HomeMy WebLinkAboutFinal_CE_TM Sewer to Davidson Homes_2021-10-05Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Page 2
After considering the diversion of flow from Main Street, west to the pump station, it was determined that
the best feasible alternative would be to pump flow from the project site south along Gregory Circle to the
Nutt Property which is currently being developed. From the Nutt property, flow would discharge to Pump
Station SLS 8.
See Appendix B for figures that depict the proposed and existing infrastructure necessary to achieve this
modified option.
2.2.1 SLS 8
The capacity of the HRW SLS 8 is a critical component of the proposed service strategy. HRW confirmed the
following data for SLS 8 to both Timmons Group (Engineer for Buies Creek Townhomes being developed on
the Nutt property) and HIGHFILL.
Table 2.1 – HRW SLS 8
Timmons Group reported a measured drawdown capacity at SLS 8 of 135.7 GPM and a paper flow for the
Buies Creek Townhomes project of 30 GPM peak. Considering the flows provided by HRW, a peaking
factor calculation adapted from the 10-State Standards population based peak factor chart using 100
gallons per day per capita unit flow was used to project the peak flow from the existing service area
tributary to SLS 8. That calculation is as follows:
Peaking Factor (PF) = (18 + ((sqrt(Q))/316)) / (4 + ((sqrt(Q))/316))
o Q: Average Daily Flow in GPD = 8,000 GPD
o PF = 4.27
The available capacity at SLS 8 is calculated as follows:
Available Capacity = 97.2 – 30 – (5.6 x 4.27) = 43.3 GPM
As a result, adding the 30 GPM proposed from the Buies Creek Townhomes will leave 43.3 GPM available
at SLS 8. (Considering the drawdown capacity of 135.7 GPM measured by Timmons Group, 81.8 GPM of
available capacity potentially remains. Although this may require permitting with the NCDEQ to utilize.)
Peak hourly flow calculated for the Davidson Home development of 153,000 GPD converts to 106.3 GPM
(153,000 GPM / (24 hr/day) / (60 min/hr)). Neither SLS 8 firm capacity nor measured drawdown capacity
are sufficient to receive the 106.3 GPM peak flow.
2.2.2 SLS 8 Upgrade
An upgrade at SLS 8 is necessary to make the alternative feasible. Adding the calculated peak hourly flow
from the Davidson Homes Development to the Buies Creek Townhomes peak and the current peak
results in a targeted minimum capacity for SLS 8.
Target Capacity = 106.3 + 30 + (5.6 x 4.27) = 160.2 GPM
o Round up to 165 GPM for future lift station design considerations
Permitted Capacity
(GPM)
Average Day Flow
(GPM)
Max Day Flow
(GPM)
Force Main Dia.
(IN)
97.2 5.6 24.3 4
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Page 3
Capacity of the force main can limit the ultimate capacity of the lift station. The 4-inch force main
capacity at minimum, intermediate and maximum velocities.
Table 2.2 – 4-inch Force Main Capacity
165 GPM produces a velocity of 4.22 ft/sec in a 4-inch force main which is within the acceptable range of
2 – 8 ft/sec.
Lidar contour data, GIS force main route and the target capacity were used to generate a system curve
for SLS 8. Using 165 GPM as the future operating point, the TDH calculated reached approximately 115 ft.
The existing pumping equipment is not expected to be capable of achieving this operating condition.
Coordination with the Gorman Rupp sales representative resulted in a future pump selection that the
station could be retrofitted with to increase performance to the necessary condition.
Proposed pump data is included in Appendix C.
2.2.3 Downstream Sewer Capacity
The SLS 8 force main discharges to an 8-inch gravity sewer main on the west side of the Campbell
University campus. This main conveys flow west along Judge Taylor Road to Leslie Campbell Avenue then
south across Highway 421. On the south side of Highway 421, the 8-inch main connects to a 12-inch
gravity main that ultimately discharges into the HRW SLS 10B. A total distance of approximately 2,200
linear feet of 8-inch gravity sewer exists between the force main discharge location and the 12-inch
gravity main. Per HRW GIS records, some segments of the 8-inch gravity are installed at the minimum
allowable pipe slope of 0.40%.
