HomeMy WebLinkAboutCameron Commercial_site plansNC 24-87SCOTTSCOTTCHRIS1766NOT TO SCALEVICINITY MAPANDERSON CREEK TOWNSHIPSPOUT SPRINGS, NORTH CAROLINAHARNETT COUNTYINDEX OF DRAWINGSG1.0 - UTILITY NOTESC1.0 - EXISTING CONDITIONSC2.0 - SITE PLANC3.0 - EROSION CONTROL PLANC3.1 - GRADING & DRAINAGE PLANC3.2 - DRAINAGE AREA MAPC4.0 - UTILITY PLANC5.0 - C5.1 - PROFILESC6.0 - SITE DETAILSC6.1 - EROSION CONTROL DETAILSC6.2 - EROSION CONTROL DETAILSC6.3 - EROSION CONTROL DETAILSC6.4 - EROSION CONTROL DETAILSC6.5 - WATER & SEWER DETAILSC6.6 - STORM DETAILSCAMERON COMMERCIALSITE DEVELOPMENT PLANSTHE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATEDARCHITECTURENA ARCHITECTURE, PA212 Powell Drive-Suite 100Raleigh, NC 27606919-852-2329Contact: Steven Urenaemail: urena.arch@gmail.comOWNER/DEVELOPERHMD CONSTRUCTION & DEVELOPMENT8204 Creedmoor Road, Suite 100Raleigh, NC 27613919-274-6443Contact: Kenneth Dickinsonemail: kenneth@hmddevelopment.comSURVEYOR4D SITE SOLUTIONS, INC.409 Chicago Drive - Suite 112Fayetteville, North Carolina 28306910-426-6777Contact: Jimmy Holland, PLSemail: jholland@4dsitesolutions.comCIVIL ENGINEER4D SITE SOLUTIONS, INC.409 Chicago Drive - Suite 112Fayetteville, North Carolina 28306910-426-6777Contact: Scott Brown, PEemail: sbrown@4dsitesolutions.comKnow what'sbelow.before you dig.CallRSEALL-4571SEAN R.SEEVE
R
NO
R
T
H CAROLINAPR
O
FESSIONALLAND SURVE
YOR SEAL027452N
O
R
T
H CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEER
I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l 00 CS l 3.17.2022 3:11:53 PM
CAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEDATE RELEASEDSEE SHEETSPROJECT NAMECLIENTPROJECT INFORMATIONDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022TAX ID# 9594-26-3582.000 &9594-26-4447.000NC 24/87ANDERSON CREEKTOWNSHIPSPOUT SPRINGSHARNETT COUNTYNORTH CAROLINASITEEXISTING UTILITY OWNERWATER ANDHARNETT REGIONAL WATER700 McKinney ParkwayLillington, North Carolina 27546910-893-7575Contact: Glenn McFadden
SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEER
I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l 01 G1.0 NOTES l 3.17.2022 2:59:16 PM
UTILITY NOTESCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEG-1.0SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDSEE SHEETSDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 20221.”2.”3.”“”“”“””””¾”””””””””””””¾”””””“””””“”“””””””””””“””
4531NC 24-87314315316317318319320321321322323325325324320315310325330331
327328329326324323322321319318317316314313312311309308324320316
31532032031531231331531431531632032532
7
32
8
326
3
2
9
330
330325
320316325320320320320329 SITEVICINITY MAPNOT TO SCALEI:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C1.0 EX l 3.17.2022 2:57:30 PM
EXISTINGCONDITIONSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEDATE SURVEYEDHORIZONTAL: 1"=30'C-1.0SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSURVEYED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:CLIFFSEANJIMMY1766SEALL-4571SEAN R.SEEVE
R
NO
R
TH CAROLINAPR
O
FESSIONALLAND SURVE
YORDECEMBER 21, 202117MARCH17MARCHSEALL-4571SEAN R.SEEVER NORTH CAROLINAPROFESSIONALLAND SURVEYOR
4 D S ITE
SOLUTIONSNC GRID NAD 83 (2011)325322
4531NC 24-87VICINITY MAPNOT TO SCALEHORIZONTAL: 1"=30'I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C2.0 SITE l 3.17.2022 5:15:56 PM
SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERSITE PLANCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-2.0SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022SITE4 D S ITE
SOLUTIONSNC GRID NAD 83 (2011)325322SITE DATA
4531NC 24-87314315316317318319320321321322323325325324320315310325330331
327328329326324323322321319318317316314313312311309308324320316
31532032031531231331531431531632032532
7
32
8
326
3
2
9
330
330325
320316325320320320320329
SD3253263273273243223203183173193213223243203273273
27
32732732
6 327327327328328328328329329328328
330
32932
7
328
326
329
326
327 323
321320325322320325325323322321325322323321325
321
323
3
2
6
327329330329
331
327325325324322328326327325
326
327 VICINITY MAPNOT TO SCALETHE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATEDKnow what'sbelow.before you dig.CallRI:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C3.0 G&EC l 3.17.2022 5:17:23 PM
HORIZONTAL: 1"=30'SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEEREROSIONCONTROL PLANCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-3.0SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022SITE4 D S IT
E
SOLUTIONSNC GRID NAD 83 (2011)325322
4531NC 24-87314315316317318319320321321322323325325324320315310325330331
327328329326324323322321319318317316314313312311309308324320316
31532032031531231331531431531632032532
7
32
8
326
3
2
9
330
330325
320316325320320320320329
SD3253263273273243223203183173193213223243203273273
27
32732732
6 327327327328328328328329329328328
330
32932
7
328
326
329
326
327 323
321320325322320325325323322321325322323321325
321
323
3
2
6
327329330329
