HomeMy WebLinkAboutRev Construction dwgs CCCCFIRST FLOOR FACP NFW2-100 AA AB ELECTRICAL AA AB FSDR EOL AB DEDICATED 12VAC GUTTER AA SD EOL AA FAAP AA AA 110CD AA 30CD AA 30CD AA 110CD F AA 110CD F F F AB 30CD AB 110CD SD F AB AB 110CD DD R AB AB SD SD AB SD AB AB 60CD 60CD DD R 110CDII R M INSTALL ISOLATION MODULES FOR OUTGOING AND INCOMING SLC CIRCUIT. RELAY AND MONITOR FOR HVAC DEFEAT OPERATION >12" RELAY FOR ACCESS CONTROL TIE-IN. SEE F1.0 4 110CD M MONITOR MODULE FOR PAINT BOOTH SUPPRESSION SYSTEM. F0.0 FIRE ALARM TITLE PAGE & RISERDRAWING NO 1 OF 3 A / O AUDIO / ONLY A / V AUDIO / VISUAL ADA AMERICANS WITH DISABILITES ACT ADJ ADJACENT AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ALT ALTERNATIVE ANNUN ANNUNCIATOR APPROX APPROXIMATE ARCH ARCHITECT BLDG BUILDING BTM BOTTOM CCTV CLOSED CIRCUIT TELEVISION â„„CENTER LINE CLG CEILING CM CONTROL MODULE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS COORD COORDINATE CTL CONTROL DC DOOR CONTACT DD DUCT DETECTOR DEMO DEMOLITION DH DOOR HOLDER DWG DRAWING EA EACH EC ELECTRICAL CONTRACTOR ELEC ELECTRICAL ELEV ELEVATOR ENGR ENGINEER EQ EQUAL ES EACH SIDE EW EACH WAY EXIST EXISTING EXT EXTERIOR FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FAEP FIRE ALARM EVACUATION PANEL FE FIRE EXTINGUISHER FLR FLOOR FP FIRE PROTECTION FT FOOT / FEET GA GAGE GC GENERAL CONTRACTOR HD HEAT DETECTOR HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING INFO INFORMATION INSUL INSULATION INT INTERIOR LOC LOCATED / LOCATION MAX MAXIMUM MC MECHANICAL CONTRACTOR MD MOTION DETECTOR MFR MANUFACTURER MIN MINIMUM MISC MISCELANEOUS MM MONITOR MODULE MS MOTION SENSOR N / A NOT APPLICABLE NAC NOTIFICATION APPLIANCE CIRCUIT NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NTS NOT TO SCALE OPP OPPOSITE PNL PANEL REQ'D REQUIRED REV REVISE / REVISION RM ROOM RTU ROOF TOP UNIT SCHED SCHEDULE SD SMOKE DETECTOR SHT SHEET SIM SIMILAR SLC SIGNALING LINE CIRCUITS SPECS SPECIFICATIONS SPKR SPEAKER TEMP TEMPORARY TV TELEVISION TYP TYPICAL UNO UNLESS NOTED OTHERWISE V / O VISUAL ONLY VERT VERTICAL VIF VERIFY IN FIELD WG WIRE GUARD WP WEATHER PROOF W /WITH W / O WITH OUT &AND @ AT F0.0 FIRE ALARM TITLE SHEET & RISER F0.1 FIRE ALARM DETAILS F1.0 FIRE ALARM PLAN DEVICE LEGEND SYMBOL DESCRIPTION DEVICE LEGEND NOTES: 1.SEE DETAIL 1/F0.1 FOR TYPICAL MOUNTING HEIGHTS. 2.SEE F0.1 FOR STANDARD WIRING & INSTALLATION DETAILS. 