Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout2021-10-20 Retreat at North Main PreliminaryCivil Engineering:
SCALE: 1" = 1000'
VICINITY MAP
RETREAT AT NORTH MAIN
N
The Curry Engineering Group, PLLC
NC License # P-0799
PO Box 2018
205 S. Fuquay Ave
Fuquay-Varina, NC 27526
919.552.0849 (o)
919.880.9857 (m)
Contact: Don Curry, PE
don@curryeng.com
Developer:
HARNETT COUNTY, NORTH CAROLINA
MAJOR SUBDIVISION - PRELIMINARY PLAN
HARNETT COUNTY
SITE
DRAWING INDEX
C0.0 COVER SHEET
C0.1 CIVIL NOTES
C1.0 EXISTING CONDITIONS PLAN
C2.0 MASTER DEVELOPMENT PLAN
C2.1 PARTIAL SITE LAYOUT I
C2.2 PARTIAL SITE LAYOUT II
C2.3 PARTIAL SITE LAYOUT III
C3.0 OFFSITE FORCE MAIN PLAN
B
O
Y
K
I
N
R
D
.DATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C0.0 COVER SHEET.DWGPLOTTED: 10/20/2021 3:13 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-009MAIN ST.SIDEWALKS AND STREET TREES ARE TO BE MAINTAINED BY THE HOME OWNERS
ASSOCIATION (“HOA”), PROPERTY OWNERS ASSOCIATION (“POA”), CONDOMINIUM
OWNER'S ASSOCIATION (“COA), OR ANY OTHER ASSOCIATION RESPONSIBLE FOR
THE MAINTENANCE AND/OR UPKEEP OF THE RESIDENTIAL COMMUNITY.
SIDEWALK OR STREET TREE INSTALLATIONS THAT ARE DAMAGED AND/OR
REMOVED BY HARNETT COUNTY/ DEPARTMENT OF PUBLIC UTILITIES/HARNETT
REGIONAL WATER OR ITS REPRESENTATIVES, AGENTS, OR CONTRACTORS AS A
RESULT OF REPAIR/MAINTENANCE OF THE PUBLIC WATER AND/OR SEWER LINE
WILL BE REPLACED OR REPAIRED BY THE HOME OWNERS ASSOCIATION (“HOA”),
PROPERTY OWNERS ASSOCIATION (“POA”), CONDOMINIUM OWNER'S
ASSOCIATION (“COA), OR ANY OTHER ASSOCIATION RESPONSIBLE FOR THE
MAINTENANCE AND/OR UPKEEP OF THE RESIDENTIAL COMMUNITY.
APPROVAL OF THIS PLAT/PLAN DOES NOT GUARANTEE WATER CAPACITY OR
WASTEWATER CAPACITY. CURRENT/FUTURE CAPACITY MAY NOT BE AVAILABLE.
THIS DEVELOPMENT MAY REQUIRE ADDITIONAL IMPROVEMENTS TO THE
EXISTING WATER AND WASTEWATER SYSTEM TO MEET FUTURE WATER AND
WASTEWATER DEMANDS PRIOR TO A PRELIMINARY PLAT, CONSTRUCTION PLAN
AND/OR FINAL PLAT APPROVAL.
HARNETT COUNTY REQUIRED NOTE:
Davidson Homes, LLC
117 Centrewest Ct.
Cary, NC 27513
919-255-2602 (m)
Contact: Kim Mulder
kmulder@davidsonhomesllc.com
CORNER LOT STANDARD LOT
FRONT
REARCORNER SIDESIDESIDEROW
70'90'20'10'10'
10'25'20'
SCALE:
1
C0.0
LOT SETBACKS
N.T.S
TYPICAL BUILDING
SUBMITTED TO HARNETT COUNTY: OCTOBER 20, 2021 MAIN ST.MITCHELL RD.GREG
OR
Y
CI
R.
C0.0N.T.S.COVER SHEETNOT FOR CONSTRUCTION
SCALE:
3
C0.0
TYPICAL STREET SECTION
NTS
CUL-DE-SAC
100' PROPOSED ROW
2.5'
79' BC-BC
SLOPES
VARIES
TIE TO EXISTING
30" STANDARD
CURB & GUTTER
10.5'10.5'
TIE TO EXISTING30" STANDARD
CURB & GUTTER
74' EOP-EOP
COMPACTED
SUBGRADE
8" CABC
2%
3:1
M
A
X
.
3:1 MAX.
4.5'5'
SIDEWALK
1'
2%3:1 MA
X.
3:1
M
A
X
.
4.5'5'
SIDEWALK
1'2.5'
LC RD.
50' PROPOSED ROW
12'2.5'
29' ROADWAY
12'
2%2%
TIE TO EXISTING
2.5'
30" VALLEY CURB
& GUTTER
10.5 10.5
TIE TO EXISTING
2.5" S9.5B
4.5'5'
SIDEWALK
1'
2%
30" STANDARD
CURB & GUTTER
2%
4.5'5'
SIDEWALK
1'
8" CABCCOMPACTED
SUBGRADE
3:1 MA
X.
3:1
M
A
X
.
3:1
M
A
X
.
3:1 MAX.
SCALE:
2
C0.0
TYPICAL STREET SECTION
N.T.S
MINOR RESIDENTIAL STREET
REAR 20'FRONT 25'GOVERNING AGENCIES:
UTILITY AGENCIES:
PLANNING/ZONING/LANDSCAPE
HARNETT COUNTY
PLANNING DEPT.
108 E. FRONT STREET
LILLINGTON, NC 27546
910.893.7525 OPT. 4
CONTACT: MR. LANDON CHANDLER
EROSION CONTROL
STORMWATER
WATER & SEWER
HARNETT COUNTY PUBLIC
UTILITIES DEPT.
700 McKINNEY PARKWAY
LILLINTON, NC 27546
910.893.7575
CONTACT: MR. SHANE CUMMINGS
NCDENR-DWQ SEWER
NCDENR DIVISION OF WATER RESOURCES
FAYETTEVILLE REGIONAL OFFICE
225 GREEN STREET
SUITE 714
FAYETTEVILLE, NC 28301
910.433.3300
NCDENR-PUBLIC WATER SUPPLY
NCDENR DIVISION OF WATER RESOURCES
RALEIGH REGIONAL OFFICE
512 N. SALISBURY STREET
RALEIGH, NC 27604
919.707.9100
ENGINEERING
HARNETT REGIONAL WATER
700 McKINNEY PARKWAY
LILLINTON, NC 27546
910.893.7575
CONTACT: MR. JAY MEYERS
NCDEQ DIVISION OF ENERGY, MINERAL & LAND
RESOURCES
RALEIGH REGIONAL OFFICE
512 N. SALISBURY STREET
RALEIGH, NC 27604
919.807.6369
CONTACT: MR. JIM FARKAS
NCDEQ DIVISION OF ENERGY, MINERAL & LAND
RESOURCES
FAYETTEVILLE REGIONAL OFFICE
225 GREEN STREET
SUITE 714
FAYETTEVILLE, NC 28301
910.433.3300
NCDOT
NC DEPT. OF TRANSPORTATION
DIV. 6, DISTRICT 2
600 SOUTHERN AVENUE
FAYETTEVILLE, NC 28302
910.364.0601
CONTACT: MR. RICHIE HINES180' 2.5" S9.5B
DATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C0.1 CIVIL NOTES.DWGPLOTTED: 10/20/2021 3:13 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-0091.BOUNDARY & TOPOGRAPHY INFORMATION AS SHOWN ON THIS PRELIMINARY SUBDIVISION PACKAGE IS FROM
HARNETT COUNTY GIS DATA AND SHOULD BE CONSIDERED PRELIMINARY. A FIELD-SURVEY BOUNDARY &
TOPOGRAPHIC SURVEY IS UNDERWAY AND WILL BE UTILIZED FOR CONSTRUCTION DRAWINGS.
2.ALL WORK, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE HARNETT COUNTY STANDARDS
AND SPECIFICATIONS, LATEST EDITION.
3.ALL WORK, CONSTRUCTION AND MATERIALS WITHIN NCDOT RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH THE
2018 NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES.
4.ALL RIGHT OF WAYS SHALL BE PUBLIC.
5.THIS SITE IS LOCATED IN A FLOOD HAZARD ZONE 'X' PER FEMA MAPS 3720066000J AND 3720068000J, DATED OCT 3,
2006.
6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ZONE TRAFFIC CONTROL IN OR ADJACENT TO NCDOT
RIGHT-OF-WAY. TRAFFIC CONTROL SHALL BE MAINTAINED AT ALL TIMES WITH PROPER SIGNAGE, SIGNALS,
LIGHTING, FLAGMEN. ALL SIGNS, PAVEMENT MARKINGS AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM
TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION.
7.COPIES OF ALL PERMITS AND APPROVED PLANS MUST BE KEPT ON SITE IN A PERMIT BOX THAT IS
CONSPICUOUSLY LOCATED AND EASILY ACCESSIBLE DURING CONSTRUCTION. THIS INCLUDES APPROVED
CONSTRUCTION PLANS, APPROVED EROSION CONTROL PLANS, ENCROACHMENT AGREEMENTS, DRIVEWAY
PERMITS, WATER/SEWER PERMITS, ETC.
8.LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE AND MUST BE FIELD VERIFIED. CONTACT THE NC ONE
CALL CENTER AT LEAST 48 HOURS PRIOR TO DIGGING @ 1.800.632.4949. UNDERGROUND LINES SHOWN HEREON
ARE APPROXIMATE OR AS REPORTED BY VARIOUS RESPONSIBLE PARTIES. THE SURVEYOR DOES NOT
GUARANTEE THAT ANY UNDERGROUND STRUCTURES SUCH AS UTILITIES, TANKS AND PIPES ARE LOCATED
HEREON.
9.THE CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OR FIRMS HAVING FACILITIES
ON OR ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING OR
CONNECTING TO SAID FACILITIES.
10.THE CONTRACTOR IS RESPONSIBLE FOR REPAIR OF ANY COUNTY OR NCDOT DAMAGED PROPERTY. THE
CONTRACTOR SHALL REPAIR THE DAMAGED PROPERTY TO THE LATEST STANDARDS AND SPECIFICATIONS OF THE
AGENCY HOLDING JURISDICTION AT NO COST TO THE OWNER.
