HomeMy WebLinkAbout13499 Submittal_30JAN18FIRE ALARM SUBMITTAL 1/17/2017 CCCC AUTO RESTORATION 220 OLIVE FARM DRIVE SANFORD, NORTH CAROLINA 27332 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 FIRE ALARM SUBMITTAL 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 Parts List 3 Distributor Documentation 5 Certifications 10 Data Sheets 15 Calculations 41 Table of Contents FIRE ALARM SUBMITTAL 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 PARTS LIST FIRE ALARM SUBMITTAL 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 MANUFACTURER MODEL # Notifier NFW2-100 - Firewarden Fire Alarm Control Panel Notifier N-ANN-80 - Serial Annunciator Notifier NOT-BG12LX - Pull Station Notifier NP-100 - Smoke Detector Notifier DNR - Duct Detector Housing Notifier RA100Z - Remote Indicator Notifier NC-100R - Relay Module Gentex GEC3-24WW - Horn/Strobe (wall mount) Gentex GES3-24WW - Strobe (wall mount) Ditek DTK-120HW - Surge Arrestor #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A DESCRIPTION EQUIPMENT LIST FIRE ALARM SUBMITTAL 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 DISTRIBUTOR DOCUMENTATION TRITEK Fire, Security & Communications A Subsidiary of TriTek Fire & Security, LLC WWW.TRITEKFIRE.COM 6 Woodcross Drive 1313 Walter Street 1212 Broad Street Columbia, South Carolina 29212 Whiteville, NC 28472 Augusta, Georgia 30901 Tel (803) 407-0747 Tel (910) 207-6290 Tel (706) 722-4464 Fax (803) 407-0779 Fax (803) 407-0779 Watts (888) 874-8353 Watts (888) 874-8353 Thank you for selecting TriTek Fire, Security & Communications as the provider of your equipment. Below is a list of items that should be reviewed and/or completed prior to the arrival of a TriTek Technician. Please keep in mind that if some aspects of system testing cannot be completed during the technicians scheduled on site dates ( i.e. Devices not in place, wiring problems, or other trades not on site as needed to complete interconnection and testing) it is the responsibility of the contractor to notify TriTek when the technician will be required back on site. Please be aware that TriTek requires a five (5) business day notification in order to schedule/reschedule a technician. Please review the following items · System wiring cleared of all opens, shorts, and grounds. · System wiring terminated in all panels. · All devices installed. · All equipment provided by others trades that need to be monitored or controlled by the TriTek equipment is to be installed and ready for testing. · Phone lines for Central Station monitoring installed and a monitoring account setup with either TriTek or other third party. (If other than TriTek all account information needs to be on hand) · Fire Marshal Inspection (requires a 5 business day notice to TriTek for technician scheduling) · DHEC Inspection (requires a 5 business day notice to TriTek for technician scheduling) · Elevator Inspection (requires a 5 business day notice to TriTek for technician scheduling) · Customer Training (requires a 5 business day notice to TriTek for technician scheduling) TriTek’s normal business hours are, Monday-Friday, 8am to 5pm, excluding holidays. If after hours testing/work is required this will be billable at TriTek’s current hourly rate. A PO# will have to be received at out Columbia office before a technician can be authorized to work. If you have any questions please contact your TriTek sales representative or TriTek Technical Installation Support. FIRE ALARM SUBMITTAL 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 CERTIFICATIONS FIRE ALARM SUBMITTAL 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 DATA SHEETS DN-60602:A1 • 12/07/2010 — Page 1 of 6 FireWarden-100-2(E) Rev 3 Intelligent Addressable FACP Addressable Fire Alarm Control Panel DN-60602:A1 7101cov.jpgGeneral The Notifier FireWarden-100-2 Rev 3 (NFW2-100) with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The ’s quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS, and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local pro- gramming of the control panel using the PS-Tools Upload/Down- load utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows® XP or greater, a com- patible modem, and PS-Tools—the Upload/Download software kit—may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP’s keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, NP-A100, USB port, NAC circuit diag- nostics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for NFV-25/50ZST, Photo Supervisory and auto-reset- table Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term “FireWarden-100-2” is used in this document to refer to both the FireWarden-100-2 and the FireWarden-100-2E FACPs (Fire Alarm Control Panels). Like- wise, “NFW2-100” refers to NFW2-100E as well. Features • Listed to UL standard 864, 9th edition. • On-board DACT. • Remote site or local USB port upload/download, using PS- Tools. • Four (4) Style Y (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) • Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. • Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or FDU-80, N-ANN-80 or Legacy ACS Annunciators. • ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): –N-ANN-80(-W) Remote LCD Annunciator –N-ANN-I/O LED Driver –N-ANN-S/PG Printer Module –N-ANN-RLY Relay Module –N-ANN-LED Annunciator Module –N-ANN-RLED Annunciator Module alarms only –ROME Relay Option Module Enclosure • ACS & Terminal-mode Annunciators: –ACS Annunciators: Up to 32 Legacy ACM Series annuncia- tors (ACM-16AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. –Terminal-mode Annunciators: Up to 32 Legacy FDU-80 annunciators. • EIA-232 printer/PC interface (variable baud rate) on main cir- cuit board, for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. • Real-time clock/calendar with automatic daylight savings control. • Detector sensitivity test capability (NFPA 72 compliant). Page 2 of 6 — DN-60602:A1 • 12/07/2010 • History file with 1,000-event capacity. • Maintenance alert warns when smoke detector dust accumu- lation is excessive. • Automatic device type-code verification. • One person audible or silent walk test with walk-test log and printout. • Point trouble identification. • Waterflow (nonsilenceable) selection per monitor point. • System alarm verification selection per detector point. • PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: • SLC can be configured for NFPA Style 4, 6, or 7 operation. • SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). • SLC loop maximum length 10,000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): • Four onboard NACs with additional NAC capability using out- put control modules (NC-100). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. • Silence Inhibit and Auto Silence timer options. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. • Selectable strobe synchronization per NAC. • 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: • Autoprogram (learn mode) reduces installation time. • Custom English labels (per point) may be manually entered or selected from an internal library file. • Three Form-C relay outputs (two programmable). • 99 software zones. • Continuous fire protection during online programming at the front panel. • Program Check automatically catches common errors not linked to any zone or input point. •OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-100 requires PS-Tools Programming software, avail- able on www.magni-fire.com). Upload/download system pro- gramming locally to the NFW2-100 Rev 3 in less than one minute. • USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS • AC Power (green) • Fire Alarm (red) • Supervisory (yellow) • Alarm Silenced (yellow) • System Trouble (yellow) • Maintenance/Presignal (yellow) • Disabled (yellow) • Battery Fault (yellow) • Ground Fault (yellow) KEYPAD CONTROLS • Acknowledge/Step • Alarm Silence • Drill • System Reset (lamp test) • 16-key alpha-numeric pad (similar to telephone keypad) • 4 cursor keys •Enter Product Line Information NFW2-100: FireWarden-100-2 Rev 3 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. NFW2-100R: Same as NFW2-100, except in a red backbox. NFW2-100E: Same as NFW2-100, except with 240 VAC opera- tion. 4XTM Reverse Polarity Transmitter Module: Provides super- vised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PS Tools: Programming software for Windows®-based PC computer (cable not included), available on www.firelite.com. DP-9692B: Optional dress panel for FireWarden-100-2 Rev 3. TR-CE-B: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid batter- ies with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E Rev 3. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download program- ming and updating panel firmware. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DN-60408 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; see DN-7114.) DN-60602:A1 • 12/07/2010 — Page 3 of 6 N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DN- 7107.) ROME-B: Relay Option Module Enclosure (order ROME-B for black or ROME for red). Provides one N-ANN-RLY Relay Mod- ule already installed. The ROME Series provides mounting space for one additional Relay Module or one addressable Multi- module. (See Installation Sheet PN 53530.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-char- acter, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the FireWarden-100-2 Rev 3, see the following data sheets (document numbers) ACM-8R (DN-3558), ACS/ACM Series (DN- 0524), LDM Series (DN-0551), FDU-80 (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-100T: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W) duct smoke detector housings. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100: Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 oper- ation). SMB500: Used to mount all modules except the NMM-100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-25. NZM-100-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-25. NOTE: For more information on Compatible Addressable Devicesfor use with the FireWarden-100-2 Rev 3, see the following datasheets (document numbers): N100-ISO (DN-6994), NP-100 series(DN-6995), NI-100 (DN-6996), NH-100 series (DN-6997), ND-100series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/NDM-100/NZM-100 (DN-6999), NC-100/NC-100R (DN-7000),NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM-100-6 (DN-60150). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm²) and no larger than 12 AWG (3.1 mm²). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. Page 4 of 6 — DN-60602:A1 • 12/07/201060417sys2009.wmfANNUNCIATORS ACS/ACM, LDM ANN-BUS DEVICES N-ANN-80, N-ANN-LED, N-ANN-S/PG, N-ANN-I/O ANN-BUS or EIA-485 in ACS mode (two wires) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8R) Optional REVERSE POLARITY/ CITY BOX OUTPUT (4XTM) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES EIA-232 INTERFACE (PIM-24) built into the motherboard FireWarden-100-2 Rev 3 Fire Alarm Control/ Communicator NOTE: System can use either ANN-BUS devices OR ACS-mode annunciators. They cannot be used simultaneously. NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously.EIA-485 INTERFACE (four wires) FDU-80 Up to 6,000 ft. (1825.8 m) between each FDU-80 in the EIA-485 loop, and between each FDU-80 and the FACP. DUCT DETECTORS ND-100, ND-100R, DNR HEAT DETECTORSNH-100, NH-100R, NH-100H SMOKE DETECTORS NP-100, NP-100T, NI-100, NP-A100 MONITOR/CONTROL NMM-100, NZM-100, NDM-100, N100-ISO, NC-100, NC-100R ADDRESSABLE MULTI-MODULE NZM-100-6, NMM-100-10 MINI-MONITOR NMM-100P PULL STATION NOT-BG12LX PRINTER 24 VDC 24 VDC DN-60602:A1 • 12/07/2010 — Page 5 of 6 Page 6 of 6 — DN-60602:A1 • 12/07/2010 System Capacity • Intelligent Signalling Line Circuits......................................... 1 • Addressable device capacity............................................ 198 • Programmable software zones........................................... 99 • ACS Annunciators .............................................................. 32 • ANN-bus devices................................................................ 16 Electrical Specifications AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2 Rev 3(E): 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm²) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batter- ies require an external battery charger such as the CHG-75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block provides connections for two Style Y (Class B) for a total of four Style Y (Class B) or with an optional ZNAC-92 module converts to four Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documenta- tion and Notifier Device Compatibility Document for listed com- patible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each out- put. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a minimum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE- B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x 22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. NFPA Standards The FireWarden-100-2 Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: –LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). – AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). – REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) –PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). – CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). –OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100-2 Rev 3 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635 •FM approved •CSFM: 7165-0028:0235 •MEA: 120-06-E, Volume 2 For ULC-listed version, see DN-60600. NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and Exceder™ is a trademark of Cooper Notification. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com SYSTEM SPECIFICATIONS dn-7114:c • 5/22/09 — Page 1 of 2 N-ANN-80 80-Character LCD Serial Annunciator Annunciators dn-7114:c • A1-65 7114cov.jpgGeneral The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-BUS of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACPs with an ANN-BUS, such as the NFW-50. Features • Listed to UL Standard 864, 9th Edition. • Backlit 80-character LCD display (20 characters x 4 lines). • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill, and Reset. • Control switches can be independently enabled or disabled at the FACP. • Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure • Keyswitch can be enabled or disabled at the FACP. • Enclosure supervised for tamper. • System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. • Local sounder can be enabled or disabled at the FACP. • N-ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. • Time-and date display field. • Surface mount directly to wall or to single, double, or 4" square electrical box. • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting. • Can be remotely located up to 6,000 feet (1,800 m) from the panel. • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). • Up to eight N-ANN-80s can be connected on the ANN-BUS. Controls and Indicators •AC Power •Alarm •Trouble • Supervisory • Alarm Silenced Specifications •Operating voltage range: 18 VDC to 28 VDC. •Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. •Ambient temperature: 32°F to 120°F (0°C to 49°C). •Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). • 5.375” (13.65 cm.) high x 6.875” (17.46 cm.) wide x 1.375” (3.49 cm.) deep. • For use indoors in a dry location. • All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the N-ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL: S635 •FM approved •CSFM: 7120-0028:240 •MEA: 442-06-E Vol. 2 The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supplywhen the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. Page 2 of 2 — dn-7114:c • 5/22/09 ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devicescan be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-BUS communica- tions circuit. To determine the type of wire and the maximum wir-ing distance that can be used with FACP ANN-BUS accessory modules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim-ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*). Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT • 14 to 18 AWG (0.75 - 2.08 mm 2) wire for 24 VDC power cir- cuit is acceptable. • All connections are power-limited and supervised. • A maximum of eight N-ANN-80 modules may be connected to this circuit. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. FACP Wiring to ANN-BUS Device ORDERING OPTIONS: N-ANN-80: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-B: Black surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps)22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. * 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. ANN-BUS and power wiring are supervised and power-limited. ANN-BUS Device NFW-50 DN-7001:D • 4/13/2012 — Page 1 of 2 NOT-BG12LX Addressable Manual Pull Station Intelligent/Addressable Devices DN-7001:D • A1-380 The NOT-BG12LX Addressable Manual Pull Station 6643cov1.jpgGeneral The Notifier NOT-BG12LX is a state-of-the-art, dual-action(i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide-lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonatematerial with a textured finish. Specifications •Shipping Weight: 9.6 oz. (272.15 g) •Normal operating voltage: 24 VDC. •Maximum SLC loop voltage: 28.0 VDC. •Maximum SLC standby current: 375 μA. •Maximum SLC alarm current: 5 mA. •Temperature Range: 32°F to 120°F (0°C to 49°C) •Relative Humidity: 10% to 93% (noncondensing) •For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle,while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 99 on NFW2-100/NFW2-100C, 1 – 50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shallappear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flushmounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed Page 2 of 2 — DN-7001:D • 4/13/2012 NOTIFIER® is a registered trademark of Honeywell International Inc.©2012 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provideaddress setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro-cess. Consult factory for latest listing status. •UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). •MEA: 67-02-E Vol. IV. •CSFM: 7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. DN-6995:D • 2/11/2015 — Page 1 of 2 NP-100(A) Series Addressable Photoelectric Detectors Addressable Devices DN-6995:D • A1-320 General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER’s FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory, PN RA100Z(A). The NP-100R(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detec- tor housings. Features SLC LOOP • Two-wire loop connection. • Unit uses base for wiring. ADDRESSING • Addressable by device. • Rotary, decimal addressing: 01 – 99 with FireWarden-100-2 and NSP-25, and 01 – 50 with FireWarden-50. ARCHITECTURE • Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. • Sleek, low-profile design. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. • Removable cover and insect-resistant screen for simple field cleaning. OPERATION • Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. • Visible LED “blinks” when the unit is addressed (communicat- ing with the fire panel) and latches on in alarm. MECHANICALS • Sealed against back pressure. • Direct surface mounting or electrical box mounting. • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included). OTHER SYSTEM FEATURES • Fully coated circuit boards and superior RF/transient protec- tion. • 94-V0 plastic flammability rating. • Low standby current. OPTIONS • Remote LED output connection, PN RA100Z(A). Applications Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, especially where smol- dering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. NP-100(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation NP-100(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class B) wiring. NP-100R(A) mounts in a DNR(A)/DNRW duct detector housing. Operation Each NP-100(A) series detector uses one of 99 possible addresses on the FireWarden-100-2 and NSP-25, or one of 50 possible addresses on the FireWarden-50 Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the NP-100(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar chamber, the NP-100(A) series is approximately two times more respon- sive than most photoelectric sensors. This makes it a more sta- ble detector. NP-100(A) in B210LP(A) Base 2151_2251B_CEILING.png Page 2 of 2 — DN-6995:D • 2/11/2015 NOTIFIER® and FireWarden® are registered trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a FireWarden-100-2 or FireWarden-50 addressable fire alarm control panel. The results of the sensitiv- ity test can be printed off the FireWarden-100-2 or FireWarden- 50 for record keeping. Specification Voltage range: 15 – 32 VDC (peak). Standby current: 300 µA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched “ON”). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100(A): 0°C to 49°C (32°F to 120°F); for NP-100T(A): 0°C to 38°C (32°F to 100°F). NP-100R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C – 49°C (32°F – 120°F). Relative humidity: 10% – 93%, non-condensing. Listings Listings and approvals below apply to the NP-100(A), NP- 100T(A), and NP-100R(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing status. •UL Listed: S1115. •ULC Listed: S1115. •CSFM: 7272-0028:0231. •MEA: 243-02-E Vol. 2. •Maryland State Fire Marshal: permit 2173. •FM approved. Product Line Information NOTE: “A” suffix indicates ULC Listed model. NP-100: Addressable photoelectric detector; B210LP base included. NP-100A: Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric detector for use with a DNRA/DNRW duct detector housing; B210LP base included. NP-100RA: Same as NP-100R with ULC Listing for use with a DNRA duct detector housing; B210LPA base included. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to low- profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with NP-100(A) only; box of 10. WCK-200B: White detector covers for use with NP-100(A) only; box of 10. DN-60429:C1 • 4/19/2012 — Page 1 of 2 DNR(A)/DNRW InnovairFlex Intelligent Non-Relay Photoelectric Duct Smoke Detector Intelligent Devices DN-60429:C1 General The Notifier InnovairFlex® DNR(A) intelligent non-relay photo-electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions,operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20°C to 70°C), and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Notifier InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Notifier InnovairFlex duct smoke detector can be custom-ized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. Features • Photoelectric, integrated low-flow technology. • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to20.32 m/s). • Versatile mounting options: square or rectangular configu- ration. • Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non-condensing). • Patented sampling tube installs from front or back of the detector with no tools required. • Cover tamper signal. • Increased wiring space with a newly added 3/4” conduit knockout. • Available space within housing to accommodate mounting of a relay module. • Easily accessible code wheels on sensor head (sold sepa- rately). • Clear cover for convenient visual inspection. • Remote testing capability. • Requires com line power only. • Accommodates the installation of an addressable relaymodule, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm)Width, 2.5 in (6.6 cm) Depth. Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 158°F (-20°C to 70°C). Storage Temperature Range: -22°F to 158°F (-30°C to70°C). Operating Humidity Range: 0% to 95% relative humidity (non-condensing). Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visi- ble and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Agency Listings and Approvals Consult product manual for lists of compatible UL-Listeddevices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. •UL: S911, S3705. •ULC: S635. Device Standby Alarm RA100Z 0mA 12 mA Max RTS151/ RTS151KEY 0mA 12mA Max intelligent innovair- Page 2 of 2 — DN-60429:C1 • 4/19/2012 Notifier® and FlashScan® are a registered trademark of HoneywellInternational Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. •CSFM: 3242-1653:0209. • FM approved. Product Line Information NOTE: “A suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). FSP-851R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851(A): Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profilephotoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft (0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6to 1.2 m). DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH400OE-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS151(A): Remote test station. RTS151KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 orhigher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power forremote test applications. dn-60535:b1 • 1/27/12 — Page 1 of 4 Duct Smoke Detector Accessories for Notifier/System Sensor Products Miscellaneous dn-60535:b1 60535cov.wmfGeneral Duct smoke detector accessories add functionality to the duct smoke system by allowing quick, convenient inspections at eye level and effective audible and visual notification options. All System Sensor duct smoke detectors and accessories are UL listed. Specifications APA151 PIEZO ANNUNCIATOR The APA151 piezo annunciator, which replaces the APA451with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicatepower status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a systemcontrol panel, to comply with NFPA 90A. MHR/MHW MINI-HORNS The MHR and MHW SpectrAlert® Advance mini-horns featuretemporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. APA151 Piezo Annunciator Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 32°F to 120°F (0°C to 49°C) Relative Humidity 10 to 93%, non-condensing Wire Gauge 12 to 18 AWG Dimensions 4.6” H x 2.9” W x .45” D APA151.wmfMHR.wmf, MHW.wmfMHR/MHW SpectrAlert Advance Mini-Horns Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync-Circuit™ Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC17 mA RMS max. at 8 to 17.5 Volts FWR29 mA RMS max. at 16 to 33 Volts DC25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12 to 18 AWG Dimensions 4.6”H x 2.9”W x 0.45”D Page 2 of 4 — dn-60535:b1 • 1/27/12 RA100Z/RA100ZA