3.ALL VISUAL NOTIFICATION DEVICES SHALL HAVE A 15 CANDELA RATING UNLESS SHOWN OTHERWISE ON PLANS (i.e. 30cd, 75cd, etc...). 4."XX" SHOWN ON NOTIFICATION APPLIANCES NOTATES NAC CIRCUIT, SEE WIRE LEGEND FOR LIST OF CIRCUITS. FACP SD F XX M T,F,P J FAAP HD DD A V V FIRE ALARM CONTROL PANEL SMOKE DETECTOR HEAT DETECTOR DUCT DETECTOR PULL STATION AUDIO / VISUAL INDICATING DEVICE - WALL MOUNT VISUAL ONLY INDICATING DEVICE - WALL MOUNT MONITOR MODULE (T = TAMPER, F = FLOW, P = PRESSURE) FIRE ALARM ANNUNCIATOR PANEL AUDIO / VISUAL INDICATING DEVICE - CEILING MOUNT VISUAL ONLY INDICATING DEVICE - CEILING MOUNT JUNCTION BOX (HORIZONTAL WIRING) RELAY MODULE REMOTE INDICATOR WITH TEST STATION (KEYED) FOR DUCT DETECTORT XX XX XX C CONTROL MODULE R DH NAC FIRE ALARM REMOTE POWER SUPPLY PANEL DOOR HOLDER J JUNCTION BOX (VERTICAL WIRING / RISER) END OF LINE (EOL) RESISTOR I ISOLATION MODULE REPRESENTS WIRE OR CIRCUIT COMING "IN" REPRESENTS WIRE OR CIRCUIT GOING "OUT" REMOTE INDICATOR FOR DUCT DETECTORIDISPLAY MESSAGE ON FACP LCDACTIVATE ALL HORN/STROBE DEVICESACTIVATE TROUBLE SIGNAL ON THE FACPACTIVATE ALARM SIGNAL ON THE FACPACTIVATE HVAC SHUTDOWNMANUAL PULL STATION1 2 3 4 5 6 7 8 9 10 SMOKE DETECTOR HEAT DETECTOR OPEN CIRCUIT SLC/IDC (TROUBLE) OPEN CIRCUIT - NAC (TROUBLE) GROUND FAULT (TROUBLE) WIRE TO WIRE SHORT (TROUBLE) REMOVAL OF DEVICE (TROUBLE) FACP TROUBLE LOSS OF FIRE ALARM SYSTEM 120V OPERATING POWER A B C D ESYSTEM INPUTS SYSTEM OUTPUTSOPERATING SEQUENCE MATRIX 11 12 13 SPRINKLER TAMPER DUCT SMOKE DETECTOR SPRINKLER WATER FLOW ACTIVATE SUPERVISORY SIGNAL ON THE FACPF Th e In t e g rat i o n o f Tec h n o l o g y an d Li fe Safet y Fire, Security & Communications A Subsidiary of TriTek Fire & Security, LLC FACP NFW2-100 PANEL SCHEDULE PANEL DESCRIPTION LOCATION FAAP N-ANN-80 ELEC/DATA 105 LOBBY 108 ABBREVIATIONS DRAWING INDEX TRITEK PROJECT TEAM FIRE ALARM RISER DIAGRAM FIRE ALARM SYSTEM PROTECTION FIRE ALARM DRAWING NOTES OPERATION SEQUENCE MATRIX SCHEDULES LEGENDS DATE ES CHECKED BY: JA DRAWN BY:CCCC AUTO RESTORATION220 OLIVE FARM DRIVESANFORD, NORTH CAROLINA 27332PROJECT NUMBER:TheIntegrationofTechnologyandLifeSafetyFire, Security & CommunicationsA Subsidiary of TriTek Fire & Security, LLCREVISIONNO.BYDATEFOR CONSTRUCTIONCURRENT PHASE:SUBMITTALROUGH-ININSTALLPROGRAMMINGPUNCH LISTAS BUILTINSPECTIONPRINTED:TECHNICIAN:RETURNED:XX/XX/XXXX/XX/XXXX04-04-18 