Loading...
HomeMy WebLinkAboutPU-SR-01 Ballot REVIEWER: Tim Payseur Date: Aug. 22, 2007 VOTE: Hold CONDITIONS: SHORT TERM: This subdivision will be served by a 4" water line and septic tanks as county sewer is not  available to this site. The water line has been permitted with NCDENR - Division of Environmental Health, Public Water Supply Section under DEH Serial # 07-02130. The final inspection has been completed but, the As-Built Record Drawings and the PE Certification have not been provided to HCDPU by the Professional Engineer. The developer has not provided the Cost Statement for the water system improvements to  HCDPU. LONGE RANGE: Please visit www.harnett.org/utilities for more information on the approval process.  The Developer must provide HCDPU with a one (1) year warranty on the water system  improvements installed to serve this development. Page 2 of 2PUBLIC UTILITIES STAFF REPORT PUBLIC UTILITIES STAFF REPORT Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: Cinnamon Hill Subdivision -Final Property Description PIN(s): 9691-48-6636.000 Acreage: 8.56 acres Address/SR No.: Lawrence Road (SR1272) Water Public water is available for this development (via Harnett County) Water capacity is available for this development Nearest water line location (Road name & SR#): Holly Springs Church Road (SR 1273) Nearest water line size: 4" NOTE: Harnett County has an existing four (4") inch water distribution line located on the north side of Lawrence Road (SR 1272) that can provide domestic (potable) drinking water only. This four (4") inch water main cannot support fire flow for fire hydrants or fire protection for this proposed subdivision. The Harnett County Fire Marshal must provide a written variance for this subdivision to be served by a four (4") inch water line without fire hydrants or the subdivision must be reduced to six (6) lots or less which would be classified as a minor subdivision. The written variance was not provided to HCDPU in the preliminary plat/plan approval. NOTE: HCDPU provides this information as a curteousy to the developer and professional engineer for design purposes. However, HCDPU cannot be held liable for errors, mistakes, ommissions, and inaccurate information provided through this preliminary and/or final plat approval process. It is therefore recommended that the professional engineer or developer "field verify" the information provided by HCDPU. Fire flow is available for this development Lines permitted under DENR Permit: (DEH Serial Number) Sewer Public sewer is not available for this development (via Harnett County) Sewer capacity is not available for this development Nearest sewer line location (Road name & SR#): Nearest sewer line size: Lines permitted under DENR Permit: (DWQ Serial Number) Additional Requirements As-Built Record Drawings Yes No N/A Cost Statement for water improvements Yes No N/A Cost Statement for sewer improvements Yes No N/A Professional Engineer’s Certifications for water/sewer extension Yes No N/A Final Plat & As-Built Record Drawings are identical Yes No N/A DOT Encroachment Agreement Yes No N/A Distance to nearest water/sewer lines noted (Site Plan Only) Yes No N/A Master Plan submitted for additional phases if intended Yes No N/A Page 1 of 2PUBLIC UTILITIES STAFF REPORT