REMOTE ANNUNCIATORS The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LEDprovides visual indication of an alarm condition. RTS151/RTS151KEY REMOTE TEST STATIONS The RTS151 and RTS151KEY remote test stations are auto- matic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi-colored LED that alter- nates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. RTS2/RTS-AOS MULTI-SIGNALLING ACCESSORIES The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. RA100Z/RA100ZA Remote Annunciator Voltage Range Conventional System: 3.1 to 32 VDCIntelligent System: 18 to 32 VDC Maximum Alarm Current 10 mA Dimensions 4.6”H x 2.8”W x 1.3”D RTS151 Remote Test Station Power Requirements Alarm LED 2.8 to 32 VDC, 10 mA max.Total Current: 95 mA max. Test Switch 10 VA @ 32 VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4.8”H x 2.9W x 1.4”D RA100Z.wmfRTS151.wmf, RTS151KEY.wmfRTS151KEY Remote Test Station with Key Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max.Alarm LED (RED): 2.8 to 32 VDC, 12 mA max. Alarm Response Time 40 seconds max. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4.6”H x 2.75W x 1.8”D RTS2 and RTS-AOS Multi-signaling Accessory Voltage 20 to 29 VDC Power Requirements Standby: 3.0 mA max.Trouble: 16.0 mA max.Alarm without Strobe: 30 mA max.Alarm with Strobe: 55 mA max. Sounder 85 dBA at 10 ft. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8”W x 5.3”H x 1.6”D RTS-AOS.wmf, AOS.wmf dn-60535:b1 • 1/27/12 — Page 3 of 4 Product Line Information APA151: Piezo Annunciator MHR: Mini-Horn, Red MHW: Mini-Horn, White RA100Z/RA100ZA: Remote Annunciator RTS151: Remote Test Station RTS151KEY: Remote Test Station with Key RTS2: Multi-signaling Accessory AOS: Add-On Strobe RTS2-AOS: Multi-Signaling Accessory Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49ºC/32 – 120ºF and at a relative humidity 93% ± 2% RH (noncondensing) at 32ºC ± 2ºC (90ºF ± 3ºF). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27ºC/60 – 80ºF. Agency Listings and Approvals The listings and approvals below apply to the basic products. In some cases, certain modules may not be listed by certainapproval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S4011 (APA 151, MHR, MHW), S2522 (RTS2, RA100Z, RTS151, RTS151KEY, RTS2-AOS) • FM Approved • CSFM: 7135-1653:0212 Page 4 of 4 — dn-60535:b1 • 1/27/12 FlashScan®, NOTIFIER® and System Sensor® are registered trademarksof Honeywell International Inc.©2012 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. dn-60383:A2 • 06/17/10 — Page 1 of 2 NC-100R(A) Relay Module for FireWarden Series Panels Addressable dn-60383:A2 General The NC-100R(A) Addressable Relay Module provides NOTI-FIER’s FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED “blinks” green each time a communication is received from the control panel and turns on in steady when activated. • High noise immunity (EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct Decade entry of address: 01 – 99 with the FireWar- den-100-2(C) and 01 – 50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to resetfour-wire smoke detector power. Construction • The face plate is made of off-white heat-resistant plastic. • Controls include two rotary switches for direct-dial entry of address setting. • The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-100R(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 μA direct poll (CLIP mode), 255 μA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A NC-100R(A)60379cov.jpg Page 2 of 2 — dn-60383:A2 • 06/17/10 NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL/ULC Listed: S635. •CSFM approved: file 7300-0028:230. • FM approved. •MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document I56-2593-001 and refer to the SLC Wiring Manual, document 52304. GEC3/GES3 12 &24 VDC S E R I E S Standard Features •Nominal voltage 12VDC and 24VDC •24VDC units have field selectable candela options of 15,30,60,75 &110 •12VDC units have field selectable candela options of 15,30,60 &75 •GEH horn is available in 12VDC or 24VDC •Super-Slide®Bracket -Ease of Supervision Testing •Checkmate®-Instant Voltage Verification •Unit Dimensions:5”(12.7 cm)high x 4.5”(11.43 cm)wide x 2.5”(6.35 cm)deep •Synchronize strobe and/or horn with Gentex AVSM Control Module •Prewire entire system,install mounting bracket,then install signals •Documented lower installation and operating costs •Input terminals accept 12 to 18 AWG •Switch selection for high or low dBA •Switch for chime,whoop,mechanical and 2400Hz tone •Tamperproof re-entrant style grill •Switch for continuous or temporal 3 tone (not available on whoop tone) •Surface mount with the GSB (Gentex Surface Mount Box) •Silence horn while strobes remain flashing •Faceplate available in red or off-white Applications The Commander3 Series is a low profile strobe and horn/strobe combination that offers dependable audible and visual alarms and the absolute lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30,60,75,and 110 candela.The 12VDC offers tamperproof field selectable candela options of 15,30,60,and 75 candela. The Commander3 Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone,a chime and whoop tone.All tones are easy for the professional to change in the field by using switches. The GE3 Series has a minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. The Commander3 Series is shipped with a standard 4"metal mounting plate which incorporates the popular Super-Slide®feature that allows the installer to easily test for supervision.The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander3 also features the patented Checkmate®-Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The GE3 Series appliances are ANSI/UL 464 and ANSI/UL 1971,listed for use with fire protective systems and are warranted for three years from date of purchase. Commander3 Series Selectable Candela Evacuation Signals Product Listings Product Compliance ••NNFFPPAA 7722 ••AAmmeerriiccaannss wwiitthh DDiissaabbiilliittiieess AAcctt ((AADDAA)) ••QQuuaalliittyy MMaannaaggeemmeenntt SSyysstteemm iiss cceerrttiiffiieedd ttoo:: IISSOO 99000011::22000088 ••AANNSSII//UULL 446644 && AANNSSII//UULL 11997711 LLiisstteedd ••FFMM AApppprroovveedd ••CCSSFFMM::77113355--00556699::112222 ((GGEECC33--2244 && GGEEHH--2244)) 77112255--00556699::112233 ((GGEESS33--2244)) 77112255--00556699::112299 ((GGEESS33--1122)) 77113355--00556699::113300 ((GGEECC33--1122 && GGEEHH--1122)) ••MMEEAA::228855--9911--EE ((GGEECC33--2244 && GGEESS33--2244)) 558800--0066--EE ((GGEECC33--1122 && GGEESS33--1122)) LL oo ww ee ss tt CC uu rr rr ee nn tt DD rr aa ww AA vv aa ii ll aa bb ll ee !!!! Patents ••77,,337755,,661177 MMaayy 2200,, 22000088 GES3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Strobe GEC3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Horn/Strobe MMooddeell DDeessiiggnnaattiioonnss:: W = Wall mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). PPllaaiinn uunniittss aarree nnoonn--rreettuurrnnaabbllee.. ALERT bezel available AGENT bezel available GEH 12VDC or 24VDC Low Profile Evacuation Horn NOTES: •Operating temperature: 32°to 120°F (0° to 49°C). The GEC3 and GES3 Series is not listed for outdoor use. The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. •For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12VDC models are DC only. *Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). 11 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. MMooddeell NNuummbbeerr PPaarrtt NNuummbbeerr NNoommiinnaall VVoollttaaggee RReevveerrbbeerraanntt ddBBAA @@ 1100fftt..,, ppeerr AANNSSII//UULL 446644 IInn AAnneecchhooiicc RRoooomm ddBBAA @@1100fftt.. GEH12-R 904-1239-002 12VDC 62-82 100 GEH12-W 904-1241-002 12VDC 62-82 100 GEH24-R 904-1205-002 24VDC 62-82 100 GEH24-W 904-1207-002 24VDC 62-82 100 MMooddeell NNuummbbeerr PPaarrtt NNuummbbeerr NNoommiinnaall VVoollttaaggee CCaannddeellaa ((AANNSSII//UULL 11997711)) GES3-12WR 904-1235-002 12 VDC 15, 30, 60, 75 GES3-12WW 904-1237-002 12 VDC 15, 30, 60, 75 GES3-24WR 904-1321-002 24 VDC 15, 30, 60, 75, 110 GES3-24WW 904-1319-002 24 VDC 15, 30, 60, 75, 110 MMooddeell NNuummbbeerr PPaarrtt NNuummbbeerr NNoommiinnaall VVoollttaaggee CCaannddeellaa ((AANNSSII//UULL 11997711)) RReevveerrbbeerraanntt ddBBAA @@ 1100fftt..,, ppeerr AANNSSII//UULL 446644 IInn AAnneecchhooiicc RRoooomm ddBBAA @@ 1100fftt.. GEC3-12WR 904-1231-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-12WW 904-1233-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-24WR 904-1317-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GEC3-24WW 904-1315-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GE3-24 Product Horn Current Ratings HHoorrnn MMooddee MMiinniimmuumm ddBBAA @@ 1100fftt..,, ppeerr UULL 446644 ((HHIIGGHH)) MMiinniimmuumm ddBBAA @@ 1100fftt..,, ppeerr UULL 446644 ((LLOOWW)) RReegguullaatteedd 2244VVDDCC MMaaxx.. OOppeerraattiinngg @@ HHiigghh SSeettttiinngg ((mmAA)) Temp 3 2400Hz 78 71*28 Temp 3 Mechanical 76 70*25 Temp 3 Chime 70*66*15 Continuous 2400Hz 81 74*28 Continuous Mechanical 80 72*25 Continuous Chime 70*66*15 Whoop 82 69*56 UP TO 30% CURRENT DRAW REDUC- TION GE3 Product Strobe Current Ratings (mA) 1122VVDDCC ((88--1177..55 VVoollttss))2244VVDDCC ((1166--3333 VVoollttss)) Candela 1122VVDDCC UL Max1 24VDC UL Max1 15cd 110066mmAA 92mA 30mA 42mA 30cd 113311mmAA 141mA 35mA 58mA 60cd 118866mmAA 260mA 66mA 97mA 75cd 223377mmAA 312mA 80mA 116mA 110cd 103mA 161mA GE3-12 Product Horn Current Ratings HHoorrnn MMooddee MMiinniimmuumm ddBBAA @@ 1100fftt..,, ppeerr UULL 446644 ((HHIIGGHH)) MMiinniimmuumm ddBBAA @@ 1100fftt..,, ppeerr UULL 446644 ((LLOOWW)) RReegguullaatteedd 1122VVDDCC MMaaxx.. OOppeerraattiinngg @@ HHiigghh SSeettttiinngg ((mmAA)) Temp 3 2400Hz 76 69*29 Temp 3 Mechanical 75 68*26 Temp 3 Chime 62*60*13 Continuous 2400Hz 79 74*29 Continuous Mechanical 78 72*26 Continuous Chime 63*61*13 Whoop 78 71*55 TTOONNEE SWITCH POSITION345Mechanical Temporal 3 ON ON ONMechanical - Continuous OFF ON ON2400Hz - Temporal 3 ON OFF ON2400Hz - Continuous OFF OFF ONChime - Temporal 3 ON ON OFFChime - Continuous OFF ON OFFWhoopONOFFOFFWhoopOFFOFFOFF NOTE: •SSwwiittcchh PPoossiittiioonnss 11 aanndd 22 iinn tthhee OOFFFF ppoossiittiioonn ttoo sseelleecctt iissoollaatteedd hhoorrnn aanndd ssttrroobbee ppoowweerr iinnppuuttss •SSwwiittcchh PPoossiittiioonn 66 OONN == HHIIGGHH ddBBAA •SSwwiittcchh PPoossiittiioonn 66 OOFFFF == LLOOWW ddBBAA Tone Switch Locations Gentex Super-Slide® Mounting Bracket Allows the installer to pre-wire the system, test for system supervision, remove the signal head until occupancy, switch out Gentex signals without changing mounting brackets and has locking edge connec- tor for snap-in-place installa- tion. Gentex Checkmate®Instant Voltage Verification It is often necessary to confirm the volt- age drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without remov- ing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NNOOTTEE:: CCaarree sshhoouulldd bbee ttaakkeenn ttoo nnoott sshhoorrtt tthhee tteesstt pprroobbeess.. To remove bezel, grip both sides of bezel and pull in a downward and out- ward motion. MODEL SELECTION MARKER Candela selection slid- er switch. Depress center and slide switch to desire brightness level. Break off pin and insert into hole at the bottom of the selector to lock candela setting. Signal must be removed from bracket and pin pushed for- ward from backside out of hole to change can- dela. GEC3/GES3 12 & 24 VDC S E R I E S 551-0050-05 The audible and/or visible signal shall be Gentex GEH, GES3, GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc. per ANSI/UL 1971 and/or ANSI/UL 464. The notification appliance shall also be listed with Factory Mutual Listing Service (FM), the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either con- tinuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble sig- nal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave recti- fied power for 24VDC models or a voltage range of 8-17.5 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 28 pounds per carton NOTES: •All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocal is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. •FFOORR SSYYNNCCHHRROONNIIZZAATTIIOONN WWIIRRIINNGG IINNFFOORRMMAATTIIOONN,, RREEFFEERREENNCCEE AAVVSSMM CCOONNTTRROOLL MMOODDUULLEE DDAATTAA SSHHEEEETT ((555511--00003311)) AANNDD//OORR AAVVSSMM CCOONNTTRROOLL MMOODDUULLEE MMAANNUUAALL ((555500--00228844)) FFOORR SSYYNNCCHHRROONNIIZZAATTIIOONN MMOODDUULLEE WWIIRRIINNGG DDIIAAGGRRAAMMSS.. AAVVSSMM CCOONNTTRROOLL MMOODDUULLEE DDAATTAA SSHHEEEETT AANNDD MMAANNUUAALL CCAANN BBEE OOBBTTAAIINNEEDD AATT hhttttpp::////wwwwww..ggeenntteexx..ccoomm OORR CCAALLLL GGEENNTTEEXX CCOORRPPOORRAATTIIOONN AATT 11--880000--443366--88339911.. •WWhheenn ssyynncchhrroonniizziinngg tthhee GGEE33 1122VVDDCC SSeerriieess,, tthhee GGeenntteexx AAVVSSMM ccoonnttrrooll mmoodduullee oorr GGeenntteexx ssyynncchhrroonniizzaattiioonn pprroottooccaall MMUUSSTT bbee uusseedd.. Important Notice: These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpreta- tion of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws, regu- lations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Architect & Engineering