HomeMy WebLinkAboutClovelly_CUP Submittal Package_05-09-16 via EmailJOHN TYLER JOHNSON JR
0660-75-5707.000
STEPHEN B GAINEY
0660-85-4983.000
BETSY S WARREN
0660-86-3334.000
SPENCER TRENT NEWTON
0660-86-2816.000
SPENCER TRENT NEWTON
0660-87-1263.000
SPENCER TRENT NEWTON
0660-87-0464.000
GRADY S NEWTON
0660-68-6104.000
JOHN TYLER JOHNSON JR
0660-75-5707.000
JOHN TYLER JOHNSON JR
0660-75-5707.000
N
E
I
L
'
S
C
R
E
E
K
R
D
PROPOSED POINT OF INTERCONNECTION
SOLAR ARRAY AREA
INCLUDING ALL
EQUIPMENT
35' FRONT SETBACK
30' SITE ACCESS WITH
96' TURN AROUND
25' SIDE SETBACK
25' SIDE SETBACK
25' REAR SETBACK
EXISTING PARCELS TO
BE COMBINED UPON
ZONING APPROVAL
25' SIDE SETBACK
30' TYPE B BUFFER (TYP.)
EXISTING VEGETATION TO BE
UTILIZED WHERE POSSIBLE
EXISTING VEGETATION TO BE
UTILIZED WHERE POSSIBLE
NORTH
N
GRAPHIC SCALE
100'0 100'
1" = 100'
PIN #PROPERTY OWNER SITE ADDRESS
0660-77-2173.000 DOROTHY B PAGE NEILL'S CREEK RD
0660-76-3960.000 DWIGHT P CARSON LILLINGTON, NC 27546
0660-76-3657.000 DWIGHT P CARSON
0660-76-3176.000 LEWIS D JOHNSON JR, LEWIS JOHNATHON MURRAY
ZONING JURISDICTION ZONING CURRENT LAND USE
HARNETT COUNTY RA-20 M AG
PRELIMINARYPRELIMINARY PARCEL
PROPOSED USE DISTURBED AREA SOLAR AREA ACREAGE
SOLAR ENERGY SYSTEM ± 41 AC ± 39 AC ± 29.19 AC
± 1.75 AC
*PRELIMINARY ARE SUBJECT TO CHANGE ± 1.85 AC
± 23 AC
PARCEL LINE SETBACKS REQUIRED
MIN. FRONT YARD 35 FT
MIN. SIDE YARD 25 FT
MIN. REAR YARD 25 FT
SITE DATA
1.THE PURPOSE OF THIS PLAN IS FOR ZONING REVIEW AND APPROVAL BY HARNETT
COUNTY, NC TO CONSTRUCT A SOLAR ENERGY SYSTEM.
2.THIS PLAN WAS PRODUCED UTILIZING GIS RESOURCES AND INFORMATION FROM
MULTIPLE SOURCES, INCLUDING HARNETT COUNTY GIS, GOOGLE EARTH, AND BING
IMAGERY.
3.A PORTION OF THE SUBJECT PROPERTY DOES NOT LIE WITHIN A SPECIAL FLOOD
HAZARD AS SHOWN ON THE FLOOD INSURANCE RATE MAP (COMMUNITY PANEL
3720066000J, DATED 10-03-2006) PUBLISHED BY THE FEDERAL EMERGENCY
MANAGEMENT AGENCY (FEMA).
4.THE LOCATIONS OF PROPOSED IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO:
FENCING, SOLAR ARRAY RACKING, INVERTER/TRANSFORMER PADS, OVERHEAD POLES
AND LINES, ETC., SHOWN ARE APPROXIMATE AND ARE SUBJECT TO MODIFICATION DUE
TO SITE CONDITIONS, ADDITIONAL PERMITTING REQUIREMENTS, EQUIPMENT
SPECIFICATIONS, AND/OR OTHER CONSTRAINTS.
