OWNER/DEVELOPER
OAKMONT DEVELOPMENT PARTNERS, LLC.
109 HAY STREET, SUITE 301
FAYETTEVILLE, NC 28301
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
GENERAL NOTE:
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THIS PROJECT
WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO
THE SPECIFICATIONS OR APPLICABLE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN
WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE
ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF THE WORK AS DEFINED BY THE DRAWINGS AND IN
FULL CONFORMANCE WITH LOCAL REGULATIONS AND CODES.
REFERENCES
¨BOUNDARY & TOPOGRAPHIC SURVEY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
¨ENVIRONMENTAL :
SOIL & ENVIRONMENTAL CONSULTANTS, PA
8412 FALLS OF NEUSE ROAD
SUITE 104
RALEIGH, NC 27615
1-(919)-846-5900
THE ABOVE REFERENCED DOCUMENTS ARE INCORPORATED BY REFERENCE AS PART OF THESE PLANS, HOWEVER,
BOHLER DOES NOT CERTIFY THE ACCURACY OF THE WORK REFERENCED OR DERIVED FROM THESE DOCUMENTS, BY
OTHERS.
PLAN REFERENCES AND CONTACTS
OAKMONT SUBDIVISION
PHASE III PLAT PLANS
OAKMONT DEVELOPMENT PARTNERS, LLC.
PROPOSED
SUBDIVISION
LOCATION OF SITE
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
FOR
LOCATION MAP
NCBELS P-1132
CONTACT: GARY ZURAWSKI, P.E.
PREPARED BY
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-101 COVER SHEETJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-101
COVER SHEET
SDP-0
SHEET LIST TABLE
Sheet Number Sheet Title
C-101 COVER SHEET
C-102 GENERAL NOTES
C-103 DEVELOPER'S REQUIRMENTS & GENERAL NOTES
C-104 LEGENDS AND ABBREVIATIONS
C-105 BOUNDARY & TOPOGRAPHIC SURVEY
C-106 BOUNDARY & TOPOGRAPHIC SURVEY
C-107 BOUNDARY & TOPOGRAPHIC SURVEY
C-108 BOUNDARY & TOPOGRAPHIC SURVEY
C-109 BOUNDARY & TOPOGRAPHIC SURVEY
C-110 KEY MAP
C-111 PHASING PLAN
C-112 MASTER LOT MAP
C-113 MASTER LOT MAP - A
C-114 MASTER LOT MAP - B
C-115 MASTER LOT MAP - C
C-116 MASTER LOT MAP - D
C-117 MASTER LOT MAP - E
C-200 OVERALL DEMO & PH 1 EROSION PLAN
C-201 DEMO & PHASE I EROSION CONTROL PLAN - A
C-202 DEMO & PHASE I EROSION CONTROL PLAN - B
C-203 DEMO & PHASE I EROSION CONTROL PLAN - C
C-204 DEMO & PHASE I EROSION CONTROL PLAN - D
C-205 DEMO & PHASE I EROSION CONTROL PLAN - E
C-206 DEMO & PHASE I EROSION CONTROL PLAN - F
C-207 DEMO & PHASE I EROSION CONTROL PLAN - G
C-208 DEMO & PHASE I EROSION CONTROL PLAN - H
C-209 DEMO & PHASE I EROSION CONTROL PLAN - I
C-210 DEMO & PHASE I EROSION CONTROL PLAN - J
C-211 DEMO & PHASE I EROSION CONTROL PLAN - K
C-212 DEMO & PHASE I EROSION CONTROL PLAN - L
C-213 DEMO & PHASE I EROSION CONTROL PLAN - M
C-214 DEMO & PHASE I EROSION CONTROL PLAN - N
C-300 OVERALL PH2 EROSION PLAN
C-301 SITE & PHASE II EROSION CONTROL PLAN - A
C-302 SITE & PHASE II EROSION CONTROL PLAN - B
C-303 SITE & PHASE II EROSION CONTROL PLAN - C
C-304 SITE & PHASE II EROSION CONTROL PLAN - D
C-305 SITE & PHASE II EROSION CONTROL PLAN - E
C-306 SITE & PHASE II EROSION CONTROL PLAN - F
C-307 SITE & PHASE II EROSION CONTROL PLAN - G
C-308 SITE & PHASE II EROSION CONTROL PLAN - H
C-309 SITE & PHASE II EROSION CONTROL PLAN - I
C-310 SITE & PHASE II EROSION CONTROL PLAN - J
C-311 SITE & PHASE II EROSION CONTROL PLAN - K
C-312 SITE & PHASE II EROSION CONTROL PLAN - L
C-313 SITE & PHASE II EROSION CONTROL PLAN - M
C-314 SITE & PHASE II EROSION CONTROL PLAN - N
C-400 OVERALL GRADING AND DRAINAGE PLAN
C-401 GRADING AND DRAINAGE PLAN - A
C-402 GRADING AND DRAINAGE PLAN - B
C-403 GRADING AND DRAINAGE PLAN - C
C-404 GRADING AND DRAINAGE PLAN - D
C-405 GRADING AND DRAINAGE PLAN - E
C-406 GRADING AND DRAINAGE PLAN - F
C-407 GRADING AND DRAINAGE PLAN - G
C-408 GRADING AND DRAINAGE PLAN - H
C-409 GRADING AND DRAINAGE PLAN - I
C-410 GRADING AND DRAINAGE PLAN - J
C-411 GRADING AND DRAINAGE PLAN - K
C-412 GRADING AND DRAINAGE PLAN - L
C-413 GRADING AND DRAINAGE PLAN - M
C-414 GRADING AND DRAINAGE PLAN - N
C-415 STORM SEWER PROFILES
C-416 STORM SEWER PROFILES
C-417 STORM SEWER PROFILES
C-418 STORM SEWER PROFILES
C-419 STORM SEWER PROFILES
C-420 STORM SEWER PROFILES
C-421 STORM SEWER PROFILES
C-422 STORM SEWER PROFILES
C-423 STORM SEWER PROFILES
C-424 STORM SEWER SCHEDULES
C-500 OVERALL UTILITY PLAN
C-501 UTILITY PLAN - A
C-502 UTILITY PLAN - B
C-503 UTILITY PLAN - C
C-504 UTILITY PLAN - D
C-505 UTILITY PLAN - E
C-506 UTILITY PLAN - F
C-507 UTILITY PLAN - G
C-508 UTILITY PLAN - H
C-509 UTILITY PLAN - I
C-510 UTILITY PLAN - J
C-511 UTILITY PLAN - K
C-512 UTILITY PLAN - L
C-513 UTILITY PLAN - M
C-514 UTILITY PLAN - N
C-901 SITE DETAILS
C-902 SITE DETAILS
C-903 SITE DETAILS
C -904 STORM DETAILS
C -905 SANITARY DETAILS
C -906 WATER DETAILS
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ADDRESS:DOCS ROAD & EXECUTIVE DRIVE
BARBECUE, NC 27546
PROJECT JURISDICTION HARNETT COUNTY
PIN #:0507-53-6396.000
LAND USE CLASSIFICATION: LDR (LOW DENSITY RESIDENTIAL)
DEED REFERENCE:BOOK 3662, PAGE 0762
SITE AREA: (AC.)± 325.12 AC
EXISTING ZONING:RA-20R (PLAN COMPLIES)
PROP. USE:RESIDENTIAL
WATERSHED:ROCKY RUN CREEK - UPPER LITTLE RIVER
(CAPE FEAR BASIN)
WATERSHED CLASSIFICATION: WS-IV (UPPER LITTLE RIVER)
FLOOD ZONE CLASSIFICATION:ZONE X
FEMA MAP NUMBER:3720050600J
MAP DATE:10/03/2006
EXISTING # OF LOTS FROM PHASES I/II:243
PROPOSED # OF LOTS IN PHASE III:129
TOTAL PROPOSED LOTS:372
PROPOSED DENSITY: (DU/AC.)±1.14
PROPOSED MINIMUM LOT SIZE: (SF)20,000
PROPOSED MINIMUM LOT WIDTH: (FT)80
SETBACKS
FRONT YARD: 35'
SIDE YARD:10'
CORNER SIDE YARD:20'
CORNER SIDE YARD, MAJOR ROAD:35'
REAR YARD:25'
MAX BUILDING HEIGHT: (FT)35'
PARKING
PROPOSED # OF SPACES:2/UNIT
OPEN SPACE
REQUIRED OPEN SPACE: 0%
INFRASTRUCTURE QUANTITIES
STREETS: (LF)± 9,430
FIRE WATERLINE (6"): (LF)± 7,420
DOMESTIC WATERLINE (1"): (LF)± 2,381
SANITARY SEWER: (LF)0
FORCE MAIN: (LF) 0
AVERAGE SEWER FLOW: (GPD)N/A
PROPOSED # OF DOMESTIC WATER TAPS:129
PROPOSED # OF SEWER TAPS:0
IMPERVIOUS SURFACES
STREETS: (SF)NOT APPLICABLE
LOTS: (SF) NOT APPLICABLE
TOTAL: (SF)NOT APPLICABLE
MAX OVERALL IMPERVIOUS N/A (MAX 3.0 DU/AC)*
AVERAGE IMPERVIOUS PER LOT NOT APPLICABLE
PERCENT PROP. IMPERVIOUS: (%)NOT APPLICABLE
*HARNETT COUNTY DOES NOT SPECIFY A MAX IMPERVIOUS COVERAGE FOR SINGLE FAMILY
RESIDENTIAL USES
SITE DATA
DEMOLITION NOTES (Rev. 1/2020)
1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE
CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO
THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND
ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.
2.THE CONTRACTOR MUST CONDUCT DEMOLITION/REMOVALS ACTIVITIES IN SUCH A MANNER AS TO ENSURE MINIMUM
INTERFERENCE WITH ROADS, STREETS, SIDEWALKS, WALKWAYS, AND ALL OTHER ADJACENT FACILITIES. THE
CONTRACTOR MUST OBTAIN ALL APPLICABLE PERMITS FROM THE APPROPRIATE GOVERNMENTAL AUTHORITY(IES)
PRIOR TO THE COMMENCEMENT OF ANY ROAD OPENING OR DEMOLITION ACTIVITIES IN OR ADJACENT TO THE
RIGHT-OF-WAY.
3.WHEN DEMOLITION-RELATED ACTIVITIES IMPACT ROADWAYS AND/OR ROADWAY RIGHT-OF-WAY, THE CONTRACTOR
MUST PROVIDE TRAFFIC CONTROL AND GENERALLY ACCEPTED SAFE PRACTICES IN CONFORMANCE WITH THE
CURRENT FEDERAL HIGHWAY ADMINISTRATION "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" (MUTCD), AND THE
FEDERAL, STATE, AND LOCAL REGULATIONS.
4.THE DEMOLITION (AND/OR REMOVALS) PLAN IS INTENDED TO PROVIDE GENERAL INFORMATION AND TO IDENTIFY ONLY
CONDITIONS REGARDING ITEMS TO BE DEMOLISHED, REMOVED, AND/OR TO REMAIN.
A.THE CONTRACTOR MUST ALSO REVIEW ALL CONSTRUCTION DOCUMENTS AND INCLUDE WITHIN THE DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
B.THIS PLAN IS NOT INTENDED TO AND DOES NOT PROVIDE DIRECTION REGARDING THE MEANS, METHODS,
SEQUENCING, TECHNIQUES AND PROCEDURES TO BE EMPLOYED TO ACCOMPLISH THE WORK. ALL MEANS,
METHODS, SEQUENCING, TECHNIQUES AND PROCEDURES TO BE USED MUST BE IN STRICT ACCORDANCE AND
CONFORMANCE WITH ALL STATE, FEDERAL, LOCAL, AND JURISDICTIONAL REQUIREMENTS. THE CONTRACTOR
MUST COMPLY WITH ALL OSHA AND OTHER SAFETY PRECAUTIONS NECESSARY TO PROVIDE A SAFE WORK SITE
FOR THE CONTRACTOR AND THE PUBLIC.
5.THE CONTRACTOR MUST PROVIDE ALL "METHODS AND MEANS" NECESSARY TO PREVENT MOVEMENT, SETTLEMENT,
OR COLLAPSE OF EXISTING STRUCTURES, AND ANY OTHER IMPROVEMENTS THAT ARE REMAINING ON OR OFF SITE.
THE CONTRACTOR, AT THE CONTRACTOR'S SOLE COST, MUST REPAIR ALL DAMAGE TO ALL ITEMS AND FEATURES THAT
ARE TO REMAIN. CONTRACTOR MUST USE NEW MATERIAL FOR ALL REPAIRS. CONTRACTOR'S REPAIRS MUST INCLUDE
THE RESTORATION OF ALL ITEMS AND FEATURES REPAIRED TO THEIR PRE-DEMOLITION CONDITION, OR BETTER.
CONTRACTOR MUST PERFORM ALL REPAIRS AT THE CONTRACTOR'S SOLE EXPENSE.
6.ENGINEER OF RECORD AND/OR BOHLER ARE NOT RESPONSIBLE FOR JOB SITE SAFETY OR SUPERVISION. THE
CONTRACTOR MUST PROCEED WITH THE DEMOLITION IN A SYSTEMATIC AND SAFE MANNER, COMPLYING WITH ALL
OSHA REQUIREMENTS, TO ENSURE PUBLIC AND CONTRACTOR SAFETY AND SAFETY TO ALL PROPERTY ON THE SITE
OR ADJACENT OR NEAR TO THE SAME.
7.THE CONTRACTOR IS RESPONSIBLE FOR JOB SITE SAFETY, WHICH MUST INCLUDE, BUT IS NOT LIMITED TO, THE
INSTALLATION AND MAINTENANCE OF BARRIERS, FENCING, OTHER APPROPRIATE AND/OR NECESSARY SAFETY
FEATURES AND ITEMS NECESSARY TO PROTECT THE PUBLIC FROM AREAS OF CONSTRUCTION AND CONSTRUCTION
ACTIVITIES. THE CONTRACTOR MUST SAFEGUARD THE SITE AS NECESSARY TO PERFORM THE DEMOLITION IN SUCH A
MANNER AS TO PREVENT THE ENTRY OF ALL UNAUTHORIZED PERSONS AT ANY TIME, TO OR NEAR THE DEMOLITION
AREA.
8.PRIOR TO THE COMMENCEMENT OF ANY SITE ACTIVITY AND ANY DEMOLITION ACTIVITY, THE CONTRACTOR MUST, IN
WRITING, RAISE ANY QUESTIONS CONCERNING THE ACCURACY OR INTENT OF THESE PLANS AND/OR SPECIFICATIONS,
ALL CONCERNS OR QUESTIONS REGARDING THE APPLICABLE SAFETY STANDARDS, AND/OR THE SAFETY OF THE
CONTRACTOR AND/OR THIRD PARTIES IN PERFORMING THE WORK ON THIS PROJECT. ANY SUCH CONCERNS MUST BE
CONVEYED TO THE ENGINEER OF RECORD AND/OR BOHLER , IN WRITING AND MUST ADDRESS ALL ISSUES AND ITEMS
RESPONDED TO, BY THE ENGINEER OF RECORD AND/OR BY BOHLER , IN WRITING. ALL DEMOLITION ACTIVITIES MUST
BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS AND SPECIFICATIONS AND ALL
APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS, RULES, REQUIREMENTS, STATUTES, ORDINANCES AND
CODES.
9.THE CONTRACTOR MUST BECOME FAMILIAR WITH THE APPLICABLE UTILITY SERVICE PROVIDER REQUIREMENTS AND IS
RESPONSIBLE FOR ALL COORDINATION REGARDING UTILITY DEMOLITION AND/OR DISCONNECTION AS IDENTIFIED OR
REQUIRED FOR THE PROJECT. THE CONTRACTOR MUST PROVIDE THE OWNER WITH WRITTEN NOTIFICATION THAT THE
EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED, REMOVED AND/OR ABANDONED IN ACCORDANCE WITH
THE JURISDICTION AND UTILITY COMPANY REQUIREMENTS AND ALL OTHER APPLICABLE REQUIREMENTS, RULES,
STATUTES, LAWS, ORDINANCES AND CODES.
10.PRIOR TO COMMENCING ANY DEMOLITION, THE CONTRACTOR MUST:
A.OBTAIN ALL REQUIRED PERMITS AND MAINTAIN THE SAME ON SITE FOR REVIEW BY THE ENGINEER AND ALL PUBLIC
AGENCIES WITH JURISDICTION THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK, AND DEMOLITION
WORK.
B.NOTIFY, AT A MINIMUM, THE MUNICIPAL ENGINEER, DESIGN ENGINEER, AND LOCAL SOIL CONSERVATION
JURISDICTION, AT LEAST 72 BUSINESS HOURS PRIOR TO THE COMMENCEMENT OF WORK.
C.INSTALL THE REQUIRED SOIL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO SITE DISTURBANCE, AND
MAINTAIN SAID CONTROLS UNTIL SITE IS STABILIZED
D.IN ACCORDANCE WITH STATE LAW, THE CONTRACTOR MUST CALL THE STATE ONE-CALL DAMAGE PROTECTION
SYSTEM FOR UTILITY MARK OUT, IN ADVANCE OF ANY EXCAVATION.
E.LOCATE AND PROTECT ALL UTILITIES AND SERVICES, INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC,
SANITARY AND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN AND ADJACENT TO THE
LIMITS OF PROJECT ACTIVITIES. THE CONTRACTOR MUST USE AND COMPLY WITH THE REQUIREMENTS OF THE
APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL UNDERGROUND UTILITIES.
F.PROTECT AND MAINTAIN IN OPERATION, ALL ACTIVE UTILITIES AND SYSTEMS THAT ARE NOT BEING REMOVED
DURING ANY DEMOLITION ACTIVITIES.
G.ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) FOR THE TEMPORARY OR
PERMANENT TERMINATION OF SERVICE REQUIRED BY THE PROJECT PLANS AND SPECIFICATIONS REGARDING THE
METHODS AND MEANS TO CONSTRUCT SAME. THESE ARE NOT THE ENGINEER OF RECORD'S RESPONSIBILITY. IN
THE EVENT OF ABANDONMENT, THE CONTRACTOR MUST PROVIDE THE UTILITY ENGINEER AND OWNER WITH
IMMEDIATE WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED AND
ABANDONED IN ACCORDANCE WITH JURISDICTIONAL AND UTILITY COMPANY REQUIREMENTS.
H.ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) REGARDING WORKING
"OFF-PEAK" HOURS OR ON WEEKENDS AS NECESSARY OR AS REQUIRED TO MINIMIZE THE IMPACT ON, OF AND TO
THE AFFECTED PARTIES. WORK REQUIRED TO BE PERFORMED "OFF-PEAK" IS TO BE PERFORMED AT NO
ADDITIONAL COST TO THE OWNER.
I.IN THE EVENT THE CONTRACTOR DISCOVERS ANY HAZARDOUS MATERIAL, THE REMOVAL OF WHICH IS NOT
ADDRESSED IN THE PROJECT PLANS AND SPECIFICATIONS, OR THE CONTRACT WITH THE OWNER/DEVELOPER,
THE CONTRACTOR MUST IMMEDIATELY CEASE ALL WORK IN THE AREA OF DISCOVERY, AND IMMEDIATELY NOTIFY,
IN WRITING AND VERBALLY, THE OWNER AND ENGINEER OF RECORD AND BOHLER , THE DISCOVERY OF SUCH
MATERIALS TO PURSUE PROPER AND COMPLIANT REMOVAL OF SAME.
11.THE CONTRACTOR MUST ENSURE THAT ANY EXISTING ASBESTOS-CONTAINING MATERIALS ENCOUNTERED ARE
PROPERLY REMOVED FROM THE SUBJECT PREMISES AND ARE DISPOSED OF IN ACCORDANCE WITH FEDERAL, STATE,
AND LOCAL REQUIREMENTS, PRIOR TO THE COMMENCEMENT OF DEMOLITION ON SITE AND MUST PERFORM ALL
AGENCY NOTIFICATIONS AS REQUIRED, AT THE CONTRACTOR'S SOLE EXPENSE.
12.THE CONTRACTOR MUST NOT PERFORM ANY EARTH MOVEMENT ACTIVITIES, DEMOLITION OR REMOVAL OF
FOUNDATION WALLS, FOOTINGS, OR OTHER MATERIALS WITHIN THE LIMITS OF DISTURBANCE, UNLESS SAME IS IN
STRICT ACCORDANCE AND CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS, OR PURSUANT TO THE
WRITTEN DIRECTION OF THE OWNER'S STRUCTURAL OR GEOTECHNICAL ENGINEER.
13.DEMOLITION ACTIVITIES AND EQUIPMENT MUST NOT USE OR INCLUDE AREAS OUTSIDE THE DEFINED PROJECT LIMIT
LINE, WITHOUT SPECIFIC WRITTEN PERMISSION AND AUTHORITY OF AND FROM THE OWNER AND ALL GOVERNMENTAL
AGENCIES WITH JURISDICTION.
14.THE CONTRACTOR MUST BACKFILL ALL EXCAVATION RESULTING FROM, OR INCIDENTAL TO, DEMOLITION ACTIVITIES.
BACKFILL MUST BE ACCOMPLISHED WITH APPROVED BACKFILL MATERIALS AND MUST BE SUFFICIENTLY COMPACTED
TO SUPPORT ALL NEW IMPROVEMENTS AND MUST BE PERFORMED IN COMPLIANCE WITH THE RECOMMENDATIONS
AND GUIDANCE ARTICULATED IN THE GEOTECHNICAL REPORT. BACKFILLING MUST OCCUR IMMEDIATELY AFTER
DEMOLITION ACTIVITIES AND MUST BE PERFORMED SO AS TO PREVENT WATER ENTERING THE EXCAVATION. FINISHED
SURFACES MUST BE GRADED TO PROMOTE POSITIVE DRAINAGE. THE CONTRACTOR IS RESPONSIBLE FOR
COMPACTION TESTING AND MUST SUBMIT SUCH REPORTS AND RESULTS TO THE ENGINEER OF RECORD AND THE
OWNER.
15.EXPLOSIVES MUST NOT BE USED WITHOUT PRIOR WRITTEN CONSENT FROM BOTH THE OWNER AND ALL APPLICABLE,
NECESSARY AND REQUIRED GOVERNMENTAL AUTHORITIES. PRIOR TO COMMENCING ANY EXPLOSIVE PROGRAM
AND/OR ANY DEMOLITION ACTIVITIES, THE CONTRACTOR MUST ENSURE AND OVERSEE THE INSTALLATION OF ALL OF
THE REQUIRED PERMIT AND EXPLOSIVE CONTROL MEASURES THAT THE FEDERAL, STATE, AND LOCAL GOVERNMENTS
REQUIRE. THE CONTRACTOR IS ALSO RESPONSIBLE TO CONDUCT AND PERFORM ALL INSPECTION AND SEISMIC
VIBRATION TESTING THAT IS REQUIRED TO MONITOR THE EFFECTS ON ALL LOCAL STRUCTURES AND THE LIKE.
16.IN ACCORDANCE WITH FEDERAL, STATE, AND/OR LOCAL STANDARDS, THE CONTRACTOR MUST USE DUST CONTROL
MEASURES TO LIMIT AIRBORNE DUST AND DIRT RISING AND SCATTERING IN THE AIR. AFTER THE DEMOLITION IS
COMPLETE, THE CONTRACTOR MUST CLEAN ALL ADJACENT STRUCTURES AND IMPROVEMENTS TO REMOVE ALL DUST
AND DEBRIS WHICH THE DEMOLITION OPERATIONS CAUSE. THE CONTRACTOR IS RESPONSIBLE FOR RETURNING ALL
ADJACENT AREAS TO THEIR "PRE-DEMOLITION" CONDITION AT CONTRACTOR'S SOLE COST.
17.PAVEMENT MUST BE SAW CUT IN STRAIGHT LINES, AND EXCEPT FOR EDGE OF BUTT JOINTS, MUST EXTEND TO THE
FULL DEPTH OF THE EXISTING PAVEMENT. ALL DEBRIS FROM REMOVAL OPERATIONS MUST BE REMOVED FROM THE
SITE AT THE TIME OF EXCAVATION. STOCKPILING OF DEBRIS OUTSIDE OF APPROVED AREAS WILL NOT BE PERMITTED,
INCLUDING BUT NOT LIMITED TO, THE PUBLIC RIGHT-OF-WAY.
18.THE CONTRACTOR MUST MAINTAIN A RECORD SET OF PLANS WHICH INDICATES THE LOCATION OF EXISTING UTILITIES
THAT ARE CAPPED, ABANDONED IN PLACE, OR RELOCATED DUE TO DEMOLITION ACTIVITIES. THIS RECORD DOCUMENT
MUST BE PREPARED IN A NEAT AND WORKMAN-LIKE MANNER AND TURNED OVER TO THE OWNER/DEVELOPER UPON
COMPLETION OF THE WORK, ALL OF WHICH IS AT THE CONTRACTOR'S SOLE COST.
19.THE CONTRACTOR MUST EMPTY, CLEAN AND REMOVE FROM THE SITE ALL UNDERGROUND STORAGE TANKS, IF
ENCOUNTERED, IN ACCORDANCE WITH FEDERAL, STATE, COUNTY AND LOCAL REQUIREMENTS, PRIOR TO CONTINUING
CONSTRUCTION IN THE AREA AROUND THE TANK WHICH EMPTYING, CLEANING AND REMOVAL ARE AT THE
CONTRACTOR'S SOLE COST.
SITE LAYOUT NOTES (Rev. 1/2020)
1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT
DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY
COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY
WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.
2.PRIOR TO THE COMMENCEMENT OF GENERAL CONSTRUCTION, THE CONTRACTOR MUST INSTALL SOIL EROSION CONTROL AND
ANY STORMWATER POLLUTION PREVENTION PLAN (SWPPP) MEASURES NECESSARY, AS INDICATED ON THE APPROVED SOIL
EROSION AND SEDIMENT CONTROL PLAN AND IN ACCORDANCE WITH APPLICABLE AND/OR APPROPRIATE AGENCIES' GUIDELINES
TO PREVENT SEDIMENT AND/OR LOOSE DEBRIS FROM WASHING ONTO ADJACENT PROPERTIES OR THE RIGHT OF WAY.
3.ALL DIRECTIONAL/TRAFFIC SIGNING AND PAVEMENT STRIPING MUST CONFORM TO THE LATEST STANDARDS OF THE MANUAL ON
UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND ANY APPLICABLE STATE OR LOCALLY APPROVED SUPPLEMENTS,
GUIDELINES, RULES, REGULATIONS, STANDARDS AND THE LIKE.
4.THE LOCATIONS OF PROPOSED UTILITY POLES AND TRAFFIC SIGNS SHOWN ON THE PLANS ARE SCHEMATIC AND PRELIMINARY.
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR FIELD-VERIFYING THEIR LOCATION. THE CONTRACTOR MUST COORDINATE THE
RELOCATION OF TRAFFIC SIGNS WITH THE ENTITY WITH JURISDICTION OVER THE PROJECT.
5.ALL DIMENSIONS SHOWN ARE TO BOTTOM FACE OF CURB, EDGE OF PAVEMENT, OR EDGE OF BUILDING, EXCEPT WHEN
DIMENSION IS TO A PROPERTY LINE, STAKE OUT OF LOCATIONS OF INLETS, LIGHT POLES, ETC. MUST BE PERFORMED IN STRICT
ACCORDANCE WITH THE DETAILS, UNLESS NOTED CLEARLY OTHERWISE.
GRADING NOTES (Rev.1/2020)
1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT
DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY
COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY
WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.
2.SITE GRADING MUST BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND THE RECOMMENDATIONS
SET FORTH IN THE GEOTECHNICAL REPORT AS REFERENCED IN THIS PLAN SET. IF NO GEOTECHNICAL REPORT HAS BEEN
REFERENCED, THE CONTRACTOR MUST HAVE A GEOTECHNICAL ENGINEER PROVIDE WRITTEN SPECIFICATIONS AND
RECOMMENDATIONS PRIOR TO THE CONTRACTOR COMMENCING THE GRADING WORK. THE CONTRACTOR MUST FOLLOW THE
REQUIREMENTS OF ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS, WHICH HAVE JURISDICTION OVER THIS PROJECT.
3.THE CONTRACTOR IS REQUIRED TO SECURE ALL NECESSARY AND/OR REQUIRED PERMITS AND APPROVALS FOR ALL OFF-SITE
MATERIAL SOURCES AND DISPOSAL FACILITIES. THE CONTRACTOR MUST SUPPLY A COPY OF APPROVALS TO THE ENGINEER OF
RECORD AND THE OWNER PRIOR TO THE CONTRACTOR COMMENCING ANY WORK.
4.THE CONTRACTOR IS FULLY RESPONSIBLE FOR VERIFYING EXISTING TOPOGRAPHIC INFORMATION AND UTILITY INVERT
ELEVATIONS PRIOR TO COMMENCING ANY CONSTRUCTION. SHOULD DISCREPANCIES BETWEEN THE PLANS AND INFORMATION
OBTAINED THROUGH FIELD VERIFICATIONS BE IDENTIFIED OR EXIST, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE
ENGINEER OF RECORD, IN WRITING.
5.THE CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REPLACING ALL UNSUITABLE MATERIALS WITH SUITABLE MATERIALS AS
SPECIFIED IN THE GEOTECHNICAL REPORT. THE CONTRACTOR MUST COMPACT ALL EXCAVATED OR FILLED AREAS IN STRICT
ACCORDANCE WITH THE GEOTECHNICAL REPORT'S GUIDANCE. MOISTURE CONTENT AT TIME OF PLACEMENT MUST BE SUBMITTED
IN A COMPACTION REPORT PREPARED BY A QUALIFIED GEOTECHNICAL ENGINEER, REGISTERED WITH THE STATE WHERE THE
WORK IS PERFORMED. THIS REPORT MUST VERIFY THAT ALL FILLED AREAS AND SUBGRADE AREAS WITHIN THE BUILDING PAD
AREA AND AREAS TO BE PAVED HAVE BEEN COMPACTED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS AND THE
RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS,
ORDINANCES AND CODES WHICH ARE IN EFFECT AND WHICH ARE APPLICABLE TO THE PROJECT. SUBBASE MATERIAL FOR
SIDEWALKS, CURB, OR ASPHALT MUST BE FREE OF ORGANICS AND OTHER UNSUITABLE MATERIALS. SHOULD SUBBASE BE
DEEMED UNSUITABLE BY OWNER/DEVELOPER, OR OWNER/DEVELOPER'S REPRESENTATIVE, SUBBASE MUST BE REMOVED AND
FILLED WITH APPROVED FILL MATERIAL, COMPACTED AS THE GEOTECHNICAL REPORT DIRECTS. EARTHWORK ACTIVITIES
INCLUDING, BUT NOT LIMITED TO, EXCAVATION, BACKFILL, AND COMPACTING MUST COMPLY WITH THE RECOMMENDATIONS IN
THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES.
EARTHWORK ACTIVITIES MUST COMPLY WITH THE STANDARD STATE DOT SPECIFICATIONS FOR ROADWAY CONSTRUCTION
(LATEST EDITION) AND ANY AMENDMENTS OR REVISIONS THERETO.
6.THE TOPS OF EXISTING MANHOLES, INLET STRUCTURES, AND SANITARY CLEANOUT MUST BE ADJUSTED, AS NECESSARY, TO
MATCH PROPOSED FINISHED GRADES WITH NO TRIPPING OR SAFETY HAZARD IN ACCORDANCE WITH ALL APPLICABLE
STANDARDS, REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES.
7.IN THE EVENT OF A DISCREPANCY(IES) AND/OR A CONFLICT(S) BETWEEN PLANS, OR RELATIVE TO OTHER PLANS, THE GRADING
PLAN TAKES PRECEDENCE AND CONTROLS. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN
WRITING, OF ANY DISCREPANCY(IES) AND/OR CONFLICT(S).
8.THE CONTRACTOR IS RESPONSIBLE TO IMPORT FILL OR EXPORT EXCESS MATERIAL AS NECESSARY TO CONFORM TO THE
PROPOSED GRADING, AND TO BACKFILL EXCAVATIONS FOR THE INSTALLATION OF UNDERGROUND IMPROVEMENTS.
ACCESSIBILITY DESIGN GUIDELINES (Rev. 1/2020)
1.ALL ACCESSIBLE (A.K.A. ADA) COMPONENTS AND ACCESSIBLE ROUTES MUST BE CONSTRUCTED TO MEET, AT A MINIMUM, THE
MORE STRINGENT OF: (A) THE REQUIREMENTS OF THE "AMERICANS WITH DISABILITIES ACT" (ADA) CODE (42 U.S.C. § 12101 ET
SEQ. AND 42 U.S.C. § 4151 ET SEQ.); AND (B) ANY APPLICABLE LOCAL AND STATE GUIDELINES, AND ANY AND ALL AMENDMENTS TO
BOTH, WHICH ARE IN EFFECT WHEN THESE PLANS WERE COMPLETED.
2.THE CONTRACTOR MUST REVIEW ALL DOCUMENTS REFERENCED IN THESE NOTES FOR ACCURACY, COMPLIANCE AND
CONSISTENCY WITH INDUSTRY GUIDELINES.
3.THE CONTRACTOR MUST EXERCISE APPROPRIATE CARE AND PRECISION IN CONSTRUCTION OF ACCESSIBLE (ADA) COMPONENTS
AND ACCESSIBLE ROUTES FOR THE SITE. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE OF TRAVEL FROM PARKING
SPACES, PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, AND INTER-BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING
ENTRANCE/EXIT, MUST COMPLY WITH THE ACCESSIBLE GUIDELINES AND REQUIREMENTS WHICH INCLUDE, BUT ARE NOT LIMITED
TO THE FOLLOWING:
A.ACCESSIBLE PARKING SPACES AND ACCESS AISLES SLOPES MUST NOT EXCEED 1:50 (2.0%) IN ANY DIRECTION.
B.PATH OF TRAVEL ALONG ACCESSIBLE ROUTE MUST PROVIDE A 36-INCHES MINIMUM WIDTH (48-INCHES PREFERRED), OR AS
SPECIFIED BY THE GOVERNING AGENCY. UNOBSTRUCTED WIDTH OF TRAVEL (CAR OVERHANGS AND/OR HANDRAILS) MUST
NOT REDUCE THIS MINIMUM WIDTH. THE SLOPE MUST NOT EXCEED 1:20 (5.0%) IN THE DIRECTION OF TRAVEL AND MUST NOT
EXCEED 1:50 (2.0%) IN CROSS SLOPE. WHERE ACCESSIBLE PATH OF TRAVEL IS GREATER THAN 1:20 (5.0%), AN ACCESSIBLE
RAMP MUST BE PROVIDED. ALONG THE ACCESSIBLE PATH OF TRAVEL, OPENINGS MUST NOT EXCEED 1/2-INCH IN WIDTH.
VERTICAL CHANGES OF UP TO 1/2-INCH ARE PERMITTED ONLY IF THEY INCLUDES A 1/4-INCH BEVEL AT A SLOPE NOT STEEPER
THAN 1:2. NO VERTICAL CHANGES OVER 1/4-INCH ARE PERMITTED.
C.ACCESSIBLE RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%) AND A RISE OF 30-INCHES. LEVEL LANDINGS MUST BE
PROVIDED AT EACH END OF ACCESSIBLE RAMPS. LANDING MUST PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES,
AND MUST NOT EXCEED 1:50 (2.0%) SLOPE IN ANY DIRECTION. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT
LANDINGS MUST HAVE A CLEAR LANDING OF A MINIMUM OF 60-INCHES BY 60-INCHES. HAND RAILS ON BOTH SIDES OF THE
RAMP MUST BE PROVIDED ON AN ACCESSIBLE RAMP WITH A RISE GREATER THAN 6-INCHES.
D.ACCESSIBLE CURB RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%). WHERE FLARED SIDES ARE PROVIDED, THEY MUST
NOT EXCEED 1:10 (10%) SLOPE. LEVEL LANDING MUST BE PROVIDED AT RAMPS TOP AT A MINIMUM OF 36-INCHES LONG
(48-INCHES PREFERRED). IN ALTERATIONS, WHEN THERE IS NO LANDING AT THE TOP, FLARE SIDES SLOPES MUST NOT
EXCEED A SLOPE OF 1:12 (8.3%).
E.DOORWAY LANDINGS AREAS MUST BE PROVIDED ON THE EXTERIOR SIDE OF ANY DOOR LEADING TO AN ACCESSIBLE PATH
OF TRAVEL. THIS LANDING MUST BE SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (2.0%) FOR POSITIVE DRAINAGE.
THIS LANDING AREA MUST BE NO FEWER THAN 60-INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE CLEARLY PERMITTED
BY ACCESSIBLE STANDARDS FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICC/ANSI A117.1-2009 AND OTHER
REFERENCES INCORPORATED BY CODE).
F.WHEN THE PROPOSED CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO
ACCESSIBLE COMPONENTS FROM EXISTING DOORWAYS OR SURFACES, THE CONTRACTOR MUST VERIFY ALL EXISTING
ELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FOR
ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE CIRCUMSTANCES. THE CONTRACTOR MUST
IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT
DIFFER IN ANY WAY OR IN ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS BEFORE COMMENCING ANY WORK.
CONSTRUCTED IMPROVEMENTS MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THE BARRIER
FREE REGULATIONS AND THE ACCESSIBLE GUIDELINES.
G.THE CONTRACTOR MUST VERIFY ALL OF THE SLOPES OF THE CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY
NON-CONFORMANCE EXISTS OR IS OBSERVED OR DISCOVERED, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE
ENGINEER OF RECORD, IN WRITING, PRIOR TO POURING CONCRETE. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL
COSTS TO REMOVE, REPAIR AND/OR REPLACE NON-CONFORMING CONCRETE AND/OR PAVEMENT SURFACES.
4.IT IS STRONGLY RECOMMENDED THAT THE CONTRACTOR REVIEW THE INTENDED CONSTRUCTION TO ENSURE SAME IS
CONSISTENT WITH THE LOCAL BUILDING CODE PRIOR TO COMMENCING CONSTRUCTION.
LIGHTING NOTES (Rev. 1/2020)
1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE
CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM
AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND
ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.
