Loading...
Revised 10-30-1924,416 SF 0.56 AC Open Space 69,678 SF 1.60 AC Open Space 31,420 SF 0.72 AC 1 28,867 SF 0.66 AC 5 28,009 SF 0.64 AC 39 28,134 SF 0.65 AC 38 28,160 SF 0.65 AC 36 28,058 SF 0.64 AC 37 30,872 SF 0.71 AC 2 21,623 SF 0.50 AC Open Space 29,255 SF 0.67 AC 3 28,676 SF 0.66 AC 4 28,851 SF 0.66 AC 6 28,636 SF 0.66 AC 7 28,015 SF 0.64 AC 16 28,089 SF 0.64 AC 15 28,011 SF 0.64 AC 13 28,096 SF 0.64 AC 10 28,062 SF 0.64 AC 12 28,111 SF 0.65 AC 11 28,035 SF 0.64 AC 8 28,061 SF 0.64 AC 9 28,041 SF 0.64 AC 24 28,087 SF 0.64 AC 23 28,190 SF 0.65 AC 25 28,019 SF 0.64 AC 27 28,007 SF 0.64 AC 22 28,011 SF 0.64 AC 21 28,022 SF 0.64 AC 26 28,046 SF 0.64 AC 31 28,018 SF 0.64 AC 17 28,004 SF 0.64 AC 18 28,030 SF 0.64 AC 30 28,004 SF 0.64 AC 19 28,120 SF 0.65 AC 28 28,071 SF 0.64 AC 29 28,027 SF 0.64 AC 20 34,431 SF 0.79 AC Open Space 29,883 SF 0.69 AC 35 28,075 SF 0.64 AC 32 28,021 SF 0.64 AC 33 39,493 SF 0.91 AC 34 11,094 SF 0.25 AC Open Space 28,008 SF 0.64 AC 14 4,300 SF 0.10 AC Open Space 30,630 SF 0.70 AC Open Space W W W W W W W W W W W W W W W W W W WWWWWWWWWWWWW W W W W W W W W W W W W W W W W W W W Curve Table Curve # C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 Length 37.38 40.62 41.25 37.92 45.34 52.53 39.22 39.45 42.04 36.50 Radius 25.00 25.00 25.00 25.00 275.00 225.00 25.00 25.00 25.00 25.00 Delta 85.68 93.10 94.54 86.90 9.45 13.38 89.89 90.41 96.35 83.65 Chord Direction N55° 04' 33"W N34° 18' 50"E S35° 02' 07"W N55° 41' 10"W N4° 49' 48"E S6° 47' 44"W N45° 03' 13"E S45° 05' 48"E N43° 00' 41"W N46° 59' 19"E Chord Length 34.00 36.30 36.73 34.39 45.29 52.41 35.32 35.48 37.26 33.34 Line Table Line # L1 L2 L3 L4 L5 L6 L7 Length 16.97 23.00 50.18 39.26 16.01 32.04 46.16 Direction S12° 14' 10.00"E N12° 14' 10.00"W S37° 37' 09.71"W S43° 27' 06.63"W N75° 31' 46.94"W N55° 48' 49.96"W N11° 18' 35.76"E Know what's below. before you dig.Call R 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 100 FIRST ISSUEDBYDATEREVISIONS132456CHARLESTON GROVE SUBDIVISIONHARNETT COUNTYPINEY GROVE RAWLS ROADCONSTRUCTION DRAWINGSC3 PROJECT #: 18-034 REVIEW PROJECT #: SHEET #: XX-XXXLGI HOMES NC, LLCJOSH SPIEGEL7201 CREEDMOOR ROADRALEIGH, NC 27612JOSH.SPIEGEL@LGIHOMES.COM(980) 722-0391NC Firm License #: P-17642537 E LYON STATION RD, STE 102(PHYSICAL)P.O.Box 361(MAILING)Creedmoor, NC 27522-0361chad@c3designeng.com919.625.7368 C-1.4 PRELIMINARY PLAT 50.00'UNSUITABLE SOILS UNSUITABLE SOILS UNSUITABLE SOILS UNSUITABLE SOILS 50.00'50.00' REGALWOOD (EXIST. SUBDIVISION) SHERMAN ROAD (SR#2211) EXIST. PUBLIC 50' ROW BAS S HOUND C IRC L E ( SR# 2 2 1 2 ) E X I ST . 