HomeMy WebLinkAboutsite planLEGEND
ISTING IRON
:W IRON SET
I POINT SET
ISTING CONCRETE MONUMENT
:W CONCRETE MONUMENT
[STING PK NAIL
:W PK NAIL
Q.G.S. MONUMENT
NCH MARK
(STING RAILROAD SPIKE
:W RAILROAD SPIKE
[STING AXLE
ryry0 I /
221 /VV/ 1//
22`�222
_ - -223
CLOSING oRROR=�0.28' 22z- - _
N UNDA B & LEON K JONES
-223� DB 2691 PG 0001 _.
PIN 0670-86-2958
_223-22a- - - __ -_ __. _ - \-- _ - - - �. \ 224
_ -
22a
- 2za
N `J6.22'---OP_0_SED LANDSCAPE BUFFER - pz 53'0T57"
zzE 686.64'
.-a - zzs.__ �
2- -- - -
224 \ > /LP 430.42'
NATURAL -- �/ EXISTING LANDSCAPE BUFFER
�I zz, AREA
(0.12 AC.) _
/ h i
0 1
$ N FFE=225.75 o ac0 o
v M / EXISTING 2-STORY
TSW zzs.to NEW SSMH 7 FRAME BUILDING
. _. -. _.. CO
- TOP 224.30 TSW 225.10
INV our 22o.5z In FRAME BUILDING
RECREATIONAL (12) PARKS - �zzs----- -- I` _
226. •- _------------------�
AREA / I I=:�iaz•.� �2u_ ---------------226-
3,327
z ---- zze - - --
Z7 SF ® TA 2 ]0 TA JS A 224.00 _ - -
0.08 AC TA 224.26 IB\ \ l
rA s. y�l 225 _ TLP VENTURES, LLC
1/ X BOV IP �, -� -� _ EXISTING ASPHALT �. -226 ( I PIN 0670-96-01
F 90D
83
PARKING
oW
/ CLS 22.2.76 row J Y 15W 22A95 �o° LPO
A 223 W Q Y (6) PARKS Y - _ 1
Y ` s Boa ---
I 2- N 49'13'00" E B __ --v-226 TRACT 2 Y
TSA 224.60 m 21.65' - 127,807 SF
' TSW 225,20 Ir - ®+ s $°a 2.93 AC
I I i N (TO R/W) u
,
v TSW 22a.35
O �E2 Nryh
US 2zzso - is o z_ - - - - - -
N TATA 223.25
A N N 1 N O ry7 I! I y[ s
NATURAL
N NEW SSH i
AREA
TOP 6
V IN 9EXISTING 2-STORYINNV OT 219.80
Nww
FRAME BUILDING
ON 4 CO V a LINDA B & LEON K JONEs O m N ` I a
DB 2691 PG 0001 v I - CO\, N I I O rn
PIN 0670-86-2059
�
TRACT g robsz "9n D4 j (3) EX. �,�� EX. ssMH \ N
Z TSW 224.60 16,367 SF s TO 2za.97 `'s 6 PVC 11 '� Nap 2215753
` - 4 - ...... B
m 223 2.67 AC I o
co e 51'S1'30" W 111.4 ' `� S 51'40'11" W 183.95' j
c \ TO R/ P \ - _ - B"vss - - - e'Iess
°': / i'/. -� _ TSW 2z4.3s „ ( -
CLS 22200
N / TSW 22185 1
EXISTNG 2-STORY
'OILFRAME BUILDING N
a
' TSW 2n.75 e I 1 »__�==�7-
2 u�i I �c2 1 `\\� I
--- ------ Z I ' 1 I x TLP VENTURES, LLC
r rn DB 2691 PG 0001
ry Tsw 223.60 �Z \' J I I W N I--�-�-- __ -- ---226-- 1 N ; 1 PIN 0670-96-0547
I I 1 w FQ GI �°/ TRACT 1 / i I �Tz mo a
N N1 a o I 1 w, 46,454 SF /� tlB ° i m n
"7 /I F•I 1 EXISTING ASPHALT 1.07 AC / `-�-� oT= 6p
_ it 2. '• N Ni "i �I_ I PARKING (TO R/W)S' 0] � m
L ` y
�
CLS 221.50 � /, 616' 26' 18' 6.5 N � pNj N
-22e- C2 I a
GIB
;
%V 223.35 2 2.