11.ANY DAMAGE DONE TO PRIVATE PROPERTY OWNERS SIGNS, MAILBOX, DRIVEWAY CULVERTS, OR OTHER
PROPERTY SHALL BE RESTORED TO ORIGINAL CONDITION.
12.CONTRACTOR IS RESPONSIBLE FOR FENCING AND SECURITY OF HIS LAYDOWN AND STORAGE AREA.
13.CONTRACTOR SHALL KEEP ALL ROADS FREE OF DIRT AND DEBRIS AT ALL TIMES.
14.CONTRACTOR SHALL PROTECT EXISTING PAVEMENTS AND UTILITIES FROM HEAVY EARTH MOVING EQUIPMENT.
PROVIDE TRAFFIC CONTROL AND ADEQUATE PROTECTION METHODS AT ALL EQUIPMENT CROSSINGS.
15.ALL EXCAVATION IS UNCLASSIFIED AND SHALL INCLUDE ALL MATERIALS ENCOUNTERED.
16.ALL STRUCTURAL FILL MATERIAL SHALL BE FREE OF ALL STICKS, ROCKS, AND CLUMPS OF MUD. ALL ROCKS
GREATER THAN 3" DURING EXCAVATION SHALL BE REMOVED.
17.UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE
DISPOSED OF OFF-SITE BY THE CONTRACTOR IN AN APPROVED, LEGAL DISPOSAL SITE.
18.CONCRETE SIDEWALKS THAT ARE TO BE REMOVED SHALL BE CUT BACK TO NEAREST EXPANSION OR CONTROL
JOINT AND REPLACED WITH 4-INCH CONCRETE SIDEWALK FINISHED TO MATCH EXISTING SIDEWALKS.
19.CONTRACTOR TO COORDINATE WITH HARNETT COUNTY FOR TEMPORARY WATER NEEDED DURING
CONSTRUCTION. IF PERMITTED TO CONNECT TO EXISTING FIRE HYDRANT, A REDUCED PRESSURE ZONE (RPZ)
BACKFLOW PREVENTER WILL BE REQUIRED.
20.THE TRANSITION OF PROPOSED ROADWAY TO EXISTING ROADWAY SHALL BE DONE WITH A MINIMUM 8-FT
TRANSITION WHERE THE EXISTING PAVEMENT IS MILLED TO A MINIMUM DEPTH OF 1-1/2" AND OVERLAID.
21.ALL PAVEMENT SAW CUTS SHALL BE NEAT, STRAIGHT AND FULL DEPTH.
22.ALL RIP-RAP IS TO BE INSTALLED WITH NON-WOVEN FILTER FABRIC BENEATH (MIRAFI 140 N OR APPROVED EQUAL).
23.ALL EXCESS TOPSOIL AND UNCLASSIFIED EXCAVATION IS TO BE HAULED OFF-SITE, UNLESS OTHERWISE DIRECTED
BY THE OWNER TO AN APPROVED NCDENR LOCATION.
24.ALL SITE CONSTRUCTION MUST BE INSPECTED BY THE GEOTECHNICAL ENGINEER AT THE FOLLOWING STAGES:
A.COMPLETION OF GRADING SUBGRADE PRIOR TO PLACING STONE BASE.
B. COMPLETION OF STONE PLACEMENT PRIOR TO PAVING.
C.FINAL INSPECTION WHEN ALL WORK IS COMPLETE.
25.PRIOR TO PLACING CABC STONE BASE, THE CONTRACTOR SHOULD NOTIFY THE GEOTECHNICAL ENGINEER TO
INSPECT THE PROOF ROLL OF THE SUBGRADE. ANY STONE PLACED WITHOUT PRIOR APPROVAL WILL BE THE
SOLE RESPONSIBILITY OF THE CONTRACTOR AND SUBJECT TO RE-CONSTRUCTION IF SUBGRADE DOES NOT MEET
TOWN AND NCDOT STANDARDS & SPECIFICATION
26.ALL UTILITY SERVICES, (POWER, TELEPHONE, CABLE, ETC.) ARE PROPOSED TO BE UNDERGROUND. DO NOT SEED
OR MULCH DISTURBED AREAS UNTIL ALL UNDERGROUND UTILITIES HAVE BEEN INSTALLED. THE CONTRACTOR
SHALL COORDINATE WITH THE PRIVATE UTILITY SERVICE COMPANIES FOR ANY REQUIRED CONDUITS OR POINT OF
CONTACT CONDITIONS.
27.ALL PUBLIC UTILITIES THAT REQUIRE AN ENGINEERING CERTIFICATION MUST BE INSPECTED BY A PROFESSIONAL
ENGINEER ON A PERIODIC BASIS. THE CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER WHEN INSTALLING
UTILITIES FOR PERIODIC INSPECTIONS. THE CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER AT THE TIME
OF PRESSURE TESTING AND WATER LINE DISINFECTION. THE CONTRACTOR SHALL SUPPLY THE PROJECT
ENGINEER PRESSURE TEST RESULTS.
28.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD
CONDITIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATION
OF ALL EXISTING UTILITIES BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF
TRENCHING. IF THE CLEARANCES ARE LESS THAN SPECIFIED ON THE PLANS OR 12 INCHES, WHICH EVER IS LESS,
CONTACT THE PROJECT ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION.
29.THE CONTRACTOR SHALL INCLUDE IN HIS CONTRACT PRICE THE REMOVAL AND DISPOSAL OF ANY EXCESS
TOPSOIL HE DETERMINES IS NOT REQUIRED TO PERFORM THE FINAL GRADING AND LANDSCAPING OPERATION.
30.THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE DAILY RECORD KEEPING OF THE AS-BUILT
CONDITION OF ALL OF THE UNDERGROUND UTILITIES, CONSTRUCTION STAKEOUT ASSOCIATED WITH THE
PROJECT. PREPARATION OF THE NECESSARY/REQUIRED AS-BUILT PLANS TO BE SUBMITTED TO HARNETT
COUNTY AND/OR ALL OTHER INFORMATION REQUIRED IN CONNECTION WITH RELEASE OF BONDS.
31.THE CONTRACTOR SHALL INCLUDE IN THE PRICE, ANY AND ALL COSTS ASSOCIATED WITH PROVIDING A
PROFESSIONAL ENGINEER ON SITE IF REQUIRED, DURING THE CONSTRUCTION OF THE STORMWATER
MANAGEMENT FACILITIES, UNDERGROUND UTILITIES, ETC. AS REQUIRED FOR AS-BUILT CERTIFICATION.
32.THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY
SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA,
FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THE
DRAWINGS. NCDOT, HARNETT COUNTY & CURRY ENGINEERING ACCEPT NO RESPONSIBILITY FOR THE DESIGN TO
INSTALL SAID ITEMS.
33.TESTING BY CONTRACTOR: CONTRACTOR SHALL EMPLOY AT HIS EXPENSE AN OUTSIDE INDEPENDENT SOIL
TESTING SERVICE (APPROVED BY THE OWNER) TO PERFORM SOIL TESTING AND INSPECTION SERVICE FOR
QUALITY CONTROL TESTING DURING EARTHWORK OPERATIONS. COPIES OF RESULTS OF TESTS SHALL BE
SUBMITTED BY THE TESTING SERVICE DIRECTLY TO THE CONTRACTOR, THE OWNER, AND THE APPLICABLE
APPROVING AGENCY. --THE TESTING SERVICE WILL CLASSIFY PROPOSED ON-SITE AND BORROW SOILS TO VERIFY
THAT SOILS COMPLY WITH SPECIFIED REQUIREMENTS AND TO PERFORM REQUIRED FIELD AND LABORATORY
TESTING. (MINIMUM REQUIRED SOIL BEARING CAPACITY IS NOTED ON THE STRUCTURAL DRAWINGS). --IN PAVED
AND BUILDING SLAB AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD DENSITY TEST FOR EACH
2000 SQUARE FEET OF FILL IN EACH COMPACTED FILL LAYER. IF A TEST SHOULD FAIL TO MEET REQUIRED
DENSITY, THE CONTRACTOR SHALL RE-COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM
ADDITIONAL TESTS AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE
REQUIRED COMPACTION. --IN FOUNDATION WALL AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD
DENSITY TEST FOR EACH 100 FEET OR LESS OF WALL LENGTH OF FILL IN EACH COMPACTED FILL LAYER, WITH NO
LESS THAN TWO TESTS ALONG A WALL FACE. IF A TEST SHOULD FAIL TO MEET REQUIRED DENSITY, THE
CONTRACTOR SHALL RE-COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM ADDITIONAL TESTS
AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE REQUIRED COMPACTION.
34.COMPACTION: COMPACT EACH LAYER OF BACKFILL AND FILL SOIL MATERIALS AND THE TOP 12" OF SUBGRADE IN
CUT AREAS TO 100% OF MAXIMUM DENSITY IN ACCORDANCE WITH AASHTO T99 FOR STRUCTURES, SLABS, AND
PAVEMENTS AND 95% OF MAXIMUM DENSITY FOR EMBANKMENTS OR UNPAVED AREAS. MAX LIFT THICKNESS FOR
FILL AREAS IS 8 INCHES.
35.DISTURBED AREA IS IN EXCESS OF 1 ACRE AND FORMAL SEDIMENTATION & EROSION CONTROL PLAN APPROVAL IS
REQUIRED AS A CONDITION OF CONSTRUCTION PLAN APPROVAL. A COPY OF THE APPROVED EROSION CONTROL
PLAN MUST BE KEPT ON SITE AT ALL TIMES. THE APPROVED SEDIMENTATION & EROSION CONTROL PLAN SHOULD
BE REGARDED AS MINIMUM REQUIREMENTS; ADDITIONAL MEASURES SHALL BE PUT IN PLACE AS NEEDED TO
ENSURE THAT NO SEDIMENT IS RELEASED FROM THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR PICKING UP
AND PAYING FOR GRADING PERMIT ISSUED BY NCDENR DIVISION OF ENERGY, MINERALS AND LAND QUALITY.
