Loading...
HomeMy WebLinkAboutBUIES CREEK 20210602 (8)NAD83BUIES CREEK TOWNHOMES TOWN HOMESPROPOSED USE: ZONING:RA-30 BUIES CREEK TOWNHOMESPROJECT: SITE DATA ENGINEER: KEITH ROBERTS, PE PHONE: 919-866-4940 RALEIGH, NC 27607 5410 TRINITY ROAD; SUITE 102 TIMMONS GROUP EMAIL: KEITH.ROBERTS@TIMMONS.COM STANCIL BUILDERS, INC TOTAL TRACT AREA:13.28 ACRES 466 STANCIL RDDEVELOPER: ANGIER, NC 27501 TOWNSHIP:LILLINGTON PHONE: 919-639-2073 SITE PLAN VICINITY MAP COVERC0.0 EXISTING IMPERVIOUS AREA:0 ACRES PROPOSED IMPERVIOUS AREA:4.40 ACRES (33.1%) 1" = 750' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C0.0-COVR.dwg | Plotted by Gibson BlakesleeFOR RE VIE W ONL Y 06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN STANCIL BUILDERS, INC 466 STANCIL RD ANGIER, NC 27501 PHONE: 919-639-2073 DEVELOPER TIMMONS GROUP 5410 TRINITY RD, SUITE 102 RALEIGH, NC, 27607 PHONE: 919-866-4940 KEITH ROBERTS, PE EMAIL: KETIH.ROBERTS@TIMMONS.COM ENGINEER Sheet List Table Sheet Number Sheet Title C0.0 COVER C1.0 EXISTING CONDITONS PLAN C2.0 SITE PLAN C3.0 UTILITY PLAN C3.1 UTILITY PLAN C4.0 GRADING PLAN C4.1 GRADING PLAN C5.0 UTILITY PROFILES C5.1 UTILITY PROFILES C5.2 UTILITY PROFILES C6.0 NOTES AND DETAILS C6.1 NOTES AND DETAILS C6.2 NOTES AND DETAILS C6.3 NOTES AND DETAILS C6.4 NOTES AND DETAILS C6.5 WET POND DETAILS C7.0 PLANTING PLAN C7.1 PLANTING PLAN C8.0 LIGHTING PLAN A101 FLOOR PLAN AND ELEVATIONS A102 FLOOR PLAN AND ELEVATIONS A103 ELEVATIONS KNOW WHAT'S BELOW.CALL 811 BEFORE YOU DIG. TOTAL TRACT IMPERVIOUS AREA:4.40 ACRES (33.1%) SITE ALL CONSTRUCTION TO BE IN ACCORDANCE WITH HARNETT COUNTY, NCDEQ, AND NCDOT STANDARDS, SPECIFICATIONS AND DETAILS SITE ADDRESS:0 GREGORY CIR 0 GREGORY CIRC, HARNETT COUNTY, NORTH CAROLINA BENTON W. DEWAR AND ASSOCIATES 5920 HONEYCUTT ROAD HOLLY SPRINGS, NC 27540 PHONE: 919-552-9813 SURVEYOR LODLODLOD LOD LODLODLO D LO D LO D LO D LOD LO D LO D LO D LO D LO D LOD L O D LOD LO D LO D LO D LOD LODLOD L O DLODLODLODLODLODLODLOD LOD 204 203202201 200 199 198 197 196195194193192 191 190 189 188 187 185 184 1701751801851901931681651701751851801 6 0 1621801851901951971751 7 2 1 7 5 1601561561571 6 0 1 7 0 163 159158157160161162N24° 1 8 ' 1 2 " W 32.1 2 ' N19 ° 3 7 ' 1 1 " W 38. 9 5 ' N26° 5 8 ' 0 1 " W 30.41 ' N30°1 5 ' 1 1 " W 34.08' N32°20' 5 3 " W 34.04' N34°58'1 2 " W 40.23' N1 7 ° 5 7 ' 5 8 " W 36. 2 2 ' S82° 2 8' 4 6" E 690. 9 7' S1 3 ° 3 8 ' 5 9 " E 13 8 6 . 7 0 'N36°45'57"E555.87'N60°13'0 4 " W 217.86' S1 3 ° 3 8 ' 5 9 " E 13 8 6 . 7 0 'S37°07'39"W597.91'S36°45'57"W31.56'N82° 1 9' 0 6" W 34.6 9' 0 SCALE 1"=60' 120'60' C1.0 EXISTING CONDITONS PLANNAD 83JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C1.0-EXIS.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. CREEK CENTERLINE EXISTING 6" WATERLINE EXISTING CULVERT AND HEADWALL EXISTING FIRE HYDRANT TO REMAIN EXISTING DITCH NELLIE H. HARDEE PIN: 0670-66-0983 ZONE: RA-30 CREEK TOP OF BANK GREG O R Y C I R C 60' RI G H T O F W A Y NOTES 1.BOUNDARY INFORMATION PROVIDED BY BEN DEWAR, PLS. 2.EXISTING TOPOGRAPHIC INFORMATION PROVIDED BY BEN DEWAR, PLS. 3.ADJACENT PROPERTY OWNERSHIP INFOMRATION PROVIDED BY HARNETT COUNTY GIS. 4.THE SUBJECT PROPERTY LIES IN ZONE X IN ACCORDANCE WITH FIRM MAP #3720066000J WITH EFFECTIVE DATE OF OCTOBER 3,2006. 5.ALL UTILITIES OR STRUCTURES NOT INDICATED FOR REMOVAL OR MODIFICATION ARE TO REMAIN AND BE PROTECTED FROM DAMAGE. 6.ALL WASTE MATERIAL GENERATED FROM CLEARING AND DEMOLITION ACTIVITIES SHALL BE DISPOSED OF OFF-SITE IN ACCORDANCE WITH WITH ALL APPLICABLE RULES AND REGULATIONS. 7.REMOVE TOPSOIL AND STOCKPILE APPROPRIATELY ON-SITE. ON-SITE TEMP. STOCKPILES SHALL BE LOCATED WITHIN CONSTRUCTION LIMITS. 8.ALL PAVEMENT OR CONCRETE TO BE REMOVED SHALL BE SAW CUT TO PROVIDE A STRAIGHT AND UNIFORM JOINT WITH NEW CONSTRUCTION. ANY EXISTING PAVEMENT, SIDEWALK, CURB & GUTTER, ETC. THAT MUST BE REMOVED TO ALLOW NEW CONSTRUCTION SHALL BE REMOVED AND REPAIRED PER THE SPECIFICATIONS AND DETAILS OR TO MATCH EXISTING CONDITIONS (WHETHER OR NOT SHOWN ON THE DRAWINGS TO BE REMOVED). UTILITY INSTALLATIONS MAY UTILIZE OPEN CUT OF PAVEMENTS UNLESS INDICATED OTHERWISE. TRENCH IN EXISTING ASPHALT SHALL BE PATCHED PER PAVEMENT REPAIR DETAIL. 9.PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC AND ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGES OCCUR, NOTIFY ARCHITECT IMMEDIATELY. 10.THE CONTRACTOR SHALL EMPLOY A QUALIFIED UTILITY LOCATOR SERVICE TO LOCATE ALL UNDERGROUND UTILITIES (INCLUDING BUT NOT LIMITED TO ELECTRICAL, TELEPHONE, GAS, CABLE, FIBER OPTIC) WITHIN THE LIMITS OF CONSTRUCTION. 11.VERIFY ALL ILLUSTRATED KNOWN UNDERGROUND ELEMENTS. EXERCISE REASONABLE EFFORTS TO PROTECT ANY UNKNOWN UNDERGROUND ELEMENTS. NOTIFY THE ARCHITECT IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO THE PROPOSED DESIGN. 12.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND OSHA REGULATIONS. 13.EXISTING MANHOLES, VALVE BOXES, VAULTS, CLEANOUTS, UTILITY POLES ETC. TO REMAIN WITHIN THE GRADING LIMITS SHALL BE ADJUSTED AS NEEDED TO FUNCTION PROPERLY WITH THE PROPOSED FINISHED GRADES (WHETHER OR NOT INDICATED TO BE MODIFIED). 14.GENERAL CONTRACTOR TO COORDINATE ALL PEDESTRIAN ACCESS PATHS, LOCATIONS, LIGHTING ETC. W/OWNER. 15.DEMOLITION AND PATCHING OF PAVEMENT AND OTHER EXISTING IMPROVEMENTS IN ADDITION TO THAT INDICATED ON THIS PLAN SHALL BE PERFORMED AS NECESSARY TO CONSTRUCT AND/OR INSTALL NEW WORK. SPRINKLER VALVE HVAC - HEATING, VENTILATION AND AIR CONDITIONING LEGEND GAS VALVE FENCE EDGE OF TREELINE PAINTED WATER LINE PAINTED TELEPHONE LINE GUY CABLE TV PEDESTAL CMF - CONCRETE MONUMENT IPS - IRON PIPE SET IRF - IRON ROD FOUND IPF - IRON PIPE FOUND TELEPHONE PEDESTAL FIRE HYDRANT LIGHT POLE POWER POLE ELECTRIC BOX PG - PAGE SF - SQUARE FEET GV - GAS VALVE YI - YARD INLET GI - GRATE INLET CB - CATCH BASIN NTS - NOT TO SCALE R / W - RIGHT-OF-WAY C / L - CENTERLINE P / L - PROPERTY LINE CI - CURB INLET PB - PLAT BOOK DB - DEED BOOK EP - EDGE OF PAVING X X X OHP OHP W W UGT UGT CMP - CORRUGATED METAL PIPE VCP - VITRIFIED CLAY PIPE RCP - REINFORCED CONCRETE PIPE HDPE - HIGH DENSITY POLYETHYLENE PIPE SPRINKLER HEAD SIGN TBC - TOP BACK OF CURB FLAG POLE GROUND LAMP STORM LINE SANITARY LINESANSAN OVERHEAD POWER LINE DIP - DUCTILE IRON PIPE MH TELEPHONE MH SANITARY MH DRAINAGE BOLLARD SPRINKLER BOX WATER VALVE GAS METER CLEAN OUT WATER METER ELECTRIC METER MH WATER YARD LIGHT S W D E T C T MH ELECTRIC PAINTED POWER LINEUGPUGP PAINTED GAS LINEGG PAINTED STORM LINESTM ROOF DRAIN AC UNIT MAILBOX DEED LINE LINE NOT SURVEYED BOREHOLE BACKFLOW PREVENTERBFP WATER VAULTVW TELEPHONE VAULTVT WELLW MONITORING WELL LSA -LANDSCAPED AREA MKF - FIBER OPTIC MARKER SIGP - SIGNAL POLE TRAFFIC CONTROL BOX TVP - TELEVISION PEDESTAL UTILITY VAULT TC FES - FLARED END SECTION MKG - GAS MARKER MNF - MAG NAIL FOUND WATER SPIGOT CP - COMPUTED POINT CP - COMPUTED EASEMENT POINT CSF - COTTON SPINDLE FOUND POWER VAULTVP VU GAS TEST LOCATION WF - WETLAND FLAG CCR - CHATHAM COUNTY RECORD WCR - WAKE COUNTY RECORDS TREE HANDICAP PARKING STORM INLET HC XXXX - SITE ADDRESS PAINTED FIBER OPTIC LINE PAINTED CABLE TV LINEUCATV UFO EXISTING WOOD LINE LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE EXISTING SANITARY SEWER PUMP STATION EXISTING SANITARY SEWER DROP MANHOLE RIM - 162.42 8" PVC IN - 153.77 SHELF - 152.06 INV. OUT - 151.02 EXISTING SANITARY SEWER WET WELL RIM - 162.25 BOTTOM - 144.35 PUMP STATION NO. 8 BUIES CREEK - COATS WATER AND SEWER DISTRICT P.C. # 2 SLIDE 101 EXISTING ROCK WALL EXISTING WOOD LINE RIGHT OF WAY EDWARD HUMPHREY D.B. 2762 PG. 308 D.B. 618 PG. 590 EDWARD HUMPHREY D.B. 3750 PG. 598 D.B. 618 PG. 590 CAMPBELL UNIVERSITY, INC. D.B. 728 PG. 830 NICHOLAS AND CYNTHIA HOLEMAN D.B. 3796 PG.308 JOYCE ANDREWS D.B. 2834 PG. 476 SUSETTE WINDSOR TRUST D.B. 3183 PG. 520 PAR K W O O D L N APPROXIMATE LOCATION OF EXISTING SANITARY SEWER EASEMENT N36°45'57"E555.87'N6 0 ° 1 3 ' 0 4 " W 21 7 . 8 6 'S13°38'59"E1386.70'N36°45'57"E555.87'S82°28'46"E 690.97' C2.0 SITE PLANJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C2.0-SITE.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN 0 SCALE 1"=40' 80'40'NAD 83KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. 18'18'24'9'9'9'VAC 9'STALL AISLE STALL TYPICAL PARKING DIMENSIONS 9 0 ° VAC NOTES: ALL DIMENSIONS ARE TO FACE OF CURB. INSTALL HC-VAN ACCORDING TO NC ACCESSIBILITY CODE. TYP 5' RADIUS UNLESS NOTED OTHERWISE THE ACCESSIBLE PARKING SPACES AND AISLES SHALL HAVE A MAX. 2% SLOPE IN ALL DIRECTIONS INCLUDING THE DIAGONAL LEGEND PROPERTY LINE PERIMETER BUFFER PROPOSED RIGHT-OF-WAY PROPOSED LOT LINE DRAINAGE EASEMENT SANITARY SEWER EASEMENT PHASE LINE PROPOSED 100 YR FLOODPLAIN PROPOSED CENTERLINE ADJACENT PROPERTY LINE EXISTING ROAD CENTERLINE EXISTING RIGHT-OF-WAY PROPOSED EOP BUILDING SETBACK EXISTING WETLANDS NEUSE RIPARIAN BUFFER CIVIC SPACE SIDEWALKS MUST BE MOUNTED WITH 7-FT MIN. VERTICAL CLEARANCE DEEP x 8-IN DIA. CONCRETE FOOTING. SIGNS MOUNTED ADJACENT TO BOTTOM OF THE SIGN ON 2-LB. GALV. STEEL U-CHANNEL POST SET IN 18-IN ALL SIGNS SHALL BE MOUNTED WITH 5-FT MIN. VERTICAL CLEARANCE TO THE TRAFFIC CONTROL DEVICES (MUTCD) AND NCDOT STANDARDS. ALL SITE SIGNAGE SHALL BE IN ACCORDANCE WITH THE MANUAL ON UNIFORM TO THE BOTTOM OF SIGN. 3. 2. 1. 12"x18" SIZE R7-1 MUTCD STD. ACCESSIBLE PARKING SIGN ALL PAVMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE MUTCD AND NCDOT STANDARDS AND THE PROJECT SPECIFICATIONS. MARKING PARKING SPACE NCDOT STD.SIZE 4-IN COLOR WHT.- TRAFFIC CONTROL NOTES 4.ALL PAVMENT MARKINGS SHALL BE RESIN TYPE PAINT AS REQUIRED BY THE COUNTY. * NO PARKING - FIRE LANE MARKING SHALL CONSIST OF A 4" SOLID YELLOW STRIPE AND 8" HIGH YELLOW TEXT "NO PARKING - FIRE LANE" AT 40' INTERVALS. STRIPING SHALL BE PLACED AS INDICATED BY THE FOLLOWING LINETYPE NO PARKING - FIRE LANE *4-IN YEL. CROSSWALK 4-IN WHT.1205.07 30"x30"R1-1STOP PAVEMENT LEGEND CONCRETE SIDEWALK, SEE DETAIL SHEET HEAVY-DUTY ASPHALT PAVEMENT, SEE DETAIL SHEET LIGHT-DUTY ASPHALT PAVEMENT, SEE DETAIL SHEET LIGHT-DUTY CONCRETE PAVEMENT, SEE DETAIL SHEET HEAVY-DUTY CONCRETE PAVEMENT, SEE DETAIL SHEET SITE PLAN SUMMARY PROJECT:BUIES CREEK TOWNHOMES DEVELOPER:STANCIL BUILDERS INC PROJECT ADDRESS:0 GREGORY CIR PIN #:0670-66-0983 JURISDICTION:BUIES CREEK ZONING:RA-30 EXISTING USE:VACANT PROPOSED USE:TOWNHOMES SETBACKS:FRONT SETBACK: 35', SIDE SETBACK: 15', REAR SETBACK: 35' FLOOD ZONE:NOT LOCATED IN FLOOD HAZARDS AREA PER FEMA MAP #3720066000J (EFFECTIVE 10/03/2006) PROPOSED LOT 1 AREA:13.29 ACRES DISTURBED AREA:7.89 ACRES EXISTING IMPERVIOUS SURFACE AREA:0.0 ACRES (0.0%) PROPOSED IMPERVIOUS AREA:4.40 ACRES (33.1%) VEHICLE PARKING SUMMARY: REQUIRED 1 SPACE PER UNIT 1 SPACE / UNIT * 72 UNITS TOTAL = 72 SPACES VEHICLE PARKING SUMMARY: PROVIDED 285 TOTAL SPACES 12 VAN ACCESSIBLE ADA SPACES REQUIRED OPEN SPACE (15%)1.99 ACRES PROPOSED OPEN SPACE 2.40 ACRES REQUIRED IMPROVED OPEN SPACE (5% OF REQUIRED)0.10 ACRES PROPOSED IMPROVED OPEN SPACE 0.14 ACRES SITE LAYOUT KEYNOTES A ACCESSIBLE WHEELCHAIR RAMP TYPE 1, SEE DETAILS B ACCESSIBLE WHEELCHAIR RAMP TYPE 1B, SEE DETAILS C ACCESSIBLE WHEELCHAIR RAMP TYPE 2, SEE DETAILS D MAIL KIOSK, SEE ARCHITECTURALS E PROPOSED DUMPSTER PAD AND ENCLOSURE; SEE DETAILS F FLUSH PAVEMENT, SEE DETAIL SHEET G ACCESSIBLE PARKING AND SIGNAGE, SEE TRAFFIC CONTROL NOTES THIS SHEET H 24" CURB AND GUTTER, SEE DETAILS CREEK CENTERLINE 17 R25'R25' R30' R30' R30' R25' R20' R20'R20' R20' R20' R20' R30' R15' R15' R15' R30' 18' 9' 24' 18' 9' 24' 9' 24'18' 24' 11 16 14 15 18 10 10 19 17 17 17 13 12 10 18 16 16 11 E E RIGHT OF WAY R38' A A A AB C C C C C A A 24' D GREGORY C IRC60' R IGHT OF WAY R15' 7 TOWNHOUSE BUILDING #1 6 UNITS TOWNHOUSE BUILDING #2 6 UNITS TOWNHOUSE BUILDING #3 7 UNITS TOWNHOUSE BUILDING #4 7 UNITSTOWNHOUSE BUILDING #56 UNITSTOWNHOUSE BUILDING #68 UNITSTOWNHOUSE BUILDING #78 UNITSTOWNHOUSE BUILDING #88 UNITSTOWNHOUSE BUILDING #98 UNITSTOWNHOUSE BUILDING #108 UNITS20' 20' 20' 20' 20' 20' GENERAL NOTES 1.ALL CONSTRUCTION SHALL CONFORM TO HARNETT COUNTY STANDARDS AND SPECIFICATIONS. 2.ROADS AND DRIVEWAYS SHALL COMPLY WITH NCDOT AND HARNETT COUNTY STANDARDS. 3.SIGN PERMITS SHALL BE REQUIRED FOR ANY ENTRANCE SIGNAGE. PERMITS SHALL BE REQUIRED PRIOR TO FABRICATION OR INSTALLATION OF SIGNS. SIGNAGE SHALL BE RESTRICTED TO AN ON-SITE LOCATION. 4.THE WATER AND SEWER SYSTEMS SHALL COMPLY WITH HARNETT COUNTY STANDARDS. 5.ALL DESIGN AND CONSTRUCTION METHODS SHALL COMPLY WITH WAKE COUNTY'S SEDIMENTATION AND EROSION CONTROL REGULATIONS. AN EROSION CONTROL PLAN SHALL BE APPROVED BY HARNETT COUNTY PRIOR TO ANY GRADING. 6.BOUNDARY INFORMATION TAKEN FROM A SURVEY BY BEN DEWAR, PLS. 7.TOPOGRAPHIC INFORMATION TAKEN BY BEN DEWAR, PLS. 8.PRIOR TO ISSUANCE OF A GRADING PERMIT, INSTALLATION AND INSPECTION BY HARNETT COUNTY OF TREE PROTECTION FENCING IS REQUIRED FOR LOTS ADJACENT TO TREE PRESERVATION AREAS. 