2.THE LIGHTING CONTRACTOR MUST COMPLY WITH ALL APPLICABLE CONTRACTOR REQUIREMENTS INDICATED IN THE PLANS,
INCLUDING BUT NOT LIMITED TO GENERAL NOTES, GRADING AND UTILITY NOTES, SITE SAFETY, AND ALL AGENCY AND
GOVERNMENTAL REGULATIONS.
3.THE LIGHTING PLAN DEPICTS PROPOSED, SUSTAINED ILLUMINATION LEVELS CALCULATED USING DATA PROVIDED BY THE
NOTED MANUFACTURER. ACTUAL SUSTAINED SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY
DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS, THE SERVICE LIFE OF EQUIPMENT AND
LUMINAIRES AND OTHER RELATED VARIABLE FIELD CONDITIONS.
4.THE LIGHTING VALUES AND CALCULATION POINTS DEPICTED ON THIS PLAN ARE ANALYZED ON A HORIZONTAL GEOMETRIC
PLANE AT GROUND LEVEL UNLESS OTHERWISE NOTED. ILLUMINATION LEVELS ARE SHOWN IN FOOT-CANDLES (FC).
5.THE LUMINAIRES, LAMPS AND LENSES MUST BE REGULARLY INSPECTED/MAINTAINED TO ENSURE THAT THEY FUNCTION
PROPERLY. THIS WORK SHOULD INCLUDE, BUT IS NOT LIMITED TO, VISUAL OBSERVATION, CLEANING OF LENSES, AND
RE-LAMPING ACCORDING TO MANUFACTURER RECOMMENDATIONS. FAILURE TO FOLLOW THE ABOVE STEPS COULD RESULT
IN IMPROPER LIGHT DISTRIBUTION AND FAILURE TO COMPLY WITH THE APPROVED DESIGN. UPON COMPLETION AND
OWNER'S ACCEPTANCE OF THE WORK, THE ABOVE RESPONSIBILITIES BECOMES SOLELY THE OWNER'S.
6.THE LIGHTING PLAN IS INTENDED TO SHOW THE LOCATIONS AND TYPE OF LUMINAIRES. POWER SYSTEM, CONDUITS, WIRING
AND OTHER ELECTRICAL COMPONENTS ARE SOLELY THE ARCHITECT'S, MECHANICAL ENGINEER'S AND/OR LIGHTING
CONTRACTOR'S RESPONSIBILITY, AS INDICATED IN THE CONSTRUCTION CONTRACT DOCUMENTS. THE LIGHTING
CONTRACTOR MUST COORDINATE WITH THE PROJECT ARCHITECT AND/OR ELECTRICAL ENGINEER REGARDING ANY AND
ALL POWER SOURCES AND TIMING DEVICES NECESSARY TO MEET THE DESIGN INTENT. THESE ITEMS MUST BE INSTALLED
AS REQUIRED BY STATE AND LOCAL REGULATIONS. CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF LIGHTING
FIXTURES AND APPURTENANCES IN ACCORDANCE WITH ALL APPLICABLE BUILDING AND ELECTRICAL CODES.
7.THE CONTRACTOR MUST BRING IMMEDIATELY, IN WRITING, ANY LIGHT LOCATIONS THAT CONFLICT WITH DRAINAGE,
UTILITIES, OR OTHER STRUCTURE(S) TO THE ENGINEER OF RECORD'S ATTENTION, PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION.
8.THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT SHIELDING AND OR ROTATED OPTICS ARE INSTALLED AS INDICATED
ON THE PLAN IN ORDER TO ACHIEVE THE LIGHTING LEVELS THE REVIEWING AGENCY APPROVED.
SOIL EROSION & SEDIMENT CONTROL PLAN NOTES (Rev. 1/2020)
1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT
DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY
COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY
WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.
2.EROSION CONTROL MEASURES MUST CONFORM TO THE GUIDELINES FOR URBAN EROSION AND SEDIMENT
CONTROL UNLESS OTHERWISE NOTED, OR UNLESS ENGINEER CLEARLY AND SPECIFICALLY, IN WRITING, DIRECTS OTHERWISE.
INSTALLATION OF EROSION CONTROL, CLEARING, AND SITE WORK MUST BE PERFORMED EXACTLY AS INDICATED IN THE EROSION
CONTROL CONSTRUCTION NOTES.
3.THE DISTURBED LAND AREA OF THIS SITE IS APPROXIMATELY ACRES.
4.THE FOLLOWING EROSION CONTROL MEASURES ARE PROPOSED FOR THIS SITE:
A.STABILIZED CONSTRUCTION ENTRANCE/ EXIT - A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT IS TO BE INSTALLED
AT THE DESIGNATED LOCATION SHOWN ON THE PLAN. THIS AREA MUST BE GRADED SO THAT RUNOFF WATER WILL BE
RETAINED ON-SITE.
B.SEDIMENT FENCE - INSTALL SILT FENCE(S) AND/OR SILT SOCK AROUND ALL OF THE DOWNSLOPE PERIMETERS OF THE SITE,
TEMPORARY FILL AND SOIL STOCKPILES.
C.INSTALL FILTER FABRIC DROP INLET PROTECTION AROUND EACH DRAINAGE INLET AS DRAINAGE STRUCTURES ARE
INSTALLED TO REDUCE THE QUANTITY OF SEDIMENT. INSTALL TEMPORARY INLET PROTECTION ON INLETS DOWNSLOPE FROM
DISTURBANCE, WHICH MAY BE BEYOND THE LIMITS OF DISTURBED AREA.
5.INSTALLATION OF EROSION CONTROL DEVICES MUST BE IN ACCORDANCE WITH ALL OF THE MANUFACTURER'S
RECOMMENDATIONS.
6.THE CONTRACTOR MUST INSPECT EROSION CONTROL MEASURES WEEKLY. THE CONTRACTOR MUST REMOVE ANY SILT DEPOSITS
GREATER THAN COLLECTED ON THE FILTER FABRIC AND/OR SILT SOCK BARRIERS AND EXCAVATE AND REMOVE ANY SILT
FROM DROP INLET PROTECTION.
7.THE CONTRACTOR MUST APPLY TEMPORARY SEED AND MULCH TO ALL DISTURBED AREAS THAT WILL NOT BE BROUGHT TO
FINISHED GRADE AND VEGETATED WITHIN 7 DAYS. WHEN AREAS ARE DISTURBED AFTER THE GROWING SEASON, THE
CONTRACTOR MUST STABILIZE SAME WITH GEOTEXTILE FABRIC AND MAINTAIN SAME IN STRICT ACCORDANCE WITH BEST
MANAGEMENT PRACTICES.
8.THE CONTRACTOR MUST INSTALL ADDITIONAL EROSION CONTROL MEASURES IF ENGINEER SO REQUIRES, TO PREVENT ANY,
INCLUDING THE INCIDENTAL, DISCHARGE OF SILT-LADEN RUNOFF FROM EXITING THE SITE.
9.THE CONTRACTOR MUST BE RESPONSIBLE FOR INSPECTING AND MAINTAINING ALL EROSION CONTROL MEASURES ON THE SITE
UNTIL PERMANENT PAVING AND TURF/LANDSCAPING IS ESTABLISHED. THE COSTS OF INSTALLING AND MAINTAINING THE EROSION
CONTROL MEASURES MUST BE INCLUDED IN THE BID PRICE FOR THE SITE WORK AND THE CONTRACTOR IS RESPONSIBLE FOR
ALL SUCH COSTS.
10.THE CONTRACTOR MUST CONTINUE TO MAINTAIN ALL EROSION CONTROL MEASURES UNTIL THE COMPLETION OF CONSTRUCTION
AND THE ESTABLISHMENT OF VEGETATION.
11.THE CONTRACTOR MUST REMOVE EROSION CONTROL MEASURES, SILT AND DEBRIS AFTER ESTABLISHING PERMANENT
VEGETATION COVER OR OTHER INSTALLING A DIFFERENT, SPECIFIED METHOD OF STABILIZATION.
12.THIS PLAN REPRESENTS THE MINIMUM LEVEL OF IMPLEMENTATION OF TEMPORARY EROSION AND SEDIMENTATION CONTROL
FACILITIES, MEASURES AND STRUCTURES. ADDITIONAL FACILITIES, MEASURES AND STRUCTURES MUST BE INSTALLED WHERE
NECESSARY TO COMPLY WITH ALL APPLICABLE CODES AND STANDARDS AND/OR TO PREVENT ANY, INCLUDING THE INCIDENTAL
DISCHARGE OF SILT-LADEN RUNOFF FROM EXITING THE SITE.
13.THE CONTRACTOR MUST PROTECT ALL EXISTING TREES AND SHRUBS. THE CONTRACTOR MUST REFER TO THE LANDSCAPE
AND/OR DEMOLITION PLAN(S) FOR TREE PROTECTION, FENCE LOCATIONS AND DETAILS.
14.THE CONTRACTOR MUST REFER TO GRADING PLANS FOR ADDITIONAL INFORMATION.
15.THE CONTRACTOR MUST CLEAN EXISTING AND PROPOSED DRAINAGE STRUCTURES AND INTERCONNECTING PIPES ON OR
OFF-SITE AS THE JURISDICTIONAL AGENCY REQUIRES, BOTH AT THE TIME OF SITE STABILIZATION AND AT END OF PROJECT.
16.SOIL EROSION CONTROL MEASURES MUST BE ADJUSTED OR RELOCATED BY THE CONTRACTOR AS IDENTIFIED DURING SITE
OBSERVATION IN ORDER TO MAINTAIN THE COMPLETE EFFECTIVENESS OF ALL CONTROL MEASURES.
17.THE CONTRACTOR MUST IDENTIFY, ON THE PLAN, THE LOCATION OF WASTE CONTAINERS, FUEL STORAGE TANKS, CONCRETE
WASHOUT AREAS AND ANY OTHER LOCATIONS WHERE HAZARDOUS MATERIALS ARE STORED.
NORTH CAROLINA
16.98
6"
DRAINAGE AND UTILITY NOTES (Rev.1/2020)
1.THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT
DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY
COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY
WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES.
2.LOCATIONS OF ALL EXISTING AND PROPOSED SERVICES ARE APPROXIMATE, AND THE CONTRACTOR MUST INDEPENDENTLY
VERIFY AND CONFIRM THOSE LOCATIONS AND SERVICES WITH LOCAL UTILITY COMPANIES PRIOR TO COMMENCING ANY
CONSTRUCTION OR EXCAVATION. THE CONTRACTOR MUST INDEPENDENTLY VERIFY AND CONFIRM ALL SANITARY CONNECTION
POINTS AND ALL OTHER UTILITY SERVICE CONNECTION POINTS IN THE FIELD, PRIOR TO COMMENCING ANY CONSTRUCTION. THE
CONTRACTOR MUST REPORT ALL DISCREPANCIES, ERRORS AND OMISSIONS IN WRITING, TO THE ENGINEER OF RECORD.
3.THE CONTRACTOR MUST VERTICALLY AND HORIZONTALLY LOCATE ALL UTILITIES AND SERVICES INCLUDING, BUT NOT LIMITED
TO, GAS, WATER, ELECTRIC, SANITARY AND STORM, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN THE LIMITS OF
DISTURBANCE OR WORK SPACE, WHICHEVER IS GREATER. THE CONTRACTOR MUST USE, REFER TO, AND COMPLY WITH THE
REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL OF THE UNDERGROUND UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL DAMAGE TO ANY EXISTING UTILITIES WHICH OCCUR DURING
CONSTRUCTION, AT NO COST TO THE OWNER AND AT CONTRACTOR'S SOLE COST AND EXPENSE. THE CONTRACTOR MUST
BEAR ALL COSTS ASSOCIATED WITH DAMAGE TO ANY EXISTING UTILITIES WHICH OCCURS DURING CONSTRUCTION.
4.THE CONTRACTOR MUST FIELD VERIFY THE PROPOSED INTERFACE POINTS (CROSSINGS) WITH EXISTING UNDERGROUND
UTILITIES BY USING A TEST PIT TO CONFIRM EXACT DEPTH, PRIOR TO COMMENCEMENT OF CONSTRUCTION.
5.STORMWATER ROOF DRAIN LOCATIONS ARE BASED ON ARCHITECTURAL PLANS. THE CONTRACTOR IS RESPONSIBLE FOR
VERIFYING LOCATIONS OF SAME BASED UPON FINAL ARCHITECTURAL PLANS.
6.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING SITE PLAN DOCUMENTS AND ARCHITECTURAL PLANS FOR EXACT
BUILDING UTILITY CONNECTION LOCATIONS, GREASE TRAP REQUIREMENTS AND DETAILS, DOOR ACCESS, AND EXTERIOR
GRADING. THE ARCHITECT WILL DETERMINE THE UTILITY SERVICE SIZES. THE CONTRACTOR MUST COORDINATE INSTALLATION
OF UTILITY SERVICES WITH THE INDIVIDUAL COMPANIES, TO AVOID CONFLICTS AND TO ENSURE THAT PROPER DEPTHS ARE
ACHIEVED. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT INSTALLATION OF ALL IMPROVEMENTS COMPLIES WITH
ALL UTILITY REQUIREMENTS OF THE APPLICABLE JURISDICTION AND REGULATORY AGENCIES AND ALL OTHER APPLICABLE
REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES AND, FURTHER, IS RESPONSIBLE FOR COORDINATING THE
UTILITY TIE-INS/CONNECTIONS PRIOR TO CONNECTING TO THE EXISTING UTILITY/SERVICE. WHERE A CONFLICT(S) EXISTS
BETWEEN THESE DOCUMENTS AND THE ARCHITECTURAL PLANS, OR WHERE ARCHITECTURAL PLAN UTILITY CONNECTION
POINTS DIFFER, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, AND PRIOR TO
CONSTRUCTION, MUST RESOLVE SAME.
7.ALL FILL, COMPACTION, AND BACKFILL MATERIALS REQUIRED FOR UTILITY INSTALLATION MUST BE EXACTLY AS PER THE
RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT AND THE CONTRACTOR MUST COORDINATE SAME WITH THE
APPLICABLE UTILITY COMPANY SPECIFICATIONS. WHEN THE PROJECT DOES NOT HAVE GEOTECHNICAL RECOMMENDATIONS,
FILL AND COMPACTION MUST, AT A MINIMUM, COMPLY WITH THE STATE DOT REQUIREMENTS AND SPECIFICATIONS AND
CONSULTANT HAS NO LIABILITY OR RESPONSIBILITY FOR OR AS RELATED TO FILL, COMPACTION AND BACKFILL.
8.DURING THE INSTALLATION OF SANITARY, STORM, AND ALL UTILITIES, THE CONTRACTOR MUST MAINTAIN A
CONTEMPORANEOUS AND THOROUGH RECORD OF CONSTRUCTION TO IDENTIFY THE AS-INSTALLED LOCATIONS OF ALL
UNDERGROUND INFRASTRUCTURE. THE CONTRACTOR MUST CAREFULLY NOTE ANY INSTALLATIONS THAT DEVIATE, IN ANY
RESPECT, FROM THE INFORMATION CONTAINED IN THESE PLANS. THIS RECORD MUST BE KEPT ON A CLEAN COPY OF THE SITE
PLAN, WHICH THE CONTRACTOR MUST PROMPTLY PROVIDE TO THE OWNER IMMEDIATELY UPON THE COMPLETION OF WORK.
9.THE CONTRACTOR MUST ENSURE THAT ALL UTILITY TRENCHES LOCATED IN EXISTING PAVED ROADWAYS INCLUDING SANITARY,
WATER AND STORM SYSTEMS, ARE REPAIRED IN ACCORDANCE WITH REFERENCED MUNICIPAL, COUNTY AND OR STATE DOT
DETAILS AS APPLICABLE. THE CONTRACTOR MUST COORDINATE INSPECTION AND APPROVAL OF COMPLETED WORK WITH THE
AGENCY WITH JURISDICTION OVER SAME.
10.FINAL LOCATIONS OF PROPOSED UTILITY POLES, AND/ OR POLES TO BE RELOCATED ARE AT THE SOLE DISCRETION OF THE
RESPECTIVE UTILITY COMPANY, REGARDLESS OF WHAT THIS PLAN DEPICTS.
11.WATER SERVICE MATERIALS, BURIAL DEPTH, AND COVER REQUIREMENTS MUST BE SPECIFIED BY THE LOCAL UTILITY COMPANY.
THE CONTRACTOR MUST CONTACT THE APPLICABLE MUNICIPALITY TO CONFIRM THE PROPER WATER METER AND VAULT, PRIOR
TO COMMENCING CONSTRUCTION.
GENERAL NOTES (Rev. 1/2020)
1.THESE PLANS ARE SOLELY BASED ON INFORMATION THE OWNER AND OTHERS PROVIDED TO BOHLER ENGINEERING,
(HEREIN “BOHLER”) PRIOR TO THE DATE ON WHICH ENGINEER PREPARED THESE PLANS. THE CONTRACTOR MUST FIELD VERIFY ALL
EXISTING CONDITIONS AND IMMEDIATELY NOTIFY BOHLER , IN WRITING, IF ANY ACTUAL SITE CONDITIONS DIFFER FROM THOSE SHOWN
ON THESE PLANS, OR IF THE PROPOSED WORK CONFLICTS WITH ANY OTHER SITE FEATURES.
2.THE CONTRACTOR MUST STRICTLY COMPLY WITH THESE NOTES AND ALL SPECIFICATIONS/REPORTS CONTAINED HEREIN. THE
CONTRACTOR MUST ENSURE THAT ALL SUBCONTRACTORS FULLY AND COMPLETELY CONFORM TO AND COMPLY WITH THESE
REQUIREMENTS, THESE NOTES, AND THE REQUIREMENTS ARTICULATED IN THE NOTES CONTAINED IN ALL THE OTHER DRAWINGS THAT
COMPRISE THE PLAN SET OF DRAWINGS. ADDITIONAL NOTES AND SPECIFIC PLAN NOTES MAY BE FOUND ON THE INDIVIDUAL PLANS.
THESE GENERAL NOTES APPLY TO THIS ENTIRE DOCUMENT PACKAGE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL
CONSTRUCTION CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED
WITH THE PROJECT WORK SCOPE, PRIOR TO THE INITIATION AND COMMENCEMENT OF CONSTRUCTION.
3.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST CONFIRM WITH THE ENGINEER OF RECORD THAT THE
LATEST EDITION OF THE DOCUMENTS AND/OR REPORTS REFERENCED WITHIN THE PLAN REFERENCES ARE BEING USED FOR
CONSTRUCTION. THIS IS THE CONTRACTOR'S SOLE AND COMPLETE RESPONSIBILITY.
4.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST ENSURE THAT ALL REQUIRED PERMITS AND APPROVALS
HAVE BEEN OBTAINED. NO CONSTRUCTION OR FABRICATION IS TO BEGIN UNTIL THE CONTRACTOR HAS RECEIVED AND THOROUGHLY
REVIEWED THE CONDITIONS OF APPROVAL TO ALL PLANS AND OTHER DOCUMENTS REVIEWED AND APPROVED BY THE PERMITTING
AUTHORITIES AND HAS ALSO CONFIRMED THAT ALL NECESSARY AND REQUIRED PERMITS HAVE BEEN OBTAINED. THE CONTRACTOR
MUST HAVE COPIES OF ALL PERMITS AND APPROVALS ON SITE AT ALL TIMES.
5.THE CONTRACTOR MUST ENSURE THAT ALL WORK IS PERFORMED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS/REPORTS
AND CONDITIONS OF APPROVAL, AND ALL APPLICABLE REQUIREMENTS, RULES, REGULATIONS, STATUTORY REQUIREMENTS, CODES,
LAWS AND STANDARDS OF ALL GOVERNMENTAL ENTITIES WITH JURISDICTION OVER THIS PROJECT, AND ALL PROVISIONS IN AND
CONDITIONS OF THE CONSTRUCTION CONTRACT WITH THE OWNER/DEVELOPER INCLUDING ALL EXHIBITS, ATTACHMENTS AND
ADDENDA TO SAME.
6.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST COORDINATE THE BUILDING LAYOUT BY CAREFULLY
REVIEWING THE MOST CURRENT ARCHITECTURAL, CIVIL AND STRUCTURAL CONSTRUCTION DOCUMENTS (INCLUDING, BUT NOT LIMITED
TO, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION PLANS, WHERE APPLICABLE). THE CONTRACTOR MUST
IMMEDIATELY NOTIFY OWNER, ARCHITECT AND ENGINEER OF RECORD, IN WRITING, OF ANY CONFLICTS, DISCREPANCIES OR
AMBIGUITIES WHICH EXIST BETWEEN THESE PLANS AND ANY OTHER PLANS THAT COMPRISE THE CONSTRUCTION DOCUMENTS.
7.CONTRACTOR MUST REFER TO AND ENSURE COMPLIANCE WITH THE APPROVED ARCHITECTURAL/BUILDING PLANS OF RECORD FOR
EXACT LOCATIONS AND DIMENSIONS OF ENTRY/EXIT POINTS, ELEVATIONS, PRECISE BUILDING DIMENSIONS, AND EXACT BUILDING
UTILITY LOCATIONS.
8.THE CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS SHOWN ON THESE PLANS, PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR MUST IMMEDIATELY NOTIFY ENGINEER OF RECORD, IN WRITING, IF ANY
CONFLICTS, DISCREPANCIES, OR AMBIGUITIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION. NO EXTRA COMPENSATION WILL
BE PAID TO THE CONTRACTOR FOR WORK WHICH HAS TO BE RE-DONE OR REPAIRED DUE TO DIMENSIONS, MEASUREMENTS OR
GRADES SHOWN INCORRECTLY ON THESE PLANS PRIOR TO BOTH (A) THE CONTRACTOR GIVING ENGINEER OF RECORD WRITTEN
NOTIFICATION OF SAME AND (B) ENGINEER OF RECORD, THEREAFTER, PROVIDING THE CONTRACTOR WITH WRITTEN AUTHORIZATION
TO PROCEED WITH SUCH ADDITIONAL WORK.
9.THE CONTRACTOR MUST VERIFY ALL DIMENSIONS AND MEASUREMENTS INCLUDED ON DESIGN DOCUMENTS HEREIN AND MUST NOT
SCALE OFF THE DRAWINGS DUE TO POTENTIAL PRINTING INACCURACIES. ALL DIMENSIONS AND MEASUREMENTS ARE TO BE CHECKED
AND CONFIRMED BY THE GENERAL CONTRACTOR PRIOR TO PREPARATION OF SHOP DRAWINGS, FABRICATION/ORDERING OF PARTS
AND MATERIALS AND COMMENCEMENT OF SITE WORK. SITE PLAN DRAWINGS ARE NOT INTENDED AS SURVEY DOCUMENTS.
DIMENSIONS SUPERSEDE GRAPHICAL REPRESENTATIONS. THE CONTRACTOR MUST MAKE CONTRACTOR'S OWN MEASUREMENTS FOR
LAYOUT OF IMPROVEMENTS.
10.THE OWNER AND CONTRACTOR MUST BE FAMILIAR WITH, AND RESPONSIBLE FOR THE PROCUREMENT OF ANY AND ALL
CERTIFICATIONS REQUIRED FOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
11.WHEN INCLUDED AS ONE OF THE REFERENCED DOCUMENTS, THE GEOTECHNICAL REPORT, SPECIFICATIONS AND RECOMMENDATIONS
SET FORTH THEREIN ARE A PART OF THE REQUIRED CONSTRUCTION DOCUMENTS AND, IN CASE OF CONFLICT, DISCREPANCY OR
AMBIGUITY, THE MORE STRINGENT REQUIREMENTS AND/OR RECOMMENDATIONS CONTAINED IN: (A) THE PLANS; AND (B) THE
GEOTECHNICAL REPORT AND RECOMMENDATIONS, MUST TAKE PRECEDENCE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE
PLANS. THE CONTRACTOR MUST NOTIFY THE ENGINEER OF RECORD, IN WRITING, OF ANY SUCH CONFLICT, DISCREPANCY OR
AMBIGUITY BETWEEN THE GEOTECHNICAL REPORT AND PLANS AND SPECIFICATIONS, PRIOR TO PROCEEDING WITH ANY FURTHER
WORK. IF A GEOTECHNICAL REPORT WAS NOT CREATED, THEN THE CONTRACTOR MUST FOLLOW AND COMPLY WITH ALL OF THE
REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS AND APPLICABLE SPECIFICATIONS WHICH HAVE
JURISDICTION OVER THIS PROJECT.
12.ENGINEER OF RECORD IS NEITHER LIABLE NOR RESPONSIBLE FOR ANY SUBSURFACE CONDITIONS AND FURTHER, HAS NO LIABILITY
FOR ANY HAZARDOUS MATERIALS, HAZARDOUS SUBSTANCES, OR POLLUTANTS ON, ABOUT OR UNDER THE PROPERTY.
13.THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING WHEN AND WHERE SHORING IS REQUIRED AND FOR INSTALLING ALL SHORING
REQUIRED DURING EXCAVATION (TO BE PERFORMED IN ACCORDANCE WITH CURRENT OSHA STANDARDS) AND ANY ADDITIONAL
PRECAUTIONS TO BE TAKEN TO ASSURE THE STABILITY OF ADJACENT, NEARBY AND CONTIGUOUS STRUCTURES AND PROPERTIES. ALL
OF THIS WORK IS TO BE PERFORMED AT CONTRACTOR'S SOLE COST AND EXPENSE.
14.THE CONTRACTOR MUST EXERCISE EXTREME CAUTION WHEN PERFORMING ANY WORK ACTIVITIES ADJACENT TO PAVEMENT,
STRUCTURES, ETC. WHICH ARE TO REMAIN EITHER FOR AN INITIAL PHASE OF THE PROJECT OR AS PART OF THE FINAL CONDITION. THE
CONTRACTOR IS RESPONSIBLE FOR TAKING ALL APPROPRIATE MEASURES REQUIRED TO ENSURE THE STRUCTURAL STABILITY OF
SIDEWALKS AND PAVEMENT, UTILITIES, BUILDINGS, AND INFRASTRUCTURE WHICH ARE TO REMAIN, AND TO PROVIDE A SAFE WORK
AREA FOR THIRD PARTIES, PEDESTRIANS AND ANYONE INVOLVED WITH THE PROJECT.
15.DEBRIS MUST NOT BE BURIED ON THE SUBJECT SITE. ALL DEMOLITION AND CONSTRUCTION WASTES, UNSUITABLE EXCAVATED
MATERIAL, EXCESS SOIL AND DEBRIS (SOLID WASTE) MUST BE DISPOSED OF IN ACCORDANCE WITH THE REQUIREMENTS OF ANY AND
ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS AND APPLICABLE CODES WHICH HAVE JURISDICTION OVER THIS PROJECT OR
OVER THE CONTRACTOR.
16.IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO MAINTAIN RECORDS TO DEMONSTRATE PROPER AND FULLY COMPLIANT DISPOSAL
ACTIVITIES, TO BE PROMPTLY PROVIDED TO THE OWNER UPON REQUEST.
17.THE CONTRACTOR MUST REPAIR, AT CONTRACTOR'S SOLE COST, ALL DAMAGE DONE TO ANY NEW OR EXISTING CONSTRUCTION OR
PROPERTY DURING THE COURSE OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO DRAINAGE, UTILITIES, PAVEMENT, STRIPING,
CURB, ETC. AND MUST BEAR ALL COSTS ASSOCIATED WITH SAME TO INCLUDE, BUT NOT BE LIMITED TO, REDESIGN, RE-SURVEY,
RE-PERMITTING AND CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR AND MUST REPLACE ALL SIGNAL INTERCONNECTION
CABLE, WIRING CONDUITS, AND ANY UNDERGROUND ACCESSORY EQUIPMENT DAMAGED DURING CONSTRUCTION AND MUST BEAR ALL
COSTS ASSOCIATED WITH SAME. THE REPAIR OF ANY SUCH NEW OR EXISTING CONSTRUCTION OR PROPERTY MUST RESTORE SUCH
CONSTRUCTION OR PROPERTY TO A CONDITION EQUIVALENT TO OR BETTER THAN THE CONDITIONS PRIOR TO COMMENCEMENT OF
THE CONSTRUCTION, AND IN CONFORMANCE WITH APPLICABLE CODES, LAWS, RULES, REGULATIONS, STATUTORY REQUIREMENTS
AND STATUTES. THE CONTRACTOR MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE CONTRACTOR MUST, PROMPTLY, DOCUMENT
ALL EXISTING DAMAGE AND NOTIFY, IN WRITING, THE OWNER AND THE CONSTRUCTION MANAGER PRIOR TO THE START OF
CONSTRUCTION.
18.THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR AND HAVE NO CONTRACTUAL, LEGAL OR OTHER
RESPONSIBILITIES FOR JOB SITE SAFETY JOB SITE SUPERVISION, OR ANYTHING RELATED TO SAME. THE ENGINEER OF RECORD AND
BOHLER HAVE NOT BEEN RETAINED TO PERFORM OR TO BE RESPONSIBLE FOR JOB SITE SAFETY, SAME BEING WHOLLY OUTSIDE OF
ENGINEER OF RECORD'S AND BOHLER SERVICES AS RELATED TO THE PROJECT. THE ENGINEER OF RECORD AND BOHLER ARE NOT
RESPONSIBLE TO IDENTIFY OR REPORT ANY JOB SITE SAFETY ISSUES OR ANY JOB SITE CONDITIONS, AT ANY TIME.
19.THE CONTRACTOR MUST IMMEDIATELY IDENTIFY IN WRITING, TO THE ENGINEER OF RECORD AND BOHLER , ANY DISCREPANCIES THAT
MAY OR COULD AFFECT THE PUBLIC SAFETY, HEALTH OR GENERAL WELFARE, OR PROJECT COST. IF THE CONTRACTOR PROCEEDS
WITH CONSTRUCTION WITHOUT PROVIDING PROPER WRITTEN NOTIFICATION AS DESCRIBED ABOVE, IT WILL BE AT THE CONTRACTOR'S
OWN RISK AND, FURTHER, THE CONTRACTOR MUST INDEMNIFY, DEFEND AND HOLD HARMLESS THE ENGINEER OF RECORD AND
BOHLER FOR ANY AND ALL DAMAGES, COSTS, INJURIES, ATTORNEY'S FEES AND THE LIKE WHICH RESULT FROM OR ARE IN ANY WAY
RELATED TO SAME INCLUDING, BUT NOT LIMITED TO, ANY THIRD PARTY AND FIRST PARTY CLAIMS.
20.THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR ANY INJURY OR DAMAGES RESULTING FROM THE
CONTRACTOR'S FAILURE TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH THE APPROVED PLANS, AND CURRENT CODES,
RULES, STATUTES AND THE LIKE. IF THE CONTRACTOR AND/OR OWNER FAIL TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH
APPROVED PLANS, RULES, STATUTES, CODES AND THE LIKE, THE CONTRACTOR AND/OR OWNER AGREE TO AND MUST JOINTLY,
INDEPENDENTLY, SEPARATELY, AND SEVERALLY INDEMNIFY AND HOLD THE ENGINEER OF RECORD AND BOHLER HARMLESS FOR AND
FROM ALL INJURIES, CLAIMS AND DAMAGES THAT ENGINEER AND BOHLER SUFFER AND ANY AND ALL COSTS THAT ENGINEER AND
BOHLER INCUR AS RELATED TO SAME.
21.ALL CONTRACTORS MUST CARRY AT LEAST THE MINIMUM AMOUNT OF THE SPECIFIED AND COMMERCIALLY REASONABLE STATUTORY
WORKER'S COMPENSATION INSURANCE, EMPLOYER'S LIABILITY INSURANCE AND COMMERCIAL GENERAL LIABILITY INSURANCE (CGL)
INCLUDING ALSO ALL UMBRELLA COVERAGES. ALL CONTRACTORS MUST HAVE THEIR CGL POLICIES ENDORSED TO NAME BOHLER ,
AND ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS,
COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS
AND SUBCONSULTANTS AS ADDITIONAL NAMED INSUREDS AND TO PROVIDE CONTRACTUAL LIABILITY COVERAGE SUFFICIENT TO
INSURE THE (DEFEND, IF APPLICABLE) AND HOLD HARMLESS AND INDEMNITY OBLIGATIONS ASSUMED AND AGREED TO BY THE
CONTRACTOR HEREIN. ALL CONTRACTORS MUST FURNISH BOHLER WITH CERTIFICATIONS OF INSURANCE OR CERTIFICATES OF
INSURANCE AS EVIDENCE OF THE REQUIRED INSURANCE COVERAGES PRIOR TO COMMENCING ANY WORK AND UPON RENEWAL OF
EACH POLICY DURING THE ENTIRE PERIOD OF CONSTRUCTION AND FOR TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION AND
AFTER ALL PERMITS ARE ISSUED, WHICHEVER DATE IS LATER. IN ADDITION, ALL CONTRACTORS AGREE THAT THEY WILL, TO THE
FULLEST EXTENT PERMITTED UNDER THE LAW, INDEMNIFY, DEFEND AND HOLD HARMLESS BOHLER AND ITS PAST, PRESENT AND
FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS,
SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS
FROM AND AGAINST ANY DAMAGES, INJURIES, CLAIMS, ACTIONS, PENALTIES, EXPENSES, PUNITIVE DAMAGES, TORT DAMAGES,
STATUTORY CLAIMS, STATUTORY CAUSES OF ACTION, LOSSES, CAUSES OF ACTION, LIABILITIES OR COSTS, INCLUDING, BUT NOT
LIMITED TO, REASONABLE ATTORNEYS' FEES AND DEFENSE COSTS, ARISING OUT OF OR IN ANY WAY CONNECTED WITH OR TO THE
PROJECT, INCLUDING ALL CLAIMS BY EMPLOYEES OF THE CONTRACTOR(S), ALL CLAIMS BY THIRD PARTIES AND ALL CLAIMS RELATED
TO THE PROJECT. THE CONTRACTOR MUST NOTIFY ENGINEER, IN WRITING, AT LEAST THIRTY (30) DAYS PRIOR TO ANY TERMINATION,
SUSPENSION OR CHANGE OF ITS INSURANCE HEREUNDER.
22.THE ENGINEER OF RECORD AND BOHLER ARE NOT RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHNIQUES OR
PROCEDURES, GENERALLY OR FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES OR PROCEDURES FOR COMPLETION OF THE
WORK DEPICTED BOTH ON THESE PLANS, AND FOR ANY CONFLICTS IN SCOPE AND REVISIONS THAT RESULT FROM SAME. THE
CONTRACTOR IS FULLY AND SOLELY RESPONSIBLE FOR DETERMINING THE MEANS AND METHODS FOR COMPLETION OF THE WORK,
PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
23.NEITHER THE PROFESSIONAL ACTIVITIES OF: BOHLER , NOR THE PRESENCE OF BOHLER AND/OR ITS PAST, PRESENT AND FUTURE
OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS,
EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AT A
CONSTRUCTION/PROJECT SITE (HEREIN “BOHLER PARTIES”), RELIEVES OR WILL RELIEVE THE CONTRACTOR OF AND FROM ITS
OBLIGATIONS, DUTIES AND RESPONSIBILITIES INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION MEANS, METHODS, SEQUENCE,
TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, OVERSEEING, SUPERINTENDING AND COORDINATING THE WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS AND COMPLIANCE WITH ALL HEALTH AND SAFETY PRECAUTIONS REQUIRED BY ANY
REGULATORY AGENCIES WITH JURISDICTION OVER THE PROJECT AND/OR PROPERTY. BOHLER AND ITS EMPLOYEES, PERSONNEL,
AGENTS, SUBCONTRACTORS AND SUBCONSULTANTS HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER (OR ANY
RESPONSIBILITY FOR) ANY CONSTRUCTION, THE CONTRACTOR OR ITS EMPLOYEES RELATING TO THEIR WORK AND ANY AND ALL
HEALTH AND SAFETY PROGRAMS OR PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY. THE
CONTRACTOR MUST INDEMNIFY, DEFEND, PROTECT AND HOLD HARMLESS BOHLER FOR AND FROM ANY LIABILITY TO BOHLER
RESULTING FROM THE CONTRACTOR'S WORK, SERVICES AND/OR VIOLATIONS OF THIS NOTE, THESE NOTES OR ANY NOTES IN THE
PLAN SET AND, FURTHER, THE CONTRACTOR MUST NAME BOHLER AS AN ADDITIONAL INSURED UNDER THE GENERAL CONTRACTOR'S
POLICIES OF GENERAL LIABILITY INSURANCE AS DESCRIBED ABOVE.
24.WHEN IT IS CLEARLY AND SPECIFICALLY WITHIN BOHLER'S SCOPE OF SERVICES CONTRACT WITH THE OWNER/DEVELOPER, BOHLER
WILL REVIEW OR TAKE OTHER APPROPRIATE ACTION ON THE CONTRACTOR SUBMITTALS, SUCH AS SHOP DRAWINGS, PRODUCT DATA,
SAMPLES, AND OTHER DATA, WHICH THE CONTRACTOR IS REQUIRED TO SUBMIT, BUT ONLY FOR THE LIMITED PURPOSE OF
EVALUATING CONFORMANCE WITH THE DESIGN INTENT AND THE INFORMATION SHOWN IN THE CONSTRUCTION CONTRACT
DOCUMENTS. CONSTRUCTION MEANS AND METHODS AND/OR TECHNIQUES OR PROCEDURES, COORDINATION OF THE WORK WITH
OTHER TRADES, AND CONSTRUCTION SAFETY PRECAUTIONS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND BOHLER HAS
NO RESPONSIBILITY OR LIABILITY FOR SAME. BOHLER WILL PERFORM ITS SHOP DRAWING REVIEW WITH REASONABLE PROMPTNESS,
AS CONDITIONS PERMIT. ANY DOCUMENT, DOCUMENTING BOHLER'S REVIEW OF A SPECIFIC ITEM OR LIMITED SCOPE, MUST NOT
INDICATE THAT BOHLER HAS REVIEWED THE ENTIRE ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. BOHLER IS NOT RESPONSIBLE
FOR ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR MUST, IN WRITING, PROMPTLY AND IMMEDIATELY
BRING ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS TO BOHLER'S ATTENTION. BOHLER IS NOT REQUIRED TO REVIEW
PARTIAL SUBMISSIONS OR THOSE FOR WHICH SUBMISSIONS OF CORRELATED ITEMS HAVE NOT BEEN RECEIVED.