5 0 ' PUB L I C ROW GREENFIELD SERENITY LLC PIN - 0655-13-8762.000 PID - 080655 0040 DB - 3632 : 0993 ZONED - RA-40 LAND USE - AGRICULTURAL ±44.0 AC JAMES B HOLLEMAN JR PIN - 0655-03-4488.000 PID - 080655 0036 DB - 3630 : 0342 ZONED - RA-40 LAND USE - AGRICULTURAL ±44.27 AC CHARLIE HICKS & C/O BEVERLY JOHNSON PIN - 0655-01-4436.000 PID - 080655 0046 DB - 212 : 0253 ZONED - RA-40 LAND USE - AGRICULTURAL ±92.00 AC REGALWOOD HOMEOWNERS ASSOC INC PIN - 0655-12-6991.000 PID - 080655 0030 44 DB - 1343 : 0382 ZONED - RA-40 LAND USE - AGRICULTURAL ±1.01 AC JOHN ANTHONY PICOLLA & BRENDA J PICOLLA PIN - 0655-12-6699.000 PID - 080655 0030 30 DB - 2953 : 0144 ZONED - RA-40 LAND USE - AGRICULTURAL ±0.71 AC JASON MCLAMB PIN - 0655-12-6586.000 PID - 080655 0030 31 DB - 3199 : 0335 ZONED - RA-40 LAND USE - AGRICULTURAL ±0.92 AC JENNIFER M RAGAN PIN - 0655-12-7458.000 PID - 080655 0030 32 DB - 3186 : 0078 ZONED - RA-40 LAND USE - AGRICULTURAL ±0.75 AC REGALWOOD HOMEOWNERS ASSOC INC PIN - 0655-12-7194.000 PID - 080655 0030 43 DB - 1343 : 0382 ZONED - RA-40 LAND USE - AGRICULTURAL ±3.26 AC SHERMAN RO A D 50' PUBLIC R O W ( S R # 2 2 1 1 )DAYDREAM CROSSING50' PUBLIC ROWCHANNEL DRIVE 50' PUBLIC ROW UNSUITABLE SOILS UNSUITABLE SOILS VICINITY MAP SITE N SITE INFORMATION CURRENT OWNER:LGI HOMES NC, LLC C/O JOSH SPIEGEL 7201 CREEDMOOR ROAD RALEIGH, NC 27612 PIN 0655-02-6490.000 PID 080655 0035 JURISDICTION: HARNETT COUNTY PLANNING TOWNSHIP:HECTORS CREEK COUNTY:HARNETT COUNTY STATE: NORTH CAROLINA FEMA FLOOD MAP:3720065500K & 3720064500J FEMA FLOOD ZONE:X RIVER BASIN:CAPE FEAR WATERSHED:BUIES CREEK (WSIV HIGH QUALITY) REFERENCES:DB 3635 / PG 0399 TOTAL PARCEL SIZE:±35.23 AC (±1,534,558 SF) CURRENT USE:VACANT / UNDEVELOPED PROPOSED USE:SINGLE FAMILY RESIDENTIAL SUBDIVISION LAND USE CLASS:AGRICULTURAL & RURAL RESIDENTIAL CURRENT ZONING: RA-40 REQUIRED STRUCTURE SETBACKS FRONT SETBACK:35' SIDE SETBACK: 10' CORNER SETBACK: 20' REAR SETBACK: 25' MIN. LOT WIDTH:100' MIN. LOT SIZE:28,000 SF MAX. DENSITY ALLOWED:2 UNITS / ACRE PROPOSED DENSITY:1.14 UNITS / ACRE (39 UNITS TOTAL) MAX. BUA ALLOWED:24% (368,294 SF) PROPOSED BUA: 22,274 SF (1.45%) - SIDEWALKS 119,399 SF (7.78%) - ROADS 40 SF (0.00%) - SIGNS 141,673 SF (9.23%) - TOTAL BUA REMAINING:14.77% (226,621 SF) (5,810 SF / LOT) REQUIRED