCPINV = ±160.6'CL STA =0+48.1930" RCPINV = ±160.6'PROPOSEDGRADE EXISTINGGRADE 7+50 8+00 8+50 9+00 9+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 PVT ELEV. 168.91'PVI STA. 7+81.09PVI ELEV. 169.23'PVC STA. 7+56.09PVC ELEV. 168.98'CREST STA. 7+92.69CREST ELEV. 169.16'PVT STA. 8+06.09PVT ELEV. 169.14'50.00' VCAD-1.3736.60' K-Val 36" RCP 30" RCP 36" RCP CL STA =8+78.6515" RCPINV = ±165.3'CI-4SMH-6SMH-5CI-5PROPOSEDGRADE EXISTING GRADE 8" SDR-26 PVCSANITARY SEWER MAIN 6" WL C-900 PVC WATERLINE Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSCALE IN FEET 0'15 30 60NORTH BLACK FOREST DRIVE SCALE: HORIZ. 1"=30' VERT. 1"=5' CUL DE SAC EOP PLAN VIEW SCALE: 1"=30'ROADWAY PLAN AND PROFILEC5.1MATCHLINE STA. 7+75 (SEE SHEET C5.0 )MATCHLINE STA. 7+75 (SEE SHEET C5.0)CUL DE SAC EOP PROFILE SCALE: HORIZ. 1"=30' VERT. 1"=5' NOTE: STORM DRAINAGE RIM ELEVATION ISREFERENCED FROM EDGE OF PAVEMENT FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT. NCDOT STANDARD NOTES: 1. ALL UTILITY STRUCTURES SHALL BE LOAD RATED FOR THE APPROPRIATE DEADLOAD PLUS HL-93 LIVE LOAD. SUCH STRUCTURES SHALL BE DESIGNATED ANDCERTIFIED BY A LICENSED PE OR DESIGNATED AS MEETING NCDOT STANDARDSPECIFICATIONS AND DRAWINGS. 2. ELECTRICAL POWER AND COMMUNICATIONS FACILITIES SHOULD CONFORM TOTHE CURRENTLY APPLICABLE NATIONAL ELECTRICAL SAFETY CODE EXCEPT VERTICALCLEARANCES SHALL BE NO LESS THAN 18 FEET IN ANY CASE. 3. ALL NON-FERROUS PIPELINES SHALL BE INSTALLED WITH A LOCATING TAPE. 4. ANY SUBDIVISION MARKER WILL NEED TO BE LOCATED OUTSIDE OF RIGHT OFWAY. SCALE: 1"=30' (PUBLIC & UTILITY R/W)BLACK FOREST DRIVE CB-2 168.00 159.75 N/A 159.65 CI-3 168.13 163.14 160.59 160.09 CI-29 168.11 N/A N/A 165.36 CI-4 168.51 160.84 165.24 160.74 CI-5 168.79 161.11 N/A 161.01CI-25 168.51 N/A N/A 165.86 DRAINAGE STRUCTURES NAME RIM / EOP INV. IN (1) INV. IN (2) INV. OUT OUTFALL - 159.56 N/A N/A STORM DRAINAGE PROFILE AND PIPE DATASEE OVERALL STORM DRAINAGE PLAN ANDSTORM DRAINAGE PROFILE SHEETS SANITARY SEWER AND WATER MAIN DATA -SEE SANITARY SEWER AND WATER MAINPLAN AND PROFILE SHEETS WWW W W W W W W W WSS SS SS SS SS SS SS 123456789252423SSSSSSSSSS22OHUEXISTING 40' UTILITY EASEMENT20' EITHER SIDE OF CENTER OF UTILITIES- DETERMINED BY CLEARING LIMITS -EX. SANITARYFORCE MAINSSMHRIM = 168.08INV = 148.982+502+003+003+500+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00PC =4+04.71Rad =2217.39'4+50 5+00 PT =5+09.601+001+50LP =2+52.79EL = 169.85'HP =3+23.48EL = 170.11'HP =3+25.96EL = 169.22'EL = 168.79'LP =2+25.00 EL = 169.50'HP =1+01.00 EL = 169.33'LP =0+51.58 LP =4+15.68EL = 168.15' 5.0' CONCSIDEWALK 50.0'ROW 24.0'EOP-EOP WATER SERVICE(TYP) SEWER SERVICE(TYP.) 8" PVC SANITARYSEWER MAIN CL INTERSECTIONSTUB RD STA = 0+00MAIN RD STA = 2+03.64 6" C-900 PVCWATER LINECI-28CI-12CI-13CI-18CI-15 CI-16 CI-14 CI-17SMH-1SMH-7 SMH-8 50' RAD. GRAVEL TEMP.TURN-AROUND -SEE DETAIL C-7.1 TEMPORARYACCESS ESMT CL STA 4+09,17.34' RTFIRE HYDRANTASSEMBLY 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 STA =0+00Main RdEL = 170.03PVI STA. 0+38.00PVI ELEV. 169.23'PVC STA. 0+13.00PVC ELEV. 169.65'SAG STA. 0+51.58SAG ELEV. 169.33'PVT STA. 0+63.00PVT ELEV. 169.36'50.00' VCAD2.1922.83' K-Val PVI STA. 1+06.00PVI ELEV. 169.57'PVC STA. 0+81.00PVC ELEV. 169.45'CREST STA. 1+01.00CREST ELEV. 169.50'PVT STA. 1+31.00PVT ELEV. 169.38'50.00' VCAD-1.2540.00' K-Val PVI STA. 2+20.00PVI ELEV. 168.72'PVC STA. 1+95.00PVC ELEV. 168.90'SAG STA. 2+25.00SAG ELEV. 168.79'PVT STA. 2+45.00PVT ELEV. 168.84'50.00' VCAD1.2540.00' K-Val PVI STA. 3+41.64PVI ELEV. 169.32'PVC STA. 3+16.64PVC ELEV. 169.20'CREST STA. 3+25.96CREST ELEV. 169.22'PVT STA. 3+66.64PVT ELEV. 168.78'50.00' VCAD-2.6818.64' K-Val PVI STA. 4+00.00PVI ELEV. 168.05'PVC STA. 3+75.00PVC ELEV. 168.60'SAG STA. 4+15.68SAG ELEV. 168.15'PVT STA. 4+25.00PVT ELEV. 168.17'50.00' VCAD2.6818.64' K-Val CL STA =0+18.586" WL WLINV = ±165.8'CL STA =0+51.5815" RCPINV = ±166.1'CL STA =2+25.0015" RCPINV = ±165.5'CL STA =4+15.6915" RCPINV = ±165.0'CI-16SMH-8CI-17SMH-7CI-18CI-12PROPOSED GRADE EXISTING GRADE 6" WL PVC WATER LINE 8" SDR-26 PVC SANITARY SEWER MAIN 8" GABC GRAVELTURN-AROUND Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSCALE IN FEET 0'15 30 60NORTH STEPPING STONE LANE SCALE: HORIZ. 1"=30' VERT. 1"=5' (PUBLIC & UTILITY R/W) SCALE: 1"=30'ROADWAY PLAN AND PROFILEC5.2 NOTE: STORM DRAINAGE RIM ELEVATION ISREFERENCED FROM EDGE OF PAVEMENT FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT. NCDOT STANDARD NOTES: 1. ALL UTILITY STRUCTURES SHALL BE LOAD RATED FOR THE APPROPRIATE DEADLOAD PLUS HL-93 LIVE LOAD. SUCH STRUCTURES SHALL BE DESIGNATED ANDCERTIFIED BY A LICENSED PE OR DESIGNATED AS MEETING NCDOT STANDARDSPECIFICATIONS AND DRAWINGS. 2. ELECTRICAL POWER AND COMMUNICATIONS FACILITIES SHOULD CONFORM TOTHE CURRENTLY APPLICABLE NATIONAL ELECTRICAL SAFETY CODE EXCEPT VERTICALCLEARANCES SHALL BE NO LESS THAN 18 FEET IN ANY CASE. 3. ALL NON-FERROUS PIPELINES SHALL BE INSTALLED WITH A LOCATING TAPE. 4. ANY SUBDIVISION MARKER WILL NEED TO BE LOCATED OUTSIDE OF RIGHT OFWAY. STEPPING STONE LANE DRAINAGE STRUCTURESNAME RIM / EOP INV. IN (1) INV. IN (2) INV. OUTCI-14 168.43 165.40 164.51 164.26CI-17 168.43 N/A N/A 165.68CI-15 167.79 164.99 N/A 164.89CI-16 167.79 N/A N/A 165.04 STORM DRAINAGE PROFILE AND PIPE DATASEE OVERALL STORM DRAINAGE PLAN ANDSTORM DRAINAGE PROFILE SHEETS SANITARY SEWER AND WATER MAIN DATA -SEE SANITARY SEWER AND WATER MAINPLAN AND PROFILE SHEETS WWSS SS SS SS SS SS SS 1011121314151617181930SSSSSSSS2120WWWWWWWWWWW1,045.52'S 02°48'51" W 1.075.54' TOTALTWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03SSMHRIM = 168.85INV = 148.456+005+005+50CURVE 1A= 39.16'R= 230.00'ΔD= 9°45'23"C= 39.12'DOC= 24°54'40"0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+13.05 PC =6+17.30Rad =230.00'6+50PT =6+56.46PC =6+56.46Rad =230.00'7+00HP =5+95.81EL = 169.25'LP =7+15.80EL = 168.74'HP =1+04.92EL = 169.08' LP =4+38.73EL = 167.83' EL = 168.80'LP =0+41.00 EL = 168.21'LP =2+20.16 HP =3+04.77EL = 