HRW requires that calculated peaks flow not exceed pipe capacity at 2/3 full. For an 8-inch pipe installed
at minimum grade using Mannings friction factor of n=0.013, this is calculated to be 328,300 GPD.
A roof top survey was completed to evaluate the potential flow from existing services that are tributary to
the 8-inch gravity mains. It appears that portions of the drainage area include University buildings.
Determining paper flow for these facilities can be challenging as their capacity and uses are not always
easily determined. A preliminary tally of the structures within the drainage area results in an expected
paper flow of 166,250 GPD peak.
With the future peak flow from SLS 8 at 165 GPM, or 237,600 GPD and 166,250 GPD peak flow calculated
from the service area tributary to the existing 8-inch gravity sewer, the 2/3 pipe full capacity limitation is
exceeded by 75,550 GPD. The anticipated peak flow however, is well below the calculated full pipe
capacity of 490,000 GPD.
Appendix D includes a schematic of the service area of the 8-inch gravity sewer downstream of SLS 8
along with a table of the flows projected in the paper flow analysis.
The 8-inch gravity discharges to a 12-inch gravity main on the south side of Hwy 421. If installed at a
minimum slope of 0.22% a nominal 12-inch diameter gravity main has a capacity of 864,000 GPD flowing
2/3 full. Projected peak flow from the properties tributary to the 12-inch main, based on GIS data,
reaches approximately 166,250 GPD. Considering this along with the current (166,250 GPD) and future
Velocity (ft/sec) 2.0 5.0 8.0
Capacity (GPM) 78 195 313
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Page 4
(237,600 GPD) flows upstream, the 12-inch gravity has ample capacity to receive flow from the Davidson
Homes project without exceeding the HRW 2/3 pipe full limitation.
Appendix D includes a table of the flows projected for the existing services tributary to the 12-inch gravity
main.
2.2.4 Gravity from SLS 8
Currently, the Buies Creek Townhomes project is planning 8-inch gravity sewer from SLS 8 to their site. Deeded
easements will be provided to give HRW access for operation and maintenance of the mains on the property.
This gravity system is proposed to receive flow from the future Davidson Homes force main. A short extension
will bring the gravity sewer from the Townhomes site to within the public right of way along Gregory Circle. As
described above, an 8-inch gravity main installed at 0.40% minimum slope can convey 340 GPM peak flow.
Nearly 110 GPM from the Davidson Homes development and 30 GPM from the Buies Creek Town Homes
leaves approximately 200 GPM available for additional development.
Although SLS 8 would require further upgrade, this new 8-inch gravity sewer from SLS to Gregory Circle would
support additional development. The table below depicts volumes of development potentially supported for
an 8-inch as currently proposed and for 10-inch and 12-inch in the event HRW desires to upsize it in preparation
for future growth opportunities.
Table 2.3 – Future Development new Gravity Sewer from SLS 8 to Gregory Circle
Approximately 200 acres of undeveloped property exists that will be tributary to the new gravity sewer main.
This area could likely support additional development. Upsizing the gravity main at this time may be desired
by HRW if continued development is anticipated.
Appendix E includes a schematic of the service alternative with acreage of undeveloped properties upstream
of Gregory Circle that may be identified for future development.
Section 3 - Opinion of Probable Construction Cost (OPCC)
A OPCC has been developed for serving the proposed development via SLS 10B and the western outfall to
SLS 8. Collectively, about $1,430,000 is projected to make the minimum upgrades necessary.
Appendix F includes detailed OPCCs for each segment of the sewer service alternative.
Section 4 - Conclusion
Development of the proposed project by Davidson Homes on the north side of Buies Creek is expected to
add 153,000 GPD peak flow to the HRW wastewater collection system. Flow will be conveyed to the HRW
collection system via a new pumping station located on the site. From the pump station and new force
main will extend south along Gregory Circle and discharge into new gravity sewer being installed to serve
Type of
Development
# Additional Units,
8-inch Gravity Sewer
# Additional Units, 10-inch
Gravity Sewer
# Additional Units,
12-inch Gravity Sewer
3 bed residential 320 608 976
2 bed residential 480 912 1,464
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Page 5
the Buies Creek Townhomes project located on the Nutt Property. This gravity sewer will discharge in to
the existing HRW pump station SLS #8.