36.DESIGN/FIELD CONDITIONS QUITE EASILY MAY VARY FROM THAT REPRESENTED IN THE INITIAL SOILS REPORT
AND/OR TOPOGRAPHICAL REPORT. ISOLATED AREAS MAY SHOW UP WEAK AND ADVERSE SOILS OR
GROUNDWATER CONDITIONS MAY BE DISCOVERED THAT WERE NOT REVEALED DURING THE INITIAL SOILS
INVESTIGATION. THEREFORE, THE OWNER/CLIENT IS TO BE AWARE THAT CURRY ENGINEERING GROUP, PLLC WILL
NOT AND CANNOT BE HELD RESPONSIBLE FOR ANY FAILURES TO EITHER A STREET OR PARKING LOT PAVEMENT
DESIGN UNLESS WE CAN BE FULLY AND TOTALLY INVOLVED IN THE CONSTRUCTION PROCESS WHICH MAY
INCLUDE, BUT MAY NOT NECESSARILY BE LIMITED TO, TESTING SUBGRADE AND BASE DENSITY, ENGAGING THE
GEOTECHNICAL ENGINEER FOR THE EVALUATION OF THE SUBGRADE AND FOR THE OBSERVATION OF PROOF
ROLLING SUBGRADE AND BASE AT VARIOUS STEPS OF CONSTRUCTION, OPPORTUNITY FOR THE DESIGN
ENGINEER TO CALL IN A GEOTECHNICAL ENGINEER FOR CONSULTATION AND ADVICE, ETC. - STEPS WHICH TAKEN
ALTOGETHER WITH THE INITIAL DESIGN SHOWN ON THE PLANS, CONSTITUTE THE COMPLETE DESIGN OF THE
ROAD, STREET OF PARKING AREA (PRIVATE OR PUBLIC). THE DESIGN ENGINEER MUST BE GIVEN THE FULL
LATITUDE AND OPPORTUNITY TO COMPLETE THE DESIGN BY FULLY PARTICIPATING IN THE CONSTRUCTION
PROCESS. PLAN DESIGN IS A SMALL PORTION OF THE DESIGN AND CANNOT BE SEPARATED FROM THE
CONSTRUCTION PROCESS IF THE OWNER'S/CLIENT'S DESIRE IS TO HAVE THE DESIGN ENGINEER STAND BEHIND
THE COMPLETED DESIGNED PROJECT.
GENERAL CONSTRUCTION NOTES:
P PROPERTY LINE
L
L
CENTERLINE
DIAMETER OR ROUND
C
AND &
-- C --
-- A --
-- B --
-- D --
-- E --
-- F --
-- G --
-- H --
-- I --
-- L --
** ALL SYMBOLS & ABBREVIATIONS SHOWN ON THIS SHEET
MAY OR MAY NOT BE USED IN THIS DRAWING PACKAGE **
IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION
GENERAL ABBREVIATIONS:
ABC AGGREGATE BASE
ASPH ASPHALT
AVE AVENUE
BLVD BOULEVARD
BLDG BUILDING
BOC BACK OF CURB
BW BOTTOM OF WALL
CB CATCH BASIN
CI CURB INLET
CIP CAST IRON PIPE
CLS CLASS
CJ CONTROL JOINT
CO CLEANOUT
CONC CONCRETE
DI DROP INLET
DIA DIAMETER
DIP DUCTILE IRON PIPE
DOM DOMESTIC
DR DRIVE
(XX) EXISTING ELEVATION
E EAST, EASTING
EL ELEVATION
EJ EXPANSION JOINT
EOP EDGE OF PAVEMENT
EX EXISTING
EVAP EVAPORATIVE
FDC FIRE DEPARTMENT
CONNECTION
FES FLARED END SECTION
FFE FINISHED FLOOR ELEVATION
FG FINISHED GRADE
FHA FIRE HYDRANT ASSEMBLY
FL FLOW LINE
FT FOOT OR FEET
G GAS
GALV GALVANIZED
GB GRADE BREAK
GE GENERAL ELECTRIC
GR GRADE
HDPE HIGH DENSITY POLYETHYLENE
HORIZ HORIZONTAL
HOV HIGH OCCUPANCY VEHICLE
HP HIGH POINT
IAW IN ACCORDANCE WITH
I.H.INTERSTATE HIGHWAY
INV INVERT
LEN LENGTH
LEV LOW EMISSION VEHICLE
LF LINEAR FEET
LP LOW POINT
www.ncocc.org
BEFORE YOU DIG,
CALL
NORTH CAROLINA
ONE CALL CENTER
-- M --
-- N --
-- O --
-- P --
-- R --
-- S --
-- T --
-- U --
-- V --
-- W --
-- Y --
MAX MAXIMUM
MH MANHOLE
MIN MINIMUM
N NORTH, NORTHING
NCDENR NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT & NATURAL RESOURCES
NCDOT NORTH CAROLINA DEPARTMENT OF
TRANSPORTATION
NTS NOT TO SCALE
OH OVERHEAD
OCB OFF-SET CATCH BASIN
PCC PORTLAND CEMENT CONCRETE
PE POLYETHYLENE
PKWY PARKWAY
POC POINT OF CONNECTION
PVC POLYVINYL CHLORIDE
R RADIUS
RCP REINFORCED CONCRETE PIPE
R.O.W. RIGHT OF WAY
RPDA REDUCED PRESSURE
DETECTOR ASSEMBLY
RPZ REDUCED PRESSURE ZONE
S SOUTH
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SDE SIGHT DISTANCE EASEMENT
SSMH SANITARY SEWER MANHOLE
SS SANITARY SEWER
STA STATION
STD STANDARD
ST.STL STAINLESS STEEL
SWPPP STORMWATER POLLUTION
PREVENTION PLAN
TB TOP OF BARRIER
TC/TOC TOP OF CURB
TD TEMPORARY DIVERSION
TH TEST HEADER
TOP TOP OF PIPE
TP TOP OF PAD
TYP TYPICAL
TW TOP OF WALL
UG UNDERGROUND
VEG VEGETATED
VERT VERTICAL
W WEST
W/ WITH
W/O WITHOUT
YI YARD INLET
IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION
C0.1N.T.S.CIVIL NOTESNOT FOR CONSTRUCTION
WTLD
WTLD
WTLD
WTLD
WTLD
WTLDWTLDWTLDWTLD
WTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWT
L
D
W
T
L
D
W
T
L
D
WT
L
D
W
T
L
D
WTLDmain st.60' R/Wmai
n st.
6
0
'
R
/W
boykin rd.
VARIABLE WIDTH R/W
LINDA NEWTON YOUNG
MICHAEL L YOUNG
PIN: 0680-08-2617
D.B.3003, PG.674
ZONING: RA-30
BRYAN K BLINSON
BETH M BLINSON
PIN: 0670-98-9869
D.B.1801, PG.326
ZONING: RA-30
BRYAN K BLINSON
BETH M BLINSON
PIN: 0670-99-6018
D.B.1801, PG.326
ZONING: RA-30
HERBERT L SANDER
BETTIE B SANDER
PIN: 0680-09-2725
D.B.867, PG.240
ZONING: RA-30
AREA: 56.92 AC
CHARLES H ENNIS
BARBARA O ENNIS
PIN: 0670-89-9822
D.B.2745, PG.8
ZONING: RA-30
CHARLES H ENNIS
BARBARA O ENNIS
PIN: 0671-90-4592
D.B.2141, PG.54
ZONING: RA-30
KATHY M CUNHA
FABIANO CUNHA
PIN: 0681-00-7185
D.B.3979, PG.889
ZONING: RA-30
WxWxWxWxWxWxWxWxWxWxWxWxWxWxWxWxPP
PP
PPOHEOHEOHEOHEOHE OHEOHEOHEOHE
OHE
PP
PP
OHEOHEOHEOHEOHEOHEOHEPP
230
240
250
240
222
224
226
228
232
234
236
238
242
244
2
4
6
24
8
252
254
234
236
238
242
244
246 mitchell rd.EXISTING IRON PIPE (CONTROL POINT)
CONCRETE MONUMENT SET
EXISTING CONCRETE MONUMENT(CONTROL POINT)
IRON STAKE SET (UNLESS OTHERWISE NOTED)
40 D NAIL
EIS
COMPUTED POINT ONLY
PROPERTY BOUNDARY
EASEMENT
500 YR FLOOD PLAIN
100 YR FLOOD PLAIN
WTLD WETLANDS BOUNDARY
RIPARIAN BUFFER
OHE OVERHEAD POWER
FLOODWAY
FLD
FW
EXISTING IRON STAKE
FLOOD HAZARD SOILS BOUNDARY
MINOR CONTOUR
MAJOR CONTOUR
Wx EXISTING WATER
SS x EXISTING SANITARY SEWER
350
SANITARY SEWER MANHOLE
Cx
u U/G TELECOMMUNICATIONS
FO U/G FIBER DATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C1.0 EXISTING CONDITIONS PLAN.DWGPLOTTED: 10/20/2021 3:14 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-009GENERAL NOTES:
1.THIS PLAN IS NOT INTENDED FOR PLATTING OR RECORDATION.
2.THE INTENT OF THIS PLAN IS TO ILLUSTRATE THE EXISTING FEATURES, STRUCTURES AND TOPOGRAPHY OF
THE PROPERTY. THE INFORMATION SHOWN ON THIS PLAN WAS PROVIDED AND DEVELOPED BY OTHERS.
CURRY ENGINEERING DOES NOT GUARANTEE THE ACCURACY OF THE INFORMATION, THUS IT HAS NOT BEEN
SEALED. THE BOUNDARY & ENVIRONMENTAL INFORMATION SHOWN REPRESENTS A SERIES OF FIELD
SURVEYS.
3.TOPOGRAPHY SHOWN ON THIS PLAN IS PER NC ONE MAP GIS.
4.EXISTING WATER LINES SHOWN ON THIS PLAN FROM HARNETT COUNTY GIS.
5.THE ENGINEER UNDERSTANDS THE PRELIMINARY INFORMATION PROVIDED TO MEET THE FOLLOWING
CRITERIA:
·THE PROPERTY SHOWN HEREON IS SUBJECT TO ALL EASEMENTS OF RECORD AFFECTING SAME.
PROPERTY BOUNDARY SHOWN BASED PER MAPS AND DEEDS OF RECORD ONLY.
·NO TITLE SEARCH HAS BEEN PERFORMED BY THIS FIRM DURING THE COURSE OF THIS SURVEY.
·THIS INFORMATION DOES NOT CERTIFY TO THE EXISTENCE OR NON-EXISTENCE OF ANY UNDER
GROUND UTILITIES THAT MAY OR MAY NOT BE PRESENT ON THIS SITE.