9.CONSTRUCTION DRAWINGS SHALL BE SUBMITTED AND APPROVED BY HARNETT COUNTY PRIOR TO CONSTRUCTION. 10.A HOMEOWNER'S ASSOCIATION (HOA) WILL OWN AND MAINTAIN ALL OPEN SPACE PARCELS AND WILL BE RESPONSIBLE FOR MAINTAINING ALL LANDSCAPING REQUIRED BY HARNETT COUNTY UNITED DEVELOPMENT ORDINANCE (UDO). 11.STORMWATER CONTROL MEASURES SHALL BE CONTAINED IN AND ACCESSED VIA OPEN SPACE MAINTAINED AND OWNED BY THE HOMEOWNER'S ASSOCIATION. A MAINTENANCE PLAN MUST BE DEVELOPED TO ADDRESS THE STORMWATER CONTROL MEASURES. 12.PRIVATE STORM DRAINAGE EASEMENTS SHALL BE MAINTAINED BY THE OWNER. 13.PERMANENT AND TEMPORARY SIGNAGE REQUIRES AN APPROVED SIGN PERMIT PRIOR TO INSTALLATION. SIGNAGE IS A SEPARATE SUBMITTAL, REVIEW AND APPROVAL PROCESS BY THE PLANNING DEPARTMENT. 14.PRIOR TO RELEASE OF THE CERTIFICATE OF OCCUPANCY, THE OWNER/BUILDER MUST SUPPLY THE TOWN WITH A FINAL LETTER OF CERTIFICATION FROM LIGHTING ENGINEER, LIGHTING MANUFACTURE, OR AUTHORIZED LIGHTING CONTRACTOR VERIFYING THAT ALL SITE LIGHTING IS INSTALLED ACCORDING TO TOWN STANDARDS, THE APPROVED PLANS AND ANY APPLICABLE CONDITIONS. 15.THE TOWN WILL BE RESPONSIBLE FOR PAYMENT OF THE MONTHLY COSTS FOR LIGHTING AND THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL INITIAL FEES CHARGED WITH THE LIGHT INSTALLATION. ALL INSTALLATION FEES ARE REQUIRED TO BE PAID UP FRONT AT THE TIME OF INSTALLATION. 16.CONTACT THE ENGINEERING DEPARTMENT AT 910-893-7575 TO SCHEDULE A PRE-CONSTRUCTION MEETING PRIOR TO OBTAINING BUILDING PERMITS FOR THIS PLAN. 17.DURING THE ENTIRE PERIOD OF CONSTRUCTION ACTIVITY, ALL PROTECTED TREES SHALL BE SURROUNDED AND PROTECTED BY AN ORANGE TENSAR GEOGRID FENCING. TREE PROTECTION FENCING SHALL BE INSTALLED A MINIMUM OF 10' FROM TRUNK OF ANY PROTECTED TREE OR DRIP LINE. ONE SIGN SHALL BE PLACED EVERY 200' ALONG FENCING TO READ "TREE PROTECTION AREA - DO NOT ENTER / PARA PROTECCION DE LOS ARBOLES - PROHIBIDIO ENTRAR". 18.PERMANENT AND TEMPORARY SIGNAGE REQUIRES AN APPROVED SIGN PERMIT PRIOR TO INSTALLATION. SIGNAGE IS A SEPARATE SUBMITTAL, REVIEW, AND APPROVAL. F F FFF F F F F F F G G G G G G 24'18' 9' TRAFFIC CONTROL NOTES GENERAL NOTES: ·ALL WORK SHALL BE IN ACCORDANCE WITH HARNETT COUNTY AND/OR NCDOT STANDARD DETAILS AND SPECIFICATIONS. ·PRIOR TO THE START OF WORK, THE CLIENT SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITHNCDOT TO REVIEW THE SPECIFIC COMPONENTS OF THE APPROVED PLAN, AND ENSURE ALL PERMITS ARE ISSUED. ·MUST HAVE AN ISSUED RIGHT-OF-WAY PERMIT FOR STREET, LANE AND/OR SIDEWALK CLOSURE TO CONDUCT ANY WORK IN THE RIGHT-OF-WAY. ·ALL PERMITS MUST BE AVAILABLE ON-SITE DURING THE OPERATION. ·FIELD ADJUSTMENTS TO THE APPROVED PLAN MAY BE REQUIRED BY NCDOT AS NEEDED DURING CONSTRUCTION. ·ANY REVISION TO THE APPROVED PLAN MUST BE APPROVED BY NCDOT PRIOR TO IMPLEMENTATION. ·ANY DAMAGE TO THE RIGHT OF WAY SHALL BE REPAIRED PER NCDOT SPECIFICATIONS AT NO COST TO THECITY. ·ALL PAVEMENT MARKINGS SHALL BE RESTORED TO ORIGINAL PLACEMENT AND CONDITIONS. ·CONSTRUCTION FENCING SHOULD NOT ENCROACH INTO THE PUBLIC RIGHT OF WAY. IF IT DOES, IT MUST BEMOVABLE IN CASE ADJUSTMENTS HAVE TO BE MADE. NO DRILLING, BORING OR ANY PERMANENT FASTENING OF THE FENCE IS ALLOWED IN THE PUBLIC RIGHT OF WAY. ·NO PORTABLE RESTROOMS ARE PERMITTED IN THE PUBLIC RIGHT-OF-WAY. ACCESSIBLE RESTROOMS MUST BE PROVIDED ON SITE. ·ALL SIGNAGE MUST BE VERIFIED AND MAINTAINED PROPERLY BY CONTRACTOR BEFORE THE START OF WORK AND REMAIN INTACT FOR THE DURATION OF THE PROJECT. ·DRIVEWAYS IMPACTED BY THE LANE CLOSURE MUST REMAIN ACCESSIBLE ·WHEN WORK IS PERFORMED WITHIN A SCHOOL ZONE DURING SCHOOL OPERATIONAL HOURS, WORK MUST NOT IMPEDE WITHIN THE POSTED SCHOOL TRAFFIC TIMES. THE WORK BEING PERFORMED MUST BE REPORTED TO THE PRINCIPAL OF THE SCHOOL PRIOR TO COMMENCEMENT OF WORK. ·SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSTALLED PRIOR TO THE COMMENCEMENT OF THE PROJECT. SUCH MEASURES INCLUDE BUT ARE NOT LIMITED TO: SILT FENCE, INLET PROTECTION, AND CONSTRUCTION ENTRANCE. ·THE STORM WATER CONTROL DEVICES CANNOT INTERFERE WITH ANY ADA ACCESSIBLE PATH. ·ALL EXISTING UNDERGROUND UTILITIES SHALL BE LOCATED PRIOR TO BEGINNING ANY EXCAVATION OR UNDERGROUND CONSTRUCTION. ALL UNDERGROUND UTILITY LOCATES SHALL BE ORDERED NO LESS THAN 3 DAYS PRIOR AND NO MORE THAN 12 DAYS PRIOR TO THE BEGINNING OF SAID EXCAVATION OR UNDERGROUND CONSTRUCTION. ·CURB/SIDEWALK REMOVAL DEBRIS, PRE-MADE BUILDING PACKAGES, GRAVEL, SOD, ETC. SHALL NOT BE STOCKPILED WITHIN THE PUBLIC RIGHT-OF-WAY. ·IF WORK IS BEING PERFORMED 5' FROM BACK OF CURB NO LANE CLOSURE IS REQUIRED. SIGNAGE OF WORK AHEAD IS REQUIRED TO NOTIFY TRAFFIC AND PEDESTRIANS. ·IF WORK IS BEING PERFORMED 15' FROM THE EDGE OF PAVEMENT NO LANE CLOSURE. SIGNAGE OF WORK AHEAD IS REQUIRED TO NOTIFY TRAFFIC AND PEDESTRIANS. ·A MINIMUM TWO-WAY ACCESS OF 20' IS REQUIRED AT ALL TIMES FOR TRAFFIC, NOT INCLUDING THE CURB AND GUTTER AREAS. ·IF ANY OPERATOR/CONTRACTOR PARKS IN A RESIDENTIAL AREA FORCING THE HOMEOWNER/RESIDENT TO PARK ON THE OTHER SIDE OF THE ROAD, NARROWING TO 20' OR LESS, THE OPERATOR/CONTRACTOR IS LIABLE TO ENSURE A LANE CLOSURE PERMIT IS OBTAINED. ·SIGHT VISIBILITY MUST BE MAINTAINED AT ALL TIMES.35' SETBACK 15' SETBACK 15' SETBACK35' SETBACK H EDWARD HUMPHREY D.B. 2762 PG. 308 D.B. 618 PG. 590 EDWARD HUMPHREY D.B. 3750 PG. 598 D.B. 618 PG. 590JOYCE ANDREWS D.B. 2834 PG. 476 SUSETTE WINDSOR TRUST D.B. 3183 PG. 520 PROPOSED WET POND PROPOSED OPEN SPACE 1.80 ACRES IMPROVED OPEN SPACE AREA 0.14 ACRES PROPOSED OPEN SPACE 0.46 ACRES PROPOSED OPEN SPACE MH 1 MH 2 MH 3 MH 5 MH 6 MH 21 MH 22 MH 4 8''W8''W8''W8''W8''W8''W 6' 'W6''W6' 'W6' 'W6' 'W8''W8''W8''W 8''WS SSANS SA N SANSANSSSANSANS SANSANSANSANS SANS S SS S S S SSSANSA N SANSANSANSANSANSANSANSANSAN207.10' OF 8" SDR 35 PVC @ 2.00 %182.32' OF 8" SDR 35 PVC @ 1.45% 16 0 . 4 7 ' O F 8 " S D R 3 5 P V C @ 1 . 1 3 % 112.75' OF 8" SDR 35 PVC @ 3.78% 86.82' OF 8" SDR 35 PVC @ 2.00% 300.00' OF 8" SDR 35 PVC @ 2.90%8" SDR 21 PVC8" SDR 21 PVC8" SDR 21 PVC 8" SDR 21 PVC 6" SDR 21 PVC6" SDR 21 PVCTOWNHOUSE BUILDING #1 6 UNITS TOWNHOUSE BUILDING #2 6 UNITS TOWNHOUSE BUILDING #3 7 UNITS TOWNHOUSE BUILDING #4 7 UNITSTOWNHOUSE BUILDING #56 UNITSTOWNHOUSE BUILDING #68 UNITSTOWNHOUSE BUILDING #78 UNITSTOWNHOUSE BUILDING #88 UNITSTOWNHOUSE BUILDING #98 UNITSTOWNHOUSE BUILDING #108 UNITSSANITARY PIPE TABLE PIPE # 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11 -12 DIA 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" FROM - TO MH 1 - MH 2 MH 2 - MH 3 MH 3 - MH 4 MH 4 - MH 5 MH 5 - MH 6 MH 6 - MH 7 MH 7 - MH 8 MH 8 - MH 9 MH 9 - MH 10 MH 10 - MH 11 MH 11 - MH 12 UPSTREAM INVERT 197.08 190.22 188.21 185.36 181.02 179.08 167.88 156.22 152.46 152.12 151.67 DOWNSTREAM INVERT 192.82 188.41 185.56 181.22 179.28 170.38 156.42 152.66 152.32 151.87 151.55 SLOPE 3.78% 1.13% 1.45% 2.00% 2.00% 2.90% 3.79% 3.64% 0.51% 0.50% 0.50% LENGTH 112.75 LF 160.47 LF 182.32 LF 207.10 LF 86.82 LF 300.00 LF 302.06 LF 97.83 LF 27.67 LF 49.75 LF 24.62 LF DESCRIPTION 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8" DUCTILE IRON 8 inch PVC 8 inch PVC C3.0 UTILITY PLANJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C3.0-UTIL.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN SEWER SANITARY SEWER SANITARY MANHOLE SAN EXISTING WATER LINE PROPOSED WATER LINE WATER VALVE FIRE HYDRANT BLOWOFF ASSEMBLY LEGEND W S WATER W EXISTING SANITARY SEWERSAN 0 SCALE 1"=40' 80'40'NAD 83KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. WATER QUANTITY TABLE 6" WATERLINE 545 LF 8" WATERLINE 976 LF MATCHLINE - SEE SHEET C3.1 UTILITY KEYNOTES A 2" GANG METER, SEE DETAIL SHEET AND PLUMBING PLAN B CONNECT 8" WATER MAIN TO EXISTING 6" WATER MAIN C 8" X 6" REDUCER D 6" X 6" TAPPING SLEEVE E 8" X 8" TEE F 2" WATER SERVICE LINE G SANITARY SEWER SERVICE CLEANOUT (SHALL BE TRAFFIC BEARING WHERE PLACED OUTSIDE OF GRASSED AREAS), SEE DETAIL SHEET H 6" GATE VALVE I 6" SANITARY SEWER SERVICE @ 1.0% MIN. SLOPE, 3' MIN. COVER (TYP.) J EXTEND SERVICE TO WITHIN 5'-0" OF BUILDING WALL. REFER TO PLUMBING PLANS FOR EXACT LOCATION AND INVERT ELEVATION K FIRE HYDRANT ASSEMBLY, SEE DETAIL SHEET RIGHT OF WAY CREEK CENTERLINE B C A K K H H D EXISTING FIRE HYDRANT EG A A A A A A A A A J J J J J J J I I I I I I I I F F F F F F F F F F J GREGORY C IRC60' R IGHT OF WAY 20' PUBLIC UTILITY EASEMENT PRIVATE STORMWATER EASEMENTS ARE SUBJECT TO CHANGE WITH CONSTRUCTION PLAN REVIEW. GENERAL CONTRACTOR: PRIOR TO BEGINNING ANY CONSTRUCTION, FIELD SURVEY VERIFYING LOCATION, DEPTH, TYPE, MATERIAL AND CONDITION OF ALL EXISTING UTILITIES. IN CASE OF CONFLICT, NOTIFY ENGINEER. 20' PUBLIC UTILITY EASEMENT 30' PUBLIC UTILITY EASEMENT 20' PUBLIC UTILITY EASEMENT C C UTILITY NOTES 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE HARNETT COUNTY STANDARDS AND SPECIFICATIONS. 2.MINIMUM UTILITY HORIZONTAL SEPARATION DISTANCES: WATER AND SANITARY SEWER MAINS - 10 FT. WATER AND STORM SEWER MAINS - 5 FT. SANITARY SEWER AND STORM SEWER MAINS - 5 FT. GRAVITY SANITARY SEWER AND FORCE MAINS - 5 FT. 3.MINIMUM UTILITY VERTICAL SEPARATION DISTANCES: WATER AND SANITARY SEWER MAINS - 24 IN. WATER AND STORM SEWER MAINS - 24 IN. SANITARY SEWER AND STORM SEWER MAINS - 24 IN. 1.INSTALL WATERMAINS WITH A COVER OF NO LESS THAN 3-FT. INSTALL WATER SERVICES WITH NO LESS THAN 18-IN OF COVER TO SUBGRADE. 2.INSTALL SEWER MAINS WITH A COVER OF NO LESS THAN 3-FT TO FINISHED GRADE UNLESS DUCTILE IRON PIPE IS USED. INSTALL SEWER SERVICES WITH NO LESS THAN 24-IN OF COVER TO SUBGRADE. 3.INSTALL ALL UTILITIES TO PROVIDE REQUIRED CLEARANCES AS INDICATED IN THE SPECIFICATIONS. 4.WATERLINES AND SEWER MAINS SHALL BE INSTALLED WITH A MINIMUM HORIZONTAL CLEARANCE OF 10-FT. 5.WATER AND SEWER MAINS SHALL BE INSTALLED WITH A MINIMUM VERTICAL CLEARANCE OF 24-IN TO STORM DRAINAGE PIPES. 6.COORDINATE AND SCHEDULE INSTALLATION OF ALL UTILITIES WITH OTHER PRIME CONTRACTORS, UTILITY COMPANIES AND OTHER TRADES INCLUDING BUT NOT LIMITED TO: NATURAL GAS, ELECTRICITY, TELEPHONE AND CATV. 7.VERIFY EXISTING CONDITIONS AND CONNECTIONS TO EXISTING UTILITIES PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE DISCOVERED. 8.CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER. 9.ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE NCSBC AND OSHA REQUIREMENTS. 10.THE CONTRACTOR SHALL PROVIDE AN AS-BUILT SURVEY OF ALL UTILITY AND STORM DRAINAGE IMPROVEMENTS FOLLOWING CONSTRUCTION. 11.CONTRACTOR SHALL PHASE DEMOLITION AND NEW CONSTRUCTION TO ENSURE UNINTERRUPTED ACCESS AND UTILITY SERVICE TO ADJACENT FACILITIES. 12.SEE GENERAL NOTES ON EXISTING CONDITIONS AND DEMOLITION PLAN FOR REQUIREMENTS FOR REMOVAL AND PATCHING OF PAVEMENT FOR UTILITY INSTALLATION. 13.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL LOCAL JURISDICTION STANDARDS AND SPECIFICATIONS. 14.ALL SANITARY SEWER SERVICES SHALL BE 6" PVC (SCH 40) @ 1.04% MIN. SLOPE UNLESS INDICATED OTHERWISE. USE DUCTILE IRON WHEN COVER IS LESS THAN 24-IN. 15.SEWER IS TO BE OWNED AND MAINTAINED BY THE HARNETT COUNTY. 16.CONTRACTOR TO PROVIDE TESTING FOR FILL ON SEWER LINE. 17.CONTRACTOR TO SOFT DIG FOR RAW WATER LINE LOCATIONS. 18.CONTRACTOR WILL NEED TO HAVE A PRE-CONSTRUCTION MEETING WITH THE HARNETT COUNTY STAFF PRIOR TO RELEASE OF APPROVED PERMITTED PLANS. 19.HARNETT COUNTY REPRESENTATIVE WILL NEED TO BE AT THE PRE-CON MEETING FOR THE UTILITIES. PROPOSED WET POND 30' PUBLIC UTILITY EASEMENT182.33' OF 8" SDR 35 PVC @3.10%178.63' OF 8" SDR 35 PVC @2.56% MH 7 MH 8SSSANSANSANSANSAN S SSSSSA NSSSANSANSANSANSAN302.06' OF 8" SDR 35 PVC @ 3.79%SS SSSSA N 97.83' OF 8" SDR 35 PVC @ 3.64% 27.67' OF 8" Ductile Iron @ 0.51% 49.75' OF 8" SDR 35 PVC @ 0.50% 24.62' OF 8" SDR 35 PVC @ 0.50% 10.00' OF 8" SDR 35 PVC @ 0.50% MH 9 MH 10 MH 11 MH 12 EX1 SANITARY PIPE TABLE PIPE # 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11 -12 DIA 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" FROM - TO MH 1 - MH 2 MH 2 - MH 3 MH 3 - MH 4 MH 4 - MH 5 MH 5 - MH 6 MH 6 - MH 7 MH 7 - MH 8 MH 8 - MH 9 MH 9 - MH 10 MH 10 - MH 11 MH 11 - MH 12 UPSTREAM INVERT 197.08 190.22 188.21 185.36 181.02 179.08 167.88 156.22 152.46 152.12 151.67 DOWNSTREAM INVERT 192.82 188.41 185.56 181.22 179.28 170.38 156.42 152.66 152.32 151.87 151.55 SLOPE 3.78% 1.13% 1.45% 2.00% 2.00% 2.90% 3.79% 3.64% 0.51% 0.50% 0.50% LENGTH 112.75 LF 160.47 LF 182.32 LF 207.10 LF 86.82 LF 300.00 LF 302.06 LF 97.83 LF 27.67 LF 49.75 LF 24.62 LF DESCRIPTION 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8 inch PVC 8" DUCTILE IRON 8 inch PVC 8 inch PVC C3.1 UTILITY PLANJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C3.0-UTIL.