168.73' 5.0' CONCSIDEWALK 50.0'ROW 24.0'EOP-EOP WATER SERVICE(TYP)6" C-900 PVCWATER LINE CL INTERSECTIONSTUB RD NORTH STA = 0+00MAIN RD STA = 5+96.42 CI-10CI-9CI-8CI-7 CI-6CI-24 SMH-3SMH-4CI-23 CI-22 CI-21: DBL GRATEINLET CI-20CI-19: DBL GRATE INLET 50' RAD. GRAVEL TEMP.TURN-AROUND-SEE DETAIL C-7.1 TEMPORARYACCESS ESMT SMH-10SMH-9 8" PVC SANITARYSEWER MAIN CL STA 4+12,19.57' RTFIRE HYDRANTASSEMBLY 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 STA =0+00Main RdEL = 169.25PVI STA. 0+12.00PVI ELEV. 168.89'PVI STA. 0+46.00PVI ELEV. 168.72'PVC STA. 0+21.00PVC ELEV. 168.85'SAG STA. 0+41.00SAG ELEV. 168.80'PVT STA. 0+71.00PVT ELEV. 168.91'50.00' VCAD1.2540.00' K-Val PVI STA. 1+08.49PVI ELEV. 169.19'PVC STA. 0+83.49PVC ELEV. 169.00'CREST STA. 1+04.92CREST ELEV. 169.08'PVT STA. 1+33.49PVT ELEV. 168.94'50.00' VCAD-1.7528.57' K-Val PVI STA. 2+18.25PVI ELEV. 168.09'PVC STA. 1+93.25PVC ELEV. 168.34'SAG STA. 2+20.16SAG ELEV. 168.21'PVT STA. 2+43.25PVT ELEV. 168.31'50.00' VCAD1.8626.91' K-Val PVI STA. 3+04.65PVI ELEV. 168.83'PVC STA. 2+79.65PVC ELEV. 168.62'CREST STA. 3+04.77CREST ELEV. 168.73'PVT STA. 3+29.65PVT ELEV. 168.62'50.00' VCAD-1.7129.27' K-Val PVI STA. 4+32.40PVI ELEV. 167.75'PVC STA. 4+07.40PVC ELEV. 167.96'SAG STA. 4+38.73SAG ELEV. 167.83'PVT STA. 4+57.40PVT ELEV. 167.88'50.00' VCAD1.3636.86' K-Val CL STA =0+17.616" WL WLINV = ±165.3'PVT STA. 4+57.40PVT ELEV. 167.88'CL STA =0+44.0030" RCPINV = ±161.8'CL STA =2+20.1615" RCPINV = ±165.0'CL STA =3+50.0015" RCPINV = ±165.2'CL STA =4+38.7315" RCPINV = ±164.7'CI-21SMH-10CI-20CI-19CI-9SMH-9PROPOSED GRADE EXISTING GRADE 6" WL PVC WATER LINE 8" GABC GRAVELTURN-AROUND 8" SDR-26 SANITARYSEWER MAIN Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSCALE IN FEET 0'15 30 60 BOOKRAND LANE SCALE: HORIZ. 1"=30' VERT. 1"=5' SCALE: 1"=30'ROADWAY PLAN AND PROFILEC5.3NORTHNOTE: STORM DRAINAGE RIM ELEVATION ISREFERENCED FROM EDGE OF PAVEMENT FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT. NCDOT STANDARD NOTES: 1. ALL UTILITY STRUCTURES SHALL BE LOAD RATED FOR THE APPROPRIATE DEADLOAD PLUS HL-93 LIVE LOAD. SUCH STRUCTURES SHALL BE DESIGNATED ANDCERTIFIED BY A LICENSED PE OR DESIGNATED AS MEETING NCDOT STANDARDSPECIFICATIONS AND DRAWINGS. 2. ELECTRICAL POWER AND COMMUNICATIONS FACILITIES SHOULD CONFORM TOTHE CURRENTLY APPLICABLE NATIONAL ELECTRICAL SAFETY CODE EXCEPT VERTICALCLEARANCES SHALL BE NO LESS THAN 18 FEET IN ANY CASE. 3. ALL NON-FERROUS PIPELINES SHALL BE INSTALLED WITH A LOCATING TAPE. 4. ANY SUBDIVISION MARKER WILL NEED TO BE LOCATED OUTSIDE OF RIGHT OFWAY. STORM DRAINAGE PROFILE AND PIPE DATASEE STORM DRAINAGE PROFILE SHEETS SANITARY SEWER AND WATER MAIN DATA -SEE SANITARY SEWER AND WATER MAINPLAN AND PROFILE SHEETS (PUBLIC & UTILITY R/W)BOOKRANE LANE CI-19 167.85 163.87 164.82 163.37 CI-20 168.09 164.39 165.07 164.14 CI-21 167.47 164.67 N/A 164.57 CI-22 167.47 N/A N/A 164.72 CI-23 168.09 N/A N/A 165.34CI-24 167.85 N/A N/A 165.10 DRAINAGE STRUCTURES NAME RIM / EOP INV. IN (1) INV. IN (2) INV. OUT WWWWWWW W W W W W W W WWWSS SS SS SS SS SS SS SS SS SS SS SS SS SS 12345678910111213141516171819313029282726252423SSSSSSSSSSSSSSSSSSSSSSSSSSSS SS 2133322022343536WWWWWWWWWWWW W W W WW156160158168167166165164163162156157161160159158161RCP OHUOHU RUSSELL LYNN HAYESNO DEED FOUNDPIN: 0524-67-1662.000PID: 010524 0063OHU HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED) OHU RCPPHONEPEDESTAL OHUTOMMY LYNN MCPHAIL AND WIFE,BONNIE H. MCPHAILDEED BOOK 684, PAGE 606PIN: 0524-58-4260.000PID: 010534 0079 01WATERVALVEOHU SS KRISTA HERNANDEZDEED BOOK 3971, PAGE 938PLAT BOOK 2001, PAGE 833PIN: 0524-57-0707.000PID: 010524 0069 08FEDERAL NATIONAL MORGAGEDEED BOOK 3882, PAGE 330PLAT BOOK 2002, PAGE 1445PIN: 0524-47-8778.000PID: 010524 0069 07RUSSELL L. HAYES AND WIFE,KIMBERLY S. HAYESDEED BOOK 1045, PAGE 496PLAT CABINET F, SLIDE 269-BPIN: 0524-68-1621.000PID: 010524 0063 02TWO ADAMS, INCDEED BOOK 3067, PAGE 902PLAT CABINET F, SLIDE 269-BPIN: 0524-58-9529.000PID: 010524 0063 03TOM HUGH JOHNSONDEED BOOK 3945, PAGE 126PLAT CABINET F, SLIDE 305-DPLAT CABINET 2, SLIDE 247PLAT BOOK 98, PAGE 271PIN: 0524-57-0707.000PID: 010524 0069 08RCP RCPRCPRCP RCP RCP 16" GRAVITY FEEDSANITARY SEWEREXISTING SOIL DRIVEEXISTING 40' UTILITY EASEMENT20' EITHER SIDE OF CENTER OF UTILITIES- DETERMINED BY CLEARING LIMITS -IRON 3/4EX. DRAINAGE CHANNEL >>EXISTING GRAVEL DRIVEEX 30' ACCESSEASEMENTPLAT BOOK 98, PG 271CONC.MONUMENTEXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF 16" GRAVITYFEED SANITARY SEWER16" GRAVITY FEED SANITARY SEWEREXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF UTILITY- DETERMINED BY CLEARING LIMITS -IRON 3/4EX. SANITARYFORCE MAIN6" WATER LINE PER GISIRON 5/8"N:548092.95E:2025804.67N:548128.77E:2025101.13EX. OVERHEADPOWER LINESSMHRIM = 168.60INV = 147.66SSMHRIM = 168.50INV = 148.06SSMHRIM = 168.85INV = 148.45SSMHRIM = 168.08INV = 148.98SSMHRIM = 127.27INV = 149.22SSMHRIM = 173.39INV = 149.290+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00PC =4+04.71Rad =2217.39'4+50 5+00 PT =5+09.60HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED) <<176LF - 24" RCP @ 0.60% <<130LF - 18" RCP @ 0.21%<<89LF - 15" RCP @ 0.20% <<173LF - 18" RCP @ 0.20% << 191LF - 15" RCP @ 0.20% 169LF - 36" RCP @ 0.20% >> 77LF - 30" RCP @ 0.20% >>88LF - 30" RCP@ 0.20 % >>64LF - 30" RCP@ 0.20% >>68LF - 30" RCP@ 0.20% >>98LF - 24" RCP@ 0.20% >>199LF - 24" RCP @ 0.20% >>CI-21 - DBL GRATERIM = 167.47'INV. IN = 164.67'INV. OUT = 164.57 CI-22RIM = 167.47'INV. OUT = 164.72 CI-23RIM = 168.09'INV. OUT = 165.34 CI-20RIM = 168.09'INV. IN = 165.07'(CI-23)INV. IN = 164.39'(CI-21)INV. OUT = 164.14 CI-24RIM = 167.85'INV. OUT = 165.10 CI-19 - DBL GRATERIM = 167.85'INV. IN = 164.82'(CI-24)INV. IN = 163.87'(CI-20)INV. OUT = 163.37 CI-8RIM = 168.44'INV. IN = 161.77'INV. OUT = 161.67 CI-27RIM = 167.97'INV. OUT = 165.22 CI-11RIM = 167.97'INV. IN = 162.81'(CI-12)INV. IN = 164.95'(CI-27)INV. OUT = 162.71 CI-10RIM = 168.66'INV. IN = 162.51'INV. OUT = 162.41 