OPEN SPACE:10% (153,456 SF / 3.52 AC) PROVIDED OPEN SPACE: 12.78% (196,172 SF / 4.50 AC) AVERAGE LOT SIZE:28,760 SF / 0.66 AC AREA OF NEW ROW:220,793 SF / 5.07 AC LINEAR FOOTAGE OF NEW ROADS:SHERMAN ROAD 1,981' DAYDREAM CROSSING 905' CHANNEL DRIVE 1,573' TOTAL: 4,459' PROPOSED WATER SUPPLY:HARNETT COUNTY PUBLIC UTILITIES PROPOSED SEWAGE TREATMENT: CONVENTIONAL SEPTIC SYSTEM CONTACT INFORMATION ENGINEER:C3 DESIGN & ENGINEERING, PLLC CHAD E. ABBOTT, PE 2537 E LYON STATION ROAD, SUITE 201 PO BOX 0361 CREEDMOOR, NC 27522 (919) 625-7368 SURVEYOR:MAULDIN - WATKINS SURVEYING, P.A. 1301 BROAD STREET PO BOX 444 FUQUAY-VARINA, NC 27526 (919) 552-9326 HASSIE KNOTT HEIRS C/O DOUGLAS E KNOTT PIN - 0655-21-8622.000 PID - 080655 0028 DB - 93E : 0340 ZONED - RA-40 LAND USE - AGRICULTURAL ±48.07 AC TYP. LOT DIAGRAM/LAYOUT → TO PINEY GROVE RAWLS ROAD PAVEMENT 1/4" / FT 1/4" / FT 50' RIGHT OF WAY 22'-0" 8" ABC 2" SF 9.5B ELECTRIC, CABLE, AND TELEPHONE TO BE LOCATED IN THE SHOULDER PUBLIC WATER LINE NATURAL GAS LINE TO BE LOCATED IN THE SHOULDER 3' MIN. STREET LIGHT (TYP.) DECIDUOUS STREET TREE (TYP. 1/50LF BOTH SIDES) (PER FINAL PLANTING PLAN) MIN. 5' FROM ROW MAX. 10' FROM ROW MIN. 8' FROM STREET LIGHT TYP. ROAD CROSS SECTION CORNER LOT 28,000 SF MIN. 100' MIN. LOT WIDTH 35' MIN. FRONT SETBACK 20' MIN. CORNER SETBACK 25' MIN. REAR SETBACK 10' MIN. SIDE SETBACK 10' MIN 100' MIN. STREET 35' MIN. 25' MIN. 20' MIN 10' MIN 100' MIN. STREET 35' MIN. 25' MIN. 10' MIN STREETSTANDARD LOT 28,000 SF MIN. 100' MIN. LOT WIDTH 35' MIN. FRONT SETBACK 25' MIN. REAR SETBACK 10' MIN. SIDE SETBACK 2% MAX. 11.5' SHOULDER 2.5' CURB & GUTTER 2:1 M A X 2:1 MA X 2% MAX. SIDEWALK 5' 3.5' SHOULDER 2.5' CURB & GUTTER 2:1 MA X 2:1 M A X HENRY D RAWLS PIN - 0645-82-8633.000 PID - 080655 0034 DB - 323 : 0050 ZONED - RA-40 LAND USE - AGRICULTURAL ±253.70 AC CONCRETE PAD W/ CURB RAMP FOR MAIL KIOSK (REFER TO NCDOT DETAIL - FIGURE 3 - CBU PLACEMENT FOR C&G SECTION RESIDENTIAL SUBDIVISION STREETS CUL-DE-SAC) NOTES & CONDITIONS OF APPROVAL: 1.THIS IS A PRELIMINARY PLAT, AND NOT TO BE USED TO TRANSFER PROPERTY. 2.ROAD NAMES TO BE APPROVED BY HARNETT COUNTY. 3.STREET LIGHTS SHALL BE IN INTERVALS OF NO MORE THAN 300'. 4.FIRE HYDRANTS SHALL BE SPACED AT A MAXIMUM OF 500' OF EACH OTHER. 5.EROSION & SEDIMENT CONTROL AND STORMWATER PERMIT WILL BE ACQUIRED AT TIME OF CONSTRUCTION PLAN APPROVAL. 6.THERE SHALL BE NO UNPERMITTED DISTURBANCES WITHIN WETLAND AREAS. 