Loading...
HomeMy WebLinkAbout2013.03.12 Village Part 6ENGINEERING STAFF REPORT Harnett County, North Carolina 102 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7555 Fax: (910) 814-2662 Development Name: Village of Lexington Part 6 Preliminary Plat Property Description PIN(s):   Acreage:  Acres  Address/SR No.: Centennial Parkway   # of Lots:   Developer: Lexington Plantation   Plan/Plat Review Correct Incorrect N/A  TITLE BLOCK INFORMATION  Name of Project & Date (Including all Revision Dates)     Applicant/Owner(s) Contact Information (Name, Address, & Phone)     Surveyor/Engineer Contact Information (Name, Address, & Phone)     Parcel ID Number/Tax ID of Tract(s)     Deed Reference of Tract(s)     Location (Including Township, County, & State)     Flood Plain Depicted & Noted (Zone, Map Number, & Effective Date)     Watershed District Noted & Extent of Coverage Depicted     Impe rvious Area Percentage Noted Including Proposed Improvements     GENERAL REQUIREMENTS  Map Size 18” X 24” & Scale 1”=200’ or Larger     North Point, Graphic Scale, & Vicinity Map     Name(s) & Location(s) of Adjacent Property Owner(s) & Use(s)     Existing Boundaries of Tract(s) Showing Bearings & Distances     Gross Acreage of Development     Name(s) & Right(s)-of-way of Streets & State Road Number(s), Including Notation of Public or Private     Name, Location, Width, & Acreage of Additional Easement(s) & Right(s)-of-way Within or Adjacent to Site     Wetlands Delineated     All water features as found on USGS Quadrangles and the Harnett County Soil Survey     Req uired riparian buffers/setbacks around each water feature     Easements, including drainage and utility, Open Space, & Areas Other Than for Residential Use with Explanation of Purpose & Maintenance Responsibility     The 100-year flood plain boundaries and elevations from the most recent FIRM.     Disturbed Acreage     Master Plan     Predev elopment Conference     PRELIMINARY PLAT ONLY     Total Number of Lots Proposed     Linear Feet per Street (Note Either Public or Private)     Topography (Max Contour Levels of 5’)      Stormwater Management Statement     Conceptual Plan     CONSTRUCTION PLAN/DRAWING REVIEW  A copy of the erosion control plan submitted to the appropriate authority, if such a plan is required.     A copy of the stormwater plan submitted to the appropriate authority, if such a plan is required.     Erosion Control Measures and Details      Detailed topographic information. A minimum 2 foot contours is required. Vertical datum provided.     Storm sewer profiles or design tables indicating the top of structure, invert elevations, and pipe slope.     All proposed stormwater management facilities.     Construction details for improvements     Drainage easements     Utility easements     FINAL PLAT ONLY  Total Number of Lots Proposed     Stormwater Certification     As-built Drawings     SITE PLAN ONLY  Topography (Max Contour Levels of 5’)     Erosion Control Plan Submitted     Impervious Surface (% Coverage of Lot)     Existing & Proposed Utility Areas     Stormwater Easements Obtained     Stormwater Management Statement     Conceptual Plan     REQUIRED INSPECTION     Drainage Easements are Stabilized Without Possible Erosion      Ballot REVIEWER:Amanda Bader Date: 3/12/13      VOTE: Conditionally Approve CONDITIONS: SHORT TERM: It is our understanding that the low density option will be pursued. Need a copy of letter from DENR for this option. LONG RANGE: A copy of the erosion control plan.    Erosion Control Measures and Details  Detailed topographic information. A minimum 2 foot contours is required. Vertical datum provided.  Storm sewer profiles or design tables indicating the top of structure, invert elevations, and pipe slope.  All proposed stormwater management facilities.  Construction details for improvements