Loading...
HomeMy WebLinkAbout2013.03.12 Anderson Creek Park - EngineeringENGINEERING STAFF REPORT Harnett County, North Carolina 102 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7555 Fax: (910) 814-2662 Development Name: Anderson Creek Park – Phase 1 PIN(s): 0516-19-1156  Acreage:  acres  Address/SR No.:   Deed Reference(s):         Township:      Developer:    Plan/Plat Review Correct Incorrect N/A  TITLE BLOCK INFORMATION  Name of Project & Date (Including all Revision Dates)     Applicant/Owner(s) Contact Information (Name, Address, & Phone)     Surveyor/Engineer Contact Information (Name, Address, & Phone)     Parcel ID Number/Tax ID of Tract(s)     Deed Reference of Tract(s)     Zoning Classification of Tract(s)     Location (Including Township, County, & State)     Flood Plain Depicted & Noted (Zone, Map Number, & Effective Date)     Watershed District Noted & Extent of Coverage Depicted     Impe rvious Area Percentage Noted Including Proposed Improvements     GENERAL REQUIREMENTS  Map Size 18” X 24” & Scale 1”=200’ or Larger     North Point, Graphic Scale, & Vicinity Map     Gross Acreage of Development     Existing & Proposed Utilities     Wetlands Delineated     All water features as found on USGS Quadrangles and the Harnett County Soil Survey     Required riparian buffers/setbacks around each water feature     Easements, including drainage and utility, Open Space, & Areas Other Than for Residential Use with Explanation of Purpose & Maintenance Responsibility     The 100-year flood plain boundaries and elevations from the most recent FIRM.     Disturbed Acreage     Master Plan     Predevelopment Conference     PRELIMINARY PLAT ONLY     Total Number of Lots Proposed     Topography (Max Contour Levels of 5’)     Stormwater Management Statement     Conceptual Plan     CONSTRUCTION PLAN/DRAWING REVIEW  A copy of the erosion control plan submitted to the appropriate authority, if such a plan is required.     A copy of the stormwater plan submitted to the appropriate authority, if such a plan is required.     Erosion Control Measures and Details      Detailed topographic information. A minimum 2 foot contours is required. Vertical datum provided.     Storm sewer profiles or design tables indicating the top of structure, invert elevations, and pipe slope.     All proposed stormwater management facilities.     Construction details for improvements     Drainage easements     Utility easements     FINAL PLAT ONLY  Total Number of Lots Proposed     Stormwater Pond Certification     Stormwater Certification Stamp     As-built Drawings – Electronic pdf     SITE PLAN ONLY  Topography (Max Contour Levels of 5’)     Erosion Control Plan Submitted     Impervious Surface (% Coverage of Lot)     Stormwat er Management Statement     Conceptual Plan     REQUIRED INSPECTION  Drainage Easements are Stabilized Without Possible Erosion      Ballot REVIEWER: Bader Date: 3/12/13 VOTE: Conditionally Approve CONDITIONS: SHORT TERM: Submit erosion control approval. LONGE RANGE: