Loading...
HomeMy WebLinkAboutsite planLEGEND ISTING IRON :W IRON SET I POINT SET ISTING CONCRETE MONUMENT :W CONCRETE MONUMENT [STING PK NAIL :W PK NAIL Q.G.S. MONUMENT NCH MARK (STING RAILROAD SPIKE :W RAILROAD SPIKE [STING AXLE ryry0 I / 221 /VV/ 1// 22`�222 _ - -223 CLOSING oRROR=�0.28' 22z- - _ N UNDA B & LEON K JONES -223� DB 2691 PG 0001 _. PIN 0670-86-2958 _223-22a- - - __ -_ __. _ - \-- _ - - - �. \ 224 _ - 22a - 2za N `J6.22'---OP_0_SED LANDSCAPE BUFFER - pz 53'0T57" zzE 686.64' .-a - zzs.__ � 2- -- - - 224 \ > /LP 430.42' NATURAL -- �/ EXISTING LANDSCAPE BUFFER �I zz, AREA (0.12 AC.) _ / h i 0 1 $ N FFE=225.75 o ac0 o v M / EXISTING 2-STORY TSW zzs.to NEW SSMH 7 FRAME BUILDING . _. -. _.. CO - TOP 224.30 TSW 225.10 INV our 22o.5z In FRAME BUILDING RECREATIONAL (12) PARKS - �zzs----- -- I` _ 226. •- _------------------� AREA / I I=:�iaz•.� �2u_ ---------------226- 3,327 z ---- zze - - -- Z7 SF ® TA 2 ]0 TA JS A 224.00 _ - - 0.08 AC TA 224.26 IB\ \ l rA s. y�l 225 _ TLP VENTURES, LLC 1/ X BOV IP �, -� -� _ EXISTING ASPHALT �. -226 ( I PIN 0670-96-01 F 90D 83 PARKING oW / CLS 22.2.76 row J Y 15W 22A95 �o° LPO A 223 W Q Y (6) PARKS Y - _ 1 Y ` s Boa --- I 2- N 49'13'00" E B __ --v-226 TRACT 2 Y TSA 224.60 m 21.65' - 127,807 SF ' TSW 225,20 Ir - ®+ s $°a 2.93 AC I I i N (TO R/W) u , v TSW 22a.35 O �E2 Nryh US 2zzso - is o z_ - - - - - - N TATA 223.25 A N N 1 N O ry7 I! I y[ s NATURAL N NEW SSH i AREA TOP 6 V IN 9EXISTING 2-STORYINNV OT 219.80 Nww FRAME BUILDING ON 4 CO V a LINDA B & LEON K JONEs O m N ` I a DB 2691 PG 0001 v I - CO\, N I I O rn PIN 0670-86-2059 � TRACT g robsz "9n D4 j (3) EX. �,�� EX. ssMH \ N Z TSW 224.60 16,367 SF s TO 2za.97 `'s 6 PVC 11 '� Nap 2215753 ` - 4 - ...... B m 223 2.67 AC I o co e 51'S1'30" W 111.4 ' `� S 51'40'11" W 183.95' j c \ TO R/ P \ - _ - B"vss - - - e'Iess °': / i'/. -� _ TSW 2z4.3s „ ( - CLS 22200 N / TSW 22185 1 EXISTNG 2-STORY 'OILFRAME BUILDING N a ' TSW 2n.75 e I 1 »__�==�7- 2 u�i I �c2 1 `\\� I --- ------ Z I ' 1 I x TLP VENTURES, LLC r rn DB 2691 PG 0001 ry Tsw 223.60 �Z \' J I I W N I--�-�-- __ -- ---226-- 1 N ; 1 PIN 0670-96-0547 I I 1 w FQ GI �°/ TRACT 1 / i I �Tz mo a N N1 a o I 1 w, 46,454 SF /� tlB ° i m n "7 /I F•I 1 EXISTING ASPHALT 1.07 AC / `-�-� oT= 6p _ it 2. '• N Ni "i �I_ I PARKING (TO R/W)S' 0] � m L ` y � CLS 221.50 � /, 616' 26' 18' 6.5 N � pNj N -22e- C2 I a GIB ; %V 223.35 2 2. RECREATIONAL a #SS r �T 17 �c� zss �_ 1� ____ -- AREA X. 14,237 SF 3 Nv Ire 11 I B -z2s 0.33 AC �7 BI 3.110 1I _ i - - - - - - - - - - - - - - R/ TSW 223.60 Y L INV 217.76 E%.) A _ _ .� _224 - -224 P�Pt / i , INV 217.86 NE'M) _ _ I 1 - A 222 ... PPI �7,y-E a, J`._ OHE_`"'-223-.x?' W OME W _ - - OME W - - N) E W OHE W - OHE }i.. W W 2? rp iSW 22230/ ��, / B� N- /N223 \ --�-- -- ----.- _ --- w- _ - _ - - -. _-- _ _ _ --- - _- / A NEW 15' E5 / = -- E MAIN STREET SR f 532 - - C/ / ,., INV IN 221.50 S i 224 S 50'42'42" W 110.71' NEW1T INV WT 221 W '.� NEW SSMH U2.1 TOP 2221& E% 15' FES / 07 CLS 721.00 NV NY IOUT t218.55 INV OU\22 / / / 1'ry.5 `� / SEX. SSMH \ OHE� - - - - U / 5 1'm/ / TOP N 218. pp R/ 0j PP INV IN 216.90 .75 % / % i S'6�/ INV OUT 206.91 221.65 HEWETT A JR. & BRENDA J. BROWN DB 2535 PG 0732 PIN 0670-85-5992 - / / E% 15• FES ' PP INV OUT 220.7 ry IV S NV IN 220.50 FH z 15' FES 1 INV OUT 220.00 / PPS/ �?o e5� �z Herring -Sutton & Associates, P.A. Engineers - Surveyors - Planners / Firm License #C-2310 2201 Nash Street NW • Nilson, North Carolina 27896 • (252) 291-8887 Meredith Square, LLC Neills Creek Township, Harnett County, NC OWNER/DEVELOPER: MEREDITH SQUARE, LLC PO BOX 143 DUNN, NC 28335 SITE Vicinity Map Not to Scale PIN . . . . . . . . . . . . . . . 