CI-9RIM = 168.44'INV. IN = 162.32'(CI-19)INV. IN = 162.32'(CI-10)INV. OUT = 161.82 CI-7RIM = 168.70'INV. IN = 161.58'INV. OUT = 161.48 CI-26RIM = 168.38'INV. OUT = 165.63 CI-6RIM = 168.38'INV. IN = 161.34'(CI-7)INV. IN = 165.35'(CI-26)INV. OUT = 161.24 CI-5RIM = 168.79'INV. IN = 161.11'INV. OUT = 161.01 CI-25RIM = 168.51'INV. OUT = 165.86 CI-4RIM = 168.51'INV. IN = 160.84'(CI-5)INV. IN = 165.24'(CI-25)INV. OUT = 160.74 CI-3RIM = 168.13'INV. IN = 160.59'(CI-4)INV. IN = 163.14'(CI-29)INV. OUT = 160.09 CI-29RIM = 168.11'INV. OUT = 165.36 CB-2RIM = 168.00'INV. IN = 159.75'INV. OUT = 159.65 OUTFALLINV. OUT = 159.56 40LF - 36"RCP @ 0.20% 72LF - 15" RCP@ 3.07% 27LF - 15" RCP@ 2.33% 27LF - 15" RCP@ 1.05% 44LF - 30" RCP@ 0.20% 27LF - 30" RCP@ 0.20% 45LF - 24" RCP@ 0.20% 27LF - 15" RCP@ 1.02% CI-12RIM = 169.48'INV. IN = 163.30'(CI-13)INV. IN = 166.45'(CI-28)INV. OUT = 163.20CI-28RIM = 169.48'INV. OUT = 166.73 27LF - 15" RCP@ 1.05% CI-13RIM = 168.97'INV. IN = 163.91'(CI-14)INV. IN = 166.00'(CI-18)INV. OUT = 163.41 53LF - 24" RCP @ 0.20%CI-14RIM = 168.43'INV. IN = 164.51'(CI-15)INV. IN = 165.40'(CI-17)INV. OUT = 164.26 CI-17RIM = 168.43'INV. OUT = 165.68 27LF - 15" RCP@ 1.05% CI-15RIM = 167.79'INV. IN = 164.99'INV. OUT = 164.89 CI-16RIM = 167.79'INV. OUT = 165.04 27LF - 15" RCP@ 0.20% CI-18RIM = 168.97'INV. OUT = 166.22 27LF - 15" RCP@ 1.05%27LF - 15" RCP@ 1.02% 27LF - 15" RCP@ 0.20% FEETSCALE 0 50 100 HORZ. Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONOVERALL STORM DRAINAGE PLANC6.0NORTH NOTE:CURB INLET (CI) "EOP" ELEVATION IS REFERENCED ATEDGE OF PAVEMENT. CATCH BASIN (CB) "RIM" ELEVATION REFERENCE ATCENTER OF GRATE. ALL STORM DRAINAGE PIPES ARE RCP CLASS III, UNLESSOTHERWISE NOTED. HOR: 1" = 30 VERT: 1" = 5 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 << 176-LF 24" RCP @ 0.60% << 130-LF 18" RCP @ 0.21%<< 89-LF 15" RCP @ 0.20%<<CI-9EOP = 168.44INV IN = 162.32 (CI-19)INV IN = 162.32 (CI-10)INV OUT = 161.82CI-19EOP = 167.85INV IN = 163.87 (CI-20)INV IN = 164.82 (CI-24)INV OUT = 163.37CI-20EOP = 168.09INV IN = 164.39 (CI-21)INV IN = 165.07 (CI-23)INV OUT = 164.14CI-21EOP = 167.47INV IN = 164.67 (CI-22)INV OUT = 164.57CI-22EOP = 167.47INV OUT = 164.7227-LF 15" RCP@ 0.20% PROPOSED GRADE EXISTING GRADE 0+00 0+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 0+00 0+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 0+00 0+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 0+00 0+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 0+00 0+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 0+00 0+50 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 8" SDR-26 PVCINV = ±161.8'8" SDR-26 PVCINV = ±160.4'8" SDR-26 PVCINV = ±161.8'8" SDR-26 PVCINV = ±157.0'8" SDR-26 PVCINV = ±159.2'8" SDR-26 PVCINV = ±157.9'<<CI-20STA=0+00EOP = 168.09INV IN = 165.07 (CI-23)INV IN = 164.39 (CI-21)INV OUT = 164.14CI-23STA=0+27EOP = 168.09INV OUT = 165.348" SDR-26 PVCINV = ±161.8'<<CI-19EOP = 167.85INV IN = 164.82 (CI-24)INV IN = 163.87 (CI-20)INV OUT = 163.37CI-24EOP = 167.85INV OUT = 165.10<<CI-6EOP = 168.38INV IN = 165.35 (CI-26)INV IN = 161.34 (CI-7)INV OUT = 161.24CI-26EOP = 168.38INV OUT = 165.638" SAN SEWERINV = ±159.2' <<CI-4EOP = 168.51INV IN = 165.24 (CI-25)INV IN = 160.84 (CI-5)INV OUT = 160.74CI-25EOP = 168.51INV OUT = 165.86<<CI-12EOP = 169.48INV IN = 166.45 (CI-28)INV IN = 163.30 (CI-13)INV OUT = 163.20CI-28EOP = 169.48INV OUT = 166.738" SAN SEWERINV = ±157.0' <<CI-11EOP = 167.97INV IN = 164.95 (CI-27)INV IN = 162.81 (CI-12)INV OUT = 162.71CI-27EOP = 167.97INV OUT = 165.228" SAN SEWERINV = ±157.9' 27-LF 15" RCP@ 1.02% 27-LF 15" RCP@ 1.05% 27-LF 15" RCP@ 2.33% 27-LF 15" RCP@ 1.05%27-LF 15" RCP@ 1.05%27-LF 15" CL. V RCP@ 1.02% Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSTORM DRAINAGE PROFILESC6.2 FEETSCALE 0 30 60 HORZ. FEETSCALE 0 5 10 VERT. CONCRETE PIPE CONCRETE PIPE "A" "A" SECTION "A"-"A" 2.00'2.00'DIA. VARIESGEOTEXTILENON-WOVEN FABRIC W/ 1' MIN. OVERLAP PIPE JOINT TOUNGE &GROOVEJOINTS MASTIC SEAL SCALE: N.T.S. PIPE JOINT 4" 12"12" NOTES: 1. MIN. 6" #57 STONE BEDDING SHALL BE REQUIRED IF TRENCHBOTTOM IS BELOW THE GROUND WATER TABLE. 2. FILL SHALL BE NATIVE MATERIAL FREE OF LARGE ROCKS,DEBRIS OR ORGANICS PLACED IN 6" LIFTS AND COMPACTEDTO 95% OF THE SOIL'S MODIFIED PROCTOR. FINISHED GRADE NATIVE BEDDINGMATERIAL. SEENOTES BELOW. FILL MATERIAL SLOPE TRENCH PEROSHA REQUIREMENTS SCALE: N.T.S. REINFORCED CONCRETE PIPE BEDDING TOP VIEW SECTION A-A A A 6'-1 3/4" 24" 30" 36" 6'-1" 8'-2" DIMENSIONS DIA. 15" 18" L 6'-1" 6'-1" L PIPEDIA.DIA.SCALE: N.T.S. FLARED END SECTION GENERAL NOTES: 1. INSTALLATION REQUIRES A MINIMUM OF ONE 4'-0" LONG SECTION OFREINFORCED CONCRETE PIPE BETWEEEN CATCH BASINS. 2. CONSTRUCT TWO SINGLE BASINS PER NCDOT STANDARD WITHDOUBLE INTERIOR WALL. 3. ALL CONCRETE TO BE 3000 P.S.I COMPRESSIVE STRENGTH. 4. BASE SLAB SHALL BE MONOLITHIC. 5. PIPE SECTION D2 CONNECTING CATCH BASINS SHALL HAVE AMINIMUM DIAMETER SAME AS OF OUTLET PIPE D3. 6. ALL REINFORCING STEEL SHOWN ON NCDOT STANDARDS IS TO BEPROVIDED AS CONTINUOUS MEMBERS. (NO LAPS, USED AS A SINGLECONTINUOUS BAR IN THE SLAB) 7. STEP SHALL BE INSTALL IN ALL CATCH BASINS OVER 3' IN DEPTH.DEPTH SHALL BE MEASURED FROM TOP OF CURB TO THE INVERT OFTHE CATCH BASIN. 8. SOLID CONCRETE BRICKS MAY BE USED IN 4" X 4" X 16" OR4" X 8" X 16" SIZES. PLAN VIEW DOUBLE FRAME AND GRATE(STD 840.03) BRICK DROP INLETSTD. 840.27 -NCDOT APPROVED PRECASTCONCRETE BOXES ACCEPTABLE,USING STANDARD 5' CASTINGS SECTION A-A VIEW 4"16" 4" 3 - #4 REBARS RCP SLOPERCP 6" MINIMUM OF ONE 4'-0" LONGSECTION OF REINFORCED CONCRETEPIPE BETWEEN BASINS. SEE NOTE 5THIS SHEET FOR PIPE SIZE. OUTLETPIPE INLETPIPE RCPPIPE SLAB TO BE MONOLITHICAND REINFORCING TO BECONTINUOUS A A SITE DETAILC7.0 NOT TO SCALE NCDOT CONCRETE CATCH BASIN NOT TO SCALE NCDOT FRAME AND GRATE DETAIL NOT TO SCALE CURB INLET DETAIL 12" O.C.E.W.