6.FLOOD HAZARD SOILS ARE NOT ANTICIPATED ON THIS PROPERTY PER HARNETT COUNTY GIS.
N
SCALE IN FEETSCALE IN FEET
HORIZONTAL
80'160'040'80'
SCALE: 1 IN = 80 FT
C1.01" = 80'EXISTING CONDITIONS PLANNOT FOR CONSTRUCTION
LEGEND:
EXISTING PROPERTY LINE
(SHOWN PER GIS)
JURISDICTIONAL
WETLANDS
JURISDICTIONAL
WETLANDS
TREELI
N
E
TREELINE
CEMETERY
EXISTING OVERHEAD POWER
EXISTING 4" WATERLINE
(SHOWN PER GIS)
PROPOSED PROJECT AREA = 38.69 AC
EXISTING OVERHEAD POWER
WTLD
WTLD
WTLD
WTLD
WTLD
WTLDWTLDWTLDWTLD
WTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDW
T
L
D
W
T
L
D
W
T
L
D
WT
LD
W
T
L
D
WTLDmain st.60' R/Wmai
n st.
6
0
'
R
/W
boykin rd.
VARIABLE WIDTH R/W
LINDA NEWTON YOUNG
MICHAEL L YOUNG
PIN: 0680-08-2617
D.B.3003, PG.674
ZONING: RA-30
BRYAN K BLINSON
BETH M BLINSON
PIN: 0670-98-9869
D.B.1801, PG.326
ZONING: RA-30
BRYAN K BLINSON
BETH M BLINSON
PIN: 0670-99-6018
D.B.1801, PG.326
ZONING: RA-30
CHARLES H ENNIS
BARBARA O ENNIS
PIN: 0670-89-9822
D.B.2745, PG.8
ZONING: RA-30
CHARLES H ENNIS
BARBARA O ENNIS
PIN: 0671-90-4592
D.B.2141, PG.54
ZONING: RA-30
KATHY M CUNHA
FABIANO CUNHA
PIN: 0681-00-7185
D.B.3979, PG.889
ZONING: RA-30
WxWxWxWxWxWxWxWxWxWxWxWxWxWxWxWxPP
PP
PP
PP
PPmitchell rd.OPEN SPACE
1.88 AC
EXISTING CEMETERY / OPEN SPACE
0.69 AC
OPEN SPACE
4.04 AC
OPEN SPACE
5.61 AC
CBU
19
18
17
16
15
14
13
55
47 54
46
53
45
52
44
51
43
50
56
49
48
30
29
28
34
27
33
32
31
20
12
6
5
4
11
3
10
2
9
1
8
7
24
23
22
21
26
25
38
3940
42
37
36
35
CBU
41
EM
E
RI
T
U
S
W
A
Y
SCHOLARS LANE
CHA
N
C
E
L
L
O
R
D
RI
V
ECHARTER DR
IVE
GRADUATE ROAD
TOWNES AT NORTH MAIN
SHOWN FOR REFERENCE ONLY
STORMWATER
CONTROL
MEASURE (SCM)
PROPOSED PUMP STATION
CLUSTER
MAILBOX
UNIT
75' PRIME VIEWS &
VISTAS BUFFER
50' PRIME VIEWS &
VISTAS BUFFER
NO BUFFER REQUIREDNOT PART OF SUBDIVISION
(2.80 AC)
PROJECT AREA
STORMWATER
CONTROL
MEASURE (SCM)DATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C2.0 MASTER DEVELOPMENT PLAN.DWGPLOTTED: 10/20/2021 3:14 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-009C2.01" = 80'MASTER DEVELOPMENT PLANNOT FOR CONSTRUCTION
N
SCALE IN FEETSCALE IN FEET
HORIZONTAL
80'160'040'80'
SCALE: 1 IN = 80 FT
SITE INFORMATION
CONVENTIONAL SUBDIVISION
ZONING:
COUNTY:
LOCATION:
PARENT PIN:
PROPERTY BOUNDARY:
HARNETT
LAND CLASS:RURAL
56.92 AC
LOT ACREAGE:
SIDE YARD:
FRONT YARD:25'
10'
REAR YARD:20'
MINIMUM BUILDING SETBACKS:
SIDE YARD, CORNER LOT:20'
IMPERVIOUS AREAS:
ROADWAYS:2.55 AC
SIDEWALKS:
TOTAL ON-SITE IMPERVIOUS AREA:
TOTAL ON-SITE IMPERVIOUS PERCENT:23.8%
OPEN SPACE / AMENITY:
38.69 AC
REQUIRED OPEN SPACE (30%):11.61 AC
OPEN SPACE PROVIDED:12.23 AC (31.61%)
PROJECT AREA:
RA-30
MAIN STREET
BUIES CREEK, NC 27546
0680-09-2725
0.88 AC
9.22 AC
TOTAL NUMBER PROPOSED UNITS:56
LOTS (EST. 4,500 SF/ LOT):5.79 AC
PROJECT AREA:38.69 AC
UTILITY DEMANDS
SEWAGE USAGE:
WATER USAGE:
300 GPD/UNIT
(56 UNITS x 300 GPD) = 16,800 GPD
400 GPD/UNIT
(56 UNITS x 400 GPD) = 22,400 GPD
MINIMUM PROPOSED LOT SIZE:12,600 SF
MAXIMUM PROPOSED LOT SIZE:25,678 SF
AVERAGE PROPOSED LOT SIZE:15,061 SF
MINIMUM LOT WIDTH:70'
MINIMUM ALLOWABLE LOT SIZE:12,500 SF
(NOT TO SCALE)
WAX MYRTLE (MYRICA CERIFERA)
24" HIGH @ PLANTING
WILLOW OAK (QUERCUS PHELLOS)
2" CALIPER, 6' HIGH @ PLANTING
STREETYARD BUFFER PLANTING
15'
50' MAX
7'
100'
MIN.
(WITHIN 50' & 75' PRIME VIEWS & VISTAS BUFFER)
2.80 AC (NOT IN SUBDVN.)
54.12 AC (REVISED BNDY.)
WTLD
WTLD WTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDboykin rd.
VARIABLE WIDTH R/W
CHARLES H ENNIS
BARBARA O ENNIS
PIN: 0671-90-4592
D.B.2141, PG.54
ZONING: RA-30 PPPPPP19
18
17
16
15
14
13
47 54
53
52
51
50
49
48
28
27
20
12
6
11
10
9
8
7
24
23
22
21
26
25
LOT
20,116 SQFT.
0.46 AC.
LOT
16,118 SQFT.
0.37 AC.
LOT
17,500 SQFT.
0.40 AC.
LOT
15,758 SQFT.
0.36 AC.
LOT
21,253 SQFT.
0.49 AC.
LOT
16,630 SQFT.
0.38 AC.
LOT
14,211 SQFT.
0.33 AC.
LOT
12,916 SQFT.
0.30 AC.
LOT
12,675 SQFT.
0.29 AC.
LOT
12,765 SQFT.
0.29 AC.
LOT
12,855 SQFT.
0.30 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
14,760 SQFT.
0.34 AC.
LOT
12,609 SQFT.
0.29 AC.
LOT
12,606 SQFT.
0.29 AC.
LOT
12,604 SQFT.
0.29 AC.
LOT
14,518 SQFT.
0.33 AC.
LOT
13,524 SQFT.
0.31 AC.
LOT
13,518 SQFT.
0.31 AC.
LOT
16,184 SQFT.
0.37 AC.
LOT
16,189 SQFT.
0.37 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
16,118 SQFT.
0.37 AC.
LOT
16,200 SQFT.
0.37 AC.
LOT
16,200 SQFT.
0.37 AC.
LOT
16,118 SQFT.
0.37 AC.
LOT
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.10+0011+0012+0013+0014+001
5
+
0
0
1
6
+
0
0
1
7
+
0
0
1
8
+
0
0
1
3
+
0
0
1
4
+
0
0
1
5
+
0
0
1
6
+
0
0
1
7
+
0
0
1
7
+
1
4
10+0011+0012+0013+0014+0014+10
7
0
.
0
0
'
7
0
.
0
0
'180.43'7
0
.
0
0
'181.72'7
0
.
0
0
'183.00'7
0
.
0
1
'
7
0
.
0
0
'184.29'7
0
.
0
1
'
5
5
.
4
4
'16.44
'179.04'7
0
.
0
1
'61.25
'176.37'1
1
6
.
2
9
'
41.17'161.00'174.23'2.
1
2
'41.18'146.
3
3
'42.51'76.88'118.94'46.58'156.42'70.00'70.00'27.49'54.
4
9
'
17.0
8
'
1
5
.
9
4
'30.63'160.50'9
0
.
0
0
'160.50'30.63'
7
0
.
5
0
'180.00'1
0
.
1
4
'135.82
'25.46'180.00'70.00'180.00'70.00'180.00'70.00'180.00'56.09'15.91'15.26'178.96'15.26'18.80'37.60'180.04'73.11'23.81'16.02'
42.58'
44.27'
80.94'70.00'180.07'70.00'70.00'180.11'70.00'70.00'180.14'70.00'43.96'22.89'181.94'83.14'61.55'
205.25'110.47'61.5
5
'
181.8
6'
1
1
0
.
4
8
'
2
2
.
9
4
'
4
3
.
9
1
'180.00'8
3
.
1
6
'
7
0
.
0
0
'180.00'7
0
.
0
0
'90.00'90.00'7
0
.
0
0
'
1
6
0
.
5
0
'30.63'70.50'1
8
0
.
0
0
'90.00'1
8
0
.
0
0
'90.00'1
8
0
.
0
0
'90.00'70.50'30.63'
1
6
0
.
5
0
'90.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'34.06'1
8
.
7
4
'L4L5C3C4L
8L9 OPEN SPACE
1.88 AC
OPEN SPACE
4.04 ACSCHOLARS LANEEM
E
RI
T
U
S
W
A
Y CHARTER DR
IVE
FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMWWWWWWWWWWWWWWWWWWWWWWWW
W
W
W
W
W
W
SS
SS
SS
SS
SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSFM
FM
FM
FM
FM
FM FM F
M
W
W
W W W WMATCHLINE
50' ROW
29' BC/BC
29' BC/BC
50' ROW 29' BC/BC
50' ROW
PROPOSED 12" PVC
WATER MAIN
PROPOSED 4"
FORCE MAIN
PROPOSED 8"
PVC SS MAIN
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
FHA
FHA
FHA
FHA
FHA
FHA
EXISTING 65' ROW
50' PRIME VIEWS &
VISTAS BUFFER
75' PRIME VIEWS &
VISTAS BUFFER
REDUCER WITH 2"
BLOW-OFF ASSEMBLYR1-1
R1-1
R1-1
STREET LIGHT, TYP.