331
327325325324322328326327325
326
327 VICINITY MAPNOT TO SCALETHE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATEDKnow what'sbelow.before you dig.CallRI:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C3.1 G&EC l 3.17.2022 5:16:41 PM
HORIZONTAL: 1"=30'SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERGRADING ANDDRAINAGE PLANCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-3.1SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022SITE4 D S IT
E
SOLUTIONSNC GRID NAD 83 (2011)325322
4531NC 24-87314315316317318319320321321322323325325324320315310325330331
327328329326324323322321319318317316314313312311309308324320316
31532032031531231331531431531632032532
7
32
8
326
3
2
9
330
330325
320316325320320320320329
SD3253263273273243223203183173193213223243203273273
27
32732732
6 327327327328328328328329329328328
330
32932
7
328
326
329
326
327 323
321320325322320325325323322321325322323321325
321
323
3
2
6
327329330329
331
327325325324322328326327325
326
327 VICINITY MAPNOT TO SCALETHE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATEDKnow what'sbelow.before you dig.CallRI:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C3.2 DA l 3.17.2022 5:12:05 PM
HORIZONTAL: 1"=30'SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERDRAINAGE AREAMAPCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-3.2SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022SITE4 D S IT
E
SOLUTIONSNC GRID NAD 83 (2011)325322
4531NC 24-87314315316317318319320321321322323325325324320315310325330331
327328329326324323322321319318317316314313312311309308324320316
31532032031531231331531431531632032532
7
32
8
326
3
2
9
330
330325
320316325320320320320329
SD3253263273273243223203183173193213223243203273273
27
32732732
6 327327327328328328328329329328328
330
32932
7
328
326
329
326
327 323
321320325322320325325323322321325322323321325
321
323
3
2
6
327329330329
331
327325325324322328326327325
326
327 VICINITY MAPNOT TO SCALETHE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATEDKnow what'sbelow.before you dig.CallRI:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C4.0 UT l 3.17.2022 5:15:05 PM
HORIZONTAL: 1"=30'SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERUTILITY PLANPIN#CAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-4.0SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022SITE4 D S ITE
SOLUTIONSNC GRID NAD 83 (2011)325322
STORM DRAIN -0+50 TO 5+00DI-1 TO PO-7STORM DRAIN -0+50 TO 1+00RI-8 TO FES-9320
324
323
322
321
319
3183173163233
2
1
320 3253223203
2
5 321325324322 325326 327327327326327328
33
03273
2
8
32932
6 329330330SD327327 327
328 328
329328 328330329327325
322
325321323329330329331327326 327
I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C5.0 PRO l 3.17.2022 5:18:51 PM
HORIZONTAL: 1"=30'VERTICAL: 1"=3'SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERSTORMPROFILESCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-5.0SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 20224
D SITE SOLUTIONSNC
G
R
I
D
N
A
D
8
3
(
2
0
1
1
)4D SITE SOLUTIONSNC GR
ID
N
AD
83
(
2
0
1
1
)4D SITE SOLUTIONSNC GRID NAD 83 (2011)
STORM DRAIN -0+50 TO 2+50WET POND 1324320315325330327329326324323322321319318317316SD329
326
327 323
321320325322320325325323322321325322323321325321323 326327329330329327 325325324322328326327SANITARY SEWER -0+50 TO 1+00SEWER LATERALWATER MAIN -0+50 TO 0+50FIRE HYDRANT31631731632032
5320316325320320320320329
326319322320327
3
2
7
319320321321322323315 316
320
325
325320316
32
5
320320320320
32932532
6327319322320I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C5.1 PRO l 3.17.2022 5:19:48 PM
HORIZONTAL: 1"=30'VERTICAL: 1"=3'SEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERSTORM & UTILITYPROFILESCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-5.1SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 20224 D SITE
S
OLUTIONSNC G
RI
D
N
A
D
8
3 (
2
0
1
1)
4D SIT
E
SOLUTIONSNC GR
I
D
N
A
D
8
3
(
2
0
1
1
)4D SITE SOLUTIONSN
C
G
R
I
D
N
A
D
8
3
(
2
0
1
1
)
159126234871011I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C6.0 DET l 3.17.2022 5:33:56 PM
NOT TO SCALESEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERSITE DETAILSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-6.0SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022LIGHT DUTY PAVEMENTNTSHEAVY DUTY PAVEMENTNTSCONCRETE DRIVE PAVEMENT SECTIONNTSTURN DOWN SIDEWALKNTSCONCRETE WHEEL STOPNTS6" BOLLARDNTSDUMPSTER PADNTSHANDICAP SIGNAGE AND PAVEMENT MARKINGSNTSSECTION A-ASECTION B-BISOMETRIC VIEWPLAN VIEWHANDICAP RAMP WITH TRUNCATED DOMESNTSTRUNCATED DOMESSHRUB PLANTINGNTSTREE PLANTINGNTS24" CURB & GUTTERNTSSPILL TYPECARRY TYPE SPILL TYPECARRY TYPE
172 3465910I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C6.1 DET l 3.17.2022 3:06:05 PM