SLS #8 will require an upgrade to the pumping equipment to increase pumping capacity from its current
permitted capacity of 97.2 GPM to 165 GPM. The existing 4-inch force main is not expected to require any
modifications.
The SLS #8 force main discharges to existing 8-inch gravity sewer that has a capacity in accordance with
HRW 2/3 pipe full capacity limitation of 328,300 GPD. The projected peak flow is expected to exceed this
rated capacity by 23%, however, the pipe full capacity of 490,000 GPD is sufficient to convey the additional
flows.
From the 8-inch gravity sewer, flow discharges to a 12-inch gravity main which has sufficient capacity in
accordance with HRW guidelines to convey the additional flows to HRW pump station SLS 10B.
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Appendix A
Appendix A
Highfill Memorandum, Sewer Analysis Summary
Harnett County GIS, Harnett County Public Utilities
Ha rn ett GIS
L E G E N D
Recycle Center
Landfills
Surrounding County Boundaries
Federal Property
City Limits
Harnett County Boundary
Airport
MajorRoads
Interstate
NC
US
Roads
Railroad
Parcels
CapeFearRiverNOT FOR LEGAL USE0 0.15 0.3 0.450.075 Miles
1 inch = 1,750 feet
²
April 15, 2021GIS/E-911 Addressing
61,200
162,200
379,200 379,200 379,200
640,000
153,000
405,500
1,483,500
1,404,000 1,404,000
1,600,000
864,000
392,000
864,000 864,000 864,000
2,020,000
0
500000
1000000
1500000
2000000
Proposed Davidson
Homes to Main St. 8-
inch Sewer
Main St. 8-inch Sewer to
12-inch Sewer at Traffic
Circle
Traffic Circle to Meter
Site (215 Marshbanks
St.)
Meter Site Comparison
(215 Marshbanks St.)
Meter Site to SLS 10B SLS 10B Comparison
Existing Conditon, Buies Creek Sewer
Ex ADF (gpd)
Ex MDF (gpd)
Ex Max Day Capacity (gpd)
61,200
162,200 219,200 219,200 219,200
480,000
153,000
405,500
565,500
486,000 486,000
1,200,000
864,000
392,000
864,000 864,000 864,000
2,020,000
0
500000
1000000
1500000
2000000
Proposed Davidson
Homes to Main St. 8-
inch Sewer
Main St. 8-inch Sewer to
12-inch Sewer at Traffic
Circle
Traffic Circle to Meter
Site (215 Marshbanks
St.)
Meter Site Comparison
(215 Marshbanks St.)
Meter Site to SLS 10B SLS 10B Comparison
SLS 4 Relocation, Buies Creek
Ex ADF (gpd)
Ex MDF (gpd)
Ex Max Day Capacity (gpd)
61,200
162,200 162,200 162,200 162,200
480,000
153,000
405,500 405,500
486,000 486,000
1,200,000
864,000
392,000
864,000 864,000 864,000
2,020,000
0
500000
1000000
1500000
2000000
Proposed Davidson
Homes to Main St. 8-
inch Sewer
Main St. 8-inch Sewer to
12-inch Sewer at Traffic
Circle
Traffic Circle to Meter
Site (215 Marshbanks
St.)
Meter Site Comparison
(215 Marshbanks St.)
