Loading...
HomeMy WebLinkAboutRevised 2-19-19Civil Engineering: SCALE: 1" = 1500' VICINITY MAP LAFAYETTE MEADOWS SUBDIVISION N The Curry Engineering Group, PLLC NC License # P-0799 PO Box 2018 205 S. Fuquay Ave Fuquay-Varina, NC 27526 919.552.0849 (o) 919.880.9857 (m) Contact: Don Curry, PE don@curryeng.com Developer: HARNETT COUNTY, NORTH CAROLINA MAJOR SUBDIVISION - PRELIMINARY PLAN HARNETT COUNTY SITE GOVERNING AGENCIES: UTILITY AGENCIES: PLANNING/ZONING/LANDSCAPE HARNETT COUNTY PLANNING DEPT. 108 E. FRONT STREET LILLINGTON, NC 27546 910.893.7525 OPT. 4 CONTACT: MR. LANDON CHANDLER EROSION CONTROL STORMWATER WATER & SEWER HARNETT COUNTY PUBLIC UTILITIES DEPT. 700 McKINNEY PARKWAY LILLINTON, NC 27546 910.893.7575 CONTACT: MR. SHANE CUMMINGS NCDENR-DWQ SEWER NCDENR DIVISION OF WATER RESOURCES FAYETTEVILLE REGIONAL OFFICE 225 GREEN STREET SUITE 714 FAYETTEVILLE, NC 28301 910.433.3300 NCDENR-PUBLIC WATER SUPPLY NCDENR DIVISION OF WATER RESOURCES RALEIGH REGIONAL OFFICE 512 N. SALISBURY STREET RALEIGH, NC 27604 919.707.9100 ENGINEERING HARNETT COUNTY PUBLIC UTILITIES DEPT. 700 McKINNEY PARKWAY LILLINTON, NC 27546 910.893.7575 CONTACT: MR. SHANE CUMMINGS Land Owner: Bobby B. & Betty S. Matthews 4069 Chalybeate Springs Road Fuquay-Varina, NC 27526 Carolina Development Group 10136 Mizner Lane Raleigh, NC 27617 919-931-2300 (m) Contact: Mark Puryear mark@carolinadevgroup.com COVER SHEET C-00N.T.S DRAWING INDEX Sheet Number Sheet Title C-00 COVER SHEET C-01 CIVIL NOTES C-02 EXISTING CONDITIONS PLAN C-03 OVERALL SUBDIVISION LAYOUT CORNER LOT STANDARD LOT 10'25'25' 10'10' 20' 35'35' FRONTFRONT REARREARCORNERSIDESIDE SIDESCALE: 3 C-00 TYPICAL BUILDING SETBACKS NTS RESIDENTIAL RA-40 LC RD. 50' PROPOSED ROW 11' 2.5' 27' ROADWAY 11' 2%2% TIE TO EXISTING 2.5' 30" VALLEY CURB & GUTTER 11.5'11.5' TIE TO EXISTING 1" SF9.5A 1.5" S9.5B 5.5'5' SIDEWALK 1' 2% 30" VALLEY CURB & GUTTER 2% PAVEMENT SECTION PER NCDOT SUBDIVISION STANDARDS 100' PROPOSED ROW 2.5' 80' BC-BC SLOPES VARIES TIE TO EXISTING 30" VALLEY CURB & GUTTER 10'10' TIE TO EXISTING 1" SF9.5A 1.5" S9.5B 30" VALLEY CURB & GUTTER 75' EOP-EOP SLOPES VARIES SLOPES VARIES COMPACTED SUBGRADE COMPACTED SUBGRADE SCALE: 1 C-00 TYPICAL STREET SECTION NTS RESIDENTIAL STREET SCALE: 2 C-00 TYPICAL STREET SECTION NTS CUL-DE-SAC 2:1 MA X. 2:1 M A X . 2:1 M A X . 2:1 MAX . 2:1 M A X . 2:1 MAX . 2:1 MA X. 2:1 M A X . BAPTIST GR O V E R D . ( S R 1 4 2 7 ) NCDEQ DIVISION OF ENERGY, MINERAL & LAND RESOURCES RALEIGH REGIONAL OFFICE 512 N. SALISBURY STREET RALEIGH, NC 27604 919.807.6369 CONTACT: MR. ROBERT PATTERSON, PE NCDEQ DIVISION OF ENERGY, MINERAL & LAND RESOURCES FAYETTEVILLE REGIONAL OFFICE 225 GREEN STREET SUITE 714 FAYETTEVILLE, NC 28301 910.433.3300 E N G I NE ERI N G Curry 205 S. Fuquay Avenue Fuquay-Varina, NC 27526 (919) 552-0849 (919) 552-2043CURRY E NGINE E RSNOR TH CA R O L INAEST.1 0 NC LIC. NO. P-0799 T F Z:\PROJECTS FOLDER-ZEBULON\2018\2018-027 PURYEAR - BAPTIST GROVE - HARNETT CO\PLANS\PRELIM SUBDIVISION\SHEET FILES\C-00 COVER SHEET.DWGPLOTTED: 2/19/2019 4:13 PMPROFESSIONAL'S SEAL DATE: FILE NO. HORZ. SCALE: ORIG. SHEET SIZE: REVISIONS 24 x 36 STATUS CONSULTANT CLIENT PRELIMINARY SUBDIVISION LAFAYETTE MEADOWS SUBDIVISION SEPTEMBER 11, 2018 2018-027 FOR REVIEW ONLY NOT FOR CONSTRUCTION Carolina Development Group 10136 Mizner Lane Raleigh, NC 27617 919-931-2300 (m) Contact: Mark Puryear mark@carolinadevgroup.com PRELIMINARY DO NOT USE FOR CONSTRUCTION DRB REVISIONS #12018-11-061 DRB REVISIONS #22018-11-262 DRB REVISIONS #32019-01-163 DRB REVISIONS #42019-02-194 CHALYBEATE RD. (SR 1429)US - 401PAVEMENT SECTION PER NCDOT SUBDIVISION STANDARDS NCDOT NC DEPT. OF TRANSPORTATION DIV. 6, DISTRICT 2 600 SOUTHERN AVENUE FAYETTEVILLE, NC 28302 910.364.0601 CONTACT: MR. RICHIE HINES Soil Scientist: Hal Owen & Associates, Inc. PO Box 400 Lillington, NC 27546 910.893.8743 (o) Contact: Hal Owen halowen@earthlink.net 1 OWNER'S