25.IF THE CONTRACTOR DEVIATES FROM THESE PLANS AND/OR SPECIFICATIONS, INCLUDING THE NOTES CONTAINED HEREIN, WITHOUT
FIRST OBTAINING THE PRIOR WRITTEN AUTHORIZATION OF THE ENGINEER OF RECORD AND/OR BOHLER FOR ALL DEVIATIONS WITHIN
ENGINEER'S SCOPE, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PAYMENT OF ALL COSTS INCURRED IN CORRECTING ANY
WORK PERFORMED WHICH DEVIATES FROM THE PLANS, ALL FINES AND/OR PENALTIES ASSESSED WITH RESPECT THERETO AND ALL
COMPENSATORY OR PUNITIVE DAMAGES RESULTING THEREFROM AND, FURTHER, MUST DEFEND, INDEMNIFY, PROTECT, AND HOLD
HARMLESS THE ENGINEER OF RECORD AND BOHLER PARTIES TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, FOR AND FROM
ALL FEES, ATTORNEYS' FEES, DAMAGES, COSTS, JUDGMENTS, CLAIMS, INJURIES, PENALTIES AND THE LIKE RELATED TO SAME.
26.THE CONTRACTOR IS RESPONSIBLE FOR A MAINTAINING AND PROTECTING THE TRAFFIC CONTROL PLAN AND ELEMENTS IN
ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS, FOR ALL WORK THAT AFFECTS PUBLIC TRAVEL EITHER IN THE
RIGHT OF WAY OR ON SITE. THE COST FOR THIS ITEM MUST BE INCLUDED IN THE CONTRACTOR'S PRICE AND IS THE CONTRACTOR'S
SOLE RESPONSIBILITY.
27.OWNER MUST MAINTAIN AND PRESERVE ALL PHYSICAL SITE FEATURES AND DESIGN FEATURES DEPICTED ON THE PLANS AND
RELATED DOCUMENTS IN STRICT ACCORDANCE WITH THE APPROVED PLAN(S) AND DESIGN; AND, FURTHER, THE ENGINEER OF
RECORD AND/OR BOHLER ARE NOT RESPONSIBLE FOR ANY FAILURE TO SO MAINTAIN OR PRESERVE SITE AND/OR DESIGN FEATURES.
IF OWNER FAILS TO MAINTAIN AND/OR PRESERVE ALL PHYSICAL SITE FEATURES AND/OR DESIGN FEATURES DEPICTED ON THE PLANS
AND RELATED DOCUMENTS, OWNER AGREES TO INDEMNIFY AND HOLD THE ENGINEER OF RECORD AND BOHLER PARTIES, HARMLESS
FOR ALL INJURIES, DAMAGES AND COSTS THAT ENGINEER OF RECORD AND/OR BOHLER INCUR AS A RESULT OF SAID FAILURE OR
FAILURE TO PRESERVE.
28.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ENSURING THAT ALL CONSTRUCTION ACTIVITIES AND MATERIALS COMPLY WITH AND
CONFORM TO APPLICABLE FEDERAL, STATE AND LOCAL RULES AND REGULATIONS, LAWS, ORDINANCES, AND CODES, AND ALL
APPLICABLE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.) AS AMENDED, AND ANY
MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
29.THE CONTRACTOR MUST STRICTLY COMPLY WITH THE LATEST AND CURRENT OSHA STANDARDS AND REGULATIONS, AND/OR ANY
OTHER AGENCY WITH JURISDICTION OVER EXCAVATION AND TRENCHING PROCEDURES. ENGINEER OF RECORD AND BOHLER HAS NO
RESPONSIBILITY FOR OR AS RELATED TO EXCAVATION AND TRENCHING PROCEDURES AND WORK.
30.THE CONTRACTOR AND THE OWNER MUST INSTALL ALL ELEMENTS AND COMPONENTS IN STRICT COMPLIANCE WITH AND IN
ACCORDANCE WITH MANUFACTURER'S STANDARDS AND RECOMMENDED INSTALLATION CRITERIA AND SPECIFICATIONS. IF THE
CONTRACTOR AND/OR OWNER FAIL TO DO SO, THEY AGREE TO JOINTLY, INDEPENDENTLY, SEPARATELY, COLLECTIVELY, AND
SEVERALLY INDEMNIFY, DEFEND, PROTECT AND HOLD ENGINEER OF RECORD AND/OR BOHLER PARTIES HARMLESS FOR ALL INJURIES
AND DAMAGES THAT ENGINEER SUFFERS AND COSTS THAT ENGINEER INCURS AS A RESULT OF SAID FAILURE.
31.THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN AN ON-SITE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) IN COMPLIANCE
WITH THE ENVIRONMENTAL PROTECTION AGENCY (EPA) REQUIREMENTS OR LOCAL GOVERNING AGENCY FOR SITES WHERE ONE (1)
ACRE OR MORE IS DISTURBED BY CONSTRUCTION ACTIVITIES (UNLESS THE LOCAL JURISDICTION REQUIRES A DIFFERENT
THRESHOLD). THE CONTRACTOR MUST ENSURE THAT ALL ACTIVITIES, INCLUDING THOSE OF ALL SUBCONTRACTORS, ARE IN
COMPLIANCE WITH THE SWPPP, INCLUDING BUT NOT LIMITED TO LOGGING ACTIVITIES (MINIMUM ONCE PER WEEK AND AFTER RAINFALL
EVENTS) AND CORRECTIVE MEASURES, AS APPROPRIATE AND FURTHER, THE CONTRACTOR IS SOLELY AND COMPLETELY
RESPONSIBLE FOR FAILING TO DO SO.
32.AS CONTAINED IN THESE DRAWINGS AND ASSOCIATED DOCUMENTS PREPARED BY THE SIGNATORY PROFESSIONAL ENGINEER OF
RECORD, THE USE OF THE WORDS 'CERTIFY' OR 'CERTIFICATION' CONSTITUTE(S) AN EXPRESSION ONLY OF PROFESSIONAL OPINION
REGARDING THE INFORMATION WHICH IS THE SUBJECT OF THE ENGINEER OF RECORD'S KNOWLEDGE OR BELIEF AND IN ACCORDANCE
WITH COMMON AND ACCEPTED PROCEDURE CONSISTENT WITH THE APPLICABLE STANDARDS OF PRACTICE, AND DOES NOT
CONSTITUTE A WARRANTY OR GUARANTEE OF ANY NATURE OR TYPE, EITHER EXPRESSED OR IMPLIED, UNDER ANY CIRCUMSTANCES.
NC, PLLC.
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-102 GENERAL NOTESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-102
GENERAL
NOTES
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-103 DEVELOPER'S REQUIRMENTS & GENERAL NOTESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-103
DEVELOPER'S
REQUIRMENTS
& GENERAL
NOTES
DEVELOPER'S REQUIREMENTS AND GENERAL NOTES
1.LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES ARE SHOWN ACCORDING
TO THE BEST INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. THE CONTRACTOR SHALL VERIFY THE
LOCATIONS, ELEVATIONS, AND DIMENSIONS OF ALL EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES, AFFECTING THIS
WORK, PRIOR TO CONSTRUCTION.
2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYOUT OF ALL WORK AS ILLUSTRATED ON PLANS. IF EXISTING CONDITIONS
DIFFER FROM THOSE ILLUSTRATED ON PLANS, NOTIFY OWNER AND PROJECT ENGINEER PRIOR TO CONSTRUCTION.
3.VERIFY ALL DIMENSIONS AND GRADES AT THE JOB SITE. IF DIFFERENCES ARE FOUND, NOTIFY OWNER AND PROJECT ENGINEER SO
THAT MODIFICATIONS TO THESE DRAWINGS CAN BE MADE.
4.PRIOR TO THE INITIATION OF SITE CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ANY EXISTING UTILITIES INCLUDING GAS,
WATER, ELECTRIC, COMMUNICATIONS, CABLE TELEVISION, SANITARY AND STORM SEWERS, ON AND/OR ADJACENT TO THE SITE.
REMOVE OR CAP SERVICES AS NECESSARY, COORDINATE WITH THE APPROPRIATE SERVICE PROVIDER.
5.THE GRAPHIC INFORMATION DEPICTED ON THESE PLANS HAS BEEN COMPLIED TO PROPORTION BY SCALE AS ACCURATELY AS
POSSIBLE. HOWEVER, DUE TO REPRODUCTIVE DISTORTION, REDUCTION, AND/OR REVISIONS, INFORMATION CONTAINED HEREIN IS
NOT INTENDED TO BE SCALED FOR CONSTRUCTION PURPOSES.
6.ALL SPECIFICATION AND DOCUMENTS REFERENCED HERE IN SHALL BE OF THE LATEST REVISION.
7.THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN AREAS OF BURIED UTILITIES AND SHALL ARRANGE FOR FIELD
LOCATIONS OF BURIED UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL ILLUSTRATED KNOWN
UNDERGROUND ELEMENTS. ADDITIONALLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR EXERCISING REASONABLE EFFORTS
TO PROTECT ANY UNKNOWN UNDERGROUND ELEMENTS. THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER AND OWNER
IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO THE ILLUSTRATED DESIGN.
8.THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING AT HIS EXPENSE ANY DAMAGE TO EXISTING FACILITIES, OR ANY OTHER
DAMAGES, ABOVE OR BELOW GROUND, THAT MAY OCCUR AS A RESULT OF THE WORK PERFORMED, BY THE CONTRACTOR OR
SUB-CONTRACTOR, AS CALLED FOR IN THESE CONSTRUCTION DOCUMENTS.
9.CONTACTOR TO COORDINATE WITH THE APPLICABLE ELECTRIC UTILITY SUPPLIER REGARDING ANY NECESSARY RELOCATION(S)
OF UNDERGROUND AND/OR OVERHEAD ELECTRIC FACILITIES AND FOR THE LOCATION AND INSTALLATION OF TRANSFORMER
PAD(S) AND ASSOCIATED ELECTRIC FACILITIES
10.IT IS THE CONTRACTOR'S RESPONSIBILITY TO BECOME FAMILIAR WITH THE PERMIT AND INSPECTION REQUIREMENTS SPECIFIED
BY THE VARIOUS GOVERNMENTAL AGENCIES AND THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO
CONSTRUCTION AND SCHEDULE INSPECTIONS ACCORDING TO AGENCY INSPECTIONS / REQUIREMENTS. IN ADDITION,
CONTRACTOR IS TO COMPLY WITH ALL CONDITIONS AND REQUIREMENTS AS IDENTIFIED IN ALL PERMITS AND APPROVALS FOR ALL
GOVERNING AGENCIES.
11.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ON ALL PRECAST AND MANUFACTURED ITEMS TO THE PROJECT ENGINEER
FOR APPROVAL. FAILURE TO OBTAIN APPROVAL BEFORE INSTALLATION MAY RESULT IN REMOVAL AND REPLACEMENT AT THE
CONTRACTOR'S EXPENSE.
12.CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION ADJUSTMENTS OF ALL EXISTING VAULTS (REGARDLESS OF FUNCTION),
METER BOXES, FIRE HYDRANTS, CLEAN OUTS, MANHOLES ETC. TO MATCH FINISHED GRADES. ALL SUCH WORK SHALL BE
COORDINATED WITH THE PROJECT ENGINEER.
13.ALL UTILITIES OR STRUCTURES NOT DESIGNATED FOR REMOVAL OR MODIFICATION ARE TO REMAIN AND BE PROTECTED FROM
DAMAGE.
14.ALL UNDERGROUND UTILITIES MUST BE IN-PLACE, TESTED AND INSPECTED PRIOR TO BASE AND SURFACE CONSTRUCTION.
15.PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC AND ALL OF THE OWNER'S FACILITIES SHOULD DAMAGES OCCUR,
CONTRACTOR SHALL REPAIR IMMEDIATELY AS DIRECTED BY THE OWNER OR PROJECT ENGINEER.
16.CONTRACTOR SHALL HOLD HARMLESS THE OWNER AND THE PROJECT ENGINEER FOR DAMAGES INJURIES OR OTHER ACCIDENTS
WHICH OCCUR DURING THESE CONSTRUCTION ACTIVITIES.
17.ALL ELEVATIONS ARE IN REFERENCE TO DESIGNATED BENCHMARKS.
18.CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATION OF ALL ILLUSTRATED CONSTRUCTION ACTIVITIES
AT THE JOB SITE.
19.THE CONTRACTOR SHALL COORDINATE WITH THE OWNER AND ADJACENT PROPERTY OWNERS AS REQUIRED FOR WORK OUTSIDE
OF PROPERTY LINES.
20.ANY NOTE OR REFERENCE TO ANY ELEMENT WHICH DOES NOT SPECIFY ACTION BY THE CONTRACTOR SHALL BE CONSTRUED AS
INFORMATION ONLY.
21.ALL STRUCTURES / UTILITIES DESIGNATED FOR MODIFICATION SHALL BE PROTECTED BY THE CONTRACTOR DURING
CONSTRUCTION.
22.WORK PERFORMED UNDER THIS CONTRACT SHALL INTERFACE SMOOTHLY WITH ANY OTHER WORK BEING PERFORMED ON SITE
BY OTHER CONTRACTORS/SUBCONTRACTORS AND UTILITY COMPANIES. IT WILL BE NECESSARY FOR THE GENERAL CONTACTOR
TO COORDINATE AND SCHEDULE HIS/HER ACTIVITIES ACCORDINGLY.
23.UPON COMPLETION OF CONSTRUCTION, THE CONTRACTOR SHALL FURNISH THE OWNER'S ENGINEER WITH COMPLETE “AS-BUILT”
INFORMATION, WHICH SHALL INCLUDE INVERT ELEVATIONS, LOCATIONS OF STRUCTURES FOR ALL UTILITIES INSTALLED, AS WELL
AS GRADE BREAK LOCATIONS AND ELEVATIONS OF THE CONSTRUCTION, AND AS OTHERWISE REQUIRED BY THE PROJECT
ENGINEER FOR ALL REQUIRED CERTIFICATIONS. THE AS-BUILT INFORMATION SHALL BE A SURVEY PREPARED BY A CERTIFIED AND
LICENSED LAND SURVEYOR
24.SEEDBED PREPARATION FOR ALL AREAS TO RECEIVE SEED:
a.CHISEL ANY COMPACTED AREAS AND SPREAD EXISTING STOCK PILE TOPSOIL IN AREAS SPECIFIED AS LAWN.
b.DISC ALL AREAS TO RECEIVE GRASS TO A MINIMUM OF 8 INCHES.
c.REMOVE ALL LOOSE ROCK, GRAVEL, ROOTS, DEBRIS AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH
AND UNIFORM
d.APPLY AGRICULTURAL LIME, FERTILIZER AND PHOSPHATE UNIFORMLY AS PER SPECIFICATIONS AND MIX WELL WITH SOIL.
e.CONTINUE TILLAGE UNTIL A WELL-PULVERIZED, FIRM, REASONABLE UNIFORM SEEDBED IS PREPARED TO A 6 INCHES DEPTH
f.SEED AT RATE SPECIFIED ON LANDSCAPE PLAN. SEED RATE IS TO BE SUFFICIENT TO PROVIDE A THICK, DENSE LAWN.
CONTRACTOR SHALL ACHIEVE AND MAINTAIN MINIMUM OF 90% COVERAGE PRIOR TO FINAL ACCEPTANCE AND SHALL PROVIDE
A THICK, DENSE LAWN. CONTRACTOR TO PREPARE THE SEEDBED AND RESEED AS APPROPRIATE UNTIL MINIMUM COVERAGE IS
OBTAINED.
g.SLOPE EROSION CONTROL MATTING SHALL BE INSTALLED FOR TEMPORARY STABILIZATION DURING THE ESTABLISHMENT OF
VEGETATIVE COVER ON ALL STEEP SLOPES (6:1 OR STEEPER)
h.MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. BEGIN THOROUGH WATERING OF GRASS AREAS IMMEDIATELY
UPON INSTALLATION. DO NOT ALLOW GRASSED AREAS TO BECOME EXCESSIVELY DRY.
i.INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITH THE PLANTING SEASON, IF POSSIBLE. IF
STAND SHOULD BE OVER 30% DAMAGED OR NOT ESTABLISHED, REESTABLISH FOLLOWING THE ORIGINAL LIME, FERTILIZER AND
SEEDING RATES AS SPECIFIED ON THE LANDSCAPE PLAN.
j.CONTRACTOR IS RESPONSIBLE FOR ALL GROUND COVER, INCLUDING MOWING, UNTIL ACCEPTANCE BY OWNER. DO NOT ALLOW
GROUND COVER TO GROW OVER 12” IN HEIGHT BEFORE MOWING.
25.SAFETY
a.DURING THE CONSTRUCTION AND/OR MAINTENANCE OF THIS PROJECT ALL SAFETY REGULATIONS ARE TO BE ENFORCED. THE
CONTRACTOR OR HIS REPRESENTATIVE SHALL BE RESPONSIBLE FOR THE CONTROL AND SAFETY OF THE TRAVELING PUBLIC
AND THE SAFETY OF HIS/HER PERSONNEL.
b.UTILIZE SIGNS, BARRICADES, FLAGMEN, OR GUARDS AS REQUIRED TO ENSURE THE SAFETY OF ALL VEHICULAR AND
PEDESTRIAN TRAFFIC DURING ALL CONSTRUCTION ACTIVITIES.
c.LABOR SAFETY REGULATIONS SHALL CONFORM TO THE PROVISIONS SET FORTH BY OSHA.
d.THE MINIMUM STANDARDS OF THE GOVERNING AUTHORITIES' GUIDELINES SHALL BE FOLLOWED IN THE DESIGN, APPLICATION,
INSTALLATION, MAINTENANCE, AND REMOVAL OF ALL TRAFFIC CONTROL DEVICES, WARNING DEVICES, AND BARRIERS
NECESSARY TO PROTECT THE PUBLIC AND CONSTRUCTION PERSONNEL FROM HAZARDS WITHIN THE PROJECT LIMITS.
e.ALL TRAFFIC CONTROL MARKINGS AND DEVICES SHALL CONFORM TO THE PROVISIONS SET FORTH IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES PREPARED BY THE U.S. DEPARTMENT OF TRANSPORTATION FEDERAL HIGHWAY ADMINISTRATION.
f.ALL SUBSURFACE CONSTRUCTION SHALL COMPLY WITH THE TRENCH SAFETY ACT. THE CONTRACTOR SHALL INSURE THAT THE
METHOD OF TRENCH PROTECTION AND CONSTRUCTION IS IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA) REGULATIONS. CONTRACTOR SHALL PROVIDE EXCAVATION AND TRAVELING OPERATIONS AS
REQUIRED BY LOCAL AUTHORITIES AND ALL APPLICABLE OSHA REGULATIONS.
g.UNDER ABSOLUTELY NO CIRCUMSTANCES SHALL ANY UNMANNED EXCAVATION BE LEFT OPEN OR UNPROTECTED DURING
NON-WORKING HOURS. UTILIZE SIGNS, BARRICADES, ETC. TO ENDURE THE SAFETY OF THE GENERAL PUBLIC.
h.IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY AND ENFORCE ALL APPLICABLE SAFETY
REGULATIONS. THE ABOVE INFORMATION HAS BEEN PROVIDED FOR THE CONTRACTOR'S INFORMATION ONLY AND DOES NOT
IMPLY THAT THE OWNER OR ENGINEER WILL INSPECT AND/OR ENFORCE SAFETY REGULATIONS.
CLEARING, SITE PREPARATION, GRADING & PAVING NOTES:
1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER INSTALLATION AND MAINTENANCE OF THE EROSION CONTROL
DEVICES, AS SHOWN ON THE CONSTRUCTION PLANS, PRIOR TO ANY SITE CLEARING AND/OR DEMOLITION.
2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL STATE AND LOCAL CODES IN OBSERVING EROSION CONTROL
MEASURES BOTH ON AND OFF SITE.
3.PRIOR TO ANY SITE CLEARING, ALL TREES SHOWN TO REMAIN, AS INDICATED ON THE CONSTRUCTION PLANS, SHALL BE
PROTECTED IN ACCORDANCE WITH LOCAL TREE ORDINANCES, AND DETAILS CONTAINED IN THESE PLANS. IN ADDITION, TREES AND
EXISTING LANDSCAPING NOT DESIGNATED FOR REMOVAL SHALL BE PROTECTED DURING CONSTRUCTION. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE TREES AND EXISTING LANDSCAPING IN GOOD CONDITION. NO TREE(S) SHOWN
TO REMAIN SHALL BE REMOVED WITHOUT WRITTEN APPROVAL FROM THE OWNER AND THE LOCAL AGENCY HAVING JURISDICTION
OVER THESE ACTIVITIES.
4.THE CONTRACTOR SHALL CLEAR AND GRUB ONLY THOSE PORTIONS OF THE SITE NECESSARY FOR CONSTRUCTION. ALL DISTURBED
AREAS MUST BE SEEDED AND MULCHED, SODDED OR PLANTED WITH OTHER APPROVED LANDSCAPE MATERIAL, IMMEDIATELY
FOLLOWING CONSTRUCTION AS DIRECTED BY OWNER OR LANDSCAPE ARCHITECT.
5.THE CONTRACTOR SHALL MAINTAIN AND PROTECT FROM MUD, DIRT, DEBRIS, ETC. THE STORM DRAINAGE SYSTEM UNTIL FINAL
ACCEPTANCE OF THE PROJECT. THE STORM SYSTEM WILL BE RE-INSPECTED BY THE OWNER'S ENGINEER PRIOR TO APPROVAL OF
FINAL COMPLETION. THE CONTRACTOR WILL BE REQUIRED TO RE-CLEAN PIPES AND INLETS FOR THESE PURPOSES, INCLUDING ALL
NEW AND ANY EXISTING, RE-USED PIPES AND STRUCTURE THAT ARE PART OF THE STORM SYSTEM.
6.ALL OPEN STORM DRAIN LINES SHALL BE PROTECTED WITH STONE FILTER PROTECTION AFTER STOPPAGE OF WORK EACH DAY.
7.THE TOPSOIL REMOVED DURING CLEARING AND GRUBBING ACTIVITIES MAY BE STOCKPILED TO BE USED FOR LANDSCAPING
PURPOSES, ONLY AS DIRECTED BY THE OWNER, OTHERWISE IT IS TO BE REMOVED OFF SITE. REMAINING EARTH WORK THAT
RESULTS FROM CLEARING AND GRUBBING OR SITE EXCAVATION MAY BE UTILIZED ON-SITE, PROVIDED THE MATERIAL IS DEEMED
SUITABLE BY THE SOILS TESTING COMPANY. EXCESS MATERIAL IS TO BE REMOVED FROM THE SITE. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ACQUIRING ANY PERMITS THAT ARE NECESSARY FOR REMOVING ANY EXCESS MATERIAL FROM THE SITE.
8.AT THE START OF GRADING INVOLVING THE STRIPPING OF TOPSOIL, REMOVAL OF EXISTING PAVEMENT OR LOWERING OF EXISTING
GRADE AROUND A TREE, A CLEAN SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA AT THE SAME TIME
AS OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE INSTALLED ON THE SIDE OF
THE CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF THE
TREES IS COMPLETE. NO STORAGE OF MATERIALS, FILL, OR EQUIPMENT AND NO TRESPASSING SHALL BE ALLOWED WITHIN THE
BOUNDARY OF THE PROTECTED AREA.
9.SALVAGED MATERIALS FROM SITE GRADING DETERMINED TO BE ACCEPTABLE BY AN INDEPENDENT SOIL TESTING LABORATORY
SHALL BE UTILIZED FOR FILL MATERIAL WHERE APPROPRIATE.
10.CLEAR AND GRUB ALL AREAS TO RECEIVE PAVEMENT / STRUCTURES AS REQUIRED BY SPECS.
11.ALL EXISTING DEBRIS (ABOVE OR BELOW GROUND), CONSTRUCTION DEBRIS, AND OTHER WASTE MATERIAL SHALL BE DISPOSED
OF OFF-SITE BY THE CONTRACTOR IN ACCORDANCE WITH APPLICABLE REGULATORY AGENCY REQUIREMENTS.
12.THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ALL WASTE AND EXCESS MATERIALS OFF SITE. THIS RESPONSIBILITY
SHALL INCLUDE ALL REQUIRED APPROVALS AND CONDITIONS DICTATED BY LOCAL OR STATE EROSION CONTROL AUTHORITIES.
13.THE CONTRACTOR IS TO PREPARE THE SITE IN ACCORDANCE WITH THE SOILS REPORT, COPIES OF WHICH ARE AVAILABLE
THROUGH THE OWNER OR SOILS TESTING COMPANY DIRECTLY.
14.ALL DELETERIOUS SUBSURFACE MATERIAL (I.E. MUCK, PEAT, BURIED DEBRIS, ORGANIC MATERIAL, ETC.) IS TO BE EXCAVATED AND
REPLACED WITH SUITABLE / COMPACTED SOILS AS DIRECTED BY THE OWNER, THE OWNER'S ENGINEER, OWNER'S SOILS TESTING
COMPANY AND PROJECT SPECIFICATIONS. DELETERIOUS MATERIAL IS TO BE REMOVED FROM THE SITE (UNLESS OTHERWISE
DIRECTED), EXCAVATED AREAS ARE TO BE BACKFILLED WITH APPROVED MATERIALS AND COMPACTED AS SHOWN ON THESE
PLANS, PER THE SUBSURFACE EXPLORATION AND GEOTECHNICAL RECOMMENDATIONS REPORT OR PER THE RECOMMENDATIONS
OF THE GEOTECHNICAL ENGINEER. CONTRACTOR IS RESPONSIBLE FOR ACQUIRING ANY PERMITS THAT ARE NECESSARY FOR
REMOVING DELETERIOUS MATERIAL FROM THE SITE.
15.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXCAVATIONS AGAINST COLLAPSE AND WILL PROVIDE BRACING
SHEETING OR SHORING AS NECESSARY. DEWATERING METHODS SHALL BE USED AS REQUIRED TO KEEP TRENCHES DRY WHILE
PIPE AND APPURTENANCES ARE BEING PLACED.
16.ALL NECESSARY FILL AND EMBANKMENT THAT IS PLACED DURING CONSTRUCTION SHALL CONSIST OF MATERIAL SPECIFIED BY THE
OWNER'S SOIL TESTING COMPANY OR ENGINEER AND BE PLACED AND COMPACTED ACCORDING TO THESE PLANS AND PROJECT
SPECIFICATIONS AND THE SUBSURFACE EXPLORATION REPORT.
17.CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE IF CONFLICTS EXIST WITH GRADES SHOWN, CONTACT ENGINEER PRIOR TO
CONSTRUCTION.
18.CONTRACTOR SHALL TRIM, TACK AND MATCH EXISTING PAVEMENT AT LOCATIONS WHERE NEW ASPHALT PAVEMENT MEETS
EXISTING PAVEMENT. CONTRACTOR TO PROVIDE A STRAIGHT, SAW-CUT, CLEAN JOINT WHERE NEW PAVEMENT MEETS EXISTING
PAVEMENT.
19.ASPHALT PAVEMENT SHALL BE SMOOTH, WITH STRAIGHT OVERLAPPING SEAMS, FREE OF SEGREGATION, STAINS, BIRD BATHS, AND
IMPERFECTIONS. ASPHALT PATCHING, SKIN PATCHES, OR RE-HEATING AND ROLLING WILL NOT BE ALLOWED. AREAS THAT ARE NOT
ACCEPTABLE TO THE OWNER/ENGINEER WILL BE SAWCUT AND REMOVED. NO PATCH SMALLER THAN 200 SF WILL BE ALLOWED, AND
SAW CUTS MUST FALL ON A PAINT LINE OR EXISTING SEAM.
20.PRIOR TO CONSTRUCTING CONCRETE PAVEMENT OR HARDSCAPE, THE CONTRACTOR SHALL SUBMIT PROPOSED JOINT
PLAN/PATTERN FOR ALL SCORE JOINTS, CONTROL JOINS AND EXPANSION JOINTS TO THE ENGINEER FOR APPROVAL PRIOR TO
PLACING CONCRETE.
21.CONTRACTOR TO PROVIDE A ½” TO 1” BITUMINOUS EXPANSION JOINT MATERIAL WITH SEALER AT ABUTMENT OF CONCRETE AND
OTHER RIGID MATERIAL (STRUCTURES, OTHER POURED CONCRETE, ETC.). ALL EXPANSION JOINTS TO BE SEALED WITH JOINT
SEALANT, WITH THE EXCEPTION OF THOSE PLACED IN CONCRETE SIDEWALKS.
TESTING AND INSPECTION REQUIREMENTS:
1.ALL SITE WORK CONSTRUCTION TESTING SHALL BE CONDUCTED IN ACCORDANCE WITH THE PROJECT'S GEOTECHNICAL REPORT IF
ONE WAS OBTAINED, AND / OR THE TESTING PARAMETERS OF THE LOCAL MUNICIPALITY/AGENCY HAVING JURISDICTION OVER THE
SITE WORK. THE MORE STRINGENT REQUIREMENTS SHALL APPLY.
2.ALL SITE WORK CONSTRUCTION TESTING SHALL BE PERFORMED BY A CERTIFIED / LICENSED GEOTECHNICAL ENGINEERING FIRM.
3.A QUALIFIED TESTING LABORATORY SHALL BE RETAINED BY THE OWNER AND SHALL PERFORM ALL TESTING NECESSARY TO
ASSURE COMPLIANCE OF THE IN-PLACE MATERIALS AS REQUIRED BY THESE PLANS UNLESS OTHERWISE SPECIFIED IN THE BID
DOCUMENTS. SHOULD ANY RETESTING BE REQUIRED DUE TO THE FAILURE OF ANY TESTS TO MEET THE REQUIREMENTS, THE
CONTRACTOR WILL BEAR ALL COSTS OF SAID RETESTING.
4.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING APPLICABLE TESTING WITH THE CERTIFIED ENGINEERING FIRM; TESTS
WILL BE REQUIRED PURSUANT WITH THE GEOTECHNICAL REPORT; AND PROJECT SPECIFICATIONS. UPON COMPLETION OF WORK
THE SOILS ENGINEER WILL SUBMIT CERTIFICATIONS TO THE OWNER AND THE OWNER'S ENGINEER STATING THAT ALL
REQUIREMENTS HAVE BEEN MET FOR PURPOSES SUCH AS BUT NOT LIMITED TO CERTIFICATION AND ACCEPTANCE OF FACILITIES
BY THE DEVELOPER AND/OR MUNICIPALITY/AGENCY.
5.CONTRACTOR IS TO COORDINATE WITH THE TESTING FIRM TO HAVE PERFORMED ALL CONSTRUCTION TESTING PER THE PLANS
AND SPECIFICATIONS PREPARED BY ENGINEER OF RECORD. COPIES OF ALL CONSTRUCTION TESTING SHALL BE SENT DIRECTLY TO
OWNER BY TESTING LABORATORY. IN ADDITION TO THE PLANS AND SPECIFICATIONS THE CONSTRUCTION TESTING SHALL INCLUDE:
A.DENSITY/COMPACTION TESTING OF PLACED FILL.
B.PROOF ROLL MONITORING AND EVALUATION OF SUBGRADE MATERIALS, PRIOR TO IMPORT OF FILL OR PRIOR TO PLACEMENT
OF AGGREGATE SUBBASE MATERIAL. PROVIDE RECOMMENDATIONS AND MONITOR ANY NEEDED REPAIR
C.DEPTH AND DENSITY TESTS OF CRUSHED AGGREGATE BASE COURSE SUBBASE
D.OBSERVE AND TEST UTILITY BACKFILL
E.OBSERVATION OF PROOF ROLLING SUBGRADE & CRUSHED AGGREGATE BASE COURSE SUBBASE
F.DEPTH AND DENSITY TESTS OF CRUSHED AGGREGATE BASE COURSE SUBBASE
G.DEPTH, DENSITY AND TEMPERATURE OF PLACED ASPHALT PAVEMENT
H.REPORTS OF INSPECTION & TEST RESULTS WILL BE SUBMITTED AFTER COMPLETING THE TEST OR INSPECTION
I.PROVIDE A SUMMARY LETTER UPON COMPLETION OF THE PROJECT
PROPOSED NOTE
CURB AND GUTTER
SPILL TRANSITION
DEPRESSED CURB AND GUTTER
X
TYPICAL NOTE TEXT
NEIGHBORING
PROPERTY LINE /
INTERIOR PARCEL LINE
STANDARD DRAWING LEGEND
FOR ENTIRE PLAN SET
ONSITE PROPERTY
LINE / R.O.W. LINE
EASEMENT
LINE
SETBACK
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
BORING
BENCHMARK
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
SAN
#
X
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
GRATE
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
TC
BC
516.00
515.55
TC 516.00
190CONTOUR
LINE
SPOT
ELEVATIONS
187
STORM DRAIN
SANITARY SEWER
WATER
SIGHT DISTANCE
PROPOSED EASEMENT LEGEND
COMMON SHARED
INGRESS-EGRESS
PUBLIC ACCESS
PUBLIC UTILITY PU
IE
CSE
PADIM
W
SS
STM
DIM
DIM
DIM
DIM
DIM
DIM
-VAR VARIABLE WIDTH S
SI
DIM
STANDARD
ABBREVIATIONS
FOR ENTIRE PLAN SET
AC ACRES
ADA AMERICANS WITH
DISABILITY ACT
ARCH ARCHITECTURAL
BC BOTTOM OF CURB
BF BASEMENT FLOOR
BK BLOCK
BL BASELINE
BLDG BUILDING
BM BUILDING BENCHMARK
BRL BUILDING RESTRICTION LINE
CF CUBIC FEET
CL CENTERLINE
CMP CORRUGATED METAL PIPE
CONN CONNECTION
CONC CONCRETE
CPP CORRUGATED PLASTIC PIPE
CY CUBIC YARDS
DEC DECORATIVE
DEP DEPRESSED
DIP DUCTILE IRON PIPE
DOM DOMESTIC
ELEC ELECTRIC
ELEV ELEVATION
EP EDGE OF PAVEMENT
ES EDGE OF SHOULDER
EW END WALL
EX EXISTING
FES FLARED END SECTION
FF FINISHED FLOOR
FH FIRE HYDRANT
FG FINISHED GRADE
G GRADE
GF GARAGE FLOOR (AT DOOR)
GH GRADE HIGHER SIDE OF WALL
GL GRADE LOWER SIDE OF WALL
GRT GRATE
GV GATE VALVE
HDPE HIGH DENSITY
POLYETHYLENE PIPE
HP HIGH POINT
HOR HORIZONTAL
HW HEADWALL
INT INTERSECTION
INV INVERT
LF LINEAR FOOT
LOC LIMITS OF CLEARING
LOD LIMITS OF DISTURBANCE
LOS LINE OF SIGHT
LP LOW POINT
L/S LANDSCAPE
MAX MAXIMUM
MIN MINIMUM
MH MANHOLE
MJ MECHANICAL JOINT
OC ON CENTER
PA POINT OF ANALYSIS
PC POINT CURVATURE
PCCR POINT OF COMPOUND
CURVATURE, CURB RETURN
PI POINT OF INTERSECTION
POG POINT OF GRADE
PROP PROPOSED
PT POINT OF TANGENCY
PTCR POINT OF TANGENCY,
CURB RETURN
PVC POLYVINYL CHLORIDE PIPE
PVI POINT OF VERTICAL
INTERSECTION
PVT POINT OF VERTICAL TANGENCY
R RADIUS
RCP REINFORCED CONCRETE PIPE
RET WALL RETAINING WALL
R/W RIGHT OF WAY
S SLOPE
SAN SANITARY SEWER
SF SQUARE FEET
STA STATION
STM STORM
S/W SIDEWALK
TBR TO BE REMOVED
TBRL TO BE RELOCATED
TC TOP OF CURB
TELE TELEPHONE
TPF TREE PROTECTION FENCE
TW TOP OF WALL
TYP TYPICAL
UG UNDERGROUND
UP UTILITY POLE
W WIDE
W/L WATER LINE
W/M WATER METER
±PLUS OR MINUS
°DEGREE
Ø DIAMETER
#NUMBER
LOW LOW
LOD LOD
LIMIT OF WORK
LIMIT OF DISTURBANCE
MATCH EX
(518.02 ±)
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-104 LEGENDS AND ABBREVIATIONSJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-104
LEGENDS AND
ABBREVIATIONS
LODLODL
O
D
LOD LOD LODLOD
LOD
LODLODLOD LOD LODLODLODLODLODLODLOD LOD LODLOD LODLODLODLOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD LODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD LODLODLODLODLODLODLODLO
D
LOD LOD
LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLO
D
LOD
LODLODLODLODLODLODLODLODLOD50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X5
0
'BUILD
I
N
GENVE
L
O
P
E
2,500
S
F
50'X50'
BUILDING
ENVELOPE
2,500 SF 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'
BUILDI
N
G
ENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'
BUILDINGENVELOPE2,500 SF50'X50'
BUILDI
N
G
ENVELO
P
E
2,500 S
F
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUIL
D
I
N
GENVEL
O
P
E3,600
S
F
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDIN
GENVELOPE3,600 SF
60'X60'BUILDIN
GENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
50'X50'BUILDINGENVELOP
E
2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X
6
0
'BUIL
D
I
N
G
ENVE
L
O
P
E
3,600
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60
'
X
6
0
'
BU
I
L
D
IN
G
EN
V
E
LO
P
E
3,
6
0
0
S
F60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDIN
G
ENVELOP
E
3,600 SF
60
'
X
6
0
'
B
U
I
L
D
I
NG
EN
V
E
LO
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE3,600 SF
60'X60'BUILDI
N
GENVEL
O
P
E
3,600
S
F 60'X60'
BUIL
DING
ENVELOPE
3,600 SF60'X60'BUILDINGENVELOP
E
3,600
SF 60'X60'
BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60
'
BUILDIN
G
ENVEL
O
P
E
3,600 S
F
50'X50'
BUILDING
ENVELOPE2,500 SF
60'X6
0'
BUILDI
N
G
ENVELOPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'
X
6
0
'
BUI
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X6
0'
BUILDI
N
G
ENVEL
OPE
3,600 S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 SF
60'X60'BUIL
DING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVELO
P
E
3,600 S
F
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDINGENVELOPE
3,600 SF
60'X60'BUILDING
ENVELOP
E
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDINGENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDINGENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDIN
G
ENVEL
O
P
E
3,600 S
F 60'X60'BUILDINGENVELOP
E
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDINGENVELOPE
2,500 SF
50'X50'BUILDING
ENVELOPE
2,500 SF
60'X60'BUILDI
N
GENVELOP
E3,600 SF
60'X60'BUILDINGENVELOPE3,600 SFFFFF
F F
F F FFFFFA B
G
CDEFHIKJNMLSDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-110 KEY MAPJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-110
KEY MAP
W E
SNAD83 NAD831"=250'
0 25062.5125250
LODLOD
LODLOD LOD LOD LODLODLODLODLOD
LODLODLOD LOD LODLODLOD LODLOD
LODLODLOD LOD LOD LODLOD LODL
O
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD
LOD
LOD
LOD
LOD LODLODLODLOD
LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD
LOD
LOD LODLODLODLODLODLODLODLODLO
D
LOD
LOD LOD
LOD LOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLO
D
LODLODLODLODLODLOD50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X
5
0
'BUIL
D
I
N
GENVE
L
O
P
E
2,500
S
F
50'X50'
BUILDING
ENVELOPE
2,500 SF 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'
BUILDI
N
G
ENVELO
P
E
2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X5
0'BUILDING
ENVELOPE2,500 SF50'X50'
BUILDI
N
G
ENVEL
O
P
E
2,500 S
F
50'X50'
BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60
'BUILD
I
N
GENVEL
O
P
E
3,600
S
F
60
'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDIN
G
ENVELO
P
E
3,600 SF
60'X60'BUILDIN
GENVELO
P
E
3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
50'X50'
BUILDIN
G
ENVELOP
E
2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X
6
0
'BUIL
D
I
N
G
ENV
E
L
O
P
E
3,60
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60
'
X
6
0
'
B
U
I
L
D
ING
EN
V
E
L
O
P
E
3,
6
0
0
S
F60'X60'BUILDI
NG
ENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDIN
G
ENVEL
O
P
E
3,600 S
F
60
'
X
6
0
'
B
U
I
L
D
IN
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X6
0
'
BUILDI
N
GENVEL
O
P
E
3,600
S
F 60'X60'BUILDING
ENVEL
OPE
3,600 SF60'X60'BUILDING
ENVEL
OPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
S
F
50'X50'
BUILDING
ENVELOPE2,500 SF
60'X60'
BUILDI
N
G
ENVELO
PE
3,600
S
F 60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60
'
X
6
0
'
B
U
I
L
D
I
N
G
EN
V
E
LO
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELO
PE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDIN
G
ENVELOP
E
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDIN
G
ENVELOP
E
3,600 S
F
60'X60
'
BUILDI
N
G
ENVEL
O
P
E
3,600 S
F
60'X60'BUILDI
NG
ENVEL
OPE
3,600 SF60'X60'BUILDING
ENVELOPE3,600 SF 60'X60'
BUILDI
N
G
ENVE
L
O
P
E
3,600
S
F
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVELO
P
E
3,600
S
F 60'X60'BUILDING
ENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X50'
BUILDING
ENVELOPE
2,500 SF
60'X60'
BUILDIN
GENVELO
P
E
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SFFFFF
F
F
F F F F
F FFFFFFSDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-111 PHASING PLANJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-111
PHASING PLAN
W E
SNAD83 NAD831"=200'
0 20050100200
PHASE 3
SECTION 3
PHASE 3
SECTION 2
PHASE 3
SECTION 1
A
B D
E
C
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-112 MASTER LOT MAPJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-112
MASTER LOT
MAP
W E
SNAD83 NAD831"=250'