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN 0 SCALE 1"=40' 80'40'NAD 83KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. MATCHLINE CREEK CENTERLINE EXISTING PUMP STATION SEWER SANITARY SEWER SANITARY MANHOLE SAN EXISTING WATER LINE PROPOSED WATER LINE WATER VALVE FIRE HYDRANT BLOWOFF ASSEMBLY LEGEND W S WATER W EXISTING SANITARY SEWERSAN RIGHT OF WAY UTILITY KEYNOTES A 2" GANG METER, SEE DETAIL SHEET AND PLUMBING PLAN B CONNECT 8" WATER MAIN TO EXISTING 6" WATER MAIN C 8" X 6" REDUCER D 6" X 6" TAPPING SLEEVE E 8" X 8" TEE F 2" WATER SERVICE LINE G SANITARY SEWER SERVICE CLEANOUT (SHALL BE TRAFFIC BEARING WHERE PLACED OUTSIDE OF GRASSED AREAS), SEE DETAIL SHEET H 6" GATE VALVE I 6" SANITARY SEWER SERVICE @ 1.0% MIN. SLOPE, 3' MIN. COVER (TYP.) J EXTEND SERVICE TO WITHIN 5'-0" OF BUILDING WALL. REFER TO PLUMBING PLANS FOR EXACT LOCATION AND INVERT ELEVATION K FIRE HYDRANT ASSEMBLY, SEE DETAIL SHEET WATER QUANTITY TABLE 6" WATERLINE 545 LF 8" WATERLINE 976 LF PRIVATE STORMWATER EASEMENTS ARE SUBJECT TO CHANGE WITH CONSTRUCTION PLAN REVIEW. GENERAL CONTRACTOR: PRIOR TO BEGINNING ANY CONSTRUCTION, FIELD SURVEY VERIFYING LOCATION, DEPTH, TYPE, MATERIAL AND CONDITION OF ALL EXISTING UTILITIES. IN CASE OF CONFLICT, NOTIFY ENGINEER. 20' PUBLIC UTILITY EASEMENT UTILITY NOTES 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE HARNETT COUNTY STANDARDS AND SPECIFICATIONS. 2.MINIMUM UTILITY HORIZONTAL SEPARATION DISTANCES: WATER AND SANITARY SEWER MAINS - 10 FT. WATER AND STORM SEWER MAINS - 5 FT. SANITARY SEWER AND STORM SEWER MAINS - 5 FT. GRAVITY SANITARY SEWER AND FORCE MAINS - 5 FT. 3.MINIMUM UTILITY VERTICAL SEPARATION DISTANCES: WATER AND SANITARY SEWER MAINS - 24 IN. WATER AND STORM SEWER MAINS - 24 IN. SANITARY SEWER AND STORM SEWER MAINS - 24 IN. 1.INSTALL WATERMAINS WITH A COVER OF NO LESS THAN 3-FT. INSTALL WATER SERVICES WITH NO LESS THAN 18-IN OF COVER TO SUBGRADE. 2.INSTALL SEWER MAINS WITH A COVER OF NO LESS THAN 3-FT TO FINISHED GRADE UNLESS DUCTILE IRON PIPE IS USED. INSTALL SEWER SERVICES WITH NO LESS THAN 24-IN OF COVER TO SUBGRADE. 3.INSTALL ALL UTILITIES TO PROVIDE REQUIRED CLEARANCES AS INDICATED IN THE SPECIFICATIONS. 4.WATERLINES AND SEWER MAINS SHALL BE INSTALLED WITH A MINIMUM HORIZONTAL CLEARANCE OF 10-FT. 5.WATER AND SEWER MAINS SHALL BE INSTALLED WITH A MINIMUM VERTICAL CLEARANCE OF 24-IN TO STORM DRAINAGE PIPES. 6.COORDINATE AND SCHEDULE INSTALLATION OF ALL UTILITIES WITH OTHER PRIME CONTRACTORS, UTILITY COMPANIES AND OTHER TRADES INCLUDING BUT NOT LIMITED TO: NATURAL GAS, ELECTRICITY, TELEPHONE AND CATV. 7.VERIFY EXISTING CONDITIONS AND CONNECTIONS TO EXISTING UTILITIES PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE DISCOVERED. 8.CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER. 9.ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE NCSBC AND OSHA REQUIREMENTS. 10.THE CONTRACTOR SHALL PROVIDE AN AS-BUILT SURVEY OF ALL UTILITY AND STORM DRAINAGE IMPROVEMENTS FOLLOWING CONSTRUCTION. 11.CONTRACTOR SHALL PHASE DEMOLITION AND NEW CONSTRUCTION TO ENSURE UNINTERRUPTED ACCESS AND UTILITY SERVICE TO ADJACENT FACILITIES. 12.SEE GENERAL NOTES ON EXISTING CONDITIONS AND DEMOLITION PLAN FOR REQUIREMENTS FOR REMOVAL AND PATCHING OF PAVEMENT FOR UTILITY INSTALLATION. 13.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL LOCAL JURISDICTION STANDARDS AND SPECIFICATIONS. 14.ALL SANITARY SEWER SERVICES SHALL BE 6" PVC (SCH 40) @ 1.04% MIN. SLOPE UNLESS INDICATED OTHERWISE. USE DUCTILE IRON WHEN COVER IS LESS THAN 24-IN. 15.SEWER IS TO BE OWNED AND MAINTAINED BY THE HARNETT COUNTY. 16.CONTRACTOR TO PROVIDE TESTING FOR FILL ON SEWER LINE. 17.CONTRACTOR TO SOFT DIG FOR RAW WATER LINE LOCATIONS. 18.CONTRACTOR WILL NEED TO HAVE A PRE-CONSTRUCTION MEETING WITH THE HARNETT COUNTY STAFF PRIOR TO RELEASE OF APPROVED PERMITTED PLANS. 19.HARNETT COUNTY REPRESENTATIVE WILL NEED TO BE AT THE PRE-CON MEETING FOR THE UTILITIES. CONTRACTOR SHALL TIE TO EXISTING PUMP STATION. CONTRACTOR SHALL COMPLY WITH ALL STATE GUIDLINES AND STANDARDS. APPROXIMATE LOCATION OF EXISTING SANITARY SEWER EASEMENT STORM PIPE TABLE PIPE # 101-100 102-101 103-102 104-103 105-104 105A-105 106-105 110-102 111-110 112-111 113-112 DIA 24" 24" 24" 18" 15" 15" 15" 18" 15" 15" 15" FROM - TO CB 101 - FES 100 CB 102 - CB 101 CB 103 - CB 102 CB 104 - CB 103 CB 105 - CB 104 CB 105A - CB 105 CB 106 - CB 105 CB 110 - CB 102 CB 111 - CB 110 CB 112 - CB 111 CB 113 - CB 112 UPSTREAM INVERT 185.05 187.51 188.41 189.75 192.45 195.95 193.64 188.12 192.24 195.54 196.55 DOWNSTREAM INVERT 179.00 186.55 187.51 188.91 190.00 193.45 192.45 188.01 188.37 192.24 195.54 SLOPE 6.59% 0.99% 1.00% 0.99% 1.01% 4.96% 1.00% 1.08% 3.08% 1.43% 2.61% LENGTH 91.84 LF 96.64 LF 90.41 LF 84.48 LF 243.24 LF 50.41 LF 119.19 LF 10.19 LF 125.67 LF 230.22 LF 38.71 LF DESCRIPTION 24 inch RCP 24 inch RCP 24 inch RCP 18 inch RCP 15 inch RCP 15 inch RCP 15 inch RCP 18 inch RCP 15 inch RCP 15 inch RCP 15 inch RCP STORM PIPE TABLE PIPE # CULVERT 1 CULVERT 2 DIA 18" 18" FROM - TO - - UPSTREAM INVERT 197.00 181.00 DOWNSTREAM INVERT 193.00 175.00 SLOPE 4.79% 13.77% LENGTH 83.42 LF 43.58 LF DESCRIPTION 18 inch RCP 18 inch RCP 8''W8''W8''W8''W8''W8''W 6' 'W6''W6' 'W6' 'W6' 'W8''W8''W8''W 8''WS SSANS SA N SANSANSSSANSANS SANSANSANSANS SANS 7 14 11 17 22 17 23 19 17 10 15 18 18 16 11 17 16 16 1 9 0 195200 204 2 0 3 202 20 1 1 9 9 1 9 8 196 194 193 192 1911 8 9 188187185190 180 175 170 165 175185190195172203202201200 2 0 2 2 0 1 2 0 0 204 200197194195192190195190178 1 9 6 1 9 7 198 197196200 199 198 183178187178189185CB 113 CB 105A CB 112 CB 105 CB 106 CB 104 CB 111 CB 103 CB 101 CB 110 CB 102 FES 100 15 " RCP15" RCP18" RCP24" RCP24" RCP15" R C P 15" RCP15" RCP15" R C P 24" RCP193191 188 185 182 195 193 198195191190195193177 180 183 185 174 199200202 202 1 9 7198 197198199 19519719819920 0 198 2 0 3 204 191195198180185 19019519318818319919719818" RCP18" RCP178 182185187185180175170182FFE=200 . 9 6 ' FFE=200 . 6 3 ' FFE=200 . 6 3 ' FFE=200. 3 0 ' FFE=199. 9 7 ' FFE=199. 6 4 ' FFE=199. 4 7 ' FFE=199. 1 4 ' FFE=199 . 1 4 ' FFE=198. 8 1' FFE=198. 8 1 ' FFE=198. 4 8 ' FFE=198. 1 5 ' FFE=198. 1 5 ' FFE=197 . 8 1 ' FFE=197 . 4 8 ' FFE=197.1 5 ' FFE=197. 1 5 ' FFE=196 . 8 2 ' FFE=196 . 4 9 ' FFE=196.4 9 ' FFE=196. 1 6 'FFE=202.51'FFE=202.84'FFE=203.34'FFE=203.67'FFE=204.00'FFE=204.50'FFE=204.61'FFE=204.28'FFE=203.78'FFE=203.28'FFE=202.95'FF E = 2 0 0 . 4 9 ' FF E = 2 0 0 . 