Specifications Conventional Wiring Diagrams for Emergency Notification Evacuation Series DTK-HW Series Equipment Panel/Dedicated Circuit Surge Protective Device General Product Specifications DTK-120HW DTK-120/240HW Product Features • Available for Popular 120V and 120/240V systems • DTK-120HW approved for 20A circuit breakers • Diagnostic LED indicates ground presence, system power and SPD function • Weatherproof enclosure • Small footprint enables installation in a variety of locations • Available for popular 120V, and 120/240V systems • Complies with ANSI/IEEE C62.41 and C62.45 Category B standards • Ten Year Limited Warranty One DITEK Center 1720 Starkey Road Largo, FL 33771 1-800-753-2345 Technical Support: 1-888-472-6100 www.ditekcorp.com Document: SPS-100057-001 Rev 10 9/13 ©2013 DITEK Corp. Specification Subject to Change Specifications Agency Approvals: UL 1449, 3rd Edition, cUL IEEE Location Category: Category B Protector Type: SPD Type 2 Protection Modes: L-G, L-N, N-G Response Time: <1ns Temperature Range: -40°F – 185°F (-40°C – 85°C) Maximum Humidity: 95% non-condensing Operating Frequency: 0Hz – 400Hz Dimensions: 2.93” x 2.83” x 1.68” (74.4mm x 71.9mm x 42.7mm) Connection: ¾” diameter threaded fitting Weight: .5lb. (227g) Housing: ABS DITEK’s HW series of surge protectors are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. 3,000A 10,000A 700V L-N, L-G; 600V N-G 130V 19,500A Single Φ (2W + G), 120VAC 120HW 3,000A 10,000A 700V L-N, L-G; 600V N-G; 1200V L-L 130/260V 13,000A/ Phase 6,500A/ Mode Split Φ (3W + G), 120/240VAC 120/240HW MCOV UL1449, 3rd Ed. In Rating UL 1449, 3rd Ed. V.P.R. Short Circuit Current Rating Peak Surge Current Service Wiring Model Selection: DTK- FIRE ALARM SUBMITTAL 113 Walter Street Phone: (910) 207-6290 Whiteville, NC 28472 Columbia: (803) 407-0747 Florence: (843) 664-8811 Augusta, GA: (706) 722-4464 www.tritekfire.com WATS SC/GA (888) 874-8353 CALCULATIONS Project #:13499 Date: Panel Label:FACP Standby Hours:24 10 STANDBY CURRENT PER UNIT (AMPS) QTY TOTAL STANDBY CURRENT PER ITEM ALARM CURRENT PER UNIT (AMPS) QTY TOTAL ALARM CURRENT PER ITEM 0.30000 x 1 = 0.30000 0.39000 x 1 = 0.39000 0.00000 x 7 = 0.00000 0.18900 x 7 = 1.32300 0.00000 x 5 = 0.00000 0.04200 x 5 = 0.21000 0.00000 x 2 = 0.00000 0.08600 x 2 = 0.17200 0.00000 x 1 = 0.00000 0.05800 x 1 = 0.05800 0.00000 x 2 = 0.00000 0.12500 x 2 = 0.25000 0.00000 x 1 = 0.00000 0.07000 x 1 = 0.07000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.03700 x 1 = 0.03700 0.04000 x 1 = 0.04000 0.00038 x 6 = 0.00228 0.00500 x 6 = 0.03000 0.00030 x 8 = 0.00240 0.00650 x 8 = 0.05200 0.00000 x 2 = 0.00000 0.01200 x 2 = 0.02400 0.00030 x 3 = 0.00090 0.00510 x 3 = 0.01530 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 0.00000 x 0 = 0.00000 REQUIRED STANDBY TIME (HRS) NFPA 72 TOTAL SYSTEM STANDBY CURRENT (AMPS) REQUIRED STANDBY CAPACITY (AMP-HOURS) REQUIRED ALARM TIME (HOURS) NFPA 72 TOTAL SYSTEM ALARM CURRENT (AMPS) REQUIRED ALARM CAPACITY (AMP- HOURS) 24 x 0.3426 =8.2219 0.166 x 2.6343 =0.4373 REQUIRED STANDBY CAPACITY (AMP- HOURS) REQUIRED ALARM CAPACITY (AMP- HOURS) SAFETY FACTOR ADJUSTED BATTERY CAPACITY (AMP- HOURS) 8.22 +0.4373 =x 120%=10.391 12AHBATTERY SUPPLIED FOR PROJECT NOT-BG12LX NP-100 RA100Z NC-100R TOTAL CAPACITY (AMP-HOURS) 8.6592 TOTAL SYSTEM STANDBY CURRENT (AMPS)0.3426 TOTAL SYSTEM ALARM CURRENT (AMPS) 2.6343 NFW2-100 Device Type GEC3-24WW15 N-ANN-80 GEC3-24WW60 GES3-24WW30 GEC3-24WW30 GES3-24WW15 GEC3-24WW110 FACP BATTERY CALCULATIONS Project Name:CCCC AUTO RESTORATION 1/17/2018 Calculations provided by Tritek Fire & SecurityModel Number:NFW2-100 Alarm Minutes: Project #:13499Date:Panel Label:FACP1.5AmpsVoltage Voltage Voltage20.4AmpsCurrent Distance Drop Current Distance Drop Current Distance Drop16Amps1.023 3491.051.023 3490.9011.023 3490.9011.023Amps19.3519.5019.5040Ft Wire Ohm's 5.13% 4.42% 4.42%24Hours0.0166Gauge Per 100010Minutes0.16614 2.52514 2.525 18=6.385 16=4.01614=2.52512=1.59 10=0.99Distance18-14 Awg = Solid Conductors 12-10 Awg = Stranded ConductorsfromNotes:DeviceDevice previous At Drop from PercentNumberCurrent device Device source DropDevice 1 GEC3-24WW 110 0.189 40 20.19 0.207 1.01%Device 2 GES3-24WW 15 0.042 40 20.02 0.375 1.84%Device 3 GES3-24WW 15 0.042 5 20.00 0.395 1.94%Device 4 GEC3-24WW 30 0.086 42 19.85 0.554 2.72%Device 5 GEC3-24WW 30 0.086 45 19.70 0.705 3.46%Device 6 GEC3-24WW 110 0.189 56 19.53 0.868 4.26% Minimum Spare Capacity Required20%0.20Device 7 GEC3-24WW 110 0.189 60 19.41 0.986 4.83% Current Draw Capacity Used68%0.682Device 8 GEC3-24WW 110 0.189 60 19.35 1.047 5.13% Capacity (Not including Spare) 12%0.88Device 9 EOL 4.7K10.011 1 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%None 19.35 1.047 5.13%Totals: 1.023 349 19.35End of Line VoltagePart NumberSpare CapacityTotal Amp Per Ckt:Wire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device in any method must not be lower than the manufacturers listed minimum operating voltage (IE: rated operating voltage 20-32 VDC).Percent DropEnd of Line and Load Centering Methods use only the wire guage for the first device to sourceStandard Wire Resistance in Ohms per 1000 feet.End of Line Voltage End of Line VoltagePercentage DropVoltageCandelaEnter current in amps1/17/2018Project Name:Point to Point MethodCIRCUIT IS WITHIN LIMITS Location of Circuit:Model #:NFW2-100 Wire Gauge for balance of circuit:End of Line VoltageCircuit Number as noted on drawings:AATotals Totals TotalsEnd of Line MethodCCCC AUTO RESTORATION.150 = 150 maNominal System Voltage: VOLTAGE DROP CALCULATIONSDistance from source to 1st device:Standby:Alarm:Percentage DropMinimum Device Voltage: Total Circuit Current:Calculations provided by Tritek Fire & SecurityLoad Centering MethodCIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITSMinimum SpareCapacity RequiredCurrent DrawCapacity UsedCapacity (Notincluding Spare) Project #:13499Date:Panel Label:FACP1.5AmpsVoltage Voltage Voltage20.4AmpsCurrent Distance Drop Current Distance Drop Current Distance Drop16Amps1.082 3911.081.082 3911.0681.082 3911.0681.082Amps19.3219.3319.3331Ft Wire Ohm's 5.30% 5.24% 5.24%24Hours0.0166Gauge Per 100010Minutes0.16614 2.52514 2.525 18=6.385 16=4.01614=2.52512=1.59 10=0.99Distance18-14 Awg = Solid Conductors 12-10 Awg = Stranded ConductorsfromNotes:DeviceDevice previous At Drop from PercentNumberCurrent device Device source DropDevice 1 GES3-24WW 15 0.042 31 20.23 0.169 0.83%Device 2 GES3-24WW 30 0.058 5 20.20 0.196 0.96%Device 3 GEC3-24WW 110 0.189 50 19.96 0.444 2.17%Device 4 GES3-24WW 15 0.042 42 19.79 0.612 3.00%Device 5 GES3-24WW 15 0.042 