#4 REBAR @ DRAIN LINESTORM STORM DRAIN LINE TOP OF CURB VARIES(SEE PLANS)OR PRECAST CONCRETE BOX8" SOLID CONCRETE BRICK DEPTH IS MORE THAN 3'-0"MANHOLE STEPS @ 16" O.C. IFGRADE 60 REINFORCEMENTPLASTIC, REINFORCED WITH 1/2"COPOLYMER POLYPROPYLENEALL STEPS IN MANHOLES ARE SUBGRADECOMPACTED 2'-2" FRAME ANDGRATE WITH HOODCURB, GRADE SMOOTH,BACKFILL TO TOP OF SEED AND MULCH RIM = EOP OR CONCRETE INLET BOXES.NOTE: NCDOT STD. #840.01 #840.02 MASONRY FOUNDATION3000PSI CONCRETE ELEVATION (TYP.) SEE NCDOT FRAME AND GRATE DETAIL NOT TO SCALE DOUBLE WIDTH CATCH BASIN DETAIL 6'-4"6'-4" Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION SITE DETAILC7.1 DESCRIPTIONSYMBOL PAVEMENT SCHEDULE C1 E1 TYPICAL LOCAL RESIDENTIAL ROAD CROSS SECTION T PROPOSED 8" ABC COMPACTED TO 100 PERCENT. PREPARED SUBGRADE: COMPACTED TO A MINIMUM OF 98% OF THE SOIL'SMODIFIED PROCTOR DENSITY ( ASTM 698) PLACE IN 6: LIFTS. PROVIDE TESTRESULTS FOR SUBGRADE COMPACTION. PROPOSED 2" ASPHALT SURFACE COURSE TYPE S9.5B TYPICAL CUL-DE-SAC DETAIL NOT TO SCALE SECTION A-AC/L35' SLOPE AS REQUIRED NOTES: 1. ALL ROADWAY FOLLOWS NCDOT SUBDIVISION ROADSTANDARDS UNLESS OTHERWISE NOTED. 2. DEVELOPMENT SHALL COMPLY WITH THE HARNETT COUNTY UDO LATEST EDITIONS. 3. THE PROPOSED PROJECT IS IN HARNETT COUNTYJURISDICTION. 3.0% CL 3.0% 50' R.O.W. 30" & GUTTER RW RW EDGE OF PAVEMENT ANDABC DETAIL ABC STONE: (TYP.)12" 30" VALLEY CURB 2:1 2:15.0' SIDEWALK 2:12:1T E1 C1 R/W2.5' VALLEY CURB 2.0' R45'ROW R25' R17' 24'EOP 50'ROW R35' 30" & GUTTERVALLEY CURB 24' PAVEMENT WIDTH 12.0'12.0' 10.5' 2.0%2.0% 3.5' 5' SIDEWALK 2.0% NOT TO SCALE 30" VALLEY TYPE CURB & GUTTER NOT TO SCALE 18"12" 4" 7" 11" 4.5" 6.5" 4:1 SLOPE = 1/2" / FT.1:1NOTES: 2. 1/2" EXPANSION JOINT EVERY 50'. 15' MAXIMUM BETWEEN DUMMY JOINTS ONMACHINE POURS. 3. 3000 PSI CONCRETE MINIMUM, 4" SLUMP MAXIMUM. 4. LIQUID MEMBRANE CURING COMPOUND SHALL MEET THE REQUIREMENTS OF SECTION 1026-2 OF NCDOTSTANDARDS & SPECIFICATIONS FOR ROADS AND STRUCTURES. 5. ALL CONSTRUCTION JOINTS SHALL BE FILLEDWITH JOINT FILLER AND SEALER IN ACCORDANCEWITH NCDOT ROADWAY STANDARD DETAIL 846.01THE JOINT MATERIAL SHALL CONFORM TO SECTION ROADS AND STRUCTURES. 1. 10' MAXIMUM BETWEEN DUMMY JOINTS. 1028-2 OF NCDOT STANDARD & SPECIFICATIONS FOR 2'-6"2'-6" 2'-6" 2'-6"FACE OF CURB 10'-0" AA 30" BB 7" CC A B C LIP OF GUTTER C PLAN VEIW A B SECTION C-C SECTION B-BSECTION A-A BACK OF CURB 2'-6" JOINT 7" FACE OF CURB JOINT 10'-0" 5'-0" 1/2 " EXPANSION 1/2 " EXPANSION 7" 2'-6"2'-6"2'-6"2'-0"6"1"7 1/2"8 3/4" 7"7"12"12" REQUIRED TRANSITION LENGTH 10" 11" TRANSITION NOT TO BE LOCATED WITHIN THE CURB RADIUS. NOTES: CURB TRANSITION TO 30" VALLEY GUTTER NOT TO SCALE PARALLEL CURB RAMP WITH DETECTABLE DOME NOT TO SCALE SECTION "A-A" 6" CONC.SIDEWA L K ACCESS RAMP 24.28121.70913-EQUAL SPACESPART O.A.1.2711.286R.1254-PL. 49.060 0.443PART O.A.0.135.20018-PL..5004-SIDES 30.1975.0625.7500 30 .900 .0625.480 79 18-PL DIA. 18-PL..500 DIA. 260 PL. .090 DEG POINT.045 HIGH 0.13501/4'' DIA. CTSK HOLES(TYP. 15 LOCATIONS) 1/4'' X 1 1/2'' LG.EXPANSION ANCHOR TILE INSTALLATIONVIEW B 4X SCALE WITH DETECTABLE WARNING PAVERS SLOPE 12:1 MAX (5'-4" MIN.) 2' DETECTABLE WARNING DOMESSEE NOTE #1 CURB & GUTTER DEPRESSED CURB 4" CONCRETEFOUNDATION 2" STANDARD 2'- 6".200DOME 406 PL.''B''''B'' HALF SCALE SURFACE APPLIED/RETROFITDETECTABLE WARNING SURFACE SYSTEM EXISTING CONCRETE (4' MIN LANDING) 1. DETECTABLE WARNING DOMES SHALL COVER 2'-0" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL. 2. THE COLOR FOR THE DETECTABLE WARNING AREA SHALL BE YELLOW FOR CONTRAST. NOTES: SECTION "B" TYPICAL SECTION NOTE: THIS APPLICATION ONLY TO BE USEDWHEN RETRO FITTING EXISTINGBARRIER FREE RAMPS WALLTHICKNESSDETECTABLE WARNING SURFACE, SURFACE APPLIED (RETROFIT ONLY) NOT TO SCALE 6'CONCRETESIDEWALK DUMMY JOINT EXPANSION JOINT EXPANSION JOINT 6"CONC 8" CONC.WITHIN WING AREAE.J. EXPANSIONJOINT DUMMY JOINT 3.5'E.J. 3.5' 6' GRASSEDSTRIP 12' STD. 30" VALLEY CURB & GUTTER 3. ALL CONCRETE SHALL BE 3000 PSI (MIN.). 1. SEE 30" VALLEY CURB AND GUTTER DETAILS. 2. EXPANSION MATERIAL SHALL EXTEND THE FULL DEPTH OF THE CONCRETE. NOTES: DRIVEWAY FOR VALLEY TYPE CURB & GUTTER NOT TO SCALE TRANSVERSE EXPANSION JOINT TYPICAL SECTION PLAN VIEW COMPACTED TO A DENSITY OF NO LESS THAN 95% 1/4"/FT SIDEWALK SURFACEJOINT FILLERPROPOSED SIDEWALKRIGHT OF WAY LINE4" 1/2"GRASS STRIPUTILITY EASEMENT2'5'5' 2'30" VALLEY CURBSAW CUTJOINTS @ 6'MAXIMUM30" VALLEY CURB GRASSED UTILITY STRIP 1/4"/FT 1/4"/FT PROPOSED SIDEWALK(3000 P.S.I.) R/W 1. TRANSVERSE EXPANSION JOINTS TO BE A MAXIMUM OF 50 FEET. 2. ALL CONCRETE TO BE 3000 PSI AND FINISHED WITH CURING COMPOUND. 3. A 6 INCH DEPTH IS REQUIRED AT LOCATIONS OF DRIVEWAY CROSSINGS, AT STREET INJTERSECTIONS (ALONG THE LENGTH OF RADIUS CURB RETURNS),AND IN THE HANDICAP RAMPS. NOTES: CONCRETE SIDEWALK NOT TO SCALE SCALE: N.T.S. TEMPORARY GRAVEL TURN-AROUND 24' WIDE SLOPE TO MATCH TYPICALROAD SECTION(TYP) TEMPORARYACCESS EASEMENT 1/4" PERFT. SLOPE GABC TO MATCH TOTALTHICKNESS OF TYPICALROAD SECTION SELECT FILL TO MATCHTYPICAL ROAD SECTIONSPECIFICATIONS R 50' CENTER LINETEMPORARYALL WEATHERACCESS ROAD GRADE TO EXISTING SEEDED AREA SEEDED AREA +0.50' +0.50' +0.00' 6' RA M P(12:1 M A X . ) EDGE O F P A V E M E N T 2.0% SLO P E M A X. SCORED CONCRETE +0.00'3/8" TROWELCONTROL JOINT(SCORING) 5' x 5'LAND I N G REJECTCURB H A N D I C A P L A N D I N G 1 2 : 1 S L O P E (M A X . ) 5' SIDEWALK 5' SIDEWALK 2.00% SLOPE MAX. E D G E O F A S P H A L T TACTILE WARNINGSURFACE TREATMENT -SEE DETAIL CONCRETE CURBAND GUTTER SCOREDCONCRETE 6" CONCRETE CURB +0.50' +0.50' +0.00' +0.00' +0.60' +0.60' +0.60' +0.10' +0.10' TACTILE WARNINGSURFACE TREATMENT -SEE DETAIL Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTION 31SSSS SS333234 3536W W W W WW156160158168167166165164163162156157161160159158167166165164163162 156158 168 1610255075100125150175200225250263.5316816816716616416516916816716616416316216116516016916916916816716 8 169169RCP 289 LF 15" RCP OUTLETBARREL @ 0.35% SLOPE INV OUT = 159.00' STORMWATERMANAGEMENTEASEMENT 20' DRAINAGE &ACCESSEASEMENT INV OUT = 160.00' DOUBLE GABIONBASKET WEIR 2'-2" X 3' PRECAST CONCRETERISER WITH TRASH RACK -SEE DETAIL STORMWATERMANAGEMENTEASEMENT N:548926.87E:2025229.17 N:548980.78E:2025158.62 N:549105.14E:2025251.94 N:549118.67E:2025320.61 N:549137.21E:2025856.01 N:548882.77E:2025542.72 N 5 2 ° 3 6 ' 5 9 " W 88. 