Loading...
HomeMy WebLinkAboutBLOCK T DECISION PACKET If HELD, you must submit 5 copies of the plat/plan showing that all items listed under Short Term Conditions have been rectified. To attend the next DRB meeting, revised plat/plans must be submitted by noon on Friday following the meeting the application was put on hold. If DENIED, you may appeal the Board’s Decision to the Harnett County Planning Board within 30 days or meet with Planning Staff to discuss other potential options. BLOCK T DECISION PACKET 3/18/2009 3 Show sign easement and note maintenance responsibility  HOA documents must reference maintenance of sign  easement Note installation of street lights and fire hydrants will be in  accordance with Harnett County regulations Drainage easements must be shown and maintenance  responsibility noted unless curb & gutter will be used Street signs must be purchased The Developer must provide HCDPU with a Master  Public Utilities (910)893-7575: Development Plan for any and all additional phases to be Hold: developed in this subdivision in accordance with the approval process of HCDPU. The proposed water lines have been permitted with NCDENR and the permit #06-01645 will expire if construction does not begin before 10-13-2007. The cost estimate certified by Robert J. Bracken, P.E. does  not include cost for water line extensions to serve the subject project. The performance bond must include the cost to install the proposed water lines. The cost estimate certified by Robert J. Bracken, P.E. does  not include cost for a parschal flume and flow meter at the existing lagoon where the proposed force main will discharge. The performance bond must include the cost to install the parschal flume and flow meter. The cost estimate certified by Robert J. Bracken, P.E. does  not include cost for Water Capacity Use Fees, Sewer Capacity Use Fees, Meter Fees, or SCADA Fees that will be required by HCDPU for this proposed subdivision. The performance bond must include the cost to of all applicable fees imposed by HCDPU for this subdivision. Revise the overall Cost Estimate for the improvements to  include all utilities and applicable fees as required by HCDPU. Environmental Health (910)893-7547: Approve: LONG RANGE CONDITIONS The following conditions must be satisfied Please visit www.harnett.org/utilities for more information on the  Public Utilities (910)893-7575: approval process. Planning Department (910)893-7525: Bond good for one year. All improvements must be installed prior to expiration of bond. Development Review Board Chairman If APPROVED, your signed plat/plan may be picked up at the Planning Department or will be mailed to you within two (2) business days. If APPROVED WITH CONDITIONS, you must submit 5 copies of the plat/plan to the Planning Department showing that all items listed under Short Term Conditions have been rectified. Please be aware that review will not be done while you wait, as all DRB members will have to review the plat/plan for compliance. BLOCK T DECISION PACKET 3/18/2009 2 DRB DECISION PACKET Harnett County, North Carolina Planning Department 108 E. Front Street, Lillington, NC 27546 Phone: (910) 893-7525 Fax: (910) 893-2793 Development Name: CAROLINA LAKES BLOCK T Development Type: Major Subdivision Final Plan/Plat Date: Oct. 24, 2007 The above referenced application shall be HELD for further revision and review. SHORT TERM CONDITIONS, COMMENTS, OR JUSTIFICATIONS The following conditions are to be rectified prior to obtaining DRB signature and are subject to change during the course of the meeting. Fire Marshal (910)893-7580: 1. Fire hydrants to be noted on map on prelimenary so they can be Hold: reviewed 2. Temporary turnaround to be located on the following streets: Villa Green, Forest Lane, Spring Forest. When will the future development at the end of these streets be developed? Subdivision/Road Name approval request not received.  E911/Addressing (910)814-2038: Hold: NOTE: Subdivision/Road Name Requests are recommended to be submitted no later than 5 days prior to DRB Application Deadline. Plats submitted without prior street name approval may be placed on hold. Street layout cannot be changed; Forest Ln. to continue to  Planning Department (910)893-7525: Stafford Green as approved on preliminary plat Hold: Installation of street lights and fire hydrants must be included  in estimate and reflected in bond total Naming must be consistent; Should be called 'Phase VIII  Block T (Lakeside Manor)'; All documents and maps MUST show the same name Remove 'Planning Director' stamp from map  Page numbering must begin from cover page (this is the only  place a vicinity map is located and therefore is a necessary part of the submittal) Remove note in title block referencing lots 1-11 & 199-212 on  Cover page and page 2 (these lots are already recorded) Flood boundary must be shown; Zone and effective date must  be noted Show all adjacent property owners and boundaries  Show matchlines on each page  Pump station site- Planning would prefer site recorded as an  easement; If site must be separate lot, must be ONE lot only and noted as 'nonbuildable' and acreage must be shown Note maintenance responsibility on pump station site  Temporary turn around must be shown at end of Forest Ln.  Gross acreage of submittal must be noted  Total number of lots must be noted  Corner lot setback must be noted  Streets must be noted as private  Must have certify (by engineer) that roads will be built to DOT  standards at time of construction BLOCK T DECISION PACKET 3/18/2009 1