Loading...
HomeMy WebLinkAboutGABLES DECISION 2 leg out from under the pavement. The Developer must hire a licensed Utility Contractor to  install water and sewer lines to serve the residential lots in this development in accordance with the approval process of HCDPU. Environmental Health (910)893-7547: Approve: LONG RANGE CONDITIONS The following conditions must be satisfied Front tract must be recombined with large tract prior to  Planning Department (910)893-7525: submittal of final plat HOA documents must be submitted prior to final plat approval NOTE: Future plats submitted without prior street name approval will be E911/Addressing (910)814-2038: placed on hold. Subdivision/Road Name Requests are recommended to be submitted no later than 5 days prior to DRB Application Deadline. Please visit www.harnett.org/utilities for more information on the  Public Utilities (910)893-7575: approval process. : : : Development Review Board Chairman If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2) business days. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait, as all DRB members will have to review the plat/plan for compliance. If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Friday following the meeting the application was put on hold. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options. GABLES DECISION 2 3/30/2009 2 DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: THE GABLES Development Type: Major Subdivision Preliminary Plan/Plat Date: Oct. 24, 2007 The above referenced application is CONDITIONALLY APPROVED as listed below. SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. Fire Marshal (910)893-7580: Approve: Gadsen Ln should be 2 streets; Royal Palm St and Gadsen Ln  E911/Addressing (910)814-2038: SITE DATA: Property address should be NC 24-27, not NS  Conditionally Approve: 24-27 VICINITY MAP: Harnett Rd should be Needmore Rd  Townsend Ct was not approved, please request another road name Open space at rear of property must be one contiguous lot  Planning Department (910)893-7525: (remove hard line and "access easement" note and Conditionally Approve: recalculate acreage) Open space (prime views and vistas) at front of property  should be noted as such and acreage provided for each portion "100' Buffer" should read "100' Prime Views & Vistas Setback"  PIN for front tract must be included  Land Use must be noted  Note "concrete" on curb detail  Correct property address in Site Data  Total acreage should be labeled at such in Site Data, not as  "Lot Area" Remove "FIRMID" from Site Data  Correct spelling of responsible in Note 3  Lot 95 side setback must be 20'  Lots 61 & 63 do not meet minimum lot width  Cannot verify width on Lot 65  Density must be noted  Impervious surface limit (24%) must be noted  Show topo's for entire site  Foundation survey requirement must be noted The Developer must hire a PE to design the water lines to  Public Utilities (910)893-7575: serve the residential lots in this development in accordance Conditionally Approve: with the approval process of HCDPU. The water lines must be permitted with NCDENR and certified by the P.E. The proposed water line on Gadsen Lane (West) should be  moved to the right side of the road to keep the fire hydrant GABLES DECISION 2 3/30/2009 1