1 6 ' FF E = 1 9 9 . 8 3 ' FF E = 1 9 9 . 8 3 ' FF E = 1 9 9 . 5 0 ' FF E = 1 9 9 . 5 0 ' FF E = 1 9 9 . 1 7 ' FF E = 1 9 9 . 1 7 ' FF E = 1 9 8 . 8 9 ' FF E = 1 9 8 . 8 9 ' FF E = 1 9 8 . 5 6 ' FF E = 1 9 8 . 5 6 ' FF E = 1 9 8 . 2 3 ' FF E = 1 9 7 . 9 0 ' FF E = 1 9 7 . 9 0 ' FF E = 1 9 7 . 5 7 ' FF E = 1 9 7 . 4 8 ' FF E = 1 9 7 . 1 5 ' FF E = 1 9 7 . 1 5 ' FF E = 1 9 6 . 8 2 ' FF E = 1 9 6 . 8 2 ' FF E = 1 9 6 . 4 9 ' FF E = 1 9 6 . 4 9 ' FF E = 1 9 6 . 1 6 'FFE=201.01'FFE=201.34'FFE=201.67'FFE=202.17'FFE=202.50'FFE=203.00'FFE=203.33'FFE=203.38'FFE=202.88'FFE=202.55'FFE=202.05'FFE=201.55'FFE=201.22'FFE=200.72'FFE=202.45'18" RCP TOWNHOUSE BUILDING #1 6 UNITS TOWNHOUSE BUILDING #2 6 UNITS TOWNHOUSE BUILDING #3 7 UNITS TOWNHOUSE BUILDING #4 7 UNITSTOWNHOUSE BUILDING #56 UNITSTOWNHOUSE BUILDING #68 UNITSTOWNHOUSE BUILDING #78 UNITSTOWNHOUSE BUILDING #88 UNITSTOWNHOUSE BUILDING #98 UNITSTOWNHOUSE BUILDING #108 UNITSLOD LODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODL O D LODLODLO DLODLOD C4.0 GRADING PLANJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C4.0-GRAD.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN 0 SCALE 1"=40' 80'40'NAD 83KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. GENERAL NOTES 1.TOTAL DISTURBED AREA = 7.89 AC 2.ALL EXISTING VAULTS, MANHOLES, STORM DRAIN STRUCTURES, VALVE BOXES, CLEANOUTS, ETC. SHALL BE ADJUSTED AS NEEDED TO MATCH FINISHED GRADES. 3.ALL BACKFILL, COMPACTION, SOILS TESTING, ETC. SHALL BE PERFORMED BY THE OWNER'S INDEPENDENT TESTING LABORATORY. 4.ALL SPOT ELEVATIONS INDICATED ARE AT BACK OF CURB, UNLESS OTHERWISE INDICATED. 5.SITE IS NOT WITHIN 100 YEAR FLOOD PLAIN. 6.ALL ELEVATIONS ARE BASED ON NC GRID NORTH (NAD 83). 7.A PRECONSTRUCTION MEETING MUST BE SCHEDULED PRIOR TO WORK, GRADING AND INSTALLATION OF EROSION CONTROL. 8.UTILITY LOCATIONS ARE TO BE FOUND BY CALLING NC ONE CALL. 9.ALL HANDICAP PARKING SPACES AND STRIPED ACCESSIBILITY AISLES ARE TO HAVE NO MORE THAN A 1:50 SLOPE IN ALL DIRECTIONS. 10.ALL SIDEWALKS ARE TO HAVE NO MORE THAN A 1:20 SLOPE FOR THE LENGTH OF THE SIDEWALK AND NO MORE THAN A 1:50 SLOPE FOR THE WIDTH OF THE SIDEWALK. 11.IF CONTRACTOR NOTICES ANY DISCREPANCIES IN ANY OF THESE SLOPE REQUIREMENTS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNER PRIOR TO POURING ANY CONCRETE SO THAT A SOLUTION CAN BE FOUND. 12.CONTACT THE HARNETT COUNTY ENGINEERING DEPARTMENT PRIOR TO CONVERSION OF ANY SCM ONSITE FROM AN EROSION CONTROL DEVICE TO A STORMWATER CONTROL MEASURE. 13.ALL SLOPES TO BE VEGETATED WITH GRASS SHALL BE A MAXIMUM OF 3:1. 14.ALL ROOF DRAINS SHALL BE DIRECTED TO THE STORM DRAIN SYSTEM. 15.AT THE CONCLUSION OF THE PROJECT ALL SCMS INSTALLED ON-SITE MUST BE CERTIFIED BY A DESIGN PROFESSIONAL AND THE HARNETT COUNTY ENGINEERING DEPARTMENT MUST RECEIVE ALL AS BUILT DRAWINGS PRIOR TO RECEIVING THE CERTIFICATE OF OCCUPANCY. LEGEND PROPERTY LINE TREE PROTECTION FENCE BUILDING SETBACK ACCESS EASEMENT SANITARY SEWER EASEMENT 100 YEAR FLOODPLAIN RIGHT OF WAY LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE REFER TO POND PROFILE SHEET C8.0 CREEK CENTERLINE MATCHLINE - SEE SHEET C4.1 GREGORY C IRC60' R IGHT OF WAY PROPOSED WET POND STORM PIPE TABLE PIPE # 101-100 102-101 103-102 104-103 105-104 105A-105 106-105 110-102 111-110 112-111 113-112 DIA 24" 24" 24" 18" 15" 15" 15" 18" 15" 15" 15" FROM - TO CB 101 - FES 100 CB 102 - CB 101 CB 103 - CB 102 CB 104 - CB 103 CB 105 - CB 104 CB 105A - CB 105 CB 106 - CB 105 CB 110 - CB 102 CB 111 - CB 110 CB 112 - CB 111 CB 113 - CB 112 UPSTREAM INVERT 185.05 187.51 188.41 189.75 192.45 195.95 193.64 188.12 192.24 195.54 196.55 DOWNSTREAM INVERT 179.00 186.55 187.51 188.91 190.00 193.45 192.45 188.01 188.37 192.24 195.54 SLOPE 6.59% 0.99% 1.00% 0.99% 1.01% 4.96% 1.00% 1.08% 3.08% 1.43% 2.61% LENGTH 91.84 LF 96.64 LF 90.41 LF 84.48 LF 243.24 LF 50.41 LF 119.19 LF 10.19 LF 125.67 LF 230.22 LF 38.71 LF DESCRIPTION 24 inch RCP 24 inch RCP 24 inch RCP 18 inch RCP 15 inch RCP 15 inch RCP 15 inch RCP 18 inch RCP 15 inch RCP 15 inch RCP 15 inch RCP STORM PIPE TABLE PIPE # CULVERT 1 CULVERT 2 DIA 18" 18" FROM - TO - - UPSTREAM INVERT 197.00 181.00 DOWNSTREAM INVERT 193.00 175.00 SLOPE 4.79% 13.77% LENGTH 83.42 LF 43.58 LF DESCRIPTION 18 inch RCP 18 inch RCP SSSANSANSANSANSAN S SSSSSA N187 165 161 160 160161165170175180 185 FES 200 2 4 " RCP185180175170165161160187187183178179185182187185180175170LODLODLODLODLODLODLO D LO D LOD L O D LO DLODLODLODLODLODL O D LOD LODC4.1 GRADING PLANJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C4.0-GRAD.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN 0 SCALE 1"=40' 80'40'NAD 83KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. GENERAL NOTES 1.TOTAL DISTURBED AREA = 7.89 AC 2.ALL EXISTING VAULTS, MANHOLES, STORM DRAIN STRUCTURES, VALVE BOXES, CLEANOUTS, ETC. SHALL BE ADJUSTED AS NEEDED TO MATCH FINISHED GRADES. 3.ALL BACKFILL, COMPACTION, SOILS TESTING, ETC. SHALL BE PERFORMED BY THE OWNER'S INDEPENDENT TESTING LABORATORY. 4.ALL SPOT ELEVATIONS INDICATED ARE AT BACK OF CURB, UNLESS OTHERWISE INDICATED. 5.SITE IS NOT WITHIN 100 YEAR FLOOD PLAIN. 6.ALL ELEVATIONS ARE BASED ON NC GRID NORTH (NAD 83). 7.A PRECONSTRUCTION MEETING MUST BE SCHEDULED PRIOR TO WORK, GRADING AND INSTALLATION OF EROSION CONTROL. 8.UTILITY LOCATIONS ARE TO BE FOUND BY CALLING NC ONE CALL. 9.ALL HANDICAP PARKING SPACES AND STRIPED ACCESSIBILITY AISLES ARE TO HAVE NO MORE THAN A 1:50 SLOPE IN ALL DIRECTIONS. 10.ALL SIDEWALKS ARE TO HAVE NO MORE THAN A 1:20 SLOPE FOR THE LENGTH OF THE SIDEWALK AND NO MORE THAN A 1:50 SLOPE FOR THE WIDTH OF THE SIDEWALK. 11.IF CONTRACTOR NOTICES ANY DISCREPANCIES IN ANY OF THESE SLOPE REQUIREMENTS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNER PRIOR TO POURING ANY CONCRETE SO THAT A SOLUTION CAN BE FOUND. 12.CONTACT THE HARNETT COUNTY ENGINEERING DEPARTMENT PRIOR TO CONVERSION OF ANY SCM ONSITE FROM AN EROSION CONTROL DEVICE TO A STORMWATER CONTROL MEASURE. 13.ALL SLOPES TO BE VEGETATED WITH GRASS SHALL BE A MAXIMUM OF 3:1. 14.ALL ROOF DRAINS SHALL BE DIRECTED TO THE STORM DRAIN SYSTEM. 