12"x12"x12" TEE W/ TB
(3) 12" GV
12"x12"x12" TEE W/ TB
(3) 12" GV
12"x12"x12" TEE W/ TB
(3) 12" GV
STREET TREE, TYP.
W x
W xPPFM
FM
FM
F
M
F
M
F
M
FM
FM
FM
FMWW
W
W
WMATCHLINE
CBU
ROADWAY CENTER LINE
LOT LINE
RIGHT OF WAY LINE
SETBACK LINE
SCM LIMITS
VALLEY CURB & GUTTER
STANDARD CURB & GUTTER
WCR WHEELCHAIR RAMP
SIGN
STREET LIGHT
SPILL CURB & GUTTER
CLUSTER MAILBOX UNIT
EASEMENT
FENCE
ASPHALT PAVEMENT
CONCRETE SIDEWALK WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
W
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
RISER STRUCTURE
YARD INLET
CATCH BASIN
OPEN THROAT YARD INLET
BACKFLOW PREVENTER DATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C2.1 PARTIAL SITE LAYOUT I.DWGPLOTTED: 10/20/2021 3:15 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-009C2.11" = 40'PARTIAL SITE LAYOUT INOT FOR CONSTRUCTION
N 40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
SCALE:
1
C2.1
GREGORY CIR. & BOYKIN RD.
1" = 40'
WATER CONNECTION ATBOYKIN RD.
G R E G O R Y C IR .MAI
N ST.
WATER CONNECTION TO EXISTING 6" WATER MAIN
PROPOSED 12" PVC WATER MAIN
PROPOSED FORCE MAIN
LEGEND:
GENERAL NOTES:
1.ALL CONSTRUCTION SHALL BE PER HARNETT COUNTY STANDARDS AND SPECIFICATIONS.
2.ALL DIMENSIONS ARE IN FEET AND TO EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.
3.ALL SITE ELEMENTS ARE PERPENDICULAR TO EACH OTHER UNLESS OTHERWISE NOTED.
4.CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, RIGHT-OF-WAYS AND UTILITIES, PUBLIC OR PRIVATE, BEFORE WORKING IN
THESE AREAS.
5.PROTECT ALL PROPERTY MONUMENTS AND PINS. MONUMENTS AND PINS THAT WILL BE DISTURBED DURING CONSTRUCTION SHALL BE
REFERENCED AND REPLACED BY A LICENSED LAND SURVEYOR AT THE COST OF THE CONTRACTOR.
6.CONTRACTOR SHALL MAINTAIN THE SITE IN SUCH A MANNER THAT WORKMEN AND THE PUBLIC WILL BE PROTECTED FROM INJURY AND
ADJOINING PROPERTY PROTECTED FROM DAMAGE
7.CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT LEAST ONCE A
WEEK DURING CONSTRUCTION.
8.CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL DUE TO CONSTRUCTION OPERATIONS. ALL
STREET SURFACES, UTILITY POLES, CULVERTS, DITCHES, CURB AND GUTTER OR OTHER STRUCTURES THAT ARE DISTURBED OR
DAMAGED IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED BY THE CONTRACTOR IN ACCORDANCE
WITH THE APPROPRIATE SPECIFICATIONS.
9.IF DEPARTURES FROM THE DRAWINGS OR SPECIFICATIONS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH
DEPARTURES AND REASONS THEREOF SHALL BE SUBMITTED IN WRITING TO THE FACILITY DESIGNER FOR REVIEW. NO DEPARTURES
FROM THE CONTRACT DOCUMENTS WILL BE ALLOWED WITHOUT APPROVAL BY THE FACILITY DESIGNER.
10.ANY AND ALL QUANTITIES SHOWN OR IMPLIED ON THE PLANS ARE FOR ESTIMATION PURPOSES ONLY.
11.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE
GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.
12.ENTRY SIGNS SHALL BE LOCATED IN A DEDICATED EASEMENT. SIGN MUST REMAIN OUT OF SIGHT TRIANGLES AS SHOWN ON PLANS.
13.ALL ASPHALT EDGES SHALL BE SAW CUT TO PROVIDE A GOOD LONGITUDINAL JOINT. MILL 1.5 FEET @ 1.5 INCHES DEEP MINIMUM TO
PROVIDE A LONGITUDINAL LAP JOIN FOR FINAL SURFACE LAYER. NO MILLING SHALL BE LEFT FOR A PERIOD OF TIME GREATER THAN 48
HOURS BEFORE A STREET IS TO BE PAVED OR RESURFACED.
14.COMMON OPEN SPACE SHALL BE OWNED & MAINTAINED BY HOMEOWNERS ASSOCIATION.
15.ANY SPECIALITY STREET SIGNS INCLUDING POSTS SHALL BE SUBMITTED TO THE HARNETT COUNTY FOR REVIEW AND APPROVAL PRIOR
TO INSTALLATION.
16.ALL PUBLIC AND PRIVATE EASEMENTS SHALL BE RECORDED AS PART OF THE FINAL PLAT OF THE SUBDIVISION. EASEMENTS BASED OF
CENTER OF UTILITY OR PIPE SHALL BE PER AS-BUILT LOCATIONS.
17.AREAS OF PARENT PARCEL THAT ARE NOT SUBDIVIDED TO CREATE SINGLE FAMILY RESIDENTIAL LOTS ARE TO REMAIN AS ONE PARCEL
TO BE OWNED AND MAINTAINED BY THE HOME OWNERS ASSOCIATION OF THE NEIGHBORHOOD.
19.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS SHALL BE TO THE LATEST EDITION OF THE HARNETT
COUNTY DEPT. OF PUBLIC UTILITIES WATER & SEWER ORDINANCE AND THE UTILITY MASTER PLAN.
20.ALL WATER MAINS SHALL BE PUBLIC UTILITIES.
21.CONTRACTOR SHALL CONTACT HARNETT COUNTY UTILITIES PRIOR TO MAKING CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE.
22.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER EXTENSION PERMIT ISSUED BY NCDENR - PUBLIC WATER
SUPPLY.
23.WATER MAINS SHALL BE CLASS 150 C900 PVC I.A.W. AWWA C900 OR THICKNESS CLASS 50 DIP PUSH ON JOINTS I.A.W. AWWA C151 WHERE
NOTED.DUCTILE IRON PIPE WATER MAINS SHALL BE CLASS 350 DIP I.A.W. AWWA C-151 WITH PUSH ON JOINTS I.A.W. AWWA C-111. DIP
SHALL BE CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W. AWWA C-104. ALL DIP BURIED PIPE SHALL HAVE AN
BITUMINOUS EXTERIOR COATING I.A.W. AWWA C-151. MINIMUM BURIAL DEPTH FOR WATER MAIN IS 36 INCHES BELOW FINISHED GRADE.
ALL FITTINGS SHALL BE MECHANICAL JOINTS I.A.W. AWWA C-111.
24.ALL WATER SERVICES TO LOTS SHALL BE 3/4" BLUE POLY TUBING W/TRACER WIRE. MINIMUM BURIAL DEPTH FOR WATER SERVICES IS 24
INCHES.
25.SANITARY SEWER MAINS SHALL BE SDR-35 PVC I.A.W. ASTM D-3034-98 TYPE PSM OR CLASS 250 DIP PUSH ON JOINTS I.A.W. AWWA C-150
AND C-151 WHEN NOTED. DIP SHALL BE LINED WITH PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL.
26.ALL SANITARY SEWER SERVICES TO LOTS SHALL BE 4" SCH-40 PVC.
27.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY UTILITY MUST BE ADJUSTED TO MEET SEPARATION
REQUIREMENTS.
28.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH TRACER WIRE PER HARNETT COUNTY STANDARDS.
29.PRIVATE UTILITIES (TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
30.ELECTRICAL TRANSFORMERS SHALL NOT BE LOCATED WITHIN REQUIRED LANDSCAPED BUFFERS.
31.ALL ELECTRICAL THROUGHOUT THE SUBDIVISION SHALL BE UNDERGROUND.
32.ALL UTILITIES, INCLUDING FIRE HYDRANTS, INSTALLED OUTSIDE OF THE PROPOSED ROW MUST BE IN A PUBLIC UTILITY EASEMENT.
WTLDWTLDmai
n st.
6
0
'
R
/W
15
14
13
55
47 54
46
53
45
52
44
51
43
50
56
49
48
30
29
33
32
31
6
5
4
3
2
9
1
8
7
LOT
16,118 SQFT.
0.37 AC.
LOT
17,500 SQFT.
0.40 AC.
LOT
15,758 SQFT.
0.36 AC.
LOT
12,916 SQFT.
0.30 AC.
LOT
12,675 SQFT.
0.29 AC.
LOT
12,616 SQFT.
0.29 AC.
LOT
12,655 SQFT.
0.29 AC.
LOT
12,703 SQFT.
0.29 AC.
LOT
12,750 SQFT.
0.29 AC.
LOT
16,381 SQFT.
0.38 AC.
LOT
12,765 SQFT.
0.29 AC.
LOT
12,855 SQFT.
0.30 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
16,118 SQFT.
0.37 AC.
LOT
16,142 SQFT.
0.37 AC.
LOT
16,200 SQFT.
0.37 AC.
LOT
16,200 SQFT.
0.37 AC.
LOT
16,118 SQFT.
0.37 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
16,118 SQFT.
0.37 AC.
LOT 10+00
11+0012+00
13+0014+0015+0016+00
17+00
17+05
1
7
+
0
0
1
8
+
0
0
1
9
+
0
0
2
0
+
0
0
2
1
+
0
0
2
2
+
0
0
23+001
0
+
0
0
1
1
+
0
0
1
2
+
0
0
1
3
+
0
0
1
4
+
0
0
1
5
+
0
0
1
6
+
0
0
1
7
+
0
0
1
7
+
1
4
11+0012+00
13+0014+00 14+10
160.00'30.63'
7
0
.
5
0
'182.49'8
9
.
6
2
'3.89'7
0
.
0
0
'181.81'7
0
.
0
0
'
7
0
.