7 9 'N 36°53'11" E155.48'N 78°51'07" E 69.98' N 88°01'02" E 535.72'S 02°48'51" W270.67'N 86°57'55" W 283.31' S 86°54'21" E 126.20'N 11°45 '53" W133.10 ' A= 96.65'R= 383.16'ΔD= 14°27'10"C= 96.40'DOC= 14°57'12" A= 96.65'R= 383.16'ΔD= 14°27'10"C= 96.40'DOC= 14°57'12" A= 36.71'R= 45.00'ΔD= 46°44'46"C= 35.70'DOC= 127°19'26"N:548901.38E:2025573.19 N:549024.87E:2025672.07 ANTI-SEEPAGECOLLAR - SEE DETAIL VEGETATIVE LITTORALSHELF ANTI-SEEPAGECOLLAR - SEE DETAIL STORMWATER MANAGEMENT DESIGN WET DETENTION POND DESIGN STORM POST-RUNOFF STORM STAGE PRE-RUNOFF POND OUTFLOW1-YEAR (24 HR) 0.74 CFS 161.54 FT-MSL 0.30 CFS 0.07 CFS10-YEAR 30.10 CFS 162.86 FT-MSL 12.04 CFS 11.63 CFS25-YEAR 33.49 CFS 163.06 FT-MSL 13.39 CFS 12.42 CFS50-YEAR 35.82 CFS 163.25 FT-MSL 14.33 CFS 13.15 CFS100-YEAR 38.04 CFS 163.45 FT-MSL 15.22 CFS 13.86 CFS DRAINAGE AREA TO POND: 14.61 AC. SITE IMPERVIOUS AREA TO POND: 3.71 AC. 0+00 0+50 1+00 1+50 2+00 2+50 3+00 150 152 154 156 158 160 162 164 166 168 170 150 152 154 156 158 160 162 164 166 168 170 168.5168.51168.3168.28168.3168.33168.2168.23168.0167.96167.6167.583 1 3 1 BOTTOM OF PONDEL: 156.00' TEMPORARY POOL EL: 162.00 NORMAL POOL EL: 161.00' 10 YR EL: 162.86' 25 YR EL: 163.06'50 YR EL: 163.25'100 YR EL: 163.45' NOTE:ALL SEDIMENT DEPOSITED IN THE POND DURINGCONSTRUCTION MUST BE REMOVED, EROSION FEATURESMUST BE REPAIRED, AND THE VEGETATED SHELF MUST BERESTORED, BEFORE OPERATION AS A STORMWATER BMPBEGINS. NOTE:THE CONTRACTOR SHALL ENSURE THAT THE POND HAS AMAXIMUM INFILTRATION OF 0.01 IN/HR. THIS MAY BEACCOMPLISHED BY RE-DISTRIBUTING EXISTING CLAYS ORUSING BORROW CLAY AS NECESSARY AS DIRECTED BY THEGEOTECHNICAL ENGINEER. THE CONTRACTOR SHALL HAVE A NC LICENSEDGEOTECHNICAL ENGINEER VERIFY A MAXIMUM OF 0.01IN/HR INFILTRATION PRIOR TO CONVERTING THEEXCAVATED AREA FROM A SEDIMENT BASIN TO APERMANENT WET DETENTION BASIN. IF 0.01 IN/HRMAXIMUM INFILTRATION CANNOT BE MAINTAINED , APERMANENT LINER WILL NEED TO BE INSTALLED . IF ALINER IS USE, THE SOIL MUST BE TESTED FOR INFILTRATIONRATE PRIOR TO INSTALLATION BY A NC LICENSEDGEOTECHNICAL ENGINEER. 6: 1 BOTTOM OF SHELF: 161.00' BOTTOM OF SHELF: 162.00' TOP OF BASIN: 167.50 EXISTING GROUND DOUBLE GABIONBASKET WEIR FOR THEFIRST 3 FEET.TOP OF GABION EL = 162.00' SEDIMENT CLEANOUT: 157.00' 6" CLAY SOIL LINERMAIN POOL 6" TOP SOIL ABOVE6" CLAY LINER ONLITTORAL SHELF THE ENTIRE TOP OF DAM ACT ASEMERGENCY SPILLWAY. THE ENTIRE100-YR STORM EVENT AND LARGERSTAYS WITHIN THE POND Know what's belowCall before you dig.Dial 811 Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONSTORMWATERMANAGEMENT DETAILSC8.0 DRAW DOWN ORIFICE DETAIL RISER PERMANENTPOOL OUTLET 4" PVCTEE 4" PVC PLUGSCREW TYPE TEMPORARY POOL EL. 162.00' NORMAL POOL EL. 161.00' 2" DRAW DOWNORIFICE TEMPORARYPOOL 12"4" PVC PIPESTUBBED INTOOUTLET RISER 0' SCALE IN FEET 25 50 100 0' SCALE IN FEET 10 20 40NORTH BMP ELEMENT THE ENTIRE BMP POTENTIAL PROBLEM TRASH/DEBRIS IS PRESENT. HOW TO REMEDIATE THE PROBLEM REMOVE THE TRASH/DEBRIS. INSPECTION AND MAINTENANCE PROVISIONS AREAS OF BARE SOIL AND/OREROSIVE GULLIES HAVE FORMED. ESTABLISHED. PROVIDE LIME AND A ONE-GROUND COVER AND WATER UNTIL IT ISREMOVE THE GULLY, AND THEN PLANT AREGRADE THE SOIL IF NECESSARY TO TIME FERTILIZER APPLICATION. THE PERIMETER OFTHE WET DETENTIONBASIN THE PIPE IS CLOGGED.THE INLET DEVICE:PIPE OR SWALE UNCLOG THE PIPE. DISPOSE OF THESEDIMENT OFF-SITE. EROSION IS OCCURRING IN THESWALE. TURF MATTING OR RIPRAP TO AVOIDCONTROL DEVICES SUCH AS REINFORCEDSMOOTH IT OVER AND PROVIDE EROSIONREGRADE THE SWALE IF NECESSARY TO FUTURE PROBLEMS WITH EROSION. THE FOREBAY SEDIMENT HAS ACCUMULATED TOA DEPTH GREATER THAN THEORIGINAL DESIGN DEPTH FOR POSSIBLE. REMOVE THE SEDIMENT ANDSEDIMENT AND REMEDY THE PROBLEM IFSEARCH FOR THE SOURCE OF THE EROSION HAS OCCURRED. THE PLANTS RATHER THAN SPRAYING.HAND. IF PESTICIDE IS USED, WIPE IT ONREMOVE THE WEEDS, PREFERABLY BYWEEDS ARE PRESENT. THE VEGETATEDSHELF PLANTS. PROVIDE A ONE-TIME FERTILIZERETC. REMEDY THE PROBLEM AND REPLACEPROBLEM: SOILS, HYDROLOGY, DISEASE,DETERMINE THE SOURCE OF THE APPLICATION TO ESTABLISH THE GROUNDCOVER IF A SOIL TEST INDICATES IT ISNECESSARY. BEST PROFESSIONAL PRACTICESSHOW THAT PRUNING IS NEEDED THE MAIN TREATMENTAREA DISPOSE OF IT IN A LOCATION WHERE ITPOSSIBLE. REMOVE THE SEDIMENT ANDSEDIMENT AND REMEDY THE PROBLEM IFSEARCH FOR THE SOURCE OF THE WILL NOT CAUSE IMPACTS TO STREAMS ORTHE BMP. SEDIMENT HAS ACCUMULATED TOA DEPTH GREATER THAT THE AND CONTROL THE ALGAL GROWTH.CONSULT A PROFESSIONAL TO REMOVEALGAL GROWTH COVERS OVER50% OF THE AREA. TOO LONG.VEGETATION IS TOO SHORT OR MAINTAIN VEGETATION AT A HEIGHT OFAPPROXIMATELY SIX INCHES. OTHERWISE DAMAGED.THE PIPE IS CRACKED OR REPLACE THE PIPE. THE BMP.WILL NOT CAUSE IMPACTS TO STREAMS OR DISPOSE OF IT IN A LOCATION WHERE ITSEDIMENT STORAGE. EROSION PROBLEMS.RIPRAP IF NEEDED TO PREVENT FUTURESUCH AS REINFORCED TURF MATTING ORPROVIDE ADDITIONAL EROSION PROTECTION TO MAINTAIN OPTIMAL PLANTHEALTH. PRACTICES.PRUNE ACCORDING TO BEST PROFESSIONAL PLANTS ARE DEAD, DISEADED ORDYING. THE PLANTS RATHER THAN SPRAYING.HAND. IF PESTICIDE IS USED, WIPE IT ONREMOVE THE WEEDS, PREFERABLY BYWEEDS ARE PRESENT. ORIGINAL DESIGN SEDIMENTSTORAGE DEPTH. WITH PESTICIDE (DO NOT SPRAY).REMOVE THE PLANTS BY WIPING THEMCATTAILS, PHRAGMITES OR OTHERINVASIVE PLANTS COVER 50% OFTHE BASIN SURFACE. THE EMBANKMENT REMOVE SHRUBS IMMEDIATELY.SHRUBS HAVE STARTED TO GROWON THE EMBANKMENT. BEAVERS.CONSULT A PROFESSIONAL TO REMOVEUSE TRAPS TO REMOVE MUSKRATS ANDEVIDENCE OF MUSKRAT ORBEAVER ACTIVITY IS PRESENT. REMOVE THE TREE.CONSULT A DAM SFETY SPECIALIST TOA TREE HAS STARTED TO GROWON THE EMBANKMENT. MAKE ALL NEEDED REPAIRS.AN ANNUAL INSPECTION BY