Loading...
FM AP REVIEW �— Harnett --)rm COUNTY 441._ taws.,sniasosammit HARNETT COUNTY EMERGENCY SERVICES Fire Marshal Division REVIEWED FOR CODE COMPLIANCE P.O.Box 370 Lillington,NC 27546 910-893-7580 (J6. (, 1t_t.Acc (0-14-18 CODE COMPLIANCE OFFICER DATE Application for Plan Review Y Application R 1 D - s —art'^'iy^ae� sq Date Received: . {1 S) 1 X Received By: �J.l5 Name of Project: Harnett County School V Physical Address of Pm ect: 2911 Harnett Central Rd. Angier NC 27501 Plans Submitted By: Hamett County School Project Phone: (910 /-893 4808 Contact Person/Address: Rodney Gregory 1500 South Main St. Contact Phone: (910 )_985. 1003 ( - Contractor's Name/lnfa: Harnett County School Contractor's Phone: (910 985 1003 • Plans that are submitted will be reviewed as quickly as possible with an average time of review between 7-10 working days. • Status cheeks may be conducted on plan reviews by visiting the website htto://hteweb.harsettort/Click2GovBP/Index.isQ or by calling the Harnett County Central Permitting Office(910493-4759),or the Harnett County Fire Marshal's Office(910493-7500). • Approved plans must be picked op from the Central Permitting Office and all fees paid before any required inspections can be conducted. Harnett ins COUNTY 1101: t^'+"^°�"n'°'^"°""" �F M> ...a...n.v. Plan Review, Inspection, and Permit Fees Application Number 18-50044286 $200.00 ❑ Explosive Material (90 Days) $ - $100.00 ❑ Explosive Materials (72 Hours) $ - $100.00 El Fireworks Public Display $ - $50.00 O Final Inspection $ 50.00 $35.00 +$2.00 per device El Fire Alarm Testing $ - $35.00 +$2.00 per nozzle El Fixed Fire Suppression $ - $75.00 El Insecticide Fog/Fumigation $ - $100.00 ❑ Pipe Test/UST/AGST $ - $50.00 2 Plans up to 5000 sq ft $ 50.00 $100.00 El Plans 5001 sq ft to 10,000 sq ft $ - $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ - $250.00 ❑ Plans 25,001 sq ft and over $ - $35.00 +2.00 per head ❑ Sprinkler Certification Test $ - $50.00 ❑ Standpipe Testing $ - 550.00 ❑ Special Assembly (ie.amusement buildings,carnivals,fairs) $ - D $75.00 Tents/Canopies/Air Supported Structure $ - $100.00 Tank Installation (charge for each tank) $ $100.00 ❑ Tank Removal (charge for each tank) $ - Total Devices/Heads $ - Total Cost S 100.00 Code Enforcement Official D. Banks Wallace 6/19/2018 Harnett u e r r * (FMS w- m aMnr +-�r/S-^ ^ nt Fire Marshal Division June 19, 2018 Rodney Gregory 1500 South Main Street Lillington,NC 27546 Re: Harnett County Schools Huts (Overhills; Triton; Harnett Central; Western Harnett) Application Numbers—18-50044284; 18-50044285; 18-50044286; 18-50044287 Mr. Gregory, Thank you for submitting the plans for the Harnett County School mobile classrooms. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 1003.2.11 Means of egress illumination. o The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied o The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits. • 906.1 Fire Extinguishers o Fire extinguishers shall be located as not to exceed 75' of travel distance to an extinguisher. o The fire extinguishers provided shall have a minimum rating of 2A10:BC and shall not be installed higher than 5 feet above the finished floor. -1(-4 Harnett c o u e r r ei-+-wi Snag Doperise • 404.2 Fire Safety and Evacuation Plans o An approved fire safety and evacuation plan shall be prepared,posted and maintained for Group E occupancies. • Fire Department Access o The fire department access shall extend to within 150 feet of all portions of the facility. o The fire department access road shall be of an unobstructed width of not less than 20 feet and shall have an unobstructed vertical clearance of not less the 13 feet 6 inches. • Notes o Please schedule all fire inspections with the Fire Marshal's Office. o 910-984-4003 Thank you again for submitting the plans for the mobile classrooms. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions,please do not hesitate to call this office Again,thank you and we look forward to working with you during the construction period! Sincerely, D.Banks Wallace Chief Deputy Fire Marshal