Loading...
HomeMy WebLinkAboutDecision Packet Phase A 1A #2 DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: GATE @ LEXINGTON PHASE A PART 1A Development Type: Major Subdivision Final Plan/Plat Date: DECEMBER 17, 2008 The above referenced application shall be HELD for further revision and review. SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. Fire Marshal (910)893-7580: Install temporary turn arounds at end of Regimental Dr, end of  Conditionally Approve: Marquis Dr. Crutchfield Drive shall either be connected to Richmond Park or have a temporary turn around installed. E911/Addressing (910)814-2038: Need corrections to plat and vicinity map. Contact 910-814-  Conditionally Approve: 6372. Centennial Parkway must be recorded as a dedicated Right of  Way Will the drainage pipe behind lots 117&118 be in an open  Planning Department (910)893-7525: ditch? If so, ditch should be adequately stabilized and Conditionally Approve: reinforced…rip-rap, etc. Lot 128 encroaches into wetlands. Please show entire bldg  envelope to ensure that these are buildable lots and to ensure the structure will not encroach into the wetland. Edge of Pavement is not extended enough to provide  adequate lot frontage on lots 230 & 231…corner lots. Provide HCDPU with an updated Master development Plan to  Public Utilities (910)893-7575: show all proposed roads, streets, phases, phase lines and Hold: proposed lots with lot numbers in each phase. The Harnett County Fire Marshal must approve the fire  hydrant layout before the utility plans can be approved by HCDPU. The water and sewer improvements must be permitted with  NCDENR and approved by HCDPU and NCDENR before these systems can be installed, certified, approved and placed into operation. The P.E. must submit utility plans, an engineer's report, project specifications along with the water and sewer permit applications for review and subsequent approval by HCDPU. Environmental Health (910)893-7547: Approve: LONG RANGE CONDITIONS The following conditions must be satisfied Must meet all requirements set forth by NC DENR. Contact at (910)433-3300. Decision Packet Phase A 1A #2 4/6/2009 1 The developer must provide HCDPU with a one (1) year  Public Utilities (910)893-7575: warranty on the water and sewer system improvements installed to served this subdivision. : : : : Development Review Board Chairman If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2) business days. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait, as all DRB members will have to review the plat/plan for compliance. If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Wednesday following the meeting the application was put on hold. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options. Decision Packet Phase A 1A #2 4/6/2009 2