7.WATER SERVICE SHALL NOT BE INTERRUPTED TO EXISTING CUSTOMERS. 8.TOPOGRAPHIC DATA SHOWN IS FROM HARNETT COUNTY GIS. 9.THE HOA SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THE MAIL KIOSK UNIT AND CONCRETE PAD. 10.A FOUNDATION SURVEY WILL BE REQUIRED FOR EACH LOT. 11.THIS SUBDIVISION WAS PLANNED USING THE COMPATIBILITY DESIGN CONCEPT. 12.THIS PROJECT LIES WITHIN THE WSIV HIGH QUALITY WATERS CLASS. 13.EACH LOT WILL HAVE A MAXIMUM ALLOWABLE IMPERVIOUS AREA (BUA) ALLOWED. SEE SITE INFORMATION TABLE. 14.THIS DEVELOPMENT IS WITHIN ONE MILE OF A VOLUNTARY AGRICULTURAL DISTRICT. 15.APPROVAL OF THIS PLAT/PLAN DOES NOT GUARANTEE WATER CAPACITY OR WASTEWATER CAPACITY. CURRENT/FUTURE CAPACITY MAY NOT BE AVAILABLE. THIS DEVELOPMENT MAY REQUIRE ADDITIONAL IMPROVEMENTS TO THE EXISTING WATER AND WASTEWATER SYSTEM TO MEET FUTURE WATER AND WASTEWATER DEMANDS PRIOR TO A PRELIMINARY PLAT, CONSTRUCTION PLAN AND/OR FINAL PLAT APPROVAL. 16.OPEN SPACE TO BE MAINTAINED BY HOA. 17.STREET TREES TO BE MAINTAINED BY HOA 18.FOLLOWING PRELIMINARY APPROVAL, CONSTRUCTION PLANS MUST BE SUBMITTED TO HCDPU WITH REVIEW FEES PAID WITH APPLICATIONS COMPLETED PRIOR TO REVIEW AND APPROVAL OF UTILITY EXTENSIONS. 19.SYSTEM DEVELOPMENT FEES MUST BE PAID IN ACCORDANCE WITH THE LATEST WATER AND SEWER USE ORDINANCE. 20.THE ENGINEER OF RECORD MUST SUBMIT TO HCDPU ENGINEERED UTILITY CONSTRUCTION PLANS, HYDRAULIC ANALYSIS, AND ASSOCIATED DOCUMENTS FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO NCDEQ. 21.THE WATER AND SEWER UTILITIES MUST BE INSTALLED IN ACCORDANCE WITH NCDEQ AND HCDPU STANDARDS AND SPECIFICATIONS. 22.THE ENGINEER OF RECORD MUST SUBMIT ALL REQUIRED ENGINEERING FINAL DOCUMENTS TO HJCDPU FOR REVIEW PRIOR TO HCDPU APPROVAL OF THE WATER AND SEWER EXTENSIONS IN ACCORDANCE WITH THE LATEST HARNETT COUNTY WATER AND SEWER USE ORDINANCE. 23.THE PROPOSED WATER AND SEWER MAINS THAT WILL SERVE THE PROPOSED SUBDIVISION MUST BE PERMITTED WITH NCDEQ, INSTALLED, INSPECTED, TESTED AND APPROVED BY HARNETT COUNTY DEPARTMENT OF PUBLIC UTILITIES (HCDPU) AND NCDENR BEFORE THE DEVELOPER CAN RECORD THE FINAL PLAT. 24.THE FINAL PLAT AND THE AS-BUILT RECORD DRAWINGS LOCATION OF UTILITIES SHOULD COINCIDE. THE AS-BUILT RECORD DRAWINGS AND PE CERTIFICATIONS MUST BE SUBMITTED TO HCDPU FOR REVIEW BEFORE THE FINAL PLAT CAN BE RECORDED. 25.THE DEVELOPER MUST PROVIDE HCDPU A COST STATEMENT INDICATING THE COST TO INSTALL THE UTILITIES (MATERIALS AND LABOR) THAT WILL SERVE THE SUBDIVISION. 