ANAPPROPRIATE PROFESSIONALSHOWS THAT THE EMBANKMENTNEEDS REPAIR. OF THE SEDIMENT OFF-SITE.CLEAN OUT THE OUTLET DEVICE. DISPOSECLOGGING HAS OCCURRED.THE OUTLET DEVICE THE OUTLET DEVICE IS DAMAGED. REPAIR OR REPLACE THE OUTLET DEVICE. THE RECEIVING WATER THE 401 OVERSIGHT UNIT, 919-733-1786.QUALITY WASHINGTON REGIONAL OFFICE, OR CONTACT THE NC DIVISION OF WATERDAMAGE HAVE OCCURRED AT THEEROSION OR OTHER SIGNS OF OUTLET. WET POND PLAN VIEW SCALE: 1" = 30' WET POND PROFILE VIEWSCALE: 1" = 50' HORZ. 1"= 5' VERT. CONSTRUCTION SEQUENCE FOR WET DETENTION POND: 1. INSTALL EROSION CONTROLS2. CONSTRUCT DAM BASE AND AREAS BELOW THE NORMAL POOL. CONSTRUCTION TO BEPERFORMED UNDER THE INSPECTION OF THE GEOTECHNICAL ENGINEER. SEED UPONCOMPLETION3. INSTALL OUTLET PIPE, RIPRAP APRON AND STONE FILTER RING.4. CONSTRUCT OUTLET STRUCTURE, INSTALL TEMPORARY SKIMMER.5. UPON COMPLETION AND STABILIZATION OF UPSTREAM DEVELOPMENT, REMOVESKIMMER, INSTALL PERMANENT ORIFICE DRAWDOWN DEVICE AND SEED UPONCOMPLETION. NOTE: STORMWATER PONDS ARE TO BE CONSTRUCTED FOR USEAS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION.ONCE CONSTRUCTION IS COMPLETED THE TEMPORARYSEDIMENT BASIN IS TO BE CLEANED UP AND SHAPEDPRIOR TO BE USED AS A STORMWATER POND. NOTE: 1. CONTRACTOR TO PROVIDE A PEAKED ROOF STRUCTURE TRASHRACK BY PLASTIC SOLUTIONS INC. (877-87775727) OREQUIVALENT. 6" x 6" MAXIMUM GRATE OPENING 2. PROVIDE STEPS IN ALL DRAINAGE STRUCTURES DEEPER THAN 54".LOCATE STEPS WITHIN REASONABLE PROXIMITY TO ACCESS POINT(MANHOLE OR GRATE OPENING) WITHOUT INTERFERING WITHPIPE ORIENTATIONS. TRASH RACKSEE MANUFACTURERSSPECIFICATIONS FORDETAILS4" PVC PIPE FOR DRAWDOWN ORIFICEINV = 161.00'SEE DETAIL ~ WET POND ~ TOP OF RIM = 162.00' 15" RCPINV OUT =160.00' TRASH RACK BY PLASTICSOLUTIONS INC. OREQUIVALENT 2'-2" X 3.0'PRECAST BOX 4' MINKEY 1 1 3' MIN. CUTOFF TRENCHAPPROXIMATE SIZEEXCAVATE AND BACKFILL WITHCOMPACTED FILL AS DIRECTEDBY GEOTECHNICAL ENGINEER SCALE: N.T.S. CUTOFF TRENCH - OUTFALL DETAIL 6.5' X 6.5' CONC.ANTI- SEEPAGECOLLARSEE DETAIL 6" TOPSOIL ABOVE6" CLAY LINER ONLITTORAL SHELF CONCRETE SHALL BEPLACED IN RISER AFTERANGLES ARE SECURE TOBASE AND RISER ELEV. = 158.00' 3' X 4' CONC. BASE REINFORCED WITH#4 BARS AT 12" O.C. TOP AND BOTTOM OFEACH DIRECTION. PROVIDE 3" MINCLEARANCE BETWEEN EDGE OF CONCRETEAND STEEL REINFORCING. SCALE: N.T.S. TYPICAL VEGETATIVE SHELF DETAIL POND NORMAL POOL SHALLOW LAND ZONEHERBACEOUS PLANTS 6 1 WATER LEVEL LOW POINT PUMPFLOW FLO W SCALE: N.T.S. INFILTRATION BASIN DEWATERING NOTES:1) PRIOR TO INSTALLATION, MANUFACTURER SPECIFICATIONSOF FILTER MEDIA SHALL BE REVIEWED TO ENSURE THATDISCHARGE FROM FILTER MEDIA SHALL MEET OR EXCEEDTHE PROVISIONS OF THE CLEAN WATER ACT.2) ENSURE THAT PUMP PRESSURE DOES NOT EXCEED FILTERMEDIA PRESSURE RATING.3) FILTER MEDIA MAY BE, BUT NOT LIMITED TO, SAND MEDIAFILTRATION PRACTICES.4) PUMP STRAINER SHALL NOT BE IN CONTACT WITH BOTTOMOF POND. SCALE: N.T.S. CONCRETE ANTI- SEEPAGE COLLAR 6.5' 3.25' 3.25' 6.5' 12" #4 REBAR @12" OCIN FRONT & REAR FACEOF COLLAR. REBAR TOHAVE 3" MIN. CONC. COVERFROM EDGE OF FACE OF COLLAR NOTES:1) ALL CONCRETE TO BE 3000 PSINON-FLY ASH2) APPLY 1/2" THICK WRAP OFASPHALTIC CEMENT AROUNDDISCHARGE PIPE 6" BEYOND PLANNEDSEEPAGE COLLAR ON BOTH SIDES3) APPLY ADDITIONAL ASPHALTICCEMENT AT PIPE/SEEPAGE COLLARINTERFACE ON UPSTREAM FACES4) TO BE FIELD INSPECTED BYGEOTECHNICAL ENGINEER. ASPHALTICCEMENT TO MEET OR EXCEEDFEDERAL SPECIFICATION SS-153 TYP1:ASTM-D-2822-75 TYPE 1. SCALE: N.T.S. VEGETATIVE SHELF PLANTINGS: AREA OF VEGETATIVE SHELF: 2,846 SFMIN. PLANTS REQUIRED: 712 PLANT TYPE: SCIENTIFIC NAME:COMMON NAME:QUANTITY: NURSERY CONTAINER: SPACING: PLANTING SEASON: EUPATORIADELPHUS MACULATUS SPOTTED TRUMPETWEED 238 PEAT POT 6' O.C. SPRING/SUMMEREUPATORIUM PURPUREUM JOE-PYE WEED 238 PEAT POT 6' O.C. SPRING/SUMMERRHYNCHOSPORA COLORATA STARRUSH WHITETOP 238 PEAT POT 6' O.C. SPRING/SUMMER STORM WATER MANAGEMENT NOTES: 1. THE DEVELOPER OR HIS AGENT SHALL CONTACT THE DESIGN ENGINEER WHENTHE BEST MANAGEMENT PRACTICES ARE CONSTRUCTED AND ABOUT TO BECOMEOPERATIONAL SO THAT A FINAL INSPECTION CAN BE PERFORMED TO DETERMINECOMPLIANCE WITH THE APPROVED PLAN.2. ANNUAL MAINTENANCE INSPECTION AND REPORT REQUIRED. THE OWNER OF APERMITTED STRUCTURAL STORM WATER BMP SHALL ANNUALLY SUBMIT AMAINTENANCE AND INSPECTION REPORT FOR EACH BMP TO THE STORM WATERADMINISTRATOR. ANNUAL INSPECTIONS SHALL BEGIN WITHIN ONE YEAR OF THERECORDATION OF ANY DEED(S) SHOWING STORM WATER BMPS.3. UPON COMPLETION OF THE PROJECT, THE ENGINEER OF RECORD SHALL CERTIFYTHAT THE COMPLETED PROJECT IS IN ACCORDANCE WITH THE APPROVED STORMWATER MANAGEMENT PLANS AND DESIGNS.4. A FINAL INSPECTION OF THE SITE AND STORM WATER BMP SHALL BE SCHEDULEDWITH AND COMPLETED BY THE PROJECT ENGINEER.5. NCDEQ AND THEIR ASSIGNS HAVE RIGHT TO ACCESS THE STORM WATERCONTROLS FOR INSPECTIONS OR MAINTENANCE AS NECESSARY.6. THE PROPERTY OWNER IS RESPONSIBLE FOR MAINTAINING THE STORM WATERCONTROLS ACCORDING TO THE APPROVED MAINTENANCE PLAN AND DIRECTIONOF NCDEQ. BMP LANDSCAPE NOTES: 1. THE BMP LANDSCAPING SHALL BE IN COMPLIANCE WITH THE NCDEQ BMPREQUIREMENTS.2. LANDSCAPE CONTRACTOR SHALL PROVIDE A TWO-YEAR WARRANTY PERIOD. ALLPLANTS THAT DO NOT SURVIVE MUST BE REPLACED.3. AT THE END OF THE FIRST YEAR AND AT THE END OF THE TWO-YEAR WARRANTYPERIOD, ALL PLANTS THAT DO NOT SURVIVE MUST BE REPLACED.4. ESTABLISHMENT PROCEDURES SUCH AS CONTROL OF INVASIVE WEEDS, ANIMALAND VANDAL DAMAGE, MULCHING, AND WATERING SHALL BE IMPLEMENTED TOTHE EXTEND NEEDED TO ENSURE PLANT SURVIVAL.5. SOD WITHIN BMP AND SURROUNDING AREAS TO BE CENTIPEDE GRASS.6. GRASS OR WILDFLOWER SEED MUST BE APPLIED AT THE RATES SPECIFIED BY THESUPPLIERS. IF PLANT ESTABLISHMENT CANNOT BE ACHIEVED WITH SEEDING BYTHE TIME OF SUBSTANTIAL COMPLETION OF THE STORM WATER FACILITY PORTIONOF THE PROJECT, THEN THE CONTRACTOR SHALL PLANT THE AREA WITHWILDFLOWER SOD, PLUGS, CONTAINER PLANTS, OR OTHER MEANS TO COMPLETETHE SPECIFIED PLANTING AND PROJECT AGAINST