NOT TO SCALESEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEEREROSIONCONTROLDETAILSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-6.1SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022TEMPORARY SEEDING/MULCHING SPECIFICATIONS (FOR SUMMER)SEEDING MIXTURE:SPECIES RATE (LB./ACRE)GERMAN MILLET 40A SMALL-STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB./ACRE.SEEDING DATES:MAY 1 - AUGUST 15SOIL AMENDMENTS:FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB./ACRE GROUND AGRICULTURAL LIMESTONE AND 750LB./ACRE 10-10-10 FERTILIZER.MULCH:APPLY 4,000 LB./ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL.A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL.MAINTENANCE:REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWINGEROSION OR OTHER DAMAGE.TEMPORARY SEEDING/MULCHING SPECIFICATIONS (FOR FALL)SEEDING MIXTURE:SPECIES RATE (LB./ACRE)RYE (GRAIN) 120SEEDING DATES:AUGUST 15 - DECEMBER 30SOIL AMENDMENTS:FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB./ACRE GROUND AGRICULTURAL LIMESTONE AND1,000 LB./ACRE 10-10-10 FERTILIZER.MULCH:APPLY 4,000 LB./ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL.A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL.MAINTENANCE:REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB./ACRE OF NITROGEN IN MARCH. IFIT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB./ACRE KOBE LESPEDEZAIN LATE OR EARLY MARCH.TEMPORARY SEEDING/MULCHING SPECIFICATIONS (FOR LATE WINTER AND EARLY SPRING)SEEDING MIXTURE:SPECIES RATE (LB./ACRE)RYE (GRAIN) 120ANNUAL KOBE LESPEDEZA 50OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT EXTEND BEYOND JUNE.SEEDING DATES:JANUARY 1 - MAY 1SOIL AMENDMENTS:FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB./ACRE GROUND AGRICULTURAL LIMESTONE AND 750LB./ACRE 10-10-10 FERTILIZER.MULCH:APPLY 4,000 LB./ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL.A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL.MAINTENANCE:REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWINGEROSION OR OTHER DAMAGE.TEMPORARY SEEDING SPECIFICATIONSPERMANENT SEEDING SPECIFICATIONSSEEDING SPECIFICATIONSSEEDING MIXTURES:SPECIES RATE (LBS./ACRE)TALL FESCUE 80PENSACOLA BAHIAGRASS 50SERICEA LESPEDEZA 30KOBE LESPEDEZA 10SEEDING NOTES:1. FROM SEPT. 1 TO MAR. 1 USE UNSCARIFIED SERICEA SEED.2. ON POORLY DRAINED SITES OMIT SERICEA AND INCREASE KOBE TO 30 LB./ACRE.3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE TO 40 LB./ACRE.NURSE PLANTS:BETWEEN APRIL 15 AND AUG. 15, ADD 10 LB./ACRE OF GERMAN MILLET OR 15 LB./ACRE SUDANGRASS. PRIOR TO MAY 1OR AFTER AUG. 15, ADD 25 LB./ACRE RYE (GRAIN).SEEDING DATES: BEST POSSIBLEEARLY SPRING: FEB. 15 - MAR. 20 FEB. 15 - APR. 30FALL: SEPT. 1 - SEPT. 30 SEPT. 1 - OCT. 31SOIL AMENDMENTS:APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR APPLY 3,000 - 5,000 LB./ACRE GROUND AGRICULTURALLIMESTONE (USE THE LOWER RATE ON SANDY SOILS) AND 1,000 LB./ACRE 10-10-10 FERTILIZER.MULCH:APPLY 4,000 LB./ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BYTACKING WITH ASPHALT, NETTING, OR ROVING OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITHBLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL.MAINTENANCE:IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR, ACCORDING TO THE SOIL TESTS ORTOP DRESS WITH 500 LB./ACRE 10-10-10 FERTILIZER. MOW AS NEEDED WHEN SERICEA IS OMITTED FROM THE MIXTURE.RESEED, FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY.SEEDING SPECIFICATIONSSEEDING MIXTURE:SPECIES RATE (LB./ACRE)COMMON BERMUDAGRASS 40-80(1-2 LB./1,000 FT²)SEEDING DATES:COASTAL PLAIN: APR. - JULYSOIL AMENDMENTS:APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR APPLY 3,000 LB./ACRE GROUND AGRICULTURAL LIMESTONEAND 500 LB./ACRE 10-10-10 FERTILIZER.MULCH:USE JUTE, EXCELSIOR MATTING, OR OTHER EFFECTIVE CHANNEL LINING MATERIAL TO COVER THE BOTTOM OFCHANNELS AND DITCHES. THE LINING SHOULD EXTEND ABOVE THE HIGHEST CALCULATED DEPTH OF FLOW. ONCHANNEL SIDE SLOPES ABOVE THIS HEIGHT, AND IN DRAINAGES NOT REQUIRING TEMPORARY LININGS, APPLY 4,000LB./ACRE GRAIN STRAW AND ANCHOR STRAW BY STAPLING NETTING OVER THE TOP.MULCH AND ANCHORING MATERIALS MUST NOT BE ALLOWED TO WASH DOWN SLOPES WHERE THEY CAN CLOGDRAINAGE DEVICES.MAINTENANCE:A MINIMUM OF 3 WEEKS IS REQUIRED FOR ESTABLISHMENT. INSPECTION AND REPAIR MULCH FREQUENTLY.REFERTILIZE THE FOLLOWING APR. WITH 50 LB./ACRE NITROGEN.GENERAL EROSION AND SEDIMENT CONTROL NOTES1. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE ANDSTRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALLBE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THEMINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTHCAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK.2. THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITYONE WEEK PRIOR TO THE PRECONSTRUCTION CONFERENCE, ONEWEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBINGACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION.3. IF POSSIBLE ALL EROSION AND SEDIMENT CONTROL MEASURESARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE.4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROLPLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES.5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREASOTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOTLIMITED TO OFF-SITE BORROW OR WASTE AREAS, STAGING ORSTORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMITA SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FORREVIEW AND TO NCDENR REGIONAL OFFICE FOR APPROVAL.CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALLNECESSARY MEASURES AT NO SEPARATE PAYMENT. THECONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER ACOPY OF THE AMENDED PERMIT.6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANYADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENTEROSION AND SEDIMENTATION AS DETERMINED BY EITHER NCDENROR THE ENGINEER.7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENTCONTROL MEASURES AT ALL TIMES DURING LAND DISTURBINGACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINALSTABILIZATION IS ACHIEVED.8. ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISEIMPROVED SHALL BE SODDED OR SEEDED AS INDICATED ANDSTABILIZED.9. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPEDINTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TORECEIVING OUTLET.10. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROLMEASURES WEEKLY AND AFTER EACH RUNOFF-PRODUCING EVENT.ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THEEFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BEMADE IMMEDIATELY.11. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BEREMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENTGROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THEENGINEER. NCDENR'S FINAL APPROVAL IS REQUIRED.12. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BEREQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES ANDALL CONSTRUCTION ACCESS LOCATIONS INTO NON-PAVED AREA.13. WHEN CROSSING CREEK OR DRAINAGE-WAY, THE CONTRACTORSHALL RIP-RAP WITH FABRIC DISTURBED BANKS AND CHANNEL ANDRESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZEDIMMEDIATELY.MAINTENANCEMAINTAIN THE GRAVEL PAD INBA CONDITION TO PREVENT MUD ORSEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAYREQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. AFTER EACHRAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT ANDCLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALLOBJECTIONABLE MATERIALS SPILLED, WASHED OR TRACKED ONTOPUBLIC ROADWAYS.CONSTRUCTION VEHICLES. AVOID STEEP GRADESAND ENTRANCES AT CURVES IN PUBLIC ROADS.CONTRACTOR SHALL INSTALL ADDITIONAL GRAVEL2-3" COURSE MAINTAIN AT NO ADDITIONAL EXPENSE TO THE OWNER.REQUIRED FOR STAGING AND/OR BORROW AREAS ANDCONSTRUCTION ENTRANCES AT HIS EXPENSE UNTIL FINALCONTRACTOR SHALL SUPPLEMENT AND MAINTAIN GRAVELCONSTRUCTION ENTRANCES NOT INDICATED ON THE PLANS PUBL
IC
ROAD6" MIN. THICKNESSACCEPTANCE.1
2
'
m
i
n
.50' min.6"AGGREGATE SIZE - USE 2-3 INCH WASHED STONEWIDTH - 12 FT. MINIMUM OR FULL WIDTH AT ACCESSPOINTS OF THE VEHICULAR ENTRANCE AND EXIT LOCATION - LOCATE CONSTRUCTION ENTRANCES ANDEXITS TO LIMIT SEDIMENT FROM LEAVING THE SITEAND TO PROVIDE FOR MAXIMUM UTILITY BY ALLGRAVEL CONSTRUCTION ENTRANCEDIMENSION OF GRAVEL PADTHICKNESS - 6 INCHES MINIMUMAREA, WHICHEVER IS GREATERLENGTH - 50 FT. MINIMUM.WITH 20 FOOT RADIUS AT EXISTINGIN LENGTH AND 12 FEET IN WIDTHGRAVEL ENTRANCE SHALL BE 50 FEETDESIGN CRITERIAFILTER FABRICROADWAY36'-0" MIN2-3" WASHED STONE4'-0"10'-0"AGGREGATETEMPORARY GRAVEL CONSTRUCTION ENTRANCENTSGROUND STABILIZATION CHARTNTSMAINTENANCE:INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVESEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETSAND MAKE TIMELY REPAIRS AS NEEDED.TEMPORARY DIVERSION KEY NOTES:1. CLEAR THE ARE UNDER THE BERM AND STRIP THE ROOTS/OTHER ORGANICS.2. COMPACT THE SIDE SLOPES, PREFERABLY WITH A TRACKED VEHICLE TO SLOW RUNOFF VELOCITIES.3. VEGITATE THE RIDGE OF THE BERM IMMEDIATELY AFTER CONSTRUCTION UNLESS THE BERM WILL REMAIN IN PLACE FOR LESS THAN 30 DAYS.TEMPORARY DIVERSION BERMNTSMAINTENANCEINSPECT TEMPORARY SEDIMENT BASINS WEEKLY AND AFTER EACH PERIOD OFSIGNIFICANT RAINFALL. REMOVE SEDIMENT AND RESTORE TRAP TO ITS ORIGINALDIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGNDEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN AN AREA WITHSEDIMENT CONTROLS.CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE ANDINSPECT THE EMBANKMENT FORPIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVEALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL AREA.TEMPORARY SEDIMENT BASINNTSCONSTRUCTION SPECIFICATIONS1. CLEAR, GRUB & STRIP TOPSOIL FROM AREAS UNDER THE EMBANKMENT TOREMOVE TREES, VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL.DELAY CLEARING THE POOL AREA UNTIL THE DAM IS COMPLETE AND THENREMOVE BRUSH, TREES, AND OTHER OBJECTIONABLE MATERIALS TO FACILITATESEDIMENT CLEANOUT. STOCKPILE ALL TOPSOIL OR SOIL CONTAINING ORGANICMATTER FOR USE ON THE OUTER SHELL OF THE EMBANKMENT TO FACILITATEVEGETATIVE ESTABLISHMENT. PLACE TEMPORARY