0 25062.5125250
232
36944 SF.
0.85 AC.
231
28214 SF.
0.65 AC.
230
23314 SF.
0.54 AC.
229
24642 SF.
0.57 AC.
228
25173 SF.
0.58 AC.
227
25396 SF.
0.58 AC.
226
28250 SF.
0.65 AC.
225
37504 SF.
0.86 AC.
224
37503 SF.
0.86 AC.
223
37502 SF.
0.86 AC.
222
37502 SF.
0.86 AC.
221
37501 SF.
0.86 AC.
220
37501 SF.
0.86 AC.
219
37458 SF.
0.86 AC.
218
36243 SF.
0.83 AC.
210
243
116671 SF.
2.68 AC.
242
119314 SF.
2.74 AC.
241
83100 SF.
1.91 AC.
240
54338 SF.
1.25 AC.
239
38795 SF.
0.89 AC.
238
35734 SF.
0.82 AC.
237
24950 SF.
0.57 AC.
254
52131 SF.
1.20 AC.
248
36429 SF.
0.84 AC.
247
110431 SF.
2.54 AC.
250
22742 SF.
0.52 AC.
249
20309 SF.
0.47 AC.
246
106695 SF.
2.45 AC.
245
25049 SF.
0.58 AC.
244
25480 SF.
0.58 AC.
260
70133 SF.
1.61 AC.
259
20000 SF.
0.46 AC.
258
20866 SF.
0.48 AC.
257
20866 SF.
0.48 AC.
256
20000 SF.
0.46 AC.
255
70120 SF.
1.61 AC.
253
17975 SF.
0.41 AC.
252
20000 SF.
0.46 AC.
251
20866 SF.
0.48 AC.
N89°55'25"W
200.00'N0°04'35"E330.12'S89°56'20"E
225.00'
N89°55'25"W
200.00'N0°04'35"E100.00'N89°55'25"W
175.00'N0°04'35"E105.00'N89°55'25"W
175.00'R=2
5.00'L=3
9.27'N0°04'35"E80.00'S89°55'25"E
200.00'N0°04'35"E100.00'S89°55'25"E
200.00'R=25.00'L=21.03'R=50.00'
L
=
1
2
0.59'N0°04'35"E224.15'S89°56'20"E
225.00'R=5 0.0 0 'L=5 2 .3 6 '
N59
°
5
5
'
2
5
"
W
38.
2
0
'N89°55'25"W
148.62'N0°04'35"E229.99'S89°56'20"E
225.00'R=50.00'L=68.23'
R
=
2
5
.00'L=
2
1.03'N89°55'25"W
200.00'N0°04'35"E16.31'N0°04'35"E83.69'S0°04'35"W100.00'N89°55'25"W
200.00'N0°04'35"E16.00'N0°04'35"E84.00'S0°04'35"W80.00'R =2 5.00'L =39.27'N89°55'25"W
175.00'N0°04'35"E105.00'N89°55'25"W
175.00'R=2
5.00'L=3
7.30'N4°26'47"W81.90'N85°33'13"E
207.02'N4°26'47"W44.10'R=25.00'L=21.03'R=50.00'L=42.05'N85°33'13"E
189.93'R=
5
0
.00'L=
4
3
.42'N35°47'52"E359.68'R =50.00'L =55.11'N27
°20
'
57
"W323.8
2
'
S89°56'03"E
59.30'N0°19'34"E250.62'S89°48'40"E
172.96'S0°02'26"E249.53'S89°56'20"E
177.50'R=50.00'L=58.55'S85°33'13"W
254.22'N27
°
04
'4
6
"W
3
99
.81
'
S89°56'03"E
313.57'S27°04
'
46
"E
108
.3
4
'S2
7
°04
'
46
"E
157
.20
'
R =52 5 .0 0 'L =9 4 .0 1 'N
3
7
°
2
0
'
1
9
"W
8
0
8
.
4
3
'
S89°56'03"E
266.89'
R =525.00'L=93.88'N4
7
°
3
5
'
0
1
"
W
63
3
.
4
3
'N0°09'46"W278.85'S89°56'03"E
47.26'R=525.00'L=99.21'N5
8
°
2
4
'
3
8
"
W
478
.
1
4
'N0°09'46"W255.90'R=525.00'L=113.52'N61
°
0
2
'
2
2
"
W
409.
4
7
'N0°09'46"W154.55'R=475.00'L=113.07'N5
7
°
0
9
'
3
8
"
W
367
.
1
7
'N0°09'46"W100.53'R=475.00'L=51.16'S39°00'38"W73.91'N5
0
°
5
9
'
2
2
"
W
29
8
.
1
3
'N0°09'46"W110.29'N5
0
°
5
9
'
2
2
"
W
19
1
.
6
5
'N0°09'46"W128.99'N0°09'46"W64.46'N39°00'38"E73.91'R=525.00'L=26.10'R=525.00'L=100.15'S64°
4
6
'
0
5
"
E
279.
0
0
'S21°24'15"W103.19'R=525.00'L=55.27'R=475.00'L=44.78'S65°
2
4
'
3
9
"
E
277.
6
4
'
S5
1
°
5
1
'
0
7
"
E
33
0
.
1
3
'
S83°40'04"W
65.89'R=475.00'L=112.30'S
3
8
°
1
8
'
2
0
"
E
3
5
5
.
3
4
'
S83°40'04"W
40.00'R=475.00'L=112.30'S24°45'33
"E368
.01
'
S83°40'04"W
29.54'
R =4 7 5 .0 0 'L =1 1 2 .3 0 'S83°40'04"W
25.15'
R =4 7 5 .0 0 'L =11 2 .3 0 'S11°12'46"E373.09
'S11°12'46"E0.04
'S0°04'35"W375.05'N89°56'20"W
38.66'
R =4 75.00 '
L =9 3.59 '
S89°55'25"E
18.71'S0°04'35"W375.03'N89°55'36"W
34.73'
N89°56'20"W
65.27'
S89°55'25"E
100.00'S0°04'35"W375.02'N89°55'36"W
100.00'
S89°55'25"E
100.00'S0°04'35"W375.02'N89°55'36"W
56.56'
N89°55'36"W
43.44'
S89°55'25"E
100.00'S0°04'35"W375.01'N89°55'36"W
100.00'
S89°55'25"E
100.00'S0°04'35"W375.01'N89°55'36"W
96.98'
N89°55'36"W
3.02'
S89°55'25"E
100.00'S0°04'35"W375.00'N89°55'36"W
95.78'
N89°55'36"W
4.22'
S89°55'25"E
100.00'S0°04'35"W371.15'S80°10'57"W
22.43'
N89°55'36"W
72.49'
N89°55'36"W
5.41'
S89°55'25"E
100.00'
S80°10'57"W
95.56'
S80°10'57"W
5.94'
S89°55'25"E
100.00'N8°45'23"W270.08'N8°45'23"W280.69'S4°26'47"E81.94'
R =25.00'L =36.99'R =5 2 5 .0 0 'L =1 5 9 .5 9 '
N85°33'13"E
237.53'S4°26'47"E44.10'R=50
.0
0
'L=42.
0
5'R
=
2
5.00'L=
2
1
.03'SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-113 MASTER LOT MAP - AJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-113
MASTER LOT
MAP - A
W E
SNAD83 NAD831"=250'
0 25062.5125250
205
113801 SF.
2.61 AC.
233
32167 SF.
0.74 AC.
232
36944 SF.
0.85 AC.
231
28214 SF.
0.65 AC.
210
27362 SF.
0.63 AC.
209
28845 SF.
0.66 AC.
208
30399 SF.
0.70 AC.
207
41852 SF.
0.96 AC.
206
50316 SF.
1.16 AC.
238
35734 SF.
0.82 AC.
237
24950 SF.
0.57 AC.
236
29358 SF.
0.67 AC.
235
61535 SF.
1.41 AC.
234
49335 SF.
1.13 AC.
288
23194 SF.
0.53 AC.
287
25847 SF.
0.59 AC.
286
25044 SF.
0.57 AC.
285
26371 SF.
0.61 AC.
284
24625 SF.
0.57 AC.
283
25205 SF.
0.58 AC.
282
28125 SF.
0.65 AC.
281
27826 SF.
0.64 AC.
280
30184 SF.
0.69 AC.
S61
°
1
7
'
0
1
"
E
245.
4
8
'S38°31'47"W74.33'N74°20'
5
6
"
W
224.38'R=550.00'L=125.05'S5
1
°
2
7
'
1
8
"
E
25
0
.
4
5
'S38°31'47"W82.74'R=550.00'L=94.72'N37°40'46"E30.40'S5
1
°
2
7
'
1
8
"
E
25
0
.
4
2
'S38°31'47"W100.00'N38°32'42"E100.00'S38°22'47"W86.41'N38°32'42"E39.12'R=550.00'L=86.05'S
4
2
°
2
9
'
2
5
"
E
2
4
6
.
4
7
'S2
9
°
26
'2
5
"E
2
6
3
.
3
0
'
S68°02'1
9
"
W
69.13'
R =5 50 .00 'L =1 2 5.2 7 'S16°23'26"E264.39'
S68°02'1
9
"
W
65.04'
R =5 5 0 .0 0 'L =1 2 5 .2 7 'S8°45'23"E266.46'
N85°29'04"W
45.00'
S68°02'
1
9
"
W
47.24'
R =5 5 0 .0 0'
L =7 3 .2 8 'N81°14'37"E
51.84'S8°45'23"E290.05'N85°29'04"W
102.74'
N81°14'37"E
100.00'S8°45'23"E313.64'
N85°29'04"W
102.74'
N81°14'37"E
100.00'
N81°14'37"E
100.00'R=475.L=113.0R=475.00'L=51.16'S39°00'38"W73.91'N5
0
°
5
9
'
2
2
"
W
29
8
.
1
3
'S39°00'38"W
44.10'R=2 5 .00'L=2 1 .0 3'R =5 0 .0 0 'L=4 2 .0 5 '
N5
0
°
5
9
'
2
2
"
W
19
1
.
6
5
'N0°09'46"W128.99'R=50.00'L=67.78'S51°1
2'
01"
W219.40'N5°00'13"E257.35'N0°09'46"W64.46'S12°00'08"E231.02'
S56°5
0'
2
8"
W
247.0
0'N14°20'08"W80.95
'N14°20'51"W168.07
'
R=50.00'L=55.27'
S56°5
0'
2
8"
W
290.7
7'
R =50.00'L=76.08'R=25.00'L=21.03'N39°00'38"E44.10'S5
0
°
5
9
'
2
2
"
E
28
2
.
4
6
'
S5
3
°
5
0
'
1
7
"
E
30
4
.
5
8
'S21°24'15"W26.18'S56°5
0'
2
8"
W
94.73'N39°00'38"E73.91'R=525.00'L=26.10'S21°24'15"W157.65'R=525.00'L=100.15'S64°
4
6
'
0
5
"
E
279.0
0
'S21°24'15"W103.19'R=5L=5S83°40'04"W
65.89'
S83°40'04"W
40.00'
S83°40'04"W
29.54'
S83°40'04"W
25.15'S11°12'46"E0.04'N89°56'20"W
38.66'
N89°55'36"W
34.73'
N89°56'20"W
65.27'
N89°55'36"W
100.00'
N89°55'36"W
56.56'
N89°55'36"W
43.44'
N89°55'36"W
100.00'
N89°55'36"W
96.98'
N89°55'36"W
3.02'
N89°55'36"W
95.78'
N89°55'36"W
4.22'
S80°10'57"W
22.43'
N89°55'36"W
72.49'
N89°55'36"W
5.41'S80°10'57"W
95.56'
S80°10'57"W
5.94'N8°45'23"W270.08'
S81°14'37"W
100.00'N8°45'23"W280.69
'
S81°14'37"W
100.00'N8°45'23"W296.22'
R =6 0 0 .0 0 'L =1 0 0 .12 'N18°19'00"W349.44
'S8°45'23"E311.75'
R =6 0 0 .0 0 'L =1 0 0 .1 2 'N27°5
0
'
07
"W419
.7
6
'
R =600.00'L =246 .9 1'S38°32'42"W
169.54'R=600.00'L=330.57'N83°01'18"W
200.20'N37°26'20"E293.62'N38°31'47"E393.49'N0°05'16"W396.25'S81°14'37"W
100.00'
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-114 MASTER LOT MAP - BJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-114
MASTER LOT
MAP - B
W E
SNAD83 NAD831"=250'
0 25062.5125250
273
50361 SF.
1.16 AC.
345
30361 SF.
0.70 AC.
344
26491 SF.
0.61 AC.
219
37458 SF.
0.86 AC.
218
36243 SF.
0.83 AC.
217
34498 SF.
0.79 AC.
216
32690 SF.
0.75 AC.
215
30016 SF.
0.69 AC.
214
38634 SF.
0.89 AC.
213
78973 SF.
1.81 AC.
212
27286 SF.
0.63 AC.211
27101 SF.
0.62 AC.210
27362 SF.
0.63 AC.
261
70147 SF.
1.61 AC.
260
70133 SF.
1.61 AC.
259
20000 SF.
0.46 AC.
258
20866 SF.
0.48 AC.
267
80404 SF.
1.85 AC.
268
46845 SF.
1.08 AC.
266
36462 SF.
0.84 AC.
262
20000 SF.
0.46 AC.
263
20866 SF.
0.48 AC.
265
20337 SF.
0.47 AC.
264
22787 SF.
0.52 AC.
269
20013 SF.
0.46 AC.
272
41036 SF.
0.94 AC.
271
35434 SF.
0.81 AC.
347
54306 SF.
1.25 AC.
348
22900 SF.
0.53 AC.
270
20022 SF.
0.46 AC.
346
37386 SF.
0.86 AC.
S88°28'21"E S1°31'39"W100.00'N4°16'50"W13.77'N4°16'50"W86.75'S88°28'21"E
270.00'R=50.00'L=24.43'S1°31'39"W38.09'N21°15'51"E185.77'S60
°
2
8
'
3
4
"
E
241.
3
6
'
R =5 0 .0 0'
L =8 3 .6 6 '
N73°23'50
"
E
331.22'S0°13'44"E142.62'S32°54'19"W65.33'S1°30'44"W323.88'N88°28'21"W
194.59'R=50.00'L=75.16'N73°23'50
"
E
189.72'S1°30'44"W100.00'237.92'N1°31'39"E47.54'R=35.00'L=40.12'R =5 0.00'L =3 1.14'=3 2 5 .0 0 'R =32 5.0 0'L =104 .1 2'R=325.00'L=104.12'S63
°
4
9
'
2
7
"
E
335.
4
7
'R=325.00'L=104.12'S82°17'32"E
201.10'
N73°23'50
"
E
138.14'S4°41'22"W267.91'R=325.00'L=17.67'N4°42'18"E124.09'N64°42'
1
8
"
E
231.25'S4°41'22"W119.07'N4°42'18"E209.47'N4°42'18"E25.35'S85°15'31"E
200.24'S4°41'22"W100.00'N4°42'18"E100.00'S85°17'42"E
0.20'S85°15'31"E
200.01'S4°41'22"W100.00'N85°15'31"W
0.20'N4°42'18"E90.18'R=25.00'L=10.09'S85°15'31"E
198.17'S4°41'22"W398.32'R=25.00 'L=10.94 'R=50.00'L=92.16'N37°17'33"E367.90'R =5 0.00'
L =6 3.68'
N
3
5
°
3
9
'
1
4
"W
3
6
0
.
1
3
'
S89°56'20"E
492.30'S4°41'22"W0.26'R=50.00'L=43.30'N85°17'42"W
190.30'N0°04'35"E313.53'R=50.00
'L=42.05'
R
=
2
5.00'L
=
2
1.03'S4°42'18"W44.10'N85°17'42"W
207.21'N0°04'35"E83.62'N0°04'35"E16.71'S4°42'18"W81.94'R=2 5.00'L =3 7.25'N89°55'25"W
175.00'N0°04'35"E105.00'N0°04'35"E16.38'S4°42'18"W218.72'S73°39'29
"
W
142.94'N0°04'35"E285.42'S89°55'25"E
129.84'
R=2
5.
0
0'
L=4
1.
2
9'S73°39'29
"
W
104.25'N0°04'35"E314.89'S89°55'25"E
100.00'
S73°39'29
"
W
34.07'
S80°10'57"W
65.37'
S80°10'57"W
2.96'N0°04'35"E336.26'S89°55'25"E
100.00'
S80°10'57"W
97.06'
S80°10'57"W
4.45'N0°04'35"E353.70'S89°55'25"E
100.00'
N89°55'25"W
175.00'R=2
5.00'L=3
9.27'N0°04'35"E80.00'S89°55'25"E
200.00'N0°04'35"E100.00'S89°55'25"E
200.00'R=25.00'L=21.03'R
=50.00'
L
=
1
20.59'N0°04'35"E224.27'S89°56'20"E
225.00'R=50.00'L=120.59'R
=
2
5.00'L=
2
1.03'N89°55'25"W
200.00'
S89°56'20"E
225.00'S0°04'35"W100.00'N89°55'25"W
200.00'S0°04'35"W80.00'R =25.00'L =39.27'N89°55'25"W
175.00'S0°04'35"W371.15'S80°10'57"W
22.43'
N89°55'36"W
72.49'
S89°55'25"E
100.00'
S80°10'57"W
95.56'
S80°10'57"W
5.94'
S89°55'25"E
100.00'R=275.00'L=367.36'S81°14'37"W
52.51'N8°45'23"W273.79'S4°42'18"W104.00'S81°14'37"W
100.00'N8°45'23"W271.94'S81°14'37"W
100.00'N8°45'23"W270.08'
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-115 MASTER LOT MAP - CJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-115
MASTER LOT
MAP - C
W E
SNAD83 NAD831"=250'
0 25062.5125250
274
69767 SF.
1.60 AC.
273
50361 SF.
1.16 AC.
345
30361 SF.
0.70 AC.
344
26491 SF.
0.61 AC.
343
47531 SF.
1.09 AC.
212
27286 SF.
0.63 AC.211
27101 SF.
0.62 AC.210
27362 SF.
0.63 AC.
280
30184 SF.
0.69 AC.
279
32543 SF.
0.75 AC.
278
34902 SF.
0.80 AC.
277
37517 SF.
0.86 AC.
276
69224 SF.
1.59 AC.
275
71994 SF.
1.65 AC.
339
36251 SF.
0.83 AC.
352
23801 SF.
0.55 AC.
348
22900 SF.
0.53 AC.
349
23793 SF.
0.55 AC.
350
23796 SF.
0.55 AC.
351
23799 SF.
0.55 AC.
336
40062 SF.
0.92 AC.
337
39007 SF.
0.90 AC.
338
37703 SF.
0.87 AC.
355
24432 SF.
0.56 AC.
354
23903 SF.
0.55 AC.
353
23804 SF.
0.55 AC.
358
25867 SF.
0.59 AC.
357
25169 SF.
0.58 AC.
356
24691 SF.
0.57 AC.
334
41554 SF.
0.95 AC.
335
40910 SF.
0.94 AC.
359
26789 SF.
0.61 AC.
360
27937 SF.
0.64 AC.=4975.00'L=100.69'N11°15'44"E101.46'S88°28'21"E
412.66'R=4975.00'L=100.47'N11°15'44"E101.46'S88°28'21"E
405.20'R=4975.00'L=100.29'N11°15'44"E101.46'S88°28'21"E
395.71'R=4975.00'L=100.16'N11°15'44"E82.75'N12°59'59"E18.82'S88°28'21"E
383.61'R=4975.00'L=100.07'N11°14'49"E101.46'S88°28'21"E
370.11'R=4975.00'L=100.01'N11°14'49"E101.46'S88°28'21"E
354.59'
342
46387 SF.
1.06 AC.
340
34671 SF.
0.80 AC.
341
42541 SF.
0.98 AC.S1°31'39"W69.95'R=4975.00'L=30.05'N11°14'49"E101.82'S88°24'43"E
337.49'S1°31'39"W135.00'N19°36'38"E141.64'S88°28'21"E
293.52'N19°36'38"E173.98'N4°16'50"W9.67'S88°28'21"E
240.50'S1°31'39"W175.00'S1°31'39"W190.00'N4°16'50"W190.98'S88°28'21"E
259.83'S1°31'39"W100.00'N4°16'50"W13.77'N4°16'50"W86.75'S88°28'21"E
270.00'R=50.00'L=24.43'S1°31'39"W38.09'N21°15'51"E185.77'R =5 0 .00'
L =8 3.66'S32°54'19"WN88°28'21"W
194.59'R=50.00'L=75.16'S1°30'44"W100.00'N88°28'21"W
237.92'N1°31'39"E47.54'R=35.00'L=40.12'R =50.00'L =31.14'S1°30'44"W100.00'N88°28'21"W
237.95'N1°31'39"E100.00'S1°30'44"W100.00'N88°28'21"W
237.97'N1°31'39"E100.00'S1°30'44"W100.00'N88°28'21"W
238.00'N1°31'39"E100.00'S1°30'44"W100.00'N88°28'21"W
238.03'N1°31'39"E100.00'S1°30'44"W100.00'N88°28'21"W
238.05'N1°31'39"E100.00'S1°30'44"W100.80'N88°16'44"W
238.11'R=5025.00'L=16.96'N1°31'39"E83.04'S1°30'44"W104.76'N87°08'20"W
239.54'R=5025.00'L=100.00'S1°30'44"W104.86'N85°59'55"W
243.05'R=5025.00'L=100.00'S1°30'44"W105.04'N84°51'30"W
248.65'R=5025.00'L=100.00'S1°30'44"W105.31'N83°43'05"W
256.37'R=5025.00'L=100.00'S1°30'44"W105.66'N82°34'40"W
266.20'R=5025.00'L=100.00'S1°30'44"WR=5025.00'L=100.00'S8°45'23"E313.64'N85°29'04"W
102.74'
N81°14'37"E
100.00'S8°45'23"E337.23'
N85°29'04"W
102.74'
N81°14'37"E
100.00'S8°45'23"E360.81
'
N85°29'04"W
102.74'
N81°14'37"E
100.00'S8°45'23"E384.56'N85°29'04"W
103.43'
N81°14'37"E
100.67'S27
°06
'
44
"E410
.
2
7
'
S61°2
2'
5
8"
W
118.09'
N85°29'04"W
123.79'
R =3 2 5 .0 0 '
L =10 4 .1 2 'S61°2
2'
5
8
"
W
241.94'
R =3 25 .00 'L=1 04.12'S
4
5
°
2
8
'
0
5
"
E
44
2
.
9
9
'
S61°2
2'
5
8"
W
69.80'R=325.00'L=104.12'S63
°
4
9
'
2
7
"
E
335.
4
7
'R=275.00'L=367.36'S81°14'37"W
52.51'N8°45'23"W273.79'S81°14'37"W
100.00'N8°45'23"W271.94
'
S81°14'37"W
100.00'N8°45'23"W270.08'
S81°14'37"W
100.00'
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-116 MASTER LOT MAP - DJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-116
MASTER LOT
MAP - D
W E
SNAD83 NAD831"=250'
0 25062.5125250
334
41554 SF.
0.95 AC.360
27937 SF.
0.64 AC.
361
29315 SF.
0.67 AC.
362
30927 SF.
0.71 AC.
363
32779 SF.
0.75 AC.
331
43592 SF.
1.00 AC.
332
42552 SF.
0.98 AC.
333
41993 SF.
0.96 AC.
366
65290 SF.
1.50 AC.
365
47369 SF.
1.09 AC.
364
86528 SF.
1.99 AC.
330
26865 SF.
0.62 AC.
329
69936 SF.
1.61 AC.
368
64008 SF.
1.47 AC.
369
58670 SF.
1.35 AC.
367
64576 SF.
1.48 AC.
370
20124 SF.
0.46 AC.
371
20023 SF.
0.46 AC.
372
25704 SF.
0.59 AC.S8°09'12"E209.82'S69°59'1
8
"
W
266.83'
S70°31'5
6
"
W
92.16'N0°16'29"W128.92'N50°17'19"
E
341.77'R=50.00'L=51.00'
S69°59'1
8
"
W
449.85'R=50.00'L=112.78'S71°47
'
1
8
"
E
448.13'R=50.00'L=51.00'N0°16'29"W322.39'N0°16'29"W55.16'S71°3
3
'
0
5
"
E
277.93'R=4975.00'L=24.51'S1°30'44"W157.73'S69°59'1
8
"
W
1.28'R=35.00'L=39.86'R=5025.00'L=108.35'S73°23
'
0
5
"
E
426.37'S1°30'44"W125.33'R=5025.00'L=85.28'R=25 .0 0 'L=39 .0 0 '
S74°58'
5
2
"
E
370.29'R=4975.00'L=140.32'N72°4
2
'
3
1
"
W
129.50'N17°17'29"E140.50'R=470.00'
L=102.40'R=
2
5
.00'L=4
1
.74'N0°16'29"W134.51'N74°52'20"
E
114.84'
R =4 7 0 .0 0'
L=10 3 .81'
S74°52'20"
W
176.97'
R =53 0.0 0'
L =14 8.9 7'
S74°52'20"
W
220.70'N16°55'43"E54.50'N16°55'43"E231.22'S88°28'21"E
280.54'S0°58'34"W190.00'R=4975.00'L=101.60'N88°28'21"W
160.00'N16°55'43"E103.72'S88°28'21"E
430.96'R=4975.00'L=101.25'N16°55'43"E82.34'N11°15'44"E20.92'S88°28'21"E
421.44'R=4975.00'L=100.95'N11°15'44"E101.46'S88°28'21"E
418.08'R=4975.00'L=100.69'N11°15'44"E101.46'S88°28'21"E
412.66'
N82°34'40"W
266.20'S1°30'44"W106.09'N81°26'15"W
278.17'R=5025.00'L=100.00'S1°30'44"W106.62'N80°17'51"W
292.31'R=5025.00'L=100.00'S1°30'44"W107.23'N79°09'26"W
308.64'R=5025.00'L=100.00'S1°30'44"W107.93'N78°01'01"
W
327.20'R=5025.00'L=100.00'S1°30'44"W260.67'N74°58'5
2
"
W
355.87'R=25.00'L=39
.0
0'R=5025.00'L=211.52'R=4975.00'L=181.99'R=2 5 .00'L =3 7 .79'R=530.00'L=92.80'
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-117 MASTER LOT MAP - EJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-117
MASTER LOT
MAP - E
W E
SNAD83 NAD831"=250'
0 25062.5125250
LOD
LOD
LODLOD LOD LOD LODLODLODLODLOD
LODLODLOD LOD LODLODLOD LODLOD
LODLODLOD LOD LOD LODLOD LODL
O
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD
LOD
LOD
LOD LOD LODLODLODLOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD
LOD
LOD LODLODLODLODLODLODLODLODLO
D
LOD
LOD LOD
LOD LOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLO
D
LODLODLODLODLODLODSFSFSFSF
SF SF
SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSF
SF
SFSFSFSFSFSFSF
SF
SFSFSFSFSFSFSFSF
SF
SF
SF SF SFSFSFSF SF
SF SFSFSFSFSFSFSFSFSFSFSF
SF SFS
F
SFSF SF SF SFS
F
SFSFSF SF SFSFSFSFSFSF SF SF SFSFSFSFSFSFSFSFA B
G
CDEFHIKNMLW E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-200 OVERALL DEMO & PH 1 EROSION PLANJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-200
OVERALL DEMO
& PH 1
EROSION PLAN
OAP-0
1"=200'
0 20050100200
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD
LOD
LOD LODLODLOD
LOD
LOD
LOD LODLOD
LODKINGWOOD COURTEXECU
T
I
V
E
D
R
I
V
E
WETLANDS
AREA
848,034 SF
OR
19.47 AC.SF
SF
SF
SF
SF
SF
SF
SF
SF SF SF SF SF SF
SF
SF
SF
SF
SF
DRAINAGE AREA #1
±0.81 AC DIST. AREA TO ±482 LF SF
PROP. CLEAN WATER DIVERSION #1
ACF DOUBLE STRAW LINED
PROP. CONC. WASHOUT
PROP. CONSTR. ENTRANCE
52.
5
'37'A W E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-201 DEMO & PHASE I EROSION CONTROL PLAN - AJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-201
DEMO & PHASE
I EROSION
CONTROL PLAN
- A
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-202DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LODLOD
LOD
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD LOD
LOD
LOD
LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTACKETT COURTEXECU
T
I
V
E
D
R
I
V
ETRAVELERS WAYSFSFSFSFSFSFSF
SF
SF SF SF SF SF SF
SF
SF
SF
SFSFSFSFSFSFSFSF
SF
SF
SF
SF
SF SF
SF SF
SF
SF
SF SF
SF
SFSFSFDRAINAGE AREA #2
±1.87 AC DIST. AREA TO ±873 LF SF
DRAINAGE AREA #3
±0.71 AC DIST. AREA TO ±482 LF SF
PROP. CLEAN WATER DIVERSION #2
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #3
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #4
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLETB W E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-202 DEMO & PHASE I EROSION CONTROL PLAN - BJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-202
DEMO & PHASE
I EROSION
CONTROL PLAN
- B
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-201DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
S69°59'18"W
717
.95
'LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LODLODLODLODLODTACK
E
T
T
C
O
U
R
T
EXECUTIVE DRIVETRAVE
L
E
R
S
W
A
YSFSFSF
SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SFSFSFSFSFSF
SF
SF
SF
SF
SF
SF SF SF SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #2
±1.87 AC DIST. AREA TO ±873 LF SF
DRAINAGE AREA #3
±0.71 AC DIST. AREA TO ±482 LF SF
DRAINAGE AREA #4
±2.52 AC DIST. AREA TO ±2,100 LF SF
DRAINAGE AREA #5
±0.50 AC DIST. AREA TO ±842 LF SF
PROP. CLEAN WATER DIVERSION #3
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #2
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. CLEAN WATER DIVERSION #3
ACF DOUBLE STRAW LINED BC WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-203 DEMO & PHASE I EROSION CONTROL PLAN - CJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-203
DEMO & PHASE
I EROSION
CONTROL PLAN
- C
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-204DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD
LOD LOD LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY
SF
SF
SF
SF
SF
SF
SF
SF
SF SF SF SF
SF SF
SF
SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF
SF SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #4
±2.52 AC DIST. AREA TO ±2,100 LF SF
DRAINAGE AREA #5
±0.50 AC DIST. AREA TO ±842 LF SF
PROP. CLEAN WATER DIVERSION #5
ACF DOUBLE STRAW LINED WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-204 DEMO & PHASE I EROSION CONTROL PLAN - DJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-204
DEMO & PHASE
I EROSION
CONTROL PLAN
- D
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-205MATCHLINE - SHEETC-203DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
N73°23'50"E
659.07
'
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLOD
LODLODLODLODLODLO
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
SF SF SF SF SF SF SF SF SF SF SF
SF SF SF SF SF SF SF SF SF SF SF SF SF
SF
SFSFSFSFSFS
F
SFSFSFDRAINAGE AREA #4
±2.52 AC DIST. AREA TO ±2,100 LF SF
PROP. CLEAN WATER DIVERSION #5
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #6
ACF DOUBLE STRAW LINED
PROP. SILT
FENCE OUTLET
PROP. SILT
FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-205 DEMO & PHASE I EROSION CONTROL PLAN - EJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-205
DEMO & PHASE
I EROSION
CONTROL PLAN
- E
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-204DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD LODLOD
LOD
LOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
L
O
D
L
O
D
LO
D
LO
D
LO
D
HOPELAND DRIVE
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
AREA
427,379 SF
OR
9.81 AC.9.8
1
A
C
.SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF
SF SFSF
SF
SF SF
SF SFSF SF SF SF SF SF SF SF SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
S
F
SF
SF
SF
SF
DRAINAGE AREA #6
±2.91 AC DIST. AREA TO ±2,350 LF SF
PROP. CLEAN WATER DIVERSION #7
ACF DOUBLE STRAW LINED
PROP. INLET
PROTECTION (TYP.)
