Loading...
HomeMy WebLinkAboutTINGEN POINTE DECISION •Lot width cannot be verified on several lots due to incomplete curve and line tables •Verification of road sign purchase must be provided •Acreage for each open space area must be noted •Streetscape buffer must be installed prior to expiration of letter of credit •INSPECTION: Gas containers must be removed from Lots 16 & 19 •INSPECTION: Pavement must continue to end of development (Lots 70 & 71) Public Utilities (910)893-7575: Once the fire hydrants have been adjusted as outline in Item # 1 above, the P.E. must provide HCDPU revised As-Built Record Drawings (mylar & digital formats) to HCDPU before the final plat may be released for recordation with the Harnett County Register of Deeds. HCDPU and the P.E. have submitted the final certifications to NCDENR - PWSS to obtain the Final Approval for the new water line(s) installed to serve this subdivision. HCDPU may release water meters for the lots of this new subdivision once the NCDENR - PWSS Final Approval has been issued to HCDPU, the E-911 addresses have been assigned to the lots and the Developer has paid the Capacity Use Fees. : LONG RANGE CONDITIONS The following conditions must be satisfied Planning Department (910)893-7525: Must meet all requirements of NC DENR- (910)433-3300 Public Utilities (910)893-7575: The Developer and Contractor must provide HCDPU with a one (1) year warranty on the new water mains and sewer collection lines and associated appurtenances that serve this project once the new utility improvements have been approved by HCDPU and NCDENR. : : : Development Review Board Chairman If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2) business days. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait, as all DRB members will have to review the plat/plan for compliance. If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Friday following the meeting the application was put on hold. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options. TINGEN POINTE DECISION 3/25/2009 2 DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: TINGEN POINTE Development Type: Major Subdivision Final Plan/Plat Date: Jul. 25, 2007 The above referenced application is CONDITIONALLY APPROVED as listed below. SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. Fire Marshal (910)893-7580: Fire hydrant spacing on Juno Dr exceeds the distance between fire hydrants, install new hydrant between or move the existing hydrant E911/Addressing (910)893-7566: Vicinity Maps/All Maps Sheets 1-7: NC HIGHWAY 27 WEST should be listed as NC 27 W Sheet 1 of 7: NC HIGHWAY 27 should be listed as NC 27 W Sheet 1 of 7: Map Sheet Notes # 7: NC HIGHWAY 27 should read NC 27 W Sheet 2 of 7: NC HIGHWAY 27 (60' PUBLIC R/W) should be listed as NC 27 W Sheet 4 of 7: Please indicate Sword Loop Sheet 5 of 7: Please indicate Juno Dr THE ROAD SIGN COST IS $500.00 FOR 4 INTERSECTIONS.PRESENT THIS FORM WITH PAYMENT TO THE PLANNING DEPT BEFORE FINAL DRB APPROVAL. Planning Department (910)893-7525: •Name of Project should include Phases 1, 2, & 3A (as depicted on preliminary plat); ALL notes on plat must be corrected accordingly •Phase lines must be shown on plat •Flood reference must be corrected •Note 10 (RE: ROADS) should reference 75% build out rule for turning streets over to DOT •Note 2 (RE: EXISTING EASEMENTS) must be removed •All existing easements must be shown on plat •Note 4 (RE: EASEMENTS) should read, 'All interior lots shall have a 10' public easement on each side of all lot lines' •Future development cannot be included in total acreage of this portion of development; adjust 'Area Summary' and total acreage accordingly •Explanation of purpose and maintenance requirements for open space must be noted •Curve and Line Tables must be completed; (Not shown: L189, L131-132, C164-165, L42, L174-177, L44, C105, C109-110, C112-116, C166-169, L180, L137-138) TINGEN POINTE DECISION 3/25/2009 1