SEDIMENT CONTROLS BELOWTHE BASIN AS NEEDED.2. EXCAVATE CUT-0FF TRENCH ALONG THE CENTER LINE OF THE EARTH FILLEMBANKMENT. CUT THE TRENCH TO STABLE SOIL MATERIAL, BUT IN NO CASEMAKE IT LESS THAN 2 FEET DEEP. THE CUT-OFF TRENCH MUST EXTEND INTOBOTH ABUTMENTS TO AT LEAST THE ELEVATION OF THE RISER CREST. MAKETHE MINIMUM BOTTOM WIDTH WIDE ENOUGH TO PERMIT OPERATION OFEXCAVATION AND COMPACTION EQUIPMENT, BUT IN NO CASE LESS THAN 2 FEET.MAKE SIDE SLOPES OF THE TRENCH NO STEEPER THAN 1:1. COMPACTIONREQUIREMENTS ARE THE SAME AS THOSE FOR THE EMBANKMENT. KEEP THETRENCH DRY DURING BACKFILLING AND COMPACTION OPERATIONS.3. EMBANKMENT - TAKE FILL MATERIAL FROM THE APPROVED AREAS SHOWN ONTHE PLANS. IT SHOULD BE CLEAN MINERAL SOIL, FREE OF ROOTS, WOODYVEGETATION, ROCKS, AND OTHER OBJECTIONABLE MATERIAL. SCARIFY AREASON WHICH FILL IS TO BE PLACED BEFORE PLACING FILL. THE FILL MATERIALMUST CONTAIN SUFFICIENT MOISTURE SO IT CAN BE FORMED BY HAND INTO ABALL WITHOUT CRUMBLING. IF WATER CAN BE SQUEEZED OUT OF THE BALL, IT ISTOO WET FOR PROPER COMPACTION. PLACE FILL MATERIAL IN 6 TO 8 INCHCONTINUOUS LAYERS OVER THE ENTIRE LENGTH OF THE FILL AREA ANDCOMPACT IT. COMPACTION MAY BE OBTAINED BY ROUTING THE CONSTRUCTIONHAULING EQUIPMENT OVER THE FILL SO THAT THE ENTIRE SURFACE OF EACHLAYER IS TRAVERSED BY AT LEAST ONE WHEEL OR TREAD TRACK OF HEAVYEQUIPMENT, OR A COMPACTOR MAY BE USED. CONSTRUCT THE EMBANKMENTTO AN ELEVATION 10% HIGHER THAN THE DESIGN HEIGHT TO ALLOW FORSETTLING.4. SECURELY ATTACH THE RISER TO THE BARREL OR BARREL STUB TO MAKE AWATERTIGHT STRUCTURAL CONNECTION. SECURE ALL CONNECTIONS BETWEENBARREL SECTIONS BY APPROVED WATERTIGHT ASSEMBLIES. PLACE THEBARREL AND RISER ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DONOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE ASBACKFILL AROUND THE PIPE OR ANTISEEP COLLARS. PLACE THE FILL MATERIALAROUND THE PIPE SPILLWAY IN 4 INCH LAYERS, AND COMPACT IT UNDER ANDAROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENTEMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM FIRMCONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPEHAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILLOVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTIONEQUIPMENT. ANCHOR THE RISER IN PLACE BY CONCRETE OR OTHERSATISFACTORY MEANS TO PREVENT FLOTATION. IN NO CASE SHOULD THE PIPECONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THEEMBANKMENT IS COMPLETE.5. INSTALL THE EMERGENCY SPILLWAY IN UNDISTURBED SOIL. THEACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, ANDENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFULOPERATION OF THE EMERGENCY SPILLWAY.6. DISCHARGE THE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION.USE DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT-LADENWATER TO THE UPPER END OF THE POOL AREA TO IMPROVE TRAP EFFICIENCY.7. CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED.DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THEEMBANKMENT BEFORE THE AREA IS CLEARED.8. INSTALL POROUS BAFFLES AS SPECIFIED.9. AVOID STEEP SIDE SLOPES, AND FENCE AND MARK BASINS WITH WARNINGSIGNS IF TRESPASSING IS LIKELY. FOLLOW ALL STATE AND LOCALREQUIREMENTS.NOTES1. SEED AND PLACE MATITNG FOR EROSION CONTROL ON INTERIOR ANDEXTERIOR SIDESLOPES.2. INSTALL A MINIMUM OF 3 COIR FIBER BAFFLES IN ACCORDANCE WITH PRACTICESTANDARD 6.65.3. INSTALL SKIMMER AND COUPLING TO RISER STRUCTURE OR DIRECTLY INTOEMBANKMENT 1 FT. FROM BOTTOM OF BASIN.4. THE ARM PIPE SHALL HAVE A MINIMUM LENGTH OF 6 FT. BETWEEN THESKIMMER AND COUPLING.MAINTENANCEINSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER)RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDEADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUTTHE WIRE MESH DURING THE SEDIMENT REMOVAL. REPLACE STONE AS NEEDED.HARDWARE CLOTH & GRAVEL INLET PROTECTIONNTSSILT FENCEAA #9 WIRE STAPLES 1-1/2" LONGMIN. 12-1/2 GA.LINE WIRES MIN. 12-1/2 GASTAY WIRES MIN. 10 GA. WIRETOP & BOTTOM STRAND ATTACH WIRE FENCE TO POSTS AND EXTENDDRIVE STEEL POSTS 18" INTO THE GROUNDSTEP 2FENCE. BURIED FABRIC SHALL NOT BE VISIBLE.FIRMLY TO ANCHOR THE BOTTOM OF THE SILT BACKFILL THE TRENCH AND COMPACT THE SOILEXCAVATED TRENCH AND TURNED OUTTHE BOTTOM OF THE FENCE 8" INTO THESTEP 4EXCAVATED TRENCH & TURNEDBOTTOM OF WIRE FENCE ANDFILTER FABRIC BURIED 8" INWIRE FENCE "HOG WIRE"FILTER FABRICPOSTS MAX 8' O.C.STEP 1STEP 3EXTEND THE BOTTOM OF THE FABRIC 8" INTO THE TRENCH AND TURNED OUT 4" IN THE TRENCH.ATTACH THE FILTER FABRIC TO THE WIRE FENCE,TRENCH UPHILL ALONG THE LINE OFPOSTS.MAXIMUM 8' O.C. AND EXCAVATE A 4" X 8"FLOWSECTION A-ASTEEL POST DRIVEN 24" INTO GROUNDHEIGHT MAX 18"STEEL POSTSOUT 4" IN THE TRENCH4" IN THE TRENCH.NOTES:1. WIRE SHALL BE A MINIMUM OF 32 INCHES IN WIDTH ANDSHALL HAVE A MINIMUM OF 6 WIRES WITH 12" STAY SPACING.2. FILTER FABRIC SHALL BE A MINIMUM OF 36" IN WIDTH ANDSHALL BE FASTENED ADEQUATELY TO THE WIRE WITH #9 WIRESTAPLES 1-1/2" LONG. FABRIC THAT DETERIORATES TO