46 19.61 0.786 3.85%Device 6 GEC3-24WW 110 0.189 5 19.60 0.804 3.94% Minimum Spare Capacity Required20%0.20Device 7 GEC3-24WW 110 0.189 40 19.49 0.909 4.46% Current Draw Capacity Used72%0.721Device 8 GEC3-24WW 60 0.125 56 19.40 1.003 4.92% Capacity (Not including Spare) 8%0.92Device 9 GEC3-24WW 60 0.125 50 19.35 1.055 5.17%Device 10 GEC3-24WW 15 0.070 65 19.32 1.081 5.30%Device 11 EOL 4.7K 1 0.011 1 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%None 19.32 1.081 5.30%Totals: 1.082 391 19.32CIRCUIT IS WITHIN LIMITSProject Name: CCCC AUTO RESTORATION 1/17/2018Calculations provided by Tritek Fire & SecurityModel #:NFW2-100Location of Circuit:Point to Point Method End of Line Method Load Centering MethodCIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITSPercentage DropTotals Totals Totals Nominal System Voltage: End of Line VoltageCircuit Number as noted on drawings:ABPart Number Candela.150 = 150 maMinimum Device Voltage: Total Circuit Current: Total Amp Per CktVOLTAGE DROP CALCULATIONSDistance from source to 1st device:Standby:Alarm:Spare CapacityWire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device in any method must not be lower than the manufacturers listed minimum operating voltage (IE: rated operating voltage 20-32 VDC).End of Line and Load Centering Methods use only the wire guage for the first device to sourceStandard Wire Resistance in Ohms per 1000 feet.Wire Gauge for balance of circuit:Enter current in ampsVoltageEnd of Line Voltage End of Line Voltage End of Line VoltagePercent Drop Percentage DropMinimum SpareCapacity RequiredCurrent DrawCapacity UsedCapacity (Notincluding Spare) Project #:13499Date:Panel Label:FACP1.5AmpsVoltage Voltage Voltage20.4AmpsCurrent Distance Drop Current Distance Drop Current Distance Drop16Amps65 65 65Amps20.4020.4020.4065Ft Wire Ohm's24Hours0.0166Gauge Per 100010Minutes0.16614 2.52514 2.525 18=6.385 16=4.01614=2.52512=1.59 10=0.99Distance18-14 Awg = Solid Conductors 12-10 Awg = Stranded ConductorsfromNotes:DeviceDevice previous At Drop from PercentNumberCurrent device Device source DropNone 65 20.40None 20.40None 20.40None 20.40None 20.40None 20.40 Minimum Spare Capacity Required20%0.20None 20.40Current Draw Capacity UsedNone 20.40Capacity (Not including Spare) 80%0.20None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40Totals: 65 20.40CIRCUIT IS WITHIN LIMITSProject Name: CCCC AUTO RESTORATION 1/17/2018Calculations provided by Tritek Fire & SecurityModel #:NFW2-100Location of Circuit:Point to Point Method End of Line Method Load Centering MethodCIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITSPercentage DropTotals Totals Totals Nominal System Voltage: End of Line VoltageCircuit Number as noted on drawings:ACPart Number Candela.150 = 150 maMinimum Device Voltage: Total Circuit Current: Total Amp Per CktVOLTAGE DROP CALCULATIONSDistance from source to 1st device:Standby:Alarm:Spare CapacityWire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device in any method must not be lower than the manufacturers listed minimum operating voltage (IE: rated operating voltage 20-32 VDC).End of Line and Load Centering Methods use only the wire guage for the first device to sourceStandard Wire Resistance in Ohms per 1000 feet.Wire Gauge for balance of circuit:Enter current in ampsVoltageEnd of Line Voltage End of Line Voltage End of Line VoltagePercent Drop Percentage DropMinimum SpareCapacity RequiredCurrent DrawCapacity UsedCapacity (Notincluding Spare) Project #:13499Date:Panel Label:FACP1.5AmpsVoltage Voltage Voltage20.4AmpsCurrent Distance Drop Current Distance Drop Current Distance Drop16Amps50 50 50Amps20.4020.4020.4050Ft Wire Ohm's24Hours0.0166Gauge Per 100010Minutes0.16614 2.52514 2.525 18=6.385 16=4.01614=2.52512=1.59 10=0.99Distance18-14 Awg = Solid Conductors 12-10 Awg = Stranded ConductorsfromNotes:DeviceDevice previous At Drop from PercentNumberCurrent device Device source DropNone 50 20.40None 20.40None 20.40None 20.40None 20.40None 20.40 Minimum Spare Capacity Required20%0.20None 20.40Current Draw Capacity UsedNone 20.40Capacity (Not including Spare) 80%0.20None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40None 20.40Totals: 50 20.40CIRCUIT IS WITHIN LIMITSProject Name: CCCC AUTO RESTORATION 1/17/2018Calculations provided by Tritek Fire & SecurityModel #:NFW2-100Location of Circuit:Point to Point Method End of Line Method Load Centering MethodCIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITSPercentage DropTotals Totals Totals Nominal System Voltage: End of Line VoltageCircuit Number as noted on drawings:ADPart Number Candela.150 = 150 maMinimum Device Voltage: Total Circuit Current: Total Amp Per CktVOLTAGE DROP CALCULATIONSDistance from source to 1st device:Standby:Alarm:Spare CapacityWire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device in any method must not be lower than the manufacturers listed minimum operating voltage (IE: rated operating voltage 20-32 VDC).End of Line and Load Centering Methods use only the wire guage for the first device to sourceStandard Wire Resistance in Ohms per 1000 feet.Wire Gauge for balance of circuit:Enter current in ampsVoltageEnd of Line Voltage End of Line Voltage End of Line VoltagePercent Drop Percentage DropMinimum SpareCapacity RequiredCurrent DrawCapacity UsedCapacity (Notincluding Spare) Project #:13499Date:Panel Label:FACPStandby Hours:24 10Device TypeSTANDBY CURRENT PER UNIT (AMPS)QTYTOTAL STANDBY CURRENT PER ITEMALARM CURRENT PER UNIT (AMPS)QTYTOTAL ALARM CURRENT PER ITEMEOL 4.7K10.0000x2=0.00000.0109x2=0.0218GEC3-24WW1100.0000x7=0.00000.1890x7=1.3230GES3-24WW150.0000x5=0.00000.0420x5=0.2100GEC3-24WW300.0000x2=0.00000.0860x2=0.1720GES3-24WW300.0000x1=0.00000.0580x1=0.0580GEC3-24WW600.0000x2=0.00000.1250x2=0.2500GEC3-24WW150.0000x1=0.00000.0700x1=0.070000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.000000.0000x0=0.00000.0000x0=0.0000NFW2-1000.3000x1=0.30000.3250x1=0.3250REQUIRED STANDBY TIME (HRS) NFPA 72TOTAL SYSTEM STANDBY CURRENT (AMPS)REQUIRED STANDBY CAPACITY (AMP-HOURS)REQUIRED ALARM TIME (HOURS) NFPA 72TOTAL SYSTEM ALARM CURRENT (AMPS)REQUIRED ALARM CAPACITY (AMP-HOURS)24x0.3000=7.20000.166x2.4298=0.4033REQUIRED STANDBY CAPACITY (AMP-HOURS)REQUIRED ALARM CAPACITY (AMP-HOURS)SAFETY FACTORADJUSTED BATTERY CAPACITY (AMP-HOURS)7.20+0.4033=x120%=9.12412AHBATTERY SUPPLIED FOR PROJECTTOTAL CAPACITY (AMP-HOURS)7.60330.3000TOTAL SYSTEMALARM CURRENT (AMPS) 2.4298TOTAL SYSTEMSTANDBY CURRENT (AMPS)Alarm Minutes:NAC PANEL BATTERY CALCULATIONSProject Name:CCCC AUTO RESTORATION 1/17/2018Calculations provided by Tritek Fire & Security