CONSENT FORM 1 2 C-01 E N GI NE ERI N G Curry 205 S. Fuquay Avenue Fuquay-Varina, NC 27526 (919) 552-0849 (919) 552-2043CURRY E NGIN E E RSNOR TH CA R O L INAEST.1 0 NC LIC. NO. P-0799 T F Z:\PROJECTS FOLDER-ZEBULON\2018\2018-027 PURYEAR - BAPTIST GROVE - HARNETT CO\PLANS\PRELIM SUBDIVISION\SHEET FILES\C-01 CIVIL NOTES.DWGPLOTTED: 2/19/2019 4:13 PMPROFESSIONAL'S SEAL DATE: FILE NO. HORZ. SCALE: ORIG. SHEET SIZE: REVISIONS 24 x 36 STATUS CONSULTANT CLIENT PRELIMINARY SUBDIVISION LAFAYETTE MEADOWS SUBDIVISION SEPTEMBER 11, 2018 2018-027 FOR REVIEW ONLY NOT FOR CONSTRUCTION Carolina Development Group 10136 Mizner Lane Raleigh, NC 27617 919-931-2300 (m) Contact: Mark Puryear mark@carolinadevgroup.com PRELIMINARY DO NOT USE FOR CONSTRUCTION DRB REVISIONS #12018-11-061 DRB REVISIONS #22018-11-262 DRB REVISIONS #32019-01-163 DRB REVISIONS #42019-02-194 CIVIL NOTES 1.BOUNDARY & TOPOGRAPHY INFORMATION AS SHOWN ON THIS PRELIMINARY SUBDIVISION PACKAGE IS FROM HARNETT COUNTY GIS DATA AND SHOULD BE CONSIDERED PRELIMINARY. A FIELD-SURVEY BOUNDARY & TOPOGRAPHIC SURVEY IS UNDERWAY AND WILL BE UTILIZED FOR CONSTRUCTION DRAWINGS. 2.ALL WORK, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE HARNETT COUNTY STANDARDS AND SPECIFICATIONS, LATEST EDITION. 3.ALL WORK, CONSTRUCTION AND MATERIALS WITHIN NCDOT RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH THE 2012 NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES. 4.ALL RIGHT OF WAYS SHALL BE PUBLIC. 5.THIS SITE IS NOT LOCATED IN A FLOOD HAZARD ZONE PER FEMA MAPS 37085C-0642 AND 37085C-0654 DATED XXX. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ZONE TRAFFIC CONTROL IN OR ADJACENT TO NCDOT RIGHT-OF-WAY. TRAFFIC CONTROL SHALL BE MAINTAINED AT ALL TIMES WITH PROPER SIGNAGE, SIGNALS, LIGHTING, FLAGMEN. ALL SIGNS, PAVEMENT MARKINGS AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION. 7.COPIES OF ALL PERMITS AND APPROVED PLANS MUST BE KEPT ON SITE IN A PERMIT BOX THAT IS CONSPICUOUSLY LOCATED AND EASILY ACCESSIBLE DURING CONSTRUCTION. THIS INCLUDES APPROVED CONSTRUCTION PLANS, APPROVED EROSION CONTROL PLANS, ENCROACHMENT AGREEMENTS, DRIVEWAY PERMITS, WATER/SEWER PERMITS, ETC. 8.LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE AND MUST BE FIELD VERIFIED. CONTACT THE NC ONE CALL CENTER AT LEAST 48 HOURS PRIOR TO DIGGING @ 1.800.632.4949. UNDERGROUND LINES SHOWN HEREON ARE APPROXIMATE OR AS REPORTED BY VARIOUS RESPONSIBLE PARTIES. THE SURVEYOR DOES NOT GUARANTEE THAT ANY UNDERGROUND STRUCTURES SUCH AS UTILITIES, TANKS AND PIPES ARE LOCATED HEREON. 9.THE CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OR FIRMS HAVING FACILITIES ON OR ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING OR CONNECTING TO SAID FACILITIES. 10.THE CONTRACTOR IS RESPONSIBLE FOR REPAIR OF ANY COUNTY OR NCDOT DAMAGED PROPERTY. THE CONTRACTOR SHALL REPAIR THE DAMAGED PROPERTY TO THE LATEST STANDARDS AND SPECIFICATIONS OF THE AGENCY HOLDING JURISDICTION AT NO COST TO THE OWNER. 11.ANY DAMAGE DONE TO PRIVATE PROPERTY OWNERS SIGNS, MAILBOX, DRIVEWAY CULVERTS, OR OTHER PROPERTY SHALL BE RESTORED TO ORIGINAL CONDITION. 12.CONTRACTOR IS RESPONSIBLE FOR FENCING AND SECURITY OF HIS LAYDOWN AND STORAGE AREA. 13.CONTRACTOR SHALL KEEP ALL ROADS FREE OF DIRT AND DEBRIS AT ALL TIMES. 14.CONTRACTOR SHALL PROTECT EXISTING PAVEMENTS AND UTILITIES FROM HEAVY EARTH MOVING EQUIPMENT. PROVIDE TRAFFIC CONTROL AND ADEQUATE PROTECTION METHODS AT ALL EQUIPMENT CROSSINGS. 15.ALL EXCAVATION IS UNCLASSIFIED AND SHALL INCLUDE ALL MATERIALS ENCOUNTERED. 16.ALL STRUCTURAL FILL MATERIAL SHALL BE FREE OF ALL STICKS, ROCKS, AND CLUMPS OF MUD. ALL ROCKS GREATER THAN 3" DURING EXCAVATION SHALL BE REMOVED. 17.UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE DISPOSED OF OFF-SITE BY THE CONTRACTOR IN AN APPROVED, LEGAL DISPOSAL SITE. 18.CONCRETE SIDEWALKS THAT ARE TO BE REMOVED SHALL BE CUT BACK TO NEAREST EXPANSION OR CONTROL JOINT AND REPLACED WITH 4-INCH CONCRETE SIDEWALK FINISHED TO MATCH EXISTING SIDEWALKS. 