SUCHEXTENT THAT IT'S EFFECTIVENESS IS REDUCED SHALL BEREPLACED BY CONTRACTOR AT CONTRACTOR'S EXPENSE.3. STEEL POSTS SHALL BE A MIN. OF 5' HEIGHT AND SHALL BETHE SELF FASTENER ANGLE STEEL TYPE.4. CONTRACTOR SHALL REVIEW SILT FENCE ONCE PER WEEKAND AFTER EACH RAINFALL OCCURRENCE. ANY NECESSARYREPAIRS OR CLEAN-UP TO MAINTAIN THE EFFECTIVENESS OFTHE DEVICE SHALL BE MADE IMMEDIATELY.5. REMOVE DEPOSITED SEDIMENT ALONG THE FENCE TOPROVIDE ADEQUATE STORAGE VOLUME AND TO REDUCEPRESSURE ON THE FENCE AS NEEDED.5. TEMPORARY MEASURE SHALL NOT BE REMOVED BY THECONTRACTOR UNTIL THIS ACTION IS APPROVED BY AN NCDENRREPRESENTATIVE. THE ACTION WILL BE APPROVED WHEN THECONTRIBUTING DRAINAGE AREA IS STABLE.MAINTENANCE1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY.2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY.3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCEPRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT.4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE AFTERTHE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED AND NCDENR APPROVES REMOVAL.NTSBOTTOM OF FABRIC BURIED 8"IN EXCAVATED TRENCH &TURNED OUT 4" IN THETRENCH, OR PINNED WITH 8"EROSION CONTROL MATTINGSTAPLES.SUPPORT WIRE ORROPEBACKFILL THE TRENCH AND COMPACT THE SOILFIRMLY TO ANCHOR THE BOTTOM OF THE SILTFENCE. BURIED FABRIC SHALL NOT BE VISIBLE.THE TOP OF THE FABRIC SHALL BE 6" HIGHERTHAN THE WEIR.ATTACH THE JUTE NETTING OR OTHER FABRICAPPROVED BY THE ENGINEER TO THE STAY WIREAND POSTS, EXTEND THE BOTTOM OF THE FABRIC8" INTO THE TRENCH AND TURNED OUT 4" IN THETRENCH OR USE 8" EROSION CONTROL MATTINGSTAPLES.ATTACH WIRE FENCE TO POSTS AND EXTENDTHE BOTTOM OF THE FENCE 8" INTO THEEXCAVATED TRENCH AND TURNED OUT 4" INTHE TRENCH.DRIVE POSTS 24" INTO THE GROUNDMAXIMUM 4' O.C. AND EXCAVATE A 4" X 8"TRENCH UPHILL ALONG THE LINE OFPOSTS.NOTES:1. GRADE THE BASIN SUCH THAT THE BOTTOM IS LEVEL2. INSTALL THE BAFFLES AS SHOWN ON THE GRADING PLAN.BAFFLES SHALL EXTEND THE FULL WIDTH OF THE BASIN.3. DO NOT SPLICE THE FABRIC, USE A CONTINUOUS PIECEACCROSS THE BASIN OR TRAP.4. POSTS FOR THE BAFFLES SHALL BE 4' OC.MAINTENANCE1. INSPECT THE BAFFLES EACH ACTIVE DAY ON SITE BUT INNO CASE LESS THAN ONCE PER WEEK AND AFTER EACHRAINFALL EVENT. MAKE ANY REPAIRS IMMEDIATELY.2. REMOVE SEDIMENT DEPOSITS WHEN THE MEASUREREACHES HALF FULL. TAKE CARE TO AVOID DAMAGING THEBAFFLES WHEN THE SEDIMENT IS REMOVED.3. TEMPORARY MEASURE SHALL NOT BE REMOVED BY THECONTRACTOR UNTIL THIS ACTION IS APPROVED BY ANNCDENR REPRESENTATIVE. THE ACTION WILL BEAPPROVED WHEN THE CONTRIBUTING DRAINAGE AREA ISSTABLE.4. PLACEMENT OF BAFFLES: INLET ZONE- 35% OF LENGTH FROM ENTRY POINT FIRST CELL - 25% OF LENGTH FROM INLET ZONE SECOND CELL - 25% OF LENGTH FROM FIRST CELL OUTLET ZONE - 15% OF LENGTH FROM SECOND CELLSTEEL POSTSHEIGHT MAX 18"24" INTO GROUNDSTEEL POST DRIVEN SECTION A-AFLOWSTEP 3STEP 1POSTS MAX 4' O.C.JUTE NETTING OR EQUIVILENTTOP STAY WIRE OR ROPESTEP 4STEP 2AAPERSPECTIVE VIEWPOROUS BAFFLESNTSTYPICAL RIP RAP APRONNTSSECTION A-APLANSILT FENCE OUTLETNTSSECTION VIEWMAINTENANCE NOTES:1. REMOVE THE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDEADEQUATE VOLUME FOR THE NEXT RAIN AND TO REDUCEPRESSURE ON THE FENCE/OUTLET. TAKE CARE TO AVOIDUNDERMINING THE FENCE DURING CLEANOUT. REMOVE &REPLACE STONE AS NECESSARY AS IT BECOMES CLOGGED WITHSEDIMENT.2. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENTDEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE ITAFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLYSTABILIZED.FRONT VIEWNOTES:1. INSTALL SILT FENCE PER STD. SILT FENCE DETAIL.2. LOCATE REINFORCED OUTLET AT LOW POINTS OF SILT FENCE BARRIER.3. PLACE RIP RAP WITH CARE. DO NOT TEAR SILT FENCE FABRIC.81112
52376910I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C6.2 DET l 3.17.2022 5:36:25 PM
NOT TO SCALESEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEEREROSIONCONTROLDETAILSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-6.2SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 20228NTSVEGETATED SHELF PLANTING DETAIL0.7 STAPLES PER SQ. YD.(0.8 STAPLES PER SQ. M)1.3 STAPLES PER SQ. YD.(1.5 STAPLES PER SQ. M)3.6 STAPLES PER SQ. YD.(4.3 STAPLES PER SQ. M)(4.1 STAPLES PER SQ. M)3.4 STAPLES PER SQ. YD.4.00' [1.22M]4.00' [1.22M]2.00' [0.61M]8.00' [2.44M]4.00' [1.22M]3.00' [0.91M]3.00' [0.91M]1.50' [0.46M]2.00' [0.61M]4.00' [1.22M]2.00' [0.61M]2.00' [0.61M]4.00' [1.22M]1.00' [0.30M]2.00' [0.61M]1.50' [0.46M]3.00' [0.91M]1.50' [0.46M]2.00' [0.61M]4.00' [1.22M]4.00' [1.22M]STAPLE PATTERN FOR 4' ROLLSNTSEROSION CONTROL BLANKET INSTALLATIONNTSMAINTENANCE:1. INSPECT THE EROSION CONTROL BLANKET ONCE A WEEK AND AFTER EVERY RAINFALL.2. IMMEDIATELY REPAIR AND/OR REPLACE ANY DAMAGED BLANKET.3. IF GROUND COVER IS NOT ESTABLISHED THROUGH THE BLANKET WITHIN 2 WEEKS, THE BLANKETSHOULD BE REMOVED AND THE AREA RESEEDED. AFTER RESEEDING, THE BLANKET SHOULD BEREINSTALLED.13B3A452GABION BAFFLEGABION SPECIFICATIONSMATERIALGABIONS