26.THE DEVELOPER AND THE UTILITY CONTRACTOR MUST PROVIDE HCDPU WITH A ONE (1) YEAR WARRANTY ON THE WATER AND SANITARY SEWER SYSTEM IMPROVEMENTS INSTALLED TO SERVE THE LOTS IN THE PROPOSED SUBDIVISION. 27.PHASES OF THIS DEVELOPMENT MAY REQUIRE ADDITIONAL IMPROVEMENTS TO THE EXISTING WATER AND/OR SEWER SYSTEM TO MEET FUTURE WATER AND SEWER DEMANDS PRIOR TO PRELIMINARY AND/OR CONSTRUCTION PLAN APPROVAL. 28.IF GRAVITY SEWER IS MADE AVAILABLE THIS DEVELOPMENT MAY BE SUBJECT TO SECTION 6 OF THE UDO DISTANCE SPECIFICATION TO CONNECT. 29.THE HOA WILL BE RESPONSIBLE FOR MAINTAINING THE SIDEWALK. 30.ALL SIDEWALKS SHALL MEET THE REQUIREMENTS OF THE "AMERICANS WITH DISABILITIES ACT". AS THE OWNER OF RECORD, I HEREBY FORMALLY CONSENT TO THE PROPOSED DEVELOPMENT SHOWN ON THIS SITE PLAN AND ALL REGULATIONS AND REQUIREMENTS OF THE HARNETT COUNTY ORDINANCES. ___________________________________________________________________________________________________ OWNER SIGNATURE DATE 10' STREET TREE EASEMENT3' 10' STREET TREE EASEMENT 10' STREET TREE EASEMENT (TYP.) 10' STREET TREE EASEMENT (TYP.) 10' STREET TREE EASEMENT (TYP.) 10' STREET TREE EASEMENT (TYP.) AREA OF SOILS WITH 24" OR MORE OF PROVISIONALLY SUITABLE MATERIAL AREA OF SOILS WITH 24" OR MORE OF PROVISIONALLY SUITABLE MATERIAL SIDE VARIES STREET LIGHT (TYP.) SHERMAN ROA D ( S R # 2 2 1 1 )DAYDREAMCROSSINGCHANNEL DRIVE CONTRACTOR SHALL PLACE ADDRESS SIGN (43 HICKS LANE) AT ROAD/DRIVEWAY CONNECTION TO MAINTAIN ACCESS & DIRECT EMERGENCY RESPONSE TO EXISTING RESIDENCE TIE TO EXIST. EOP SOILS LEGEND AREAS CONTAIN SOILS WITH 30 INCHES OR MORE OF USABLE MATERIAL AND HAVE POTENTIAL FOR CONVENTIONAL, MODIFIED CONVENTIONAL, LPP OR ULTRA-SHALLOW CONVENTIONAL SEPTIC SYSTEMS. THERE MAY BE INCLUSION OF SOILS 24 - 29 INCHES TO A RESTRICTIVE HORIZON THAT WILL HAVE POTENTIAL FOR LPP SEPTIC SYSTEMS. AREAS OF SOILS WITH 24 INCHES OR MORE OF PROVISIONALLY SUITABLE MATERIAL WITH POTENTIAL FOR LPP AND ULTRA-SHALLOW CONVENTIONAL TYPE SEPTIC SYSTEMS. AREAS OF UNSUITABLE SOILS 180.00' EXISTI N G P O W E R EASM E N T 5' WATER LINE EASEMENT (TYP.) 5' WATER LINE EASEMENT (TYP.) 5' WATER LINE EASEMENT (TYP.) 5' WATER LINE EASEMENT (TYP.) 5' WATER LINE EASEMENT (TYP.) 10' STREET TREE EASEMENT (TYP.) (SR#2211) ( S R# 2 2 1 2 ) ( SR# 14 1 4 ) (SR#1415)J:\DD-PROJECTS\2018\18-034\CIVIL\Current Drawings\18-034_S.dwg, 10/30/2019 12:36:13 PM, kelly, DWG To PDF.pc3, 1:1