Loading...
HomeMy WebLinkAboutStonecross Sec. II- SR Public Utilities 03 PUBLIC UTILITIES STAFF REPORT Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: Stone Cross - Phase 2 Section 2 - Preliminary Plan/Plat Property Description PIN(s): 0515-30-4536.000 Acreage: 15.00 acres Address/SR No.: Stone Cross Drive and Cobblestone Drive (off of Overhills Road SR 1120) Water Public water is available for this development (via Harnett County) Water capacity is available for this development Nearest water line location (Road name & SR#): Nearest water line size: 6" water line is on Stone Cross Drive and Cobblestone Drive which should be adequate to provide water to this development. Notes: • Road grades were not established for the Utility Contractor in Phase 2 Section 1 and the water lines were installed. The water lines ended up under the pavement as a result of the road not being pproperly staked out from the beginning of the project. • Water lines in Phase 2 Section 1 were installed without the NCDENR permit or HCDPU approval. The NCDENR permit was eventually acquired and then certified by the P.E. • As-Built Record Drawings for Phase 2 section 1 were never provided to HCDPU as promised. These record drawings must be provided to HCDPU in paper, mylar and digital formats for Phase 2 Section 1 before the preliminary plat for Phase 2 Section 2 will be approved by HCDPU. • A two (2) year warranty must be provided to HCDPU for the water lines in Phase 2 Section 1 and the warranty period shall begin once the As-Built Record Drawings for Phase 2 section 1 have been submitted to HCDPU. The As-Built Record Drawings have not been received by HCDPU as of October 22, 2007 at 5:00 pm. • NCDENR permit for new water lines must be issued for the Phase 2 Section 2 before construction may begin. • Fire hydrants in Phase 2 Section 1 were not installed to finish grade and these fire hydrants must be re-positioned to finish grade before the preliminary plat will be approved by HCDPU. The fire hydrants have been re-positioned to finish grade as required. • The utility contrator did not have a pre-construction meeting with HCDPU for Phase 2 Section 1 and the utility contractor must provide HCDPU with material submittal package at the pre-construction meeting for Phase 2 Section 2 or the project permit will be rescinded with NCDENR by HCDPU and the development will be issued a STOP WORK ORDER. Fire flow is available for this development Lines permitted under DENR Permit: 05-01695 (DEH Serial Number) Page 1 of 2 PUBLIC UTILITIES STAFF REPORT Sewer Public sewer is not available for this development (via Harnett County) Sewer capacity is not available for this development Nearest sewer line location (Road name & SR#): Overhills Road (SR 1120) and Ray Road (SR 1121) which is more than 1,700 feet (17 lots x 100 ft/lot) from the project site. Nearest sewer line size: 8” Lines permitted under DENR Permit: (DWQ Serial Number) Additional Requirements As-Built Record Drawings Yes No N/A Cost Statement for water improvements Yes No N/A Cost Statement for sewer improvements Yes No N/A Professional Engineer’s Certifications for water/sewer extension Yes No N/A Final Plat & As-Built Record Drawings are identical Yes No N/A DOT Encroachment Agreement Yes No N/A Distance to nearest water/sewer lines noted (Site Plan Only) Yes No N/A Master Plan submitted for additional phases if intended Yes No N/A Ballot REVIEWER: Tim Payseur Date: Oct. 24, 2007 VOTE: Hold CONDITIONS: SHORT TERM: • Accurate As-Built Record Drawings for Phase 2 Section 1 of the Stone Cross subdivision must be submitted to HCDPU in paper, mylar and digital formats. • The developer must provide HCDPU with a two (2) year warranty on the water lines in Phase 2 Section 1 to begin once the As-Built Record Drawings for Phase 2 Section 1 have been submitted to HCDPU. • A Master Development Plan should be submitted to HCDPU for the entire development of the Stone Cross subdivision. LONG RANGE: Please visit www.harnett.org/utilities for more information on the approval process.  The Developer must follow the established approval process for the proposed water lines that  will serve this subdivision. Page 2 of 2 PUBLIC UTILITIES STAFF REPORT