SHALL BE MADE OF WELDED STEEL WIRE MESH OF ANOMINAL SIZE OF 3” X 3”. THE WELDED STEEL WIRE SHALL BE PVCCOATED IN ALL APPLICATIONS PERTAINING TO THE GABION.DIMENSIONSGABIONS SHALL BE BUILT IN VARIOUS LENGTHS AND HEIGHTS. THELENGTH SHALL BE IN MULTIPLESOF THE WIDTH. THE WIDTH SHALL NOT BE LESS THAN 3'. DIMENSIONSFOR HEIGHTS, WIDTHS AND LENGTHS ARE SUBJECT THE APPLICATIONAND PURPOSE. IF THE LENGTH IS INCREASED BY A MULTIPLE OF THEWIDTH THE BASKET SHALL HAVE A WIRE WALL DIAPHRAGM SEWN INTOITS INTERIOR TO MAINTAIN THE SHAPE OF THE BASKET.FABRICATIONGABIONS SHALL BE FABRICATED IN SUCH AWAY THAT THE BASE, SIDES,LIDS, ENDS, AND DIAPHRAGMS CAN BE ASSEMBLED AT THECONSTRUCTION SITE INTO A RECTANGULAR UNIT OF THE SPECIFIEDSIZE. THE LID SHALL BE A SEPARATE UNIT OF THE SAME MESH ANDWIRE SPECIFICATIONS AS THE BODY. THE WELD SHEAR STRENGTHSHALL COMPLY WITH ASTM A-185-90A. WHERE THE LENGTH OF THEGABION EXCEEDS ITS WIDTH, THE GABION SHALL BE DIVIDED BYDIAPHRAGMS INTO CELLS OF EQUAL LENGTH. THE WIRE MESH SHALLBE MADE OF GALVANIZED STEEL WIRE HAVING A MINIMUM DIAMETEROF 3 MM. ALL WIRE USED IN THE FABRICATION OF THE GABION AND INTHE WIRING OPERATIONS SHALL CONFORM TO US FEDERALSPECIFICATION QQ-W-461H AND POSSESS A SOFT TENSILE STRENGTHWITH A CLASS 3 FINISH 5 ZINC COATING IN ACCORDANCE WITH ASTMA-641. PREFORMED STEEL WIRE SPIRAL BINDERS WITH A 3” PITCH AREUSED TO ASSEMBLE AND INTERCONNECT EMPTY GABIONS AND SHALLMEET THE SAME SPECIFICATION AS THE WIRE USED IN THE MESH.AFTER ASSEMBLY, THE INDIVIDUAL GABION UNITS AREINTERCONNECTED USING THE SAME WIRE AND THE CONNECTIONSHOULD BE MADE NO LESS THAN EVERY 6” ALONG THE PERIMETER.THEY SHOULD THEN FILLED WITH CLEAN, HARD STONE FROM 4” - 8”INDIAMETER. THE LIDS ARE THEN CLOSED AND JOINED TO THE TOPEDGES OF THE INDIVIDUAL GABIONS AND DIAPHRAGMS. THE USE OFEXPEDIENT CLIPS OR HOG RINGS FOR THIS PURPOSE IS NOTPERMITTED.IF PROPERLY CONSTRUCTED, THE LIDS AND PANELS SHOULD MEETCLOSELY WITHOUT GAPS AND THAT THE TIES PROVIDE A TIGHT JOINTAT ALL PANELS AND DIAPHRAGMS.NTSGABION INSPECTION AND MAINTENANCEGABIONS REQUIRE LITTLE MAINTENANCE. GABIONS CAN REMAIN ASPERMANENT STRUCTURES AFTER CONSTRUCTION PHASES ARECOMPLETE.·INSPECT REGULARLY AND AFTER STORM EVENTS·INSPECT FOR UNDERCUTTING AND OTHER SIGNS OF STABILITY·INSPECT WIRE BASKETS AND MATTRESSES FOR SIGNS OFDEGRADATION, RUST AND BREAKAGE.·REPAIR OR REPLACE IMMEDIATELY TO MAINTAIN ENGINEEREDPERFORMANCE STANDARDS.FAIRCLOTH SKIMMERNTSROCK PIPE INLET PROTECTIONNTSFL
O
W FLOWFLOW
#57 WASHED STONE1' THICK X 3' HIGH MIN.CLASS 1 RIP RAP HEADWALLCLASS 1 RIP RAP(SEE SECTION THRU BASIN BELOW)CONSTRUCTION SPECIFICATIONS:1. CLEAR THE AREA OF ALL DEBRIS.2. INSTALL THE CLASS B OR CLASS I RIPRAP IN A SEMI-CIRCLE AROUNDTHE PIPE INLET.3. A 1 FOOT THICK LAYER OF NCDOT #5 OR #57 STONE SHOULD BEPLACED ON THE OUTSIDE SLOPE OF THE RIPRAP.4. SEDIMENT STORAGE AREA SHOULD BE EXCAVATED AROUND THEOUTSIDE OF THE STONE HORSESHOE 18" BELOW NATURAL GRADE.5. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, FILLDEPRESSION AND ESTABLISH FINAL GRADING ELEVATIONS, COMPACT,AND STABILIZE WITH GROUND COVER.SEDIMENTSTORAGEFLOODSTORAGEZONEPIPE INVERTRIP RAP HEADWALLNATURAL GROUNDFILTER FABRICMAX. SEDIMENT DEPTH(CLEAN OUT POINT)#57WASHEDSTONECLASS 1 RIP-RAPSECTION THRU BASIN, FILTER, & CULVERT PIPENOT TO SCALESEDIMENT STORAGE AREAPERSPECTIVE VIEWNOT TO SCALEFLOWFLOWMAINTENANCE:INSPECT ROCK PIPE INLET PROTECTION AT LEAST WEEKLY AND AFTEREACH SIGNIFICANT (1/2" OR GREATER) RAINFALL EVENT AND REPAIRIMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENTSTORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HASACCUMULATED TO 1/2 THE DESIGN DEPTH OF THE TRAP. PLACE THESEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA ANDREPLACE THE CONTAMINATED PART OF THE GRAVEL FACING.CHECK THE STRUCTURE FOR DAMAGE. ANY RIPRAP DISPLACED FROMTHE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY.ANTI-SEEP COLLARNTSEMERGENCY SPILLWAYNTS1. INSTALL THE EMERGENCY SPILLWAY IN UNDISTURBED SOIL. THE ACHIEVEMENTOF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXITCHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THEEMERGENCY SPILLWAY.2. ALTERNATIVE MATERIALS MAY BE USED OTHER THAN THE SPECIFIED STONE IFAPPROVED BY THE DESIGN ENGINEER.3. MAX SIDE SLOPES ARE 3:1TRASH RACKNTSSTORM BASIN RISER WITH ORIFICE DETAILNTS14
I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C6.3 DET l 3.17.2022 3:06:39 PM
NOT TO SCALESEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEEREROSIONCONTROLDETAILSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-6.3SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022
1034879I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C6.4 DET l 3.17.2022 3:06:50 PM