PROP. CONC. WASHOUT
PROP. CONSTR. ENTRANCE
51.2'
29
'WE
SNAD83NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-206 DEMO & PHASE I EROSION CONTROL PLAN - FJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-206
DEMO & PHASE
I EROSION
CONTROL PLAN
- F
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-207DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD
L
O
D
LODLODLODLODLODLODLODLOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD LOD
LOD
LOD LOD LOD LODLODLODLODLODLODLODHOPELAND DR
I
V
E WETLANDSAREA427,379 SFOR9.81 AC.WETLANDS
AREA
427,379 SF
OR
9.81 AC.
SF
SF
SF
SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSF
SFSFSFSFSFSFSFSF
SF
SF SF SF SF SF
SF
SF SF
SF
SF
SF
SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #6
±2.91 AC DIST. AREA TO ±2,350 LF SF DRAINAGE AREA #7±0.25 AC DIST. AREA TO ±280 LF SFPROP. CLEAN WATER DIVERSION #7
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #8
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET PROP. CLEAN WATER DIVERSION #8ACF DOUBLE STRAW LINEDW E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-207 DEMO & PHASE I EROSION CONTROL PLAN - GJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-207
DEMO & PHASE
I EROSION
CONTROL PLAN
- G
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-206M
A
T
C
H
L
I
N
E
-
S
H
E
E
T
C-
2
0
8
DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
LODLODLODLODLODLOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LODLODLO
D
LO
D
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
L
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODHOPELAND DRIVERAMSHEAD ROADWETLANDS
AREA
17,139 SF
OR
0.39 AC.
WETLANDS
AREA
427,379 SF
OR
9.81 AC.
S
F
SF
SF
SF
SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSF
SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #7
±0.25 AC DIST. AREA TO ±280 LF SF
DRAINAGE AREA #8
±0.78 AC DIST. AREA TO ±280 LF SF
DRAINAGE AREA #9
±0.50 AC DIST. AREA TO ±550 LF SFDRAINAGE AREA #8±0.78 AC DIST. AREA TO ±280 LF SFPROP. CLEAN WATER DIVERSION #8ACF DOUBLE STRAW LINEDPROP. CLEAN WATER DIVERSION #9ACF DOUBLE STRAW LINEDPROP. CLEAN WATER DIVERSION #10ACF DOUBLE STRAW LINEDPROP. CLEAN WATER DIVERSION #8
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #9
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #10
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-208 DEMO & PHASE I EROSION CONTROL PLAN - HJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-208
DEMO & PHASE
I EROSION
CONTROL PLAN
- H
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-207DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
HOPELAND DRIVERIDGEWOOD COURTRAMSHEAD ROADRAMSHEAD ROAD
SF SF SF SF SF SF SF SF SF SF SF SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #8
±0.78 AC DIST. AREA TO ±280 LF SF
DRAINAGE AREA #10
±5.01 AC DIST. AREA TO ±4,375 LF SF
PROP. CLEAN WATER DIVERSION #9
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #10
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #11
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #14
ACF DOUBLE STRAW LINED WESNAD83NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-209 DEMO & PHASE I EROSION CONTROL PLAN - IJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-209
DEMO & PHASE
I EROSION
CONTROL PLAN
- I
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-210DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
WESNAD83NAD83LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
DPAXTON PLACEPISGAH COURTRAMSHEAD ROADRAMSHEAD ROAD SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #10
±5.01 AC DIST. AREA TO ±4,375 LF SF
PROP. CLEAN WATER DIVERSION #11
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #12
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #13
ACF DOUBLE STRAW LINED MATCHLINE
-
SHEETC-211DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-210 DEMO & PHASE I EROSION CONTROL PLAN - JJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-210
DEMO & PHASE
I EROSION
CONTROL PLAN
- J
OAP-0
1"=40'
0 40102040MATCHLINE - SHEETC-209DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRAMSHEAD ROA
D
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
SF
SF
SF
SF
SF
SF
SF SF SF SF SF SF
SF
SF
SF
SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #10
±5.01 AC DIST. AREA TO ±4,375 LF SF
PROP. CLEAN WATER DIVERSION #11
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. SILT FENCE OUTLET WESNAD83NAD
83
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-211 DEMO & PHASE I EROSION CONTROL PLAN - KJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-211
DEMO & PHASE
I EROSION
CONTROL PLAN
- K
OAP-0MATCHLINE - SHEETC-2101"=40'
0 40102040
DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD
LOD
LO
D
LO
D
LOD
LOD
LOD
LOD
PISGAH COURT
RAMSHEAD ROADSFSFSFSFSFSFSFSF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #10
±5.01 AC DIST. AREA TO ±4,375 LF SF
PROP. CLEAN WATER DIVERSION #12
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-212 DEMO & PHASE I EROSION CONTROL PLAN - LJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-212
DEMO & PHASE
I EROSION
CONTROL PLAN
- L
OAP-0
1"=40'
0 40102040
DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
LODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPAXTON PLACE
RAMSHEAD ROADWETLANDS
AREA
123,793 SF
OR
2.84 AC.SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #10
±5.01 AC DIST. AREA TO ±4,375 LF SF
PROP. CLEAN WATER DIVERSION #13
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-213 DEMO & PHASE I EROSION CONTROL PLAN - MJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-213
DEMO & PHASE
I EROSION
CONTROL PLAN
- M
OAP-0
1"=40'
0 40102040
DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
S89°56'20"E 1569.80'N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 ACLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LODLOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRIDGEWOOD COURT
RAMSHEAD ROADWETLANDS
AREA
31,240 SF
OR
0.72 AC.SFSFSFSFSFSFSFSFSFSFSFSFSF SF SF
SF
SF
SFSF SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFDRAINAGE AREA #10
±5.01 AC DIST. AREA TO ±4,375 LF SF
PROP. CLEAN WATER DIVERSION #14
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OAP-0----->LAYOUT: C-214 DEMO & PHASE I EROSION CONTROL PLAN - NJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-214
DEMO & PHASE
I EROSION
CONTROL PLAN
- N
OAP-0
1"=40'
0 40102040
DEMOLITION/REMOVAL NOTE
D
S
C
SL
W
E
G
OH
T
OR 516.4TC 516.4
TYPICAL NOTE TEXT
DEMOLITION / REMOVAL
LEGEND
SAN
#
STM
#
X
EASEMENT
LINE
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
S
WV
WM
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE I EROSION CONTROL CONSTRUCTION SEQUENCE:
1.OBTAIN A LAND DISTURBANCE PERMIT.
2.POST REQUIRED DOCUMENTS NEAR THE PLANNED CONSTRUCTION EXIT, AND WITHIN EASY ACCESS TO THE GENERAL PUBLIC
WITHOUT ENTERING THE SITE.
3.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE/FLAG THE LOD (WHERE
STAKING IS NOT POSSIBLE/PRACTICAL, THE LOD MUST BE CONSPICUOUSLY AND PROMINENTLY MARKED TO DENOTE THE
BOUNDARY). LOD MUST REMAIN CONSPICUOUSLY MARKED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. NO
DISTURBANCE IS TO TAKE PLACE BEYOND THE LOD.
4.INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY DIVERSIONS, SILT FENCE, CONCRETE WASHOUT AREA, OR OTHER MEASURES
AS SHOWN ON THE APPROVED PLAN. CLEAR ONLY AS NECESSARY TO INSTALL THESE DEVICES. SEED TEMPORARY DIVERSIONS
AND BERMS IMMEDIATELY AFTER CONSTRUCTION.
5.WHERE THERE IS EXISTING PAVEMENT, PAVEMENT TO BE REMOVED BEFORE THE REST OF THE SITE IS GRADED AND SILT FENCE TO
BE INSTALLED IMMEDIATELY.
6.INSTALL SILT FENCE AROUND THE SITE AS SHOWN IN PHASE I. CLEAR THE MINIMUM AMOUNT NECESSARY TO INSTALL THE SILT
FENCE.
7.BEGIN STRIPPING THE SITE (COMPLETE CLEARING AND GRUBBING TO THE EXTENT PRACTICAL TO MINIMIZE THE AMOUNT OF AREA
DISTURBED AT ANY POINT IN TIME.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL PRECEDING
BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING, ANY CHANGES IN THE
ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
ANNOTATION LEGEND:
TBR:TO BE REMOVED
TR:TO REMAIN
TBRL:TO BE RELOCATED
TBA:TO BE ABANDONED
TBRP:TO BE REPLACED
TBM:TO BE MODIFIED
DEMOLITION NOTES:
1.THIS PLAN REFERENCES SURVEY AND INFORMATION BY:
BOHLER ENGINEERING
4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
2.CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT OF 1970, (29 U.S.C. 651 ET SEQ.), AS AMENDED AND
ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME.
3.BOHLER ENGINEERING NC, PLLC HAS NO CONTRACTUAL, LEGAL,
OR OTHER RESPONSIBILITY FOR JOB SITE SAFETY OR JOB SITE
SUPERVISION, OR ANYTHING RELATED TO SAME.
4.THE DEMOLITION PLAN IS INTENDED TO PROVIDE GENERAL
INFORMATION, ONLY, REGARDING ITEMS TO BE DEMOLISHED
AND/OR REMOVED. THE CONTRACTOR MUST ALSO REVIEW THE
OTHER SITE PLAN DRAWINGS AND INCLUDE IN DEMOLITION
ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE
CONSTRUCTION OF THE NEW SITE IMPROVEMENTS.
5.CONTRACTOR MUST RAISE ANY QUESTIONS CONCERNING THE
ACCURACY OR INTENT OF THESE PLANS OR SPECIFICATIONS,
CONCERNS REGARDING THE APPLICABLE SAFETY STANDARDS,
OR THE SAFETY OF THE CONTRACTOR OR THIRD PARTIES IN
PERFORMING THE WORK ON THIS PROJECT, WITH BOHLER
ENGINEERING, IN WRITING, AND RESPONDED TO BY BOHLER, IN
WRITING, PRIOR TO THE INITIATION OF ANY SITE ACTIVITY AND
ANY DEMOLITION ACTIVITY. ALL DEMOLITION ACTIVITIES MUST BE
PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS, RULES,
REQUIREMENTS, STATUTES, ORDINANCES AND CODES.
6.PRIOR TO STARTING ANY DEMOLITION, CONTRACTOR IS
RESPONSIBLE FOR/TO: OBTAINING ALL REQUIRED PERMITS AND
MAINTAINING THE SAME ON SITE FOR REVIEW BY THE ENGINEER
AND OTHER PUBLIC AGENCIES HAVING JURISDICTION
THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK AND
DEMOLITION WORK.
7.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AS
INDICATED ON THE PLAN IS APPROXIMATE. FIELD LOCATE ALL
UNDERGROUND EXISTING UTILITIES LOCATED IN THE AREA OF
WORK PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL
"NORTH CAROLINA 811" PRIOR TO CONSTRUCTION FOR
ASSISTANCE IN LOCATING EXISTING UNDERGROUND UTILITIES.
SUBSURFACE FEATURES ARE SHOWN IN AN APPROXIMATE
LOCATION. CONTRACTOR IS RESPONSIBLE FOR SUBSURFACE
UTILITY EXPLORATION TO DETERMINE UNDERGROUND UTILITY
LOCATIONS AND DEPTH.
8.ALL SIDEWALKS AND CURB AND GUTTER SECTIONS SHALL BE
REMOVED BY SAWCUTTING THE NEAREST CONTROL JOINT AWAY
FROM THE LOCATION DESIGNATED FOR REMOVAL ON THE PLANS.
EXISTING PAVEMENT SHALL BE SAWCUT IN ALL LOCATIONS
WHERE ABUTTING NEW PAVEMENT OR CONCRETE.
9.COORDINATE ALL UTILITY REMOVAL, RELOCATION, &
ABANDONMENT WITH THE APPROPRIATE UTILITY SERVICE
PROVIDER. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL
UTILITY SERVICES TO ADJACENT PROPERTIES DURING ALL
PHASES OF CONSTRUCTION. ALL UTILITIES TO BE DEMOLISHED
SHALL BE TAKEN BACK TO R.O.W.
10.THE CRZ OF SPECIMEN TREES SHALL BE PROTECTED WITH 6-
FOOT CHAIN LINK TREE SAVE FENCING SPACED 6 FEET ON
CENTER WITH METAL SUPPORT POSTS AND TREE SAVE SIGNAGE.
INSTALLATION OF THE TREE SAVE FENCE WILL INVOLVE NO
TRENCHING. 3 INCHES OF ORGANIC MULCH OVER THE CRZ AND
AN ABOVE GROUND IRRIGATION SYSTEM.
11.TREE SAVE FENCE FOR THE ENTIRE SITE MUST BE INSTALLED,
INSPECTED AND APPROVED PRIOR TO THE INSTALLATION OF
EROSION CONTROL MEASURES. NO LAND DISTURBANCE OR
DEMOLITION IS ALLOWED BEFORE TREE SAVE FENCING HAS BEEN
INSPECTED AND APPROVED BY COMMUNITY DEVELOPMENT
DIRECTOR.
12.ALL EXISTING TREES, SPECIMEN, AND NON-SPECIMEN, COUNTED
FOR EDF CREDITS MUST BE FULLY PRESERVED DURING
INDIVIDUAL LOT PERMITTING.
LOD
LOD
LODLOD LOD LOD LODLODLODLODLOD
LODLODLOD LOD LODLODLOD LODLOD
LODLODLOD LOD LOD LODLOD LODL
O
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD
LOD
LOD
LOD LOD LODLODLODLOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD
LOD
LOD LODLODLODLODLODLODLODLODLO
D
LOD
LOD LOD
LOD LOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLO
D
LODLODLODLODLODLOD50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X5
0
'BUILD
I
N
G
ENV
E
L
O
P
E
2,50
0
S
F
50'X50'
BUILDING
ENVELOPE
2,500 SF 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE
2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUIL
DI
NG
ENVELOPE
2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDIN
G
ENVELOP
E
2,500 SF
50'X50
'
BUILDI
N
G
ENVEL
O
P
E
2,500
S
F
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE
2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X6
0
'BUIL
D
I
N
G
ENVE
L
O
P
E
3,600
S
F
60'
X
6
0
'
BU
I
L
D
I
N
G
E
N
V
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOP
E
3,600 SF
60'X60'BUILDI
N
G
ENVELOP
E3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
50'X50'BUILDINGENVELOPE
2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'
X
6
0
'
BUI
L
D
I
N
G
ENV
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
6
0
'
X
6
0
'
BU
I
L
D
I
N
G
E
N
V
E
LO
P
E
3,
6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDI
N
G
ENVELO
P
E
3,600 S
F
60
'
X
6
0
'
BU
I
L
D
I
N
G
E
N
V
E
LO
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60
'BUILD
I
N
G
ENVEL
O
P
E
3,600
S
F 60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDI
NG
ENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDI
N
G
ENVELO
P
E
3,600 S
F
50'X50'
BUILDING
ENVELOPE
2,500 SF
60'X6
0'
BUILDIN
G
ENVE
L
OPE
3,600 SF 60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE3,600 SF
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X6
0'
BUILDI
N
G
ENVEL
OPE
3,600
S
F
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELO
P
E
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDIN
G
ENVELOP
E
3,600 SF
60'X60'
BUILDIN
G
ENVEL
O
P
E
3,600
S
F
60'X60'BUILDING
ENVELOPE3,600 SF
60'X
6
0'BUILDIN
G
ENVELOPE3,600 SF
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
SF 60'X60'BUILDING
ENVEL
OPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X50'
BUILDING
ENVELOPE
2,500 SF
60'X60'BUILDIN
GENVELO
P
E
3,600 S
F
60'X60'BUILDINGENVELOPE3,600 SF
SFSFSFSF
SF SF
SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSF
SF
SFSFSFSFSFSFSF
SF
SFSFSFSFSFSFSFSF
SF
SF
SF SF SFSFSFSF SF
SF SFSFSFSFSFSFSFSFSFSFSF
SF SFS
F
SFSF SF SF SFS
F
SFSFSF SF SFSFSFSFSFSF SF SF SFSFSFSFSFSFSFSFA B
G
CDEFHIKNMLW E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-300 OVERALL PH2 EROSION PLANJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-300
OVERALL PH2
EROSION PLAN
OBP-0
1"=200'
0 20050100200
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD
LOD
LOD LODLODLOD
LOD
LOD
LOD LODLOD
LODKINGWOOD COURTEXECU
T
I
V
E
D
R
I
V
E
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
31
5 315320325
314 3143
1
6317318319321322323324326327328329 BUILDING
ENVELOP
E
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 9.0 FT
W1 = 4.5 FT
W2 = 14.9 FT
d50 = 8 IN
T = 12 IN
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS II
L = 40.0 FT
W1 = 12.0 FT
W2 = 58.2 FT
d50 = 14 IN
T = 21 IN
SF
SF
SF
SF
SF
SF
SF
SF
SF SF SF SF SF SF
SF
SF
SF
SF
SF
PROP. CLEAN WATER DIVERSION #1
ACF DOUBLE STRAW LINED
PROP. CONC. WASHOUT
PROP. CONSTR. ENTRANCE
52.
5
'37'W E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-301 SITE & PHASE II EROSION CONTROL PLAN - AJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-301
SITE & PHASE
II EROSION
CONTROL PLAN
- A
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-302EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
LODLOD
LOD
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD LOD
LOD
LOD
LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTACKETT COURTEXECU
T
I
V
E
D
R
I
V
ETRAVELERS WAY3203203253253163173173
1
8
31831
9
319321321322322323323324324326326327327328
328
330330
3
2
8
328
329
3
2
9
50'X50'
BUILDING
ENVELOP
E
2,500 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 SF
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 S
F
50'X50
'
BUILDI
N
G
ENVEL
O
P
E
2,500
S
F
PROP 35
'
F
R
O
N
T
S
E
T
B
A
C
K PROP 25'' REAR SETBACKPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS A
L = 5.0 FT
W1 = 3.8 FT
W2 = 9.5 FT
d50 = 4 IN
T = 6 IN
SFSFSFSFSFSFSF
SF
SF SF SF SF SF SF
SF
SF
SF
SFSFSFSFSFSFSFSF
SF
SF
SF
SF
SF SF
SF SF
SF
SF
SF SF
SF
SFSFSFPROP. CLEAN WATER DIVERSION #2
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #3
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #4
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
W E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-302 SITE & PHASE II EROSION CONTROL PLAN - BJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-302
SITE & PHASE
II EROSION
CONTROL PLAN
- B
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-301CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
S69°59'18"W
717
.95
'LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LODLODLODLODLODTACK
E
T
T
C
O
U
R
T
EXECUTIVE DRIVETRAVE
L
E
R
S
W
A
Y
320
325
319
321
322
323
324
326
327
3
2
8
325330
33033032632732832832832932932933133133133233350'X50
'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SFPROP 35'
F
R
O
N
T
S
E
T
B
A
C
KSFSFSF
SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SFSFSFSFSFSF
SF
SF
SF
SF
SF
SF SF SF SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #3
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #2
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. CLEAN WATER DIVERSION #3
ACF DOUBLE STRAW LINED WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-303 SITE & PHASE II EROSION CONTROL PLAN - CJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-303
SITE & PHASE
II EROSION
CONTROL PLAN
- C
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-304CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD
LOD LOD LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY
300305310315320325
297298299301302303304306307308309311312313314316
317
318319321322323324 50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFSF
SF
SF
SF
SF
SF
SF
SF
SF SF SF SF
SF SF
SF
SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF
SF SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #5
ACF DOUBLE STRAW LINED WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-304 SITE & PHASE II EROSION CONTROL PLAN - DJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-304
SITE & PHASE
II EROSION
CONTROL PLAN
- D
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-305MATCHLINE - SHEETC-303CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
N73°23'50"E
659.07
'
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLOD
LODLODLODLODLODLO
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY
WETLANDS
AREA
848,034 SF
OR
19.47 AC.2752802852902952
7
4276277278279281282283284286287288289291292293294296
27
5
50'X
5
0
'
BUIL
D
I
N
G
ENV
E
L
O
P
E
2,50
0
S
F50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFBUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS I
L = 16.0 FT
W1 = 6.0 FT
W2 = 24.5 FT
d50 = 10 IN
T = 15 IN
SF SF SF SF SF SF SF SF SF SF SF
SF SF SF SF SF SF SF SF SF SF SF SF SF
SF
SFSFSFSFSFS
F
SFSFSFPROP. CLEAN WATER DIVERSION #5
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #6
ACF DOUBLE STRAW LINED
PROP. SILT
FENCE OUTLET
PROP. SILT
FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-305 SITE & PHASE II EROSION CONTROL PLAN - EJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-305
SITE & PHASE
II EROSION
CONTROL PLAN
- E
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-304CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD LODLOD
LOD
LOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
L
O
D
L
O
D
LO
D
LO
D
LO
D
HOPELAND DRIVE
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
AREA
427,379 SF
OR
9.81 AC.9.8
1
A
C
.
305310315320325330335340
302
303
304
306
3073083093113123133143163173183193213223233243263273283293
31
33233333433633733833934134234360'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X6
0
'
BUIL
D
I
N
G
ENVE
L
O
P
E
3,60
0
S
F
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF 60'X
6
0
'
BUIL
D
I
N
G
ENV
E
L
O
P
E
3,60
0
S
F
60
'
X
6
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600 S
F
50
'
X
5
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
2,
5
0
0
S
F
EN
V
E
L
O
P
E
2,
5
0
0
S
FSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF
SF SFSF
SF
SF SF
SF SFSF SF SF SF SF SF SF SF SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
S
F
SF
SF
SF
SF
PROP. CLEAN WATER DIVERSION #7
ACF DOUBLE STRAW LINED
PROP. INLET
PROTECTION (TYP.)
PROP. CONC. WASHOUT
PROP. CONSTR. ENTRANCE
51.2'
29
'WE
SNAD83NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-306 SITE & PHASE II EROSION CONTROL PLAN - FJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-306
SITE & PHASE
II EROSION
CONTROL PLAN
- F
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-307CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD
L
O
D
LODLODLODLODLODLODLODLOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD LOD
LOD
LOD LOD LOD LODLODLODLODLODLODLODHOPELAND DR
I
V
E WETLANDSAREA427,379 SFOR9.81 AC.WETLANDS
AREA
427,379 SF
OR
9.81 AC.
280
2852902953002
7
7
27
8
279
281282
283
284
28628728828929129229329429629729829930130230360'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
S
F60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
60'X60'
BUILDING
ENVELOPE
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF 60'X60'BUIL
DI
N
G
ENVEL
OPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X50'
BUILDING
ENVELOPE
2,500 SF
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 9.0 FT
W1 = 4.5 FT
W2 = 14.9 FT
d50 = 8 IN
T = 12 IN
SF
SF
SF
SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSF
SFSFSFSFSFSFSFSF
SF
SF SF SF SF SF
SF
SF SF
SF
SF
SF
SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #7
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #8
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET PROP. CLEAN WATER DIVERSION #8ACF DOUBLE STRAW LINEDW E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-307 SITE & PHASE II EROSION CONTROL PLAN - GJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-307
SITE & PHASE
II EROSION
CONTROL PLAN
- G
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-306M
A
T
C
H
L
I
N
E
-
S
H
E
E
T
C-
3
0
8
CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
LODLODLODLODLODLOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LODLODLO
D
LO
D
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
L
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODHOPELAND DRIVERAMSHEAD ROADWETLANDS
AREA
17,139 SF
OR
0.39 AC.
WETLANDS
AREA
427,379 SF
OR
9.81 AC.
2
7
5275280274
27
4
27
6276276277
277
2
77
2
7
8
278
2
7
8279281282279
276280
278
279
281
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF6
0
'
X
6
0
'
60
'
X
6
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600 S
F
60'X60'
BUILDING
ENVELOPE
3,600 SF
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 IN
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS I
L = 40.0 FT
W1 = 15.0 FT
W2 = 61.2 FT
d50 = 10 IN
T = 15 IN
S
F
SF
SF
SF
SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSF
SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #8
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #9
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #10
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-308 SITE & PHASE II EROSION CONTROL PLAN - HJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-308
SITE & PHASE
II EROSION
CONTROL PLAN
- H
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-307CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
HOPELAND DRIVERIDGEWOOD COURTRAMSHEAD ROADRAMSHEAD ROAD
275 274276
277
278
278 2792
8
0
28
5 29
0
2
7
8
2
7
9
2
8
1
2
8
2
2
8
3
2
8
4
28
6
28
7
28
8 28
9 291 292 293
285
281
282
283
284286 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFENVELOPE3,600 SFENVELOPE3,600 SFENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFSF SF SF SF SF SF SF SF SF SF SF SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #9
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #10
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #11
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #14
ACF DOUBLE STRAW LINED WESNAD83NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-309 SITE & PHASE II EROSION CONTROL PLAN - IJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-309
SITE & PHASE
II EROSION
CONTROL PLAN
- I
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-310CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
WESNAD83NAD83LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
DPAXTON PLACEPISGAH COURTRAMSHEAD ROADRAMSHEAD ROAD
2
9
5 300305310
315
29
4
2
9
6 297 29829930130230330430630730
8
309
311
312
313
314
316
305
302
303
304
306
307
30
8
29
0
28
9
291
29
2293 50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SFBUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #11
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #12
ACF DOUBLE STRAW LINED
PROP. CLEAN WATER DIVERSION #13
ACF DOUBLE STRAW LINED MATCHLINE
-
SHEETC-311DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-310 SITE & PHASE II EROSION CONTROL PLAN - JJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-310
SITE & PHASE
II EROSION
CONTROL PLAN
- J
OBP-0
1"=40'
0 40102040MATCHLINE - SHEETC-309CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRAMSHEAD ROA
D
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
3153
20 3253
3
0
33
5
34
0
3
1
1
31
2
313314316317318 319 32132232332432632
7
32
8
32
9 33133233333433
6 337
3
3
8
3
3
9
34
1
342
BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPESF
SF
SF
SF
SF
SF
SF SF SF SF SF SF
SF
SF
SF
SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #11
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. SILT FENCE OUTLET WESNAD83NAD
83
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-311 SITE & PHASE II EROSION CONTROL PLAN - KJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-311
SITE & PHASE
II EROSION
CONTROL PLAN
- K
OBP-0MATCHLINE - SHEETC-3101"=40'
0 40102040
CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD
LOD
LO
D
LO
D
LOD
LOD
LOD
LOD
PISGAH COURT
RAMSHEAD ROAD305310
304
306
30
7 3083093113
0
0
30530130230330430630730830060'
X
6
0
'
BUI
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 INSFSFSFSF
SFSFSFSF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #12
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-312 SITE & PHASE II EROSION CONTROL PLAN - LJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-312
SITE & PHASE
II EROSION
CONTROL PLAN
- L
OBP-0
1"=40'
0 40102040
CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
LODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPAXTON PLACE
RAMSHEAD ROADWETLANDS
AREA
123,793 SF
OR
2.84 AC.
295
300
2
9
1
2
9
2
2
9
3 294296
297
298
299
29028628728828929129229350'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60
'BUI
LD
INGENVE
LOPE3,600
SF
60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 INSFSFSFSFSFSF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #13
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-313 SITE & PHASE II EROSION CONTROL PLAN - MJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-313
SITE & PHASE
II EROSION
CONTROL PLAN
- M
OBP-0
1"=40'
0 40102040
CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
S89°56'20"E 1569.80'N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 ACLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LODLOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRIDGEWOOD COURT
RAMSHEAD ROADWETLANDS
AREA
31,240 SF
OR
0.72 AC.28529028628728828927528028527627727827928128228328428660'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60
'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 IN
SFSFSFSFSFSFSFSFSFSFSFSFSF SF SF
SF
SF
SFSF SF SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPROP. CLEAN WATER DIVERSION #14
ACF DOUBLE STRAW LINED
PROP. SILT FENCE OUTLET WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-OBP-0----->LAYOUT: C-314 SITE & PHASE II EROSION CONTROL PLAN - NJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-314
SITE & PHASE
II EROSION
CONTROL PLAN
- N
OBP-0
1"=40'
0 40102040
CURB AND GUTTER
SPILL CURB TRANSITION CURB
DEPRESSED CURB AND GUTTER
X
SITE LEGEND
X
CONCRETE CURB &
GUTTER
UTILITY POLE
WITH LIGHT
POLE
LIGHT
TRAFFIC
LIGHT
UTILITY
POLE
TYPICAL
LIGHT
ACORN
LIGHT
TYPICAL
SIGN
PARKING
COUNTS
EROSION CONTROL LEGEND
LIMIT OF TRIBUTARY AREAS
SILT FENCE
LIMITS OF DISTURBANCE
SF SF
LOD LOD
PROP. CONSTR. ENTRANCE
COMPOST FILTER SOCK
TEMPORARY SOIL STOCKPILE
INLET PROTECTION
BAFFLE
HAY BALE CHECK DAMS
DIVERSION DITCH
SUPER SILT FENCESSFSSF
SILT FENCE OUTLET
PHASE II EROSION CONTROL CONSTRUCTION SEQUENCE:
1.BEGIN CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE.
2.CLEAR AND GRUB SITE TO THE EXTENT POSSIBLE THAT MINIMIZES THE AMOUNT OF AREA DISTURBED AT ANY GIVEN TIME.
3.BRING SITE TO FINAL GRADE AND INSTALL DRAINAGE PIPES AS SHOWN IN THE PHASE II SEDIMENT AND EROSION CONTROL
PLANS. PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS, OR OTHER APPROVED MEASURES
AS SHOWN ON THE PLAN. BEGIN CONSTRUCTION ACTIVITIES.
4.TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT
LAND DISTURBING ACTIVITY.
5.STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND
MULCH DENUDED AREAS PER GROUND STABILIZATION TIME FRAMES.
6.REMOVE TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT TRAPS, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE
AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS VELOCITY DISSIPATERS, SHOULD NOW BE
INSTALLED.
7.CONTRACTOR SHALL NOT DEMOBILIZE FROM SITE UNTIL ENTIRE SITE HAS BEEN FULLY STABILIZED.
THE ESTIMATED DATES OF IMPLEMENTATION OF POLLUTION CONTROL MEASURES SHALL BE DOCUMENTED BY THE CONTRACTOR.
NOTE: THE GENERAL CONTRACTOR MAY COMPLETE CONSTRUCTION-RELATED ACTIVITIES CONCURRENTLY, ONLY IF ALL
PRECEDING BMPS AND STABILIZATION ACTIVITIES HAVE BEEN COMPLETELY INSTALLED. THE CEC MUST APPROVE, IN WRITING,
ANY CHANGES IN THE ABOVE IMPLEMENTATION SEQUENCE, BEFORE THEIR IMPLEMENTATION BEGINS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SITE NOTES
1.OWNER / EQUITABLE DEVELOPER / APPLICANT:
OAKMONT DEVELOPMENT PARTNERS, LLC.
5112 PINE BIRCH DRIVE
RALEIGH, NC 27606
PHONE: (919) 793-5237
CONTACT: PAT MCKEE
EMAIL: PAT@MCKEEHOMESNC.COM
2.ALL SIDEWALKS, STRIPING AND SIGNAGE TO BE
ADA AND CODE COMPLIANT.
3.ZONING DATA:
PARCEL ID: 0507-53-6396.0000
TOTAL PARCEL AREA: 325.12 AC (INCLUDES LOT
PREVIOUSLY SUBVIDIDED DURING PHASE I AND
PHASE II.)
EXISTING ZONING: RA-20R (RESIDENTIAL/
AGRICULTURAL DISTRICT)
EXISTING USE: UNDEVELOPED
PROPOSED USE: SINGLE FAMILY HOMES
4.THIS PLAN IS BASED ON THE FOLLOWING:
BOUNDARY AND TOPOGRAPHIC SURVEY
BOHLER ENGINEERING4130 PARKLAKE AVE, SUITE 130
RALEIGH, NC 27612
FIELD DATED: 10/21/2020
5.THE IMPROVEMENTS FOR THIS PROJECT INCLUDE
THE CONSTRUCTION OF ±9,430 LF OF NEW
ROADWAYS EXTENDING FROM THE EXISTING
TERMINUSES OF EXECUTIVE DRIVE AND
HOPELAND DRIVE. AN ASSOCIATED WATER
DISTRIBUTION SYSTEM AND STORMWATER
DRAINAGE SYSTEM ARE ALSO PROPOSED ON THESITE.
6.NO GRADING IS DONE WITHIN THE 100-YEAR
FLOODPLAIN ELEVATION.
7.ALL TRAFFIC CONTROL SIGNS THAT ARE
REMOVED OR DAMAGED MUST BE REINSTALLED
OR REPLACED. ALL SIGNS MUST BE REINSTALLED
TO THE STANDARDS IN THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
LODLO
D
LODLOD LOD LOD LODLODLODLODLOD
LODLODLOD LOD LODLODLOD LODLOD
LODLODLOD LOD LOD LODLOD LODL
O
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD
LOD
LOD
LOD
LOD LODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD
LOD
LOD LODLODLODLODLODLODLODLODLO
D
LOD
LOD LOD
LOD LOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLO
D
LODLODLODLODLODLOD50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X5
0
'BUIL
D
I
N
GENVE
L
O
P
E
2,50
0
S
F
50'X50'
BUILDING
ENVELOPE
2,500 SF 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDIN
G
ENVELOPE2,500 SF
50'X50'BUILDING
ENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'
BUILDI
NG
ENVELOPE2,500 SF
50'X50'
BUILDI
N
G
ENVEL
O
P
E
2,500 S
F
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X6
0
'BUILDI
N
GENVE
L
O
P
E
3,600
S
F
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOP
E
3,600 SF
60'X60'BUILDIN
GENVELOP
E
3,600 S
F
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
50'X50'BUILDINGENVELOP
E
2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'
X
6
0
'
BUI
L
D
I
N
G
ENV
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'
X
6
0
'
B
U
I
L
D
IN
G
E
N
V
E
LO
P
E
3,
6
0
0
S
F60'X60'BUILDIN
G
ENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 SF
6
0
'
X
6
0
'
BU
I
L
D
I
N
G
E
NV
E
LO
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDINGENVELOPE
3,600 SF
60'X6
0
'BUILDI
N
GENVELO
P
E
3,600
S
F 60'X60'BUILDING
ENVEL
OPE
3,600 SF60'X60'BUILDING
ENVEL
OPE
3,600 SF60'X60'BUILDI
NG
ENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDI
N
G
ENVELO
P
E
3,600
S
F
50'X50'
BUILDING
ENVELOPE2,500 SF
60'X60'BUILDI
NG
ENVELO
PE
3,600 S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDINGENVELOPE
3,600 SF
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDI
NG
ENVEL
O
P
E
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELO
P
E
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELO
P
E
3,600 SF
60'X60
'
BUILDI
N
G
ENVEL
O
P
E
3,600
S
F
60'X60'BUILDING
ENVELOPE3,600 SF60'X60'BUILDI
NG
ENVEL
OPE
3,600 SF
60'X6
0'
BUILD
I
N
G
ENVELO
P
E
3,600
S
F
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVELOP
E
3,600
S
F 60'X60'BUILDING
ENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X50'
BUILDING
ENVELOPE
2,500 SF
60'X60'BUILDIN
GENVELO
P
E
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
A B
G
CDEFHIKJNMLW E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-400 OVERALL GRADING AND DRAINAGE PLANJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-400
OVERALL
GRADING AND
DRAINAGE
PLAN
GDP-0
1"=200'
0 20050100200
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD
LOD
LOD LODLODLOD
LOD
LOD
LOD LODLOD
LODKINGWOOD COURTEXECU
T
I
V
E
D
R
I
V
E
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
BUILDING
ENVELOP
E
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 9.0 FT
W1 = 4.5 FT
W2 = 14.9 FT
d50 = 8 IN
T = 12 IN
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS II
L = 40.0 FT
W1 = 12.0 FT
W2 = 58.2 FT
d50 = 14 IN
T = 21 IN
-0
+
0
0
1+0
0
2+00
3+00 4+00
5+00
6+00
0+5
0
1+0
0
1+50
2+50
3+50
4+50
5+50
6+50
315320325314314
316317318319321322323324326
327
328
329
STM
A-22
STM
A-23
STM
A-21.1
STM
A-21
STM
A-20
STM
A-20.1
STM
A-10
259.48' -
18" RCP
@ 2.00%
35.53' -
18" RCP
@ 4.00%
37.00' -
15" RCP
@ 1.50%
187.77' -
15" RCP
@ 3.50%
141.97' -
15" RCP
@ 2.00%
37.00' -
15" RCP
@ 1.50%
37.00' -
15" RCP
@ 4.50%
W E
SNAD83 NAD83DATUM ELEV
305.00
310
320
330
340
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50
-4.00
%
1.50%
PVI STA = 4+48.19
PVI ELEV = 312.07
A.D. = 5.50%
K = 50.00
275.00' VC
BVCS: 3+10.69BVCE: 317.57EVCS: 5+85.69EVCE: 314.13SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
EXECUTIVE DRIVE
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-401 GRADING AND DRAINAGE PLAN - AJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-401
GRADING AND
DRAINAGE
PLAN - A
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-402MATCHLINE - SHEETC-402GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LODLOD
LOD
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD LOD
LOD
LOD
LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTACKETT COURTEXECU
T
I
V
E
D
R
I
V
ETRAVELERS WAY50'X50'
BUILDING
ENVELOP
E
2,500 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 S
F
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 S
F
50'X50
'
BUILDI
N
G
ENVEL
O
P
E
2,500
S
F
PROP 35
'
F
R
O
N
T
S
E
T
B
A
C
K PROP 25'' REAR SETBACKPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS A
L = 5.0 FT
W1 = 3.8 FT
W2 = 9.5 FT
d50 = 4 IN
T = 6 IN
7+00
8+00 9+00
10+00
11+00
12+00
13+00
13+86.0
1
6+50
7+50
8+50
9+50
10+50
11+50
12+50
13+50
1+002+003+001+502+503+50315
32032032532531
6
3
1
7
3173
1
8
31831
9
3193213213223223233233243243263263273273
2
8
328
330330
3
2
8
328
329
3
2
9
STM
A-41
STM
A-50
STM
A-60
STM
A-40
STM
C-30
STM
C-20
STM
A-31
STM
A-30
STM
C-10
29.05' -
15" RCP
@ 1.50%
67.39' -
15" RCP
@ 2.50%
174.28' -
15" RCP
@ 4.50%37.28' -
15" RCP
@ 1.50%
57.47' -
15" RCP
@ 4.00%
37.00' -
15" RCP
@ 8.50%
33.34' -
15" RCP
@ 1.00%
W E
SNAD83 NAD83310
320
330
340
6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00
-5.00
%
5.00%
PVI STA = 10+78.73
PVI ELEV = 332.41
A.D. = -10.00%
K = 30.00
300.00' VC
BVCS: 9+28.73BVCE: 324.91EVCS: 12+28.73EVCE: 324.91PVI STA = 10+78.73
PVI ELEV = 332.41
A.D. = -10.00%
K = 30.00
300.00' VC
BVCS: 9+28.73BVCE: 324.91EVCS: 12+28.73EVCE: 324.91PVI STA = 7+67.76
PVI ELEV = 316.87
A.D. = 3.50%
K = 50.00
175.00' VC
BVCS: 6+80.26BVCE: 315.55EVCS: 8+55.26EVCE: 321.24SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
EXECUTIVE DRIVE
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-402 GRADING AND DRAINAGE PLAN - BJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-402
GRADING AND
DRAINAGE
PLAN - B
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-401MATCHLINE - SHEETC-401GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LODLODLODLODLODTACK
E
T
T
C
O
U
R
T
EXECUTIVE DRIVETRAVE
L
E
R
S
W
A
Y50'X50
'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SFPROP 35'
F
R
O
N
T
S
E
T
B
A
C
K8+009+0010+0011+008+509+5010+500+00
1+00
2+00
3+00
4+00
5+00
6+00
0+50
1+50
2+50
3+50
4+50
5+50
320
325
319
321
322
323
324
326
327
328
325330
330330326327328328328329329329331331331332333
STM
A-41
STM
A-50
STM
A-60
STM
A-40HP 334.04
29.05' -
15" RCP
@ 1.50%
67.39' -
15" RCP
@ 2.50%
174.28' -
15" RCP
@ 4.50%
57.47' -
15" RCP
@ 4.00%WESNAD83
NAD83320
330
340
-1.50%
-4.50
%
3.00%
2.01%-2.01%
-3.00%
DATUM ELEV
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
TACKETT COURT + TRAVELERS WAY
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-403 GRADING AND DRAINAGE PLAN - CJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-403
GRADING AND
DRAINAGE
PLAN - C
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-404MATCHLINE - SHEETC-404GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD
LOD LOD LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY 50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF6+00
7+00
8+00
9+00
10+00
11+00
12+00
13+00
14+00 15+00
6+50
7+50
8+50
9+50
10+50
11+50
12+50
13+50 14+50
300305310315320325
297298299301302303304306307308309311312313314316
317
318319321322323324STM
D-80
STM
D-70
STM
D-61
STM
D-60
STM
D-51
STM
D-5029.00' -
15" RCP
@ 1.50%
299.09' -15" RCP@ 2.00%
299.09' -15" RCP@ 4.00%
284.74' -15" RCP@ 3.00%
29.00' -
15" RCP
@ 1.50%29.00' -
15" RCP
@ 1.50%WESNAD83
NAD83-1.50%
-5.0
0
%
PVI STA = 7+40.94
PVI ELEV = 318.85
A.D. = 3.00%
K = 50.03
150.00' VC
BVCS: 6+65.94BVCE: 322.22EVCS: 8+15.94EVCE: 317.72PVI STA = 13+75.79
PVI ELEV = 299.41
A.D. = 2.50%
K = 50.00
125.00' VC
BVCS: 13+13.29BVCE: 302.54EVCS: 14+38.29EVCE: 297.85PVI STA = 10+92.65
PVI ELEV = 313.57
A.D. = -3.50%
K = 35.73
125.00' VC
BVCS: 10+30.15BVCE: 314.51EVCS: 11+55.15EVCE: 310.446+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
TACKETT COURT + TRAVELERS WAY
290
300
310
320
330
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-404 GRADING AND DRAINAGE PLAN - DJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-404
GRADING AND
DRAINAGE
PLAN - D
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-405MATCHLINE - SHEETC-403MATCHLINE - SHEETC-405MATCHLINE - SHEETC-403GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
N73°23'50"E
659.07
'
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLOD
LODLODLODLODLODLOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
50'X
5
0
'
BUIL
D
I
N
G
ENV
E
L
O
P
E
2,50
0
S
F50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFBUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS I
L = 16.0 FT
W1 = 6.0 FT
W2 = 24.5 FT
d50 = 10 IN
T = 15 IN
15+00 16+00 17+00 18+00 19+00 20+00 20+83.22
15+50 16+50 17+50 18+50 19+50 20+50
2752802852902952
7
4
27627727827928128228328428628728828929129229329429627
5
STM
D-40
STM
D-41
STM
D-31
STM
D-30
STM
D-21
STM
D-20
STM
D-10
TC 275.60
BC 275.10
TC 275.11
BC 274.61
LP 274.29
400.00' -15" RCP@ 3.50%
29.00' -
15" RCP
@ 4.50%29.00' -
18" RCP
@ 2.00%
164.09' -
18" RCP
@ 3.50%
54.32' -
15" RCP
@ 5.00%
129.90' -
24" RCP
@ 5.00%WESNAD83
NAD83280
290
300
310
15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00
-3.00%
-2.50%
-4.00
%
PVI STA = 20+04.22
PVI ELEV = 278.44
A.D. = 1.00%
K = 50.00
50.00' VC
BVCS: 19+79.22BVCE: 279.44EVCS: 20+29.22EVCE: 277.69PVI STA = 16+53.40
PVI ELEV = 292.47
A.D. = -1.50%
K = 33.33
50.00' VC
BVCS: 16+28.40BVCE: 293.09EVCS: 16+78.40EVCE: 291.47SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
TACKETT COURT + TRAVELERS WAY
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-405 GRADING AND DRAINAGE PLAN - EJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-405
GRADING AND
DRAINAGE
PLAN - E
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-404MATCHLINE - SHEETC-404GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD LODLOD
LOD
LOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
L
O
D
L
O
D
LO
D
LO
D
LO
D
HOPELAND DRIVE
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
AREA
427,379 SF
OR
9.81 AC.9.8
1
A
C
.