EROSION BEFORE WATER ISALLOWED TO ENTER THE STORM WATER BMP FACILITY.7. ALL MATERIALS SHALL BE ACQUIRED FROM AN APPROVED NCDEQ PLANT VENDOR.PLANT MATERIAL SHOULD BE PURCHASED FROM A LOCAL SOURCE TO ENSURESURVIVABILITY.8. IMMEDIATELY AFTER THE WET DETENTION BASIN IS ESTABLISHED, THE PLANTS ONTHE VEGETATED SHELF AND PERIMETER OF THE BASIN SHOULD BE WATERED TWICEWEEKLY IF NEEDED UNTIL THE PLANTS BECOME ESTABLISHED (COMMONLY SIXWEEKS).9. NO PORTION OF THE WET DETENTION POND SHOULD BE FERTILIZED AFTER THEFIRST INITIAL FERTILIZATION THAT IS REQUIRED TO ESTABLISH THE PLANTS ON THEVEGETATED SHELF.10. BMP PLANT SUBSTITUTIONS ARE NOT PERMITTED.11. ONLY NON-CLUMPING TURF GRASSES SHALL BE USED. TREES AND WOODY SHRUBSSHALL NOT BE ALLOWED ON THE DAM OR TOP OF SLOPE AREA/10' MAINTENANCEAREA OF THE BMP. BMP MAINTENANCE: Important operation and maintenance procedures: 1. Immediately after the wet pond is established, the plants on the vegetated shelfand perimeter of the basin will be watered twice weekly if needed, until theplants become established (commonly six weeks).2. No portion of the wet pond will be fertilized after the first initial fertilizationthat is required to establish the plants on the vegetated shelf.3. Stable ground cover will be maintained in the drainage area to reduce thesediment load to the wet pond.4. If the pond must be drained for an emergency or to perform maintenance, theflushing of sediment through the emergency drain will be minimized as much aspossible.5. Once a year, a dam safety expert should inspect the embankment.6. The measuring device used to determine the sediment elevation shall be suchthat it will give an accurate depth reading and not readily penetrate intoaccumulated sediments. After the wet pond is established, it should be inspected quarterly and within 24 hoursafter every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County)..Records of operation and maintenance will be kept in a known set location and shallbe available upon request.Inspection activities shall be performed as follows. Any problems that are found shallbe repaired immediately. 1,045.52'617.23'98.46'W- 2W- 3 77.85'W- 4 W-1RCP906.62'N 88°01'02" E 715.69' TOTALOHU OHUC1L2L1OHUL3HAYES ROAD - NCSR 204760' PUBLIC RIGHT-OF-WAY (PAVED)C2L4OHURCPPHONE PEDESTAL C3TIEN 02°18'21" E30.00'OHU WATERVALVETIES 89°18'20" E 136.53'S 02°48'51" W 1.075.54' TOTAL N 02°18'21" E 1,014.47' TOTALRCP RCPRCPRCP RCPRCP16" GRAVITY FEEDSANITARY SEWER EXISTING SOIL DRIVE EXISTING 40' UTILITY EASEMENT 20' EITHER SIDE OF CENTER OF UTILITIES - DETERMINED BY CLEARING LIMITS - IRON 3/4IRON 3/4 DELINATED WETLAND 5,183 SF(ELEV = 158.1') EX NAIL IN PINE KNOT FOUND IN WET AREA APPROXIMATE LOCATIONOF FEMA FLOOD ZONE ZONE AE BASE FLOOD ELEVETION = 158.9' EX. DRAINAGE CHANNEL >> EXISTING GRAVEL DRIVE EX 30' ACCESS EASEMENT PLAT BOOK 98, PG 271 EXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF 16" GRAVITY FEED SANITARY SEWER 16" GRAVITY FEED SANITARY SEWEREXISTING 30' UTILITY EASEMENT15' EITHER SIDE OF UTILITY- DETERMINED BY CLEARING LIMITS - EX. SANITARYFORCE MAIN 30' SEWEREASEMENT 6" WATER LINE PER GISEX. DRAINAGE CHANNEL IRON 5/8" N:548092.95E:2025804.67 N:548128.77 E:2025101.13 RCPEX. OVERHEADPOWER LINE SSMH RIM = 168.60 INV = 147.66 SSMHRIM = 168.50INV = 148.06 SSMH RIM = 168.85 INV = 148.45 SSMH RIM = 168.08 INV = 148.98 SSMH RIM = 127.27INV = 149.22 SSMHRIM = 173.39INV = 149.29 W W W W W W WWWWWWWWW W W SSSSSSSSSSSSSSSSSSSSSSSSSSSSOPEN SPACESS SS SS SS SS SS SS SS SS SS SS SS SS SSSSOPEN SPACE 4 13726 SF 0.32 Ac 5 13948 SF 0.32 Ac 6 13983 SF 0.32 Ac 7 14019 SF0.32 Ac 8 14053 SF0.32 Ac 9 14003 SF 0.32 Ac 10 13962 SF 0.32 Ac 11 13894 SF0.32 Ac 12 13894 SF 0.32 Ac 13 13894 SF0.32 Ac 14 13894 SF 0.32 Ac 15 13894 SF 0.32 Ac 16 12008 SF 0.28 Ac 17 12000 SF 0.28 Ac 18 12000 SF 0.28 Ac 19 12000 SF 0.28 Ac 20 12000 SF 0.28 Ac 21 12000 SF 0.28 Ac 30 12829 SF 0.29 Ac 29 12033 SF 0.28 Ac 28 12000 SF 0.28 Ac 27 12000 SF 0.28 Ac 26 12000 SF0.28 Ac 25 12000 SF 0.28 Ac 24 12000 SF 0.28 Ac 23 12000 SF 0.28 Ac 22 12041 SF0.28 ACc 3,944 SF 1 15897 SF 2 15876 SF 3 15880 SF 0.09 Ac 35 12000 SF 0.28 Ac 36 12369 SF 0.28 AcOPEN SPACE8,576 Sq. Feet0.20 AcOPEN SPACE24,168 Sq. Feet0.55 Ac34 12000 SF 0.28 Ac 33 12000 SF 0.28 Ac 32 12000 SF 0.28 Ac 31 12000 SF 0.28 Ac 113,337 SF2.60 AcWWWWWWWWWW W W W WWW W156160158168167166165164163162156157 161160159158 167166165164163162156158168161RED MAPLE(TYP) JAPANESE HOLLY(TYP) PRIVET(TYP) RED MAPLE(TYP) RED MAPLE(TYP) JAPANESE HOLLY(TYP) PRIVET(TYP) RED MAPLE(TYP) RED MAPLE(TYP) LANDSCAPEEASEMENT 10' LANDSCAPEEASEMENT (TYP.) 10' LANDSCAPEEASEMENT 30' LANDSCAPEEASEMENT 30' LANDSCAPEEASEMENT NORTH LANDSCAPE PLAN AND DETAILL 1.0 NOTE: 1. CONTRACTOR TO REGRADE, SOD OR HYDROSEED, AND STRAW MULCH ALL AREAS DISTURBED AS A RESULT OF HIS/HER WORK. 2. UPRIGHT STAKES TO BE USED ON TREES UP TO 12' IN HEIGHT. LARGER TREES MUST BE GUYED. 3. 1/8 OF ROOT BALL TO BE ABOVE FINISHED GRADE. 4. DO NOT COVER CROWN OF ROOT BALL EVERGREEN TREES WHICH ARE TIGHTLY SPACED SHALL BETIED TOGETHER IN ONE CONTINUOUS BED. (CONTRACTOR TO INCLUDE THIS MULCHING IN HIS/HER BID) 5. TREES WHICH ARE LOCATED WITHIN 4 FEET OF AN ADJACENT SHRUB BED SHALL HAVE THEIRMULCHED AREA CONNECTED WITH THE MULCHED BED OF THE SHRUBS. 6. PRUNE AND REMOVE BROKEN OR DEAD LIMBS/BRANCHES FROM TREES AND SHRUBS AFTERPLANTING. RETAIN NATURAL SHAPE OF PLANT. NOTE: 1. BEDS TO HAVE SMOOTHLY CONTOURED AND CLEANLY DEFINED EDGES. BEDS SHALL CURVILINEAR EXCEPT AS NOTED ON PLAN. 2. PROPOSED BEDS MUST BE LAID OUT ON SITE AND APPROVED BY OWNER, IF REQUESTED BY OWNER. 3. REMOVE TOP 1/3 OF ALL BURLAP FABRIC AROUND ROOT BALL. 4. COMPLETELY REMOVE ALL STRINGS, RIBBONS, AND TABS FROM THE PLANT. 5. SCARIFY ROOTS ON POT BOUND PLANTS. 6. PLANT SPACING VARIES - (SEE PLAN) 7. ALL SHRUBS TO BE PLANTED IN MULCHED BEDS.8. PRUNE ALL BROKEN, DISEASED, AND WEAK BRANCHES. 9. ALL SHRUB BEDS TO BE COMPLETELY EXCAVATED OF ALL EXISTING SOIL TO REQUIRED DEPTH AND BACKFILLED WITH REQUIRED SOILMIX. 