13499 SECTION A.10.4.4 OF THE NATIONAL FIRE ALARM CODE HANDBOOK STATES THAT SMOKE DETECTION SHALL BE PROVIDED AT THE LOCATION OF EACH FACP, NAC AND SUPERVISING STATION TRANSMITTING EQUIPMENT TO PROVIDE NOTIFICATION OF FIRE AT THAT LOCATION. ·EXCEPTION #1: WHERE AMBIENT CONDITIONS PROHIBIT INSTALLATION OF AUTOMATIC SMOKE DETECTION, AUTOMATIC HEAT DETECTORS SHALL BE PERMITTED. SMOKE DETECTOR INSTALLATION LOCATION: SECTION A.17.4.10 STIPULATES: ·WHERE THE CEILING IS 15ft IN HEIGHT OR LESS, THE SMOKE DETECTOR SHOULD BE LOCATED ON THE CEILING OR THE WALL WITHIN 21ft OF THE CENTERLINE OF THE FIRE ALARM CONTROL UNIT BEING PROTECTED BY THE DETECTOR IN ACCORDANCE WITH 17.3.2.1 ·WHERE THE CEILING EXCEEDS 15ft IN HEIGHT, THE AUTOMATIC SMOKE DETECTOR SHOULD BE INSTALLED ON THE WALL ABOVE AND WITHIN 60in FROM THE TOP OF THE CONTROL UNIT. FACP 1 BACKBOX SCHEDULE DEVICE TYPE PART #QTY.BACKBOX BACKBOX NOTES: = PROVIDE PLASTER RING = PROVIDE WITH EXTENSION OR 218" BOX*** MOUNT NFW2-100 INCLUDED FAAP 1N-ANN-80 HORN/STROBE 12GEC3-24WR 4"x4"x112" STROBE 6GES3-24WR SMOKE DETECTOR 6NP-100 3.5" OCTAGON PULL STATION 6NOT-BG12LX SINGLE GANG 4"x4"x112" SURFACE SURFACE WALL WALL SURFACE SURFACE KEY SWITCH 2RTS151KEY INCLUDED SINGLE GANG RELAY MODULE 4NC-100R 4"x4"x112"SURFACE **ISOLATION MODULE 2ISO-X 4"x4"x112"SURFACE **MONITOR MODULE 1NMM-100 4"x4"x112"SURFACE ** SURFACE VA AA VA 75CD AA V AA V AA EOLAA 1AA 1AA 2AA (TYP BRANCH CIRCUIT)2AA 2AA 1AA MAIN TRUNK LINE FROM FACP OR NAC PANEL WIRE LEGEND LABEL DESCRIPTION PANEL LOCATION A 18-02 UNS SOL FPLR (SLC)FACP 1ST FLOOR B 2#14 THHN, Solid (24VDC)FAAP 1ST FLOOR C #18-02 Shielded, FPLR, Solid FAAP 1ST FLOOR D #18-02 UNS SOL FPLR duct det.SEE PLAN AA (2) #14 THHN, Solid 1ST FLOOR AB 1ST FLOOR(2) #14 THHN, Solid FACP FACP SYSTEM DESIGNER EDDIE STEVENS (NICET 4 - #98485) SALES PERSON JIMMY RUSS FIRE ALARM DRAWING NOTES: 1.ALL FIRE ALARM SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE PROVISIONS OF NFPA, FIRE CODE, BUILDING CODE AND ANSI STANDARDS. 2.ALL CONDUIT TO BE 34" EMT UNLESS NOTED OTHERWISE. 3.FIRE ALARM DEVICES AND MASS NOTIFICATION ALERT DEVICES SHALL BE SYNCHRONIZED. 4.PRIOR TO PROGRAMMING AND ROUGH-IN, COORDINATE ROOM NUMBERS WITH OWNER AND ARCHITECT. 5.VOLTAGE DROP CALCULATIONS ARE BASED ON CONDUIT LOCATIONS SHOWN ON FIRE ALARM DRAWINGS. FINAL CONDUIT LOCATIONS TO BE PROVIDED BY ELECTRICAL CONTRACTOR. 