Loading...
HomeMy WebLinkAboutWALNUT GROVE DECISION PACKET : : : : : Development Review Board Chairman If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2) business days. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait, as all DRB members will have to review the plat/plan for compliance. If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Friday following the meeting the application was put on hold. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options. WALNUT GROVE DECISION PACKET 3/23/2009 2 DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: WALNUT GROVE Development Type: Major Subdivision Preliminary Plan/Plat Date: Sep. 12, 2007 The above referenced application is CONDITIONALLY APPROVED as listed below. SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. Fire Marshal (910)893-7580: . Fire Hydrant to be added near lot # 24 2. Fire hydrant to be moved Conditionally Approve: from lot # 19/18 to the corner or lot # 18 Winged Foot and Sawgrass 3. Fire Hydrant to be added to the entrance at Lasater Rd and Walnut Grove Drive E911/Addressing (910)814-2038: VICINITY MAP: W. Salmon Ln should be listed as W W Salmon Ln Conditionally Approve: Remove flood zone and Watershed note.  Planning Department (910)893-7525: Note or show fire hydrants, as per ordinance.  Conditionally Approve: Lot #14 does not meet minimum lot frontage.  The utility plans have been previously reviewed by HCDPU  Public Utilities (910)893-7575: based upon a different lot layout. Revised utility plans must Conditionally Approve: be submitted to HCDPU for review and subsequent approval based upon the current preliminary plat submitted to the Development Review Board. HCDPU approval of the utilities is contingent upon the Fire  Marshal’s approval of the fire hydrant layout. The developer must provide HCDPU with a Master  Development Plan including the proposed streets, lots and phase lines if future development is planned for this property. Environmental Health (910)893-7547: Soils report needs to be provided Conditionally Approve: LONG RANGE CONDITIONS The following conditions must be satisfied : WALNUT GROVE DECISION PACKET 3/23/2009 1