19.CONTRACTOR TO COORDINATE WITH HARNETT COUNTY FOR TEMPORARY WATER NEEDED DURING CONSTRUCTION. IF PERMITTED TO CONNECT TO EXISTING FIRE HYDRANT, A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTER WILL BE REQUIRED. 20.THE TRANSITION OF PROPOSED ROADWAY TO EXISTING ROADWAY SHALL BE DONE WITH A MINIMUM 8-FT TRANSITION WHERE THE EXISTING PAVEMENT IS MILLED TO A MINIMUM DEPTH OF 1-1/2" AND OVERLAID. 21.ALL PAVEMENT SAW CUTS SHALL BE NEAT, STRAIGHT AND FULL DEPTH. 22.ALL RIP-RAP IS TO BE INSTALLED WITH NON-WOVEN FILTER FABRIC BENEATH (MIRAFI 140 N OR APPROVED EQUAL). 23.ALL EXCESS TOPSOIL AND UNCLASSIFIED EXCAVATION IS TO BE HAULED OFF-SITE, UNLESS OTHERWISE DIRECTED BY THE OWNER TO AN APPROVED NCDENR LOCATION. 24.ALL SITE CONSTRUCTION MUST BE INSPECTED BY THE GEOTECHNICAL ENGINEER AT THE FOLLOWING STAGES: A.COMPLETION OF GRADING SUBGRADE PRIOR TO PLACING STONE BASE. B. COMPLETION OF STONE PLACEMENT PRIOR TO PAVING. C.FINAL INSPECTION WHEN ALL WORK IS COMPLETE. 25.PRIOR TO PLACING CABC STONE BASE, THE CONTRACTOR SHOULD NOTIFY THE GEOTECHNICAL ENGINEER TO INSPECT THE PROOF ROLL OF THE SUBGRADE. ANY STONE PLACED WITHOUT PRIOR APPROVAL WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SUBJECT TO RE-CONSTRUCTION IF SUBGRADE DOES NOT MEET TOWN AND NCDOT STANDARDS & SPECIFICATION 26.ALL UTILITY SERVICES, (POWER, TELEPHONE, CABLE, ETC.) ARE PROPOSED TO BE UNDERGROUND. DO NOT SEED OR MULCH DISTURBED AREAS UNTIL ALL UNDERGROUND UTILITIES HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE PRIVATE UTILITY SERVICE COMPANIES FOR ANY REQUIRED CONDUITS OR POINT OF CONTACT CONDITIONS. 27.ALL PUBLIC UTILITIES THAT REQUIRE AN ENGINEERING CERTIFICATION MUST BE INSPECTED BY A PROFESSIONAL ENGINEER ON A PERIODIC BASIS. THE CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER WHEN INSTALLING UTILITIES FOR PERIODIC INSPECTIONS. THE CONTRACTOR SHALL CONTACT THE PROJECT ENGINEER AT THE TIME OF PRESSURE TESTING AND WATER LINE DISINFECTION. THE CONTRACTOR SHALL SUPPLY THE PROJECT ENGINEER PRESSURE TEST RESULTS. 28.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD CONDITIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATION OF ALL EXISTING UTILITIES BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF TRENCHING. IF THE CLEARANCES ARE LESS THAN SPECIFIED ON THE PLANS OR 12 INCHES, WHICH EVER IS LESS, CONTACT THE PROJECT ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 29.THE CONTRACTOR SHALL INCLUDE IN HIS CONTRACT PRICE THE REMOVAL AND DISPOSAL OF ANY EXCESS TOPSOIL HE DETERMINES IS NOT REQUIRED TO PERFORM THE FINAL GRADING AND LANDSCAPING OPERATION. 30.THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE DAILY RECORD KEEPING OF THE AS-BUILT CONDITION OF ALL OF THE UNDERGROUND UTILITIES, CONSTRUCTION STAKEOUT ASSOCIATED WITH THE PROJECT. PREPARATION OF THE NECESSARY/REQUIRED AS-BUILT PLANS TO BE SUBMITTED TO HARNETT COUNTY AND/OR ALL OTHER INFORMATION REQUIRED IN CONNECTION WITH RELEASE OF BONDS. 31.THE CONTRACTOR SHALL INCLUDE IN THE PRICE, ANY AND ALL COSTS ASSOCIATED WITH PROVIDING A PROFESSIONAL ENGINEER ON SITE IF REQUIRED, DURING THE CONSTRUCTION OF THE STORMWATER MANAGEMENT FACILITIES, UNDERGROUND UTILITIES, ETC. AS REQUIRED FOR AS-BUILT CERTIFICATION. 32.THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THE DRAWINGS. NCDOT, HARNETT COUNTY & CURRY ENGINEERING ACCEPT NO RESPONSIBILITY FOR THE DESIGN TO INSTALL SAID ITEMS. 