Meter Site to SLS 10B SLS 10B Comparison
SLS 4 & SLS 7 Relocation, Buies Creek
Ex ADF (gpd)
Ex MDF (gpd)
Ex Max Day Capacity (gpd)
Harnett County GIS, Harnett County Public Utilities
Ha r nett GI S
Recycle Center
Landfills
Surrounding County Boundaries
Federal Property
City Limits
Harnett County Boundary
Airport
MajorRoads
Interstate
NC
US
Roads
Railroad
Parcels
CapeFearRiver
0 1,300 2,600650Feet
1 inch = 1,505 feet
²
June 30, 2021NOT FOR LEGAL USE .GIS/E-911 Addressing
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Appendix B
Appendix B
Proposed and Existing Infrastructure to Achieve Modified Service Option
Harnett County GIS, Harnett County Public Utilities
Ha rn ett GIS
L E G E N D
Recycle Center
Landfills
Surrounding County Boundaries
Federal Property
City Limits
Harnett County Boundary
Airport
MajorRoads
Interstate
NC
US
Roads
Railroad
Parcels
CapeFearRiverNOT FOR LEGAL USE0 0.15 0.3 0.450.075 Miles
1 inch = 1,750 feet
²
April 15, 2021GIS/E-911 Addressing
Harnett County GIS, Harnett County Public Utilities
Ha r nett GI S
Recycle Center
Landfills
Surrounding County Boundaries
Federal Property
City Limits
Harnett County Boundary
Airport
MajorRoads
Interstate
NC
US
Roads
Railroad
Parcels
CapeFearRiver
0 1,300 2,600650Feet
1 inch = 1,505 feet
²
June 30, 2021NOT FOR LEGAL USE .GIS/E-911 Addressing
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Appendix B
Appendix C
Potential Pump for SLS 8
Copyright Gorman‐Rupp Pumps 2020
PAGE 2525Specification Data
PUMP SPECIFICATIONS
Size: 4” x 3” (101,6 mm x 76,2 mm).**
Casing: Gray Iron 30.
Maximum Operating Pressure 127 psi (876 kPa).*
Semi‐Open Type, Two Vane Impeller: Ductile Iron 65‐45‐12.
Handles 2.50” (63,5 mm) Diameter Spherical Solids.
Impeller Shaft: Alloy Steel 4150.
Replaceable Eradicator Wear Plate: Carbon Steel ASTM A36.
Removable Adjustable Cover Plate: Gray Iron 30.
Removable Inspection Cover Plate: Gray Iron 30.
Externally Removable Flap Valve: Neoprene w/Nylon and Steel
Reinforcing.
Suction Flange/Flap Valve Seat: Gray Iron 30.
Bearing Housing: Gray Iron 30.
Seal Plate: Gray Iron 30.
Shaft Sleeve: Alloy Steel 4130.
Radial and Thrust Bearings: Open Double Row Ball.
Bearing and Seal Cavity Lubrication: SAE 30 Non‐Detergent Oil.
Gaskets: Buna‐N, Compressed Synthetic Fibers, Vegetable Fiber, PTFE,
Cork and Rubber.
O‐Rings: Buna‐N.
Hardware: Standard Plated Steel.
Brass Pressure Relief Valve.
Bearing and Seal Cavity Oil Level Sight Gauges.
Optional Equipment: Automatic Air Release Valve. High Pump Temperature
Shutdown Kit. Cartridge Seal w/Stainless Steel Sleeve. 120/240 Volt Casing
Heater.
**Optional Gray Iron 30 Flanges Available as Follows (See Price Sheets):
4” and 3” Female NPT Suction/Discharge Flange Kits.
4” and 3” ASA Suction/Discharge Spool Flange Kits.
200 mm and 150 mm DIN 2527 (PN 16) Suction/Discharge Spool
Flange Kits.
Sec. 55
Self Priming Centrifugal Pump
Model V3C60SC‐B
Size 4” x 3”
SEAL DETAIL
Cartridge Type, Mechanical, Oil‐Lubricated,
Double Floating, Self‐Aligning. Silicon Carbide
Rotating and Stationary Faces. Stainless Steel
316 Stationary Seat. Fluorocarbon Elastomers
(DuPont Viton or Equivalent). Stainless Steel
18‐8 Cage and Spring. Maximum Temperature
of Liquid Pumped, 160 F (71 C).*
*Consult Factory for Applications Exceeding
Maximum Pressure and/or Temperature In
dicated.SEAL ASSEMBLY
IMPELLER
IMPELLER
SHAFT
DISCHARGE
COVER
PLATE
SUCTION
FLANGE/FLAP
VALVE SEAT
CASING
FILL
PORT
PRESSURE
RELIEF
VALVE
JULY 2020Ultra V Series Basic Pump
VARIOUS PATENTS APPLY
GORMAN‐RUPP PUMPS
www.grpumps.com
Specifications Subject to Change Without Notice Printed in U.S.A.
ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎ
ÎÎ
Î
Î
Î
Î
Î
ÎÎ
ÎÎ
Î
Î
Î
Î
ÏÏÏ
Ï
Ï
ÏÏ
ÏÏÏÏ
ÏÏ
ÏÏÇ
Ì
Ì
Ì
ÌÇ
ÇÇ
ÇÇ
Ç
Ç
Ç
ÇÇÇ
Ç
ÇÇÇ
Ç
Ç
Ç
Ç
Ç
Ç
ÇÇÇ
ÇÇ
Ç
Ç
ÇÇ
ÇÇ
ÇÇÇ
ÇÇÇ
Ç
Î
ÎÏ
Ï Ç
ÇÌ
Ì
Ì Ç
Ç
Ç
Ï
ÏÌ
Ì
ÏÏ
ÏÏ
ÏÏ
ÏÏ
ÏÏ
ÌÌÌ
ÌÌÌ
ÌÌÌ
ÌÌÌ
ÌÌÌ
Ï
Ï
Ï
Ï
ÎÎ
ÎÎ
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎ
ÎÎÎ
ÎÎ
ÎÎ
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎÎ
Ï
Ï
ÏÏÏ
ÏÏÏ
ÏÏÏ
ÏÏÏÇ
Ç
Ç
Î
Î
Î
Ï
Ï Ç
Ç
Ç
Ì
Ï
Ï
Ï
Ï
Ï
Ï
Ï
Ï
Ï
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ç
Ç
INSPECTION
COVER
BALL BEARINGS
SEAL PLATE
FLAP
VALVE
WEAR PLATE
LIP SEALS
Equipped With
PHOTO NOT AVAILABLE AT TIME OF PUBLISHING
Copyright Gorman‐Rupp Pumps 2020
Specification Data
APPROXIMATE
DIMENSIONS and WEIGHTS
SECTION 55, PAGE 2525
NET WEIGHT: 650 LBS. (295 KG.)*
SHIPPING WEIGHT: 700 LBS. (317 KG.)*
EXPORT CRATE: 13.5 CU. FT. (0,38 CU. M.)
*WEIGHTS DO NOT INCLUDE OPTIONAL FLANGE KITS.
DIMENSIONS:
INCHES
[MILLIMETERS]
18.00/[457.2] RECOMMENDED FOR REMOVAL OF BACK COVER PLATE
10.50/[266.7] REQUIRED FOR REMOVAL OF BACK COVER PLATE*
.69/[17.5] DIA
4 HOLES
.38/[9.6] X .19/[4.8]
X 4.00/[101.6] LG
USEABLE KEYWAY
*
OPTIONAL
3.00 NOMINAL
ASA OR 80 MM
DIN 2527 (PN16)
DISCHARGE SPOOL
FLANGES
STANDARD
SUCTION:
4.00-8 NPT
OPTIONAL
4.00 NOMINAL
ASA OR 100 MM
DIN 2527 (PN16)
SUCTION SPOOL
FLANGES
20.00[ 508.0]
.75[ 19.0]
9.25[235.0]
18.50[ 469.9]
19.88[ 504.8]
30.66[ 778.8]TO ASAFLANGE
9.38[238.1]1.50[ 38.1]DIA
4.93[ 125.1]
1.94[49.1]
1.00[25.4]10.75[ 273.0]12.64[ 321.1]APPROX
35.55[ 903.0]TO ASA FLANGE
30.71[ 780.0]TO STANDARDNPT SUCTION
35.40[ 899.3]TO DIN FLANGE
9.25[ 235.0]
24.62[ 625.5]
25.85[ 656.6]TO NPTFLANGE28.22[ 716.9]30.69[ 779.6]TO DINFLANGE
60 HERTZ
PERFORMANCE
BASED ON
WATER
GORMAN‐RUPP PUMPS
www.grpumps.com
Specifications Subject to Change Without Notice Printed in U.S.A.