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X6
0
'
BUIL
D
I
N
G
ENVE
L
O
P
E
3,60
0
S
F
60'X60'
BUILDIN
G
ENVELOP
E
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF 60'X
6
0
'
BUIL
D
I
N
G
ENV
E
L
O
P
E
3,60
0
S
F
60
'
X
6
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600 S
F
50
'
X
5
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
2,
5
0
0
S
F
EN
V
E
L
O
P
E
2,
5
0
0
S
F
0+00
1+00
2+00
3+00
4+00 5+00
6+00
7+00
8+0
0
9+
0
0
10
+
0
0
0+50
1+50
2+50
3+50
4+50
5+50
6+50
7+5
0
8+
5
0
9+
5
0
305310315320325330335340
302
303
304
306307308309311312313314316317318319321322323324326327328329331332333334336337338339341342
343STM
E-80
STM
E-70
STM
E-60
STM
E-50
STM
E-51
STM
E-40
29.00' -
15" RCP
@ 1.50%
245.13' -
15" RCP
@ 5.00%
165.04' -
15" RCP
@ 5.50%
177.31' -
15" RCP
@ 3.00%
29.00' -
15" RCP
@ 1.50%WE
SNAD83NAD83300
310
320
330
340
-5.00
%
PVI STA = 7+76.00
PVI ELEV = 304.93
A.D. = 3.50%
K = 49.98
175.00' VC
BVCS: 6+88.50BVCE: 309.30EVCS: 8+63.50EVCE: 303.62DATUM ELEV
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
HOPELAND DRIVE
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-406 GRADING AND DRAINAGE PLAN - FJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-406
GRADING AND
DRAINAGE
PLAN - F
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-407MATCHLINE - SHEETC-407GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING
UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES,
AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED
ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY
COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF
UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING
UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO
BE USED FOR SLOPES STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH
FIT AND CONTINUOUS GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND
PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER
ENGINEERING. IF THE CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE
PLANS, WITHOUT EXCEPTION, THEN THE CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A
TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL.
CONTRACTOR SHALL APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR
SHALL STABILIZE DISTURBED AREAS IN ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A
HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO
SAME.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM
#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF
ANY EXISTING UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY
TO RETURN IT TO EXISTING CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS
WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE
TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE.
LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE
STATE GENERAL N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION
ACTIVITIES AND THE SPECIAL CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER
POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM
INVERT IN TO INVERT OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE
MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED
GRADING.
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD
L
O
D
LODLODLODLODLODLODLODLOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD LOD LODLODLODLODLODLODLODHOPELAND DR
I
V
E WETLANDSAREA427,379 SFOR9.81 AC.WETLANDS
AREA
427,379 SF
OR
9.81 AC.
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
S
F60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
60'X60'
BUILDING
ENVELOPE
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF 60'X60'BUILDI
N
G
ENVEL
OPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X50'
BUILDING
ENVELOPE
2,500 SF
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 9.0 FT
W1 = 4.5 FT
W2 = 14.9 FT
d50 = 8 IN
T = 12 IN
9+00
10+00
11+00
12+00
13+00
14+00
15+00 16+0017+008+50
9+50
10+50
11+50
12+50
13+50
14+50 15+5016+5017+5028028529029530027
6
277
278
279281282283284286287288289291292293294296297298299301302303STM
E-40
STM
E-30
STM
E-20
STM
E-10
STM
G-24
STM
G-23
STM
G-22
207.51' -
18" RCP
@ 2.50%
29.00' -
15" RCP
@ 1.50%
158.38' -
15" RCP
@ 2.50%
152.85' -
15" RCP
@ 2.50%
29.00' -
15" RCP
@ 1.50%
29.00' -
15" RCP
@ 4.00%
257.01' -
15" RCP
@ 2.00%
W E
SNAD83 NAD83-1.50%
-5.0
0
%
-2.50%
PVI STA = 13+47.26
PVI ELEV = 286.59
A.D. = 2.50%
K = 50.00
125.00' VC
BVCS: 12+84.76BVCE: 289.72EVCS: 14+09.76EVCE: 285.03PVI STA = 10+68.21
PVI ELEV = 300.54
A.D. = -3.50%
K = 35.71
125.00' VC
BVCS: 10+05.71BVCE: 301.48EVCS: 11+30.71EVCE: 297.429+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
HOPELAND DRIVE
280
290
300
310
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-407 GRADING AND DRAINAGE PLAN - GJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-407
GRADING AND
DRAINAGE
PLAN - G
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-408MATCHLINE - SHEETC-406MATCHLINE - SHEETC-406M
A
T
C
H
L
I
N
E
-
S
H
E
E
T
C-
4
0
8
GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LODLODLODLODLODLOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LODLODLO
D
LO
D
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODHOPELAND DRIVERAMSHEAD ROADWETLANDS
AREA
427,379 SF
OR
9.81 AC.60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600 S
F
60'X60'
BUILDING
ENVELOPE
3,600 SF
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 IN
PROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS I
L = 40.0 FT
W1 = 15.0 FT
W2 = 61.2 FT
d50 = 10 IN
T = 15 IN
16
+
0
0
17+00
18+00
19+00
20+00
21+00
22+00
23+00
24+00 24+25.74
16+
5
0
17+50
18+50
19+50
20+50
21+50
22+50
23+500+001+000+501+502
7
52752802742
7
4
27
6276276277277
2
77
2
7
8278 2
7
8
279
279
276280
278
279
281
STM
G-22
STM
G-40
STM
G-41
STM
G-30
STM
G-21
STM
G-21.1
STM
K-30
STM
K-20
STM
G-20.1
STM
G-20
STM
G-10
STM
K-10
LP 275.61
HP 276.36
LP 275.74
152.85' -
15" RCP
@ 2.50%
29.00' -
15" RCP
@ 1.50%
29.71' -
15" RCP
@ 5.50%
56.56' -
24" RCP
@ 1.50%
197.42' -24" RCP@ 2.00%
29.00' -
15" RCP
@ 4.00%
18.95' -
24" RCP
@ 3.96%
53.68' -
15" RCP
@ 2.00%
100.27' -
15" RCP
@ 5.50%
171.86' -
18" RCP
@ 1.50%WESNAD83
NAD83SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
HOPELAND DRIVE
270
280
290
16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50
3.00%-3.00%
PVI STA = 19+55.33
PVI ELEV = 271.39
A.D. = 5.50%
K = 50.00
275.00' VC
BVCS: 18+17.83BVCE: 274.83EVCS: 20+92.83EVCE: 275.52PVI STA = 22+53.87
PVI ELEV = 280.35
A.D. = -6.00%
K = 29.17
175.00' VC
BVCS: 21+66.37BVCE: 277.72EVCS: 23+41.37EVCE: 277.72DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-408 GRADING AND DRAINAGE PLAN - HJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-408
GRADING AND
DRAINAGE
PLAN - H
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-407MATCHLINE - SHEETC-407GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
HOPELAND DRIVERIDGEWOOD COURTRAMSHEAD ROADRAMSHEAD ROAD 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFENVELOPE3,600 SFENVELOPE3,600 SFENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF21+0022+0023+0020+5021+5022+500+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+000+50 1+50 2+50 3+50 4+50 5+50 6+50 7+50 8+50
0+001+000+501+50275274
276
277
278
278 2792
8
0
28
5 29
0
2
7
8
2
7
9
2
8
1
2
8
2
2
8
3
2
8
4
28
6 28
7 28
8
28
9
29
1
29
2 29
3
285
281
282
283
284
28
6
STM
G-50
STM
G-51
STM
G-40
STM
G-41
STM
G-30
450.00' -
18" RCP
@ 1.50%
29.00' -
15" RCP
@ 1.50%
442.75' -
18" RCP
@ 2.50%29.71' -
15" RCP
@ 5.50%
56.56' -
24" RCP
@ 1.50%197.42' -24" RCP@ 2.00%WESNAD83NAD83DATUM ELEV
275.00
280
290
300
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50
1.50%
-2.00%
3.00%
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
RAMSHEAD ROAD
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-409 GRADING AND DRAINAGE PLAN - IJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-409
GRADING AND
DRAINAGE
PLAN - I
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-410MATCHLINE - SHEETC-410GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES
WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR
SLOPES STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND
CONTINUOUS GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR
SHALL APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED
AREAS IN ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING
RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM
SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO
INVERT OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
WESNAD83NAD83LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
DPAXTON PLACEPISGAH COURTRAMSHEAD ROADRAMSHEAD ROAD 50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SFBUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF0+001+002+000+501+500+001+002+000+501+509+00 10+00 11+00 12+00 13+00
14+00
15+00
16+0
0 17+008+50 9+50 10+50 11+50 12+50 13+50
14+50
15+50 16+502
9
5 300305310
315
29
4
2
96
297 29829930130230330430
6
3
0
7
30
8
309
311
312
313
314
316
305
301
302
303
304
306
307
30
8
29
0
28
9
291292293 STM
G-81
STM
G-80
STM
G-70
STM
G-71
STM
G-61
STM
G-60
181.25' -
15" RCP
@ 4.00%
181.26' -
15" RCP
@ 1.50%
440.72' -
15" RCP
@ 3.00%
29.00' -
15" RCP
@ 5.00%
29.00' -
15" RCP
@ 1.50%
29.00' -
15" RCP
@ 5.36%
4.50%
1.50%
PVI STA = 9+68.40
PVI ELEV = 295.00
A.D. = 3.00%
K = 49.99
150.00' VC
BVCS: 8+93.40BVCE: 293.88EVCS: 10+43.40EVCE: 298.38PVI STA = 12+34.82
PVI ELEV = 306.99
A.D. = -3.00%
K = 33.33
100.00' VC
BVCS: 11+84.82BVCE: 304.74EVCS: 12+84.82EVCE: 307.74SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
RAMSHEAD ROAD
8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00
300
310
320 MATCHLINE
-
SHEETC-411DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-410 GRADING AND DRAINAGE PLAN - JJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-410
GRADING AND
DRAINAGE
PLAN - J
GDP-0
1"=40'
0 40102040MATCHLINE - SHEETC-411MATCHLINE - SHEETC-409MATCHLINE - SHEETC-409GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRAMSHEAD ROA
D
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE15+0
0
16+00
17+00
18+00
19+00
20+00
21+00
22+00
23+0023+07.43
15+50
16+50 17+50
18+50
19+50
20+50
21+50
22+50
3153
2
0
3
2
5
3
3
0
3
3
5
34
0
3
1
1
3
1
2
313314316317318
3
19
3
2
1
3
2
2
3
2
3
32
4 32632
7
32
8
3
2
9
3
3
1
3
3
2
3
3
3
3
3
4 336
3
37
3
3
8
3
3
9
34
1
342
STM
G-100
STM
G-110
STM
G-90
STM
G-81
STM
G-80
HP 342.49
29.00' -
15" RCP
@ 1.50%
181.45' -
15" RCP
@ 5.50%181.25' -
15" RCP
@ 4.00%
29.00' -
15" RCP
@ 5.00%WESNAD83NAD
83
320
330
340
350
5.00%
2.00%
PVI STA = 16+33.99
PVI ELEV = 312.98
A.D. = 3.50%
K = 50.00
175.00' VC
BVCS: 15+46.49BVCE: 311.66EVCS: 17+21.49EVCE: 317.35PVI STA = 21+57.18
PVI ELEV = 339.14
A.D. = -3.00%
K = 33.33
100.00' VC
BVCS: 21+07.18BVCE: 336.64EVCS: 22+07.18EVCE: 340.14SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
RAMSHEAD ROAD
15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-411 GRADING AND DRAINAGE PLAN - KJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-411
GRADING AND
DRAINAGE
PLAN - K
GDP-0MATCHLINE - SHEETC-4101"=40'
0 40102040MATCHLINE - SHEETC-410GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD
LOD
LO
D
LO
D
LOD
LOD
LOD
LOD
PISGAH COURT
RAMSHEAD ROAD60'
X
6
0
'
BUI
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 IN
0+00
1+00
2+00
2+69.16
0+50
1+50
2+50
12+0013+0014+0015+0012+5013+5014+50305310
304
306307308309311 3
0
0
305301302303304306307308300STM
G-70
STM
G-71
STM
H-30
STM
H-10
LP 299.79
HP 300.55
LP 299.91
51.14' -
15" RCP
@ 2.00%
135.41' -
15" RCP
@ 3.00%
29.00' -
15" RCP
@ 5.36%
STM
H-20 WESNAD83
NAD83DATUM ELEV
295.00
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
PISGAH COURT
300
310
320
300
310
320
0+00 0+50 1+00 1+50 2+00 2+50 3+00
-3.00%
-4.50
%
-2.00%
-2.00%
PVI STA = 1+90.16
PVI ELEV = 301.74
A.D. = 1.50%
K = 50.00
75.00' VC
BVCS: 1+52.66BVCE: 303.42EVCS: 2+27.66EVCE: 300.61DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-412 GRADING AND DRAINAGE PLAN - LJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-412
GRADING AND
DRAINAGE
PLAN - L
GDP-0
1"=40'
0 40102040
GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPAXTON PLACE
RAMSHEAD ROADWETLANDS
AREA
123,793 SF
OR
2.84 AC.50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60
'BUI
LD
INGENVE
LOPE3,600
SF
60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 IN
0+00 1+00 2+00 3+00 3+25.400+50 1+50 2+50
7+008+009+0010+007+508+509+5010+50295
300
291292293294296
297
298
299
290286287288289291292293STM
G-61STM
G-60 STM
I-30
STM
I-20
STM
I-10
TC 286.72
BC 286.22
LP 285.90
450.00' -
18" RCP
@ 1.50%
46.52' -
15" RCP
@ 2.50%
133.47' -
15" RCP
@ 3.50%
29.00' -
15" RCP
@ 1.50%WESNAD83
NAD83DATUM ELEV
285.00
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
PAXTON PLACE
290
300
290
300
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50
-3.00%
-2.00%
-2.00%DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-413 GRADING AND DRAINAGE PLAN - MJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-413
GRADING AND
DRAINAGE
PLAN - M
GDP-0
1"=40'
0 40102040
GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
S89°56'20"E 1569.80'N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 ACLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LODLOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRIDGEWOOD COURT
RAMSHEAD ROADWETLANDS
AREA
31,240 SF
OR
0.72 AC.60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60
'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFPROP. RIP RAP
OUTLET PROTECTION
MATERIAL = CLASS B
L = 7.5 FT
W1 = 3.8 FT
W2 = 12.4 FT
d50 = 8 IN
T = 12 IN
3+004+005+006+002+503+504+505+500+00 1+00 2+00 3+00 3+25.400+50 1+50 2+50
285290284286287288289 275280285276277278279281282283284286STM
G-50
STM
G-51
STM
J-30
STM
J-20
STM
J-10
LP 275.27
TC 276.14
BC 275.64
29.00' -
15" RCP
@ 1.50%
442.75' -
18" RCP
@ 2.50%
52.80' -
15" RCP
@ 2.00%
94.17' -
15" RCP
@ 3.00%WESNAD83
NAD83DATUM ELEV
270.00
SCALE: 1"= 40 ' HORIZONTAL
1"= 4 ' VERTICAL
RIDGEWOOD COURT
280
290
300
280
290
300
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50
-5.00
%
-3.00%
-2.00%
-2.00%
PVI STA = 2+46.40
PVI ELEV = 277.21
A.D. = 2.00%
K = 50.00
100.00' VC
BVCS: 1+96.40BVCE: 279.71EVCS: 2+96.40EVCE: 275.71DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-GDP-0----->LAYOUT: C-414 GRADING AND DRAINAGE PLAN - NJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-414
GRADING AND
DRAINAGE
PLAN - N
GDP-0
1"=40'
0 40102040
GRADING NOTES:
1.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN
ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS
TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD
LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH
CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. SLOPE MATTING IS TO BE USED FOR SLOPES
STEEPER THAN 3:1.
3.EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1'.
4.PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1' INTERVALS.
5.CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS
GRADE.
6.CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
7.TOPOGRAPHIC INFORMATION IS TAKEN FROM A BOUNDARY & TOPOGRAPHIC SURVEY BY BOHLER ENGINEERING. IF THE
CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE
CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE
OWNER FOR REVIEW.
8.ALL UN-SURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL
APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN
ACCORDANCE WITH GOVERNING SPECIFICATIONS UNTIL A HEALTHY STAND OF VEGETATION IS OBTAINED.
9.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODE AND BE CONSTRUCTED TO SAME.
DRAINAGE NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF ANY EXISTING STRUCTURES INCLUDING REMOVAL OF ANY EXISTING
UTILITIES.
2.PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION.
3.EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
4.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
5.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT.
6.ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING
& COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISHED GRADE. LIDS SHALL BE LABELED "STORM SEWER".
7.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE EPA OR APPLICABLE STATE GENERAL
N.P.D.E.S. PERMIT FOR STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND THE SPECIAL
CONDITIONS, SECTION 8, ENVIRONMENTAL COMPLIANCE AND STORM WATER POLLUTION PREVENTION.
8.ALL CONCRETE STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT. HDPE STRUCTURES MAY CONTAIN A SUMP AS ALLOWED BY THE MANUFACTURER
9.CONTRACTOR TO ADJUST ANY EXISTING STRUCTURES TO PROPOSED GRADE IN ANY AREA OF PROPOSED GRADING.
EXISTING NOTE
D
PROPOSED NOTE
OR
OR 516.4TC 516.4
OR
TC
BC
516.00
515.55
516.00TC
TYPICAL NOTE TEXT
GRADING & DRAINAGE LEGEND
SAN
#
120
STM
#
SAN
#
STM#
120 CONTOUR
LINE
SPOT
ELEVATIONS
SANITARY
LABEL
STORM
LABEL
STORM
SEWER
STORM
MANHOLE
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
125 125
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (A-10 TO A-60)
300
310
320
330
340
300
310
320
330
340
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00
STM
A-10
35.53' -
18" RCP
@ 4.00%
STM
A-20
259.48' -18" RCP @ 2.00%
STM
A-30
174.28'
-
15" RC
P
@ 4.50%
STM
A-40
67.39' -
15" RCP
@ 2.50%
STM
A-50
29.05' -
15" RCP
@ 1.50%
STM
A-60
PROP. FESRIM 308.27INV IN 306.83 (18") A-200+00PROP. CURB INLETRIM 313.61INV IN 308.46 (18") A-30INV IN 308.44 (15") A-20.1INV IN 308.48 (15") A-21INV OUT 308.25 (18") A-100+35.53PROP. CURB INLETRIM 317.66INV IN 313.74 (15") A-40INV IN 313.74 (15") A-31INV OUT 313.64 (18") A-202+95PROP. CURB INLETRIM 325.32INV IN 321.70 (15") A-50INV IN 321.71 (15") A-41INV OUT 321.60 (15") A-304+69.28PROP. CURB INLETRIM 327.46INV IN 323.48 (15") A-60INV OUT 323.38 (15") A-405+36.67PROP. CURB INLETRIM 327.42INV OUT 323.92 (15") A-505+65.71PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (A-20 TO A-20.1)
300
310
320
300
310
320
0+00 0+50
STM
A-20
37.00' -
15" RCP
@ 4.50%
STM
A-20.1
PROP. CURB INLETRIM 313.61INV IN 308.46 (18") A-30INV IN 308.44 (15") A-20.1INV IN 308.48 (15") A-21INV OUT 308.25 (18") A-100+00PROP. CURB INLETRIM 313.61INV OUT 310.11 (15") A-200+37PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (A-20 TO A-23)
300
310
320
330
300
310
320
330
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00
141.97' -15" RCP @ 2.00%
STM
A-21
187.77' -
15" RCP
@ 3.50%
STM
A-22
37.00' -
15" RCP
@ 1.50%
STM
A-23
STM
A-20
PROP. CURB INLETRIM 315.77INV IN 311.60 (15") A-22INV IN 311.72 (15") A-21.1INV OUT 311.32 (15") A-201+41.97PROP. CURB INLETRIM 323.34INV IN 318.27 (15") A-23INV OUT 318.17 (15") A-213+29.74PROP. CURB INLETRIM 323.32INV OUT 318.82 (15") A-223+66.74PROP. CURB INLETRIM 313.61INV IN 308.46 (18") A-30INV IN 308.44 (15") A-20.1INV IN 308.48 (15") A-21INV OUT 308.25 (18") A-100+00PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (A-30 TO A-31)
300
310
320
300
310
320
0+00 0+50
STM
A-30
37.28' -
15" RCP
@ 1.50%
STM
A-31
PROP. CURB INLETRIM 317.66INV IN 313.74 (15") A-40INV IN 313.74 (15") A-31INV OUT 313.64 (18") A-200+00PROP. CURB INLETRIM 317.80INV OUT 314.30 (15") A-300+37.28PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (C-10 TO C-30)
300
310
320
300
310
320
0+00 0+50 1+00
STM
C-10
33.34' -
15" RCP
@ 1.00%
STM
C-20
37.00' -
15" RCP
@ 8.50%
STM
C-30
PROP. FESRIM 312.61INV IN 311.17 (15") C-200+00PROP. CURB INLETRIM 318.25INV IN 311.60 (15") C-30INV OUT 311.50 (15") C-100+33.34PROP. CURB INLETRIM 318.25INV OUT 314.75 (15") C-200+70.34PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (A-40 TO A-41)
310
320
330
310
320
330
0+00 0+50 1+00
57.47' -
15" RCP
@ 4.00%
STM
A-41
STM
A-40
PROP. CURB INLETRIM 327.51INV OUT 324.01 (15") A-400+57.47PROP. CURB INLETRIM 325.32INV IN 321.70 (15") A-50INV IN 321.71 (15") A-41INV OUT 321.60 (15") A-300+00PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (A-21 TO A-21.1)
300
310
320
300
310
320
0+00 0+50
STM
A-21
37.00' -
15" RCP
@ 1.50%
STM
A-21.1
PROP. CURB INLETRIM 315.77INV IN 311.60 (15") A-22INV IN 311.72 (15") A-21.1INV OUT 311.32 (15") A-200+00PROP. CURB INLETRIM 315.77INV OUT 312.27 (15") A-210+37PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-415 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-415
STORM SEWER
PROFILES
PPD-0
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (D-10 TO D-80)
260
270
280
290
300
310
320
330
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00
400.00' -
1
5
"
R
C
P
@
3
.
5
0
%
STM
D-40
284.74' - 1
5
"
R
C
P
@
3
.
0
0
%
STM
D-50
164.09' -
1
8
"
R
C
P
@
3
.
5
0
%
STM
D-30
STM
D-10
129.90'
-
2
4
"
R
C
P
@
5.
0
0
%
STM
D-20
PROP. CURB INLETRIM 278.46INV IN 274.38 (18") D-31INV IN 274.57 (15") D-40INV OUT 274.07 (18") D-202+93.98PROP. FESRIM 263.28INV IN 261.03 (24") D-200+00PROP. CURB INLETRIM 274.29INV IN 268.40 (15") D-21INV IN 268.33 (18") D-30INV OUT 267.52 (24") D-101+29.90PROP. CURB INLETRIM 293.70INV IN 288.95 (15") D-50INV IN 288.89 (15") D-41INV OUT 288.57 (15") D-306+93.98PROP. CURB INLETRIM 302.14INV IN 297.79 (15") D-60INV IN 298.20 (15") D-51INV OUT 297.49 (15") D-409+78.72PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-416 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AMATCHLINE - SHEETC-417PPD-0
C-416
STORM SEWER
PROFILES
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (D-10 TO D-80)
260
270
280
290
300
310
320
330
6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50
STM
D-40
284.74' - 1
5
"
R
C
P
@
3
.
0
0
%
STM
D-50 299.09'
-
1
5
"
R
C
P
@
4.
0
0
%
STM
D-60
299.09' - 15"
R
C
P
@
2
.
0
0
%
STM
D-70
29.00' - 15" RCP @ 1.50%
STM
D-80
PROP. CURB INLETRIM 293.70INV IN 288.95 (15") D-50INV IN 288.89 (15") D-41INV OUT 288.57 (15") D-306+93.98PROP. CURB INLETRIM 302.14INV IN 297.79 (15") D-60INV IN 298.20 (15") D-51INV OUT 297.49 (15") D-409+78.72PROP. CURB INLETRIM 314.72INV IN 310.05 (15") D-70INV IN 310.78 (15") D-61INV OUT 309.75 (15") D-5012+77.80PROP. CURB INLETRIM 320.07INV IN 316.14 (15") D-80INV OUT 316.04 (15") D-6015+76.89PROP. CURB INLETRIM 320.07INV OUT 316.57 (15") D-7016+05.89PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-417 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AMATCHLINE - SHEETC-416PPD-0
C-417
STORM SEWER
PROFILES
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (D-40 TO D-41)
280
290
300
280
290
300
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (D-50 TO D-51)
290
300
310
290
300
310
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (D-60 TO D-61)
300
310
320
300
310
320
0+00 0+50 0+00 0+50 0+00 0+50
STM
D-60
29.00' -
15" RCP
@ 1.50%
STM
D-61
STM
D-50
29.00' -
15" RCP
@ 1.50%
STM
D-51
STM
D-40
29.00' -
15" RCP
@ 4.50%
STM
D-41
PROP. CURB INLETRIM 314.72INV IN 310.05 (15") D-70INV IN 310.78 (15") D-61INV OUT 309.75 (15") D-500+00PROP. CURB INLETRIM 314.72INV OUT 311.22 (15") D-600+29PROP. CURB INLETRIM 302.14INV IN 297.79 (15") D-60INV IN 298.20 (15") D-51INV OUT 297.49 (15") D-400+00PROP. CURB INLETRIM 302.14INV OUT 298.64 (15") D-500+29PROP. CURB INLETRIM 293.70INV IN 288.95 (15") D-50INV IN 288.89 (15") D-41INV OUT 288.57 (15") D-300+00PROP. CURB INLETRIM 293.70INV OUT 290.20 (15") D-400+29PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (D-30 TO D-31)
270
280
290
270
280
290
0+00 0+50
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (D-20 TO D-21)
260
270
280
260
270
280
0+00 0+50 1+00
STM
D-30
29.00' -
18" RCP
@ 2.00%
STM
D-31
STM
D-20
54.32' -
15" RCP
@ 5.00%
STM
D-21
PROP. CURB INLETRIM 278.46INV IN 274.38 (18") D-31INV IN 274.57 (15") D-40INV OUT 274.07 (18") D-200+00PROP. CURB INLETRIM 278.46INV OUT 274.96 (18") D-300+29PROP. CURB INLETRIM 274.29INV IN 268.40 (15") D-21INV IN 268.33 (18") D-30INV OUT 267.52 (24") D-100+00PROP. CURB INLETRIM 274.61INV OUT 271.11 (15") D-200+54.32PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-418 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
APPD-0
C-418
STORM SEWER
PROFILES
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (E-50 TO E-51)
300
310
320
300
310
320
0+00 0+50
STM
E-51
29.00' - 15" RCP @ 1.50%
STM
E-50
PROP. CURB INLETRIM 309.34INV OUT 305.84 (15") E-500+29PROP. CURB INLETRIM 309.34INV IN 304.78 (15") E-60INV IN 305.40 (15") E-51INV OUT 304.68 (15") E-400+00PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (E-10 TO E-80)
280
290
300
310
320
330
340
280
290
300
310
320
330
340
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50
STM
E-10
STM
E-50
STM
E-40
245.13' -
1
5
"
R
C
P
@
5.
0
0
%
207.51' - 18
"
R
C
P
@
2
.
5
0
%
165.04' -
1
5"
R
C
P
@
5.
5
0
%
177.31' - 1
5
"
R
C
P
@
3
.
0
0
%
257.01' - 15" R
C
P
@
2
.
0
0
%
STM
E-60
STM
E-70
29.00' - 15" RCP @ 1.50%
STM
E-80
STM
E-20
STM
E-30
29.00' - 15" RCP @ 4.00%PROP. CURB INLETRIM 297.65INV IN 294.12 (15") E-40INV OUT 294.02 (15") E-202+36.51PROP. CURB INLETRIM 317.84INV IN 313.96 (15") E-70INV OUT 313.86 (15") E-508+35.88PROP. CURB INLETRIM 330.28INV IN 326.32 (15") E-80INV OUT 326.22 (15") E-6010+81PROP. CURB INLETRIM 330.28INV OUT 326.75 (15") E-7011+10PROP. CURB INLETRIM 297.65INV IN 292.86 (15") E-30INV OUT 292.39 (18") E-102+07.51PROP. FESRIM 288.91INV IN 287.20 (18") E-200+00PROP. CURB INLETRIM 309.34INV IN 304.78 (15") E-60INV IN 305.40 (15") E-51INV OUT 304.68 (15") E-406+70.83PROP. CURB INLETRIM 303.61INV IN 299.36 (15") E-50INV OUT 299.26 (15") E-304+93.52PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-419 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
APPD-0
C-419
STORM SEWER
PROFILES
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-10 TO G-110)
260
270
280
290
300
310
320
330
340
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00
450.00' -18" RCP @ 1.50%
STM
G-60
STM
G-50
442.75' - 18"
R
C
P
@
2
.
5
0
%
STM
G-40
56.56' - 24" RCP @ 1.50%
STM
G-30
197.42' - 24" R
C
P
@
2
.
0
0
%
18.95' - 24" RCP @ 3.96%
STM
G-10
PROP. CURB INLETRIM 277.05INV IN 271.75 (24") G-40INV OUT 271.58 (24") G-202+16.37PROP. CURB INLETRIM 294.81INV IN 290.89 (15") G-70INV IN 290.82 (15") G-61INV OUT 290.72 (18") G-5011+65.67PROP. FESRIM 267.00INV IN 264.75 (24") G-200+00PROP. CURB INLETRIM 278.14INV IN 272.70 (18") G-50INV IN 272.94 (15") G-41INV OUT 272.60 (24") G-302+72.92PROP. CURB INLETRIM 287.88INV IN 283.86 (15") G-51INV IN 283.97 (18") G-60INV OUT 283.76 (18") G-407+15.67PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-420 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AMATCHLINE - SHEETC-421PPD-0
C-420
STORM SEWER
PROFILES
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-10 TO G-110)
260
270
280
290
300
310
320
330
340
9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00
450.00' -18" RCP @ 1.50%
440.72' -15" RCP
@ 3.00%
STM
G-70
181.26' -15" RCP @ 1.50%
STM
G-80
181.25'
-
15" RCP
@ 4.00%
STM
G-90
181.45' -
15" RC
P
@ 5.50
%
STM
G-100
29.00' -
15" RCP
@ 1.50%
STM
G-110
STM
G-60
PROP. CURB INLETRIM 294.81INV IN 290.89 (15") G-70INV IN 290.82 (15") G-61INV OUT 290.72 (18") G-5011+65.67PROP. CURB INLETRIM 309.27INV IN 304.22 (15") G-80INV IN 304.22 (15") G-71INV OUT 304.12 (15") G-6016+06.39PROP. CURB INLETRIM 312.13INV IN 307.03 (15") G-90INV IN 307.18 (15") G-81INV OUT 306.94 (15") G-7017+87.65PROP. CURB INLETRIM 319.14INV IN 314.39 (15") G-100INV OUT 314.28 (15") G-8019+68.90PROP. CURB INLETRIM 328.46INV IN 324.46 (15") G-110INV OUT 324.36 (15") G-9021+50.35PROP. CURB INLETRIM 328.46INV OUT 324.90 (15") G-10021+79.35PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-421 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AMATCHLINE - SHEETC-420PPD-0
C-421
STORM SEWER
PROFILES
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-20 TO G-24)
260
270
280
290
260
270
280
290
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-20 TO G-20.1)
260
270
280
260
270
280STM
G-21
STM
G-22
158.38' -15" RCP @ 2.50%
STM
G-23
STM
G-24
0+00 0+50
STM
G-20.1
152.85' - 15
"
R
C
P
@
2
.
5
0
%PROP. CURB INLETRIM 276.10INV IN 270.86 (15") G-21.1INV IN 271.69 (15") G-22INV OUT 270.76 (18") G-201+71.86PROP. CURB INLETRIM 279.79INV IN 275.61 (15") G-23INV OUT 275.51 (15") G-213+24.71PROP. CURB INLETRIM 283.60INV IN 279.67 (15") G-24INV OUT 279.57 (15") G-224+83.09PROP. CURB INLETRIM 273.38INV OUT 269.46 (15") G-200+29PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
29.00' - 15" RCP @ 1.50%
STM
G-24
PROP. CURB INLETRIM 283.60INV OUT 280.10 (15") G-235+12.09171.86' - 18" RCP @
1
.
