HomeMy WebLinkAboutFire Protection.Hydrant Flow TA_CC app and Info Page 1 of 2 TEXT AMENDMENT REQUEST FORM (Internal) Development Services 108 E. Front Street P.O. Box 65, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Planning Board: March 7, 2022 County Commissioners: March 21, 2022 Applicant Information: Case Number PLAN 2112-0004 Applicant: Name: Harnett County Development Services Address: 108 E Front St City/State/Zip: Lillington NC, 27546 E-mail: Phone: 910-893-7525 Type of Change New Addition Revision Ordinance: Unified Development Ordinance Article: VII Section: 6.4.1 Current Text: See attached Proposed Text: (Attach additional sheets if necessary) See attached Reason for Requested Change: To amend Harnett County’s U.D.O. in order to add a specifics such as a ‘duration for water flow’ as associated with fire hydrants and fire protection. Suggested Statement-of-Consistency: (Staff concludes that…) The requested Text Amendment is compatible with Harnett County regulatory documents as well as the National Fire Protection Association regulations. Therefore, it is recommended that this Text Amendment request be APPROVED. Additional Information: At their March 7th meeting, the Harnett County Planning Board voted 4-0 to recommend approval of this of the Text Amendment based on need to be more specific with fire hydrant requirements. - No one spoke in opposition. Page 2 of 2 ATTACHMENT 1 Red text is proposed, Black text is existing ARTICLE VII. DEVELOPMENT DESIGN GUIDELINES 6.1 Fire Protection 6.4.1 General Fire Hydrant Requirements Adequate Fire protection shall be provided to all new subdivision developments and nonresidential new construction and expansions. The developer or subdivider shall install fire hydrants in such a manner that the development is afforded adequate fire protection as provided in this Ordinance. The regulations contained herein are intended to facilitate proper installation of required fire protection measures. A. All hydrants shall be Harnett County Public Utilities Harnett Regional Water and Fire Code Official approved, in accordance with the requirements of this Section. 1. No fire hydrant shall be installed on less than a 6 inch (6”) public main. 2. Hydrants shall have two (2) two and one half inch (2 ½”) and one (1) four and one half inch (4 ½”) connections with threads of the National Pipe Thread (NPT) type. Five inch (5”) Storz connection. 3. The upper hydrant operation stem within the bonnet shall be sealed and lubricated by means of an oil or grease bath, unless otherwise approved. The operating nut shall be pentagonal type measuring one and one half inch (1 ½”) from point to flat. Hydrants shall open left. 4. All hydrants shall be furnished with barrel and stem extensions as required for the final field location. Nominal minimum bury will be a depth of three and one half (3 ½) feet. All hydrants at finish grade shall measure 18 inches (18”) from ground to center of steamer cap. 5. Water lines servicing fire hydrants shall have at least 500 gallons of water per minute for a duration of no less than two (2) hours. 6. All fire hydrants shall be installed on a public water main if the development meets the distance specifications for connections set forth in Article VII, Section 6.2.1 of this Ordinance. B. The Fire Code Official shall approve all hydrant types and locations in new developments and any alterations to this Ordinance related to fire hydrants and fire protection. C. All fire hydrants shall be located on the right side of the roadway in which responding fire apparatus would travel into subdivisions, beginning at the main entrance to the subdivision, business, or facility.