10. SOIL MIX: 2/3 TOPSOIL & 1/3 ORGANIC MATTER. 11. TOP DRESS BED WITH 10-6-4 FERTILIZER AT THE RATE OF 5 LBS. PER 100 S.F. OF BED AREA. GENERAL NOTES: 1.1 THIS PLAN IS FOR LANDSCAPE PURPOSES ONLY. LANDSCAPE PLAN PROVIDED IS FOR MINIMUM COMPLIANCE WITH HARNETT COUTY UDO AND SHOULD NOT BECONSIDERED AN ENHANCED LANDSCAPE PLAN. CONSULT WITH A REGISTERED LANDSCAPE ARCHITECT FOR SPECIFIC PLANTING RECOMMENDATIONS. 1.2 UNDERGROUND UTILITIES HAVE NOT BEEN VERIFIED BY THE OWNER, LANDSCAPE ARCHITECT, OR THEIR REPRESENTATIVES. PLEASE CALL BEFORE YOU DIG. 1.3 THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE RESPONSIBLE FOR ANYAND ALL DAMAGES WHICH MIGHT RESULT FROM THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY UNDERGROUND UTILITIES TO REMAIN. 1.4 THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO ENSURE THAT THE NEW WORK SHALL FIT INTO THE EXISTING SITE IN THE MANNER INTENDED AND ASSHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE OWNER'SREPRESENTATIVE PRIOR TO PERFORMING ANY WORK IN THE AREA INVOLVING DISCREPANCIES. NOTIFICATION SHALL BE MADE IN THE FORM OF A DRAWING ORSKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATING TO THE AREA. 1.5 ALL WORK SHALL MEET OR EXCEED THE REQUIREMENTS OF ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES AND REQUIREMENTS. 1.6 IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PERFORM ALL WORK IN A MANNER THAT PROTECTS COMPLETED WORK BY OTHERS, SUCH AS CURBS,UTILITIES, STORM DRAINAGE, FENCES, DRIVEWAY APRONS, DRIVES, VEGETATION, ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF SATISFACTORYREPAIR OF ALL DAMAGES IN KIND RESULTING FROM HIS/HER FAILURE TO COMPLY. 1.7 THE CONTRACTOR IS TO VERIFY ALL QUANTITIES SHOWN ON THE PLAN AND IN THE PLANT SCHEDULE. IF DISCREPANCIES OCCUR, THE CONTRACTOR SHALLCONTACT THE LANDSCAPE ARCHITECT IMMEDIATELY. QUANTITIES OF PLANTS SHOWN BY LANDSCAPE SYMBOLS SHALL GOVERN OVER THE QUANTITIES SHOWN INTHE PLANT SCHEDULE. 1.8 ALL MATERIALS SHALL BE SUBJECT TO APPROVAL BY THE LANDSCAPE ARCHITECT. THE OWNER SHALL RECEIVE TAGS FROM EACH PLANT SPECIES AND A LIST OFPLANT SUPPLIERS. WHERE ANY REQUIREMENTS ARE OMITTED FROM THE PLANT LIST, THE PLANTS FURNISHED SHALL MEET THE NORMAL REQUIREMENTS FOR THEVARIETY OR CULTIVAR PER THE AMERICAN STANDARD FOR NURSERY STOCK, LATEST EDITION, PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN).PLANTS SHALL BE PRUNED PRIOR TO DELIVERY ONLY UPON THE APPROVAL OF THE LANDSCAPE ARCHITECT. 1.9 NO SUBSTITUTIONS OF PRODUCTS, PLANT TYPES OR SIZES SHALL BE MADE WITHOUT WRITTEN APPROVAL OF THE OWNER, LANDSCAPE ARCHITECT, ANDMUNICIPAL REVIEW AGENCY. REQUESTS FOR SUBSTITUTION SHALL BE IN WRITING, AND SHALL STATE THE REASONS FOR THE SUBSTITUTION REQUEST, THESUGGESTED ALTERNATIVE, AND THE CHANGES IN COST. REQUESTS FOR SUBSTITUTION IN PLANT MATERIAL SHALL STATE THE NAMES OF NURSERIES WHO HAVE BEENUNABLE TO SUPPLY THE ORIGINALLY SPECIFIED MATERIAL. 1.10PLANTING SHALL ONLY OCCUR DURING SPECIFIED PLANTING SEASONS. SPRING SEASON SHALL BE FROM MARCH 1 TO JUNE 15. FALL PLANTING SEASON SHALL BEFRO SEPTEMBER 15 TO NOVEMBER 15. 1.11 THE CONTRACTOR SHALL GUARANTEE ALL LANDSCAPE IMPROVEMENTS, INCLUDING SEEDING, FOR ONE FULL YEAR AS REQUIRED BY THE SPECIFICATIONS. THECONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL PLANT MAINTENANCE DURING THE GUARANTEE PERIOD. 1.12INSTALLED UNIT PRICES FOR ALL PLANT MATERIAL SHALL BE SUPPLIED TO THE OWNER AND LANDSCAPE ARCHITECT AT THE TIME OF BIDDING. 1.13 THE LANDSCAPE CONTRACTOR IS TO PERFORM A THOROUGH CLEANUP AND QUALITY CONTROL INSPECTION WITHIN 12 HOURS PRIOR TO THE OPENING OF THEPOOL. 1.14 THE LANDSCAPE CONTRACTOR IS SUBJECT TO RANDOM INSPECTIONS BY THE OWNER AND/OR THE OWNER'S REPRESENTATIVE AT ANY TIME DURING THEINSTALLATION PROCESS. Know what's belowCall before you dig.Dial 811Or Call 800-632-4949 1 2 3417 Winterwind Circle, Sanford, NC 27330PO Box 249, Sanford, NC 27331Phone: (919) 352-2834e-mail: jhilliard@hilliardengineering.comNC License #: P-0836DESIGNED BY: DRAWN BY: APPROVED BY: SHEET: CIVIL NO.REVISION DESCRIPTION:DATE:ENGINEERING, PLLCHILLIARDJEH - JEHHAYES POINTESPRING LAKE, NORTH CAROLINAPRELIMINARY - FOR REVIEW ONLY - NOT FOR CONSTRUCTIONNORTHVICINITY MAP BUDDYBAREFOOT RD2049 BETHEL BAPTIST RD2048 HAYES RD2047 BILLSHAW RD1144 NOT TO SCALE SITE 0' SCALE IN FEET 30 60 120 TREE/SHRUB PLANT LIST:BOTANICAL NAME: SIZE: COUNT:SYMBOL: RED MAPLE ACER RUBRUM 2" CAL., 6' HT. 92 JAPENESE HOLLY ILEX CRENATA 'HOOGENDORN' 2" CAL., 6' HT. 56 PRIVET LIGUSTRUM JAPONICUM 3 GAL.110 ALL STREET TREES SHALL BE AT LEAST TWO (2) INCHES IN CALIPER AND A MINIMUM OF SIX (6) FEET IN HEIGHT AT THE TIME OF PLANTING. STREET TREES SHALL BE PLANTED IN A LINEAR ARRANGEMENT PARALLEL TO THE STREET NO LESS THAN FIVE (5) FEET AND NO MORE THAN 10 FEET OUTSIDE THE RIGHT-OF-WAY. STREET TREES SHALLBE PLANTED AT LEAST EIGHT (8) FEET FROM UTILITY POLES AND 10 FEET FROM ELECTRICALTRANSFORMERS. KEEP MULCH AWAYFROM TRUNK MULCH, MIN.DEPTH OF 4" 3" MIN. - 6" MAX.TOP OF BALL FINISHED GRADE BOTTOM OF BALL BOTTOM OF PIT 6" MIN ROOTBALL, ASNOTED UNDISTURBED NATIVESOIL PEDESTAL 2.5 X BALL DIA.(MIN.) 6" MIN. HIGH NATIVESOIL SAUCER NATIVE SOILBACKFILL 12" MIN FINISHED GRADE SET SHRUB PLUMB SHRUB PLANTING SCALE: N.T.S. PLANT BED:NATIVE SOIL BACKFILL,DEPTH AS NOTED FINISHED GRADE ANDTOP OF PLANT BEDEQUAL "X" MIN 2/3 "X" MIN MULCH, DEPTH ASNOTED INCREASE DEPTH OF MULCHAS DETAILED, AT EDGE OFALL PLANTING BEDS. FINISHED GRADE OFLAWN OR WALK 'X' ASNOTED PLANT BED EDGING DETAIL SCALE: N.T.S. KEEP MULCH AWAYFROM TRUNK MULCH, MIN.DEPTH OF 4" 3" MIN. - 6" MAX.TOP OF BALL FINISHEDGRADE BOTTOM OF BALL BOTTOM OF PIT 6" MIN ROOTBALL, ASNOTED UNDISTURBED NATIVESOIL PEDESTAL 2.5 X BALL DIA.(MIN.) 6" MIN. HIGH NATIVESOIL SAUCER NATIVE SOILBACKFILL WOOD OR METALSTAKES 12" MIN FINISHEDGRADE RUBBER HOSES GUY WIRES, WITHTURNBUCKLES SET TREE PLUMB SHADE AND UNDERSTORYTREE PLANTING SCALE: N.T.S. 4 BLACK FOREST DRIVE BOOKRAND LANESTEPPING STONE LANE