0
0
'181.13'7
0
.
0
0
'
7
0
.
0
0
'180.45'7
0
.
0
0
'
7
0
.
0
0
'180.43'2
3
.
4
4
'
4
6
.
5
7
'
7
0
.
0
0
'181.72'7
0
.
0
1
'
7
0
.
0
0
'183.00'7
0
.
0
1
'
7
0
.
0
0
'184.29'7
0
.
0
1
'
5
5
.
4
4
'16.44
'179.04'61.25
'41.18'46.58'156.42'70.00'70.00'54.
4
9
'
17.0
8
'
1
5
.
9
4
'30.63'160.50'9
0
.
0
0
'160.50'30.63'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'180.00'1
1
.
6
4
'
8.
3
6
'
5
0
.
0
0
'
7
0
.
0
0
'180.00'1
1
.
6
4
'
5
8
.
3
6
'
5
8
.
3
6
'180.70'166.
7
5
'135.81'29.92'
30.30'
3
2
.
8
9
'
3
3
.
2
2
'180.00'9
0
.
0
0
'
7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'90.00'90.00'7
0
.
0
0
'
1
6
0
.
5
0
'30.63'70.50'1
8
0
.
0
0
'90.00'1
8
0
.
0
0
'90.00'1
8
0
.
0
0
'90.00'70.50'30.63'
1
6
0
.
5
0
'90.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'160.50'7
0
.
5
0
'30.63'34.06'1
8
.
7
4
'L1L2L3 C1C2
L
6
C5L
8L9
EXISTING CEMETERY / OPEN SPACE
0.69 AC
EM
E
RI
T
U
S
W
A
Y
CHARTER DR
IVE
SCHOLARS LANE
CHA
N
C
E
L
L
O
R
D
RI
V
E
TOWNES AT NORTH MAIN
SHOWN FOR REFERENCE ONLY
FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMW
W
W
W
W
W
W
W
W
W
W
WWWWWWWWWWWWWWWWWWWWWWWWW
W
W
W
W
W
W
SSSS
SS
SS SS
SS
SS SS
SS
SS SS
SS SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSS
SS SS
SS
SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWW29' BC/BC
50' ROW
29' BC/BC
50' ROW
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
FHA
FHA
29' BC/BC
50' ROW
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
29' BC/BC
50' ROW
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
PROPOSED 4"
FORCE MAIN
FHA
FHA
FHA
FHA
75' PRIME VIEWS &
VISTAS BUFFER
STREET LIGHT, TYP.
R1-1
R1-1
R1-1
R1-1
R1-1
REDUCER WITH 2"
BLOW-OFF ASSEMBLY
12"x12"x12" TEE W/ TB
(3) 12" GV
12"x12"x12" TEE W/ TB
(3) 12" GV
12"x12"x12" TEE W/ TB
(3) 12" GV
12"x12"x12" TEE W/ TB
(3) 12" GV
STREET TREE, TYP.
CBU
ROADWAY CENTER LINE
LOT LINE
RIGHT OF WAY LINE
SETBACK LINE
SCM LIMITS
VALLEY CURB & GUTTER
STANDARD CURB & GUTTER
WCR WHEELCHAIR RAMP
SIGN
STREET LIGHT
SPILL CURB & GUTTER
CLUSTER MAILBOX UNIT
EASEMENT
FENCE
CBU
ROADWAY CENTER LINE
LOT LINE
RIGHT OF WAY LINE
SETBACK LINE
SCM LIMITS
VALLEY CURB & GUTTER
STANDARD CURB & GUTTER
WCR WHEELCHAIR RAMP
SIGN
STREET LIGHT
SPILL CURB & GUTTER
CLUSTER MAILBOX UNIT
EASEMENT
FENCE
ASPHALT PAVEMENT
CONCRETE SIDEWALK WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
W
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
RISER STRUCTURE
YARD INLET
CATCH BASIN
OPEN THROAT YARD INLET
BACKFLOW PREVENTER
LINE TABLE
NAME
L4
L5
L6
L7
ROADWAY
SCHOLARS LANE
SCHOLARS LANE
SCHOLARS LANE
SCHOLARS LANE
LENGTH
65.26'
291.56'
643.37'
261.39'
DIRECTION
S42°20'56"W
S39°02'03"W
S1°04'26"W
S40°13'10"W
BEGIN
STATION
10+00.00
10+82.61
15+26.55
23+27.06
END
STATION
10+65.26
13+74.17
21+69.92
25+88.45
LINE TABLE
NAME
L1
L2
L3
ROADWAY
CHANCELLOR DRIVE
CHANCELLOR DRIVE
CHANCELLOR DRIVE
LENGTH
77.15'
544.35'
12.05'
DIRECTION
N89°28'55"W
N88°55'34"W
N71°44'33"W
BEGIN
STATION
10+00.00
10+80.06
16+93.39
END
STATION
10+77.15
16+24.41
17+05.44
LINE TABLE
NAME
L8
ROADWAY
CHARTER DRIVE
LENGTH
713.82'
DIRECTION
N1°04'26"E
BEGIN
STATION
10+00.00
END
STATION
17+13.82
CURVE TABLE
NAME
C1
C2
ROADWAY
CHANCELLOR DRIVE
CHANCELLOR DRIVE
RADIUS
300.00'
230.00'
ARC
LENGTH
2.91'
68.98'
CHORD
LENGTH
2.91'
68.72'
CHORD
DIRECTION
N89°12'14"W
N80°20'04"W
BEGIN
STATION
10+77.15
16+24.41
END
STATION
10+80.06
16+93.39
CURVE TABLE
NAME
C3
C4
C5
ROADWAY
SCHOLARS LANE
SCHOLARS LANE
SCHOLARS LANE
RADIUS
300.00'
230.00'
230.00'
ARC
LENGTH
17.36'
152.38'
157.14'
CHORD
LENGTH
17.35'
149.61'
154.10'
CHORD
DIRECTION
S40°41'29"W
S20°03'14"W
S20°38'48"W
BEGIN
STATION
10+65.26
13+74.17
21+69.92
END
STATION
10+82.61
15+26.55
23+27.06
CURVE TABLE
NAME
C6
ROADWAY
GRADUATE ROAD
RADIUS
230.00'
ARC
LENGTH
204.14'
CHORD
LENGTH
197.51'
CHORD
DIRECTION
S24°21'12"E
BEGIN
STATION
11+95.91
END
STATION
14+00.05
LINE TABLE
NAME
L10
L11
ROADWAY
GRADUATE ROAD
GRADUATE ROAD
LENGTH
195.91'
983.52'
DIRECTION
S1°04'26"W
S49°46'50"E
BEGIN
STATION
10+00.00
14+00.05
END
STATION
11+95.91
23+83.57
LINE TABLE
NAME
L9
ROADWAY
EMERITUS WAY
LENGTH
410.00'
DIRECTION
S88°55'34"E
BEGIN
STATION
10+00.00
END
STATION
14+10.00 DATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C2.2 PARTIAL SITE LAYOUT II.DWGPLOTTED: 10/20/2021 3:16 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-009C2.21" = 40'PARTIAL SITE LAYOUT IINOT FOR CONSTRUCTION
N
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
LEGEND:
GENERAL NOTES:
1.ALL CONSTRUCTION SHALL BE PER HARNETT COUNTY STANDARDS AND SPECIFICATIONS.
2.ALL DIMENSIONS ARE IN FEET AND TO EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.
3.ALL SITE ELEMENTS ARE PERPENDICULAR TO EACH OTHER UNLESS OTHERWISE NOTED.
4.CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, RIGHT-OF-WAYS AND UTILITIES, PUBLIC OR PRIVATE,
BEFORE WORKING IN THESE AREAS.
5.PROTECT ALL PROPERTY MONUMENTS AND PINS. MONUMENTS AND PINS THAT WILL BE DISTURBED DURING
CONSTRUCTION SHALL BE REFERENCED AND REPLACED BY A LICENSED LAND SURVEYOR AT THE COST OF THE
CONTRACTOR.
6.CONTRACTOR SHALL MAINTAIN THE SITE IN SUCH A MANNER THAT WORKMEN AND THE PUBLIC WILL BE PROTECTED
FROM INJURY AND ADJOINING PROPERTY PROTECTED FROM DAMAGE
7.CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT
LEAST ONCE A WEEK DURING CONSTRUCTION.
8.CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL DUE TO CONSTRUCTION
OPERATIONS. ALL STREET SURFACES, UTILITY POLES, CULVERTS, DITCHES, CURB AND GUTTER OR OTHER STRUCTURES
THAT ARE DISTURBED OR DAMAGED IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR
REPAIRED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROPRIATE SPECIFICATIONS.
9.IF DEPARTURES FROM THE DRAWINGS OR SPECIFICATIONS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF
SUCH DEPARTURES AND REASONS THEREOF SHALL BE SUBMITTED IN WRITING TO THE FACILITY DESIGNER FOR REVIEW.
NO DEPARTURES FROM THE CONTRACT DOCUMENTS WILL BE ALLOWED WITHOUT APPROVAL BY THE FACILITY
DESIGNER.
10.ANY AND ALL QUANTITIES SHOWN OR IMPLIED ON THE PLANS ARE FOR ESTIMATION PURPOSES ONLY.
11.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS
WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.
12.ENTRY SIGNS SHALL BE LOCATED IN A DEDICATED EASEMENT. SIGN MUST REMAIN OUT OF SIGHT TRIANGLES AS SHOWN
ON PLANS.
13.ALL ASPHALT EDGES SHALL BE SAW CUT TO PROVIDE A GOOD LONGITUDINAL JOINT. MILL 1.5 FEET @ 1.5 INCHES DEEP
MINIMUM TO PROVIDE A LONGITUDINAL LAP JOIN FOR FINAL SURFACE LAYER. NO MILLING SHALL BE LEFT FOR A PERIOD
OF TIME GREATER THAN 48 HOURS BEFORE A STREET IS TO BE PAVED OR RESURFACED.
14.COMMON OPEN SPACE SHALL BE OWNED & MAINTAINED BY HOMEOWNERS ASSOCIATION.
15.ANY SPECIALITY STREET SIGNS INCLUDING POSTS SHALL BE SUBMITTED TO THE HARNETT COUNTY FOR REVIEW AND
APPROVAL PRIOR TO INSTALLATION.