0670-86-6402 PROPERTY REFERENCES . . . . . . DB 3364 PG 0700 - PB 98 PG 248 PROPERTY ADDRESS . . . . . . . . 603 MAIN ST. LILLINGTON, NC TOTAL LOT AREA . . . . . . . . . 6.67 AC. NEW SITE AREA . . . . . . . . . . 2.67 AC. ZONING CODE . . . . . . . . . . . RA-30 SETBACKS . . . . . . . . . . 25' ALL SIDES _ PARCEL -I.D. NUMBER 0670-86-7395 DEED REFERENCE. . . . . . . .. DB 3364 PG 700 PLAT REFERENCE. . . . . . . . . PC F SLIDE 450C MAX. ALLOWED DENSITY . . . 60 UNITS (9 UNITS/AC) MF EXISTING BLDGS. . . . . . . . . . 36 UNITS PROPOSED ADDITION . . . . . .. . 24 UNITS (2-BR) REQ'D ADD. PARKING . . . . . 72 SPACES (3 HC) EXIST. IMPERV. AREA . . . . . . 1.67 AC. (25.03%) PROPOSED IMPERV ADD. . . . 1.13 AC. TOTAL IMPERV. AREA . . . . . . 2.80 AC. (41.977) NEW RECREATION AREA . . . . . . 17,564 SF (15%) SUBJECT SITE NOTES: NO PERENNIAL STREAMS OR NATURAL DRAINAGE WAYS CROSS THIS SITE. PROPERTY IS LOCATED WITHIN THE WS-IV-CA WATERSHED DISTRICT. THIS PROPERTY IS NOT LOCATED WITHIN A FLOOD HAZARD ZONE. THERE ARE NO WETLANDS ON SITE AS DELINEATED AT THIS TIME. TRASH REMOVAL FOR THIS SITE IS BY DUMPSTER. PROJECT TO BE SERVED BY MUNICIPAL WATER AND SEWER ASPHALT PARKING LOT TO BE 2" S9.5A OVER 6" OF AGGREGATE BASE. CONCRETE CURB & GUTTER TO BE 30" WIDE TURN -DOWN SIDEWALKS TYPICAL 6.5' WIDE. OTHER SIDEWALKS 4' WIDE U.N.O. GENERAL SITE NOTES: ALL CONSTRUCTION AND MATERIALS TO BE IN ACCORDANCE WITH ALL HARNETT CO. CURRENT STANDARDS AND SPECIFICATIONS. ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE AND MUST BE VERIFIED BY CONTRACTOR. CALL NC1CALL AT 1-800-632-4949 BEFORE DIGGING TO LOCATE EXISTING UTILITIES. ALL OUTDOOR LIGHTING SHALL BE SHIELDED IN SUCH A MANNER THAT NO DIRECT GLARE CAN BE SEEN FROM A MAJOR THOROUGHFARE, AN ADJOINING ZONING DISTRICT, OR FROM ABOVE. DRIVEWAY PERMIT FROM NORTH CAROLINA DEPARTMENT OF TRANSPORTATION REQUIRED PRIOR TO CONSTRUCTION. 10'x70' SIGHT DISTANCE TRIANGLES ARE REQUIRED AT ALL DRIVEWAYS. ALL PLANS ARE REVIEWED FOR COMPLIANCE WITH ICC/ANSI A117,1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES). ALL REQUIRED EXITS ("EXIT") WILL NEED TO BE TREATED AS AN ACCESSIBLE ENTRANCE AS PER ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES). ALL CURB CUTS AND/OR CURB RAMPS MUST MEET ALL REQUIREMENTS IN ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES). W ALL TRAFFIC CONTROL DEVICES (PAVEMENT MARKINGS, SIGNS AND SIGNALS) SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN CONFORMANCE WITH THE STANDARDS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. STANDARD R7-8o RESERVED PARKING AND MAXIMUM PENALTY $250 NCGS 20-37.6 SIGNS L MUST BE INSTALLED IN FRONT OF THE HANDICAP PARKING SPACES. VAN ACCESSIBLE SIGNS) MUST BE PROVIDED IN FRONT OF VAN ACCESSIBLE SPACES. SLOPE OF HANDICAP PARKING AREA MUST NOT EXCEED )/4" RISE PER FOOT PER REQUIREMENTS IN ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND W USABLE BUILDINGS AND FACILITIES). SIDEWALKS MUST NOT EXCEED 20:1/5% GRADE. HANDICAP RAMP SHALL HAVE A SLOPE NO GREATER THAN 11N 12 PER REQUIREMENTS OF ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES). A REGISTERED ENGINEER OR SURVEYOR SHALL SUBMIT SIGNED AND SEALED CERTIFICATION ATTESTING THAT THE BUILDING IS PROPERLY LOCATED ON THE SITE AND THAT SUCH LOCATION IS IN COMPLIANCE WITH THE APPROVED DEVELOPMENT PLAN PRIOR TO APPROVAL OF THE CONSTRUCTION OF THE SURFACE FLOOR SLAB OF THE B BY THE BUILDING INSPECTOR. v&C NaPACE Co40' 0 40' 80, 120' Site Plan Date: July 2018 Scale: 1" = 40' Map No. Drawn by: VLK 17-L-6251A Sheet No. 1 of 1