15.AT THE CONCLUSION OF THE PROJECT ALL SCMS INSTALLED ON-SITE MUST BE CERTIFIED BY A DESIGN PROFESSIONAL AND THE HARNETT COUNTY ENGINEERING DEPARTMENT MUST RECEIVE ALL AS BUILT DRAWINGS PRIOR TO RECEIVING THE CERTIFICATE OF OCCUPANCY. LEGEND PROPERTY LINE TREE PROTECTION FENCE BUILDING SETBACK ACCESS EASEMENT SANITARY SEWER EASEMENT 100 YEAR FLOODPLAIN MATCHLINE RISER TOP: 186.00 INV OUT: 181.00 BOTTOM: 177.00 SEE POND SHEET FOR ORIFICE INFORMATION 6'W X 18'L X 18"T CLASS A RIPRAP SS SSSSSSANSANSAN SANSAN MH 1 MH 2 MH 21 MH 3 MH 22 MH 4 MH 5 8" SDR 35 PVC 8" SDR 35 PVC8" S D R 3 5 P V C 8" SDR 35 P V C 8" S D R 3 5 P V C 8" SDR 3 5 P V C CB 113 CB 105A CB 112 CB 104 CB 111 CB 103 CB 101 CB 110 CB 102 15" R C P 15 " R C P 18 " R C P 24 " R C P 24 " R C P 15" RCP 15" RCP 15" RCP 18" RCP 0+00 1+00 2+003+ 0 0 4+ 0 0 5+ 0 0 6+ 0 08''W8''W8''W8''W6''W 6''W 6''W 6''W8''W8''W8''W197 19 8 2 0 0 2 0 1 2 0 2 2 0 3 202203 202201200199197196197196197 198 19818 1 19018 5 18 0 2002042 0 0 2 0 0 1 9 5 TOWNHOUSE BUILDING #16 UNITSTOWNHOUSE BUILDING #26 UNITSTOWNHOUSE BUILDING #37 UNITSTOWNHOUSE BUILDING #47 UNITSTOWNHOU S E B U I L D I N G # 7 8 UNITSTOWNHOUSE BUILDING #98 UNITSTOWNHOUSE BUILDING #108 UNITS175 180 185 190 195 200 205 210 215 220 225 SANITARY SEWER OUTFALL - MH 1 TO PUMP STATION PROFILE203.78203.37203.05200.38198.03197.61197.54197.12196.73196.34195.89195.46195.32195.47MH 1 TOP 203.78 INV OUT 197.08 (TO MH 2) MH 2 TOP 202.39 INV IN 192.82 (FR MH 1) INV OUT 190.22 (TO MH 3) 113 L F8" S D R 3 5 P V C @ 3. 7 8 % 160 LF 8" SDR 35 PVC @ 1.13% MH 3 TOP 197.69 INV IN 188.41 (FR MH 2) INV OUT 188.21 (TO MH 4) 182 LF 8" SDR 35 P V C @ 1.45% MH 4 TOP 196.31 INV IN 185.56 (FR MH 3) INV OUT 185.36 (TO MH 5) 207 LF 8" SDR 3 5 P V C @ 2.00% MH 5 TOP 195.54 INV IN 181.22 (FR MH 22) INV IN 181.22 (FR MH 4) INV OUT 181.02 (TO MH 6) 24" MIN 15" RCP EXISTING GRADE FINISHED GRADE 3' MIN 3' MIN 8" PVC WATER 8" PVC WATER SCALE 1"=50' 100'50'0 C5.0 UTILITY PROFILESNAD 83JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C5.0-UTPR.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. PROFILE SCALE 0 0 50 5 SANITARY SEWER OUTFALL A - PROFILE STA 0+00 TO STA 7+10 S A N I T A R Y S E W E R O U T F A L L ASANITARY SEWER OUTFALL A20' PUBLIC UTILITY EASEMENT 30' PUBLIC UTILITY EASEMENT SSS SSAN SAN SAN SAN MH 6 MH 7 MH 88" SDR 35 PVC8" SDR 35 PVC 8" SDR 35 PVC FES 100 24" RCP 15+61.397+008+00 9+00 10+00 11+00 12+00 13+00 14+0015+001961921831 7 8 1 7 9 1 7 8 1 7 9 182 187 187161 187 187 1 8 8 1 9 5 160 16517 0175180185 190TOWNHOUSE BUILDING #10SSSSS8" SDR 35 P V C MH 9 MH 10 8" Ductile Iron 8" SDR 35 PVC 8" SDR 35 PVC MH 11 MH 12 8" SDR 35 PVC EX1 145 150 155 160 165 170 175 180 185 190 195 145 150 155 160 165 170 175 180 185 190 195 SANITARY SEWER OUTFALL - MH 1 TO PUMP STATION PROFILE194.5087 LF 8" SDR 35 PVC @ 2.00% MH 6 TOP 192.12 INV IN 179.28 (FR MH 5) INV OUT 179.08 (TO MH 7) 300 LF8" SD R 3 5 P V C @ 2.9 0 % MH 7 TOP 183.40 INV IN 170.38 (FR MH 6) INV OUT 167.88 (TO MH 8) 302 L F8" S D R 3 5 P V C @ 3. 7 9 % MH 8 TOP 164.78 INV IN 156.42 (FR MH 7) INV OUT 156.22 (TO MH 9) 24" MIN 24" RCP EXISTING GRADE 3' MIN EXISTING CREEK BED FINISHED GRADE 10" 98 L F8" S D R 3 5 P V C @ 3. 6 4 % MH 9 TOP 158.10 INV IN 152.66 (FR MH 8) INV OUT 152.46 (TO MH 10) MH 10 TOP 158.15 INV IN 152.32 (FR MH 9) INV OUT 152.12 (TO MH 11) 50 LF 8" SDR 35 PVC @ 0.50% MH 11 TOP 163.71 INV IN 151.87 (FR MH 10) INV OUT 151.67 (TO MH 12) 25 LF 8" SDR 35 PVC @ 0.50% MH 12 TOP 164.22 INV IN 151.55 (FR MH 11) INV OUT 151.35 (TO EX1) EX1 TOP 162.42 INV IN 151.30 (FR MH 12) 10 LF 8" SDR 35 PVC @ 0.50% 28 LF 8" Ductile Iron @ 0.51% C5.1 UTILITY PROFILESJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C5.0-UTPR.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. SCALE 1"=50' 100'50'0 NAD 83PROFILE SCALE 0 0 50 5 SANITARY SEWER OUTFALL A - PROFILE STA 7+10 TO STA 15+03.71 EXISTING PUMP STATIONPROPOSED WET POND SANITARY SEWER OUTFALL A APPROXIMATE LOCATION OF EXISTING SANITARY SEWER EASEMENT 20' PUBLIC UTILITY EASEMENT SSSSSSANSAN SAN SANMH 21 MH 22 MH 5 MH 6 MH 78" SDR 35 PVC8" SDR 35 PVC 8" SDR 35 PVC 8" SDR 35 PVC CB 113 CB 112 CB 111 CB 101 CB 110 CB 102 FES 100 2 4 " R C P15" RCP15" RCP 15" RCP 18" RCP 24" RCP 3+60.97 0+00 1+00 2+00 3+00 6''W 6''W 6''W 6''W199196 196197 1921831 7 8 1 7 9 1 7 8 1 7 9 182 187 187 161 187 187 16517 0175180185 190 TOWNHOUSE BUILDING #5 6 UNITS TOWNHOUSE BUILDING #6 8 UNITS TOWNHOUSE BUILDING #7 8 UNITS HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 SANITARY SEWER OUTFALL B - PROFILE 170 175 180 185 190 195 200 205 210 170 175 180 185 190 195 200 205 210 24" MIN 24" RCP EXISTING GRADE FINISHED GRADE 196.8196.2195.7195.0194.5194.1193.6193.0198.31197.90197.52197.14196.74196.37196.00195.63-1+00 0+00 1+00 2+00 3+00 4+00 MH 21 TOP 198.31 INV OUT 191.23 (TO MH 22) 182 L F8" SD R 3 5 P V C @ 3.1 0 % MH 22 TOP 196.84 INV IN 185.59 (FR MH 21) INV OUT 185.79 (TO MH 5) MH 5 TOP 195.54 INV IN 181.22 (FR MH 22) INV IN 181.22 (FR MH 4) INV OUT 181.02 (TO MH 6) 179 LF 8" SD R 3 5 P V C @ 2.56 % C5.2 UTILITY PROFILESJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C5.0-UTPR.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. SCALE 1"=50' 100'50'0 NAD 83PROFILE SCALE 0 0 50 5 SANITARY SEWER OUTFALL B 30' PUBLIC UTILITY EASEMENT 20' PUBLIC UTILITY EASEMENT C6.0 NOTES AND DETAILSJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C7.0-NTDT.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN C6.1 NOTES AND DETAILSJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C7.0-NTDT.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN STANDARD GANG METER DETAIL C6.2 NOTES AND DETAILSJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C7.0-NTDT.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN ACCESSIBLE PARKING SIGNAGE NOT TO SCALE NOTE: MAXIMUM PENALTY SHALL BE PER LATEST FINE AMOUNT AS SPECIFIED BY LOCAL AUTHORITIES. ACCESSIBLE VAN ACCESSIBLE SIGN R7-8D SIGN R7-8 OR GALV. STL. POST FINISHED GRADE 3' DEEP CONC "VAN ACCESSIBLE" BOTTOM OF SIGNS R7-8 OR R7-8A 60" FOOTING R7-8A SIGN AND REQUIREMENTS. ACCORDANCE WITH LATEST MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, NCSBC AND ADA SPECIFICATIONS ALL SIGNS SHALL BE PROVIDED AND INSTALLED IN R7-8A RESERVED PARKING R7-8D $250 MAXIMUM PENALTY VAN COMPACTED SUBGRADE BASE COURSE AGGREGATE SURFACE COURSE TYPE SF9.5A 3-IN 8-IN TYPICAL PAVEMENT SECTIONS NOT TO SCALE TRAVEL 2-IN 6-IN WITHIN PAVING ON-SITE AISLES PARKING WITHIN PAVING ON-SITE STALLS DUTY DUTY HEAVY LIGHT STEEL BOLLARD NOT TO SCALE 6" O.D. SCHEDULE 40 STEEL PIPE ROUND OFF TOP OFCONCRETE FILL COLOR: TO BE SELECTED CONCRETE FOOTING ANCHOR PIPE IN 3'-6"2'-6"6"FILL WITH CONCRETE BY ARCHITECT. CONCRETE PAVING COMPACTEDSUBGRADE 2'-6" (3000 PSI)6'-4"7'-4"1'BRICK SOLDIER COURSE BRICK ROWLOCK 3'-8" INSTALL #4 REBAR AT 24" O.C. VERTICAL, TIE INTO REBAR EMBEDDED IN FOOTING AND EXTENDING INTO CAVITY, FILL CAVITY WITH GROUT OR MORTAR. BRICK MASONRY VENEER TO MATCH BUILDINGS. FOUNDATION AND WALL SECTION DESIGNED FOR 130 MPH WIND LOADING CONDITION FOR MAX. 24 FOOT BY 10 FOOT OVERALL DIMENSIONS. CONCRETE FOOTING WITH 5 EACH #4 REBAR LONG, 1 EA #4 24" O.C. WIDTHWAYS. 