16.ALL PUBLIC AND PRIVATE EASEMENTS SHALL BE RECORDED AS PART OF THE FINAL PLAT OF THE SUBDIVISION.
EASEMENTS BASED OF CENTER OF UTILITY OR PIPE SHALL BE PER AS-BUILT LOCATIONS.
17.AREAS OF PARENT PARCEL THAT ARE NOT SUBDIVIDED TO CREATE SINGLE FAMILY RESIDENTIAL LOTS ARE TO REMAIN
AS ONE PARCEL TO BE OWNED AND MAINTAINED BY THE HOME OWNERS ASSOCIATION OF THE NEIGHBORHOOD.
19.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS SHALL BE TO THE LATEST EDITION OF THE
HARNETT COUNTY DEPT. OF PUBLIC UTILITIES WATER & SEWER ORDINANCE AND THE UTILITY MASTER PLAN.
20.ALL WATER MAINS SHALL BE PUBLIC UTILITIES.
21.CONTRACTOR SHALL CONTACT HARNETT COUNTY UTILITIES PRIOR TO MAKING CONNECTION TO ANY COUNTY OWNED
INFRASTRUCTURE.
22.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER EXTENSION PERMIT ISSUED BY NCDENR -
PUBLIC WATER SUPPLY.
23.WATER MAINS SHALL BE CLASS 150 C900 PVC I.A.W. AWWA C900 OR THICKNESS CLASS 50 DIP PUSH ON JOINTS I.A.W.
AWWA C151 WHERE NOTED.DUCTILE IRON PIPE WATER MAINS SHALL BE CLASS 350 DIP I.A.W. AWWA C-151 WITH PUSH
ON JOINTS I.A.W. AWWA C-111. DIP SHALL BE CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W.
AWWA C-104. ALL DIP BURIED PIPE SHALL HAVE AN BITUMINOUS EXTERIOR COATING I.A.W. AWWA C-151. MINIMUM
BURIAL DEPTH FOR WATER MAIN IS 36 INCHES BELOW FINISHED GRADE. ALL FITTINGS SHALL BE MECHANICAL JOINTS
I.A.W. AWWA C-111.
24.ALL WATER SERVICES TO LOTS SHALL BE 3/4" BLUE POLY TUBING W/TRACER WIRE. MINIMUM BURIAL DEPTH FOR WATER
SERVICES IS 24 INCHES.
25.SANITARY SEWER MAINS SHALL BE SDR-35 PVC I.A.W. ASTM D-3034-98 TYPE PSM OR CLASS 250 DIP PUSH ON JOINTS I.A.W.
AWWA C-150 AND C-151 WHEN NOTED. DIP SHALL BE LINED WITH PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL.
26.ALL SANITARY SEWER SERVICES TO LOTS SHALL BE 4" SCH-40 PVC.
27.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY UTILITY MUST BE ADJUSTED TO MEET
SEPARATION REQUIREMENTS.
28.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH TRACER WIRE PER HARNETT COUNTY STANDARDS.
29.PRIVATE UTILITIES (TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS PLAN. THE CONTRACTOR SHALL
COORDINATE THE INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
30.ELECTRICAL TRANSFORMERS SHALL NOT BE LOCATED WITHIN REQUIRED LANDSCAPED BUFFERS.
31.ALL ELECTRICAL THROUGHOUT THE SUBDIVISION SHALL BE UNDERGROUND.
32.ALL UTILITIES, INCLUDING FIRE HYDRANTS, INSTALLED OUTSIDE OF THE PROPOSED ROW MUST BE IN A PUBLIC UTILITY
EASEMENT.
EXISTING CEMETERY / OPEN SPACE
0.69 AC
OPEN SPACE
4.04 AC
WTLD
WTLD
WTLD
WTLD
WTLD
WTLD
WTLD
WTLD
WTLD
WTLD
WTLD
WTLD WTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDCHARLES H ENNIS
BARBARA O ENNIS
PIN: 0670-89-9822
D.B.2745, PG.8
ZONING: RA-30
CHARLES H ENNIS
BARBARA O ENNIS
PIN: 0671-90-4592
D.B.2141, PG.54
ZONING: RA-30 47 54
46
45
44
43
30
29
34
33
32
31
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
16,118 SQFT.
0.37 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
12,600 SQFT.
0.29 AC.
LOT
16,142 SQFT.
0.37 AC.
LOT
12,600 SQFT.
0.29 AC.
38
39
40
42
LOT
13,775 SQFT.
0.32 AC.
LOT
19,776 SQFT.
0.45 AC.
LOT
20,754 SQFT.
0.48 AC.
LOT
20,754 SQFT.
0.48 AC.
37
36
35
LOT
14,350 SQFT.
0.33 AC.
LOT
25,678 SQFT.
0.59 AC.
LOT
14,023 SQFT.
0.32 AC.
SCM #2
1.42 AC 16+00
17+00
17+05
1
8
+
0
0
1
9
+
0
0
2
0
+
0
0
2
1
+
0
0
2
2
+
0
0
23+0024+0025+0025+8810
+
0
0
1
1
+
0
0
12
+
0
0
13+0
0
14+00 15+00 16+00
CBU
7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'180.00'1
1
.
6
4
'
8.
3
6
'
5
0
.
0
0
'
7
0
.
0
0
'180.00'1
1
.
6
4
'
5
8
.
3
6
'160.50'30.63'70.50'180.00'90.00'
57.22'12.79'220.31'80.
9
7
'
4
7
.
5
5
'205.00'2
7
.
3
0
'
169.
1
6
'
7
0
.
0
0
'205.00'5
8
.
3
6
'35.40'180.70'2
4
.
9
7
'17.08
'
44.
6
5
'180.00'166.
7
5
'
41.18'
1
8
0
.
0
0
'
189.42'41.18'180.00'136.12'41.18
'180.00'189.42
'135.81'29.92'
30.30'
3
2
.
8
9
'
3
3
.
2
2
'180.00'9
0
.
0
0
'
7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'180.00'7
0
.
0
0
'
7
0
.
0
0
'90.00'1
6
0
.
5
0
'180.00'180.00'PUMP
STATION
0.19 AC
L3
C2
L
6
L7C5L
1
0
C6
41
LOT
20,753 SQFT.
0.48 AC.
SCM #1
0.98 AC SCHOLARS LANE
CH
A
N
C
E
L
L
O
R
D
RI
V
E
GRADUATE ROAD
TOWNES AT NORTH MAIN
SHOWN FOR REFERENCE ONLY
FM
FM FM FM FM FM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMW
W
WWWWWWWWWWWWWWWWWW
W
W
W W W W
SS
SS
SS SS SS SS SS SSSSSSSSSSSSSSSSSS
SS SS
SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSEEEEFMFMSSESS
29' BC/BC
50' ROW
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
PROPOSED 4"
FORCE MAIN
PROPOSED 12" PVC
WATER MAIN
PROPOSED 8"
PVC SS MAIN
PROPOSED 4" FORCE MAIN
PROPOSED PUMP
STATION
24'
9'
29' BC/BC
50' ROW
R1-1
R1-1
R1-1 FHA
FHA
FHA
FHA
STREET LIGHT, TYP.
18'
END OF ROAD
MARKERS
12"x12"x12"
TEE W/ TB
(3) 12" GV
REDUCER WITH 2"
BLOW-OFF ASSEMBLY
SS CAP/PLUG
12"x12"x12"
TEE W/ TB
(3) 12" GV
STREET TREE, TYP.
CBU
ROADWAY CENTER LINE
LOT LINE
RIGHT OF WAY LINE
SETBACK LINE
SCM LIMITS
VALLEY CURB & GUTTER
STANDARD CURB & GUTTER
WCR WHEELCHAIR RAMP
SIGN
STREET LIGHT
SPILL CURB & GUTTER
CLUSTER MAILBOX UNIT
EASEMENT
FENCE
CBU
ROADWAY CENTER LINE
LOT LINE
RIGHT OF WAY LINE
SETBACK LINE
SCM LIMITS
VALLEY CURB & GUTTER
STANDARD CURB & GUTTER
WCR WHEELCHAIR RAMP
SIGN
STREET LIGHT
SPILL CURB & GUTTER
CLUSTER MAILBOX UNIT
EASEMENT
FENCE
ASPHALT PAVEMENT
CONCRETE SIDEWALK WATER LINE
SANITARY SEWER LINE
STORM DRAIN LINE
W
SS
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEE
THRUST (REACTION) BLOCKING
BLOW OFF VALVE
WATER METER / SERVICE
SANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
RISER STRUCTURE
YARD INLET
CATCH BASIN
OPEN THROAT YARD INLET
BACKFLOW PREVENTER DATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C2.3 PARTIAL SITE LAYOUT III.DWGPLOTTED: 10/20/2021 3:17 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-009C2.31" = 40'PARTIAL SITE LAYOUT IIINOT FOR CONSTRUCTION
N
40'80'
SCALE IN FEET
20'40'
SCALE: 1 IN = 40 FT
SCALE IN FEET
HORIZONTAL
0
LEGEND:
GENERAL NOTES:
1.ALL CONSTRUCTION SHALL BE PER HARNETT COUNTY STANDARDS AND SPECIFICATIONS.
2.ALL DIMENSIONS ARE IN FEET AND TO EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.
3.ALL SITE ELEMENTS ARE PERPENDICULAR TO EACH OTHER UNLESS OTHERWISE NOTED.
4.CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, RIGHT-OF-WAYS AND UTILITIES, PUBLIC OR PRIVATE, BEFORE WORKING IN THESE
AREAS.
5.PROTECT ALL PROPERTY MONUMENTS AND PINS. MONUMENTS AND PINS THAT WILL BE DISTURBED DURING CONSTRUCTION SHALL BE
REFERENCED AND REPLACED BY A LICENSED LAND SURVEYOR AT THE COST OF THE CONTRACTOR.
6.CONTRACTOR SHALL MAINTAIN THE SITE IN SUCH A MANNER THAT WORKMEN AND THE PUBLIC WILL BE PROTECTED FROM INJURY AND
ADJOINING PROPERTY PROTECTED FROM DAMAGE
7.CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT LEAST ONCE A WEEK DURING
CONSTRUCTION.
8.CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL DUE TO CONSTRUCTION OPERATIONS. ALL STREET
SURFACES, UTILITY POLES, CULVERTS, DITCHES, CURB AND GUTTER OR OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY
MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROPRIATE
SPECIFICATIONS.