RECREATIONAL a #SS r �T 17 �c� zss �_ 1� ____ --
AREA
X.
14,237 SF 3 Nv Ire 11 I B -z2s
0.33 AC
�7 BI
3.110 1I _ i - - - - - - - - - - - - - - R/
TSW 223.60 Y L INV 217.76 E%.) A _ _ .� _224 - -224 P�Pt
/ i , INV 217.86 NE'M) _ _
I 1
- A 222 ... PPI �7,y-E a, J`._ OHE_`"'-223-.x?' W OME W _ - - OME W - - N) E W OHE W - OHE }i.. W W
2?
rp
iSW 22230/ ��, / B� N- /N223 \ --�-- -- ----.- _ --- w- _ - _ - - -. _-- _ _ _ --- - _-
/ A
NEW 15' E5 / = -- E MAIN STREET SR f 532 - - C/
/ ,., INV IN 221.50 S i
224 S 50'42'42" W 110.71'
NEW1T
INV WT 221 W
'.� NEW SSMH
U2.1
TOP 2221& E% 15' FES /
07
CLS 721.00 NV NY IOUT t218.55 INV OU\22 / / / 1'ry.5 `� / SEX. SSMH \ OHE� - - - -
U / 5 1'm/ / TOP N 218. pp R/
0j PP INV IN 216.90
.75 % / % i S'6�/ INV OUT 206.91
221.65
HEWETT A JR. & BRENDA J. BROWN
DB 2535 PG 0732
PIN 0670-85-5992 - / / E% 15• FES
' PP INV OUT 220.7 ry
IV S
NV IN 220.50
FH
z
15' FES
1
INV OUT 220.00
/
PPS/ �?o
e5�
�z
Herring -Sutton & Associates, P.A.
Engineers - Surveyors - Planners / Firm License #C-2310
2201 Nash Street NW • Nilson, North Carolina 27896 • (252) 291-8887
Meredith Square, LLC
Neills Creek Township, Harnett County, NC
OWNER/DEVELOPER:
MEREDITH SQUARE, LLC
PO BOX 143
DUNN, NC 28335
SITE
Vicinity Map
Not to Scale
PIN . . . . . . . . . . . . . . . 0670-86-6402
PROPERTY REFERENCES . . . . . . DB 3364 PG 0700 - PB 98 PG 248
PROPERTY ADDRESS . . . . . . . . 603 MAIN ST. LILLINGTON, NC
TOTAL LOT AREA . . . . . . . . . 6.67 AC.
NEW SITE AREA . . . . . . . . . . 2.67 AC.
ZONING CODE . . . . . . . . . . . RA-30
SETBACKS . . . . . . . . . . 25' ALL SIDES _
PARCEL -I.D. NUMBER 0670-86-7395
DEED REFERENCE. . . . . . . .. DB 3364 PG 700
PLAT REFERENCE. . . . . . . . . PC F SLIDE 450C
MAX. ALLOWED DENSITY . . . 60 UNITS (9 UNITS/AC) MF
EXISTING BLDGS. . . . . . . . . . 36 UNITS
PROPOSED ADDITION . . . . . .. . 24 UNITS (2-BR)
REQ'D ADD. PARKING . . . . . 72 SPACES (3 HC)
EXIST. IMPERV. AREA . . . . . . 1.67 AC. (25.03%)
PROPOSED IMPERV ADD. . . . 1.13 AC.
TOTAL IMPERV. AREA . . . . . . 2.80 AC. (41.977)
NEW RECREATION AREA . . . . . . 17,564 SF (15%)
SUBJECT SITE NOTES:
NO PERENNIAL STREAMS OR NATURAL DRAINAGE WAYS CROSS THIS SITE.
PROPERTY IS LOCATED WITHIN THE WS-IV-CA WATERSHED DISTRICT.