6.JUNCTION BOXES NOT SHOWN FOR CLARITY. JUNCTION BOX LOCATIONS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 7.FIRE ALARM SYSTEM TO BE CLASS 'A' FOR SLC DEVICES, CLASS 'A' FOR INITIATION DEVICES, AND CLASS 'B' FOR NOTIFICATION APPLIANCES. REFER TO FIRE ALARM SPECIFICATION NOTES ON THIS SHEET FOR MORE INFORMATION. FURNISH & INSTALL END-OF-LINE (EOL) RESISTORS WHERE SHOWN ON PLANS. 8.ALL WIRING SHALL BE RUN IN WALLS AND ABOVE CEILING IN METAL RACEWAYS. RACEWAYS SHALL BE RUN CONCEALED WHERE PRACTICAL. 9.SMOKE DETECTORS SHALL BE LOCATED AS NEAR THE CENTER OF THE ROOM AS PRACTICAL. DO NOT LOCATE ANY DETECTOR WITHIN 3'-0" OF AN HVAC SUPPLY GRILLE. PROVIDE AUXILIARY CONTACT ON SMOKE DETECTORS LOCATED IN CORRIDORS AT SMOKE DOORS. WIRE MAGNETIC DOOR HOLDERS THRU AUXILIARY CONTACT TO RELEASE DOOR WHEN THOSE DETECTORS ARE ACTUATED. 10.DUCT DETECTORS SHALL BE TURNED OVER TO MECHANICAL CONTRACTOR FOR INSTALLATION. FIRE ALARM SYSTEM WIRING WILL BE BY TRITEK. CONTROL WIRING WILL BE BY THE MECHANICAL CONTRACTOR. PROVIDE AUXILIARY CONTACT ON EACH DUCT DETECTOR FOR DIVISION 23 USE. A RELAY MODULE AND REMOTE TEST STATION MAY NOT BE DISPLAYED ON PLANS FOR CLARITY. REFER TO DETAIL 3/F0.1 FOR INFORMATION. 11.LOCATE MANUAL PULL STATIONS WITHIN 5'-0" OF THE EXIT DOOR PER NFPA AND IBC REQUIREMENTS. PROVIDE ANY SPECIAL ADAPTER PLATES OR COVER PLATES REQ'D TO MOUNT PULL STATIONS IN DOOR MULLIONS WHERE APPLICABLE. 12.EACH HORN / STROBE LOCATED AT THE END OF A CORRIDOR MUST BE WITHIN 15'-0" OF THE END WALL PER NFPA 72. HORN / STROBES IN CLASSROOMS AND OFFICES MUST BE ROUGHLY CENTERED ON WALL PER NFPA 72. DO NOT ADJUST THE LOCATIONS OF ANY HORN / STROBES WITHOUT CONSULTING THE ENGINEER AND OBTAINING WRITTEN PERMISSION. 13.FIELD VERIFY LOCATION OF FIRE ALARM CONTROL PANEL "FACP" AND FIRE ALARM ANNUNCIATOR PANELS "FAAP" WITH OWNER AND AUTHORITY HAVING JURISDICTION PRIOR TO ROUGH-IN. 14.LETTERS "I" AND "O" ARE NOT USED IN SCHEDULES DUE TO CONFLICTS WITH NUMBERS THAT LOOK SIMILAR. 15.ALL NOTIFICATION APPLIANCES ARE SUPERVISED, THEREFORE REQUIRING A FULL CIRCUIT BETWEEN DEVICES UP UNTIL THE LAST DEVICE WHERE THE END OF LINE RESISTER IS GENERALLY LOCATED. WIRE PATHS THAT ARE BRANCHED OFF FROM THE MAIN TRUNK LINE AND ARE NOT LABELED WITH A CIRCUIT TAG ARE ASSUMED TO HAVE (2) PAIRS OF WIRE IN THE WIRE PATH. SEE EXAMPLE BELOW: (SYMBOLS SHOWN ON EXAMPLE MAY NOT REFLECT EXACT SYMBOLS