9.IF DEPARTURES FROM THE DRAWINGS OR SPECIFICATIONS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES
AND REASONS THEREOF SHALL BE SUBMITTED IN WRITING TO THE FACILITY DESIGNER FOR REVIEW. NO DEPARTURES FROM THE CONTRACT
DOCUMENTS WILL BE ALLOWED WITHOUT APPROVAL BY THE FACILITY DESIGNER.
10.ANY AND ALL QUANTITIES SHOWN OR IMPLIED ON THE PLANS ARE FOR ESTIMATION PURPOSES ONLY.
11.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING,
PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.
12.ENTRY SIGNS SHALL BE LOCATED IN A DEDICATED EASEMENT. SIGN MUST REMAIN OUT OF SIGHT TRIANGLES AS SHOWN ON PLANS.
13.ALL ASPHALT EDGES SHALL BE SAW CUT TO PROVIDE A GOOD LONGITUDINAL JOINT. MILL 1.5 FEET @ 1.5 INCHES DEEP MINIMUM TO PROVIDE A
LONGITUDINAL LAP JOIN FOR FINAL SURFACE LAYER. NO MILLING SHALL BE LEFT FOR A PERIOD OF TIME GREATER THAN 48 HOURS BEFORE A
STREET IS TO BE PAVED OR RESURFACED.
14.COMMON OPEN SPACE SHALL BE OWNED & MAINTAINED BY HOMEOWNERS ASSOCIATION.
15.ANY SPECIALITY STREET SIGNS INCLUDING POSTS SHALL BE SUBMITTED TO THE HARNETT COUNTY FOR REVIEW AND APPROVAL PRIOR TO
INSTALLATION.
16.ALL PUBLIC AND PRIVATE EASEMENTS SHALL BE RECORDED AS PART OF THE FINAL PLAT OF THE SUBDIVISION. EASEMENTS BASED OF CENTER
OF UTILITY OR PIPE SHALL BE PER AS-BUILT LOCATIONS.
17.AREAS OF PARENT PARCEL THAT ARE NOT SUBDIVIDED TO CREATE SINGLE FAMILY RESIDENTIAL LOTS ARE TO REMAIN AS ONE PARCEL TO BE
OWNED AND MAINTAINED BY THE HOME OWNERS ASSOCIATION OF THE NEIGHBORHOOD.
19.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS SHALL BE TO THE LATEST EDITION OF THE HARNETT COUNTY DEPT.
OF PUBLIC UTILITIES WATER & SEWER ORDINANCE AND THE UTILITY MASTER PLAN.
20.ALL WATER MAINS SHALL BE PUBLIC UTILITIES.
21.CONTRACTOR SHALL CONTACT HARNETT COUNTY UTILITIES PRIOR TO MAKING CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE.
22.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER EXTENSION PERMIT ISSUED BY NCDENR - PUBLIC WATER SUPPLY.
23.WATER MAINS SHALL BE CLASS 150 C900 PVC I.A.W. AWWA C900 OR THICKNESS CLASS 50 DIP PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED.
DUCTILE IRON PIPE WATER MAINS SHALL BE CLASS 350 DIP I.A.W. AWWA C-151 WITH PUSH ON JOINTS I.A.W. AWWA C-111. DIP SHALL BE
CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W. AWWA C-104. ALL DIP BURIED PIPE SHALL HAVE AN BITUMINOUS
EXTERIOR COATING I.A.W. AWWA C-151. MINIMUM BURIAL DEPTH FOR WATER MAIN IS 36 INCHES BELOW FINISHED GRADE. ALL FITTINGS SHALL BE
MECHANICAL JOINTS I.A.W. AWWA C-111.
24.ALL WATER SERVICES TO LOTS SHALL BE 3/4" BLUE POLY TUBING W/TRACER WIRE. MINIMUM BURIAL DEPTH FOR WATER SERVICES IS 24 INCHES.
25.SANITARY SEWER MAINS SHALL BE SDR-35 PVC I.A.W. ASTM D-3034-98 TYPE PSM OR CLASS 250 DIP PUSH ON JOINTS I.A.W. AWWA C-150 AND C-151
WHEN NOTED. DIP SHALL BE LINED WITH PROTECTO 401 CERAMIC EPOXY OR APPROVED EQUAL.
26.ALL SANITARY SEWER SERVICES TO LOTS SHALL BE 4" SCH-40 PVC.
27.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY UTILITY MUST BE ADJUSTED TO MEET SEPARATION REQUIREMENTS.
28.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH TRACER WIRE PER HARNETT COUNTY STANDARDS.
29.PRIVATE UTILITIES (TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES.
30.ELECTRICAL TRANSFORMERS SHALL NOT BE LOCATED WITHIN REQUIRED LANDSCAPED BUFFERS.
31.ALL ELECTRICAL THROUGHOUT THE SUBDIVISION SHALL BE UNDERGROUND.
32.ALL UTILITIES, INCLUDING FIRE HYDRANTS, INSTALLED OUTSIDE OF THE PROPOSED ROW MUST BE IN A PUBLIC UTILITY EASEMENT.
CBU
CBU ROADWAY CENTER LINELOT LINE
RIGHT OF WAY LINESETBACK LINESCM LIMITS
VALLEY CURB & GUTTERSTANDARD CURB & GUTTER
WCR WHEELCHAIR RAMP
SIGN
STREET LIGHT
SPILL CURB & GUTTER
CLUSTER MAILBOX UNIT
EASEMENT
FENCE
m a in st.60' R/Wmain st.60' R/Wbo
y
ki
n
r
d.
V
A
R
I
A
B
L
E
W
I
D
T
H
R
/
W
LIND
A
N
E
W
T
O
N
Y
O
U
N
G
MICH
A
E
L
L
Y
O
U
N
G
PIN:
0
6
8
0
-
0
8
-
2
6
1
7
D.B.3
0
0
3
,
P
G
.
6
7
4
ZON
I
N
G
:
R
A
-
3
0
BRY
A
N
K
B
L
I
N
S
O
N
BET
H
M
B
L
I
N
S
O
N
PIN:
0
6
7
0
-
9
8
-
9
8
6
9
D.B.
1
8
0
1
,
P
G
.
3
2
6
ZONI
N
G
:
R
A
-
3
0
BRYA
N
K
B
L
I
N
S
O
N
BET
H
M
B
L
I
N
S
O
N
PIN:
0
6
7
0
-
9
9
-
6
0
1
8
D.B.
1
8
0
1
,
P
G
.
3
2
6
ZONI
N
G
:
R
A
-
3
0
CHA
R
L
E
S
H
E
N
N
I
S
BAR
B
A
R
A
O
E
N
N
I
S
PIN:
0
6
7
0
-
8
9
-
9
8
2
2
D.B.
2
7
4
5
,
P
G
.
8
ZON
I
N
G
:
R
A
-
3
0
CH
A
R
L
E
S
H
E
N
N
I
S
BARB
A
R
A
O
E
N
N
I
S
PIN:
0
6
7
1
-
9
0
-
4
5
9
2
D.B.2
1
4
1
,
P
G
.
5
4
ZONI
N
G
:
R
A
-
3
0
KAT
H
Y
M
C
U
N
H
A
FABI
A
N
O
C
U
N
H
A
PIN:
0
6
8
1
-
0
0
-
7
1
8
5
D.B.
3
9
7
9
,
P
G
.
8
8
9
ZONI
N
G
:
R
A
-
3
0
WxWxWxWxWxWxWxW xWx WxPP
PP
PP
PP
PP
PP
PP
Wxm itchellrd .CBU ROADWAY CENTER LINELOT LINE
RIGHT OF WAY LINESETBACK LINESCM LIMITS
VALLEY CURB & GUTTERSTANDARD CURB & GUTTER
WCR WHEELCHAIR RAMP
SIGN
STREET LIGHT
SPILL CURB & GUTTER
CLUSTER MAILBOX UNIT
EASEMENT
FENCE
CBU
WATER LINESANITARY SEWER LINE
STORM DRAIN LINE
FIRE HYDRANT ASSEMBLY
GATE VALVE
TEETHRUST (REACTION) BLOCKINGBLOW OFF VALVE
WATER METER / SERVICESANITARY CLEANOUT / SERVICE
SANITARY MANHOLE
FLARED END SECTION
RISER STRUCTURE
YARD INLETCATCH BASIN
OPEN THROAT YARD INLET
BACKFLOW PREVENTERFMFMFMFMFMFMFMFMFMFMFMFMFM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM
FM
FM
FM FM FM
F
M FM FMFMFMFMFMFMFMWWWW WWW
WW
SS SSSS SSSSSS SSSSSSSSSSFMFM
W
WWWWWDATE:FILE NO.HORZ. SCALE:ORIG. SHEET SIZE:REVISIONSENGINEERINGCurry205 S. Fuquay AvenueFuquay-Varina, NC 27526T (919) 552-0849F (919) 552-2043CURRY ENGINEE R S
N O R TH CAROLINAEST.10NC LIC. NO. P-0799Z:\PROJECTS FOLDER-ZEBULON\2021\2021-009 DAVIDSON HOMES - BUIES CREEK\PLANS\PRELIMINARY SUBDIVISION\SHEET FILES - SINGLE FAMILY\C3.0 OFFSITE FORCE MAIN PLAN.DWGPLOTTED: 10/20/2021 3:17 PM24 x 36RETREAT AT NORTH MAINSEAL
PRELIMINARY
FOR REVIEW ONLY OCTOBER 20, 20212021-009C3.01" = 200'OFFSITE FORCE MAIN PLANNOT FOR CONSTRUCTION
N
200'400'
SCALE IN FEET
100'200'
SCALE: 1 IN = 200 FT
HORIZONTAL
0
EXISTING HARNETT COUNTY
SEWER LIFT STATION #8 TO
BE UPGRADED
RETREAT AT NORTH MAIN
TOWNES AT NORTH MAIN
PROPOSED 4" FORCE MAIN
PROPOSED RETREAT AT NORTH
MAIN PUMP STATION
G R E G O R Y C I R .
FORCE MAIN TO BE INSTALLED
INSIDE PUBLIC RIGHT-OF-WAY IN
ROADWAY GRASS SHOULDER
NUTT PROPERTY - FUTURE
TOWNHOME DEVELOPMENT -
FORCE MAIN TO CONNECT TO
GRAVITY SEWER MANHOLE