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Appendix D
Appendix D
Existing Flow Evaluation, 8-inch Gravity Sewer Downstream of SLS 8
Preliminary Downstream Paper Flow Evaluation
9/24/2021, cde
Property ID Description Acreage Flow Rate ADF
4579
Historic, JA Campbell House (assume 2
employees)1.33 25 gpd/employee 50
4695 1639 SF residence, Cambell University 360 gpd 360
25 2448 SF residence 0.67 360 gpd 360
4624 1767 SF residence 0.45 360 gpd 360
4644 1296 SF residence 0.44 360 gpd 360
4678 3005 SF residence 0.84 360 gpd 360
4744 1932 SF residence 0.74 360 gpd 360
4919 Exxon Gas Station, Hwy 421 (assume 5 fixtures)0.88 250 gal/fixture 1250
230 & 260 Luby Wood Hall (174 rooms)9.07
60 gpd (2T boarding
school)10440
Bob Barker Hall (300 residents)
60 gpd (2T boarding
school)18000
70 2211 SF residence 1.11 360 gpd 360
90 2152 SF greek house 0.62 360 gpd 360
141 & 159 1176 SF residence 0.67 360 gpd 360
181 2183 SF greek house 0.66 360 gpd 360
207 & 209 2421 SF Greek House 0.72 360 gpd 360
233 1816 SF residence 1.05 360 gpd 360
271 Church (assume 400 seats)2.52 5 gal/seat 2000
Child Care (100 children & employees assumed)25 gpd/person 2500
53 3528 SF residence 1.17 360 gpd 360
89 1276 SF residence 0.54 360 gpd 360
91 1720 SF residence 0.38 360 gpd 360
129
4596 SF John Pearson Infirmary (2 practitioners
assumed)0.47 250 gpd/practitioner 500
220 1984 SF residence 0.24 360 gpd 360
188 984 SF residence 0.37 360 gpd 360
172 1326 SF residence 0.29 360 gpd 360
152 1550 SF residence 0.44 360 gpd 360
130 1960 SF greek house 0.39 360 gpd 360
77 2371 SF residence 1.08 360 gpd 360
99 1435 SF residence 1.1 360 gpd 360
Leland Circle Apts (43 units), Campbell University 5.77 240 gpd/unit 10320
197 1678 SF residence 0.53 360 gpd 360
Creekside Apts (9 units), Campbell University 1.04 240 gpd/unit 2160
Butler Chapel (approx 400 seats), Campbell
University 5 gal/seat 2000
McLeod Admission & Financial Aid Center (50
employees assumed)25 gpd/employee 1250
Marshbanks Hall, Campbell University (10% of
6,500 enrollment assumed)10 gpd/student 6500
Day Hall, Campbell University (50 employees
assumed)25 gpd/employee 1250
Subtotal ADF (GPD)66,500
Subtotal MDF (GPD, PF = 2.5)166,250
*Flow rates are projections based on roof top evaluation using aerial imagery only.
Actual uses, sizes and resulting flow projections may vary.
Preliminary Downstream Paper Flow Evaluation - Tributary to 12-inch Gravity
9/24/2021, cde
Property ID Description Acreage Flow Rate ADF
36 Single Family Homes, Lynch Ave, Powell Ave,
Burkot Rd, Pearson Rd (assume 3 bedrooms)360 gpd 12960
Stadium View Student Housing (85 parking
spaces = 85 rooms)
60 gpd (2T boarding
school)5100
Barker Lane Stadium (5,500 capacity)5 gpd/seat 27500
Stadium Field House (125' x 150')50 gpd/100 sqft 9375
Subtotal ADF (GPD)54,935
Subtotal MDF (GPD, PF = 2.5)137,338
*Flow rates are projections based on roof top evaluation using aerial imagery only.
Actual uses, sizes and resulting flow projections may vary.