5.PROJECT AREA, INCLUDING CONSTRUCTION STAGING AREAS, WILL BE CLEARED AND
GRUBBED AS NECESSARY, RETAINING PRE-DEVELOPMENT DRAINAGE PATTERNS TO
THE BEST EXTENT POSSIBLE. CONSTRUCTION STAGING AND AREAS SUBJECT TO
RUTTING DURING CONSTRUCTION WILL BE TEMPORARILY STABILIZED WITH GRAVEL.
SOIL CONDITIONS AND EQUIPMENT LOADS WILL DETERMINE FINAL DESIGN.
6.ALL DIMENSIONS SHOWN ARE AT 90 DEGRESS UNLESS OTHERWISE NOTED.
7.CONTRACTOR SHALL CALL AT LEAST 72 HOURS PRIOR TO BEGINNING CONSTRUCTION
OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. ADDITIONLLY, CONTRACTOR
SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES.
8.CONTRACTOR SHALL MAINTAIN ACCESS AND UTILITY SERVICES TO ANY REMAINING
BUILDING(S) OR ADJACENT BUILDING(S) THROUGHOUT THE DEMOLITION AND
CONSTRUCTION PHASES. EXISTING IMPROVEMENTS DAMAGED DURING
CONSTRUCTION SHALL BE REPLACED/RESTORED TO THE SATISFACTION OF THE
OWNER BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE.
9.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE TO PROVIDE SIGNS, BARRICADES,
WARNING LIGHTS, GUARD RAILS, AND EMPLOY FLAGGERS AS NECESSARY WHEN
CONSTRUCTION ENDANGERS EITHER VEHICULAR OR PEDESTRIAN TRAFFIC. THESE
DEVICES SHALL REMAIN IN PLACE UNTIL THE TRAFFIC MAY PROCEED NORMALLY
AGAIN.
10.THE ZONING SITE PLAN IS SUBJECT TO MINOR REVISIONS TO BE APPROVED BY
JURISDICTION'S BUILDING DEPARTMENT.
GENERAL NOTES
VICINITY MAP
SCALE 1" = 5000'
N
LENGTH
VARIES
PER
DESIGN
PV MODULES
POST SPACING
VARIES
FRONT ELEVATION
TYPICAL RACK ELEVATION DETAIL
(NOT TO SCALE)
PV MODULES
2'-7"
MAX HEIGHT 12'
22'-3" ROW SPACING MAY VARY
CROSS SECTION
TYPICAL RACK SECTION DETAIL
(NOT TO SCALE)
LEGEND
EXISTING CONDITIONS
BUILDING SETBACK
EDGE OF PAVEMENT
OVERHEAD
ELECTRICAL
STRUCTURES
TREELINE
PROPERTY LINES
STREET CENTERLINE
PROPOSED CONDITIONS
PROJECT AREA
SECURITY FENCE
SITE ACCESS
TREELINE
VEGETATIVE BUFFER
SEAL
PROJECT
CY
P
R
E
S
S
C
R
E
E
K
RE
N
E
W
A
B
L
E
S
32
5
0
O
C
E
A
N
P
A
R
K
B
L
V
D
:
:
S
U
I
T
E
3
5
5
:
:
S
A
N
T
A
M
O
N
I
C
A
,
C
A
9
0
4
0
5
RE
V
I
S
I
O
N
S
DA
T
E
DE
S
C
R
I
P
T
I
O
N
RE
V
5432
A
B
C
D
1 6 7 8 90
54321 6 7 8 90
A
B
C
D
E
F
G
E
F
G
H
10
10
A
B
C
D
E
F
G
H
CONSULTANT
NE
I
L
L
'
S
C
R
E
E
K
R
D
LI
L
I
N
G
T
O
N
,
N
C
2
7
5
4
6
CL
O
V
E
L
L
Y
S
O
L
A
R
,
L
L
C
CHECKED BY:
DRAWN BY:
DATE:05-09-16
XXX
G 0.0
JLS
ZONING
SITE PLAN