THIS PROPERTY IS NOT LOCATED WITHIN A FLOOD HAZARD ZONE.
THERE ARE NO WETLANDS ON SITE AS DELINEATED AT THIS TIME.
TRASH REMOVAL FOR THIS SITE IS BY DUMPSTER.
PROJECT TO BE SERVED BY MUNICIPAL WATER AND SEWER
ASPHALT PARKING LOT TO BE 2" S9.5A OVER 6" OF AGGREGATE BASE.
CONCRETE CURB & GUTTER TO BE 30" WIDE
TURN -DOWN SIDEWALKS TYPICAL 6.5' WIDE. OTHER SIDEWALKS 4' WIDE U.N.O.
GENERAL SITE NOTES:
ALL CONSTRUCTION AND MATERIALS TO BE IN ACCORDANCE WITH ALL HARNETT CO. CURRENT
STANDARDS AND SPECIFICATIONS.
ALL UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE AND MUST BE VERIFIED BY
CONTRACTOR.
CALL NC1CALL AT 1-800-632-4949 BEFORE DIGGING TO LOCATE EXISTING UTILITIES.
ALL OUTDOOR LIGHTING SHALL BE SHIELDED IN SUCH A MANNER THAT NO DIRECT GLARE CAN
BE SEEN FROM A MAJOR THOROUGHFARE, AN ADJOINING ZONING DISTRICT, OR FROM ABOVE.
DRIVEWAY PERMIT FROM NORTH CAROLINA DEPARTMENT OF TRANSPORTATION REQUIRED PRIOR
TO CONSTRUCTION.
10'x70' SIGHT DISTANCE TRIANGLES ARE REQUIRED AT ALL DRIVEWAYS.
ALL PLANS ARE REVIEWED FOR COMPLIANCE WITH ICC/ANSI A117,1-2009 AMERICAN NATIONAL
STANDARD (ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES).
ALL REQUIRED EXITS ("EXIT") WILL NEED TO BE TREATED AS AN ACCESSIBLE ENTRANCE AS
PER ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND USABLE
BUILDINGS AND FACILITIES).
ALL CURB CUTS AND/OR CURB RAMPS MUST MEET ALL REQUIREMENTS IN ICC/ANSI
A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES).
W ALL TRAFFIC CONTROL DEVICES (PAVEMENT MARKINGS, SIGNS AND SIGNALS) SHALL BE
DESIGNED, INSTALLED AND MAINTAINED IN CONFORMANCE WITH THE STANDARDS SET FORTH IN
THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
STANDARD R7-8o RESERVED PARKING AND MAXIMUM PENALTY $250 NCGS 20-37.6 SIGNS
L MUST BE INSTALLED IN FRONT OF THE HANDICAP PARKING SPACES. VAN ACCESSIBLE SIGNS)
MUST BE PROVIDED IN FRONT OF VAN ACCESSIBLE SPACES.
SLOPE OF HANDICAP PARKING AREA MUST NOT EXCEED )/4" RISE PER FOOT PER
REQUIREMENTS IN ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND
W USABLE BUILDINGS AND FACILITIES). SIDEWALKS MUST NOT EXCEED 20:1/5% GRADE.
HANDICAP RAMP SHALL HAVE A SLOPE NO GREATER THAN 11N 12 PER REQUIREMENTS OF
ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD (ACCESSIBLE AND USABLE BUILDINGS
AND FACILITIES).
A REGISTERED ENGINEER OR SURVEYOR SHALL SUBMIT SIGNED AND SEALED CERTIFICATION
ATTESTING THAT THE BUILDING IS PROPERLY LOCATED ON THE SITE AND THAT SUCH
LOCATION IS IN COMPLIANCE WITH THE APPROVED DEVELOPMENT PLAN PRIOR TO
APPROVAL OF THE CONSTRUCTION OF THE SURFACE FLOOR SLAB OF THE B BY THE
BUILDING INSPECTOR.
v&C
NaPACE
Co40' 0 40' 80, 120'
Site Plan
Date: July 2018
Scale: 1" = 40' Map No.
Drawn by: VLK 17-L-6251A
Sheet No. 1 of 1