33.TESTING BY CONTRACTOR: CONTRACTOR SHALL EMPLOY AT HIS EXPENSE AN OUTSIDE INDEPENDENT SOIL TESTING SERVICE (APPROVED BY THE OWNER) TO PERFORM SOIL TESTING AND INSPECTION SERVICE FOR QUALITY CONTROL TESTING DURING EARTHWORK OPERATIONS. COPIES OF RESULTS OF TESTS SHALL BE SUBMITTED BY THE TESTING SERVICE DIRECTLY TO THE CONTRACTOR, THE OWNER, AND THE APPLICABLE APPROVING AGENCY. --THE TESTING SERVICE WILL CLASSIFY PROPOSED ON-SITE AND BORROW SOILS TO VERIFY THAT SOILS COMPLY WITH SPECIFIED REQUIREMENTS AND TO PERFORM REQUIRED FIELD AND LABORATORY TESTING. (MINIMUM REQUIRED SOIL BEARING CAPACITY IS NOTED ON THE STRUCTURAL DRAWINGS). --IN PAVED AND BUILDING SLAB AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD DENSITY TEST FOR EACH 2000 SQUARE FEET OF FILL IN EACH COMPACTED FILL LAYER. IF A TEST SHOULD FAIL TO MEET REQUIRED DENSITY, THE CONTRACTOR SHALL RE-COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM ADDITIONAL TESTS AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE REQUIRED COMPACTION. --IN FOUNDATION WALL AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD DENSITY TEST FOR EACH 100 FEET OR LESS OF WALL LENGTH OF FILL IN EACH COMPACTED FILL LAYER, WITH NO LESS THAN TWO TESTS ALONG A WALL FACE. IF A TEST SHOULD FAIL TO MEET REQUIRED DENSITY, THE CONTRACTOR SHALL RE-COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM ADDITIONAL TESTS AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE REQUIRED COMPACTION. 34.COMPACTION: COMPACT EACH LAYER OF BACKFILL AND FILL SOIL MATERIALS AND THE TOP 12" OF SUBGRADE IN CUT AREAS TO 100% OF MAXIMUM DENSITY IN ACCORDANCE WITH AASHTO T99 FOR STRUCTURES, SLABS, AND PAVEMENTS AND 95% OF MAXIMUM DENSITY FOR EMBANKMENTS OR UNPAVED AREAS. MAX LIFT THICKNESS FOR FILL AREAS IS 8 INCHES. 35.DISTURBED AREA IS IN EXCESS OF 1 ACRE AND FORMAL SEDIMENTATION & EROSION CONTROL PLAN APPROVAL IS REQUIRED AS A CONDITION OF CONSTRUCTION PLAN APPROVAL. A COPY OF THE APPROVED EROSION CONTROL PLAN MUST BE KEPT ON SITE AT ALL TIMES. THE APPROVED SEDIMENTATION & EROSION CONTROL PLAN SHOULD BE REGARDED AS MINIMUM REQUIREMENTS; ADDITIONAL MEASURES SHALL BE PUT IN PLACE AS NEEDED TO ENSURE THAT NO SEDIMENT IS RELEASED FROM THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR PICKING UP AND PAYING FOR GRADING PERMIT ISSUED BY NCDENR DIVISION OF ENERGY, MINERALS AND LAND QUALITY. 36.DESIGN/FIELD CONDITIONS QUITE EASILY MAY VARY FROM THAT REPRESENTED IN THE INITIAL SOILS REPORT AND/OR TOPOGRAPHICAL REPORT. ISOLATED AREAS MAY SHOW UP WEAK AND ADVERSE SOILS OR GROUNDWATER CONDITIONS MAY BE DISCOVERED THAT WERE NOT REVEALED DURING THE INITIAL SOILS INVESTIGATION. THEREFORE, THE OWNER/CLIENT IS TO BE AWARE THAT CURRY ENGINEERING GROUP, PLLC WILL NOT AND CANNOT BE HELD RESPONSIBLE FOR ANY FAILURES TO EITHER A STREET OR PARKING LOT PAVEMENT DESIGN UNLESS WE CAN BE FULLY AND TOTALLY INVOLVED IN THE CONSTRUCTION PROCESS WHICH MAY INCLUDE, BUT MAY NOT NECESSARILY BE LIMITED TO, TESTING SUBGRADE AND BASE DENSITY, ENGAGING THE GEOTECHNICAL ENGINEER FOR THE EVALUATION OF THE SUBGRADE AND FOR THE OBSERVATION OF PROOF ROLLING SUBGRADE AND BASE AT VARIOUS STEPS OF CONSTRUCTION, OPPORTUNITY FOR THE DESIGN ENGINEER TO CALL IN A GEOTECHNICAL ENGINEER FOR CONSULTATION AND ADVICE, ETC. - STEPS WHICH TAKEN ALTOGETHER WITH THE INITIAL DESIGN SHOWN ON THE PLANS, CONSTITUTE THE COMPLETE DESIGN OF THE ROAD, STREET OF PARKING AREA (PRIVATE OR PUBLIC). THE DESIGN ENGINEER MUST BE GIVEN THE FULL LATITUDE AND OPPORTUNITY TO COMPLETE THE DESIGN BY FULLY PARTICIPATING IN THE CONSTRUCTION PROCESS. PLAN DESIGN IS A SMALL PORTION OF THE DESIGN AND CANNOT BE SEPARATED FROM THE CONSTRUCTION PROCESS IF THE OWNER'S/CLIENT'S DESIRE IS TO HAVE THE DESIGN ENGINEER STAND BEHIND THE COMPLETED DESIGNED PROJECT. GENERAL CONSTRUCTION NOTES: P PROPERTY LINE L L CENTERLINE DIAMETER OR ROUND C AND & -- C -- -- A -- -- B -- -- D -- -- E -- -- F -- -- G -- -- H -- -- I -- -- L -- ** ALL SYMBOLS & ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE USED IN THIS DRAWING PACKAGE ** IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION GENERAL ABBREVIATIONS: ABC AGGREGATE BASE ASPH ASPHALT AVE AVENUE BLVD BOULEVARD BLDG BUILDING BOC BACK OF CURB BW BOTTOM OF WALL CB CATCH BASIN CI CURB INLET CIP CAST IRON PIPE CLS CLASS CJ CONTROL JOINT CO CLEANOUT CONC CONCRETE DI DROP INLET DIA DIAMETER DIP DUCTILE IRON