NOT TO SCALESEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERWATER & SEWERDETAILSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-6.4SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 202261115GENERAL WATERLINE NOTES1. CONTRACTOR SHALL REPAIR ALL WATER LATERALS, AND MAINS DAMAGED DURING CONSTRUCTION.THE CONTRACTOR SHALL REPORT IMMEDIATELY ALL WATER MAIN AND LATERAL BREAKS TO HARNETTCOUNTY DISPATCHER AND TO THE OWNER'S REPRESENTATIVE AND SHALL INITIATE IMMEDIATE REPAIRSTO HARNETT COUNTY STANDARDS. CONTRACTOR SHALL NOT OPERATE HARNETT COUNTY WATER MAINVALVES WITHOUT HARNETT COUNTY APPROVAL AND SHALL COORDINATE ALL VALVE CLOSINGS WITH THEHARNETT COUNTY WATER AUTHORITY. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH WATERSYSTEM IN THE AREA SO AS TO LESSEN THE CHANCE OF SERVICE INTERRUPTION.2. THE CONTRACTOR SHALL NOT USE HOUSE HOSE BIBBS OR ANY OTHER METHOD OF BLOW OFF WHICHALLOWS DOMESTIC WATER CONTAINING SEDIMENTS OR HIGH LEVELS OF CHLORINE TO PASS THRURESIDENT'S METERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES RESULTING FROMALLOWING "DIRTY" WATER TO ENTER RESIDENT'S PLUMBING SYSTEM, SUCH AS WATER HEATERS, STAINEDCLOTHING, CLOGGED SCREENS, ETC.WATER UTILITY NOTESTYPICAL VALVE BOX DETAILNTSMETER BOX DETAIL FOR 2" SERVICENTS31"18"BAAELEVATIONELEVATION PLAN27 3/4"40 3/4"18"17 1/2"30 1/2"ABS PLASTICNOTES:1. LID SHALL BE PLACED ONMETERBOX WITH AMR PORTIONON STREETSIDE OF SERVICE.2. ALL LIDS SHALL BE CASTIRON AND APPROVED BYHARNETT COUNTY PRIOR TOINSTALLATION.D
D
10.123.3031.2341.02515.255.800R1.949.250Ø2.0-1° DRAFT/SIDE Ø6.810Ø2.0.868+10°1.6515.3114.1532 PL.30310.068B A
ASECTION D-DSCALE 2 : 1SECTION B-BSECTION A-AISOMETRIC VIEWB 4.153METER BOX AMR LIDNTSFIRE HYDRANT ASSEMBLY INSTALLATIONNTSTYP. TAPPING SLEEVE & VALVE ASSEMBLYNTSTYPICAL 2" METER BOX INSTALLATIONNTSTYPICAL VALVE MARKER DETAILNTSSANITARY SEWER(0'-8' DEPTH)PIPE LAYINGCONDITION "A"PIPEO.D.HAND PLACEDDENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPEBEDDED PIPEMINIMUM STONEEMBEDMENT ASINDICATED. GREATER IFREQUIRED BYMANUFACTURER12 PIPEO.D.24" + O.D. MAX.12" + O.D. MIN.D/8≥3"D/4D/2D/8≥3"24" + O.D. MAX.12" + O.D. MIN.12 PIPEO.D.MINIMUM STONEEMBEDMENT ASINDICATED. GREATER IFREQUIRED BYMANUFACTURERBEDDED PIPEHAND PLACEDDENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPEPIPEO.D.SANITARY SEWER(<8'-16' DEPTH)PIPE LAYINGCONDITION "B"SHAPED STONETO PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARRELSHAPED STONETO PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARRELPIPE LAYING CONDITIONNTSSANITARY SEWER(DUCTILE IRON ONLY)(0'-16' DEPTH)PIPE LAYINGCONDITION "C"PIPEO.D.HAND PLACEDDENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPEBEDDED PIPE12 PIPEO.D.24" + O.D. MAX.12" + O.D. MIN.D/2D/8≥3"24" + O.D. MAX.12" + O.D. MIN.12 PIPEO.D.MINIMUM STONEEMBEDMENT ASINDICATED. GREATER IFREQUIRED BYMANUFACTURERBEDDED PIPEHAND PLACEDDENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPEPIPEO.D.SANITARY SEWER(DUCTILE IRON ONLY)(>16' DEPTH)PIPE LAYINGCONDITION "D"SHAPED SUBGRADETO PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARRELSHAPED STONETO PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARRELPIPE LAYING CONDITIONNTSNOTE:FORCE MAINS 8"Ø AND SMALLER SHALLHAVE MINIMUM OF 3' COVER. FORCEMAINS LARGER THAN 8"Ø SHALL HAVE AMINIMUM OF 3'-6" COVER.ELECTRONIC MARKER BALLS AT 100' ONCENTER & AT BENDS. MARKER BALLS SHALLBE INSTALLED AT 1 1/2 TO 2' DEEP.1/2 PIPE O.D.24" + O.D. MAX.12" + O.D. MIN.PIPEO.D.SHAPED SUBGRADESHALL PROVIDE BEARINGALONG ENTIRE LENGTHOF PIPE BARRELBEDDED PIPEUNDISTURBED EARTHNOTE: MARKER BALLS SHALL BE INSTALLEDCONCURRENTLY WITH PIPE. MARKERBALLS SHALL NOT BE INSTALLED AFTERTRENCH HAS BEEN COMPLETELYBACKFILLED.HAND PLACEDDENSELY COMPACTEDBACKFILL TO 1 FT.ABOVE TOP OF PIPEFORCE MAINPIPE LAYINGCONDITION "E"NOTE: PIPE SHALL BE BEDDED UP TOSPRING LINE AND MINIMUM 4" BELOWBOTTOM OF PIPE WHEN WET AREAS AREENCOUNTERED.PIPE LAYING CONDITIONNTS4" PVC VERTICAL4" SWEEP WYESERVICE LINESANITARY SEWERMAINTEE BRANCHSLOPE MIN. 1%PLUGSTOP AT R/W45°SANITARY TEE(SAME MATERIALAS MAIN)CLEANOUT PLUG AND CAPNOTE:EASEMENT SHALL BE PROVIDED FOR SERVICECONNECTION WHERE SERVICE CONNECTION IS PLACEDOUTSIDE OF R/W DUE TO PHYSICAL CONSTRAINTS.CAST IRON VALVE BOXW/ CHARLOTTE HUB 3'-0"MAX.1' insideRWIN-LINE WYEFITTING FOR NEWCONSTRUCTION ORROMAC-CB SADDLEFOR TAP ON EXISTINGSANITARY SEWER MAIN.BRASS(DO NOT GLUE)SCH 40 PVC VERTICALSCH 40 PVCSCH 40 PVCSEWER SERVICE CONNECTIONNTS212
I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C6.5 DET l 3.17.2022 3:08:06 PM
NOT TO SCALESEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERSTORM DETAILSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-6.5SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 20222
I:\HMD Construction & Development\1766-Cameron Commercial\CIVIL 3D\DWG\1766-DESIGN.dwg l C6.6 DET l 3.17.2022 3:07:52 PM
NOT TO SCALESEAL027452NO
R
TH CAROLINAPR
O
FESSIONALC.SCOTT BROWNENGINEERSTORM DETAILSCAMERONCOMMERCIAL8204 Creedmoor Road - Suite 100Raleigh, North Carolina 27613Phone:(919) 791-4631REVISIONSDRAWING SCALEC-6.6SHEET NUMBERPROJECT NAMECLIENTPROJECT INFORMATIONSCOTTSCOTTCHRIS1766DATE RELEASEDDESIGNED BY:DRAWN BY:CHECKED BY:PROJECT NUMBER:MARCH 17, 2022