SHOWN ON PLANS). FIRE ALARM SPECIFICATION NOTES: 1.NFPA-72 (2013), SECTION 12.3.7 STATES: CLASS 'A' AND CLASS 'X' CIRCUITS USING PHYSICAL CONDUCTORS (E.G. METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL BE PERMITTED IN THE SAME CABLE ASSEMBLY (I.E. MULTI-CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY ONLY UNDER THE FOLLOWING CONDITIONS: 1.1.FOR A DISTANCE NOT TO EXCEED 10FT (3.0M) WHERE THE OUTGOING AND RETURN CONDUCTORS ENTER OR EXIT THE INITIATING DEVICE, NOTIFICATION APPLIANCE, OR CONTROL UNIT ENCLOSURES. 1.2.FOR SINGLE RACEWAY DROPS TO INDIVIDUAL DEVICES OR APPLIANCES. 1.3.FOR SINGLE RACEWAY DROPS TO MULTIPLE DEVICES OR APPLIANCES INSTALLED WITH A SINGLE ROOM NOT EXCEEDING 1000FT² (93M²) IN AREA. 2.SECTION A.12.3.7 STATES: A GOAL IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 12 IN. (300 MM) WHERE THE CABLE IS INSTALLED VERTICALLY AND 48 IN. (1.22 M) WHERE THE CABLE IS INSTALLED HORIZONTALLY. 60" TO TOP60" TO CENTER OF DISPLAY PANEL80" TO BOTTOM48" TO TOP MAX4" MIN FIRE PUSH INPULL DOWN SEE NOTE 5PULL STATION HORN, CHIME OR STROBE FIRE ALARM ANNUNCIATOR PANEL (FAAP) FIRE ALARM CONTROL PANEL (FACP) SMOKE DETECTOR AT CORNER6" MINDETECTORS BETWEEN BEAMS12'-0" MAX12" MAX1/2 S S S 1/2 S 3'-0"3'-0" S = SPACE BETWEEN DETECTORS 3 3'-0" MIN DIFFUSER (SUPPLY OR RETURN) S S S = SPACE BETWEEN DETECTORS SMOKE DETECTOR ON SLOPED CEILING (PEAKED) SMOKE DETECTOR ON SLOPED CEILING (SHED) SMOKE DETECTOR ADJACENT TO DIFFUSER 1 2 1 KEYED NOTE SCHEDULE MARK DESCRIPTION LOCATE SMOKE DETECTORS AT BOTTOM OF BEAMS (OR JOISTS) OR AT CEILING. (REDUCE SPACING BY .5 PERPENDICULAR TO BEAM OR JOIST DIRECTION). PER NFPA 72-2013 17.6.33.2 2 LOCATE HEAT DETECTORS AT BOTTOM OF BEAMS IF EITHER D/H < .1 OR W/H < .4: OTHERWISE LOCATE IN BEAM POCKET. 3 LOCATE SMOKE DETECTOR ANYWHERE IN SHADED AREA. PER NFPA 72-2013 17.6.3.4 W D4" MIN12" MAX1/2 S 3'-0" MAX FIRE ALARM DEVICE MOUNTING NOTES: 1.ALL MOUNTING HEIGHTS SHOWN ARE TYPICAL UNLESS NOTED OTHERWISE ON PLANS. 2.VISUAL UNIT (NOTIFICATION): DEVICE 80" ABOVE HIGHEST FLOOR LEVEL OR 6" BELOW CEILING, WHICHEVER IS LOWER (ADA 1993). BOTTOM OF DEVICE 80 AFF (NFPA). 3.AUDIO UNIT (NOTIFICATION): TOP OF UNIT AT LEAST 90" AFF OR 6" BELOW CEILING, WHICH EVER IS LOWER (NFPA). 4.AUDIO / VISUAL UNIT (NOTIFICATION): LOCATION DETERMINED BY VISUAL UNIT REQUIRMENTS (NFPA). 