5
0
%PROP. CURB INLETRIM 273.38INV IN 268.30 (15") G-20.1INV IN 268.18 (18") G-21INV IN 267.64 (24") G-30INV OUT 265.50 (24") G-100+0029.00' -
15" RCP
@ 4.00%
STM
G-20
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-50 TO G-51)
270
280
290
270
280
290
0+00 0+50
1"= 5 ' VERTICAL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-40 TO G-41)
270
280
290
270
280
290
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-60 TO G-61)
280
290
300
280
290
300
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-70 TO G-71)
300
310
320
300
310
320
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (G-80 TO G-81)
300
310
320
300
310
320
0+00 0+50 0+00 0+50
STM
G-50
STM
G-51
29.00' -
15" RCP
@ 1.50%
STM
G-61
STM
G-80
29.00' -
15" RCP
@ 5.00%
STM
G-81
STM
G-60
0+00 0+50 0+00 0+50
STM
G-41
29.71' - 15" RCP @ 5.50%
STM
G-40
STM
G-71
STM
G-70
29.00' - 15" RCP @ 5.36%
29.00' - 15" RCP @ 1.50%PROP. CURB INLETRIM 287.88INV IN 283.86 (15") G-51INV IN 283.97 (18") G-60INV OUT 283.76 (18") G-400+00PROP. CURB INLETRIM 287.88INV OUT 284.30 (15") G-500+29PROP. CURB INLETRIM 294.81INV IN 290.89 (15") G-70INV IN 290.82 (15") G-61INV OUT 290.72 (18") G-500+00PROP. CURB INLETRIM 294.81INV OUT 291.25 (15") G-600+29PROP. CURB INLETRIM 312.13INV IN 307.03 (15") G-90INV IN 307.18 (15") G-81INV OUT 306.94 (15") G-700+00PROP. CURB INLETRIM 312.13INV OUT 308.63 (15") G-800+29PROP. CURB INLETRIM 309.27INV OUT 305.77 (15") G-700+29PROP. CURB INLETRIM 309.27INV IN 304.22 (15") G-80INV IN 304.22 (15") G-71INV OUT 304.12 (15") G-600+00PROP. CURB INLETRIM 278.08INV OUT 274.58 (15") G-400+29.71PROP. CURB INLETRIM 278.14INV IN 272.70 (18") G-50INV IN 272.94 (15") G-41INV OUT 272.60 (24") G-300+00PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
PROP. CURB INLETRIM 294.81INV IN 290.89 (15") G-70INV IN 290.82 (15") G-61INV OUT 290.72 (18") G-500+00PROP. CURB INLETRIM 294.81INV IN 290.89 (15") G-70INV IN 290.82 (15") G-61INV OUT 290.72 (18") G-500+00SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE ( G-21 TO G-21.1)
260
270
280
260
270
280
0+00 0+50
PROP. GRADE
STM
G-21.1
STM
G-21
10 YR HGL
PROP. CURB INLETRIM 276.10INV IN 270.86 (15") G-21.1INV IN 271.69 (15") G-22INV OUT 270.76 (18") G-200+00PROP. CURB INLETRIM 276.10INV OUT 271.30 (15") G-210+2929.00' -
15" RCP
@ 1.50%DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-422 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
APPD-0
C-422
STORM SEWER
PROFILES
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (H-10 TO H-30)
290
300
310
290
300
310
0+00 0+50 1+00 1+50 2+00
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (I-10 TO I-30)
270
280
290
270
280
290
0+00 0+50 1+00 1+50 2+00
STM
H-10
135.41' -15" RCP
@ 3.00%
STM
H-20
51.14' -
15" RCP
@ 2.00%
STM
H-30
STM
I-30
46.52' -
15" RCP
@ 2.50%
STM
I-20
133.47' -
15" RCP
@ 3.50%
STM
I-10
PROP. FESRIM 292.06INV IN 290.62 (15") H-200+00PROP. CURB INLETRIM 299.79INV IN 294.98 (15") H-30INV OUT 294.69 (15") H-101+35.41PROP. CURB INLETRIM 299.54INV OUT 296.00 (15") H-201+86.55PROP. CURB INLETRIM 286.22INV OUT 282.50 (15") I-201+79.99PROP. CURB INLETRIM 285.90INV IN 281.34 (15") I-30INV OUT 281.07 (15") I-101+33.47PROP. FESRIM 277.83INV IN 276.40 (15") I-200+00PROP. GRADE
10 YR HGL
PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (J-10 TO J-30)
260
270
280
260
270
280
0+00 0+50 1+00 1+50
STM
J-10
94.17' -15" RCP
@ 3.00%
STM
J-20
52.80' -
15" RCP
@ 2.00%
STM
J-30
PROP. CURB INLETRIM 275.27INV IN 271.04 (15") J-30INV OUT 270.78 (15") J-100+94.17PROP. CURB INLETRIM 275.64INV OUT 272.10 (15") J-201+46.98PROP. FESRIM 269.39INV IN 267.95 (15") J-200+00PROP. GRADE
10 YR HGL
SCALE: 1"= 50 ' HORIZONTAL
1"= 5 ' VERTICAL
PROPOSED STORM SEWER PROFILE (K-10 TO K-30)
260
270
280
260
270
280
0+00 0+50 1+00 1+50 2+00
STM
K-10
100.2
7' -
15" RC
P
@ 5.50
%
STM
K-20
53.68' -
15" RCP
@ 2.00%
STM
K-30
PROP. FESRIM 266.87INV IN 265.43 (15") K-200+00PROP. CURB INLETRIM 275.61INV IN 271.13 (15") K-30INV OUT 270.94 (15") K-101+00.27PROP. CURB INLETRIM 275.74INV OUT 272.20 (15") K-201+53.95PROP. GRADE
10 YR HGL
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-423 STORM SEWER PROFILESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
APPD-0
C-423
STORM SEWER
PROFILES
STORM STRUCTURE SCHEDULE
NAME
A-10
A-20
A-20.1
A-21
A-21.1
A-22
A-23
A-30
A-31
A-40
A-41
A-50
A-60
C-10
C-20
C-30
D-10
D-20
D-21
D-30
D-31
D-40
D-41
D-50
D-51
D-60
D-61
D-70
D-80
TYPE
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
RIM ELEV.
(FT.)
308.27'
313.61'
313.61'
315.77'
315.77'
323.34'
323.32'
317.66'
317.80'
325.32'
327.51'
327.46'
327.42'
312.61'
318.25'
318.25'
263.28'
274.29'
274.61'
278.46'
278.46'
293.70'
293.70'
302.14'
302.14'
314.72'
314.72'
320.07'
320.07'
INVERTS
INV IN = 306.83' (18")
INV IN = 308.46' (18")
INV IN = 308.44' (15")
INV IN = 308.48' (15")
INV OUT = 308.25' (18")
INV OUT = 310.11' (15")
INV IN = 311.60' (15")
INV IN = 311.72' (15")
INV OUT = 311.32' (15")
INV OUT = 312.27' (15")
INV IN = 318.27' (15")
INV OUT = 318.17' (15")
INV OUT = 318.82' (15")
INV IN = 313.74' (15")
INV IN = 313.74' (15")
INV OUT = 313.64' (18")
INV OUT = 314.30' (15")
INV IN = 321.70' (15")
INV IN = 321.71' (15")
INV OUT = 321.60' (15")
INV OUT = 324.01' (15")
INV IN = 323.48' (15")
INV OUT = 323.38' (15")
INV OUT = 323.92' (15")
INV IN = 311.17' (15")
INV IN = 311.60' (15")
INV OUT = 311.50' (15")
INV OUT = 314.75' (15")
INV IN = 261.03' (24")
INV IN = 268.40' (15")
INV IN = 268.33' (18")
INV OUT = 267.52' (24")
INV OUT = 271.11' (15")
INV IN = 274.38' (18")
INV IN = 274.57' (15")
INV OUT = 274.07' (18")
INV OUT = 274.96' (18")
INV IN = 288.95' (15")
INV IN = 288.89' (15")
INV OUT = 288.57' (15")
INV OUT = 290.20' (15")
INV IN = 297.79' (15")
INV IN = 298.20' (15")
INV OUT = 297.49' (15")
INV OUT = 298.64' (15")
INV IN = 310.05' (15")
INV IN = 310.78' (15")
INV OUT = 309.75' (15")
INV OUT = 311.22' (15")
INV IN = 316.14' (15")
INV OUT = 316.04' (15")
INV OUT = 316.57' (15")
STORM SEWER PIPE SCHEDULE
FROM
A-10
A-20
A-20
A-20.1
A-21
A-21.1
A-22
A-30
A-31
A-40
A-41
A-50
C-10
C-20
D-10
D-20
D-20
D-30
D-30
D-40
D-41
D-50
D-51
D-60
D-61
D-70
FROM
INV
306.83'
308.48'
308.46'
310.11'
311.60'
312.27'
318.27'
313.74'
314.30'
321.70'
324.01'
323.48'
311.17'
311.60'
261.03'
268.40'
268.33'
274.38'
274.57'
288.95'
290.20'
297.79'
298.64'
310.05'
311.22'
316.14'
TO
A-20
A-21
A-30
A-20
A-22
A-21
A-23
A-40
A-30
A-50
A-40
A-60
C-20
C-30
D-20
D-21
D-30
D-31
D-40
D-50
D-40
D-60
D-50
D-70
D-60
D-80
TO
INV
308.25'
311.32'
313.64'
308.44'
318.17'
311.72'
318.82'
321.60'
313.74'
323.38'
321.71'
323.92'
311.50'
314.75'
267.52'
271.11'
274.07'
274.96'
288.57'
297.49'
288.89'
309.75'
298.20'
316.04'
310.78'
316.57'
PIPE
LENGTH
35.53'
141.97'
259.48'
37.00'
187.77'
37.00'
37.00'
174.28'
37.28'
67.39'
57.47'
29.05'
33.34'
37.00'
129.90'
54.32'
164.09'
29.00'
400.00'
284.74'
29.00'
299.09'
29.00'
299.09'
29.00'
29.00'
SLOPE
(%)
4.00%
2.00%
2.00%
4.50%
3.50%
1.50%
1.50%
4.50%
1.50%
2.50%
4.00%
1.50%
1.00%
8.50%
5.00%
5.00%
3.50%
2.00%
3.50%
3.00%
4.50%
4.00%
1.50%
2.00%
1.50%
1.50%
DIAMETER
(IN.)
18"
15"
18"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
24"
15"
18"
18"
15"
15"
15"
15"
15"
15"
15"
15"
MATERIAL
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
STORM SEWER PIPE SCHEDULE
FROM
E-10
E-20
E-30
E-40
E-50
E-50
E-60
E-70
G-10
G-20
G-20
G-20
G-21
G-21
G-22
G-23
G-30
G-40
G-41
G-50
G-50
G-60
G-61
G-70
G-70
G-80
G-81
G-90
G-100
H-10
H-20
I-10
I-20
J-10
J-20
K-10
K-20
FROM
INV
287.20'
292.86'
294.12'
299.36'
305.40'
304.78'
313.96'
326.32'
264.75'
268.18'
268.30'
267.64'
270.86'
271.69'
275.61'
279.67'
271.75'
272.70'
274.58'
283.86'
283.97'
290.89'
291.25'
304.22'
304.22'
307.03'
308.63'
314.39'
324.46'
290.62'
294.98'
276.40'
281.34'
267.95'
271.04'
265.43'
271.13'
TO
E-20
E-30
E-40
E-50
E-51
E-60
E-70
E-80
G-20
G-21
G-20.1
G-30
G-21.1
G-22
G-23
G-24
G-40
G-50
G-40
G-51
G-60
G-70
G-60
G-71
G-80
G-90
G-80
G-100
G-110
H-20
H-30
I-20
I-30
J-20
J-30
K-20
K-30
TO
INV
292.39'
294.02'
299.26'
304.68'
305.84'
313.86'
326.22'
326.75'
265.50'
270.76'
269.46'
271.58'
271.30'
275.51'
279.57'
280.10'
272.60'
283.76'
272.94'
284.30'
290.72'
304.12'
290.82'
305.77'
306.94'
314.28'
307.18'
324.36'
324.90'
294.69'
296.00'
281.07'
282.50'
270.78'
272.10'
270.94'
272.20'
PIPE
LENGTH
207.51'
29.00'
257.01'
177.31'
29.00'
165.04'
245.13'
29.00'
18.95'
171.86'
29.00'
197.42'
29.00'
152.85'
158.38'
29.00'
56.56'
442.75'
29.71'
29.00'
450.00'
440.72'
29.00'
29.00'
181.26'
181.25'
29.00'
181.45'
29.00'
135.41'
51.14'
133.47'
46.52'
94.17'
52.80'
100.27'
53.68'
SLOPE
(%)
2.50%
4.00%
2.00%
3.00%
1.50%
5.50%
5.00%
1.50%
3.96%
1.50%
4.00%
2.00%
1.50%
2.50%
2.50%
1.50%
1.50%
2.50%
5.50%
1.50%
1.50%
3.00%
1.50%
5.36%
1.50%
4.00%
5.00%
5.50%
1.50%
3.00%
2.00%
3.50%
2.50%
3.00%
2.00%
5.50%
2.00%
DIAMETER
(IN.)
18"
15"
15"
15"
15"
15"
15"
15"
24"
18"
15"
24"
15"
15"
15"
15"
24"
18"
15"
15"
18"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
15"
MATERIAL
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
RCP
STORM STRUCTURE SCHEDULE
NAME
E-10
E-20
E-30
E-40
E-50
E-51
E-60
E-70
E-80
G-10
G-20
G-20.1
G-21
G-21.1
G-22
G-23
G-24
G-30
G-40
G-41
G-50
G-51
G-60
G-61
G-70
G-71
G-80
G-81
G-90
G-100
G-110
H-10
H-20
H-30
I-10
I-20
I-30
J-10
J-20
J-30
K-10
K-20
K-30
TYPE
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. CURB INLET
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
PROP. FES
PROP. CURB INLET
PROP. CURB INLET
RIM ELEV.
(FT.)
288.91'
297.65'
297.65'
303.61'
309.34'
309.34'
317.84'
330.28'
330.28'
267.00'
273.38'
273.38'
276.10'
276.10'
279.79'
283.60'
283.60'
277.05'
278.14'
278.08'
287.88'
287.88'
294.81'
294.81'
309.27'
309.27'
312.13'
312.13'
319.14'
328.46'
328.46'
292.06'
299.79'
299.54'
277.83'
285.90'
286.22'
269.39'
275.27'
275.64'
266.87'
275.61'
275.74'
INVERTS
INV IN = 287.20' (18")
INV IN = 292.86' (15")
INV OUT = 292.39' (18")
INV IN = 294.12' (15")
INV OUT = 294.02' (15")
INV IN = 299.36' (15")
INV OUT = 299.26' (15")
INV IN = 304.78' (15")
INV IN = 305.40' (15")
INV OUT = 304.68' (15")
INV OUT = 305.84' (15")
INV IN = 313.96' (15")
INV OUT = 313.86' (15")
INV IN = 326.32' (15")
INV OUT = 326.22' (15")
INV OUT = 326.75' (15")
INV IN = 264.75' (24")
INV IN = 268.30' (15")
INV IN = 268.18' (18")
INV IN = 267.64' (24")
INV OUT = 265.50' (24")
INV OUT = 269.46' (15")
INV IN = 270.86' (15")
INV IN = 271.69' (15")
INV OUT = 270.76' (18")
INV OUT = 271.30' (15")
INV IN = 275.61' (15")
INV OUT = 275.51' (15")
INV IN = 279.67' (15")
INV OUT = 279.57' (15")
INV OUT = 280.10' (15")
INV IN = 271.75' (24")
INV OUT = 271.58' (24")
INV IN = 272.70' (18")
INV IN = 272.94' (15")
INV OUT = 272.60' (24")
INV OUT = 274.58' (15")
INV IN = 283.86' (15")
INV IN = 283.97' (18")
INV OUT = 283.76' (18")
INV OUT = 284.30' (15")
INV IN = 290.89' (15")
INV IN = 290.82' (15")
INV OUT = 290.72' (18")
INV OUT = 291.25' (15")
INV IN = 304.22' (15")
INV IN = 304.22' (15")
INV OUT = 304.12' (15")
INV OUT = 305.77' (15")
INV IN = 307.03' (15")
INV IN = 307.18' (15")
INV OUT = 306.94' (15")
INV OUT = 308.63' (15")
INV IN = 314.39' (15")
INV OUT = 314.28' (15")
INV IN = 324.46' (15")
INV OUT = 324.36' (15")
INV OUT = 324.90' (15")
INV IN = 290.62' (15")
INV IN = 294.98' (15")
INV OUT = 294.69' (15")
INV OUT = 296.00' (15")
INV IN = 276.40' (15")
INV IN = 281.34' (15")
INV OUT = 281.07' (15")
INV OUT = 282.50' (15")
INV IN = 267.95' (15")
INV IN = 271.04' (15")
INV OUT = 270.78' (15")
INV OUT = 272.10' (15")
INV IN = 265.43' (15")
INV IN = 271.13' (15")
INV OUT = 270.94' (15")
INV OUT = 272.20' (15")DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-PPD-0----->LAYOUT: C-424 STORM SEWER SCHEDULESJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
APPD-0
C-424
STORM SEWER
SCHEDULES
LOD
LOD
LODLOD LOD LOD LODLODLODLODLOD
LODLODLOD LOD LODLODLOD LODLOD
LODLODLOD LOD LOD LODLOD LODL
O
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD
LOD
LOD
LOD LOD LODLODLODLOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD
LOD
LOD LODLODLODLODLODLODLODLODLO
D
LOD
LOD LOD
LOD LOD LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LODLODLODLODLODLO
D
LODLODLODLODLODLOD50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X5
0
'BUILD
I
N
G
ENV
E
L
O
P
E
2,50
0
S
F
50'X50'
BUILDING
ENVELOPE
2,500 SF 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE
2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUIL
DI
NG
ENVELOPE
2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDIN
G
ENVELOP
E
2,500 SF
50'X50
'
BUILDI
N
G
ENVEL
O
P
E
2,500
S
F
50'X50'BUILDINGENVELOPE2,500 SF
50'X50'BUILDINGENVELOPE
2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X6
0
'BUIL
D
I
N
G
ENVE
L
O
P
E
3,600
S
F
60'
X
6
0
'
BU
I
L
D
I
N
G
E
N
V
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOP
E
3,600 SF
60'X60'BUILDI
N
G
ENVELOP
E3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
50'X50'BUILDINGENVELOPE
2,500 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'
X
6
0
'
BUI
L
D
I
N
G
ENV
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
6
0
'
X
6
0
'
BU
I
L
D
I
N
G
E
N
V
E
LO
P
E
3,
6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDI
N
G
ENVELO
P
E
3,600 S
F
60
'
X
6
0
'
BU
I
L
D
I
N
G
E
N
V
E
LO
P
E
3,
6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60
'BUILD
I
N
G
ENVEL
O
P
E
3,600
S
F 60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDI
NG
ENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDI
N
G
ENVELO
P
E
3,600 S
F
50'X50'
BUILDING
ENVELOPE
2,500 SF
60'X6
0'
BUILDIN
G
ENVE
L
OPE
3,600 SF 60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE3,600 SF
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDING
ENVELOPE3,600 SF
60'X6
0'
BUILDI
N
G
ENVEL
OPE
3,600
S
F
60'X60'BUILDING
ENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'BUILDINGENVELOPE3,600 SF
60'X60'
BUILDING
ENVELO
P
E
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF60'X60'
BUILDIN
G
ENVELOP
E
3,600 SF
60'X60'
BUILDIN
G
ENVEL
O
P
E
3,600
S
F
60'X60'BUILDING
ENVELOPE3,600 SF
60'X
6
0'BUILDIN
G
ENVELOPE3,600 SF
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'BUILDINGENVELOPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
SF 60'X60'BUILDING
ENVEL
OPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X50'
BUILDING
ENVELOPE
2,500 SF
60'X60'BUILDIN
GENVELO
P
E
3,600 S
F
60'X60'BUILDINGENVELOPE3,600 SF
F
F F
F
F
F
F
F
FFFFFFFFFFFFFF
FFFFFFF
F
F F
F F
F FFFFFFFFFFFFFFFF F F F F F F F
A B
G
CDEFHIKNMLW E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-500 OVERALL UTILITY PLANJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-500
OVERALL
UTILITY PLAN
UTP-0
1"=200'
0 20050100200
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD
LOD
LOD LODLODLOD
LOD
LOD
LOD LODLOD
LODKINGWOOD COURTEXECU
T
I
V
E
D
R
I
V
E
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
BUILDING
ENVELOP
E
F
F
F
F
F
F
F
F
F
F
F F F F F F
F
F
F
F
F
F
FAPPROX. LOCATION OF PROP.
CONN. TO EX. FIRE WATER LINE
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)
PROP. TEE
FITTING (TYP.)
PROP. GATE
VALVE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
W E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-501 UTILITY PLAN - AJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-501
UTILITY PLAN -
A
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-502PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
LODLOD
LOD
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD LOD
LOD
LOD
LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTACKETT COURTEXECU
T
I
V
E
D
R
I
V
ETRAVELERS WAY50'X50'
BUILDING
ENVELOP
E
2,500 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 SF
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDIN
G
ENVELO
P
E
3,600 S
F
50'X50
'
BUILDI
N
G
ENVEL
O
P
E
2,500
S
F
PROP 35
'
F
R
O
N
T
S
E
T
B
A
C
K PROP 25'' REAR SETBACK7+00
8+00 9+00
10+00
11+00
12+00
13+00
13+86.0
1
6+50
7+50
8+50
9+50
10+50
11+50
12+50
13+50
1+002+003+001+502+503+50F
F
F
F
F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FFFFFFF
FFFFFWPROP. Y CONNECTOR
FOR DOMESTIC
SERVICE LINES (TYP.)
PROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 1" DOMESTIC WATER
METER ASSEMBLIES (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. 8"X8" CROSS
FITTING (TYP.)
W E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-502 UTILITY PLAN - BJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-502
UTILITY PLAN -
B
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-501PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
S69°59'18"W
717
.95
'LODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LODLODLODLODLODTACK
E
T
T
C
O
U
R
T
EXECUTIVE DRIVETRAVE
L
E
R
S
W
A
Y50'X50
'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SFPROP 35'
F
R
O
N
T
S
E
T
B
A
C
K8+009+0010+0011+008+509+5010+500+00
1+00
2+00
3+00
4+00
5+00
6+00
0+50
1+50
2+50
3+50
4+50
5+50FFFFFFFF
FFFF
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FFFFFF
WWWPROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-503 UTILITY PLAN - CJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-503
UTILITY PLAN -
C
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-504PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD
LOD LOD LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY 50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF6+00
7+00
8+00
9+00
10+00
11+00
12+00
13+00
14+00 15+00
6+50
7+50
8+50
9+50
10+50
11+50
12+50
13+50 14+50
FFF
F
F
F
F
F
F
F
F
F F F
F F F F F F F F F F F F F F F F F FWWWWWPROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-504 UTILITY PLAN - DJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-504
UTILITY PLAN -
D
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-505MATCHLINE - SHEETC-503PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
N73°23'50"E
659.07
'
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLOD
LODLODLODLODLODLO
D
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODTRAVELERS WAY
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
50'X
5
0
'
BUIL
D
I
N
G
ENV
E
L
O
P
E
2,50
0
S
F50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFBUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF15+00 16+00 17+00 18+00 19+00 20+00 20+83.22
15+50 16+50 17+50 18+50 19+50 20+50
F
F
F FFFFFFFFFFFFFFFFFFFFFFFFWWPROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-505 UTILITY PLAN - EJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-505
UTILITY PLAN -
E
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-504PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD LODLOD
LOD
LOD LOD LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LO
D
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
L
O
D
L
O
D
LO
D
LO
D
LO
D
HOPELAND DRIVE
WETLANDS
AREA
848,034 SF
OR
19.47 AC.
AREA
427,379 SF
OR
9.81 AC.9.8
1
A
C
.
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F
60'X6
0
'
BUIL
D
I
N
G
ENVE
L
O
P
E
3,60
0
S
F
60'X60'
BUILDING
ENVELOP
E
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF 60'X
6
0
'
BUIL
D
I
N
G
ENV
E
L
O
P
E
3,60
0
S
F
60
'
X
6
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600 S
F
50
'
X
5
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
2,
5
0
0
S
F
EN
V
E
L
O
P
E
2,
5
0
0
S
F
0+00
1+00
2+00
3+00
4+00 5+00
6+00
7+00
8+0
0
9+
0
0
10
+
0
0
0+50
1+50
2+50
3+50
4+50
5+50
6+50
7+5
0
8+
5
0
9+
5
0
F
F
F
F
F
F FFF F F F F F F F F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FFWWWWAPPROX. LOCATION OF PROP.
CONN. TO EX. FIRE WATER LINE
PROP. 45 DEGREE
BEND FITTINGS (TYP.)
PROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)WE
SNAD83NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-506 UTILITY PLAN - FJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-506
UTILITY PLAN -
F
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-507PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLOD
L
O
D
LODLODLODLODLODLODLODLOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD LOD
LOD
LOD LOD LOD LODLODLODLODLODLODLODHOPELAND DR
I
V
E WETLANDSAREA427,379 SFOR9.81 AC.WETLANDS
AREA
427,379 SF
OR
9.81 AC.
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600
S
F60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
60'X60'
BUILDING
ENVELOPE
60'X60'
BUILDING
ENVELOPE
3,600 SF
60'X60'
BUILDING
ENVELOP
E
3,600 SF 60'X60'BUIL
DI
N
G
ENVEL
OPE
3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'
BUILDING
ENVELOPE
2,500 SF
50'X50'
BUILDING
ENVELOPE
2,500 SF
9+00
10+00
11+00
12+00
13+00
14+00
15+00 16+0017+008+50
9+50
10+50
11+50
12+50
13+50
14+50 15+5016+5017+50F F F
F F F
F F F
F F F
F F F
F F F
F
F
F
F
F FFFFFFFFFFFWWWWWPROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)
W E
SNAD83 NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-507 UTILITY PLAN - GJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-507
UTILITY PLAN -
G
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-506M
A
T
C
H
L
I
N
E
-
S
H
E
E
T
C-
5
0
8
PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
LODLODLODLODLODLOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LODLODLO
D
LO
D
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
D
L
O
D
LO
D
LO
D
LO
D
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODHOPELAND DRIVERAMSHEAD ROADWETLANDS
AREA
17,139 SF
OR
0.39 AC.
WETLANDS
AREA
427,379 SF
OR
9.81 AC.60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF6
0
'
X
6
0
'
60
'
X
6
0
'
B
U
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,
6
0
0
S
F
60'X60'
BUILDI
N
G
ENVEL
O
P
E
3,600 S
F
60'X60'
BUILDING
ENVELOPE
3,600 SF
16
+
0
0
17+00
18+00
19+00
20+00
21+00
22+00
23+00
24+00 24+25.74
1
5
+
5
0
16+
5
0
17+50
18+50
19+50
20+50
21+50
22+50
23+500+001+000+501+50F
F
F
F
F
F
F
F
F F F F F F F F F F F F F F F F F F F F F F
F F
FFFFFFF
WWWW
PROP. 11 DEGREE
BEND FITTINGPROP. 1" PVC DOMESTICSERVICE LINE (TYP.)PROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-508 UTILITY PLAN - HJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-508
UTILITY PLAN -
H
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-507PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
HOPELAND DRIVERIDGEWOOD COURTRAMSHEAD ROADRAMSHEAD ROAD 50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFENVELOPE3,600 SFENVELOPE3,600 SFENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF21+0022+0023+0020+5021+5022+500+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+000+50 1+50 2+50 3+50 4+50 5+50 6+50 7+50 8+50
0+001+000+501+50FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFWWWWPROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)WESNAD83NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-509 UTILITY PLAN - IJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-509
UTILITY PLAN -
I
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-510PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
WESNAD83NAD83LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL
O
DPAXTON PLACEPISGAH COURTRAMSHEAD ROADRAMSHEAD ROAD 50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SFBUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF0+001+002+000+501+500+001+002+000+501+509+00 10+00 11+00 12+00 13+00
14+00
15+00 16+00 17+008+50 9+50 10+50 11+50 12+50 13+50
14+50
15+50 16+50FFFFFFFFFFFF F F
F
F
F
F
F
F
F
F
F FFFFFFFFFFFFFFFFFFWWWWWPROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)PROP. 1" PVC DOMESTICMATCHLINE
-
SHEETC-511DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-510 UTILITY PLAN - JJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-510
UTILITY PLAN -
J
UTP-0
1"=40'
0 40102040MATCHLINE - SHEETC-509PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THE
BUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRAMSHEAD ROA
D
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SFENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE15+0
0
16+00
17+00
18+00
19+00
20+00
21+00
22+00
23+0023+07.43
15+50
16+50 17+50
18+50
19+50
20+50
21+50
22+50
F
F FFFFFFFFFFFF
F
F
F
F
F F F F F F F
F
F
F
F WWWWPROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)
PROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)WESNAD83NAD
83
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-511 UTILITY PLAN - KJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-511
UTILITY PLAN -
K
UTP-0MATCHLINE - SHEETC-5101"=40'
0 40102040
PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 AC
LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD
LOD
LO
D
LO
D
LOD
LOD
LOD
LOD
PISGAH COURT
RAMSHEAD ROAD60'
X
6
0
'
BUI
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF0+00
1+00
2+00
2+69.16
0+50
1+50
2+50
12+0013+0014+0015+0012+5013+5014+50F F FFFFFFFFFFFFFFFFFFFFFFW WPROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)
PROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-512 UTILITY PLAN - LJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-512
UTILITY PLAN -
L
UTP-0
1"=40'
0 40102040
PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THEBUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
LODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LO
D
LO
D
LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODPAXTON PLACE
RAMSHEAD ROADWETLANDS
AREA
123,793 SF
OR
2.84 AC.50'X50'BUILDINGENVELOPE2,500 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60
'BUI
LD
INGENVE
LOPE3,600
SF
60'X60'BUILDINGENVELOPE3,600 SF0+00 1+00 2+00 3+00 3+25.400+50 1+50 2+50
7+008+009+0010+007+508+509+5010+50F F F F F F F FFFFFFFFFFFFFFFFW
W WPROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)
PROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-513 UTILITY PLAN - MJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-513
UTILITY PLAN -
M
UTP-0
1"=40'
0 40102040
PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THE
BUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
S89°56'20"E 1569.80'N/F
OAKMONT DEVELOPMENT PARTNERS LLC
PIN: 0507-53-6396.000
DB 3662, PG 762
14,144,317 SF
OR
324.709 ACLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LODLOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODRIDGEWOOD COURT
RAMSHEAD ROADWETLANDS
AREA
31,240 SF
OR
0.72 AC.60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60
'
X
6
0
'
BU
I
L
D
I
N
G
EN
V
E
L
O
P
E
3,6
0
0
S
F60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF60'X60'BUILDINGENVELOPE3,600 SF3+004+005+006+002+503+504+505+500+00 1+00 2+00 3+00 3+25.400+50 1+50 2+50
FFFFFFFFFFFFFFFFFFFFW
W
WPROP. 8" DIP FIRE
WATER LINE (TYP.)
PROP. FIRE HYDRANT
ASSEMBLY (TYP.)
PROP. 1" PVC DOMESTIC
SERVICE LINE (TYP.)WESNAD83
NAD83DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-UTP-0----->LAYOUT: C-514 UTILITY PLAN - NJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-514
UTILITY PLAN -
N
UTP-0
1"=40'
0 40102040
PROPOSED NOTE
C
SL
W
E
G
OH
T
OR
E
T
EP
EB
TYPICAL NOTE TEXT
UTILITY LEGEND
SAN
#
STM
#
SANITARY
LABEL
STORM
LABEL
SANITARY SEWER
LATERAL
UNDERGROUND
WATER LINE
UNDERGROUND
ELECTRIC LINE
UNDERGROUND
GAS LINE
OVERHEAD
WIRE
UNDERGROUND
TELEPHONE LINE
UNDERGROUND
CABLE LINE
STORM
SEWER
SANITARY
SEWER MAIN
HYDRANT
SANITARY
MANHOLE
STORM
MANHOLE
WATER
METER
WATER
VALVE
GAS
VALVE
GAS
METER
TYPICAL END
SECTION
HEADWALL OR
ENDWALL
YARD
INLET
CURB
INLET
CLEAN
OUT
ELECTRIC
MANHOLE
TELEPHONE
MANHOLE
ELECTRIC
BOX
ELECTRIC
PEDESTAL
MONITORING
WELL
TEST
PIT
S
D
S
WV
WM
SITE DATA CHECKLIST
TOTAL PARCEL AREA ± 325.12 AC
ZONING RESIDENTIAL/
AGRICULTURAL (RA-20R)
ON-SITE DISTURBED AREA ± 16.98 AC
OFF-SITE DISTURBED AREA ± 0.00 AC
TOTAL DISTURBED AREA ± 16.98 AC
UTILITY NOTES:
1.PRIOR TO WORK COMMENCEMENT, CONTRACTOR IS
TO CONTACT LOCAL "NORTH CAROLINA 811" SERVICESFOR LOCATION OF ALL UNDERGROUND UTILITIES.
CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES
PRIOR TO COMMENCEMENT OF WORK WHICH
INCLUDES, BUT NOT LIMITED TO, RELOCATION OF
EXISTING UTILITIES AND OFFSITE IMPROVEMENTS IN
ORDER TO DELIVER THE PROJECT.
2.ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH
HARNETT COUNTY STANDARDS, LATEST EDITION.
3.BUILDING CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL ELECTRICAL SERVICES TO THE
BUILDING, WHICH INCLUDE, BUT NOT LIMITED TO,
TRANSFORMER, TRANSFORMER PADS, METERS, ETC...
4.CONTRACTOR SHALL COMPARE ALL CIVIL ANDBUILDING PLAN SETS PRIOR TO CONSTRUCTION. THE
ENGINEER AND ARCHITECT SHALL BE NOTIFIED OF
ANY UTILITY DISCREPANCIES.
5.CONTRACTOR TO COORDINATE ANY UTILITY POLE
RELOCATIONS DEEMED NECESSARY WITH UTILITY
PROVIDER.
6.WATER LINES ARE SHOWN GRAPHICALLY. IT IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR TO
CONSTRUCT THE LINES PER HARNETT COUNTY
STANDARDS, USING PIPE DEFLECTION AND BENDS AS
REQUIRED.
7.WATER LINE APPURTENANCES ARE SHOWN
GRAPHICALLY. IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE APPURTENANCES TO
AVOID CONFLICT WITH CURB AND GUTTER AND OTHER
UTILITIES.
8.NO WATER METERS WILL BE ALLOWED IN SIDEWALKS
OR DRIVEWAYS.
NOT TO SCALE
CONCRETE ENCASEMENT DETAIL
EX. WATER OR STORM PIPE
10'-0"10'-0"6" MIN.20'-0"
SECTION A-AA
A
CONCRETE ENCASEMENT REQUIRED WHERE
CLEARANCE BETWEEN SANITARY SEWER PIPE
AND WATER OR STORM PIPE IS LESS THAN 18"
EITHER ABOVE OR BELOW SANITARY SEWER.EX. WATER OR
STORM PIPE
CLASS "C"
CONCRETE
ENCASEMENT
SANITARY SEWER
PIPE ONE LENGTH
MIN.
NOT TO SCALE
BOARD ON BOARD FENCE DETAIL
1. ALL LUMBER TO BE PRESSURE TREATED.
2. USE 6"x6" POSTS AT ALL CORNERS (ANGLE POINTS).
8'-0" O.C.6'-0"3'-0" MIN.2'-0"12"Ø MIN.NOTES:
4"x4" WOOD POST
2"x4" STRINGER
(2 TYP.)
1"x6" WOOD SLATS
(VERTICAL)
FINISHED GRADE
CONCRETE BASE
NOT TO SCALE
STOCKADE FENCE DETAIL
1. ALL LUMBER TO BE PRESSURE TREATED.
2. USE 6"x6" POSTS AT ALL CORNERS (ANGLE POINTS).6'-0"3'-0" MIN.2'-0"12"Ø MIN.
8'-0" O.C.
NOTES:
4"x4" WOOD POST
1"x4" WOOD SLATS
(VERTICAL AND
HORIZONTAL)
FINISHED GRADE
CONCRETE BASE
NOT TO SCALE
BOLLARD DETAIL4'-0"3'-0"1'-0"1'-6"
MIN.1.SEE SITE PLAN FOR LOCATION(S).
NOTE:
CONCRETE FILL TO BE ROUNDED
FOR PROPER RUN OFF
4" DIAMETER STEEL PIPE FILLED
W/ CONCRETE PAINTED TRAFFIC
YELLOW AND EMBEDDED IN
CONCRETE BASE
TOP OF ASPHALT OR
CONCRETE SLAB
3000 P.S.I. CONCRETE
NOT TO SCALE
TRAFFIC BARRICADE DETAIL
10'-0" O.C. MIDDLE UNIT(S)9'-0" O.C. END UNIT(S)44"5'-0" (MIN.)20"20"1) SEE PLAN VIEW FOR TRAFFIC BARRIER LOCATION(S).
2) POSTS AND PLANKS SHALL BE PRESSURE TREATED LUMBER.
3) PLANKS SHALL BE PAINTED COMPLETELY WHITE. POSTS SHALL BE
PAINTED WHITE ON ALL SIDES TO WITHIN SIX INCHES (6 IN.) OF THE GROUND LEVEL.
4) GOOD QUALITY OIL BASE EXTERIOR GRADE PAINT MUST BE USED. SIX INCH (6 IN.) HIGH
INTENSITY REFLECTIVE ORANGE AND WHITE STRIPE TAPE ON ONE SIDE FOR THE FULL
LENGTH OF THE BARRICADE.
5) EACH PLANK SHALL BE SECURED TO EACH POST WITH (2)-3
8 IN. X 6-1
2 IN. CARRIAGE
BOLTS OR WITH (2)-716 IN. x 4 IN. LAG SCREWS WITH WASHERS. BOLTS OR SCREWS
ARE TO BE PLACED TWO INCHES (2 IN.) FROM EDGE OF PLANKS.
6)WHERE NECESSARY FOR SAFETY OF PEDESTRIAN TRAFFIC, A FULL EXTENSION OF
THE BARRICADE MAY BE REQUIRED TO THE LIMITS OF THE RIGHT-OF-WAY.
7) WHERE PROVISION MUST BE MADE FOR ACCESS OF EQUIPMENT AND
AUTHORIZED VEHICLES, LOCKABLE GATES MAY BE PROVIDED IN ONE SECTION OF
THE BARRICADE.
NOTES:
4"x4" POSTS, 8'-0" LONG
8" MIN. TO 12" MAX. RAIL W/ 6"
STRIP AND 6" SPACE @ 45°
FINISHED GRADE
NOT TO SCALE
`U' SHAPED BOLLARD DETAIL4'-0"30" BURY4'-4"12" R3" DIA. (SCH. 80) STEEL PIPE
PAINTED TRAFFIC YELLOW
TO BE SEALED
CONCRETE BASE
NOT TO SCALE
TRENCH DRAIN DETAIL
1. SCHEMATIC ONLY. FINAL DESIGN TO PROVIDE H-20 VEHICULAR LOADING.
2. SEE PLAN VIEW AND PROFILES FOR GRATE AND TRENCH INVERT ELEVATIONS.
_'
6"6"VARIES(SEE PROFILE)NOTES:
FINISHED GRADE
FRAME TO BE THOROUGHLY
EMBEDDED IN MORTAR
CAST-IN-PLACE REINFORCED
CONCRETE @ 4,000 P.S.I.
OUTLET PIPE
CONCRETE FOOTING
@ 4,000 P.S.I.
NOT TO SCALE
TRAFFIC RATED CLEANOUT DETAIL
3000 P.S.I. CONCRETE
SAND CUSHION
4" SEWER CLEANOUT CAP
6" PVC ENCASEMENT PIPE
ASPHALT OR
CONCRETE AS
DETERMINED BY
TRAFFIC SURFACE
3,000 P.S.I CONCRETE
TRAFFIC RATED CLEANOUT COVER
2" ASPHALT OR CONCRETE
FINISHED GRADE
18" SQUARE CONCRETE
ENCASEMENT
(3000 P.S.I CONCRETE)4" MAX.18"S
TEST PIT (TO BE HAND DUG)
FINISHED GRADE
1.5' MIN. CLEARANCE
UTILITY CONFLICT
1. CONTRACTOR TO COORDINATE WATERLINE ADJUSTMENT WITH APPROPRIATE INSPECTOR, BASED UPON LOCAL
JURISDICTIONAL REQUIREMENTS AND FIELD CONDITIONS.