PIPE DOM DOMESTIC DR DRIVE (XX) EXISTING ELEVATION E EAST, EASTING EL ELEVATION EJ EXPANSION JOINT EOP EDGE OF PAVEMENT EX EXISTING EVAP EVAPORATIVE FDC FIRE DEPARTMENT CONNECTION FES FLARED END SECTION FFE FINISHED FLOOR ELEVATION FG FINISHED GRADE FHA FIRE HYDRANT ASSEMBLY FL FLOW LINE FT FOOT OR FEET G GAS GALV GALVANIZED GB GRADE BREAK GE GENERAL ELECTRIC GR GRADE HDPE HIGH DENSITY POLYETHYLENE HORIZ HORIZONTAL HOV HIGH OCCUPANCY VEHICLE HP HIGH POINT IAW IN ACCORDANCE WITH I.H.INTERSTATE HIGHWAY INV INVERT LEN LENGTH LEV LOW EMISSION VEHICLE LF LINEAR FEET LP LOW POINT www.ncocc.org BEFORE YOU DIG, CALL NORTH CAROLINA ONE CALL CENTER -- M -- -- N -- -- O -- -- P -- -- R -- -- S -- -- T -- -- U -- -- V -- -- W -- -- Y -- MAX MAXIMUM MH MANHOLE MIN MINIMUM N NORTH, NORTHING NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES NCDOT NORTH CAROLINA DEPARTMENT OF TRANSPORTATION NTS NOT TO SCALE OH OVERHEAD OCB OFF-SET CATCH BASIN PCC PORTLAND CEMENT CONCRETE PE POLYETHYLENE PKWY PARKWAY POC POINT OF CONNECTION PVC POLYVINYL CHLORIDE R RADIUS RCP REINFORCED CONCRETE PIPE R.O.W. RIGHT OF WAY RPDA REDUCED PRESSURE DETECTOR ASSEMBLY RPZ REDUCED PRESSURE ZONE S SOUTH SD STORM DRAIN SDMH STORM DRAIN MANHOLE SDE SIGHT DISTANCE EASEMENT SSMH SANITARY SEWER MANHOLE SS SANITARY SEWER STA STATION STD STANDARD ST.STL STAINLESS STEEL SWPPP STORMWATER POLLUTION PREVENTION PLAN TB TOP OF BARRIER TC/TOC TOP OF CURB TD TEMPORARY DIVERSION TH TEST HEADER TOP TOP OF PIPE TP TOP OF PAD TYP TYPICAL TW TOP OF WALL UG UNDERGROUND VEG VEGETATED VERT VERTICAL W WEST W/ WITH W/O WITHOUT YI YARD INLET IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION IDENTIFIER DESCRIPTION WTLDWTLDWTLDWTLDWTLDWT L D WTLD WTLD WTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDBOBBY B MATTHEWS & BETTY S MATTHEWS D.B. 995E, PG. 0366 PIN: 0653-29-8668.00 ZONING: RA-40 AREA: 34.50 AC KELLY O MCRAE PIN: 0653-19-7851.000 ZONING: RA-40 NINA L BRAMMER PIN: 0653-29-6110.000 ZONING: RA-40 BEN & CAROL MURRAY PIN: 0653-29-4076.000 ZONING: RA-40 CATHY TOLAR PIN: 0653-39-5615.000 ZONING: RA-40 SUE SEARS & JOSEPH F ANDREWS JR TIC PIN: 0654-51-5454.000 ZONING: RA-40 BROWN STREET ASSOCIATES, LLC PIN: 0654-41-2622.000 ZONING: IND SUE SEARS & JOSEPH F ANDREWS JR TIC PIN: 0654-30-4801.000 ZONING: RA-40 W W W W W W W W W W W W W W W W W W W W W W W W W W C-02 E N GI NE ERI N G Curry 205 S. Fuquay Avenue Fuquay-Varina, NC 27526 (919) 552-0849 (919) 552-2043CURRY E NGIN E E RSNOR TH CA R O L INAEST.1 0 NC LIC. NO. P-0799 T F Z:\PROJECTS FOLDER-ZEBULON\2018\2018-027 PURYEAR - BAPTIST GROVE - HARNETT CO\PLANS\PRELIM SUBDIVISION\SHEET FILES\C-02 EXISTING CONDITIONS PLAN.DWGPLOTTED: 2/19/2019 4:13 PMPROFESSIONAL'S SEAL DATE: FILE NO. HORZ. SCALE: ORIG. SHEET SIZE: REVISIONS 24 x 36 STATUS CONSULTANT CLIENT PRELIMINARY SUBDIVISION LAFAYETTE MEADOWS SUBDIVISION SEPTEMBER 11, 2018 2018-027 FOR REVIEW ONLY NOT FOR CONSTRUCTION Carolina Development Group 10136 Mizner Lane Raleigh, NC 27617 919-931-2300 (m) Contact: Mark Puryear mark@carolinadevgroup.com PRELIMINARY DO NOT USE FOR CONSTRUCTION DRB REVISIONS #12018-11-061 DRB REVISIONS #22018-11-262 DRB REVISIONS #32019-01-163 DRB REVISIONS #42019-02-194 EXISTING CONDITIONS PLAN SCALE: 1" = 1500' VICINITY MAP N SITE BAPTIST GR O V E R D . ( S R 1 4 2 7 )US - 401GENERAL NOTES: 1.THIS PLAN IS NOT INTENDED FOR PLATING OR RECORDATION. 2.THE INTENT OF THIS PLAN IS TO ILLUSTRATE THE EXISTING FEATURES, STRUCTURES AND TOPOGRAPHY OF THE PROPERTY. THE INFORMATION SHOWN ON THIS PLAN WAS PROVIDED AND DEVELOPED BY OTHERS. CURRY ENGINEERING DOES NOT GUARANTEE THE ACCURACY OF THE INFORMATION, THUS IT HAS NOT BEEN SEALED. THE BOUNDARY & ENVIRONMENTAL INFORMATION SHOWN REPRESENTS A SERIES OF FIELD SURVEYS. 