HomeMy WebLinkAboutRICHMOND PARK SECT 6 DECISION
DRB DECISION PACKET
Harnett County, North Carolina
Planning Department
108 E. Front Street, Lillington, NC 27546
Phone: (910) 893-7525 Fax: (910) 893-2793
Development Name: RICHMOND PARK SECTION 6
Development Type: Major Subdivision Preliminary Plan/Plat
Date: Sep. 12, 2007
The above referenced application
shall be HELD for further revision and review.
SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS
The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the
meeting.
Fire Marshal (910)893-7580: Fire hydrants to be placed on the right side of the road
Conditionally Approve:
The following existing street names should be shown on the
E911/Addressing (910)814-2038:
plat: Providence Ct, Plantation Dr, Arlington Dr, Crutchfield
Conditionally Approve:
Dr
Hayden Ln should be shown on the street and not in the lot
area
Hawthorne St is denied. 2 street names are needed for this
Berkleys Way is not on list of approved names
Streets should not be shaded in
Project location should be listed as NC 24-87/Plantation Dr
Remove 'Planned Unit Development' note; this project has not
Planning Department (910)893-7525:
been granted a conditional use permit for a planned unit
Hold:
development
Lot numbers must continue from last numbered lot in
subdivision
Identify both Phase and Section for this application
(Preliminary plat for Phase 3 shows this portion of site; so it's
not included in Phase 3). The next Phase for this development
should be Phase 6
Vicinity map is insufficient
Identify adjacent Phases & Sections of Richmond Park
All streets shown on plat must be named, noted as public, SR
number (if applicable), and right-of-way width
Open space is noted but no open space is shown on plat;
either remove notes or show open space; if wetlands are to
be open space, lot lines must be adjusted to show such and
easements must be provided for access; acreage data and
open space maintenance note must be adjusted accordingly
30' front setback note must be removed
Patio home lot typical must be removed
Points of measurement must be shown for curves to verify lot
widths; all lots with curves cannot be verified without this
data
Street lights must be installed every 300 ft. (currently there
RICHMOND PARK SECT 6 DECISION
3/30/2009
1
are not enough lights shown)
Deed reference must be noted
Must connect to existing Richmond Park Dr. (SR 2412)
Environmental Health (910)893-7547:
Approve:
The Developer must hire a PE to design the water and sewer
Public Utilities (910)893-7575:
lines to serve the residential lots in this development. The
Conditionally Approve:
sewer capacity for this development may be limited due to
adjacent development and the limited capacity at Harnett
County's existing WWTP. This project may need to be placed
on Hold pending the availability of additional sewer capacity
at the new South Harnett Regional WWTP to begin
construction in 2007. If approved, the lots will not be
provided water meters until HCDPU can verify the sewer
capacity is available and Harnett County reserves the right to
limit the release of water meters accordingly.
LONG RANGE CONDITIONS
The following conditions must be satisfied
NOTE: Future plats submitted without prior street name approval will be
E911/Addressing (910)814-2038:
placed on hold. Subdivision/Road Name Requests are recommended to be submitted no later than 5 days
prior to DRB Application Deadline.
The developer and the PE should obtain a letter of sewer capacity for this
Public Utilities (910)893-7575:
development before the preliminary plat may be approved for the proposed 52 residential lots in the
Richmond Park - Section 6 subdivision.
:
:
:
:
Development Review Board
Chairman
If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2)
business days.
If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all
items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait,
as all DRB members will have to review the plat/plan for compliance.
If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been
rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Friday following the meeting
the application was put on hold.
If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with
Planning Staff to discuss other potential options.
RICHMOND PARK SECT 6 DECISION
3/30/2009
2