5.PULL STATION (ACTIVATION): HIGHEST OPERABLE PART SHALL NOT BE MORE THAN 48" ABOVE THE FLOOR (FRONT APPROACH) ADA 1993. OPERABLE PART (T-HANDLE) SHALL BE NOT LESS THAN 42" AFF (NFPA).SEE NOTES 2, 490" TO TOPAUDIO ONLY 6" MINSEE NOTE 34 PER NFPA 72-2013 A.17.7.4.1 4 SCALE: 1 F0.1 TYPICAL FIRE ALARM MOUNTING DETAILS NO SCALE POWER FIRE PRE-ALARM SECURITYSUPERVISORYALARM SYSTEMTROUBLE SILENCEDSIGNALS DISABLEDPOINT TESTLAMPRESETSYSTEMDRILLHOLD 2 SECONDSSIGNALSILENCEDSCROLL DISPLAYACKNOWLEDGE 1 Q W 2 E 3 R 4 T 5 Y 6 U 7 I 8 O 9 P 0 SPACENMBVCXZ A S D F G H JKL !,@ =%:\.I ? LOWERCASE SELECTIONNEXT SELECTIONPREVIOUS ENTRYLAST NUMBERINCREMENT RECALL BATTERY MODULE LEVELS OUTPUT DETECTOR Enter Esc LCD-80 ACKGLOBAL TIME SET TIMESELECT ADJ.CONTRAST HOLD FORLAMP TESTSTEPDISPLAY POWER IN COMMON OUTCONTACTSCOMMON IN EARTH GROUNDPOWER OUT EIA-485 OUT (-)EIA-485 OUT (+)EIA-485 IN (-) N.C. TROUBLEEIA-485 IN (+) 5 PER NFPA 72-2013 17.7.3.2.1 5 F0.1 FIRE ALARM DETAILSDRAWING NO 2 OF 3 DATE ES CHECKED BY: JA DRAWN BY:CCCC AUTO RESTORATION220 OLIVE FARM DRIVESANFORD, NORTH CAROLINA 27332PROJECT NUMBER:TheIntegrationofTechnologyandLifeSafetyFire, Security & CommunicationsA Subsidiary of TriTek Fire & Security, LLCREVISIONNO.BYDATEFOR CONSTRUCTIONCURRENT PHASE:SUBMITTALROUGH-ININSTALLPROGRAMMINGPUNCH LISTAS BUILTINSPECTIONPRINTED:TECHNICIAN:RETURNED:XX/XX/XXXX/XX/XXXX02-12-18 13499 SCALE: 2 F0.1 SMOKE / HEAT DETECTOR DETAIL NO SCALE CLASS A OPTIONAL WIRINGFACPTYPICAL WIRING DIAGRAM FOR 2-WIRE LOOP NOTES: 1.NO EOL RESISTOR REQUIRED FOR SLC APPLICATION. 2.EOL REISISTOR REQUIRED FOR HARD WIRE APPLICATION. 3.DO NOT LOOP WIRE UNDER TERMINAL 1 OR 2. BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. 3-1/2" OCTAGON BACKBOX (PROVIDED BY ELECTRICAL CONTRACTOR) SNAP ON DECORATIVE RING DETECTOR BASE 1 2 3 AIR FL O W TEST S W I T C H DUCT CEILING 2 1 4 5 RELAY MODUL E 3 DUCT DETEC T O R KEY NOTE SCHEDULE SYMBOL DESCRIPTION #18 / 2 WIRE (SLC) IN 34" CONDUIT.1 2 (2) #18 / 2 WIRE IN 34" CONDUIT (TEST STATION), OR #18 / 2 WIRE IN 3/4" CONDUIT (REMOTE INDICATOR) 3 4 DUCT DETECTOR MOUNTED IN MECHANICAL DUCTWORK. SEE MECHANICAL DRAWINGS FOR INSTALLATION INFORMATION. 5 TEST SWITCH WITH INDICATOR LIGHT. SEE PLANS FOR MOUNTING LOCATION (CEILING, WALL). RELAY MODULE INSTALLED BY MECH. (TO BE WITHIN 3'-0" FROM DUCT DETECTOR). SCALE: 3 F0.1 NOTIFIER DNR - DUCT DETECTOR WIRING DETAIL NO SCALE NOTES: 1.REFER TO FIRE ALARM DRAWINGS FOR LOCATION AND QUANTITY OF DUCT DETECTORS. 2.REFER TO PLANS FOR SPECIFIED COMBINATIONS (DUCT DETECTOR + TEST SWITCH, DUCT DETECTOR + TEST SWITCH + RELAY MODULE) 3.DUCT DETECTOR TO BE INSTALLED BY MECHANICAL CONTRACTOR. TYPICAL FOR EACH DUCT DETECTOR SHOWN ON PLANS R DD I #18/2 #18/2 STRIP GAUGE 1 2 3 4 SLCSLC FROM FACP TO NEXT ADDRESSABLE DEVICE SCALE: 4 F0.1 NOTIFIER NOT-BG12LX - PULL STATION DETAIL NO SCALE NOTES: 1.REFER TO DETAIL 1/F0.1 FOR MOUNTING HEIGHTS. (+) (+) (-)(-) SCALE: 5 F0.1 RELAY MODULE (NC-100R) NO SCALE RELAY COMMON 2 NORMALLY CLOSED 2 NORMALLY OPEN 2 RELAY COMMON 1 NORMALLY CLOSED 1 UNUSED NORMALLY OPEN 1 (+) (-)SLC (+) (-) TO NEXT DEVICE (+) (-) FROM PANEL OR PREVIOUS DEVICE SYMBOL SHOWN ON PLANS =R (-) (+) FROM NOTIFICATION APPLIANCE OR POWER SUPPLY EOLR OUT TO NEXT DEVICE FROM LAST DEVICEOUT OUTIN IN IN / OUTMOUNTING PLATE (VIEW ROTATED FOR CLARITY) COVER ISOMETRIC INSCALE: 6 F0.1 GENTEX STROBE, HORN / STROBE WIRING DETAIL (GES3-24W & GEC3-24W) NO SCALE Lobby 108 Men 110 Women 109 Office 103 Office 104 Storage 111 Janitor 106 Electrical/ Data 105Classroom101 Paint Booth 113 Paint Mixing 112 Frame Machine 114 Shop Area 115 Classroom 102 Compressor 118 Breakroom 107 Vehicle Lift 117 Vehicle Lift 116 AA AAAA AB AB AB AB AA AA AA AB FACPFAAPAAAA ABAB 30cd 110cd 110cd 110cd 110cd 110cd110cd 30cd 30cd 110cd AB AB 60cd 60cd SD SD SD DD SD DD SD SD AB F F F F F F T T R R 1A,1AA 1A,1AA 1A,1AA 1A 1A 1A,1AA 1A,1AB 1A,1AB 1A,1AB 1A,1AB 2AB L1D01 L1D02 L1D03 L1D04 L1D05 L1D06 L1D07 L1D08 L1M01 L1M02 L1M03 L1M04 L1M05 L1M06 L1M07 L1M08 1 2 SEPARATE CONDUIT FOR ANNUNCIATOR. 3 R L1M09 4 1B,1C 1A EOL 4.7k EOL 4.7k 1A 1A,1AB 1A,1AB 1A,1AB1A,1AB 1A,1AA I I M L1M10 MONITOR MODULE FOR PAINT BOOTH SUPPRESSION SYSTEM. VERIFY LOCATION AND TIE IN CONDUIT TO FOLLOW CLASS A WIRING REQUIREMENTS. F1.0 FIRE ALARM PLANDRAWING NO 3 OF 3 DEVICE LEGEND SYMBOL DESCRIPTION DEVICE LEGEND NOTES: 1.SEE DETAIL 1/F0.1 FOR TYPICAL MOUNTING HEIGHTS. 2.SEE F0.1 FOR STANDARD WIRING & INSTALLATION DETAILS. 3.ALL VISUAL NOTIFICATION DEVICES SHALL HAVE A 15 CANDELA RATING UNLESS SHOWN OTHERWISE ON PLANS (i.e. 30cd, 75cd, etc...). 