HomeMy WebLinkAboutINSPECTION W/ ENG LETTER PREPARED 5/10/18, 14:10:46 INSPECTION TICKET PAGE 8 Harnett o0unty INSPECTOR: IVR DATE 5/11/18 ADDRESS . : 1937 RAVEN ROCK RD SUBDIV: CONTRACTOR : RAVEN ROCK MOBILE HOME MOVER PHONE : (919) 775-3600 OWNER . . : WOM2 DEVELOPERS LLC PHONE : PARCEL . . : 13-0621- - -0015- -03- APPL NUMBER: 17-50042257 CP MODULAR HOME DIRECTIONS : T/S: 09/13/2017 04:10 PM JBROCK ---- 421 TOWARD SANFORD GO APPROX 10 MILES TIR NR ON RAVEN ROAR RD GO APPROX 2 MILES LOT TO THE LEFT BESIDE 1909 RAVEN ROCK RD LOT 4A STRUCTURE: 000 000 32X80 4BDR 2BA OFF FRAME MOD FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 4000000.00 SEPTIC - EXISTING? • NEW TANK WATER SUPPLY - COUNTY PERMIT: CPMH 00 CP MODULAR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS A814 01 10/24/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003043288 10/24/17 AP 1937 RAVEN ROCK RD LILLINGTON 27546 T/S: 10/24/2017 10:21 AM SBENNETT 8101 01 10/24/17 TSG R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003043221 10/24/17 AP T/S: 10/23/2017 01:53 PM JBROCK B103 01 12/19/17 TSG R*BLDG FOUND & TEMP SVC POLE VRU #: 003068319 12/19/17 DA 1- NO PLANS ON JOB 2-SEVERAL CENTER PIERS ARE NOT IN THE CENTER 1/3 OF THE FOOTING 3-SEVERAL CENTER LINE PIERS DO NOT HAVE PROJECTION 4-RIGHT REAR FOUNDATION CORNER DOES NOT HAVE PROJECTIONS- AREAS THOUGHOUT THIS FOUNDATION HAVE HEAD AND BED JOINTS GREATER THAN 3/8 . RIGHT REAR CORNER // �1 AREA SEVERAL JOINTS HAVE NO BOND. B103 02 5/11Y R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003125267 ne T/S: 05/08/2018 02:48 PM JBROCK ENG LETTER ON JB'S DESK COMMENTS AND NOTES • L.a,a5"l RJB, P.E., P.A. ROBERT I. BRACKEN ENGINEER SURVEYOR 37(4: Carhomm] Road • S id'¢1. North Carolina 27330 (919) 774-6074 • blbracien itwindstream.net April 12,2018 • • • Harnett County Building Inspections P.O. Box 65 Lillington,NC 27546 REF: Projection Inspection OIT frame Modular On Rock Lit E.1. Womack,Owner Harnett Co, NC Dear Sir/Madam, made an onsite visit to the referenced residential building site on March 21,2018.The purpose of the visit was to examine the projection on the recently placed piers and foundation walls. I asked the owner to remove the soil adjacent to'.the footings so the projection could be observed. The right rear corner was a little less than the 2 minimum. Because of the live and dead loading at this location I have no problem with the project:, as is. There were several areas where the piers had excessive projection. I recommended that tl{e contractor place additional emu to distribute the loading of the pier on the footing. The pier footings with the additional blocks placed now are adequate and will support the live and dead loads as specified in the NC State Residential Building Code,2012,ed. If you have any questions please feel free to call me at 919-774-6074. Sincerely, ,( / • \ & �s L T- Robert J. Bracken, PA 7291 h. F RJB:jeh OF,Q NGtn[� c,-,i l J. Ft"'/