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Appendix E
Appendix E
Future Service Potential North of Gregory Circle
Harnett County GIS, Harnett County Public Utilities
Ha r nett GI S
Recycle Center
Landfills
Surrounding County Boundaries
Federal Property
City Limits
Harnett County Boundary
Airport
MajorRoads
Interstate
NC
US
Roads
Railroad
Parcels
CapeFearRiver
0 1,300 2,600650Feet
1 inch = 1,505 feet
²
June 30, 2021NOT FOR LEGAL USE .GIS/E-911 Addressing
Technical Memorandum
Sewer Capacity Analysis, Davidson Homes – Buies Creek, NC
HIGHFILL | Appendix E
Appendix F
Detailed OPCCs
OPINION OF PROBABLE CONSTRUCTION COST Jun-21
Buies Creek Sewer Capacity Increase by: CDE 7/1/2021
HIEPC PROJECT NO.: CUR2101 chk:
Extended
Item No Units Mat'l/Equip Lab Equip+Lab Total
New PS & FM by Davidson Homes
Pump Station (110 gpm)
Misc. site work (clearing, grading, bollards, fill dirt, excavation, etc.)1 LS 25,000$ 25,000$
Fence 200 LF 50$ 10,000$
16' Fence double seing gate 1 EA 5,000$ 5,000$
Wetwell, 6' dia concrete 1 LS 30,000$ 30,000$
Valve vault 1 LS 22,000$ 22,000$
Excavation 1 LS 12,000$ 12,000$
Concrete (pads, supports, etc.) 25 CY 500$ 12,500$
Duplex submersible pumps, guide rails, base elbows, controls, etc.1 LS 57,600$ 57,600$
Misc. piping, guages, spool pieces, fittings 1 LS 20,000$ 20,000$
4-inch plug valve 2 EA 5,000$ 10,000$
4-inch check valve 2 EA 5,000$ 10,000$
Yard hydrant, BFP & water meter 1 LS 7,500$ 7,500$
Gravel surface 65 TON 50$ 3,250$
Painting 1 LS 8,000$ 8,000$
Engine driven standby generator with ATS 1 LS 75,000$ 75,000$
SCADA 1 LS 12,000$ 12,000$
Electrical installation 1 LS 75,000$ 75,000$
Force Main
4-inch SSFM 8000 LF 35$ 280,000$
12-inch casing by bore & jack 100 LF 300$ 30,000$
Air release valve 1 EA 7,500$ 7,500$
Misc driveway repairs 90 SY 40$ 3,600$
Stabilization stone 30 TON 50$ 1,500$
Select backfill 120 CY 50$ 6,000$
Erosion Control 1 LS 25,000$ 25,000$
Gravity Sewer
8-inch Gravity sewer 300 LF 80$ 24,000$
4' Dia SSMH (SSFM discharge) 1 EA 7,500$ 7,500$
Mobilization/Bonds/Insurance 5% 38,998$
Sub-Total 819,000$
Contingency 20% 164,000$
Total Construction (2021 dollars) 983,000$
DRAFT
CUR2101_DH PS FM OPCC_CE_2021-07-01
HIEPC Proj No. KHA0601
Printed: 9/8/2021
OPINION OF PROBABLE CONSTRUCTION COST Jun-21
Buies Creek Sewer Capacity Increase by: CDE 7/1/2021
HIEPC PROJECT NO.: CUR2101 chk:
Extended
Item No Units Mat'l/Equip Lab Equip+Lab Total
SLS8 upgrade to 200 gpm
Pump and Controls Upgrade 1 LS 250,000$ 250,000$
Standby Generator Upgrade 1 LS 60,000$ 60,000$
Electrical upgrades 1 LS 45,000$ 45,000$
Mobilization/Bonds/Insurance 5% 15,500$
Sub-Total 371,000$
Contingency 20% 74,000$
Total Construction (2021 dollars) 445,000$
DRAFT
CUR2101_DH PS FM OPCC_CE_2021-07-01
HIEPC Proj No. KHA0601
Printed: 9/8/2021