2. CONTRACTOR TO HAND DIG TEST PIT AT ANTICIPATED CROSSING LOCATION TO DETERMINE EXISTING WATERLINE
DEPTH, TOTAL WATERLINE DEFLECTION REQUIRED, AND BEST METHOD FOR WATERLINE ADJUSTMENT.
3. VERTICAL BENDS (INSTALLED PER LOCAL STANDARDS) AS REQUIRED.
4. PIPE DEFLECTION AT JOINTS (PER LOCAL STANDARDS)
WATERLINE
ADJUSTMENT
USING FITTINGS
(VERTICAL
BENDS) (SEE
NOTE 3)
WATERLINE
ADJUSTMENT
USING DEFLECTION
AT PIPE JOINTS
(SEE NOTE 4)
EX. MAIN
SEE NOTE 4
ADJUSTMENT TO
EXTEND BEYOND LIMITS
OF CONFLICTS (3' MIN.,
EACH SIDE, CHECK
LOCAL STANDARDS).
NOT TO SCALE
WATERLINE ADJUSTMENT DETAIL
NOTES:
NOT TO SCALE
BOLLARD MOUNTED ADA PARKING SIGN DETAIL
ONE AT EACH ADA SPACE. WHERE ADA SPACES FACE EACH OTHER WITHOUT
WALKWAY, THERE SHALL BE ONE POST WITH SIGNS MOUNTED BOTH SIDES3'-0"7'-0" TO BOTTOM OFLOWEST REQUIRED SIGN1'-6"2'-0"18"12"6"NOTE:
REFLECTIVE ALUMINUM
LEGEND AND BORDER - GREEN
WHITE SYMBOL ON BLUE BACKGROUND
BACKGROUND - WHITE
TYPICAL AT ALL ADA SPACES
THIS SIGN TYPICAL AT ALL "VAN
ACCESSIBLE" PARKING SPACES
PENALTY SIGN WITH WORDING AS
REQUIRED BY STATE OR LOCAL LAW
GALVANIZED "U" CHANNEL POST
4" DIA. SCH. 40 GALVANIZED STEEL PIPE
BOLLARD PAINTED OSHA YELLOW FILLED
WITH CONCRETE
PAINT CONCRETE BLACK AFTER
CURING AT ASPHALT LOCATIONS
4000 PSI CONCRETE
NOT TO SCALE
EXAMPLE ONE
NOT TO SCALE
EXAMPLE TWO
0.50% MIN
LIMITS OF
PROP PVMT
(SEE NOTE 4)
1.0%
MI
N
1.
0
%
M
I
N
0.50% MIN
NOT TO SCALE
EXAMPLE THREE
FLUME
(SEE NOTE 5)
EXAMPLE 3
NOTES:
1. CONTRACTOR TO INSTALL CURB AND GUTTER AT ELEVATION OF EXISTING PAVEMENT (ELEVATION AT EDGE
OF GUTTER PAN MATCHES ELEVATION AT EXISTING PAVEMENT, UNLESS PLANS AND/OR SCHEMATICS INDICATE
DIFFERENTLY.
2. CONTRACTOR TO PROVIDE GUTTER PANS (COLLECTOR/SPILL) PER GRADING PLAN. SHADED GUTTER PAN
REPRESENTS FULL SPILL SECTION, NON-SHADED IS COLLECTOR. CONTRACTOR TO PROVIDE 3 FOOT
TRANSITIONS BETWEEN SPILL AND COLLECTOR SECTIONS.
3. PLAN INTENT IS TO PROVIDE A MINIMUM SLOPE OF 0.50% ALONG COLLECTOR CURB. IF FIELD CONDITIONS
AND/OR PLAN REPRESENTATION DOES NOT PROVIDE MINIMUM SLOPE REQUIREMENTS, CONTRACTOR IS TO
CONTACT ENGINEER PRIOR TO POURING CURB AND GUTTER. BOHLER SHALL BE HELD HARMLESS FOR ANY
CURB AND GUTTER POURED THAT DOES NOT MEET MINIMUM REQUIREMENTS.
4. IN THOSE SITUATIONS WHERE RE-GRADING OF PARKING AND PAVEMENT REMOVAL IS NECESSARY (SEE
EXAMPLE 2), THE CONTRACTOR IS TO VERIFY THAT THE RESULTANT GRADIENT AT THE HIGH SIDE OF THE
ISLAND PROVIDES 1% PAVEMENT SLOPE, PER PLAN INTENT.
5. IN ISLANDS WHERE FLUMES ARE INDICATED, THE CONTRACTOR SHALL PROVIDE A FLAT BOTTOMED FLUME
AT THE SPECIFIED WIDTH. MINIMUM FLUME SLOPE SHALL BE 0.50%.
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-901 SITE DETAILSJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-901
SITE DETAILS
NOT TO SCALE
ASPHALT TRAIL DETAIL
__' (TYP.)6"6"3:1 MAX.
3:
1
M
A
X
.
3:
1
M
A
X
.3:1 MAX.
1.TRAIL CROSS SLOPE NOT TO EXCEED 2.00%.
NOTE:
2' MIN. CLEAR ZONE
(TYP. LT. & RT.)
COMPACTED SUBGRADE
(PER GEOTECHNICAL
REPORT)4" COMPACTED
21-A STONE
2" COMPACTED
SM-2A ASPHALT
NOT TO SCALE
HEAVY DUTY ASPHALT PAVEMENT SECTION
1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF __ PER GEOTECHNICAL REPORT
PREPARED BY ________, ENTITLED _______, DATED _______ (PROJECT #____). FINAL
DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLE ON COMPACTED SUB-BASE.
NOTE:
__" ASPHALT SURFACE COURSE (____)
__" ASPHALT BINDER COURSE (____)
__" COMPACTED STONE BASE (____)
COMPACTED SUBGRADE
(PER GEOTECHNICAL REPORT)
NOT TO SCALE
PAVEMENT WIDENING DETAIL
SLOPE
VARIES
PROP.
PAVEMENT
EX.
PAVEMENT
SAWCUT LINE1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF __ PER GEOTECHNICAL
REPORT PREPARED BY ________, ENTITLED _______, DATED _______ (PROJECT
#____). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLE ON
COMPACTED SUB-BASE.
NOTE:
_" FINISH ASPHALT
BIT. CONC. _______
_" BASE COURSE
____________
_" STONE BASE
____________
TACK COAT
(APPLIED AT A RATE
OF 0.2 GALLONS/S.Y.)
PROP. 1 1/2" MILL
AND OVERLAY
EX. ASPHALT
TO REMAIN
MEET EX. PAVEMENT FLUSH
NOT TO SCALE
STANDARD DUTY ASPHALT PAVEMENT SECTION
1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF __ PER GEOTECHNICAL
REPORT PREPARED BY ________, ENTITLED _______, DATED _______ (PROJECT
#____). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLE ON
COMPACTED SUB-BASE.
NOTE:
__" ASPHALT SURFACE COURSE (____)
__" ASPHALT BINDER COURSE (____)
__" COMPACTED STONE BASE (____)
COMPACTED SUBGRADE
(PER GEOTECHNICAL REPORT)
NOT TO SCALE
CONCRETE-TO-ASPHALT DETAIL
TACK COAT
(APPLIED AT A RATE
OF 0.2 GALLONS/S.Y.)
PAVEMENT SURFACE
(SEE PAVEMENT DETAIL)
CONCRETE PAVEMENT SECTION
NOT TO SCALE
CONCRETE DOWELING DETAIL
EX. CONC.
PAVEMENT
PROP. CONC.
PAVEMENT
8-1/2"
1.CONTRACTOR TO BLOW OUT DUST FROM DRILLED HOLES PRIOR TO APPLYING
GROUT.
NOTE:
EXPANSION JOINT MATERIAL
EPOXY COATED
DOWEL @ 18" O.C.
GROUT
NOT TO SCALE
CONCRETE SIDEWALK DETAIL
VARIES
3:1 MAX.
3:
1
M
A
X
.
3:
1
M
A
X
.3:1 MAX.
1. EXPANSION JOINTS 1/2" WIDE PREMOLDED BIT. MATERIAL SHALL BE INSTALLED
AT 30' INTERVALS, CRACK CONTROL JOINTS TO BE SPACED AT INTERVALS EQUAL
TO SIDEWALK WIDTH.
2% MAX. CROSS SLOPE
NOTE:
COMPACTED SUBGRADE (PER
GEOTECHNICAL REPORT)4" THICK, COMPACTED
STONE BASE (TYPE 2a)
4" CLASS A CONCRETE
(3000 P.S.I. @ 28 DAYS)
2' MIN. CLEAR ZONE
(TYP., LT. & RT.)
NOT TO SCALE
CURB BREAK DETAIL
3' TAPER _' CURB
BREAK
3' TAPER
GUTTER PAN
3' RIP-RAP PAD
3' TAPER
_' CURB
BREAK 3' TAPER
ELEVATION
PLAN
PAVED SURFACE/ CONC. PAD
STD. CURB (PER SITE PLAN)
1" RADIUS
FULL HEIGHT CURB _' CURB TAPER
2"
NOT TO SCALE
CURB TAPER DETAIL
PAVEMENT SURFACE
1" RADIUS
NOT TO SCALE
HEADER CURB DETAIL
4"
6"18"1.EXPANSION JOINTS TO BE INSTALLED AT 20' INTERVALS.
2.THIS ITEM MAY BE PRECAST OR CAST IN PLACE.
3. CONCRETE TO BE CLASS A3 IF CAST IN PLACE OR 4000 P.S.I. IF PRECAST.
NOTES:
PAVEMENT SURFACE
(SEE PAVEMENT DETAIL)
6" REVEAL
2" RADIUS1/4" RADIUS
FINISHED GRADE
NOT TO SCALE
HEAVY DUTY CONCRETE SECTION
1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF __ PER GEOTECHNICAL
REPORT PREPARED BY ________, ENTITLED _______, DATED _______ (PROJECT
#____). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLE ON
COMPACTED SUB-BASE.
NOTE:
6x6 WWM (10 GA.)
____" CONCRETE __" COMPACTED STONE BASE
COMPACTED SUBGRADE
(PER GEOTECHNICAL REPORT)
NOT TO SCALE
MOUNTABLE CURB DETAIL
1.EXPANSION JOINTS TO BE INSTALLED AT 20' INTERVALS.
2.THIS ITEM MAY BE PRECAST OR CAST IN PLACE.
3.CONCRETE TO BE CLASS A3 IF CAST IN PLACE OR 4000 P.S.I. IF PRECAST.
4. WHEN THIS STANDARD IS TO BE TIED INTO EXISTING BARRIER CURB, THE
TRANSITION IS TO BE MADE WITHIN 10' OR THE CHANGE IN STANDARDS MADE
AT REGULAR OPENINGS.
2"5"3"1"11"7"2'-0"7"1":1'
NOTES:
PAVEMENT SURFACE
(SEE PAVEMENT DETAIL)
NOT TO SCALE
STANDARD DUTY CONCRETE SECTION
_____" CONCRETE __" COMPACTED STONE BASE
COMPACTED SUBGRADE
(PER GEOTECHNICAL REPORT)
6x6 WWM (10 GA.)
1. SECTION SHOWN IS BASED ON AN ANTICIPATED CBR OF __ PER GEOTECHNICAL
REPORT PREPARED BY ________, ENTITLED _______, DATED _______ (PROJECT
#____). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE AVAILABLE ON
COMPACTED SUB-BASE.
NOTE:
12"
1:12
18"
NOT TO SCALE
MOUNTABLE CURB & GUTTER DETAIL
1:12
(ROLL TOP-REVERSE)
18"
24"12"24"
(ROLL TOP)
1. CONCRETE FOR CURBING SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S.I. @ 28 DAYS.
2. CONSTRUCTION STAKING FOR CURB INSTALLATION SHALL BE REFERENCED (CUT OR FILL) TO THE TOP OF CURB.
3. AT CONTRACTOR'S OPTION, THE GUTTER THICKNESS MAY BE INCREASED AT THE EDGE OF PAVEMENT TO MAKE BOTTOM OF GUTTER CONTIGUOUS WITH BOTTOM OF ASPHALT PAVEMENT.
4. CONTRACTION JOINTS SHALL BE PLACED @ 10'-0" O.C. TOOLED 1/4" (±1/16") WIDE, 1" DEEP. EXPANSION JOINTS SHALL BE PLACED @ 40'-0" INTERVALS, MAXIMUM, AND ALL P.C.'S.
6" CURB LINE
1.5"12"7"7"2"
1.5"
6"
TO CURB
12"NOTES:
R1.25'
R1.50'
R=15"
R=18"
12:1 MAX.
SLOPE
5'-0"
MIN.
12:1 MAX.
SLOPE
NOT TO SCALE
ADA ACCESSIBLE RAMP DETAIL
ADA ACCESSIBLE RAMP CONSTRUCTION SHALL CONFORM TO CURRENT ADA
ACCESSIBLE GUIDELINES.
NOTE:
TRUNCATED DOME PATTERN
EDGE OF CURB
1:1
2
SL
O
P
E
1:12
SLOPE
3' MI
N
.
NOT TO SCALE
ADA ACCESSIBLE RAMP DETAIL
1. ADA ACCESSIBLE RAMP CONSTRUCTION SHALL CONFORM TO CURRENT
ADA ACCESSIBLE GUIDELINES.
3' MIN.
NOTE:
TRUNCATED
DOME PATTERN
MAX
1:12 SLOPE
MA
X
MAX
FLUSH CURB SEE SITE PLAN
FOR DIMENSION
MAX 2% IN ANY DIRECTION
AT LANDING
NOT TO SCALE
CONCRETE CURB & GUTTER DETAIL
2'-0"
6"1"6"1"PAVEMENT DIMENSION(S) ON PLAN VIEW
REFER TO FACE OF CURB
1. CONCRETE FOR CURBING SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S.I. @ 28 DAYS.
2. CONSTRUCTION STAKING FOR CURB INSTALLATION SHALL BE REFERENCED (CUT OR FILL) TO THE TOP OF CURB.
3. AT CONTRACTOR'S OPTION, THE GUTTER THICKNESS MAY BE INCREASED AT THE EDGE OF PAVEMENT TO MAKE BOTTOM OF GUTTER CONTIGUOUS WITH BOTTOM OF ASPHALT PAVEMENT.
4. CONTRACTION JOINTS SHALL BE PLACED @ 10'-0" O.C. TOOLED 1/4" (±1/16") WIDE, 1" DEEP. EXPANSION JOINTS SHALL BE PLACED @ 40'-0" INTERVALS, MAXIMUM, AND ALL P.C.'S.
5. GUTTER PAN SLOPE TO BE ADJUSTED WITHIN ACCESSIBLE PARKING SPACES TO MATCH SLOPE BETWEEN SPOT ELEVATIONS.
2'-0"
6"
1"1"6"1"SPILL CURB & GUTTER COLLECTOR CURB & GUTTER6"PAVEMENT DIMENSION(S) ON PLAN
VIEW REFER TO FACE OF CURB
5"NOTES:
1-1/2"R 1-1/2"R
1
1
2% MAX. SLOPE17"5"
1.CONCRETE TO BE 4000 P.S.I. @ 28 DAYS.
NOTE:
4" COMPACTED 21-A STONE
4" CONCRETE WALK
W/6x6 WWM (10 GA)
PROPOSED PAVEMENT
(SEE PAVEMENT DETAIL)
TACK COAT
(APPLIED @ 0.2
GALLONS/S.Y.)
NOT TO SCALE
MONOLITHIC CURB & FLUSH SIDEWALK
DETAIL
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-902 SITE DETAILSJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-902
SITE DETAILS
MAXIMUM RAMP SLOPE AND RISE FOR EXISTING SITES, BUILDINGS, AND FACILITIES
SLOPE
STEEPER THAN 1:10 BUT NOT STEEPER THAN 1:8
STEEPER THAN 1:12 BUT NOT STEEPER THAN 1:10
MAXIMUM RISE
3 INCHES (75MM)
6 INCHES (150MM)
"A"
ELEVATION
DETAIL "A"NOT TO SCALE
RETROFIT ADA RAMP AND HANDRAIL DETAIL
HORIZONTAL RUN 60" MINIMUM LANDING
60" MINIMUM LANDING
RISE"LESSTHAN"4"34"-38"1'-0"
1'-0"34"-38"36" CLEAR (MIN.)
1-1/2" MIN.
1. RAMPS AND HANDRAILS TO BE IN COMPLIANCE WITH CURRENT ADA GUIDELINES.
2. HANDRAILS WITH CIRCULAR CROSS SECTIONS SHALL BE 1.25" TO 2" OUTSIDE DIAMETER.
3. NON-CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER OF 4" TO 6.25" AND A MAXIMUM CROSS SECTION
DIMENSION OF 2.25". (SEE ADA GUIDELINES)
4. SIDEWALK TO EXTEND 4" BEYOND OUTSIDE OF RAILING WHEN A BOTTOM RAIL IS PROVIDED OR 12" BEYOND WHEN
NO BOTTOM RAIL IS PROVIDED.
SEE NOTE 4
3"MIN.1'-0"8" SQUAREVARIESNOTE: A SLOPE STEEPER THAN 1:8 IS PROHIBITED
BOTTOM RAIL
NOTES:
HANDRAIL
SET PIPE IN
CONC. FOOTING
HANDRAIL
"A"
ELEVATION
DETAIL "A"NOT TO SCALE
TYPICAL ADA RAMP AND HANDRAIL DETAIL
30' MAX. HORIZONTAL (RUN)60" MINIMUM LANDING
60" MINIMUM
LANDING
2'-6"MAX.RISE4"34"-38"1'-0"
1'-0"34"-38"36" CLEAR (MIN.)
1-1/2" MIN. WALL
MOUNT SPACING
1. RAMPS AND HANDRAILS TO BE IN COMPLIANCE WITH CURRENT ADA GUIDELINES.
2. HANDRAILS WITH CIRCULAR CROSS SECTIONS SHALL BE 1.25" TO 2" OUTSIDE DIAMETER.
3. NON-CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER OF 4" TO 6.25" AND A MAXIMUM CROSS SECTION
DIMENSION OF 2.25". (SEE ADA GUIDELINES)
4. SIDEWALK TO EXTEND 4" BEYOND OUTSIDE OF RAILING WHEN A BOTTOM RAIL IS PROVIDED OR 12" BEYOND
WHEN NO BOTTOM RAIL IS PROVIDED.3"MIN.1'-0"8" SQUAREVARIES2.08% MAX.
SLOPE
SEE NOTE 4
BOTTOM RAIL
NOTES:
HANDRAIL
SET PIPE IN
CONC. FOOTING
HANDRAIL
NOT TO SCALE
STREET NAME TYPICAL SECTION (A)
1'__'
__'
__'
SIDEWALK/TRAIL
__'
2.08%
2.08%
CLPL
3:1 MAX
.
S
L
O
P
E
3:1 M
A
X
.
S
L
O
P
E
COMPACTED SUBGRADE
(PER GEOTECHNICAL REPORT)
SAWCUT ALONG EXISTING EDGE OF
PAVEMENT (1' MIN. REMOVAL) AND
APPLY TACK COAT (.2 GAL./SY.)
EXISTING
PAVEMENT
_" COMPACTED STONE BASE ( _ )
_" ASPHALT BINDER COURSE ( _ )
_" ASPHALT SURFACE COURSE ( _ )
PROVIDE FULL SPEC.
SEE SIDEWALK/TRAIL
DETAIL
NOT TO SCALE
STREET NAME TYPICAL SECTION (B)
1'__'
__'
__'
SIDEWALK/TRAIL
__'
_" COMPACTED STONE BASE ( _ )
COMPACTED SUBGRADE
(PER GEOTECHNICAL REPORT)
3:1 MAX
.
S
L
O
P
E
3:1 M
A
X
.
S
L
O
P
E
CL
PL
PROPOSED WIDENING
EXISTING PAVEMENT
(MILL AND OVERLAY)
2.08%
2.08%
EXISTING
PAVEMENT
1-1
2" MILLING @ CENTERLINE
APPLY TACK COAT AT
A RATE OF 0.2 GAL./SY.
_" ASPHALT BINDER COURSE ( _ )
_" ASPHALT SURFACE COURSE ( _ )
PROVIDE FULL SPEC.
SEE SIDEWALK/TRAIL DETAIL
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C-903 SITE DETAILSJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC-903
SITE DETAILS
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C -904 STORM DETAILSJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC -904
STORM
DETAILS
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C -905 SANITARY DETAILSJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC -905
SANITARY
DETAILS
NOTE:
FORCE MAINS 8"Ø AND SMALLER SHALL
HAVE MINIMUM OF 3' COVER. FORCE
MAINS LARGER THAN 8"Ø SHALL HAVE A
MINIMUM OF 3'-6" COVER.
ELECTRONIC MARKER BALLS AT 100' ON
CENTER & AT BENDS. MARKER BALLS SHALL
BE INSTALLED AT 1 1/2 TO 2' DEEP.
1/2 PIPE O.D.
24" + O.D. MAX.
12" + O.D. MIN.
PIPE
O.D.
SHAPED SUBGRADE
SHALL PROVIDE BEARING
ALONG ENTIRE LENGTH
OF PIPE BARREL
BEDDED PIPE
UNDISTURBED EARTH
NOTE: MARKER BALLS SHALL BE INSTALLED
CONCURRENTLY WITH PIPE. MARKER
BALLS SHALL NOT BE INSTALLED AFTER
TRENCH HAS BEEN COMPLETELY
BACKFILLED.
HAND PLACED
DENSELY COMPACTED
BACKFILL TO 1 FT.
ABOVE TOP OF PIPE
FORCE MAIN
PIPE LAYING
CONDITION "E"
NOTE: PIPE SHALL BE BEDDED UP TO
SPRING LINE AND MINIMUM 4" BELOW
BOTTOM OF PIPE WHEN WET AREAS ARE
ENCOUNTERED.
STYPICAL PIPE LAYING CONDITION DETAILS
18
COVER
FRAME & COVER
FRAME
USE MIN. 4 EA. 3/8" ANCHOR
BOLTS TO SECURE FRAME TO MANHOLE
23.5"
RAM-NEK
SEALANT
2"1"
BASE COURSEBASE COURSE
FINISHED GRADE
1.5" MIN.
6" MIN.
COMPACTED FILLCOMPACTED FILL
STD. MANHOLE
RING & COVER
SMANHOLE FRAME & COVER DETAIL
20SANITARYSEWERMADE IN USA
PRESSURE RELEASE HOLES
NOTE:
CONCRETE ENCASEMENT SHALL ONLY BE
USED IN AREAS WHERE COVER IS TO BE FLUSH
WITH PAVEMENT OR CONCRETE. CONCRETE
ENCASEMENT SHALL NOT BE USED IN
NON-TRAFFIC AREAS AND ABOVE GRADE
INSTALLATIONS.
TYPICAL PRESSURE RELEASE
COVER
FRAME & COVER
FRAME
NOTE:
CONCRETE ENCASEMENT SHALL ONLY BE
USED IN AREAS WHERE COVER IS TO BE FLUSH
WITH PAVEMENT OR CONCRETE. CONCRETE
ENCASEMENT SHALL NOT BE USED IN
NON-TRAFFIC AREAS AND ABOVE GRADE
INSTALLATIONS.
USE MIN. 4 EA. 3/8" ANCHOR
BOLTS TO SECURE FRAME TO MANHOLE
23.5"
RAM-NEK
SEALANT
2"1"
BASE COURSEBASE COURSE
FINISHED GRADE
1.5" MIN.
6" MIN.
COMPACTED FILLCOMPACTED FILL
STD. MANHOLE
RING & COVERSANITARYSEWERMADE IN USA
SFRAME & COVER DETAIL
21
TYPICAL STANDARD MANHOLE
STD. MANHOLE
RING & COVER
LABELED
"SANITARY SEWER"
USE MIN. 4 EA. 3/8" ANCHOR
BOLTS TO SECURE FRAME TO MANHOLE
IN NON-TRAFFIC AREAS OR RAISED MANHOLES
COVER
FRAME & COVER
FRAME
USE MIN. 4 EA. 3/8" ANCHOR
BOLTS TO SECURE FRAME TO MANHOLE
23.5"
RAM-NEK
SEALANT
2"1"
BASE COURSEBASE COURSE
FINISHED GRADE
1.5" MIN.
6" MIN.
COMPACTED FILLCOMPACTED FILL
STD. MANHOLE
RING & COVER
SFRAME & COVER DETAIL
22SANITARYSEWERMADE IN USA
SETTING LOCATION OF LOCKING BOLTS
USE MIN. 4 EA. 3/8" ANCHOR BOLTS
TYPICAL LOCKABLE MANHOLE
STYPICAL VENTED MANHOLE DETAIL
FLAT TOP MANHOLE
VENT
NOTE:
VENT TOP TO BE 1' ABOVE
100 YEAR FLOOD ELEV.
CONE TOP MANHOLE
BUG
SCREEN
TYPE 316
stainless steel
FINISHED GRADE
VARIES
FINISHED GRADE VARIES
STD. MANHOLE
FRAME & COVER
3" SCHEDULE 80 PVC
3" SCHEDULE 80 PVC
NON-SHRINK
GROUT
STD. MANHOLE
FRAME & COVER
3" PVC WALL
SLEEVE
3" PVC WALL
SLEEVE
NON-SHRINK
GROUT
23
USE 4 EA. 38" ANCHOR BOLTS
TO BOLT FRAME TO SPACER.
USE ROPE MASTIC SEAL
BETWEEN FRAME AND SPACER.
STANDARD MANHOLE
RING AND COVER
MANHOLE STEPS
16" O.C.
BRICK & MORTAR INVERT
MIN. 6" GRAVEL BEDDING
ECCENTRIC
TAPER UNIT
RISER UNIT
BASE UNIT
4' DIA. MIN.5"
2'-0", 3'-0"
OR 4'-0"
8" MAX. FOR SPACER
8"
JOINTS SHALL BE SEALED
WITH A RUBBER O-RING
GASKET OR ROPE MASTIC SEAL.
CEMENT GROUT ALL JOINTS
INSIDE AND OUT
112":12" SLOPEON ALL INVERTS
EXTENDED BASE
(REQUIRED OVER 12')
STYPICAL STANDARD PRECAST CONCRETE MANHOLE DETAIL
NOTE:
IN NON-TRAFFIC AREAS,TOP OF FRAME AND COVER SHALL BE
INSTALLED AT LEAST 2 FT ABOVE FINISH GRADE OR
AT LEAST 1 FT ABOVE FLOOD STAGE.
24
SEE DETAIL S-25
1. SEE DETAIL S-28 FOR TYPICAL INVERT.
NOTES:
WIDTH AS
REQUIRED
12" MIN.
TYPICAL OUTSIDE DROP MANHOLE DETAIL S
NOTE:
1. PIPE SIZE FOR DROP TO EQUAL INFLOW
SEWER PIPE SIZE.
2. FITTINGS FOR DROPS SHALL BE C-900 OR
SCHEDULE 40 PVC.
3. SAW-CUT OR DRILL ALL HOLES FOR PIPE AND
BOLTS.
4. DROP-MANHOLE MANDATORY WHEN
DIFFERENTIAL BETWEEN INVERTS IS
GREATER THAN 24".
STANDARD MANHOLE
RING & COVER
STANDARD PRECAST MANHOLE
4'-0" MIN. DIA.
TEE
RUBBER BOOT
MANHOLE STEPS
GROUT
TO SLOPE
90° BEND
RUBBER BOOT
RUBBER BOOT
CONCRETE FILL
26
SEE DETAIL S-25
5. SEE DETAIL S-28 FOR TYPICAL INVERT.
COPOLYMER POLYPROPYLENE
PLASTIC M.A. INDUSTRIES MODEL
PSI-PF OR APPROVED EQUAL.
918"
338"114"
118"918"
103 4"
12"
TYPICAL POLYPROPYLENE PLASTIC STEP DETAIL S
27FLOWSLOPE
112":12"
S
L
O
P
E112":
1
2
"
TYPICAL MANHOLE INVERT DETAIL S
NOTE:
1. THE FLOW CHANNEL THROUGH MANHOLES SHOULD BE MADE
TO CONFORM IN SHAPE AND SLOPE TO THE SEWER MAIN.
2. CHANGE IN DIRECTION OF THE CHANNEL SHALL NOT BE
EXCEED 90 DEGREES.
28
3. SEE DETAIL S-24 FOR TYPICAL MANHOLE STRUCTURE.
TYPICAL SEWER SERVICE CONNECTION DETAIL S
4" PVC VERTICAL
4" SWEEP WYE
SERVICE LINE
SANITARY SEWER
MAIN
TEE BRANCH
SLOPE MIN. 1%
PLUG
STOP AT R/W
45°SANITARY TEE
(SAME MATERIAL
AS MAIN)
CLEANOUT PLUG AND CAP
NOTE:
EASEMENT SHALL BE PROVIDED FOR SERVICE
CONNECTION WHERE SERVICE CONNECTION IS PLACED
OUTSIDE OF R/W DUE TO PHYSICAL CONSTRAINTS.CAST IRON VALVE BOX
W/ CHARLOTTE HUB
3'-0"
MAX.
1' inside
RW
29
IN-LINE WYE
FITTING FOR NEW
CONSTRUCTION OR
ROMAC-CB SADDLE
FOR TAP ON EXISTING
SANITARY SEWER MAIN.
BRASS
(DO NOT GLUE)
SCH 40 PVC VERTICAL
SCH 40 PVC
SCH 40 PVC
12" MIN.12" MIN.
8" MIN.
24" MIN. CLEARANCE
TRENCH WALL
UNIFORM STONE #57
UNDISTURBED SOIL
D.I. SANITARY
SEWER
EXISTING STORM PIPE
NOTE:
1 EA. JOINT OF DUCTILE IRON PIPE SHALL BE CENTERED
UNDER STORM PIPE FOR ALL CROSSINGS.
TYPICAL STORM SEWER CROSSING
S
31
FOR SANITARY SEWER DETAIL
12" MIN.12" MIN.
8" MIN.
24" MIN. CLEARANCE
TRENCH WALL
UNIFORM STONE #57
UNDISTURBED SOIL
D.I. SANITARY
SEWER
EXISTING WATER LINE
TYPICAL WATER LINE CROSSING
S
32
FOR SANITARY SEWER DETAIL
NOTE:
1 EA. JOINT OF DUCTILE IRON PIPE SHALL BE CENTERED
UNDER WATER LINE FOR ALL CROSSINGS.
TYPICAL LAYING CONDITIONS DETAIL S
33
SANITARY SEWER
(0'-8' DEPTH)
PIPE LAYING
CONDITION "A"
PIPE
O.D.
HAND PLACED
DENSELY COMPACTED
BACKFILL TO 1 FT.
ABOVE TOP OF PIPE
BEDDED PIPE
MINIMUM STONE
EMBEDMENT AS
INDICATED. GREATER IF
REQUIRED BY
MANUFACTURER 12 PIPE
O.D.
24" + O.D. MAX.
12" + O.D. MIN.
D/8≥3"D/4
D/2D/8≥3"
24" + O.D. MAX.
12" + O.D. MIN.
12 PIPE
O.D.
MINIMUM STONE
EMBEDMENT AS
INDICATED. GREATER IF
REQUIRED BY
MANUFACTURER
BEDDED PIPE
HAND PLACED
DENSELY COMPACTED
BACKFILL TO 1 FT.
ABOVE TOP OF PIPE
PIPE
O.D.
SANITARY SEWER
(<8'-16' DEPTH)
PIPE LAYING
CONDITION "B"
SHAPED STONE
TO PROVIDE BEARING
ALONG ENTIRE LENGTH
OF PIPE BARREL
SHAPED STONE
TO PROVIDE BEARING
ALONG ENTIRE LENGTH
OF PIPE BARREL
STYPICAL PIPE LAYING CONDITION DETAIL
16
SANITARY SEWER
(DUCTILE IRON ONLY)
(0'-16' DEPTH)
PIPE LAYING
CONDITION "C"
PIPE
O.D.
HAND PLACED
DENSELY COMPACTED
BACKFILL TO 1 FT.
ABOVE TOP OF PIPE
BEDDED PIPE
12 PIPE
O.D.24" + O.D. MAX.
12" + O.D. MIN.
D/2D/8≥3"
24" + O.D. MAX.
12" + O.D. MIN.
12 PIPE
O.D.
MINIMUM STONE
EMBEDMENT AS
INDICATED. GREATER IF
REQUIRED BY
MANUFACTURER
BEDDED PIPE
HAND PLACED
DENSELY COMPACTED
BACKFILL TO 1 FT.
ABOVE TOP OF PIPE
PIPE
O.D.
SANITARY SEWER
(DUCTILE IRON ONLY)
(>16' DEPTH)
PIPE LAYING
CONDITION "D"
SHAPED SUBGRADE
TO PROVIDE BEARING
ALONG ENTIRE LENGTH
OF PIPE BARREL
SHAPED STONE
TO PROVIDE BEARING
ALONG ENTIRE LENGTH
OF PIPE BARREL
STYPICAL PIPE LAYING CONDITION DETAIL
17
SDP-0
DISCLAIMERPROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
CAD I.D.:
PROJECT:
FOR
H:\2020\NCR201044\DRAWINGS\PLAN SETS\NCR201044-SDP-0----->LAYOUT: C -906 WATER DETAILSJATHIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY
REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION
DOCUMENT UNLESS INDICATED OTHERWISE.
SHEET NUMBER:
SHEET TITLE:
NCR201044
AD
GZ
04/06/2021
OAKMONT
DEVELOPMENT
PARTNERS, LLC.
PROPOSED
SUBDIVISION
DOCS ROAD & EXECUTIVE DRIVE
BARBECUE TOWNSHIP
HARNETT COUNTY, NC
PARCEL ID: 0507-53-6396.000
ALWAYS CALL 811
It's fast. It's free. It's the law.
ORG. DATE -
REVISIONS
REV DATE COMMENT DRAWN BY
CHECKED BY
04/06/2021
NOT APPROVED FOR
CONSTRUCTION
NCBELS P-1132
4130 PARKLAKE AVENUE, SUITE 130
RALEIGH, NC 27612
Phone:(919) 578-9000
NC@BohlerEng.comTM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTENAUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES©SITE CIVIL AND CONSULTING ENGINEERINGLAND SURVEYINGPROGRAM MANAGEMENTLANDSCAPE ARCHITECTURESUSTAINABLE DESIGNPERMITTING SERVICESTRANSPORTATION SERVICESBOHLER Apr 06, 2021OAKMONT
SUBDIVISION PHASE III
PLAT PLANS
SEAL
048395
GA
R
Y J . Z U R A W SKIENGI N E E RPROFESSIO
N
ALNORT H CAROLI
N
AC -906
WATER
DETAILS
TYPICAL VALVE MARKER DETAIL W
PAINT MARKER BLUE AFTER INSTALLATION
NOTES: 1
2"
1"
TYPICAL VALVE BOX DETAIL W
2
TYPICAL TRACER WIRE INSTALLATION DETAIL W
3
ADJUSTABLE
VALVE BOX
BRICK TO
SUPPORT
VALVE BOX
MECHANICAL JOINT
WITH GRIP RING
36" THREADED BRASS
PIPE NIPPLE 2" DIA CONCRETE BLOCKING
MIN. 1/3 C.Y. AT 3000 P.S.I.
PRECAST CONCRETE
PROTECTION RING
SQUARE HEAD
VALVE NUT ONLY
MIN 1/5" OF PROTECTION
RING TO BE EXPOSED
TAMPED BACKFILL
THREADED
COUPLING
WATER MAIN
2"
1"
BACKFILL TO EDGE
FINISHED GRADE
MIN 6"
MIN OF 24" THREADED
BRASS PIPE NIPPLE 2" DIA
OR LONGER TO BRING PIPE
UP TO FINISHED GRADE2" BRASS
THREADED
PIPE NIPPLE
MIN 18"
END CAP ON PLUG
WITH 2" THREADED PORT
NOTE: SEE TYPICAL VALVE BOX DETAIL
FOR BRICK INSTALLATION
TYPICAL PERMANENT BLOW-OFF ASSEMBLY DETAIL W
4
OPENTYPICAL TAPPING SLEEVE AND VALVE ASSEMBLY DETAIL
TAPPING SLEEVE SHALL BE ROMAC BRAND
MODEL SST MANUFACTURED WITH 316 STAINLESS STEEL.
W
5
TYPICAL FIRE HYDRANT INSTALLATION DETAIL W
6
TYPICAL THRUST BLOCK DETAIL W
7 TYPICAL BORING & JACKING DETAIL W
8
TYPICAL TRENCH IN BITUMINOUS SURFACE AREAS DETAIL W
10
TYPICAL DOMESTIC WATER SERVICE INSTALLATION DETAIL
SINGLE 3/4" SERVICES
2" PVC SLEEVE W/ 3/4" CARRIER
12" MIN
NOTES:
1. INSTALL METER AT R/W
2. "TWO (2)-3/4" SERVICE LINES MUST BE INSTALLED
INSIDE A 2" SLEEVE."
5. SEE DETAIL FOR SERVICE MATERIAL AND METER
SETTING
4. SLEEVES SHOULD BE SCHEDULE 40 PVC PIPE.
3. "TWO (2)-1" SERVICE LINES MUST BE INSTALLED
INSIDE A 3" SLEEVE."
1'
6. SERVICE LINE SHALL BE 3' BELOW FINISHED GRADE
OF DITCHES.
6'
METERS SHOULD BE
INSTALLED 3' OFF
PROPERTY LINE
W
12
7. CONDUIT MUST EXTEND PAST PREPOSED SIDEWALK.
SIDEWALK
USING TAPPING SADDLE DETAIL
TYPICAL WATER SERVICE CONNECTION
W
13
TYPICAL 3/4" METER SETTER INSTALLATION DETAIL
9"
W
14
VALVE BOX
24"x18" RECTANGULAR
17"
18"
24"
3 1/2"
18"
12"
A BA
ELEVATION
ISOMETRIC
PLAN
TYPICAL METER BOX DETAIL FOR 3/4" SERVICE
CAST IRON
16 3/4"
11"SIGMAWATERMETER
W
15