3.TOPOGRAPHY SHOWN ON THIS PLAN IS PER NC ONE MAP GIS. 4.EXISTING WATER LINES SHOWN ON THIS PLAN FROM HARNETT COUNTY GIS. 5.THE ENGINEER UNDERSTANDS THE PRELIMINARY INFORMATION PROVIDED TO MEET THE FOLLOWING CRITERIA: ·THE PROPERTY SHOWN HEREON IS SUBJECT TO ALL EASEMENTS OF RECORD AFFECTING SAME. PROPERTY BOUNDARY SHOWN BASED PER MAPS AND DEEDS OF RECORD ONLY. ·NO TITLE SEARCH HAS BEEN PERFORMED BY THIS FIRM DURING THE COURSE OF THIS SURVEY. ·THIS INFORMATION DOES NOT CERTIFY TO THE EXISTENCE OR NON-EXISTENCE OF ANY UNDER GROUND UTILITIES THAT MAY OR MAY NOT BE PRESENT ON THIS SITE. 6.WETLANDS & SOILS INFORMATION SHOWN ON PLAN BASED ON PRELIMINARY STREAM AND SOILS INVESTIGATION CONDUCTED BY HAL OWEN & ASSOCIATES ON FEBRUARY 26, 2018. DELINEATIONS HAVE NOT BEEN APPROVED BY NCDENR AND USACE. 7.FLOOD HAZARD SOILS ARE NOT ANTICIPATED ON THIS PROPERTY PER HARNETT COUNTY GIS. N 100'200' SCALE IN FEET 50'100' SCALE: 1 IN = 100 FT SCALE IN FEET HORIZONTAL 0 30' STREAM BUFFER 30' STREAM BUFFER SUITABLE SOIL LINE WETLAND LINE SUITABLE SOIL LINE SUITABLE SOIL LINE WETLAND LINE WETLAND LINE 30' POND BUFFER 30' STREAM BUFFER 30' STREAM BUFFER EXISTING 6" WATER MAIN (LOCATION TO BE VERIFIED) EXISTING EOP BAPTIST GROVE RD. - SR 1427 ( 60' PUBLIC R/W )1 1 CHALYBEATE RD . (SR 1429) WTLDWTLDWTLDWTLDWTLDWTLDWTLDWT L D WTLD WTLD WTLD WTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDWTLDKELLY O MCRAE PIN: 0653-19-7851.000 ZONING: RA-40 NINA L BRAMMER PIN: 0653-29-6110.000 ZONING: RA-40 BEN & CAROL MURRAY PIN: 0653-29-4076.000 ZONING: RA-40 CATHY TOLAR PIN: 0653-39-5615.000 ZONING: RA-40 SUE SEARS & JOSEPH F ANDREWS JR TIC PIN: 0654-51-5454.000 ZONING: RA-40 BROWN STREET ASSOCIATES, LLC PIN: 0654-41-2622.000 ZONING: IND W W W W W W W W W W W W W W W W W 23 22 18 21 20 19 26 27 24 25 3 2 1 13 6 14 LOT 23855 SQFT. 0.55 AC. LOT 30912 SQFT. 0.71 AC.LOT 31960 SQFT. 0.73 AC. LOT 26919 SQFT. 0.62 AC. LOT 21280 SQFT. 0.49 AC. LOT 21281 SQFT. 0.49 AC. LOT 21211 SQFT. 0.49 AC. LOT 21279 SQFT. 0.49 AC. LOT 21008 SQFT. 0.48 AC. LOT 21007 SQFT. 0.48 AC. LOT 21007 SQFT. 0.48 AC. LOT 31308 SQFT. 0.72 AC. LOT 49447 SQFT. 1.14 AC. LOT 30192 SQFT. 0.69 AC. LOT 23376 SQFT. 0.54 AC. LOT 21651 SQFT. 0.50 AC.276'110'273'110' 115'271'115' 96'265'38'224'16' 11' 50'4' 6' 51 ' 70'32' 6' 35' 47'322'11' 102'385'5' 70'51'270'198'214'60'223'145'200'40'105'200'105'105'200'105'105'200'105'115'185'115'185'115'90'25'185'115'115'185' 18 8 '124'69'157'40' 106' 175'51'21 '33'12'159' 83'238 '50'250'240'50' 80'158'185' 50 '116'91'150'14'33'21'40'187'276'361'12' 106'359'182' 4 LOT 24787 SQFT. 0.57 AC. 15' 47' 5 LOT 32009 SQFT. 0.73 AC.261'281'9'16'15 LOT 62649 SQFT. 1.44 AC. LOT 33084 SQFT. 0.76 AC. LOT 56271 SQFT. 1.29 AC. LOT 29787 SQFT. 0.68 AC.LOT 31394 SQFT. 0.72 AC.LOT 29624 SQFT. 0.68 AC. LOT 32619 SQFT. 0.75 AC. LOT 39416 SQFT. 0.90 AC. LOT 31043 SQFT. 0.71 AC. 12 1716 11 10 9 8 7 87'20'100' 43' 74' 34' 110'34' 59' 67' 71' 79'WWWW W W W W W W W WWWWW26'65'78' 26' 65'9' 157' 1 5 ' 109'15'62'134'WCBUW WCBU ROADWAY CENTER LINE RIGHT OF WAY LINE LOT LINE SETBACK LINE VALLEY CURB & GUTTER STANDARD CURB & GUTTER WCR WHEELCHAIR RAMP SIGN STREET LIGHT CLUSTER MAILBOX UNIT UTILITY/STORM EASEMENT OPEN SPACE CONCRETE SIDEWALK ASPHALT PAVEMENT W BLOW OFF VALVE THRUST (REACTION) BLOCKING TEE GATE VALVE FIRE HYDRANT ASSEMBLY WATER LINE C-03 E N GI NE ERI N G Curry 205 S. Fuquay Avenue Fuquay-Varina, NC 27526 (919) 552-0849 (919) 552-2043CURRY E NGIN E E RSNOR TH CA R O L INAEST.1 0 NC LIC. NO. P-0799 T F Z:\PROJECTS FOLDER-ZEBULON\2018\2018-027 PURYEAR - BAPTIST GROVE - HARNETT CO\PLANS\PRELIM SUBDIVISION\SHEET FILES\C-03 OVERALL SUBDIVISION LAYOUT.DWGPLOTTED: 2/19/2019 4:14 PMPROFESSIONAL'S SEAL DATE: FILE NO. HORZ. SCALE: ORIG. SHEET SIZE: REVISIONS 24 x 36 STATUS CONSULTANT CLIENT PRELIMINARY SUBDIVISION LAFAYETTE MEADOWS SUBDIVISION SEPTEMBER 11, 2018 2018-027 FOR REVIEW ONLY NOT FOR CONSTRUCTION Carolina Development Group 10136 Mizner Lane Raleigh, NC 27617 919-931-2300 (m) Contact: Mark Puryear mark@carolinadevgroup.com PRELIMINARY DO NOT USE FOR CONSTRUCTION DRB REVISIONS #12018-11-061 DRB REVISIONS #22018-11-262 DRB REVISIONS #32019-01-163 DRB REVISIONS #42019-02-194 OVERALL SUBDIVISION LAYOUT N SCALE IN FEETSCALE IN FEET HORIZONTAL 80'160'040'80' SCALE: 1 IN = 80 FT GENERAL NOTES: 1.ALL CONSTRUCTION SHALL BE PER HARNETT COUNTY STANDARDS AND SPECIFICATIONS. 