0'-0" FINISHED FLOOR FINSHED GRADE, SEE CIVIL CONT. 24"x 12" CONC. FOOTING W/ (2) #5 BARS (TYP.) 12" CMU, FILL SOLID BELOW SLAB (TYP.) 8" CMU HORIZONTAL JOINT REINFORCING @ 16" O.C. (TYP.) CONT. THRU-WALL FLASHING BELOW CONT. CMU BOND BEAM FULL PERIMETER @ TOP OF WALL (TYP.) 12" EXPANSION JOINT FULL PERIMETER OF DUMPSTER PAD (TYP.) 6" CONC. SLAB W/ W.W.F. OVER STONE BASE & WELL COMPACTED SOIL (TYP.) TOP OF MASONRY BRICK VENEER, "HANSON #222 RED WIRE-CUT" (TYP.) FLUSH METAL PANELS (DARK BRONZE) ON 2x2 TUBE STEEL WELDED FRAME W/ DIAGONAL CROSS BRACE. 8" PIPE BOLLARD, PAINT "GLOSS BLACK" EXTEND PIPE BOLLARD 36" BELOW FINISHED GRADE SET IN 24"x24" CONC. FOOTING. TOP OF MASONRY NOTE: PAINT CMU INSIDE ENCLOSURE (TYP.) 8" BOND BEAM COPING CAP SLOPED FOR POSITIVE DRAINAGE, COLOR TO MATCH BRICK SOLDIER COURSE (TYP.) PRESSURE TREATED 2x WOOD BLOCKING (TYP.) WALL SECTION TYPICAL ELEVATION PLAN PAINTED STEEL BOLLARDS 6" CONCRETE SLAB C.J.12'-0"30" CURB AND GUTTER 30" CURB AND GUTTER 4" BRICK VENEER, "HANSON #222 RED WIRE-CUT (TYP.) 12'-4"16'-0"1'-0"14'-0"1'-0"1'-0" 1'-0" 4" BRICK 8" CMU COPING CAP SLOPED FOR POSITIVE DRAINAGE, COLOR TO MATCH BRICK SOLDIER COURSE (TYP.) BRICK SOLDIER COURSE, "HANSON #721 LT GREAY WIRE-CUT". BRICK SOLDIER COURSE, "HANSON #721 LT. GREY WIRE-CUT" (TYP.) NOTE: DUMPSTER SCREENING SHOWN IN THIS PLAN SUBMITTAL IS FOR APPROVAL OF SIZE & APPEARANCE ONLY, ALL CONSTRUCTION DETAILS SHALL BE APPROVED BY THE BUILDING DEPARTMENT AT TIME WHICH PROJECT IS SUBMITTED FOR PERMITTING.3'-0"4'-0"4'-0"3'-0"1'-0" TOP OF MASONRY 6'-0" A.F.F. ASSUMED THE ENCLOSURE HEIGHT SHALL BE 1' HIGHER THAN THE CHOSEN CONTAINER HEIGHT, MINIMUM. DUMPSTER ENCLOSURE NOT TO SCALE C6.3 NOTES AND DETAILSJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C7.0-NTDT.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN STEEL POSTS - TENSTAR ORANGE SAFETY BARRIER 10' MAX SIGNS SPACED 75' O.C. Prohibido Entrar los arboles/ Zona Protectora para No Trespassing Tree Protection Area/4' MAX.TREE PROTECTION FENCING NTS NOTE: TREE PROTECTION FENCING MUST BE ON IT'S OWN POLE. CANNOT SHARE POLES WITH SILT FENCE. TREE PROTECTION SIGN NTS C6.4 NOTES AND DETAILSJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C7.0-NTDT.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN SSS SAN SAN 3+02. 2 2 0+00 0+50 1+00 1+50 2+00 2+50 3+00 186 180 175 170 164 161 187 183 182 178 190 187 182 183 178 178 183 182FES 100 RISER FES 200 CB 101 24" RCP 24" RCP HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 POND PROFILE 160 165 170 175 180 185 190 195 200 160 165 170 175 180 185 190 195 200 191.5191.0187.9185.2185.2179.5172.8191.00178.00178.00178.00178.00-0+50 0+00 1+00 2+00 3+00 4+00 92 L F 24 " R C P @ 6 . 5 9 % 61 LF 24" RCP @ 1.63% FES 100 TOP 181.25 INV IN 179.00 (FR CB 101) FES 200 TOP 182.25 INV IN 180.00 (FR RISER) RISER TOP 185.50 INV OUT 181.00 (TO FES 200) EXISTING GRADE FOREBAY FOREBAY BERM 2:12:12:13:1RISER, SEE DETAIL THIS SHEET PROPOSED GRADE PERM POOL=182.00 6' VEG. SHELF SLOPE=6:1 (TYP.)2:1BOTTOM OF POND, ELEV=178.003:1 EMERGENCY SPILLWAY ELEV=185.50 6' VEG. SHELF SLOPE=6:1 (TYP.) 10' TOP OF BERM ELEV=187.00 BOTTOM OF SEDIMENT STORAGE, ELEV=177.00 100-YR WSE ELEV=186.00 1.00' FREEBOARD SCALE 1"=50' 100'50'0 C6.5 WET POND DETAILSNAD 83JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C11.0-POND.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. PROFILE SCALE 0 0 50 5 FOREBAY 6' VEG. SHELF 10' BERM PERM POOL = 182.00 EMERGENCY SPILLWAY 10' BERM 6'W X 18'L X 18"T CLASS A RIPRAP QUILL SEDGE (CEREX TENERA) VIRGINIA SWEETSPIRE (ITEA VIRGINICA) JOE PYE WEED (EUPAT' FISTULOSUS) PLANTING PLAN LEGEND SEE POND PLANT LIST THIS SHEET 1992002012022032 0 3 2 0 2 2 0 1 2 0 0 200197194195 192 190 195188191192198 198 1 9 7 1 9 7 1 9 6 198 200 198197 196 192 188189 180181 183184 1871821851801751878''W8''W8''W8''W8''W8''W 6' 'W6''W6' 'W6' 'W6' 'W8''W 8''W8''W8''W S SSANS SA N SANSANSSSANSANS SANSANSANSANS SANS C10.0 PLANTING PLANJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C10.0-PLNT.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN 0 SCALE 1"=40' 80'40'NAD 83KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. LEGEND PROPERTY LINE PERIMETER BUFFER PROPOSED RIGHT-OF-WAY PROPOSED LOT LINE DRAINAGE EASEMENT SANITARY SEWER EASEMENT PHASE LINE PROPOSED 100 YR FLOODPLAIN PROPOSED CENTERLINE ADJACENT PROPERTY LINE EXISTING ROAD CENTERLINE EXISTING RIGHT-OF-WAY PROPOSED EOP BUILDING SETBACK EXISTING WETLANDS NEUSE RIPARIAN BUFFER CIVIC SPACE CREEK CENTERLINE 140' OF SUCCESSIONAL GROWTH TO UNDISTURBED BOUNDARY IN ASSOCIATION WITH BUFFERED CREEK. 14 0 ' UNDISTURBED OLD GROWTH VEGETATION 200' WIDE TO NEXT RESIDENCE 20 0 ' QR-TYP QR-TYP AR-TYP AR-TYP AR-TYP AR-TYP QR-TYP QR-TYP AS-TYP AS-TYP AS-TYP AS-TYP AS-TYP AS-TYP NORTHERN BOUNDARY 690.07' TYPE A BUFFER WESTERN BOUNDARY 1386.70' TYPE A BUFFER EASTERN BOUNDARY 680' STREETSCAPE BUFFER SOUTHERN BOUNDARY 150' TYPE A BUFFER 30.00'30.00' JV-TYP AS-TYP QR-TYP AR-TYP AG-TYP AG-TYPAG-TYP A-GT-TYP A-GT-TYP A-GT-TYP A-F-TYP A-F-TYPA-F-TYP A-F-TYP LC-TYP LC-TYP LC-TYP QR-TYP LJ-TYP LJ-TYP LJ-TYP MC-TYP MC-TYP SP-TYP SP-TYP15.00'5.00'5.00'5.00'15.00'300.00' TYPICAL TYPICAL BUFFER PLANTING - NATURALIZED C10.1 PLANTING PLANJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICENORTH CAROLINA LICENSE NO. C-1652S:\331\47667-Buies_Creek_TH\DWG\Sheet\CD\47667-331-C10.0-PLNT.dwg | Plotted by Michael LanzaFOR REVIEWONLY06/02/2021 BUIES CREEK TOWNHOMESHARNETT COUNTY, NORTH CAROLINA47667 331 331 K. ROBERTS AS SHOWN KNOW WHAT'S BELOW. CALL 811 BEFORE YOU DIG. 30.00'30.00' JV-TYP AS-TYP QR-TYP AR-TYP AG-TYP AG-TYPAG-TYP A-GT-TYP A-GT-TYP A-GT-TYP A-F-TYP A-F-TYPA-F-TYP A-F-TYP LC-TYP LC-TYP LC-TYP QR-TYP LJ-TYP LJ-TYP LJ-TYP MC-TYP MC-TYP SP-TYP SP-TYP15.00'5.00'5.00'5.00'15.00'300.00' TYPICAL TYPICAL BUFFER PLANTING - NATURALIZED C8.0