4."XX" SHOWN ON NOTIFICATION APPLIANCES NOTATES NAC CIRCUIT, SEE WIRE LEGEND FOR LIST OF CIRCUITS. FACP SD F XX M T,F,P J FAAP HD DD A V V FIRE ALARM CONTROL PANEL SMOKE DETECTOR HEAT DETECTOR DUCT DETECTOR PULL STATION AUDIO / VISUAL INDICATING DEVICE - WALL MOUNT VISUAL ONLY INDICATING DEVICE - WALL MOUNT MONITOR MODULE (T = TAMPER, F = FLOW, P = PRESSURE) FIRE ALARM ANNUNCIATOR PANEL AUDIO / VISUAL INDICATING DEVICE - CEILING MOUNT VISUAL ONLY INDICATING DEVICE - CEILING MOUNT JUNCTION BOX (HORIZONTAL WIRING) RELAY MODULE REMOTE INDICATOR WITH TEST STATION (KEYED) FOR DUCT DETECTORT XX XX XX C CONTROL MODULE R DH NAC FIRE ALARM REMOTE POWER SUPPLY PANEL DOOR HOLDER J JUNCTION BOX (VERTICAL WIRING / RISER) END OF LINE (EOL) RESISTOR I ISOLATION MODULE REPRESENTS WIRE OR CIRCUIT COMING "IN" REPRESENTS WIRE OR CIRCUIT GOING "OUT" REMOTE INDICATOR FOR DUCT DETECTORI WIRE LEGEND LABEL DESCRIPTION PANEL LOCATION A 18-02 UNS SOL FPLR (SLC)FACP 1ST FLOOR B 2#14 THHN, Solid (24VDC)FAAP 1ST FLOOR C #18-02 Shielded, FPLR, Solid FAAP 1ST FLOOR D #18-02 UNS SOL FPLR duct det.SEE PLAN AA (2) #14 THHN, Solid 1ST FLOOR AB 1ST FLOOR(2) #14 THHN, Solid FACP FACP FACP NFW2-100 PANEL SCHEDULE PANEL DESCRIPTION LOCATION FAAP N-ANN-80 ELEC/DATA 105 LOBBY 108 DATE ES CHECKED BY: JA DRAWN BY:CCCC AUTO RESTORATION220 OLIVE FARM DRIVESANFORD, NORTH CAROLINA 27332PROJECT NUMBER:TheIntegrationofTechnologyandLifeSafetyFire, Security & CommunicationsA Subsidiary of TriTek Fire & Security, LLCREVISIONNO.BYDATEFOR CONSTRUCTIONCURRENT PHASE:SUBMITTALROUGH-ININSTALLPROGRAMMINGPUNCH LISTAS BUILTINSPECTIONPRINTED:TECHNICIAN:RETURNED:XX/XX/XXXX/XX/XXXXSCHEDULES / LEGENDS KEYPLAN 04-04-18 13499 SCALE: PLAN NORTH 1 F1.0 FIRE ALARM PLAN 1/8" = 1'-0" FACP 1 BACKBOX SCHEDULE DEVICE TYPE PART #QTY.BACKBOX BACKBOX NOTES: = PROVIDE PLASTER RING = PROVIDE WITH EXTENSION OR 218" BOX*** MOUNT NFW2-100 INCLUDED FAAP 1N-ANN-80 HORN/STROBE 12GEC3-24WR 4"x4"x112" STROBE 6GES3-24WR SMOKE DETECTOR 6NP-100 3.5" OCTAGON PULL STATION 6NOT-BG12LX SINGLE GANG 4"x4"x112" SURFACE SURFACE WALL WALL SURFACE SURFACE KEY SWITCH 2RTS151KEY INCLUDED SINGLE GANG RELAY MODULE 4NC-100R 4"x4"x112"SURFACE **ISOLATION MODULE 2ISO-X 4"x4"x112"SURFACE **MONITOR MODULE 1NMM-100 4"x4"x112"SURFACE ** SURFACE KEY NOTE SCHEDULE SYMBOL DESCRIPTION PROVIDE SURGE PROTECTION ON 120VAC TO FACP. INSTALL GUTTER ABOVE FACP. SEE RISER F0.0.1 2 DETERMINE LOCATION OF DUCT DETECTOR KEY SWITCHES PRIOR TO INSTALLATION. SEE F0.1 DETAIL 3 FOR WIRING. VERIFY DUCT DETECTOR LOCATIONS PRIOR TO INSTALLATION. RELAY MODULE FOR ACCESS CONTROL TIE-IN. VERIFY LOCATION PRIOR TO INSTALLATION. 3 4