2.ALL DIMENSIONS ARE IN FEET AND TO BACK OF CURB UNLESS OTHERWISE NOTED. 3.ALL SITE ELEMENTS ARE PERPENDICULAR TO EACH OTHER UNLESS OTHERWISE NOTED. 4.CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, RIGHT-OF-WAYS AND UTILITIES, PUBLIC OR PRIVATE, BEFORE WORKING IN THESE AREAS. 5.PROTECT ALL PROPERTY MONUMENTS AND PINS. MONUMENTS AND PINS THAT WILL BE DISTURBED DURING CONSTRUCTION SHALL BE REFERENCED AND REPLACED BY A LICENSED LAND SURVEYOR AT THE COST OF THE CONTRACTOR. 6.CONTRACTOR SHALL MAINTAIN THE SITE IN SUCH A MANNER THAT WORKMEN AND THE PUBLIC WILL BE PROTECTED FROM INJURY AND ADJOINING PROPERTY PROTECTED FROM DAMAGE 7.CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT LEAST ONCE A WEEK DURING CONSTRUCTION. 8.CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL DUE TO CONSTRUCTION OPERATIONS. ALL STREET SURFACES, UTILITY POLES, CULVERTS, DITCHES, CURB AND GUTTER OR OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROPRIATE SPECIFICATIONS. 9.IF DEPARTURES FROM THE DRAWINGS OR SPECIFICATIONS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREOF SHALL BE SUBMITTED IN WRITING TO THE FACILITY DESIGNER FOR REVIEW. NO DEPARTURES FROM THE CONTRACT DOCUMENTS WILL BE ALLOWED WITHOUT APPROVAL BY THE FACILITY DESIGNER. 10.ANY AND ALL QUANTITIES SHOWN OR IMPLIED ON THE PLANS ARE FOR ESTIMATION PURPOSES ONLY. 11.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. 12.ENTRY SIGNS SHALL BE LOCATED IN A DEDICATED EASEMENT. SIGN MUST REMAIN OUT OF SIGHT TRIANGLES AS SHOWN ON PLANS. ENTRY SIGNS WILL REQUIRE A SEPARATE SIGN PERMIT. 13.ALL ASPHALT EDGES SHALL BE SAW CUT TO PROVIDE A GOOD LONGITUDINAL JOINT. MILL 1.5 FEET @ 1.5 INCHES DEEP MINIMUM TO PROVIDE A LONGITUDINAL LAP JOIN FOR FINAL SURFACE LAYER. NO MILLING SHALL BE LEFT FOR A PERIOD OF TIME GREATER THAN 48 HOURS BEFORE A STREET IS TO BE PAVED OR RESURFACED. 14.COMMON OPEN SPACE SHALL BE OWNED & MAINTAINED BY HOMEOWNERS' ASSOCIATION. 15.ANY SPECIALITY STREET SIGNS INCLUDING POSTS SHALL BE SUBMITTED TO THE HARNETT COUNTY FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 16.ALL PUBLIC AND PRIVATE EASEMENTS SHALL BE RECORDED AS PART OF THE FINAL PLAT OF THE SUBDIVISION. EASEMENTS BASED OF CENTER OF UTILITY OR PIPE SHALL BE PER AS-BUILT LOCATIONS. 17.AREAS OF PARENT PARCEL THAT ARE NOT SUBDIVIDED TO CREATE SINGLE FAMILY RESIDENTIAL LOTS ARE TO REMAIN AS ONE PARCEL TO BE OWNED AND MAINTAINED BY THE HOME OWNERS' ASSOCIATION OF THE NEIGHBORHOOD. 18.ALL OPEN SPACE AREAS INCLUDING WALKING TRAILS WILL BE OPEN TO THE PUBLIC. COMMUNITY CENTER WILL BE RESTRICTED TO THOSE WHO LIVE IN THE NEIGHBORHOOD. 19.MAINTENANCE FOR COMMUNITY CENTER, OPEN SPACE, & WALKING TRAILS SHALL BE THE RESPONSIBILITY OF THE HOA. 20.ALL UTILITY WORK WITHIN THE PUBLIC RIGHT OF WAY OR PUBLIC EASEMENTS SHALL BE TO THE LATEST EDITION OF THE HARNETT COUNTY DEPT. OF PUBLIC UTILITIES WATER & SEWER ORDINANCE AND THE UTILITY MASTER PLAN. 21.ALL WATER MAINS SHALL BE PUBLIC UTILITIES. 22.CONTRACTOR SHALL CONTACT HARNETT COUNTY UTILITIES PRIOR TO MAKING CONNECTION TO ANY COUNTY OWNED INFRASTRUCTURE. 23.CONTRACTOR CANNOT TAP WATER MAINS WITHOUT AN APPROVED WATER EXTENSION PERMIT ISSUED BY NCDENR - PUBLIC WATER SUPPLY. 24.WATER MAINS SHALL BE CLASS 150 C900 PVC I.A.W. AWWA C900 OR THICKNESS CLASS 50 DIP PUSH ON JOINTS I.A.W. AWWA C151 WHERE NOTED.DUCTILE IRON PIPE WATER MAINS SHALL BE CLASS 350 DIP I.A.W. AWWA C-151 WITH PUSH ON JOINTS I.A.W. AWWA C-111. DIP SHALL BE CEMENT-MORTAR LINED AND SEALED WITH BITUMINOUS MATERIAL I.A.W. AWWA C-104. ALL DIP BURIED PIPE SHALL HAVE AN BITUMINOUS EXTERIOR COATING I.A.W. AWWA C-151. MINIMUM BURIAL DEPTH FOR WATER MAIN IS 36 INCHES BELOW FINISHED GRADE. ALL FITTINGS SHALL BE MECHANICAL JOINTS I.A.W. AWWA C-111. 25.ALL WATER SERVICES TO LOTS SHALL BE 3/4" BLUE POLY TUBING W/TRACER WIRE. MINIMUM BURIAL DEPTH FOR WATER SERVICES IS 24 INCHES. 26.WHEN A NON-GRAVITY UTILITY MEETS A GRAVITY UTILITY, THE NON-GRAVITY UTILITY MUST BE ADJUSTED TO MEET SEPARATION REQUIREMENTS. 27.ALL NON-METALLIC PIPING MUST BE INSTALLED WITH TRACER WIRE PER HARNETT COUNTY STANDARDS. 28.PRIVATE UTILITIES (TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THOSE UTILITIES WHEN INSTALLING PUBLIC UTILITIES. 29.ELECTRICAL TRANSFORMERS SHALL NOT BE LOCATED WITHIN REQUIRED LANDSCAPED BUFFERS. 30.ALL ELECTRICAL THROUGHOUT THE SUBDIVISION SHALL BE UNDERGROUND. 31.REFER TO C-01 FOR HARNETT COUNTY PUBLIC UTILITIES REQUIRED NOTES. 32.THIS PROJECT IS IN THE HQW AND WS-IV-PA NC WATER SUPPLY WATERSHED AND AS SUCH, A STORMWATER PERMIT FROM NCDEQ IS REQUIRED. THE PROPOSED LAYOUT IS LESS THAN 12% IMPERVIOUS, THEREFORE A LOW-DENSITY STORMWATER PERMIT IS ANTICIPATED. 33.THIS DEVELOPMENT IS WITHIN 1 MILE OF A VOLUNTARY AGRICULTURAL DISTRICT. 34.THERE SHALL BE NO UNPERMITTED DISTURBANCE IN THE EXISTING WETLANDS. 35.NOTE THAT BUILDINGS WITHIN 10% OF THE REQUIRED SETBACK ARE REQUIRED TO PROVIDE FOUNDATION SURVEYS. 36.THIS SUBDIVISION WAS DESIGNED USING THE "COMPATIBILITY DESIGN CONCEPT." 37.STREET TREES SHALL BE INSTALLED AT A RATE OF 1/50 LF OF ROADWAY, MIN. 2" CALIPER AND 6' IN HEIGHT, MATURE HEIGHT OF 25'-35', AND BETWEEN 5' AND 10' OUTSIDE THE RIGHT-OF-WAY. 38.ALL UTILITIES, INCLUDING FIRE HYDRANTS, INSTALLED OUTSIDE OF THE PROPOSED ROW MUST BE IN A PUBLIC UTILITY EASEMENT. LEGEND: 75' "PRIME VIEWS AND VISTAS" BUFFER FIRE HYDRANT ASSEMBLY (FHA) EXIST. 6" PUBLIC WATER MAIN (LOCATION & MATERIAL TO BE CONFIRMED) BUILDING SETBACK (TYP.) SUITABLE SOILS FOR SEPTIC (MIN. 10,000 SF PER LOT) 6" PVC SDR-21 WATER LINE 30" VALLEY CURB 5' CONC. SIDEWALK 6" TEE & VALVES (3) BLOW OFF VALVE ASSEMBLY (BOA) CBU MAILBOX KIOSK SUITABLE SOIL LINE BLOW OFF VALVE ASSEMBLY (BOA) FIRE TRUCK TEMPORARY TURN AROUND PRELIM. WETLAND LINE (TO BE CONFIRMED) 30' POND BUFFER 30' STREAM BUFFER (TO BE CONFIRMED)LONG MEADOW LANE (1436')OLD MAPLE CT. (326')SITE INFORMATION ZONING: COUNTY: LOCATION: PARENT PIN: DB/PG: ACREAGE: HARNETT LAND CLASS:EMU RIGHT OF WAY & OTHER AREAS: RIGHT OF WAY DEDICATION: NATURAL WETLANDS: STREAM BUFFER:3.79 AC 9.84 AC 2.13 AC 34.50 AC 995E / 0366 0653-29-8668.000 LOT ACREAGE: TOTAL NUMBER PROPOSED LOTS: PROPOSED DENSITY: MINIMUM ALLOWED LOT SIZE: MINIMUM PROPOSED LOT SIZE: MAXIMUM PROPOSED LOT SIZE: AVERAGE PROPOSED LOT SIZE:30,384 SF 65,195 SF 21,007 SF 21,000 SF 0.78 DU/AC 27 SIDE YARD: FRONT YARD:35' 10' REAR YARD:25' MINIMUM BUILDING SETBACKS: CORNER YARD:20' MINIMUM ALLOWABLE LOT WIDTH:100' 100' NUMBER OF PHASES:1 IMPERVIOUS AREAS: ROADWAYS / PARKING:1.20 AC SIDEWALKS: LOTS (4,250 SF/LOT): TOTAL ON-SITE IMPERVIOUS AREA: TOTAL ON-SITE IMPERVIOUS PERCENT: UTILITY DEMANDS WATER USAGE: 0.19 AC 2.48 AC 3.87 AC 11.7% 9,720 GPD OPEN SPACE BREAKDOWN: 34.50 ac REQUIRED OPEN SPACE (20%):6.9 ac OPEN SPACE PROVIDED:13.1 ac (38%) PROPERTY BOUNDARY: 3 BED X 120 GPD/BED X 27 UNITS RA-40 BAPTIST GROVE RD. FUQUAY-VARINA, NC 27526 MINIMUM PROPOSED LOT WIDTH @ FRONT BUILDING SETBACK: 6"X6" TS&V OPEN SPACE: 11.8 AC OPEN SPACE: 1.3 AC 1 BAPTIST GROVE RD. - SR 1427 ( 60' PUBLIC R/W ) 12' OPEN SPACE ACCESS ESMT. 1 50' PUBLIC & UTILITY R/W 1 20' PRIVATE STORM DRAINAGE ESMT. 1 20' PRIVATE STORM DRAINAGE ESMT. 1 1 SIGN ESMT. 1 1 1 STREET LIGHTING - TYPICAL MAXIMUM SPACING=300', MIN. 7,000 LUMENS 1 STREET TREE REQUIREMENT: 1/50 LF OF ROADWAY = 29 TREES STREET TREE REQUIREMENT: 1/50 LF OF ROADWAY = 7 TREES (NOT TO SCALE) WAX MYRTLE (MYRICA CERIFERA) 24" HIGH @ PLANTING WILLOW OAK (QUERCUS PHELLOS) 2" CALIPER, 6' HIGH @ PLANTING STREETYARD BUFFER PLANTING 15' 50' MAX 7' 100' MIN. (WITHIN 75' PRIME VIEWS & VISTAS BUFFER) 1 1 1 2 2 3 3 3